16
7/23/2019 Ww Replacementguide Low http://slidepdf.com/reader/full/ww-replacementguide-low 1/16 GRUNDFOS WASTEWATER GRUNDFOS A/S Poul Due Jensens Vej 7 DK-8850 Bjerringbro www.grundfos.com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence Pump comparison guide     9     6     5     8     1     4     7     0      0     6     0     5

Upload: hssingmec

Post on 17-Feb-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 1/16

GRUNDFOSWASTEWATER

GRUNDFOS A/SPoul Due Jensens Vej 7DK-8850 Bjerringbro

www.grundfos.com

Being responsible is our foundationThinking ahead makes it possible

Innovation is the essence

Pump comparison guide

    9    6    5    8    1    4    7    0     0

    6    0    5

Page 2: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 2/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Quick reference andconversion guide

This guide gives you an easy overview of which new Grundfos

pump to select when replacing a Grundfos AP pump, an older,

discontinued Grundfos S pump, or a pump manufactured by

Flygt, KSB or ABS.

The guide also includes product numbers for adaptors that allow

 you to t Grundfos pumps to existing auto-coupling systems.

Content:

Grundfos / Flygt............................................4 - 9

Grundfos / ABS ......................................... 10 - 15

Grundfos / KSB..........................................16 - 20

Grundfos / Grundfos S pumps..............20 - 23

Grundfos / Grundfos AP......... ................ 24 - 31

2 3

Page 3: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 3/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

0 4 8 12 16 20 24 28 32 36 Q [l/s]

0

2

4

6

8

10

12

14

H[m]

0 25 50 75 100 125 Q [m³/h]

3

4

1

2

1011

5   6 78

9

GRUNDFOS

FLYGT

 

Pump to be replaced Grundfos recommends

Flygt type Impeller no. Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

CP3067 HT 261 34 50 1.2 Single channel 5

CP3067 HT 263 34 50 1.2 Single channel 4

CP3085 HT 250 40x40 80 2.4 Single channel 7

CP3085 HT 252 40x40 80 2.4 Single channel 6

Flygt type Impeller no. Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

CP3085 LT 412 100 100 2 Single channel 11

CP3085 LT 414 80x100 100 1.3 Single channel 10

CP3085 MT 432 76 80 2 Single channel 9

CP3085 MT 434 76 80 1.3 Single channel 8

CP3085 MT 436 76 80 1.3 Single channel 7

CP3085 MT 438 64x86 80 1.3 Single channel 6

CP3085 MT 440 64x95 80 1.3 Single channel 5

Flygt type Impeller no. Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

CP3102 LT 410 55x100 150 3.1 2-channel 8

CP3102 LT 411 52x96 150 3.1 2-channel 7

CP3102 LT 412 54x88 150 3.1 2-channel 6

CP3102 LT 440 100 150 3.1 Single channel 5

CP3102 LT 441 100 150 3.1 Single channel 4

CP3102 LT 442 100 150 3.1 Single channel 3

Grundfos type Curve no. Adaptor

EF30.50.09.2 1 N/A

EF30.50.11.2 2 N/A

S E1 .50. 80. 22 .2 3 9 61 0576 5

S E1 .50. 80. 22 .2 3 9 61 0576 5

Grundfos type Curve no. Adaptor

S E1. 80.1 00.2 2. 4 4 9 6105 78 2

S E1. 80.1 00.1 5.4 3 9 6105 78 2

S E1. 80.8 0.2 2. 4 2 9 61 0576 5

S E1. 80.8 0.1 5.4 1 9 61 0576 5

S E1. 80.8 0.1 5.4 1 9 61 0576 5

S E1. 80.8 0.1 5.4 1 9 61 0576 5

S E1. 80.8 0.1 5.4 1 9 61 0576 5

Grundfos type Curve no. Adaptor

SE1.80. 10 0. 30 .4 2 96105787

SE1.80. 10 0. 30 .4 2 96105787

S E1 .8 0. 100. 22 .4 1 96 10578 7

SE1.80. 10 0. 30 .4 2 96105787

SE1.80. 10 0. 30 .4 2 96105787

S E1 .8 0. 100. 22 .4 1 96 10578 7

0 5 10 15 20 25 30 35 40 45 50 55 Q [l/s]

0

2

4

6

8

10

12

14

H[m]

0 25 50 75 100 125 150 175 200Q [m³/h]

2

1

34

56   7

8

GRUNDFOS

FLYGT

 

N/A: NOT AVAILABLE

4 5

0 2 4 6 8 10 12 14 16 18 20 Q [l/s]

0

4

8

12

16

20

24

H[m]

0 10 20 30 40 50 60   70   Q [m³/h]

3

672

1

4

5

GRUNDFOS

FLYGT

 

Page 4: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 4/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 5 10 15 20 25 30 35 40 45 Q [l/s]

0

4

8

12

16

20

24

28

32

H[m]

0 25 50 75 100 125 150 Q [m³/h]

11

12

978

10

5

6

1

432

GRUNDFOS

FLYGT

 

0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 60 6 5 7 0 Q [ l/ s]

0

4

8

12

16

20

24

H[m]

0 25 50 75 100 1 25 150 175 200 2 25 Q [m³/h]

7

65

8

9

3

4

21

GRUNDFOS

FLYGT

 

Flygt type Impeller no. Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

CP3102 MT 430 76 100 3.1 Single channel 10

CP3102 MT 432 76 100 3.1 Single channel 8

CP3102 MT 433 76 100 3.1 Single channel 7

CP3102 MT 435 76 100 3.1 Single channel 9

CP3102 HT 252 52 80 4.4 Single channel 12

CP3102 HT 254 46 80 4.4 Single channel 11

Flygt type Impeller no. Free passage Discharge P2 ( kW) I mpe ll er ty pe Curve no.

