  • 7/29/2019 Yorkville YS115P - Owners Manual

    1/7

    YSYSYSYS----111115P15P15P15P200 WATT POWERED SOUND REINFORCEMENT CABINET

    Owner's ManualM a n u e l d e L ' U t i l i s t e u r

    o-ys115p mar 99

    PERFORMANCE

    SERIES

  • 7/29/2019 Yorkville YS115P - Owners Manual

    2/7

    INSTRUCTIONS PERTAINING TO A RISKOF FIRE, ELECTRIC SHOCK,OR INJURY TO PERSONS.

    CAUTION:TO REDUCE THE RISK OF ELECTRIC SHOCK, DO

    NOT REMOVE COVER (OR BACK).NO USER SERVICEABLE PARTS INSIDE.

    REFER SERVICING TO QUALIFIEDSERVICE PERSONNEL.

    Read Instructions:The Owners Manualshould be read and understoodbefore operation of your unit. Please, save theseinstructions for future reference.

    Packaging:Keep the box and packaging materials, in case the unitneeds to be returned for service.

    Warning:When using electric products, basic precautions shouldalways be followed, including the following:

    Power Sources:Your unit should be connected to a power source only of thevoltage specified in the owners manual or as marked on the unit.

    This unit has a polarized plug. Do not use with an extension cord orreceptacle unless the plug can be fully inserted. Precautions shouldbe taken so that the grounding scheme on the unit is not defeated.

    Hazards:Do not place this product on an unstable cart, stand, tripod, bracket ortable. The product may fall, causing serious personal injury and seriousdamage to the product. Use only with cart, stand, tripod, bracket, or tablerecommended by the manufacturer or sold with the product. Follow themanufacturers instructions when installing the product and use mountingaccessories recommended by the manufacturer.

    The apparatus should not be exposed to dripping or splashingwater; no objects filled with liquids should be placed on theapparatus.

    Terminals marked with the lightning bolt are hazardous live;the external wiring connected to these terminals require installationby an instructed person or the use of ready made leads or cords.

    No naked flame sources, such as lighted candles, should beplaced on the apparatus.

    Power Cord:The AC supply cord should be routed so that it is unlikely that it wi llbe damaged. If the AC supply cord is damaged DO NOTOPERATE THE UNIT.

    Service:The unit should be serviced only by qualified service personnel.

    INSTRUCTIONS RELATIVES AU RISQUEDE FEU, CHOC LECTRIQUE, OUBLESSURES AUX PERSONNES.

    AVIS:AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE,

    NENLEVEZ PAS LE COUVERT (OU LE PANNEAUARRIERE). NE CONTIENT AUCUNE PIECE REPARABLE

    PAR LUTILISATEUR.

    CONSULTEZ UN TECHNICIEN QUALIFIEPOUR LENTRETIENT.

    Veuillez lire le manuel:Il contient des informations qui devraient tres comprises avantlopration de votre appareil. Conservez S.V.P. ces instructionspour consultations ultrieures

    Emballage:Conservez la boite au cas ou lappareil devait treretourner pour rparation.

    Warning:Attention: Lors de lutilisation de produits lectrique,assurez-vous dadhrer des prcautions de basesincluant celle qui suivent:

    Alimentation:Lappareil ne doit tre branch qu une source dalimentation

    correspondant au voltage spcifi dans le manuel ou tel quindiqusur lappareil. Cet appareil est quip dune prise dalimentationpolarise. Ne pas utiliser cet appareil avec un cordon deraccordement moins quil soit possible dinsrer compltement lestrois lames. Des prcautions doivent tres prises afin deviter que lesystme de mise la terre de lappareil ne soit dsengag.

    Hazard:Ne pas placer cet appareil sur un chariot, un support, un trpied ou unetable instables. Lappareil pourrait tomber et blesser quelquun ou subir desdommages importants. Utiliser seulement un chariot, un support, un trpiedou une table recommands par le fabricant ou vendus avec le produit.Suivre les instructions du fabricant pour installer lappareil et utiliser lesaccessoires recommands par le fabricant.

    Il convient de ne pas placer sur lappareil de sources de flammesnues, telles que des bougies allumes.

    Lappeil ne doit pas tre expos des gouttements deau ou desclaboussures et quaucun objet rempli de liquide tel que des vases

    ne doit tre plac sur lappareil.Les dispositifs marqus dune symbole dclair sont des partiesdangereuses au toucher et que les cblages extrieurs connects ces dispositifs de connection extrieure doivent tre effectivs par unoprateur form ou en utilisant des cordons dj prpars.

    Cordon dalimentation:vitez dendommager le cordon dalimentation. NUTILISEZ PASLAPPAREIL si le cordon dalimentation est endommag.

    Service:Consultez un technicien qualifi pour l entretien de votre appareil.

