AISC 360-10 TABLE N5.4-1 INSPECTION TASKS PRIOR TO WELDING AISC 360-10 TABLE N5.4-2 INSPECTION TASKS DURING WELDING AISC 360-10 TABLE N5.4-3 INSPECTION TASKS AFTER WELDING AISC 360-10 TABLE N5.6-1 INSPECTION TASKS PRIOR TO BOLTING AISC 360-10 TABLE N5.6-2 INSPECTION TASKS DURING BOLTING AISC 360-10 TABLE N5.6-3 INSPECTION TASKS AFTER BOLTING INSPECTION TASKS PRIOR TO WELDING WELDING PROCEDURE SPECIFICATIONS (WPSs) AVAILABLE MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE MATERIAL IDENTIFICATION (TYPE/GRADE) WELDER IDENTIFICATION SYSTEM FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY) JOINT PREPARATION DIMENSIONS (ALIGNMENT, GAPS AT ROOT) CLEANLINESS (CONDITION OF STEEL SURFACES) TACKING (TACK WELD QUALITY AND LOCATION) CONFIGURATION AND FINISH OF ACCESS HOLES FIT-UP OF FILLET WELDS DIMENSIONS (ALIGNMENT, GAPS AT ROOT) CLEANLINESS (CONDITION OF STEEL SURFACES) TACKING (TACK WELD QUALITY AND LOCATION) CHECK WELDING EQUIPMENT INSPECTION INTERVAL REQUIRED ON THIS PROJECT INSPECTION TASKS DURING WELDING USE OF QUALIFIED WELDERS CONTROL AND HANDLING OF WELDING CONSUMABLES PACKAGING EXPOSURE CONTROL NO WELDING OVER CRACKED TACK WELDS ENVIRONMENTAL CONDITIONS WIND SPEED WITHIN LIMITS PRECIPITATION AND TEMPERATURE WPS FOLLOWED SETTINGS ON WELDING EQUIPMENT TRAVEL SPEED SELECTED WELDING MATERIALS SHIELDING GAS TYPE/FLOW RATE PREHEAT APPLIED INTERPASS TEMPERATURE MAINTAINED (MIN/MAX) PROPER POSITION (F, V, H, OH) WELDING TECHNIQUES INTERPASS AND FINAL CLEANING EACH PASS WITHIN PROFILE LIMITATIONS EACH PASS MEETS QUALITY REQUIREMENTS INSPECTION INTERVAL REQUIRED ON THIS PROJECT 1 1 THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A JOINT OR MEMBER CAN BE IDENTIFIED. STAMPS, IF USED, SHALL BE THE LOW-STRESS TYPE. YES YES YES YES YES NO YES YES YES YES YES YES YES YES P P O O O O O O O O O O O O INSPECTION TASKS AFTER WELDING WELDS CLEANED SIZE, LENGTH AND LOCATION OF WELDS WELDS MEET VISUAL ACCEPTANCE CRITERIA CRACK PROHIBITION WELD/BASE-METAL FUSION CRATER CROSS SECTION WELD PROFILES WELD SIZE UNDERCUT POROSITY ARC STRIKES k-AREA BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED) REPAIR ACTIVITIES DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER INSPECTION INTERVAL REQUIRED ON THIS PROJECT YES YES YES YES YES YES YES YES O P P P P P P P 2 WHEN WELDING OF DOUBLE PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN PERFORMED IN THE k-AREA, VISUALLY INSPECT THE WEB k-AREA FOR CRACKS WITHIN 3" (75 mm) OF THE WELD. 2 INSPECTION TASKS PRIOR TO BOLTING MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS INSPECTION INTERVAL REQUIRED ON THIS PROJECT INSPECTION TASKS DURING BOLTING FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES AND WASHERS (IF REQUIRED) ARE POSITIONED AS REQUIRED INSPECTION INTERVAL REQUIRED ON THIS PROJECT YES YES YES YES YES YES YES YES YES YES YES O O O O O P O O O O O INSPECTION TASKS AFTER BOLTING DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS INSPECTION INTERVAL REQUIRED ON THIS PROJECT YES P O-OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT BE DELAYED PENDING THESE INSPECTIONS. P-PERFORM THESE TASKS FOR EACH WELDED JOINT OR MEMBER. OBSERVATION OF WELDING OPERATIONS AND VISUAL INSPECTION OF IN-PROCESS AND COMPLETED WELDS SHALL BE THE PRIMARY METHOD TO CONFIRM THAT THE MATERIALS, PROCEDURES AND WORKMANSHIP ARE IN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS. FOR STRUCTURAL STEEL, ALL PROVISIONS OF AWS D1.1/D1.1M SHALL APPLY. FOR STRUCTURES IN RISK CATEGORY III/IV (ASCE/SEI 7, TABLE 1.5-1), ULTRASONIC TESTING SHALL BE PERFORMED ON ALL COMPLETE-JOINT-PENETRATION GROOVE WELDS SUBJECT TO TRANSVERSELY APPLIED TENSION LOADING IN BUTT, T- AND CORNER JOINTS, IN MATERIALS 5 / 16 " (8 mm) THICK OR GREATER. FOR STRUCTURES IN RISK CATEGORY I/II (ASCE/SEI 7, TABLE 1.5-1), ULTRASONIC TESTING SHALL BE PERFORMED ON 10% OF COMPLETE-JOINT-PENETRATION GROOVE WELDS SUBJECT TO TRANSVERSELY APPLIED TENSION LOADING IN BUTT, T- AND CORNER JOINTS, IN MATERIALS 5 / 16 " (8 mm) THICK OR GREATER. THERMALLY CUT SURFACES OF ACCESS HOLES SHALL BE TESTED USING MAGNETIC PARTICLE TESTING OR PENETRANT TESTING WHEN THE FLANGE THICKNESS EXCEEDS 2" (50 mm) FOR ROLLED SHAPES, OR WHEN THE WEB THICKNESS EXCEEDS 2" (50mm) FOR BUILT-UP SHAPES. ANY CRACK SHALL BE DEEMED UNACCEPTABLE REGARDLESS OF SIZE OR LOCATION. ALL NONDESTRUCTIVE TESTING OF WELDED JOINTS SHALL BE DOCUMENTED. SEE AISC360-10 CHAPTER N FOR ADDITIONAL WELD INSPECTION REQUIREMENTS. SEE AISC360-10 CHAPTER N FOR ADDITIONAL BOLT INSPECTION REQUIREMENTS. INSPECTION SHALL OCCUR DURING THE PLACEMENT OF ANCHOR RODS AND OTHER EMBEDMENTS SUPPORTING STRUCTURAL STEEL FOR COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS, INCLUDING DIAMETER, GRADE, TYPE AND LENGTH OF THE ANCHOR ROD OR EMBEDDED ITEM, AND THE EXTENT OR DEPTH OF EMBEDMENT INTO THE CONCRETE. FABRICATED STEEL AND ERECTED STEEL FRAMES, AS APPROPRIATE, SHALL BE INSPECTED FOR COMPLIANCE WITH THE DETAILS SHOWN ON THE CONSTRUCTION DOCUMENTS, INCLUDING BRACES, STIFFENERS, MEMBER LOCATIONS AND PROPER JOINT DETAIL APPLICATION. