xmass experiment for double beta decay

41
XMASS experiment for double beta decay K.Ueshima (ICRR) for XMASS collaboration June 11 @DBD07 in Osaka 1,Strategy of XMASS project 2,Design of detector for double beta decay 3,R&D status for double beta decay 4,800kg detector for Dark Matter search

Upload: others

Post on 03-May-2022

7 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: XMASS experiment for double beta decay

XMASS experiment for double beta decay

K.Ueshima (ICRR)for XMASS collaboration

June 11 @DBD07 in Osaka

1,Strategy of XMASS project2,Design of detector for double beta decay3,R&D status for double beta decay4,800kg detector for Dark Matter search

Page 2: XMASS experiment for double beta decay

Strategy of the XMASS project

~1 ton detector(FV 100kg)Dark matter searchLow BG at ~ keV

~20 ton detector(FV 10ton)Solar neutrinosDark matter search

Prototype detector(FV 3kg)

~2.5m~1m~30cm

Confirmation of feasibilities of the ~1ton detector

Double beta decay optionLow BG at ~ MeV

Page 3: XMASS experiment for double beta decay

Current target sensitivity of 0νββInverted hierarchy

The results of neutrino oscillation experiments suggest that the effective mass of neutrino is above 10meV if hierarchy is inverted.

Predicted half life with this effective mass ~ 1027-1028year

136Xe (N.A. 8.9%) is one of double beta nucleus.

10-4 10-3 10-2 10-1 1lightest neutrino mass in eV

10-4

10-3

10-2

10-1

1

|mee

| in

eV

99% CL (1 dof)

∆m232 > 0

disfavoured by 0ν2β

disfavouredby

cosmology

∆m232 < 0Inverted

〈〈〈〈mββββββββ〉〉〉〉 eV

10ton ( 136Xe natural)

or

1ton (enriched)

Morethan

Page 4: XMASS experiment for double beta decay

Large scintillation yield reduces2νββ background

Ultimate energy resolution is 0.6% @Q=2.5MeV since we have large scintillation yield (~42000photons/MeV).

0 1 2 3 4 5 6Resolution at 2.5 MeV (RMS)

1024

1025

1026

1027

1028

0 5 10 15 20 25 30lif

etim

e lim

it (9

5% C

.L.)

[yr]

resolution (at 100keV) [%]

from 1σ regionfrom 2σ regionfrom 3σ region

1- 3eV

0.1-0.3eV

0.01-0.03eV

1 – 3eV

0.1 –0.3eV

0.01 –0.03eV

10-2

10-1

100

101

102

103

104

0 500 100015002000250030003500

[cts

/keV

/5ye

ars/

10to

n]

[keV]

peak position

w/o smear 2% at 2.5 MeV 4% at 2.5 MeV 6% at 2.5 MeV

E resolution < 2% is needed for reducing 2 νββνββνββνββ BG .

Our goal

8x1021 year

10ton natural, 5 year

Signal region

2200 2400 2600keV

∆E=0.6%RMS

Page 5: XMASS experiment for double beta decay

Self shielding effect of liq. XeMany PMTs

10-12

10-11

10-10

10-9

10-8

10-7

10-6

10-5

10-4

10-3

10-2

10-1

0 500 1000 1500 2000 2500 3000energy (keV)

even

t rat

e (d

ru)

1 2 3

0νββνββνββνββT1/2=4x1027yr50keV RMS

23t 2.5m dia. Sphere

2.1mFV

1.9m FV10t

Large effect < 300keV

23ton liquid Xe detector BG spectrum

Low energy: attenuation for gamma rays are very large � realize low background

High energy: gamma rays penetrate liquid xenon easily � not enough for 0νββ exp.

Need a different design

Small effect

γγγγ rays from PMTs, rocks, etc. need to be shielded by other material

10-1

10-11

10-9

10-7

10-5

10-3

event rate cnt/day/keV/kg

2νββνββνββνββ

0

all volume

pp, 7Be

Page 6: XMASS experiment for double beta decay

Pure water

γγγγ

Scintillation light

mirror

Water shield & 136Xe in very low BG vessel

136Xe

Acrylic vessel

PMT

One solution for reducing BG

Room temperature, high pressure liquid Xe.

136Xe

Wave length shifter

Acrylic vessel

Page 7: XMASS experiment for double beta decay

Optics of the elliptic water tank

�ELliptic water Tank (ELT) detector has an interesting optical property.

�More than 90% of emitted photons can be collected to a single PMT.

