www. fluidynefp · @ 1200 rpm, 100 psi 25v (q) 10 gpm ... pvt, pvs vpv racine/bosch rexroth...
TRANSCRIPT
FluiDyne VHO/VQCartridge KitsComplete Pumps
www . FluiDyneFP.com
• A technically advanced manufacturing facility.
• ISO Certified twelve production test stands –products are 100% tested prior to shipment.
• 18 month warranty on all products.
• Proprietary computer system to support customer service.
• 95% same or next day delivery.
Our People Make the Difference!
V i s i tw w w . F l u i D y n e F P. c o m
Em a i l : c s @ F l u i D y n e F P. c o m
• New application component selection
• Same day shipment
• 18 month warranty
• Advise on component repair and assembly
• Component failure analysis
• Massive local stock
Our people provide extensive support:
Our Promise: People Make the Difference
• Engineering expertise
• Decoding special part number
• Identification of parts within units
Our people provide extensive support:
FluiDyne supports the distributors providing local knowledge and assistance to fluid power customers.
SAMPLE CODE:
Single Pump Model Code
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7
25V(Q) 21 A 1 C 22 L
Series Designation25V (Q)35V (Q)45V (Q)
Table 1
--- Rated Capacity @ 1200 RPM, 100 PSI25V (Q)10 GPM (38 l/min.)12 GPM (45 l/min.)14 GPM (53l/min.)17 GPM (64 l/min.)21 GPM (79 l/min.)35V (Q)25 GPM (94 l/min.)30 GPM (113 l/min.)35 GPM (132 l/min.)38 GPM (143 l/min.)45V (Q)42 GPM (158 l/min.)50 GPM (189 l/min.)60 GPM (226 l/min.)
Table 2 Shaft Type*1- Straight Keyed (Standard)86- H.D. Straight Key11- SAE Splined
Table 4
Outlet PositionA – Outlet Opposite from InletB – Outlet 90 Counter Clockwise from InletC – Outlet in line with InletD – Outlet 90 Clockwise from Inlet
Table 5
Design Series Number
Table 6
Rotation (Viewed from shaft end)L- Left Hand RotationR- Right Hand Rotation (or omit)
Table 7
Port ConnectionsA-SAE 4 Bolt
Table 3
FluiDyne Fluid Power stock completecartridge kits, and/or seals, rotors,cam rings, valve plates, shafts,mountings, and housings for all sizesand configurations. In single, double,triple combinations. FluiDyne canconvert Caterpillar pump numbers toremanufactured Vickers or GenuineFluiDyne products. Extensive stockand support where and when youneed it.
SAMPLE CODE:
Double Pump Model Code
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7 TABLE 8
2520V(Q) 12 A 11 1 CC 22 L
Series Designation2520V (Q) 4520V (Q)3520V (Q) 4525V (Q)3525V (Q) 4535V (Q)
Table 1
Shaft End Pump Capacity Rated Capacity@ 1200 RPM, 100 PSI25V (Q)10 GPM (38 l/min.)12 GPM (45 l/min.)14 GPM (53 l/min.)17 GPM (64 l/min.)21 GPM (79 l/min.)35V (Q)25 GPM (94 l/min.)30 GPM (113 l/min.)35 GPM (132 l/min.)38 GPM (143 l/min.)
45V (Q)42 GPM (158 l/min.)50 GPM (189 l/min.)60 GPM (226 l/min.)
Table 2
Cover End Capacity @ 1200 RPM, 100 PSI**20V (Q) 2 GPM (7.6 l/min.)5 GPM (18.9 l/min.)8 GPM (30.2 l/min.)9 GPM (34 l/min.)11 GPM (41.5 l/min.)12 GPM (45 l/min.)14 GPM (53 l/min.)**25V (Q)12 GPM (45 l/min.)14 GPM (53 l/min.)17 GPM (64 l/min.)21 GPM (79 l/min.)
