Accessories Catalog Cartridge Valves 43 WSM 2-Way Solenoid Cartridge Valves Features Long life and low noise level due to oil-immersed solenoid armature. Electro-magnetic actuation in all standard international DC and AC voltages and many electrical connection types available. Minimal wear and long life due to hardened and polished control elements. In the closed position the flow paths are shut off by means of a cone seat. Solenoid coils can be rotated through 360˚ and replaced without opening the hydraulic system. Surfaces are zinc-plated. Built-in seals protect solenoid coils from water penetration. Compact construction enables space-saving installation in connection hous- ings and control blocks. Specifications Operating Pressure: max. 350 bar (see page 45,46 for limits) Flow rate: max. 40 l/min (see page 45,46 for limits) Internal leakage: leak free Fluid Temperature range: -20° to 120°C Ambient temperature range: -20° to 60°C Type of voltage: DC solenoid, AC voltage is rectified using a bridge rectifier built into the coil Nominal voltage (at 20˚C): 1.5 A at 12 V DC 0.8 A at 24 V DC Voltage tolerance: -15% to 15% Switch-on time: 100% (continuous) Switching time: see pages 45, 46 Operating fluid: hydraulic oil to DIN 51524 Part 1 and 2 Viscosity range: 10 mm2/s to 420 mm2/s is recommended Filtration: max. permissible contaminiation level of the operating fluid to ISO 4406 Class 21/19/16 Mounting position: optional Materials: valve body: high tensile steel closing elements: hardened and polished steel seals: NBR (standard) FKM (optional) back-up ring in PTFE Cavity: 06020 Weight: Valve complete: 0.33 kg Coil only: 0.19 kg

Upload: andrei-vlad

Post on 11-Sep-2015

9 views

Category:

Documents


2 download

DESCRIPTION

ngfxvcvndn

TRANSCRIPT

  • Accessories Catalog

    Cartridge Valves

    43

    WSM 2-Way Solenoid Cartridge Valves

    Features Long life and low noise level due to oil-immersed solenoid armature.

    Electro-magnetic actuation in all standard international DC and AC voltagesand many electrical connection types available.

    Minimal wear and long life due to hardened and polished control elements.

    In the closed position the flow paths are shut off by means of a cone seat.

    Solenoid coils can be rotated through 360 and replaced without opening thehydraulic system.

    Surfaces are zinc-plated.

    Built-in seals protect solenoid coils from water penetration.

    Compact construction enables space-saving installation in connection hous-ings and control blocks.

    SpecificationsOperating Pressure: max. 350 bar (see page 45,46 for limits)Flow rate: max. 40 l/min (see page 45,46 for limits)Internal leakage: leak freeFluid Temperature range: -20 to 120CAmbient temperature range: -20 to 60CType of voltage: DC solenoid, AC voltage is rectified using a

    bridge rectifier built into the coilNominal voltage (at 20C): 1.5 A at 12 V DC

    0.8 A at 24 V DCVoltage tolerance: -15% to 15%Switch-on time: 100% (continuous)Switching time: see pages 45, 46Operating fluid: hydraulic oil to DIN 51524 Part 1 and 2Viscosity range: 10 mm2/s to 420 mm2/s is recommendedFiltration: max. permissible contaminiation level of the

    operating fluidto ISO 4406 Class 21/19/16

    Mounting position: optionalMaterials: valve body: high tensile steel

    closing elements: hardened and polished steel

    seals: NBR (standard)FKM (optional)back-up ring in PTFE

    Cavity: 06020Weight: Valve complete: 0.33 kg

    Coil only: 0.19 kg

  • Accessories Catalog

    Cartridge Valves

    441-877-GO HYDAC

    Model Code WSM 06020 Y-01 _ -C-N-24DG Z4.Series

    Directional 2-Way Solenoid Cartridge Valve

    Cavity Designation

    Function CodeY, Z, YR, ZR, W, V

    Modification Number(Latest Version Always Supplied)

    Manual OverrideOmit = No manual overrideM = Maual overide

    ConfigurationC = Cartridge OnlySS6 = Steel inline block, Zinc Plated, SAE-6 Ports

    Seal MaterialN = NBRV = FPM (Special Order Only)

    Coil Rating (Male DIN 43650)12DG = 12V DC24DG = 24V DC115AG = 115V AC230AG = 230V AC

    DIN 43560 Electrical ConnectorOmit = Standard EN 175301-803 (Male DIN 43650) Z4 Plug not includedZ4 = With plug (Female DIN 43650) Special Order Only

    DIMENSIONS

    Model Codes containing selections listed in red italics are non-standard items Minimum quantities may apply Contact HYDAC for information and availabilityNot all combinations are available

    *Subject to technical modifications.All measurements in millimeters.