CP3126 MT 430 100x110 100 6.7 Single channel 9

CP3126 MT 432 87x100 100 5.3 Single channel 8

CP3126 HT 461 76 100 5.3 Single channel 6

CP3126 HT 462 76 100 5.3 Single channel 5

CP3126 HT 467 76 100 6.7 Single channel 7

Flygt type Impeller no. Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

CP3127 LT 410 76 150 5.9 2-channel 6

CP3127 LT 411 76 150 4.7 2-channel 5

CP3127 LT 412 76 150 4.7 2-channel 4

CP3127 LT 441 107x117 150 5.9 Single channel 8

CP3127 LT 442 100x110 150 4.7 Single channel 7

Grundfos type Curve no. Adaptor

SE1.80. 10 0. 40 .4 4 96105782

SE1.80. 10 0. 30 .4 3 96105782

S E1. 80.1 00. 22 .4 2 9 61 0578 2

S E1. 80.1 00. 15 .4 1 9 61 0578 2

S E1. 50. 80.4 0.2 6 96 10576 5

S E1. 50. 80.3 0. 2 5 96 10576 5

Grundfos type Curve no. Adaptor

SE1.100.100.75.4   4 96105782

SE1.100.100.55.4   3 96105782

SE1.80.100.55.4   2 96105782

SE1.80.100.40.4   1 96105782

SE1.80.100.55.4   2 96105782

G rund fos t yp e C urve no. Adaptor

SE1.100.150.75.4   3 96006638

SE1.100.150.55.4   2 96006638

SE1.100.150.40.4   1 96006638

SE1.100.150.75.4   3 96006638

SE1.100.150.55.4   2 96006638

0 10 20 30 40 50 60 70 80 90 Q [l/s]

0

2

4

6

8

10

12

14

16

18

20

H[m]

0 50 100 150 200 250 300 Q [m³/h]

7 8

4

5

61

2

3GRUNDFOS

FLYGT

 

6 7

Page 5: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 5/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 5 10 15 20 25 30 35 40 45 50 55 60 65 7 0 7 5 80 Q [ l/s]

0

2

4

68

10

12

14

16

18

20

H[m]

0 50 100 150 200 250 Q [m³/h]

10

9

8765

4

1

2

3   GRUNDFOS

FLYGT

 

0 5 10 15 20 25 30 35 40 45 50 55 Q [l/s]

0

4

8

12

16

20

24

H[m]

0 50 100 150 200Q [m³/h]

9

87

65   1   2

3

4

GRUNDFOS

FLYGT

 

Flygt type Impeller no. Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

CP3127 MT 430 100x110 150 5.9 Single channel 10

CP3127 MT 431 90x100 150 4.7 Single channel 8

CP3127 MT 432 87x100 150 4.7 Single channel 7

CP3127 MT 433 82x100 150 4.7 Single channel 6

CP3127 MT 434 80x100 150 4.7 Single channel 5

CP3127 MT 435 100 150 5.9 Single channel 9

CP3127 MT 436 100 150 4.7 Single channel 4

Flygt type Impeller no. Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

CP3127 HT 480 76 100 5.9 Single channel 9

CP3127 HT 481 76 100 5.9 Single channel 8

CP3127 HT 483 76 100 4.7 Single channel 7

CP3127 HT 484 76 100 4.7 Single channel 6

CP3127 HT 485 76 100 4.7 Single channel 5

Grundfos type Curve no. Adaptor

S E1. 80.1 00. 55. 4 3 9 6105 78 7

SE1.80. 10 0. 40 .4 2 96105787

SE1.80. 10 0. 40 .4 2 96105787

S E1. 80.1 00. 30. 4 1 9 6105 78 7

S E1. 80.1 00. 30. 4 1 9 6105 78 7

S E1. 80.1 00. 55. 4 3 9 6105 78 7

S E1. 80.1 00. 30. 4 1 9 6105 78 7

Grundfos type Curve no. Adaptor

S E1. 80.8 0. 75. 4 4 9 6105 79 0

S E1. 80.1 00. 55. 4 3 9 61 0578 2

S E1. 80.1 00. 55. 4 3 9 61 0578 2

SE1.80. 10 0. 40 .4 2 96105782

S E1. 80.1 00. 30. 4 1 9 61 0578 2

8 9

Page 6: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 6/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 1 2 3 4 5 6 7 8 9 Q [l/s]

0

10

20

30

40

50

60

70

H[m]

0 10 20 30 Q [m³/h]

6

52

3

4

111   12

13

7   8   9 10

GRUNDFOS

ABS

 

0 1 2 3 4 5 6 7 8 9 1 0 11 12 Q [l/s]

0

4

8

12

16

20

24

H[m]

0 10 20 30 40 Q [m³/h]

6

5

4

3

2

1

GRUNDFOS

ABS

 

ABS type Impeller Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

Piranha S12-2 Grinder - 1 1/4” 1.2 Grinder 7

Piranha S17-2 Grinder - 1 1/4” 1.7 Grinder 8

Piranha S21-2 Grinder - 1 1/4” 2.1 Grinder 9

Piranha S26-2 Grinder - 1 1/4” 2.6 Grinder 10

Piranha M55-2 Grinder - DN50 5.5 Grinder 11

Piranha M70-2 Grinder - DN50 7 Grinder 12

Piranha M85-2 Grinder - DN50 8.5 Grinder 13

ABS type Free passage Discharge P2 (kW) Impeller type Curve no.