**35V (Q)25 GPM (94 l/min.)30 GPM (113 l/min.)35 GPM (132 l/min.)38 GPM (143 l/min.)
Table 4
Shaft Type (Single shaft seal pumps)*1- Straight Keyed (Standard)86- H.D. Straight Key11- SAE Splined
Table 5
Outlet Positions (Viewed from cover end of pump)
All series except 4535VWith No. 1 Outlet Opposite InletAA-No. 2 Outlet 135 CCW from InletAB-No.2 Outlet 45 CCW from InletAC-No.2 Outlet 45 CW from InletAD-No. 2 Outlet 135 CW from InletWith No. 1 Outlet 90 CCW from Inlet:BA-No.2 Outlet 135 CCW from InletBB-No.2 Outlet 45 CCW from InletBC-No.2 Outlet 45 CW from InletBD-No.2 Outlet 135 CW from InletWith No.1 Outlet inline with Inlet:CA-No.2 Outlet 135 CCW from InletCB-No.2 Outlet 45 CCW from InletCC-No.2 Outlet 45 CW from InletCD-No.2 Outlet 135 CW from InletWith No. 1 Outlet 90 CW from Inlet:DA-No.2 Outlet 135 CCW from InletDB-No.2 Outlet 45 CCW from InletDC-No.2 Outlet 45 CW from InletDD-No.2 Outlet 135 CW from InletSeries 4535VWith No. 1 Outlet Opposite InletAA-No.2 Outlet Opposite InletAB-No.2 Outlet 90 CCW from InletAC-No.2 Outlet Inline with InletAD-No.2 Outlet 90 CW from InletWith No. 1 Outlet 90 CCW from Inlet:BA-No.2 Outlet Opposite InletBB-No.2 Outlet 90 CCW from InletCC-No.2 Outlet Inline with InletDD-No.2 Outlet 90 CW from InletWith No.1 Outlet inline with Inlet:CA-No.2 Outlet Opposite InletCB-No.2 Outlet 90 CCW from InletCC-No.2 Outlet Inline with InletCD-No.2 Outlet 90 CW from InletWith No. 1 Outlet 90 CW from Inlet:DA-No.2 Outlet Opposite InletDB-No.2 Outlet 90 CCW from InletDC-No.2 Outlet Inline with InletDD-No.2 Outlet 90 CW from Inl
Table 6Design Series Number
Table 7
Rotation (Viewed from shaft end)L- Left Hand RotationR-Right Hand Rotation
(or omit)
Table 8
Table 3 SAE Port Connections
Code Inlet Out. #1 Out # 2 PumpShaft End Cover End Series
A 4-bolt Flg. 4-bolt flg. 4-bolt flg. All
C 4-bolt flg. SAE St. Thd. SAE St. Thd. 2520E 4-bolt flg. 4-bolt flg. SAE St. Thd. All except
4535
OUR PEOPLE
MAKE THE DIFFERENCE
OUR PEOPLE
MAKE THE DIFFERENCE
VHO / VQ Cart Kits
VHO / VQ Single, Double & Triple Pumps
30/35 Series35V2535V3035V3535V38
45 Series45V4245V5045V60
Industrial
20/25 Series20V0520V0820V1120V1220V1425V1225V1425V1725V21
30/35 Series30VQ2430VQ2835VQ2135VQ2535VQ3035VQ3535VQ38
45 Series45VQ4245VQ5045VQ6045VQ57
Mobile
20/25 Series20VQ0520VQ0820VQ1120VQ1220VQ1425VQ1225VQ1425VQ1925VQ21
Conversion capabilities available for many model types!
Sizes Available:FluiDyne New & Reman.• 20, 25, 30, 35, 45, 50 (V / VQ)
• 2520, 3520, 3525, 4520, 4525, 4535 (V / VQ)
Caterpillar Conversions
We can convert caterpillar pump numbers to remanufactured Vickers or Genuine FluiDyne products!
586.296.7200 • www.FluiDyneFP.com
Same Day Shipments
Supporting the channelsmeans shipping our high quality products to
the distributors and repair shops which provide local knowledge and assistance to the users
and builders of fluid power equipment.
PUMPS & MOTORS
VALVES
*Manufacturers names and numbers are for reference only
Square PumpsV10F, V10NF, V10P, V20F, V20NF, V20P
V10, V20, V2010, V2020
VHO / VQ Single, Double & Triple20, 25, 30, 35, 40, 45 (V/VQ)
2520, 2521, 3520, 3525, 4520, 4525, 4535 (V/VQ)
Cart Kits available for all sizes
*Caterpillar part numbered pumps also available
Round PumpsV104/5, V108/9, V110/1, V124/5, V128/9, V134/5
V144/5, V148/9, V350/3/6, V360/1/2, V368/9/70
VC108, 138, 148 Combination Pumps
VICKERS / EATON
Piston PumpsPVH 57, 74, 98, 131, 141
PVE 12, 19, 21, 27, 35, 47, 62
MotorsMHT 32, 50, 70, 90, 150, 250, 330, 440500, 660, 750, 1000
25M, 26M, 35M, 36M, 45M, 46M, 50M
M2-210
TransmissionsTA15, 19, 1919, 19V, 21
PSV 10, 15, 20, 25, 40
PSV 80, 100
PVF, PVQ, PVR
PVK, PVT, PVS
VPV
RACINE/BOSCH
REXROTHA10V(S)018
A10V(S)028, 45, 71, 100, 140
A4V(S)071, 125, 180, 250
DENISON
OILGEARPVW (W) (H) 06, 10, 15, 20, 34, 45, 60
Single T6, T7
Double T6, T67, T7
Triple T6, T67, T7
PV6, 10, 15, 20, 29
M4C, M4D, M4E
VELJANSingle VT6, VT7
Double VT6, VT67, VT7
Triple VT6, VT67, VT7
Drive Train VT6*R
VM4C, VM4D, VM4E
VM3B
CHAR-LYNNH SERIES (101-)
S SERIES (103-)
2000, 4000 (104-, 109-)
6000, 10,000 (112-, 119-)
J SERIES (129-)
DUMP PUMPSC101/102
EATONSAUER- DANFOSSWHITEPARKER/ROSS/TRW
INTERCHANGES WITH:
FluiDyne Remanufactured products Aftermarket Veljan
CG5
4CT, 4CG
DT8P1
Relief Valves
Check Valves
CT/CG/CS/CF 03, 06, 10Directional Valves
1/8 thru 1-1/2Needle Valves
X (C) G OR T 03, 06, 10Pressure Controls
Stack ModulesDGM Staks, Flow Control, Reliefs, Checks, Pressure Controls
FILTERS
FluiDyne has a full range of replacement filters elements and filter housings for:
Pall Hydac HyconSchroeder Vicker Parker
D03 – DG4V3, 4WE6
D05 – DG4S401, 4WE10
DG5V5, DG5S4, 4WEH10, 4WEH16
D08 - DG5S4, DG5S8, 4WEH25
DG17S/V 03, 05
DO3-5-7-8Valves and Stacks
31915 Groesbeck Highway • Fraser, Michigan 48026PH: 1-586-296-7200 • FAX: 1-586-296-7210 www.FluiDyneFP.com • Email: [email protected]
A n I S O 9 0 0 1 : 2 0 0 8 C o m p a n y6/2012