Low BG, efficient light collection, and low cost detector !!!

PMT

1-(1-cos(28 deg.))/2 ~ 0.94

28°°°°

94%

photon come from left side

Page 8: XMASS experiment for double beta decay

Detector design and things to be solved

13m

4m

13m

Water

136Xe

PMTs

6.5m

5.3m

� Detector design to reach inverted hierarchy

Water shield and ELT reducegamma rays from rocks and PMTs.

• Background from vessel and WLS• Internal background• Attenuation of scintillation lights inside liquid xenon

• Dissolving contamination fromvessel

• …

We studied this method as one of our future plans.

Page 9: XMASS experiment for double beta decay

R&D to achieve good energy resolution

1. Measure photon yield of liquid Xe at room temperature.Small cell for liquid xenon at room temperature

2. Develop high efficiency wavelength shifterTPB doped polystyrene

3. Study ELT for collecting photon efficientlyMC simulation and prototype

136Xe

Wave length shifter

Acrylic vessel

Page 10: XMASS experiment for double beta decay

1. Measurement of light yield at room temperature.

We produced liquid Xe at 1degree, 5.5MPa

Piping for producing high pressure liquid Xe

Xe gas

Oxysorb

Small bottle

Cell

Page 11: XMASS experiment for double beta decay

Cell

Attached PMT Window

16mm

Liq.Xe16cc

flange attached PMT

Page 12: XMASS experiment for double beta decay

Outline 1degree,5.5MPa

-100degree,4.5MPa

-100degree,0.18MPa

Cool down liquid Xe temperature, measured temperature dependence

Reduce liquid Xe pressure, measured pressure dependence

Well known scintillation yield

Measurement of light yield at room temperature.

PMT

70mm

85mm

57Co

122keV γγγγ7.4kBq

16

Cell

MgF2

Liq.Xe

Compared

light guide window

Page 13: XMASS experiment for double beta decay

Measurement of light yield at room temperature and high pressure .

We measured and compared light yield of liquid Xeat 1degree and at -100degree.

Cool down Reduce Xe and make liquid Xe-100degree,0.18MPa

PMT

Cell

Page 14: XMASS experiment for double beta decay

Temperature dependence

1℃℃℃℃

5.5 MPa

33.8±±±±0.6p.e.

p.e.

counts/s

-100℃℃℃℃

4.5 MPa

39.8±±±±0.6p.e.

p.e.

counts/s1 ℃℃℃℃ 5.5MPa -100℃℃℃℃ 4.5MPa

57Co 122keV γγγγ

Page 15: XMASS experiment for double beta decay

Cell temperature ℃℃℃℃

Temperature dependence (@~ 5MPa)p.e. Mean of photoelectron

-100 ~ 1℃℃℃℃

16%difference

Page 16: XMASS experiment for double beta decay

Pressure dependence (@-100℃)

Xe pressure (MPa)

p.e.0.18 ~ 4.5MPa at -100℃℃℃℃

40±±±±2 p.e.

constant within 4%

Page 17: XMASS experiment for double beta decay

Results for scintillation yield

� Large light yield even at room temperature.

� pressure dependence

� temperature dependece

Room temp.-100degree

0.18MPa.4.5MPa 0.98±±±±0.02±±±±0.04

0.84±±±±0.02±±±±0.06

Page 18: XMASS experiment for double beta decay

2. Wavelength shifter

We have developed TPB doped polystyrene (PS) as WLS. High wavelength shift efficiency was measured by D.N.Mckinsey et.al. only for 75nm and 48nm (NIMB 132 (1997) 351-358)

We developed TPB doped in PS 0.5~4% and measured conversion efficiency for 175nm.

0.5% TPB doped PS, 100µm

Page 19: XMASS experiment for double beta decay

Wavelength shifter

WLS

Xe Excimer lamp 165~179nm

PMT

Monitor PMT

Beam splitter

Page 20: XMASS experiment for double beta decay

Result of conversion efficiency

0000

10101010

20202020

30303030

40404040

50505050

60606060

70707070

0000 1111 2222 3333 4444 5555

TPB 4% more than 50% efficiency for ~ 175nm .

efficiency %

TPB concentration %

Page 21: XMASS experiment for double beta decay

3. Prototype ELT

145

250

300

200mm

250

polished stainless steel

light source (136Xe)

Test photon collection efficiency.

Start to measure photon collection efficiency.

800mm

Page 22: XMASS experiment for double beta decay

Simulation of prototype ELT

8 inch 8 inch 8 inch 8 inch PMTPMTPMTPMTWater and LXe absorption and scattering. Reflection 80%

Photon collection efficiency 53% with a 8inch PMT is expected .