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TPYE, BOLT LENGTH IF THREADS ARE TO EXCLUDED FROM SHEAR PLANE) PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER FASTENER COMPONENTS JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING OPERATION FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATING FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARD THE FREE EDGES ABBREVIATIONS -AT -AND -ANCHOR BOLT @ & AB -ALTERNATE -ARCHITECTURAL -BASEMENT -BEAM ALT BSMT BM -BLOCK -BOND BEAM BLK BD BM -BUILDING -CANTILEVER -CLEAR BLDG CANT CLR -COMPOSITE -CONCRETE -CONCRETE MASONRY UNIT -CONNECTION COMP CONC CMU CONN -BOTTOM BOT BRG -BEARING -DEAD LOAD -DEGREE D BRG DL ° -DIAMETER -DIMENSION -DRAWING'S -EACH DIM DWG'S EA -EACH FACE -EACH WAY -EAST -ELECTRICAL -ELEVATION E F E W E ELEC EL -ELEVATOR -EQUAL -EXTERIOR -FINISHED FLOOR ELEV EQ EXP JT EXT F FLR -DECK BEARING -EXPANSION JOINT LUMBER (SHAPE VARIES) PLYWOOD IN SECTION VENEER LUMBER LAMINATED IN SECTION WOOD BLOCKING STUD WALL IN PLAN/SECTION MATERIALS LEGEND FILL DIMENSION GRANULAR CONCRETE IN SECTION FILL COMPACTED STEEL IN SECTION RIGID INSULATION (SHAPE VARIES) STEEL STUDS MASONRY IN SECTION IN SECTION -DOWEL DWL IN SECTION VENEER LUMBER RIM BOARD IN SECTION LUMBER GLU-LAMINATED GROUT IN SECTION IN SECTION I-JOIST -ADDITIONAL ADD'L -CENTER LINE C L ARCH -COLUMN COL -CONSTRUCTION CONST -CONTROL JOINT -CONTINUOUS CONT -CONTRACTOR CONTR -DETAIL DET -FOOT FT -FOOTING FTG -FOUNDATION FDN -GALVANIZED GALV -GAUGE GA -GENERAL CONTRACTOR G C -GLUED LAMINATED LUMBER GLU-LAM -HIGH POINT -HOOK HS HP HK -INCH -INSULATION -JOINT -JOIST IN INSUL JNT JST -JOIST BEARING -KIPS (1,000 LBS. = 1 KIP) -LIGHT WEIGHT -LINTEL -LIVE LOAD JST BRG k L W LTL L L -LONG LEG HORIZONTAL -LONG LEG VERTICAL -MASONRY OPENING LLH LLV MAS M O -HEADED STUD -MASONRY -INTERIOR INT -HORIZONTAL HORIZ -MAXIMUM MAX -MECHANICAL MECH -MICRO LAMINATED LUMBER ML -MINIMUM MIN -MISCELLANEOUS MISC -NORTH N -NOMINAL -NOT TO SCALE NEC NOM NTS -ON CENTER -OPENING -PER -PLANK OC OPNG / PLK -PLATE -POST TENSION -POUND -POUNDS PER SQUARE FOOT -POUNDS PER SQUARE INCH P PT # PSF PSI -PRECAST -REINFORCE -REVERSE -ROOF DRAIN P/C REINF REQ'D REV RD -NECESSARY -REQUIRED -OPPOSITE OPP -NUMBER # -SCHEDULE SCHED -SECTION SEC -SHEET SHT -SIMILAR SIM -CENTER TO CENTER CC -HOLLOW CORE PLANK H/C -MOMENT M LVL -LAMINATED VENEER LUMBER -SOUTH S -SQUARE SQ -STEEL -TEMPERATURE STD STL TEMP -TONGUE AND GROOVE -TOP AND BOTTOM -TOP OF PIER -TOP OF STEEL T&G T&B TOP TOS -TYPICAL -UNLESS NOTED OTHERWISE -VERTICAL -WELDED WIRE FABRIC -WEST TYP UNO VERT WWF W -STANDARD -TOP OF FOOTING TOFTG -THROUGH THRU -SPECIFICATION SPEC -TOP OF BEAM TOB -TOP OF CONCRETE TOC (E) -EXISTING -ROUGH SAWN RS -DEMOLITION DEMO -NOT IN CONTRACT NIC -TOP OF MASONRY TOM -FIELD VERIFY FV -GYPSUM BOARD GYP BD -BOARD BD -AMERICAN PLYWOOD APA ASSOCIATION -CHANNEL C -CAST IN PLACE CIP CONTR J GT -GIRDER TRUSS -HOLLOW STRUCTURAL SECTION HSS -MANUFACTURER MANF -OVER HEAD OH -POWDER ACTUATED FASTENER PAF -PLYWOOD PW -RADIUS R -TOP OF WALL TOW -STRUCTURAL ENGINEER OF RECORD SER -STAINLESS STEEL SS -WITH -WOOD W/ WD -PLUS OR MINUS ± -TRANSVERSE TRANS BITUMINOUS PAINT BELOW CONCRETE PAINT ALL STEEL WITH BIT -BITUMINOUS -BLOCKING BLKG -LONGITUDINAL LONGIT IN PLAN & SECTION DENOTES EXISTING -DRILLED PIER D P SPECIAL INSPECTION AND TESTING: 1. SPECIAL INSPECTION AND MINIMUM TESTING SHALL BE PERFORMED IN ACCORDANCE WITH 2012 IBC & ALL REFERENCED MATERIALS & TABLES. 2. INSPECTION SHALL BE PROVIDED BY AN INDEPENDENT TESTING AGENCY HIRED AT THE CONTRACTOR'S EXPENSE. AGENCY INSPECTION PERSONNEL SHALL MEET THE INSPECTOR QUALIFICATIONS FOR EACH MATERIAL ITEM AS INDICATED IN THE SPECIFICATIONS. INSPECTOR SHALL AT A MINIMUM: A) VERIFY ALL PIECES ARE FABRICATED CORRECTLY PRIOR TO ASSEMBLY. B) VISUALLY INSPECT ALL WELDS. C) PREPARE WRITTEN REPORTS OF INSPECTIONS. REPORTS SHALL BE PROVIDED TO OWNER'S REPRESENTATIVE WITHIN 72 HOURS OF INSPECTION. 3. ANY MATERIAL OR PLACEMENT DEVIATIONS FROM MINIMUMS SHOWN ON THE DRAWINGS OR IN SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. 4. IN ADDITION TO THE IBC INSPECTION TABLES, THE INSPECTOR SHALL VERIFY THAT ALL STEEL MAINTAIN ERECTION TOLERANCE OF STRUCTURAL STEEL AND ARCHITECTURALLY EXPOSED STRUCTURAL STEEL WITHIN AISC'S CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES. 5. TESTING - ANY FAILED FIELD TEST SHALL BE REPORTED TO ALBERTSON ENGINEERING INC IMMEDIATELY. STRUCTURAL NOTES: GENERAL NOTES: 1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND EXISTING FIELD CONDITIONS. PERFORM SITE OBSERVATIONS & MEASUREMENTS FOR OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. 2. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE AFFECTED PART OF THE WORK. 3. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING (AND ACCOMPANYING FOOTINGS), GUYS OR TIE-DOWNS. 4. ADDITIONAL OBSERVATIONS AS A RESULT OF REJECTION OF WORK COMPLETED AND/OR ADDITIONAL OBSERVATIONS DUE TO THE DEFICIENCIES IN WORK OBSERVED WILL BE AT THE EXPENSE OF THE CONTRACTOR. 5. ALL STRUCTURAL SHOP DRAWINGS TO BE REVIEWED BY JOB SUPERINTENDENT IN ADDITION TO ALL PERSONNEL DEEMED NECESSARY BY CONTRACTOR PRIOR TO SUBMITTAL TO ENGINEER FOR APPROVAL. 6. ALL SHOP DRAWING RESUBMITTALS SHALL INCLUDE A WRITTEN DETAILED LIST OF LOCATIONS AND DESCRIPTIONS OF ALL CHANGES MADE FROM PREVIOUS SUBMITTAL. LIST SHALL BE SPECIFIC AND GENERAL NOTE SUCH AS "DIMENSIONS CORRECTED" ARE NOT ACCEPTABLE. 7. ALL SHOP DRAWINGS TO BE REVIEWED BY ALBERTSON ENGINEERING INC. SHALL HAVE (2) HARD COPIES PROVIDED TO ALBERTSON ENGINEERING INC. FOR REVIEW. ONE MARKED SET OF THOSE DRAWINGS WILL BE RETURNED TO THE CONTRACTOR WHO WILL BE RESPONSIBLE FOR SCANNING IN ELECTRONICALLY AND PROVIDING FULL COLOR PDF ELECTRONIC FILES (OR OTHER APPROVED FILE TYPE) TO ALBERTSON ENGINEERING INC. ALBERTSON ENGINEERING INC. WILL NOT TRANSFER MARKS TO ANY ADDITIONAL COPIES OF THE SHOP DRAWINGS. COPIES OF THE MARKED UP COPIES SHALL BE USED FOR THE REMAINING PORTION OF THE SHOP DRAWING SUBMITTAL AND APPROVAL PROCESS. NO ADDITIONAL HARD COPIES OF THE SHOP DRAWINGS NEED TO BE PROVIDED TO ALBERTSON ENGINEERING INC., ALTHOUGH OTHER PARTIES MAY REQUIRE HARD COPIES OF THE MARKED UP DRAWINGS. THESE REQUIREMENTS ARE IN ADDITION TO THE TYPICAL PROJECT SHOP DRAWING SUBMITTAL REQUIREMENTS STATED IN THE PROJECT SPECIFICATIONS. 8. THE DESIGN OF THE STRUCTURE SHOWN IN THESE CONSTRUCTION DOCUMENTS IS FOR THE ONE-TIME USE AT THE SPECIFIC SITE REFERENCED IN THE DRAWINGS. DESIGN CODES: - 2012 INTERNATIONAL BUILDING CODE. PENETRATIONS: NO PENETRATIONS SHALL BE MADE IN ANY STRUCTURAL MEMBERS OTHER THAN THOSE LOCATED ON THESE DRAWINGS WITHOUT PREVIOUS APPROVAL OF THE ENGINEER. STRUCTURAL STEEL: 1. STEEL SHALL CONFORM TO ASTM A992 (Fy=50 KSI) FOR ALL W-SHAPES, AND ASTM A36 (Fy=36 KSI) FOR ALL OTHER MISCELLANEOUS SHAPES AND PLATES. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B (Fy=46 KSI). STRUCTURAL PIPE SHALL CONFORM TO ASTM A53, GRADE B, TYPE "E" OR "S" (Fy=35 KSI). 2. STEEL SHALL CONFORM TO THE LATEST EDITION OF "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDING" BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, INC. (AISC) AND TO THE AISC CODE OR STANDARD PRACTICE (LATEST EDITION). 3. ALL SHOP CONNECTIONS TO BE WELDED (UTILIZING E70XX ELECTRODES) AND FIELD CONNECTIONS TO BE BOLTED, UNLESS OTHERWISE NOTED. STEEL TO RECEIVE ONE SHOP COAT AND ONE FIELD TOUCH UP COAT OF APPROVED PAINT, EXCEPT WHERE GALVANIZED IS INDICATED ON THE DRAWINGS. 4. WELDS FOR ALL EXPOSED STRUCTURAL STEEL SHALL BE GROUND SMOOTH UNLESS NOTED OTHERWISE. 5. ALL BOLTED CONNECTIONS (UNLESS NOTED OTHERWISE) SHALL CONSIST OF 3/4" DIA. (MIN.) ASTM A325 HIGH STRENGTH BOLTS. ALL 3/4" DIA. BOLTS SHALL HAVE LOAD INDICATING SQUIRTER WASHERS. ADDITIONALLY PROVIDE BEVELED WASHERS AT CONNECTIONS TO CHANNEL FLANGES. 6. CONTRACTOR SHALL COMPLETELY FABRICATE ITEMS AT THEIR FACILITY. BOLTS MAY BE A307 FOR FIT-UP PURPOSES. ANY BOLTS USED IN THIS STAGE SHALL NOT BE USED IN FINAL ASSEMBLY IF THEY ARE TIGHTENED BEYOND SNUG TIGHT OR IN ANY OF THE PAIN FROM THE SQUIRTABLE WASHERS ESCAPES OR IS VISIBLE. 7. OWNER'S REPRESENTATIVES SHALL INSPECT ASSEMBLIES AT FABRICATOR'S YARD. NO WOK SHALL OCCUR UNTIL OWNER'S REPRESENTATIVES HAVE APPROVED SUCH STAGES. O F E I S S E T 6192 MICHAEL D. ALBERTSON E R U O S E T S I G D E R R P R E D A K H O T A E R O . N G . L A N O N G I N E Rapid C ity, South Da kota 57702 3202 W est Main Stre et 605.34 3.9606 Suite C Albertson Engineering Inc. SHEET TITL E: DATE: DRAWN BY : PROJECT N O.: DATE: NO. REVISIONS : DATE: NO. (E) SKIP MODIFICATIONS 6.16.2 015 2015-0 65 S0.0 STRU CTURAL NO TES, IBC TA BLES, MATE RIALS LEGE ND & ABBR EVIATIONS Sanford Underground Research Facility CA Yat es Ski p Modifications Lead, South Dakota 6.16.2015 8. STEEL SHALL BE FABRICATED TO TOLERANCES STATED IN AISC MANUAL OF STANDARD PRACTICE, EXCEPT LENGTHS SHALL BE WITHIN 1/16" OF LENGTH SHOWN. 9. PIECES NOT MADE TO CONFORM TO TOLERANCES SHALL BE DISCARDED. NO SPLICES OR ANY KIND SHALL BE PERMITED. 10. HANDRAILS, KICK PLATES & LANYARD TIE-OFFS SHALL BE PRIMED & PAINTED WITH A SAFTEY YELLOW COLOR PAINT. ALL OTHER STEEL SHALL BE PRIMED.