AS 0530 M12-2 40 2” 1.2 Vortex 4

AS 0530 M17-2 40 2” 1.7 Vortex 5

AS 0530 M26-2 40 2” 2.6 Vortex 6

ABS type Free passage Discharge Pn Impeller type Curve no.

AS 0630 M10-4   60 DN65 1 Vortex 8

AS 0630 M13-4   60 DN65 1.3 Vortex 9

AS 0630 M22-4   60 DN65 2.2 Vortex 10

AS 0830 M10-4   60 DN80 1 Vortex 8AS 0830 M13-4   60 DN80 1.3 Vortex 9

AS 0830 M22-4   60 DN80 2.2 Vortex 10

AS 0840 M12-2   30 DN80 1.2 Contra Block 11

AS 0840 M17-2   3 0 DN80 1.7 Contra Block 12

AS 0840 M26-2   30 DN80 2.6 Contra Block 13

Grundfos type Curve no.

SEG.40.12.2 1

SEG.40.15.2 2

SEG.40.26.2 3

SEG.40.26.2 3

SEG.40.40.2 4APG.50.65.2 5

APG.50.92.2 6

Grundfos type Curve no.

EF30.50.09.2 1

EF30.50.11.2 2

EF30.50.15.2 3

Grundfos type Curve no.

SEV.65.65.09.2 1

SEV.65.65.11.2 2

SEV.65.65.22.2 5

SEV.65.65.09.2 1SEV.65.65.11.2 2

SEV.65.80.22.2 6

SE1.50.65.11.2 3

SE1.50.65.15.2 4

SE1.50.80.22.2 70 2 4 6 8 10 12 14 16 18 20 22 Q [l/s]

0

4

8

12

16

20

H[m]

0 10 20 30 40 50 60 70 80 Q [m³/h]

7

3   4

6

1

2

5

13

12

11

10

9

8

GRUNDFOS

ABS

 

Adaptors not available.

10 11

On ABS pumps with DIN anges the existing guide claw can be re-used on the Grundfos pump.

Page 7: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 7/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 4   8   12 16 20 24 28 32 Q [l/s]

0

4

8

12

16

20

24

28

H[m]

0 25 50 75 100 Q [m³/h]

6

45

3

2

1

GRUNDFOS

ABS

 

0 5 10 15 2 0 2 5 30 35 4 0 45   5 0 5 5 6 0 Q [ l/ s]

0

4

8

12

16

20

H[m]

0 25 50 75 100 125 150 175 200 Q [m³/h]

8

9

45

6

7

1   2

3

17

18

1415

161011

12 13

GRUNDFOS

ABS

 

ABS type Free passage Discharge P2 (kW) Impeller type Curve no.

AFP 0831 M30/4   80 DN80 3 Vortex 10

AFP 0831 M22/4   80 DN80 2.2 Vortex 9

AFP 0831 M15/4   80 DN80 1.5 Vortex 8

AFP 0831 M13/6   80 DN80 1.3 Vortex 7

AFP 0832 M70/2   80 DN80 7 Vortex 12

AFP 0832 M40/2   80 DN80 4 Vortex 11

AFP 0834 M110/2   80 DN80 11 Vortex 13

ABS type Free passage Discharge P2 (kW) Impeller type Curve no.

AFP 0841 M15/4 80 DN80 1.5 Contra Block 5

AFP 0841 M13/6 80 DN80 1.3 Contra Block 4

AFP 0842 M40/2 50 DN80 4 Contra Block 6

ABS type Free passage Discharge P2 (kW) Impeller type Curve no.

AFP 1031 M30/4 100 DN100 3 Vortex 13

AFP 1031 M22/4 100 DN100 2.2 Vortex 12

AFP 1031 M15/4 100 DN100 1.5 Vortex 11

AFP 1031 M13/6 100 DN100 1.3 Vortex 10AFP 1032 M90/4 100 DN100 9 Vortex 16

AFP 1032 M60/4 100 DN100 6 Vortex 16

AFP 1032 M40/4 100 DN100 4 Vortex 15

AFP 1032 M30/6 100 DN100 3 Vortex 14

AFP 1033 M110/4 100 DN100 11 Vortex 18

AFP 1033 M90/6 100 DN100 9 Vortex 17

Grundfos type Curve no.

SEV.80.80.22.4 3

SEV.80.80.22.4 3

SEV.80.80.15.4 2

SEV.80.80.11.4 1

SEV.80.80.60.2 5SEV.80.80.40.4 4

SEV.80.80.75.2 6

Grundfos type Curve no.

SE1.80.80.15.4 2

SEV.80.80.11.4 1

SE1.50.80.30.2 3

Grundfos type Curve no.