Generate photon at the light source (on φφφφ54mm sphere ).

Arrival position of photons on this plane

Photon distribution

Page 23: XMASS experiment for double beta decay

Current summary of R&D

� The photon yield of liquid Xe at room temperature is large.

� We developed TPB wave length shifter with an efficiency of 50%.

� Prototype ELT is being constructed.

35photon/keV ×2.5MeV×0.5(wavelength shifter eff.)×0.5(ELT photo

collection eff.)×0.25(PMT Q.E.) = 5400photoelectron

Assuming ~ 50% of ELT photon collection efficiency

Energy resolution due to photon statistics is 1.4% .

Meet our requirement.

Expected number of photoelectron at 0νββ

Page 24: XMASS experiment for double beta decay

800kg detector for Dark Matter search

� Budget funded this year.

� We are starting detail design of the detector.� Detector structure� Purification system� Cooling system� Electronics and etc…..

� Excavation for the detector site at Kamioka mine will start soon.

� Plan to finish the construction in two years and start measurement from 2009.

Page 25: XMASS experiment for double beta decay

� liquid Xe 800kg (FV 100kg)� Total 812 PMTs

� Photo coverage 67%� Diameter of LXe: 80cm

� Diameter of FV: 40cm� PMTs immersed in LXe

Structure of 800kg detector

80cm LXe(40cm FV)

Page 26: XMASS experiment for double beta decay

BG estimation

Water

Rock

n

γγγγ

PMT

γγγγ

μμμμ

liquid Xe

80cm

Detail simulation predicts <10-4 counts/day/kg/keV

� PMT gamma background� Reduced by self shielding

� External gamma� Reduced by water shield

� Neutron� Reduced by water shield

� Internal gamma/beta� Reduced by distillation

8m

8m

water

Page 27: XMASS experiment for double beta decay

Sensitivity of 800kg detector

~ factor 100 improvements expected

Plots except for XMASS: http://dmtools.berkeley.edu Gaitskell & Mandic

10-10

DAMA CRESTT

ZEPLIN1

CDMSIICRESTTII

ZEPLIN2

Edelweiss

Edelweiss2XENON100

SuperCDMSphase A

XMASS exposure 0.5 ton yrEth = 5 keVee, 3 σσσσ discovery

~10-45 cm2

DAMA CRESTT

ZEPLIN1CDMSII

Edelweiss

SuperCDMSphase AXMASS

WARP

XENON10

10-46

10-44

10-42

10-40

DM xsec for nucleon (cm2)

101 102 103

WIMP mass (GeV)

Page 28: XMASS experiment for double beta decay

Summary

� R&D for double beta decay has been performed. � Observed Light yield (35photon/keV) of liquid Xe at

room temperature. We developed TPB wavelength shifter (50% conversion efficiency) and made prototype ELT.

� We are going to start construction of 800kg detector for dark matter search which has sensitivity of 10-45 cm2 .

Page 29: XMASS experiment for double beta decay

Hex

1PMT12 pyramids / pentakisdodecahedron

5 triangles make pentagonal pyramid

34cm

31cm

31cm

10 PMTs per 1 triangle

1

2

3

4

5

6

7

8

9

10

agonalquarts window

HamamatsuR8778MOD

Structure of 800kg detector

Page 30: XMASS experiment for double beta decay

Distillation to reduce Kr (1/1000 by 1 pass)

� Very effective to reduce internal impurities (85Kr, etc.)

� We have processed our Xe before the measurement. 120KKr

165KXe

Boiling point (@1 atm)

~3m

13 stage of Operation: 2 atmProcessing speed: 0.6 kg / hourDesign factor: 1/1000 Kr / 1 pass

Lower temp.

Higher temp.

~1%

2cm φφφφ

~99%

Purified Xe:< 5 ppt Kr

(measured afterKr-enrichment)

Off gas Xe:330±100 ppb Kr(measured)

Original Xe:~3 ppb Kr

Page 31: XMASS experiment for double beta decay

Now (prototype detector) Goal (800kg detector)

� γ ray BG ~ 10-2 cpd/kg/keV 10-4 cpd/kg/keV→ Increase volume for self shielding→ Decrease radioactive impurities in PMTs (~1/10)

� 238U = (33±7)×10-14 g/g 1×10-14 g/g→ Remove by filter

� 232Th < 23×10-14 g/g (90% C.L.) 2×10-14 g/g→ Remove by filter (Only upper limit)

� Kr = 3.3±1.1 ppt 1 ppt→ Achieve by 2 purification pass

Very near to the target level!