    Note:For Y, YR, W and V:Manual override is standardpush button.

    For Z and ZR: Remove coil nut and turnknob counterclockwise formanual override.

    CAVITY

  • Accessories Catalog45

    2

    1

    Up to 40 l/minUp to 350 bar

    When the solenoid coil is not energized the valve is closed from port 2 to port 1. Inthe reverse direction there is free flow through the valve. The valve spool opens at adifferential pressure of approx. 1.5 bar (check function). When the solenoid coil isenergized, there is free flow through the valve from port 2 to port 1. Flow from port 1to port 2 is severly restricted in this mode.

    po rd eru sserP

    Flow rate

    Measured at 34 cStTOil = 46 C

    2 1 energized

    1 2 non-energized

    0 5 10 15 20 25 30 35 40 l/min

    bar8

    6

    4

    2

    0

    Cartridge Valves

    WSM06020Z-01

    WSM06020Y-01When the solenoid coil is not energized there is free flow through the valve from port2 to port 1. Flow from port 1 to port 2 is severly restricted in this mode. When thesolenoid coil is energized the valve is closed from port 2 to port 1. In the reversedirection there is free flow through the valve when the pressure force on the spoolexceeds the solenoid force (approx. 9 to 20 bar).

    2

    1

    Up to 40 l/minUp to 350 bar

    po rd erusserP

    Flow rate

    Measured at 34 cStToil = 46 C

    0 5 10 15 20 25 30 35 40 l/min

    bar8

    6

    4

    2

    0

    2 1 non-energized

    NOTE: The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions notdescribed, please contact the relevant technical department. Subject to technical modifications.

    PRESSURE DROP

    Normally closedSwitch TimeOn: approx 35msOff: approx 50ms

    Switch TimeOn: approx 50msOff: approx 35ms

    Normally open

    WSM 2-Way Solenoid Cartridge Valves

    PRESSURE DROP

  • Accessories Catalog 461-877-GO HYDAC

    Cartridge Valves

    WSM06020YR-01

    WSM06020ZR-01

    WSM06020W-01 WSM06020V-01

    2

    1

    po rd erusser

    P

    Flow rate

    Measured at 34 cStToil = 46 C

    2 1 non-energized

    0 5 10 15 20 25 30 35 40 l/min

    bar8

    6

    4

    2

    0

    1 2 non-energized

    2

    1

    po rd eru sserP

    Flow rate

    Measured at 34 cStTOil = 46 C

    2 1 energized

    1 2 non-energized

    0 5 10 15 20 25 30 35 40 l/min

    bar8

    6

    4

    2

    01 2 energized

    When the solenoid coil is not energized there is free flowthrough the valve in both directions. When the solenoidcoil is energized the valve is closed from port 2 to port1.In the reverse direction there is free flow through thevalve when the pressure force on the spool exceeds thesolenoid force (approx. 9 to 20 bar).

    When the solenoid coil is not energized the valve isclosed from port 2 to port 1. In the reverse direction thereis free flow through the valve. The valve spool opens at adifferential pressure of approx. 1.5 bar (check function).When the solenoid coil is energized there is free flowthrough the valve in both directions.

    Up to 19 l/minUp to 250 bar

    When the solenoid coil is not energized the valve is closedin both directions. When the solenoid coil is energizedthere is free flow through the valve in both directions.

    2

    1

    2

    1

    PRESSURE DROP

    PRESSURE DROP

    Up to 20 l/minUp to 350 bar

    When the solenoid coil is not energized there is free flowthrough the valve in both directions. When the solenoidcoil is energized the valve is closed in both directions.