SEV.100.100.30.4 4

SEV.80.80.22.4 3

SEV.80.80.15.4 2

SEV.80.80.11.4 1SEV.100.100.75.4 7

SEV.100.100.55.4 6

SEV.100.100.40.4 5

SEV.100.100.30.4 4

SE1.100.100.75.4 9

SE1.100.100.40.4 8

0   4 8 12 16 20   24 28   32 Q [l/s]

0

5

10

15

20

25

30

35

H[m]

0 25 50 75 100 Q [m³/h]

7   8  910

11

12

13

1

6

2

3 4

5

GRUNDFOS

ABS

 

12 13

Page 8: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 8/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 5 10 15 20 25 30 35 40 45 50 55 Q [l/s]

0

4

8

12

16

20

H[m]

0 25 50 75 100 125 150 175 200Q [m³/h]

45

6

1  2   311

  12

13

14

7

8

9

10

GRUNDFOS

ABS

 

0   5 1 0 15 2 0   25 30 35   40 45 50 55 60 65 7 0 7 5 Q [ l/s]

0

5

10

15

2025

30

35

40

45

50

55

H[m]

0 2 5 5 0 75 1 00 1 2 5 1 50 17 5 2 00 2 25 2 50 Q [m ³/ h]

4

6

3

5

2

1

12

79

10

11

8

GRUNDFOSABS

 

0 10   20 30 40   50 60 70   8 0 9 0 1 00 Q [ l/ s]

0

4

8

12

16

20

24

H[m]

0 50 100 150 200 250 300 350 Q [m³/h]

1

2

3 5

4

10  11

67

8

9

GRUNDFOS

ABS

 

ABS type Free passage Discharge P2 (kW) Impeller type Curve no.

AFP 1041 M30/4 90 DN100 3 Contra Block 10

AFP 1041 M22/4 90 DN100 2.2 Contra Block 9

AFP 1041 M15/4 90 DN100 1.5 Contra Block 8

AFP 1041 M13/6 90 DN100 1.3 Contra Block 7

AFP 1042 M60/4 100 DN100 6 Contra Block 13AFP 1042 M40/4 100 DN100 4 Contra Block 12

AFP 1042 M90/4 100 DN100 9 Contra Block 14

AFP 1042 M30/6 100 DN100 3 Contra Block 11

ABS type Free passage Discharge P2 (kW) Impeller type Curve no.

AFP 1043 M70/2 55 DN100 7 Contra Block 8

AFP 1045 M185/4 100 DN100 18.5 Contra Block 11

AFP 1045 M160/4 100 DN100 16 Contra Block 10

AFP 1045 M110/4 100 DN100 11 Contra Block 9

AFP 1045 M90/6 100 DN100 9 Contra Block 7

AFP 1034 M200/2 75 DN100 20 Vortex 12

ABS type Free passage Discharge P2 (kW) Impeller type Curve no.

AFP 1541 M90/4 100 DN150 9 Contra Block 9

AFP 1541 M60/4 100 DN150 6 Contra Block 8

AFP 1541 M40/4 100 DN150 4 Contra Block 7

AFP 1541 M30/6 100 DN150 3 Contra Block 6

AFP 1543 M110/4 100 DN150 11 Contra Block 11

AFP 1543 M90/6 100 DN150 9 Contra Block 10

Grundfos type Curve no.

SE1.80.100.30.4 3

SE1.80.100.22.4 2

SE1.80.100.15.4 1

SE1.80.100.15.4 1

SE1.100.100.55.4 5SE1.100.100.40.4 4

SE1.100.100.75.4 6

SE1.80.100.22.4 2

Grundfos type Curve no.

S1 074 S 2

S1 224 H 5

S1 174 H 4

S1 134 H 3

SE1.100.100.75.4 1

SV 212 H 6

Grundfos type Curve no.

S1 124 BM 4

SE1.100.150.55.4 2

SE1.100.150.40.4 1

SE1.100.150.40.4 1S1 134 M 5

SE1.100.150.75.4 3

14 15

Page 9: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 9/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 2 4 6 8 10 12 14 16 Q [l/s]

0

4

8

12

16

20

24

28

H[m]

0 10 20 30 40 50 Q [m³/h]

1112

13

14

7

89

10

4   6

1

2

3

5

GRUNDFOS

KSB

 

0 2 4 6 8 10 12 14 16 18Q [l/s]

0

4

8

12

16

20

24

H[m]

0 10 20 30 40 50 60 Q [m³/h]

1 2 3

45

6

13

1415

16

78

9   1110   12

GRUNDFOS

KSB

 

KSB type Impeller Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

KRT F 40-250-4 150 25 DN50 4 Vortex 4

KRT F 40-250-4 160 25 DN50 4 Vortex 5

KRT F 40-250-4 170 25 DN50 4 Vortex 6

KRT F 40-250-4 180 25 DN50 4 Vortex 7

KRT F 40-250-4 190 25 DN50 4 Vortex 8

KSB type Impeller Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

KRT F 50-210-4 170 40 DN50 0.8 Vortex 7

KRT F 50-210-4 180 40 DN50 1.3 Vortex 8

KRT F 50-210-4 190 40 DN50 2.4 Vortex 9

KRT F 50-210-4 200 40 DN50 2.4 Vortex 10

KRT F 50-210-2 170 40 DN50 2.6 Vortex 11

KRT F 50-210-2 180 40 DN50 3.95 Vortex 12

KRT F 50-210-2 190 40 DN50 3.95 Vortex 13

KRT F 50-210-2 200 40 DN50 3.95 Vortex 14

KSB type Impeller Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

KRT F 65-210-4 140 65 DN65 0.8 Vortex 7

KRT F 65-210-4 157 65 DN65 0.8 Vortex 8

KRT F 65-210-4 175 65 DN65 1.3 Vortex 9

KRT F 65-210-4 185 65 DN65 1.3 Vortex 10

KRT F 65-210-4 190 65 DN65 2.4 Vortex 11

KRT F 65-210-4 195 65 DN65 2.4 Vortex 12

KRT F 65-210-2 115 65 DN65 2.1 Vortex 13

KRT F 65-210-2 120 65 DN65 2.1 Vortex 14

KRT F 65-210-2 130 65 DN65 2.6 Vortex 15

KRT F 65-210-2 140 65 DN65 3.95 Vortex 16

Grundfos type Curve no.