Upload: others

Post on 05-Feb-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Yates Skip Modifications Central ca

AISC 360-10 TABLE N5.4-1INSPECTION TASKS PRIOR TO WELDING

AISC 360-10 TABLE N5.4-2INSPECTION TASKS DURING WELDING

AISC 360-10 TABLE N5.4-3INSPECTION TASKS AFTER WELDING

AISC 360-10 TABLE N5.6-1INSPECTION TASKS PRIOR TO BOLTING

AISC 360-10 TABLE N5.6-2INSPECTION TASKS DURING BOLTING

AISC 360-10 TABLE N5.6-3INSPECTION TASKS AFTER BOLTING

INSPECTION TASKS PRIOR TO WELDING

WELDING PROCEDURE SPECIFICATIONS (WPSs) AVAILABLE

MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE

MATERIAL IDENTIFICATION (TYPE/GRADE)

WELDER IDENTIFICATION SYSTEM

FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY)

• JOINT PREPARATION

• DIMENSIONS (ALIGNMENT, GAPS AT ROOT)

• CLEANLINESS (CONDITION OF STEEL SURFACES)

• TACKING (TACK WELD QUALITY AND LOCATION)

CONFIGURATION AND FINISH OF ACCESS HOLES

FIT-UP OF FILLET WELDS

• DIMENSIONS (ALIGNMENT, GAPS AT ROOT)

• CLEANLINESS (CONDITION OF STEEL SURFACES)

• TACKING (TACK WELD QUALITY AND LOCATION)

CHECK WELDING EQUIPMENT

INSPECTIONINTERVAL

REQUIRED ON THISPROJECT

INSPECTION TASKS DURING WELDING

USE OF QUALIFIED WELDERS

CONTROL AND HANDLING OF WELDING CONSUMABLES

• PACKAGING

• EXPOSURE CONTROL

NO WELDING OVER CRACKED TACK WELDS

ENVIRONMENTAL CONDITIONS

• WIND SPEED WITHIN LIMITS

• PRECIPITATION AND TEMPERATURE

WPS FOLLOWED

• SETTINGS ON WELDING EQUIPMENT

• TRAVEL SPEED

• SELECTED WELDING MATERIALS

• SHIELDING GAS TYPE/FLOW RATE

• PREHEAT APPLIED

• INTERPASS TEMPERATURE MAINTAINED (MIN/MAX)

• PROPER POSITION (F, V, H, OH)

WELDING TECHNIQUES

• INTERPASS AND FINAL CLEANING

• EACH PASS WITHIN PROFILE LIMITATIONS

• EACH PASS MEETS QUALITY REQUIREMENTS

INSPECTIONINTERVAL

REQUIRED ON THISPROJECT

1

1 THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A JOINT OR MEMBER CAN BE IDENTIFIED. STAMPS, IF USED,SHALL BE THE LOW-STRESS TYPE.

YES

YES

YES

YES

YES

NO

YES

YES

YES

YES

YES

YES

YES

YES

P

P

O

O

O

O

O

O

O

O

O

O

O

O

INSPECTION TASKS AFTER WELDING

WELDS CLEANED

SIZE, LENGTH AND LOCATION OF WELDS

WELDS MEET VISUAL ACCEPTANCE CRITERIA

• CRACK PROHIBITION

• WELD/BASE-METAL FUSION

• CRATER CROSS SECTION

• WELD PROFILES

• WELD SIZE

• UNDERCUT

• POROSITY

ARC STRIKES

k-AREA

BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED)

REPAIR ACTIVITIES

DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER

INSPECTIONINTERVAL

REQUIRED ON THISPROJECT

YES

YES

YES

YES

YES

YES

YES

YES

O

P

P

P

P

P

P

P2 WHEN WELDING OF DOUBLE PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN PERFORMED IN THE k-AREA, VISUALLY INSPECT THE WEB k-AREA FOR CRACKS WITHIN 3" (75 mm)

OF THE WELD.

2

INSPECTION TASKS PRIOR TO BOLTING

MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS

INSPECTIONINTERVAL

REQUIRED ON THISPROJECT

INSPECTION TASKS DURING BOLTING

FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES ANDWASHERS (IF REQUIRED) ARE POSITIONED AS REQUIRED

INSPECTIONINTERVAL

REQUIRED ON THISPROJECT

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

O

O

O

O

O

P

O

O

O

O

O

INSPECTION TASKS AFTER BOLTING

DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS

INSPECTIONINTERVAL

REQUIRED ON THISPROJECT

YESP

• O-OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT BE DELAYED PENDING THESE INSPECTIONS.

P-PERFORM THESE TASKS FOR EACH WELDED JOINT OR MEMBER.

• OBSERVATION OF WELDING OPERATIONS AND VISUAL INSPECTION OF IN-PROCESS AND COMPLETED WELDS SHALL BE

THE PRIMARY METHOD TO CONFIRM THAT THE MATERIALS, PROCEDURES AND WORKMANSHIP ARE IN CONFORMANCE

WITH THE CONSTRUCTION DOCUMENTS.

• FOR STRUCTURAL STEEL, ALL PROVISIONS OF AWS D1.1/D1.1M SHALL APPLY.

• FOR STRUCTURES IN RISK CATEGORY III/IV (ASCE/SEI 7, TABLE 1.5-1), ULTRASONIC TESTING SHALL BE PERFORMED ON

ALL COMPLETE-JOINT-PENETRATION GROOVE WELDS SUBJECT TO TRANSVERSELY APPLIED TENSION LOADING IN

BUTT, T- AND CORNER JOINTS, IN MATERIALS 5/16" (8 mm) THICK OR GREATER.

• FOR STRUCTURES IN RISK CATEGORY I/II (ASCE/SEI 7, TABLE 1.5-1), ULTRASONIC TESTING SHALL BE PERFORMED ON

10% OF COMPLETE-JOINT-PENETRATION GROOVE WELDS SUBJECT TO TRANSVERSELY APPLIED TENSION LOADING IN

BUTT, T- AND CORNER JOINTS, IN MATERIALS 5/16" (8 mm) THICK OR GREATER.

• THERMALLY CUT SURFACES OF ACCESS HOLES SHALL BE TESTED USING MAGNETIC PARTICLE TESTING OR

PENETRANT TESTING WHEN THE FLANGE THICKNESS EXCEEDS 2" (50 mm) FOR ROLLED SHAPES, OR WHEN THE WEB

THICKNESS EXCEEDS 2" (50mm) FOR BUILT-UP SHAPES. ANY CRACK SHALL BE DEEMED UNACCEPTABLE REGARDLESS

OF SIZE OR LOCATION.

• ALL NONDESTRUCTIVE TESTING OF WELDED JOINTS SHALL BE DOCUMENTED.

• SEE AISC360-10 CHAPTER N FOR ADDITIONAL WELD INSPECTION REQUIREMENTS.

• SEE AISC360-10 CHAPTER N FOR ADDITIONAL BOLT INSPECTION REQUIREMENTS.

• INSPECTION SHALL OCCUR DURING THE PLACEMENT OF ANCHOR RODS AND OTHER EMBEDMENTS SUPPORTING

STRUCTURAL STEEL FOR COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS, INCLUDING DIAMETER, GRADE, TYPE

AND LENGTH OF THE ANCHOR ROD OR EMBEDDED ITEM, AND THE EXTENT OR DEPTH OF EMBEDMENT INTO THE

CONCRETE.