1/100

1/33

1/12

1/3

Summary of BG measurement

Page 32: XMASS experiment for double beta decay

Acrylic vessel as high pressure vessel

Test vessel held 80 atm water!!

valve

110mm-dia.

120mm length

50mm-dia., 50mm length

~98cc

water

Need to test using high pressure liquid Xe(dissolution material)

Page 33: XMASS experiment for double beta decay

PMT

16

TPB4%

Cs137

Pb

Acrylic 40

LXe

液体液体液体液体キセノンキセノンキセノンキセノン中中中中でででで波長変換波長変換波長変換波長変換さささされたれたれたれた可視光可視光可視光可視光をををを検出検出検出検出

光電子数光電子数光電子数光電子数

Counts////sec

TPB+TPB+TPB+TPB+アクリルアクリルアクリルアクリル ありありありあり

605040302010

MC

Threshold

Counts////sec

Black DATA

red MC

TPBTPBTPBTPB

605040302010

Conversion efficiency 20 %%%%

p.e.

Page 34: XMASS experiment for double beta decay

low temp. high pressure

small cylinder don’t attach cooling plate

Cell tmp.is -100deg,but cylinder temp. is about 10deg. So liquid Xeis high pressure at -100deg.

Page 35: XMASS experiment for double beta decay

�PMT BG

Position resolution

Energy resolution

@10keV

@10keV

Fiducial volume

� Reconstruction of event� Key part for self shielding� Basic part is same as the

one confirmed in 100kg detector.

� Method� Make grid point at

every certain lengths.� Make the p.e. map for

all PMTs at the grid points.

� Use the event data and this map, calculate the event’s likelihood.

� Answer is the point which gives the maximum likelihood.

Page 36: XMASS experiment for double beta decay
Page 37: XMASS experiment for double beta decay

800kg chamber

Water shield tank

Experiment areaexcavation

20m

15m

15m

9m

8m

New excavation will be made in kamioka mine. ※Tentative design

Neutron/γγγγ are reduced>250cm water shield-fast neutron : 1/10000 for 2m shield-<500keV γγγγ : 1/10 for 50cm shield

Other similar scale experiment such as DBD will be ho used.

Page 38: XMASS experiment for double beta decay

�Estimation of gamma background from PMT

� One of the main BG source� Reconstruction of event position is crucial.� Activity of PMT

� PMT used in 100kg detector�

238U chain 1.8x10 -2 Bq/PMT�

232Th chain 6.9x10 -3 Bq/PMT�

60Co 5.5x10 -3 Bq/PMT�

40K 1.4x10 -1 Bq/PMT� PMT to be used in 800kg detector

�238U chain 1.8x10 -3 Bq/PMT

�232Th chain 6.9x10 -4 Bq/PMT

�60Co 5.5x10 -3 Bq/PMT

�40K 1.4x10 -2 Bq/PMT

Page 39: XMASS experiment for double beta decay

All volume 40cm Fiducial Volume35cm Fiducial Volume25cm Fiducial Volume

Estimated PMT BG

� Activity of PMT�

238U chain 1.8x10 -3 Bq/PMT�

232Th chain 6.9x10 -4 Bq/PMT�

60Co 5.5x10 -3 Bq/PMT�

40K 1.4x10 -2 Bq/PMT

� Below 300 keV number of events in the 25cm fiducialvolume(100kg) decreases rapidly

� Below 100 keV, BG becomes <10-5 counts/day/kg/keV.

Page 40: XMASS experiment for double beta decay

208Tl ~ Vessel BG estimation

±±±±2σσσσ

0.9%

10%

keV

keV

3.7××××10

171.9××××10 decay/5yr ××××1.4%

15

g/g

2.7××××10=

‐‐‐‐16Th

event

10%×0.05 = 0.5 %

0.9 + 0.5 = 1.4 %

Inner 86cm outer 106cm Sphere acrylic vessel

Page 41: XMASS experiment for double beta decay

Design and requirements for ~20meV

Outer cylindrical water tank: φφφφ13m, height 13m.

13m

4m

13m

Water

136Xe

PMTs

Distance btw 136Xe and PMTs: 4m.

Vessel: U,Th 10 ----16g/g.

6.5m

5.3m

1ton enriched 136Xe: φ φ φ φ 90cm acrylic vessel

� Detector design to achieve ~20meV sensitivity