EF30.50.06.2 1

EF30.50.06.2 1

EF30.50.09.2 2

EF30.50.09.2 2

EF30.50.11.2 3

Grundfos type Curve no.

SEV.65.65.09.2 1

SEV.65.65.11.2 2

SEV.65.65.11.2 2

SEV.65.65.15.2 3

SEV.65.80.30.2 4

SEV.65.65.40.2 5

SEV.65.65.40.2 5

SEV.65.80.40.2 6

Grundfos type Curve no.

SEV.65.65.09.2 1

SEV.65.65.11.2 2

SEV.65.65.15.2 3

SEV.65.65.22.2 4SEV.65.65.22.2 4

SEV.65.65.22.2 4

SEV.65.65.22.2 4

SEV.65.65.22.2 4

SEV.65.65.30.2 5

SEV.65.65.40.2 6

0 1 2 3 4 5 6 7 8 9 1 0 11 12 Q [l/s]

0

2

4

6

8

10

12

14

16

18

20

H[m]

0 10 20 30 40 Q [m³/h]

54

6 7

8

1   2   3

GRUNDFOS

KSB

 

Adaptors not available.

16 17

Page 10: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 10/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 4 8 12 16 20 24 28 32 Q [l/s]

0

4

8

12

16

H[m]

0 20 40 60 80 100 120 Q [m³/h]

6   7 8   9  10

11

12 3

4

5   GRUNDFOS

KSB

 

0 10 20 30 40 50 60 70 80 90 Q [l/s]

0

5

10

15

20

25

30

H[m]

0 50 100 150 200 250 300 Q [m³/h]

4   32

1

5   6

7

8

GRUNDFOS

KSB

 

KSB type Impeller Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

KRT F 80-210-4 158 80 DN80 0.8 Vortex 6

KRT F 80-210-4 175 80 DN80 0.8 Vortex 7

KRT F 80-210-4 185 80 DN80 1.3 Vortex 8

KRT F 80-210-4 190 80 DN80 2.4 Vortex 9

KRT F 80-210-4 207 80 DN80 2.4 Vortex 10KRT F 80-210-4 210 80 DN80 3.15 Vortex 11

KSB type Impeller Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

KRT F 80-315-2   170 76 DN80 14.5 Vortex 8

KRT F 80-315-2   190 76 DN80 19 Vortex 9

KRT F 80-315-2   210 76 DN80 25 Vortex 10

KRT F 100-250-4   200 100 DN100 4 Vortex 6

KRT F 100-250-4   237 100 DN100 5.5 Vortex 7

KSB type Impeller Free passage Discharge P2 ( kW) I mpel le r t ype Curve no.

KRT E 80-250-4 225 76 DN80 5.5 Single channel 5

KRT E 80-250-4 240 76 DN80 7.5 Single channel 6

KRT E 80-250-4 255 76 DN80 11.8 Single channel 7

KRT E 80-250-4 270 76 DN80 11.8 Single channel 8

Grundfos type Curve no.

SEV.80.80.11.4 1

SEV.80.80.11.4 1

SEV.80.80.13.4 2

SEV.80.80.15.4 3

SEV.80.80.22.4 4SEV.80.80.40.4 5

Grundfos type Curve no.

SV 152 H 3

SV 212 H 4

SV 302 H 5

SEV.100.100.40.4 1

SEV.100.100.55.4 2

Grundfos type Curve no.

SE1.80.80.55.4 1

SE1.80.100.75.4 2

S1 124 BM 3

S1 124 AH 4

18 19

0 5 10 15 20 25 30 35 40 45 50 Q [l/s]

0

10

20

30

40

50

60

70

H[m]

0   40 80 120 160 Q [m³/h]

6   7

8

9

10

2

1

3

5

4

GRUNDFOS

KSB

Page 11: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 11/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 5 10 15 20 25 30 35 40 45 50 55 60 Q [l/s]

0

5

10

15

20

25

H[m]

0 40 80 120 160 200 Q [m³/h]

24

  6

1

3

5

8

10117

9

12

GRUNDFOS

KSB

 

0 4 8 12 16 20 24 28 32 Q [l/s]

0

4

8

12

16

H[m]

0 20 40 60 80 100 Q [m³/h]

7

6

8  9

  10   1112   3

4

5 SEV

SV

 

0 5 10 15 20 25 30 35 40 45 50 Q [l/s]

0

4

8

12

16

20

H[m]

0 40 80 120 160 Q [m³/h]

1

2

34

5   6   78

SEV

SV

 

KSB type Impeller Free passage Discharge P2 (kW) Imp eller typ e Curve no.

KRT E 100-250-4   202 90 DN100 4 Single channel 7

KRT E 100-250-4   220 90 DN100 5.5 Single channel 9

KRT E 100-250-4   245 90 DN100 7.5 Single channel 12

KRT K 100-250-4   210 71 DN100 4 2-channel 8

KRT K 100-250-4   220 71 DN100 5.5 2-channel 10KRT K 100-250-4   230 71 DN100 7.5 2-channel 11

Grundfos type Curve no.