• FABRICATED STEEL AND ERECTED STEEL FRAMES, AS APPROPRIATE, SHALL BE INSPECTED FOR COMPLIANCE WITH

THE DETAILS SHOWN ON THE CONSTRUCTION DOCUMENTS, INCLUDING BRACES, STIFFENERS, MEMBER LOCATIONS AND

PROPER JOINT DETAIL APPLICATION.

FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS

PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TPYE, BOLTLENGTH IF THREADS ARE TO EXCLUDED FROM SHEAR PLANE)

PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL

CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACECONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLEREQUIREMENTS

PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNELOBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED

PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHERFASTENER COMPONENTS

JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONINGOPERATION

FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROMROTATING

FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSCSPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINTTOWARD THE FREE EDGES

ABBREVIATIONS

-AT

-AND

-ANCHOR BOLT

@

&

AB

-ALTERNATE

-ARCHITECTURAL

-BASEMENT

-BEAM

ALT

BSMT

BM

-BLOCK

-BOND BEAM

BLK

BD BM

-BUILDING

-CANTILEVER

-CLEAR

BLDG

CANT

CLR

-COMPOSITE

-CONCRETE

-CONCRETE MASONRY UNIT

-CONNECTION

COMP

CONC

CMU

CONN

-BOTTOMBOT

BRG -BEARING

-DEAD LOAD

-DEGREE

D BRG

DL

°

-DIAMETER

-DIMENSION

-DRAWING'S

-EACH

DIM

DWG'S

EA

-EACH FACE

-EACH WAY

-EAST

-ELECTRICAL

-ELEVATION

E F

E W

E

ELEC

EL

-ELEVATOR

-EQUAL

-EXTERIOR

-FINISHED FLOOR

ELEV

EQ

EXP JT

EXT

F FLR

-DECK BEARING

-EXPANSION JOINT

LUMBER

(SHAPE VARIES)PLYWOOD

IN SECTIONVENEER LUMBERLAMINATED

IN SECTION

WOODBLOCKING

STUD WALL INPLAN/SECTION

MATERIALS LEGEND

FILL

DIMENSION

GRANULAR

CONCRETEIN SECTION

FILL

COMPACTED

STEEL IN SECTION

RIGID INSULATION

(SHAPE VARIES)

STEEL STUDS

MASONRY IN SECTION

IN SECTION

-DOWELDWL

IN SECTIONVENEER LUMBERRIM BOARD

IN SECTIONLUMBERGLU-LAMINATED

GROUTIN SECTION

IN SECTIONI-JOIST

-ADDITIONALADD'L

-CENTER LINECL

ARCH

-COLUMNCOL

-CONSTRUCTIONCONST

-CONTROL JOINT

-CONTINUOUSCONT

-CONTRACTORCONTR

-DETAILDET

-FOOTFT

-FOOTINGFTG

-FOUNDATIONFDN

-GALVANIZEDGALV

-GAUGEGA

-GENERAL CONTRACTORG C

-GLUED LAMINATED LUMBERGLU-LAM

-HIGH POINT

-HOOK

HS

HP

HK

-INCH

-INSULATION

-JOINT

-JOIST

IN

INSUL

JNT

JST

-JOIST BEARING

-KIPS (1,000 LBS. = 1 KIP)

-LIGHT WEIGHT

-LINTEL

-LIVE LOAD

JST BRG

k

L W

LTL

L L

-LONG LEG HORIZONTAL

-LONG LEG VERTICAL

-MASONRY OPENING

LLH

LLV

MAS

M O

-HEADED STUD

-MASONRY

-INTERIORINT

-HORIZONTALHORIZ

-MAXIMUMMAX

-MECHANICALMECH

-MICRO LAMINATED LUMBERML

-MINIMUMMIN

-MISCELLANEOUSMISC

-NORTHN

-NOMINAL

-NOT TO SCALE

NEC

NOM

NTS

-ON CENTER

-OPENING

-PER

-PLANK

OC

OPNG

/

PLK

-PLATE

-POST TENSION

-POUND

-POUNDS PER SQUARE FOOT

-POUNDS PER SQUARE INCH

P

PT

#

PSF

PSI

-PRECAST

-REINFORCE

-REVERSE

-ROOF DRAIN

P/C

REINF

REQ'D

REV

RD

-NECESSARY

-REQUIRED

-OPPOSITEOPP

-NUMBER#

-SCHEDULESCHED

-SECTIONSEC

-SHEETSHT

-SIMILARSIM

-CENTER TO CENTERCC

-HOLLOW CORE PLANKH/C

-MOMENTM

LVL -LAMINATED VENEER LUMBER

-SOUTHS

-SQUARESQ

-STEEL

-TEMPERATURE

STD

STL

TEMP

-TONGUE AND GROOVE

-TOP AND BOTTOM

-TOP OF PIER

-TOP OF STEEL

T&G

T&B

TOP

TOS

-TYPICAL

-UNLESS NOTED OTHERWISE

-VERTICAL

-WELDED WIRE FABRIC

-WEST

TYP

UNO

VERT

WWF

W

-STANDARD

-TOP OF FOOTINGTOFTG

-THROUGHTHRU

-SPECIFICATIONSPEC

-TOP OF BEAMTOB

-TOP OF CONCRETETOC

(E) -EXISTING

-ROUGH SAWNRS

-DEMOLITIONDEMO

-NOT IN CONTRACTNIC

-TOP OF MASONRYTOM

-FIELD VERIFYFV

-GYPSUM BOARDGYP BD

-BOARDBD

-AMERICAN PLYWOODAPA

ASSOCIATION

-CHANNELC

-CAST IN PLACECIP

CONTR JGT -GIRDER TRUSS

-HOLLOW STRUCTURAL SECTIONHSS

-MANUFACTURERMANF

-OVER HEADOH

-POWDER ACTUATED FASTENERPAF

-PLYWOODPW

-RADIUSR

-TOP OF WALLTOW

-STRUCTURAL ENGINEER OF RECORDSER

-STAINLESS STEELSS

-WITH

-WOOD

W/

WD

-PLUS OR MINUS±

-TRANSVERSETRANS

BITUMINOUS PAINTBELOW CONCRETE

PAINT ALL STEEL WITH

BIT -BITUMINOUS

-BLOCKINGBLKG

-LONGITUDINALLONGIT

IN PLAN & SECTIONDENOTES EXISTING

-DRILLED PIERD P

SPECIAL INSPECTION AND TESTING:

1. SPECIAL INSPECTION AND MINIMUM TESTING SHALL BE PERFORMED INACCORDANCE WITH 2012 IBC & ALL REFERENCED MATERIALS & TABLES.