    IMPORTANT SAFETY INSTRUCTIONS

    SAFE_V4.doc Version 4.0 02/11/99 11:54 AM

  • 7/29/2019 Yorkville YS115P - Owners Manual

    3/7

    INTRODUCTIONINTRODUCTIONINTRODUCTIONINTRODUCTION

    TheYS115P is a bi-amped powered full-range speaker designed to meet most any requirement. It projects200 watts of clear, full sound. Features of this product include a Mic input, two parallel 1/4" input jacks,Volume control, loudness switch, and a speaker/line input select switch. This three way cabinet isprotected against overcurrentand clippingvia non-switchable (built in) limiters.

    FEATURESFEATURESFEATURESFEATURES

    Line Level/Line Level/Line Level/Line Level/Speaker Input JacksSpeaker Input JacksSpeaker Input JacksSpeaker Input Jacks

    The two 1/4" jacks will accept eitherLine orSpeaker inputs. In most cases, the input will befrom another speaker source ,and therefore theInput Select Switch should be IN.

    Mic InputMic InputMic InputMic Input

    TheMic input will accept most microphones.The Input Select Switch must beOUT forLine Level Inputs. When a Mic is being used inconjunction with another source (music) throughthe 1/4" jacks, the output level from the othersource will automatically be attenuated.

    Loud SwitchLoud SwitchLoud SwitchLoud SwitchTheLoud switch, when pushed IN, activates alow-frequency boostwhen desired. This featureis automatically reduced at high volumes toprotect the speaker.

    Ground Lift SwitchGround Lift SwitchGround Lift SwitchGround Lift SwitchIf a hum, or buzz is detected from the speaker,try setting the switch to the GND LIFT position(OUTposition). The switch should otherwise beleft in the GND (IN position).

    Volume ControlVolume ControlVolume ControlVolume Control

    Set the Volume Control to the desired outputlevel. Start with a high Volume setting, with youmixer turned down. Then, further adjust themixer and YS115Ps Volumes for best results.Multiple YS115PsMultiple YS115PsMultiple YS115PsMultiple YS115Ps

    The parallelinput jacks allow many YS115Ps tobe connected in a string. There is no practical

    limit to the number of powered speakers that canbe connected together.

    Power SwitchPower SwitchPower SwitchPower Switch

    The unit can be turned on and off via the powerswitch that is indicated by Power ON green LEDat the rear of the unit.

  • 7/29/2019 Yorkville YS115P - Owners Manual

    4/7

    AmplifierAmplifierAmplifierAmplifier

    TheYS115P features two amplifiers, one for the high frequency tweeterand one for the woofer. TheYS115P is thermally protected. If the amplifiers heatsink is blocked in any way, the output will graduallyattenuate until it is thermally acceptable to the amplifier, otherwise it will continue to reduce power andeventually shut down. The amplifier, once cooled down, will turn back ON producing full power. The woofer

    is protected against overcurrent and clipping, should the amp sense that either condition exists, it will startto reduce the output momentarily and roll off the low-frequency response ranging from 80 Hz to 150 Hz .The loudness button is defeated automatically at high power outputs and does not need to be touched.

    Specifications

    Power Amplifier A > 50W , 8 ohms load, 2 cycle burst30 W continuous @ 1% THD

    Amplifier B > 200 W, 2.5 ohms load, 2 cycle burst180 W, continuous @ 1 % THD*the above data was taken with limiters disabled.

    Input Impedance

    1/4" inputs 80 kOhmsXLR 10 kOhms microphone input

    Sensitivity

    2 X 1/4" inputsinput select switch in/out 2 V rms/60 mVrms

    mic inputinput select switch out 8-10 mVrms

    low freq. Measurements were made @ 1.0 kHz with the gain control set to maximum.hi freq. Measurements were made @ 5.0 kHz with the gain control set to maximum.

    Frequency Response: 20 Hz to 20 kHz

    Speakers: 1 Eminence 15" 2.5 ohms 200 Watt woofer1 RCF N252XN 8 ohm 30 watt tweeter with a formed horn1 Leson 8 ohm 100 watt piezo tweeter

    Crossover: Active crossover @ 3.5 kHz.

    Weight: 58 lbs.Dimensions: 23.70" X 18.00" X 14.40" (H,W,D)

    60.20 X 45.70 X 36.57 cm

  • 7/29/2019 Yorkville YS115P - Owners Manual

    5/7

    INTRODUCTIONINTRODUCTIONINTRODUCTIONINTRODUCTIONLenceinte bi-amplifie, pleine gamme YS-115P a t conue pour satisfaire les exigences les plusdiverses. Avec ses 200 Watts de puissance, elle projette un son plein et clair. Elle est dote dentre pourmicrophone, de deux entres parallles , dun contrle de volume, dun commutateur dintensit sonore(loudness), et dun slecteur de niveau dentre haut-parleur / ligne. Les limiteurs intgrs protgentlenceinte des surcharges de courant et prviennent la distorsion.

    CARACTRISTIQUESCARACTRISTIQUESCARACTRISTIQUESCARACTRISTIQUESPrise dentre niveauPrise dentre niveauPrise dentre niveauPrise dentre niveauligne/ haut-parleurligne/ haut-parleurligne/ haut-parleurligne/ haut-parleurLes deux jacks accepterons des signaux de niveauligne ou de niveau haut-parleur. Dans la plupart descas, le signal sera achemin lenceinte partir dunautre haut-parleur. Le slecteur de niveau dentredevra donc tre en position enfonce.