SE1.100.100.40.4 1

SE1.100.100.55.4 3

SE1.100.100.75.4 5

SE1.80.100.40.4 2

SE1.80.100.55.4 4SE1.80.100.75.4 6

GrundfosS pump type

Free passage Discharge P2 (kW) Impeller type Curve no.

SV 034 C 100 100 2.9 SuperVortex 5

SV 044 C 100 100 4.2 SuperVortex 6

SV 064 B 80x100 100 5.5 SuperVortex 7

SV 074 B 80x100 100 7 SuperVortex 8

Grundfos type Curve no. Adaptor

SEV.80.80.11.4 1 96572290

SEV.80.80.13.4 2 96572290

SEV.80.80.15.4 3 96572290

SEV.80.80.22.4 4 96572290

SEV.80.80.40.4 5 96572290

SEV.80.80.40.4 5 96572290

Grundfos type Curve no. Adaptor

SEV.100 .100 .30. 4 1 96572291

SEV.100 .100 .40. 4 2 96572291

SEV.100 .100 .55. 4 3 96572291

SEV.100 .100 .7 5. 4 4 96572291

Grundfos S pumps

GrundfosS pump type

Free passage Discharge P2 (kW) Impeller type Curve no.

SV 014 BL 80 80 1,65 SuperVortex 6

SV 014 B 80 80 1.65 SuperVortex 7

SV 024 B 80 80 1.65 SuperVortex 8

SV 024 BH 80 80 2.3 SuperVortex 9

SV 034 CH 80 80 2.9 SuperVortex 10

SV 044 CH 80 80 4.2 SuperVortex 11

20 21

Page 12: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 12/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 4 8 12 16 20 24 28 32 36 Q [l/s]

0

5

10

15

20

25

30

35

40

45

H[m]

0 40 80 120 Q [m³/h]

85   6   7

4

1

23

SEV

SV

 

0 10 20 30 40 50 60 70 80 Q [l/s]

0

5

10

15

20

25

H[m]

0 40 80 120 160 200 240 280 Q [m³/h]

6

9

7

10

8

4

3

51

2

SE1

S1

 

0 10 20 30 40 50 60 70 80 90 Q [l/s]

0

5

10

15

20

25

H[m]

0 50 100 150 200 250 300 Q [m³/h]

6

78

10

9

2

5

1

3

4

SEV

SV

 

GrundfosS pump type

Free passage Discharge P2 (kW) Impeller type Curve no.

SV 042 C 80 80 4.5 SuperVortex 5

SV 072 BH 80 80 7.4 SuperVortex 6

SV 092 BH 80 80 9.4 SuperVortex 7

SV 122 BH 80 80 11.5 SuperVortex 8

GrundfosS pump type

Free passage Discharge P2 (kW) Impeller type Curve no.

S1 044 C 100 100 4.2 Single channel 6

S1 064 AM 100 100 5.5 Single channel 7

S1 074 AM 100 100 7 Single channel 8

S1 064 AH 80 100 5.5 Single channel 9S1 074 AH 80 100 7 Single channel 10

S1 074 AS 80 100 7 Single channel

GrundfosS pump type

Free passage Discharge P2 (kW) Impeller type Curve no.

S1 074 L 100 150 7 Single channel 9

S1 054 CM 100 100 5.5 Single channel 6

S1 074 CM 100 100 7.5 Single channel 8

S1 054 H 80 100 5.5 Single channel 7

S1 074 H 80 100 7.5 Single channel 10

Grundfos type Curve no. Adaptor

SEV.80.80.40.2 1 96255641

SEV.80.80.75.2 2 96255641

SEV.80.80.92.2 3 96255641

S EV.8 0. 80. 11 0. 2 4 9 62 556 41

Grundfos type Curve no. Adaptor

SE1.100 .100 .40. 4 1 96572291

SE1.100 .100 .40. 4 1 96572291

S E1. 100.1 00.5 5. 4 2 9 6572 29 1

S E1. 80.1 00. 55. 4 3 9 6572 29 1

S E1. 80.1 00. 75. 4 5 9 6572 29 1

SE1.80.80.75.4 4 96255641

Grundfos type Curve no. Adaptor

S E1. 100.1 50. 75. 4 5 9 65 72 29 6

S E1. 100.1 00.5 5. 4 1 9 6572 29 1

S E1. 100.1 00.7 5. 4 3 9 6572 29 1

S E1. 80.1 00. 55. 4 2 9 6572 29 1S E1. 80.1 00. 75. 4 4 9 6572 29 1

22 23

Page 13: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 13/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0Q [l/s]

0

5

10

15

20

25

30

35

40

45

H[m]

0 4 8 12 16   20 24 28Q [m³/h]

6 7

8

9   10

11

1

2

3

4

5   SEG

APG

 

0 1 2 3 4 5 6 7 8 9 1 0 11 Q [l/s]

0

2

4

6

8

10

12

14

16

18

20

22

H[m]

0 10 20 30 40 Q [m³/h]

45

6

7

1

23 EF

AP

 

0 2   4 6 8   10 12 14   1 6 18 20 Q [l/s]

0

2

4

6

8

10

12

14

16

18

20

22

H[m]

0 10 20 30 40 50 60 70 Q [m³/h]

7 89   10

11

12

2

3

1

4

5

6

EFAP

 