2. INSPECTION SHALL BE PROVIDED BY AN INDEPENDENT TESTING AGENCY HIRED ATTHE CONTRACTOR'S EXPENSE. AGENCY INSPECTION PERSONNEL SHALL MEET THEINSPECTOR QUALIFICATIONS FOR EACH MATERIAL ITEM AS INDICATED IN THESPECIFICATIONS.INSPECTOR SHALL AT A MINIMUM:A) VERIFY ALL PIECES ARE FABRICATED CORRECTLY PRIOR TO ASSEMBLY.B) VISUALLY INSPECT ALL WELDS.C) PREPARE WRITTEN REPORTS OF INSPECTIONS. REPORTS SHALL BE PROVIDED TOOWNER'S REPRESENTATIVE WITHIN 72 HOURS OF INSPECTION.

3. ANY MATERIAL OR PLACEMENT DEVIATIONS FROM MINIMUMS SHOWN ON THEDRAWINGS OR IN SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THEENGINEER.

4. IN ADDITION TO THE IBC INSPECTION TABLES, THE INSPECTOR SHALL VERIFYTHAT ALL STEEL MAINTAIN ERECTION TOLERANCE OF STRUCTURAL STEEL ANDARCHITECTURALLY EXPOSED STRUCTURAL STEEL WITHIN AISC'S CODE OFSTANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES.

5. TESTING - ANY FAILED FIELD TEST SHALL BE REPORTED TO ALBERTSONENGINEERING INC IMMEDIATELY.

STRUCTURAL NOTES:

GENERAL NOTES:

1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOBSPECIFICATIONS AND EXISTING FIELD CONDITIONS. PERFORM SITE OBSERVATIONS& MEASUREMENTS FOR OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS.

2. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. ANYDISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFOREPROCEEDING WITH THE AFFECTED PART OF THE WORK.

3. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THEBUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TODETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THEBUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OFNECESSARY SHORING, SHEETING, TEMPORARY BRACING (AND ACCOMPANYINGFOOTINGS), GUYS OR TIE-DOWNS.

4. ADDITIONAL OBSERVATIONS AS A RESULT OF REJECTION OF WORK COMPLETEDAND/OR ADDITIONAL OBSERVATIONS DUE TO THE DEFICIENCIES IN WORK OBSERVEDWILL BE AT THE EXPENSE OF THE CONTRACTOR.

5. ALL STRUCTURAL SHOP DRAWINGS TO BE REVIEWED BY JOB SUPERINTENDENT INADDITION TO ALL PERSONNEL DEEMED NECESSARY BY CONTRACTOR PRIOR TOSUBMITTAL TO ENGINEER FOR APPROVAL.

6. ALL SHOP DRAWING RESUBMITTALS SHALL INCLUDE A WRITTEN DETAILED LIST OFLOCATIONS AND DESCRIPTIONS OF ALL CHANGES MADE FROM PREVIOUS SUBMITTAL.LIST SHALL BE SPECIFIC AND GENERAL NOTE SUCH AS "DIMENSIONS CORRECTED" ARENOT ACCEPTABLE.

7. ALL SHOP DRAWINGS TO BE REVIEWED BY ALBERTSON ENGINEERING INC. SHALLHAVE (2) HARD COPIES PROVIDED TO ALBERTSON ENGINEERING INC. FOR REVIEW.ONE MARKED SET OF THOSE DRAWINGS WILL BE RETURNED TO THE CONTRACTOR WHOWILL BE RESPONSIBLE FOR SCANNING IN ELECTRONICALLY AND PROVIDING FULLCOLOR PDF ELECTRONIC FILES (OR OTHER APPROVED FILE TYPE) TO ALBERTSONENGINEERING INC. ALBERTSON ENGINEERING INC. WILL NOT TRANSFER MARKS TO ANYADDITIONAL COPIES OF THE SHOP DRAWINGS. COPIES OF THE MARKED UP COPIESSHALL BE USED FOR THE REMAINING PORTION OF THE SHOP DRAWING SUBMITTAL ANDAPPROVAL PROCESS. NO ADDITIONAL HARD COPIES OF THE SHOP DRAWINGS NEED TOBE PROVIDED TO ALBERTSON ENGINEERING INC., ALTHOUGH OTHER PARTIES MAYREQUIRE HARD COPIES OF THE MARKED UP DRAWINGS. THESE REQUIREMENTS ARE INADDITION TO THE TYPICAL PROJECT SHOP DRAWING SUBMITTAL REQUIREMENTSSTATED IN THE PROJECT SPECIFICATIONS.

8. THE DESIGN OF THE STRUCTURE SHOWN IN THESE CONSTRUCTION DOCUMENTS ISFOR THE ONE-TIME USE AT THE SPECIFIC SITE REFERENCED IN THE DRAWINGS.

DESIGN CODES:

- 2012 INTERNATIONAL BUILDING CODE.

PENETRATIONS:

NO PENETRATIONS SHALL BE MADE IN ANY STRUCTURAL MEMBERS OTHER THAN THOSELOCATED ON THESE DRAWINGS WITHOUT PREVIOUS APPROVAL OF THE ENGINEER.

STRUCTURAL STEEL:

1. STEEL SHALL CONFORM TO ASTM A992 (Fy=50 KSI) FOR ALL W-SHAPES, AND ASTMA36 (Fy=36 KSI) FOR ALL OTHER MISCELLANEOUS SHAPES AND PLATES. STRUCTURALTUBING SHALL CONFORM TO ASTM A500, GRADE B (Fy=46 KSI). STRUCTURAL PIPESHALL CONFORM TO ASTM A53, GRADE B, TYPE "E" OR "S" (Fy=35 KSI).

2. STEEL SHALL CONFORM TO THE LATEST EDITION OF "SPECIFICATION FOR THEDESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDING" BYTHE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, INC. (AISC) AND TO THE AISCCODE OR STANDARD PRACTICE (LATEST EDITION).

3. ALL SHOP CONNECTIONS TO BE WELDED (UTILIZING E70XX ELECTRODES) ANDFIELD CONNECTIONS TO BE BOLTED, UNLESS OTHERWISE NOTED. STEEL TORECEIVE ONE SHOP COAT AND ONE FIELD TOUCH UP COAT OF APPROVED PAINT,EXCEPT WHERE GALVANIZED IS INDICATED ON THE DRAWINGS.

4. WELDS FOR ALL EXPOSED STRUCTURAL STEEL SHALL BE GROUND SMOOTHUNLESS NOTED OTHERWISE.

5. ALL BOLTED CONNECTIONS (UNLESS NOTED OTHERWISE) SHALL CONSIST OF3/4" DIA. (MIN.) ASTM A325 HIGH STRENGTH BOLTS. ALL 3/4" DIA. BOLTS SHALLHAVE LOAD INDICATING SQUIRTER WASHERS. ADDITIONALLY PROVIDE BEVELEDWASHERS AT CONNECTIONS TO CHANNEL FLANGES.

6. CONTRACTOR SHALL COMPLETELY FABRICATE ITEMS AT THEIR FACILITY. BOLTSMAY BE A307 FOR FIT-UP PURPOSES. ANY BOLTS USED IN THIS STAGE SHALL NOTBE USED IN FINAL ASSEMBLY IF THEY ARE TIGHTENED BEYOND SNUG TIGHT OR INANY OF THE PAIN FROM THE SQUIRTABLE WASHERS ESCAPES OR IS VISIBLE.