    Entre pour microphoneEntre pour microphoneEntre pour microphoneEntre pour microphoneLa prise dentre pour microphone acceptera lessignaux provenant de la plupart des microphones. Leslecteur de niveau dentre doit tre en positionsortie pour signal dentre niveau ligne. Lorsquunmicrophone est utilis en conjonction avec une autresource de signal (musique), travers les jacks , leniveau de sortie de la source additionnelle sera

    automatiquement attnu.Commutateur LOUDCommutateur LOUDCommutateur LOUDCommutateur LOUDCe commutateur, lorsquenfonc (en position IN),amorce une accentuation des basses frquences.Cette accentuation est automatiquement diminuelorsque lappareil est utilis des niveaux levs defaon protger les haut-parleurs.

    Commutateur deCommutateur deCommutateur deCommutateur deRaccordement La MasseRaccordement La MasseRaccordement La MasseRaccordement La MasseSi le haut-parleur met un bourdonnement, essayezun rglage en position sortie (ground lift). Lecommutateur doit gnralement tre rgl en positionGND (pouss).

    Contrle de volumeContrle de volumeContrle de volumeContrle de volumeRglez le contrle de volume de faon obtenir leniveau de sortie dsir. Commencez avec un rglagelev sur la YS-115P et un rglage bas sur votremixeur. Faite ensuite les ajustements ncessairespour obtenir les rsultats voulus.

    Ensembles AvecEnsembles AvecEnsembles AvecEnsembles AvecPlusieurs YS-115PPlusieurs YS-115PPlusieurs YS-115PPlusieurs YS-115P

    Les jacks dentre parallles permettent de relierplusieurs YS-115P une mme source. Il ny aaucune restriction sur la quantit de YS-115Ppouvant tre reli ensemble.

    Commutateur DAlimentationCommutateur DAlimentationCommutateur DAlimentationCommutateur DAlimentationCe commutateur situ au panneau arrire, permetde mettre lappareil en marche. Une DEL verteaussi situe sur le panneau arrire, indique silappareil est en marche.

  • 7/29/2019 Yorkville YS115P - Owners Manual

    6/7

    AmplificateursAmplificateursAmplificateursAmplificateursLe YS-115P est dot de deux amplificateurs. Un pour le haut-parleur daigu, un pour le haut-parleur de grave.Si le dissipateur de chaleur de lamplificateur est obstru de quelque faon que ce soit, le niveau de sortie seragraduellement rduit jusqu ce lamplificateur ait atteint une temprature acceptable. Si la faute persiste, leniveau de sortie continuera de diminuer et lamplificateur cessera ventuellement de fonctionner. Aprs avoirrefroidit, lamplificateur se remettra en marche avec sa pleine puissance. Le haut-parleur de grave est protgdes surcharges de courant et de la distorsion. Si lamplificateur dtecte lun ou lautre, il rduira sa puissance

    de sortie temporairement, et lvera la pente dattnuation des frquences graves de 80Hz 150Hz. Lecommutateur LOUDNESS est automatiquement dsactiv lorsque lappareil est utilis des niveaux levset ne requiert aucun ajustement.

    Specifications

    Amplificateur de puissance A >50W, charge de 8 ohms, impulsion deux cycles30 W continue @ 1% DHT

    Amplificateur de puissance B > 200W, charge de 2.5 ohms, impulsion deux cycles180 W continue @ 1% DHT* linformation ci-dessus est prise avec les limiteurs dsengags.

    Impdance dentre

    Prises 80 K ohmsPrise XLR pour microphone 10 K ohms

    Sensibilit

    2 x prises slecteur de niveau dentre

    enfonc/sortie 2 V rms/60 mVrmsentre pour microphone

    slecteur de niveau dentre sortie 8-10 mVrms

    Mesures des frquences graves prisent avec 1 KHz et contrle de gain position maximum.Mesures des frquences aigus prisent avec 5 KHz et contrle de gain position maximum.

    Rponse en frquence: 20 Hz 20 kHz

    Haut-parleur: 1Eminence 15" 2.5 ohms200 Watts pour frquences graves

    1 RCF N252XN 8 ohm 30 watts pour frquences aigusavec trompe moule

    1 Leson 8 ohm 100 watt tweeter piezoFiltre sparateur: Actif @ 3.5 kHz.

    Poids: 58 livres

    Dimensions: 23.70" X 18.00" X 14.40" (H,L,P)60.20 X 45.70 X 36.57 cm

  • 7/29/2019 Yorkville YS115P - Owners Manual

    7/7

    U.S.A.

    Yorkville Sound Inc.4625 Witmer Industrial Estate

    Niagara Falls, New York14305 USA

    Voice: (716) 297-2920Fax: (716) 297-3689

    WORLD HEADQUARTERS

    CANADA

    Yorkville Sound550 Granite CourtPickering, Ontario

    L1W-3Y8 CANADA

    Voice: (905) 837-8481Fax: (905) 837-8746

    Quality and Innovation Since 1963Printed in Canada