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

AP30.50.07.1 30 2” 0.7 Open single-vane 4

AP30.50.09.3 30 2” 0.9 Open single-vane 5

AP30.50.11.1 30 2” 1.1 Open single-vane 6

AP30.50.12.3 30 2” 1.2 Open single-vane 7

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

APG.50.06 - 2” 0.6 Grinder 6

APG.50.09 - 2” 0.9 Grinder 7

APG.50.14 - 2” 1.4 Grinder 8

APG.50.19 - 2” 1.9 Grinder 9

APG.50.31 - 2” 3.1 Grinder 10APG.50.48 - DN50 4.8 Grinder 11

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

AP51.65.07 50 2” 0.7 Single channel 9

AP51.65.12 50 2” 1.2 Single channel 10

AP51.65.17.3 50 2” 1.7 Single channel 11

AP51.65.22.3 (Ex) 50 2” 2.2 Single channel 12AP65.65.09.1.V 65 DN65 0.9 Vortex 7

AP65.65.12.1.V 65 DN65 1.2 Vortex 8

Grundfos type Curve no. Adaptor

SEG.40.09 1 96578891

SEG.40.09 1 96578891

SEG.40.15 2 96578891

SEG.40.26 3 96578891

SEG.40.31 4 96578891SEG.40.40 5 N/A

Grundfos type Curve no. Adaptor

EF30.50.06 1 N/A

EF30.50.09 2 N/A

EF30.50.11 3 N/A

EF30.50.11 3 N/A

Grundfos type Curve no. Adaptor

SE1.50.65.06 1 N/A

SE1.50.65.11 4 N/A

SE1.50.65.15 5 N/A

SE1.50.65.22 6 N/ASEV.65.65.11 2 N/A

SEV.65.65.15 3 N/A

N/A: NOT AVAILABLE

N/A: NOT AVAILABLE

N/A: NOT AVAILABLE

24 25

Page 14: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 14/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [l/s]

0

2

4

6

8

10

12

14

16

18

20

H[m]

0 50 100 150 200 Q [m³/h]

95

6

7   81

2

3

4 SEVAP

 

0 4 8 12 16 20 24 28 32 36 Q [l/s]

0

2

4

6

8

10

12

14

16

18

H[m]

0 20 40 60 80 100 120 Q [m³/h]

5

67 8

3   4

1   2

SEV, SE1

AP

 

0 10   2 0 3 0 4 0   5 0 6 0 7 0   80 90 100 110 120 130 140 Q [l/s]

0

10

20

30

40

50

H[m]

0 100 200 300 400 Q [m³/h]

6 7

8 9

10   11

1

2

3

4

5S1

AP

 

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

AP65.100.24.V 65 DN100 2.4 Vortex 5

AP65.100.32.V 65 DN100 3.2 Vortex 6

AP65.100.45.V 65 DN100 4.5 Vortex 7

AP65.100.61.V 65 DN100 6.1 Vortex 8

AP65.100.130.V 65 DN100 13 Vortex 9

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

AP70.80.09.3 (Ex) 70 DN80 0.9 Single channel 5

AP70.80.13.3 (Ex) 70 DN80 1.3 Single channel 6

AP70.80.19.3 (Ex) 70 DN80 1.9 Single channel 7

AP70.80.24.3 (Ex) 70 DN80 2.4 Single channel 8

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

AP80.150.250 (Ex) 80 DN150 25 2-channel 6

AP80.150.300 (Ex) 80 DN150 30 2-channel 7

AP80.150.330 (Ex) 80 DN150 33 2-channel 8

AP80.150.350 (Ex) 80 DN150 35 2-channel 9AP80.150.370 (Ex) 80 DN150 37 2-channel 10

AP80.150.450 (Ex) 80 DN150 45 2-channel 11

Grundfos type Curve no. Adaptor

S EV.1 00. 100. 30 1 9 65 72 28 1

S EV.1 00. 100. 40 2 9 65 72 28 1

SEV.100.100.55 3 96572281

S EV.1 00. 100. 75 4 9 65 72 28 1

S EV.1 00. 100. 75 4 9 65 72 28 1

Grundfos type Curve no. Adaptor

SEV.80.80.11 1 96572268

SEV.80.80.15 2 96572268

SE1.80.80.15 3 96572268

SE1.80.80.22 4 96572268

Grundfos type Curve no. Adaptor

S1 224 M 1 96572283

S1 264 M 2 96572283

S1 304 M 3 96572283

S1 404 M 4 96572283S1 504 M 5 96572283

S1 504 M 5 96572283

26 27

Page 15: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 15/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 2 4 6 8 10 1 2 1 4 16 18 2 0 22 2 4 Q [l/s]

0

2

46

8

10

12

14

16

18

H[m]

0 20 40 60 80 Q [m³/h]

6

7   8   9

101

2 3

4

5

SEV

AP

 

0 5 10 15 20 25 30 35 40 45Q [l/s]

0

10

20

30

40

50

60

70

H[m]

0 20 40 60 80 100   1 2 0 1 40 Q [ m³ /h ]

9

10

11

12

78

  6

5

4

123

SEV, SV

AP

 