7. OWNER'S REPRESENTATIVES SHALL INSPECT ASSEMBLIES AT FABRICATOR'SYARD. NO WOK SHALL OCCUR UNTIL OWNER'S REPRESENTATIVES HAVEAPPROVED SUCH STAGES.

OFE IS S

E

T

6192

MICHAEL D.

ALBERTSON

ER

UOS

ET

SI

G

D

ER R

PR

E

DA KHOT

A

ER

O. NG.

LA

NO

NGI N

E

Rapid

City, S

outh

Dakota

57702

32

02 W

est M

ain

Str

eet

60

5.3

43.9

60

6

Suite C

Alb

ert

son

Engin

eering Inc.

SH

EE

T T

ITLE

:D

AT

E:

DR

AW

N B

Y:

PR

OJE

CT

NO

.:

DA

TE

:N

O.

RE

VIS

ION

S:

DA

TE

:N

O.

(E) SKIP MODIFICATIONS

6.1

6.2

015

20

15-0

65

S0.0

ST

RU

CT

UR

AL N

OT

ES

, IB

C T

AB

LE

S,

MA

TE

RIA

LS

LE

GE

ND

& A

BB

RE

VIA

TIO

NS

Sanfo

rd U

nderg

round R

esearc

h F

acili

ty

CA

Yat e

s S

ki p

Modific

atio

ns

Lead, S

outh

Dakota

6.16.20158. STEEL SHALL BE FABRICATED TO TOLERANCES STATED IN AISC MANUAL OFSTANDARD PRACTICE, EXCEPT LENGTHS SHALL BE WITHIN 1/16" OF LENGTH SHOWN.

9. PIECES NOT MADE TO CONFORM TO TOLERANCES SHALL BE DISCARDED. NOSPLICES OR ANY KIND SHALL BE PERMITED.

10. HANDRAILS, KICK PLATES & LANYARD TIE-OFFS SHALL BE PRIMED & PAINTEDWITH A SAFTEY YELLOW COLOR PAINT. ALL OTHER STEEL SHALL BE PRIMED.

Page 2: Yates Skip Modifications Central ca

4' - 6 1/2"

5' -

0"

(E)C15X50

TOS 99' - 11 3/4"

(E)C15X50

TOS 99' - 11 3/4"

(E)C6X10.5

TOS 99' - 11 3/4"

(E)C6X10.5

TOS 99' - 11 3/4"

CL

EXISTING GUIDE RUNNERTYP

(E) 6"x6"x1/2" ANGLE - TYP

100'-0"

(E) STEEL DECK

(E)1/2" SIDEPLATE - TYP

NEW HSS 4"x4"x1/2" COLUMNW/ 8"x12"x3/8" CONNECTIONPLATE - CUT (E) STEEL PLATE- TYP

2

S2.0

1' - 9 1/4"1' - 9 1/4"

C L2

' - 0

"2

' - 0

"

4"x4"x1/2" ANGLE CONNECTIONFROM (E)C15x50 TO NEWMC12x40 - TYP

NEW MC12x40 W/ 3/8" ENDPLATES - TYP

B1C

A3

CA

4

B1

CA

3C

A4

C1

C2

C2

C1

CA

5C

A5

CA

5C

A5

(E)MC18X42.7

TOS 118' - 7 1/2"

(E)MC18X42.7TOS 118' - 7 1/2"

(E)C6X10.5

TOS 118' - 7 1/2"

(E)C6X10.5TOS 118' - 7 1/2"

EXISTING MOUNT FOR GUIDEROLLER TO BE REUSED - TYP

5' -

0"

4' - 6 1/2"

(E) DRAW-BAR - TYP

(E) GUIDE RUNNER - TYP

EXISTING THIMBLE & ROPE

CL

(E) RETAINER PLATE BELOW

(E) 6"x6"x1/2" ANGLE - TYP118'-7 3/4"

(E) STEEL DECK

(E) 1/2" SIDEPLATE - TYP

1

S2.0

NOTE:

- MC12x40 MATERIAL SHALLBE ASTM A572 GR50 ORAPPROVED EQUAL- ALL BOLTS TO BE A490N W/SQUIRTER D-11 WASHERS

NEW HSS 4"x4"x1/2" COLUMNW/ 8"x12"x3/8" CONNECTIONPLATE - TYP

4"x4"x1/2" ANGLE CONNECTIONFROM (E)MC18x42.7 TO NEWMC12x40 - TYP

NEW MC12x40 W/ 3/8" ENDPLATES - TYP

1' - 9 1/4"1' - 9 1/4"

C L2

' - 0

"2

' - 0

"

B1CA

1C

A2

B1

CA

1C

A2

C1

C2

C2

C1

CA

5C

A5

CA

5C

A5

NEW MC12x40 W/END PLATES

(E)6"x6"x1/2" CUT& REMOVED

NEW HSS 4"x4"x1/2" COLUMN

NEW MC12x40 W/END PLATES

MID DECK

LOWER DECK

UPPER DECK

2"x2"x1/4" ANGLE FOR RAIN SCREENTYP (4) LOCATIONS

RELOCATED & NEW TIE OFFS

SIDEPLATE, RUNNER & CONNECTIONANGLES REMOVED TO SHOW NEWCONNECTION

2"x2"x1/4" ANGLE FOR RAIN SCREENTYP (4) LOCATIONS

NEW MC12x40 W/ ENDPLATES - TYP

(E)6"x6"x1/2" - CUT &REMOVED

NEW HSS 4"x4"x1/2" COLUMNW/ 8"x12"x3/8" CONNECTIONPLATES - TYP

RELOCATED & NEW TIE OFFS

NEW MC12x40 W/ ENDPLATES - TYP

100'-0"100' - 0"

118'-7 3/4"118' - 7 3/4"

117'-1 1/2"117' - 1 1/2"

102'-1 1/2"102' - 1 1/2"

4 1

/4"

14

' - 0

"

1' -

6 1

/4"

15

' - 0

"2

' - 1

1/2

"

100'-0"100' - 0"

118'-7 3/4"118' - 7 3/4"

117'-1 1/2"117' - 1 1/2"

102'-1 1/2"102' - 1 1/2"

1' -

6 1

/4"

15

' - 0

"2

' - 1

1/2

"

14

' - 0

"

19

' - 4

3/4

"

2

S2.0

102'-1 1/2"

(E) WOOD DECK

NEW HSS 4"x4"x1/2" COLUMNTHRU CUT (E) WOOD DECK -TYP

(E) GUIDE RUNNERBELOW - TYP

(E) 6"x6"x1/2" ANGLE TO BECUT & REMOVED - TYP

CL

1' - 9 1/4" 1' - 9 1/4"

C L2

' - 0

"2

' - 0

"

C1

C2

C2

C1

OFE IS S

E

T

6192

MICHAEL D.

ALBERTSON

ER

UOS

ET

SI

G

D

ER R

PR

E

DA KHOT

A

ER

O. NG.

LA

NO

NGI N

E

Rapid

City, S

outh

Dakota

57702

3202 W

est M

ain

Str

eet

605.3

43.9

606

Suite C

Alb

ert

son

Engin

eering Inc.

SH

EE

T T

ITL

E:

DA

TE

:D

RA

WN

BY

:

PR

OJE

CT

NO

.:

DA

TE

:N

O.

