© 2017 Xytronix Research and Design, Inc. Revision: 1.1 X-TC1W-K Thermocouple to 1-Wire Adapter 1. The sensor comes from the factory with a unique, non-changeable address. Once the sensor is connected to the host device, the device must associate a sensor name with the sensor address. Sensor Specifications: Thermocouple Sensor: Sensor Type: Type-K (Must be ungrounded or isolated) Temperature Range: -200°C to 1250°C (-328ºF to 2282ºF) Accuracy: ±0.5ºC X-TC1W-K: Operating Range: -40ºC to 80ºC (-40ºF to 180ºF) Humidity: 5-95%, non-condensing 1-Wire: Operating Voltage: +5.0 VDC ±0.25V Communications Protocol: 1-Wire® Installation Instructions: Install the X-TC1W-K Install the X-TC1W-K in a protected location away from rain and direct sunlight. The internal cold junction compen- sation will be more accurate if the X-TC1W-K is protected from rapid temperature changes. 1-Wire Connections The adapter has three wires which are connected to a compatible ControlByWeb device. The cable can be extended with additional wire, if needed. Quick Start Guide a division of Xytronix Research & Design, Inc. located in Nibley, Utah, USA Sensor Setup: 2. After the sensor is added, alarms, email notifications, logging and other options can be configured. For more information about how to configure these options, please consult the host device’s users manual. Thermocouple Sensor Connect the thermocouple sensor into the positve (+) and negative (-) terminals. (Connects to a supported ControlByWeb product) (Thermocouple sensor not included) +5V Data Gnd

Upload: others

Post on 23-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: X-TC1W-K guide v1.1-webRevision: 1.1 © 2017 Xytronix Research and Design, Inc. X-TC1W-K Thermocouple to 1-Wire Adapter 1. The sensor comes from the factory with a unique, non-changeable

© 2017 Xytronix Research and Design, Inc.Revision: 1.1

X-TC1W-KThermocouple to 1-Wire Adapter

1. The sensor comes from the factory with a unique, non-changeable address. Once the sensor is connected to the host device, the device must associate a sensor name with the sensor address.

Sensor Specifications:Thermocouple Sensor:Sensor Type: Type-K (Must be ungrounded or isolated)Temperature Range: -200°C to 1250°C (-328ºF to 2282ºF)Accuracy: ±0.5ºC

X-TC1W-K:Operating Range: -40ºC to 80ºC (-40ºF to 180ºF)Humidity: 5-95%, non-condensing

1-Wire:Operating Voltage: +5.0 VDC ±0.25VCommunications Protocol: 1-Wire®

Installation Instructions:Install the X-TC1W-KInstall the X-TC1W-K in a protected location away from rain and direct sunlight. The internal cold junction compen-sation will be more accurate if the X-TC1W-K is protected from rapid temperature changes.

1-Wire ConnectionsThe adapter has three wires which are connected to a compatible ControlByWeb device. The cable can be extended with additional wire, if needed.

Quick Start Guide

a division of Xytronix Research & Design, Inc. located in Nibley, Utah, USA

Sensor Setup:

2. After the sensor is added, alarms, email notifications, logging and other options can be configured. For more information about how to configure these options, please consult the host device’s users manual.

Thermocouple SensorConnect the thermocouple sensor into the positve (+) and negative (-) terminals.

(Connects to a supportedControlByWeb product)

(Thermocouple sensornot included)