7/30/2019 WT calcs enhance pro.xls http://slidepdf.com/reader/full/wt-calcs-enhance-proxls 1/3 WALL THICKNESS CALCULA Version 1.0 (DSS pipes as per API 5LC) Validation date Project Name Project Number 80166 Design Pressure (P) 120 bar g psi g Design Factor (F) off plot on plot per SP-1211 SMYS (psi) 69618 psi 480 Mpa at 20 Deg C as per SP-1189 Joint Factor (E) 1 Corrosion Allowance mm as material is DSS Temperature derating 0.871 factor (T) Design code Design Seamless Factor (F) (S) OR Calculated Calculated inch Welded (W inch mm 1 6.625 0.72 0.132 3.355 2 6.625 0.6 0.158 4.026 3 8.625 0.72 0.172 4.368 4 8.625 0.6 0.206 5.241 5 10.75 0.72 0.214 5.444 6 10.75 0.6 0.257 6.532 7 12.75 0.72 0.254 6.456 8 12.75 0.6 0.305 7.748 9 22 0.72 W  0.439 11.140 10 22 0.6 W  0.526 13.368 Sl No 1740.45 Selected Wall thickness calcs results DSS Kauther Field Gathering System (with enhance property, 418 Mpa @ 130 0.4, 0.5 or 0.6 0.4, 0.5, 0.6 or 0.72 Outside Dia. (D) t mm 5.7 3.6 7.8 13.4 11.4 6.6 6.6 4.1 4.6 5.3 146731507.xls.ms_office\WTcalcs 1 of 3

Upload: vijeesh-mg

Post on 14-Apr-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WT calcs enhance pro.xls

7/30/2019 WT calcs enhance pro.xls

http://slidepdf.com/reader/full/wt-calcs-enhance-proxls 1/3

WALL THICKNESS CALCULA

Version 1.0  (DSS pipes as per API 5LC)

Validation date

Project Name

Project Number  80166 

Design Pressure (P) 120 bar g psi g

Design Factor (F) off plot

on plot per SP-1211

SMYS (psi) 69618 psi 480 Mpa at 20 Deg C as per SP-1189

Joint Factor (E) 1

Corrosion Allowance 0  mm as material is DSS

Temperature derating 0.871

factor (T)

Design code

Design Seamless

Factor (F) (S) OR Calculated Calculated

inch Welded (W inch mm

1 6.625 0.72 W   0.132 3.355

2 6.625 0.6 W   0.158 4.026

3 8.625 0.72 W   0.172 4.3684 8.625 0.6 W   0.206 5.241

5 10.75 0.72 W   0.214 5.444

6 10.75 0.6 W   0.257 6.532

7 12.75 0.72 W   0.254 6.456

8 12.75 0.6 W   0.305 7.748

9 22 0.72 W   0.439 11.140

10 22 0.6 W   0.526 13.368

Sl No

1740.45

Selected

Wall thickness calcs resultsDSS

Kauther Field Gathering System (with enhance property, 418 Mpa @ 130

0.4, 0.5 or 0.6

0.4, 0.5, 0.6 or 0.72

Outside

Dia. (D)

t

mm

5.7 

3.6

7.8 

13.4

11.4

6.6 

6.6 

4.1

4.6

5.3

146731507.xls.ms_office\WTcalcs 1 of 3

Page 2: WT calcs enhance pro.xls

7/30/2019 WT calcs enhance pro.xls

http://slidepdf.com/reader/full/wt-calcs-enhance-proxls 2/3

Page 3: WT calcs enhance pro.xls

7/30/2019 WT calcs enhance pro.xls

http://slidepdf.com/reader/full/wt-calcs-enhance-proxls 3/3

TONNAGE CALCULATIONSVersion 1.0 

Validation date

Project Name Kauther Field Gathering System (with enhance property, 418 Mpa @ 130 deg C)

Project Number  80166

Design Pressure (P) 120 bar g 1740.45 psi g

Design Factor off plot

on plot per SP-1211

SMYS (N/mm2) 65000 psi 450 Mpa upto 110 Deg C as per SP-1189

 

Sl No Design DSS

Factor Length (m) wall thickness tonnage

inch mm tons

1 6.625 0.72 7136  3.600 104.33

2 6.625 0.6 592 4.100 9.83

3 8.625 0.72 31272 4.600 760.87

4 8.625 0.6 2046  5.300 57.17

5 10.75 0.72 7550 5.700 283.74

6 10.75 0.6 776  6.600 33.65

7 12.75 0.72 3617  6.600 186.77

8 12.75 0.6 94 7.800 5.71

9 22 0.72 5406  11.400 831.97

10 22 0.6 106  13.400 19.10

Total 58595 2293.15