RE

VIS

ION

S:

DA

TE

:N

O.

(E) SKIP MODIFICATIONS

6.1

6.2

015

2015-0

65

S1.0

LO

WE

R, M

ID &

UP

PE

R D

EC

K F

RA

MIN

GP

LA

NS

& IS

OM

ET

RIC

S

Sanfo

rd U

nderg

round R

esearc

h F

acili

ty

CA

Yate

s S

kip

Modific

ations

Lead, S

outh

Dakota

6.16.2015

1" = 1'-0"LOWER DECK FRAMING PLAN

1" = 1'-0"UPPER DECK FRAMING PLAN

ISOMETRIC 1 ISOMETRIC 2 3/8" = 1'-0"South

3/8" = 1'-0"West

1" = 1'-0"MID DECK FRAMING PLAN

Page 3: Yates Skip Modifications Central ca

LANYARD TIE-OFF(8) LOCATIONSSEE DETAILS ON THIS SHEET

118'-7 3/4"

TO PLATE

102'-1 1/2"

TO WD DECK

100'-0"

TO PLATE

CO

OR

DIN

AT

E H

EIG

HT

WIT

H S

HA

FT

SM

EN

8' -

6"

14

' - 0

"

10"

6' -

2"

CO

OR

DIN

AT

E H

EIG

HT

WIT

H S

HA

FT

SM

EN

8' -

2"

2"x2"x1/4" ANGLE FORRAIN SCREEN

(E)6"x6"x1/2" ANGLE TO BECUT & REMOVED

(E)1/2" STEEL SIDE PLATE

(E)C6x10.5 - TYP

(E)SKIP

(E)4"x3"x3/8" ANGLE TO REMAIN

102'-1 1/2"

TO WD DECK

100'-0"

TO PLATE

NEW HSS 4"x4"x1/2" COL - TYP

NEW MC12x40

BOLTS THRU PLATE,COLUMN & ANGLE TOBE SNUG TIGHT ONLY,NO SQUIRTERWASHERS - TYP

(E) DRAW-BAR

(E) THIMBLE & ROPE

(E) MOUNTS FOR GUIDEWHEELS TO BEREMOVED & RESET(WHEELS NOT SHOWN)

(E) GUIDE RUNNER

(E) 1/2" SIDE PLATE

(E) MC18x42.7

(E) RETAINING PLATE

NEW HSS 4"x4"x1/2"COLUMN W/ 8"x12"x3/8"CONNECTION PLATES

(E)C6x10.5 - SEE PLAN

(E) 1/4" STEEL PLATE

123'-3"

TO PLATE

NEW MC12x40 W/ 3/8"END PLATES - TYP

BOLTS THRU PLATE,COLUMN & ANGLE TOBE SNUG TIGHT ONLY,NO SQUIRTERWASHERS - TYP

(E) DRAW-BAR

(E) THIMBLE & ROPE

(E) MOUNTS FOR GUIDEWHEELS TO BEREMOVED & RESET(WHEELS NOT SHOWN)(E) GUIDE RUNNER

(E) SIDE PLATE

(E) MC18x42.7

(E) 6"x6"x1/2" ANGLE TO BECUT & REMOVED

(E) C6x10.5 - SEE PLAN

(E) 1/4" STEEL PLATE

118'-7 3/4"

TO PLATE

NEW HSS 4"x4"x1/2"COLUMN W/ 8"x12"x3/8"CONNECTION PLATE

NEW MC12x40 W/ 3/8"END PLATES - TYP

NEW 4"x4"x1/2"CONNECTION ANGLECOPE TO CHANNEL

(E) DRAW-BAR

(E) THIMBLE & ROPE

(E) MOUNTS FOR GUIDEWHEELS TO BEREMOVED & RESET(WHEELS NOT SHOWN)

(E) GUIDE RUNNER

(E) 1/2" SIDE PLATE

(E) MC18x42.7 - SEE PLAN

(E) RETAINING PLATE

(E)6"x6"x1/2" ANGLE TO BEREMOVED BELOW SIDEPLATE

(E) 1/4" STEEL PLATE

NEW MC12x40 W/4"x4"x1/2" CONNECTIONANGLES - TYP

DRILL 13/16"Ø HOLEIN (E)MC18x42.7 - TYP

CL

CL

7 1/2" 1' - 7 1/4" 1' - 7 1/4" 7 1/2"

CL

C LC L

C LC L4

1/2

"3

"3

"3

"4

1/2

" C LC L

C LC L 4

1/2

"3

"3

"3

"4

1/2

"

1 5/8"

3 1/8"1/4"

4"

1 3

/4"

7 3

/4"

9 1

/2"

R 1

3/4

"

1-1/16"Ø

5/8" STEEL PLATEW/ 1"Ø BOLT

1 1

/2"

6 1

/2"

1 1

/2"

9 1

/2"

1 1/4" 3" 1 1/4"

5 1/2"

13/16"Ø - TYP

5/8" STEEL PLATE W/(4) 3/4"Ø THRU BOLTS

5/16"

(E) C15x50

(E)6"x6"x1/2" ANGLE TO BEREMOVED TO TOP OFSIDEPLATE

(E) 1/4" STEEL PLATE

NEW MC12x40 W/4"x4"x1/2" CONNECTIONANGLES - TYP

(E) WOOD DECK

CL

CL

7 1/2" 1' - 7 1/4" 1' - 7 1/4" 7 1/2"

C LC L

C LC L

3 1

/4"

3"

3"

3"

2 3

/4"

CL

DRILL 13/16"Ø HOLEIN (E)C15x50 - TYP

C LC L

C LC L

3 1

/4"

3"

3"

3"

2 3

/4"

OFE IS S

E

T

6192

MICHAEL D.

ALBERTSON

ER

UOS

ET

SI

G

D

ER R

PR

E

DA KHOT

A

ER

O. NG.

LA

NO

NGI N

E

Rapid

City, S

outh

Dakota

57702

3202 W

est M

ain

Str

eet

605.3

43.9

606

Suite C

Alb

ert

son

Engin

eering Inc.

SH

EE

T T

ITL

E:

DA

TE

:D

RA

WN

BY

:

PR

OJE

CT

NO

.:

DA

TE

:N

O.

RE

VIS

ION

S:

DA

TE

:N

O.

(E) SKIP MODIFICATIONS

6.1

6.2

015

2015-0

65

S2.0

ELE

VA

TIO

NS

& S

EC

TIO

NS

Sanfo

rd U

nderg

round R

esearc

h F

acili

ty

CA

Yate

s S

kip

Modific

ations

Lead, S

outh

Dakota

6.16.2015

3/8" = 1'-0"OVERALL SKIP ELEVATION

3/4" = 1'-0"SIDE ELEVATION - YATES SKIP - LOWER DECK

3/4" = 1'-0"FRONT ELEVATION - YATES SKIP - UPPER DECK

3/4" = 1'-0"SIDE ELEVATION - YATES SKIP - UPPER DECK

3/4" = 1'-0"Section 1

Lanyard Tie-Off 3D View 3" = 1'-0"Lanyard Tie-Off Side View

3" = 1'-0"Lanyard Tie-Off Elevation 3/4" = 1'-0"

Section 2