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

AP80.80.10.V (Ex) 80 DN80 1 Vortex 6

AP80.80.13.V (Ex) 80 DN80 1.3 Vortex 7

AP80.80.20.V (Ex) 80 DN80 2 Vortex 8

AP80.80.26.V (Ex) 80 DN80 2.6 Vortex 9

AP80.80.48.V (Ex) 80 DN80 4.8 Vortex 10

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

AP80.80.65.V (Ex)   80 DN80 6.5 Vortex 7

AP80.80.92.V (Ex)   80 DN80 9.2 Vortex 8

AP80.80.107.V (Ex)   80 DN80 10.7 Vortex 9

AP80.80.160.V (Ex)   80 DN80 16 Vortex 10

AP80.80.190.V (Ex)   80 DN80 19 Vortex 11

AP80.80.250.V (Ex)   80 DN80 25 Vortex 12

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

AP100.100.24 (Ex)   100 DN100 2.4 Single channel 9

AP100.100.32 (Ex)   100 DN100 3.2 Single channel 10

AP100.100.45 (Ex)   100 DN100 4.5 Single channel 11

AP100.100.54 (Ex)   100 DN100 5.4 Single channel 12AP100.100.61 (Ex)   100 DN100 6.1 Single channel 13

AP100.100.80 (Ex)   100 DN100 8 Single channel 14

AP100.100.115 (Ex)   100 DN100 11.5 Single channel 15

AP100.100.130 (Ex)   100 DN100 13 Single channel 16

AP100.100.135 (Ex)   100 DN100 13.5 Single channel 17

Grundfos type Curve no. Adaptor

SEV.80.80.10 1 96572268

SEV.80.80.13 2 96572268

SEV.80.80.15 3 96572268

SEV.80.80.22 4 96572268

SEV.80.80.40 5 96572268

Grundfos type Curve no. Adaptor

SEV.80.80.60 1 96572268

SEV.80.80.75 2 96572268

SEV.80.80.92 3 96572268

SEV.80.80.110 4 96572268

SV 212 H 5 96572268

SV 302 H 6 96572268

Grundfos type Curve no. Adaptor

S1 034 DH 1 *

S E1. 100.1 00.4 0 2 9 65 72 28 1

S E1. 100.1 00.4 0 2 9 65 72 28 1

SE1.100.100.55 3 96572281SE1.80.100.55 4 96572281

S E1. 100.. 100. 75 5 9 65 72 28 1

S1 124 AH 6 96572281

S1 134 H 7 96572281

S1 174 H 8 96572281

28 29

0 5 1 0 1 5 20 25 30 35 4 0 4 5 50 55 6 0 6 5 70 75 80 Q [ l /s]

0

5

10

15

20

25

30

35

H[m]

0 40 80 120 160 200 240 Q [m³/h]

15

1617

9101112

13

14

67

8

14

2   35

SE1, S1

AP

*The existing AP guide claw can be re-used for the S1 pump.

Page 16: Ww Replacementguide Low

7/23/2019 Ww Replacementguide Low

http://slidepdf.com/reader/full/ww-replacementguide-low 16/16

PUMP COMPARISON GUIDE PUMP COMPARISON GUIDE

Pump to be replaced Grundfos recommends

0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 00 11 0 12 0 1 30 Q [ l/ s]

0

5

1015

20

25

30

35

40

45

H[m]

0 100 200 300 400 Q [m³/h]

10111213

1415

16

9

12

3

4

56

7

8

S1

AP

 

0 20 40 60 80 100 120 140 160 180 200 220 240 Q [ l/s]

0

5

10

15

20

25

30

H[m]

0 200 400 600 800 Q [m³/h]

5

67

81   3

  4

2

S1, S2

AP

 

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

AP100.150.80 (Ex)   100 DN150 8 Single channel 9

AP100.150.115 (Ex)   100 DN150 11.5 Single channel 10

AP100.150.130 (Ex)   100 DN150 13 Single channel 11

AP100.150.170 (Ex)   100 DN150 17 Single channel 12

AP100.150.220 (Ex)   100 DN150 22 Single channel 13

AP100.150.260 (Ex)   100 DN150 26 Single channel 14

AP100.150.300 (Ex)   100 DN150 30 Single channel 15

AP100.150.330 (Ex)   100 DN150 33 Single channel 16

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

AP100.200.170 (Ex)   100 DN200 17 2-channel 5

AP100.200.200 (Ex)   100 DN200 20 2-channel 6

AP100.200.220 (Ex)   100 DN200 22 2-channel 7

AP100.200.250 (Ex)   100 DN200 25 2-channel 8

Grundfos AP type Free passage Discharge P2 (kW) Impeller type Curve no.

AP130.250.170 (Ex)   130 DN250 17 2-channel 5

AP130.250.200 (Ex)   130 DN250 20 2-channel 6

AP130.250.220 (Ex)   130 DN250 22 2-channel 7

AP130.250.250 (Ex)   130 DN250 25 2-channel 8

AP130.250.300 (Ex)   130 DN250 30 2-channel 9

AP130.250.350 (Ex)   130 DN250 35 2-channel 10

Grundfos type Curve no. Adaptor

S1 074 L 1 96572283

S1 124 AL 2 96572283

S1 134 M 3 96572283

S1 174 M 4 96572283

S1 224 M 5 96572283

S1 264 M 6 96572283

S1 304 M 7 96572283

S1 404 M 8 96572283

Grundfos type Curve no. Adaptor

S1 134 BL 1 96581421

S1 174 BL 2 96581421

S2 224 AL 3 96581421

S2 264 AL 4 96581421

Grundfos type Curve no. Adaptor

S2 156 E 1 96581423

S2 156 E 1 96581423

S2 226 E 3 96581423

S2 226 E 3 96581423

S2 304 E 2 96581423

S2 404 E 4 96581423

0 40 80 120 160 200 240 280 320 Q [l/s]

0

2

4

6

810

12

14

16

18

20

H[m]

0 200 400 600 800 1000 1200 Q [m³/h]

5

6 7

89

1   2 3

4  S2

AP

 

30 31