    Switch TimeOn: approx 50msOff: approx 35ms

    Switch TimeOn: approx 35msOff: approx 50ms

    Normally open, with reverse flow

    Normally closed, with reverse flow

    Switch TimeOn: approx 40msOff: approx 60ms

    Normally closed,Bi-directional

    Switch TimeOn: approx 35msOff: approx 50ms

    Normally closed,Bi-directional

    Up to 40 l/minUp to 350 bar

    Up to 40 l/minUp to 350 bar

  • Accessories Catalog

    Cartridge Valves

    47

    SpecificationsMaximum Operating Pressure

    7,000 psi (500 bar)P1 P2 P3

    Nominal Flow3 gpm (12 l/min)(flow only in direction of arrows shown)

    Fluid Temperature Range-4F to 176F (-20C to 80C)

    Ambient Temperature Range-4F to 104F (-20C to 40C)

    Recommended MediaGeneral Purpose Hydraulic Fluid

    Viscosity Range59 SUS to 1,760 SUS

    Filtration Required20 Micron Absolute Rating

    Internal LeakageLeakfree

    Duty CycleContinuous at 110% Rated Voltage

    Solenoid Current (nominal)24 VDC, 1.04 Amps110 VAC, 0.26 Amps

    Solenoid Coil Power (nominal)26 Watts

    Voltage Tolerance+10%, -5%

    MaterialsValve Body:High Strength Carbon Steel

    Valve Poppet:Hardened and Polished Alloy Steel

    Line Body:Carbon Steel

    WSE3 3-Way Solenoid Cartridge Valves

    WSE 3 E 0 C . X / G12 - Z4 - 1/4 NPT

    Directional Control ValveWSE

    Size

    Maximum Flow3 = 3 gpm (12 l/min)

    Type of ConnectionE = Cartridge Valve OnlyR = Valve with Line Body

    Type

    ConfigurationC = Normally Closed Port 1-2D = Normally Open Port 1-2

    Modification Number (latest version always supplied)

    SolenoidG12 = 12 VDCG24 = 24 VDC (standard)W110 = 110 VAC (standard)W230 = 230 VAC

    Electrical ConnectionsZ4 = DIN 43650 Connector (standard)

    Line Body(omit) = None (if E was chosen in Type of Connection above)

    1/4 NPT = 1/4 NPT (if R was chosen in Type of Connection above)SAE-4 = SAE 4Model Codes containing selections listed in red italics are non-standard items Minimum quantities may apply

    Contact HYDAC for information and availabilityNot all combinations are available

    Model Code

    Hydraulic Symbols

    Features Leakfree poppet design

    No dynamic seals

    Excellent heat dissipation

    Low operating noise level

    Fully encapsulated coil

    DIN 43650 connector standard

    Fluoroelastomer seals standard

    Normally Open 1-2(Configuration D)

    Normally Closed 1-2(Configuration C)

    Connections1 = Pressure Line2 = Actuator3 = Tank Line1

    2

    3 1

    2

    3

  • Accessories Catalog

    Cartridge Valves

    481-877-GO HYDAC

    Dimensions: 3-Way Solenoid Poppet ValveRef: Install in HYDAC Cavity 03230

    2.36"(60 mm)

    2.36"(60 mm)

    1.18"(30 mm)

    3

    1

    2

    1.42"(36 mm)

    0.47"(12 mm)

    0.59"(15 mm)

    0.59"(15

    1

    3

    2

    mm)

    1.24"(31.5 mm)

    0.59"(15 mm)

    2 Mounting Holes 0.34"

    (8.5 mm)

    Port 1/4" NPTor SAE-4(3 places)

    1.18"(30 mm)

    CavityCenterline 1.18"(30 mm)

    1.00"(25.4 mm)

    0.394"(10 mm)

    0.354"(9 mm)

    0.118"(3 mm)1.52"(38.5 mm)

    3.03"

    After loosening nutcoil can be rotatedthrough 360

    (77 mm)4.55"(115.5 mm)

    1.42"(36 mm) 3.15"(80 mm) PG11

    connector socket4 x 90 displacable

    M20 x 1.5

    0.93"(23.5 mm)Hex 0.94"(24 mm)Torque18-22 ft-lbs25-30 Nm

    10

    0

    20

    30

    40

    1086420 12

    a

    b

    50

    Q - Flow (l/min)

    P

    ress

    ure

    (bar

    )

    p/Q curvesMeasured at v = 34 mm2/sWSE 3 E

    Dimensions: Line Body Pressure Drop vs. Flow

    Block with 1/4 NPT Ports: 02056010Block with SAE-4 Ports: 02056012(Blocks are not normally stocked items)

    Configuration Flow Direction CurveC energized 1 to 2 a de-energized 2 to 3 aD de-energized 1 to 2 b energized 2 to 3 b

    Dimensions are for general information only, all critical dimensions should be verified by requesting a certified print.Dimensions are in inches/(mm) and lbs./(kg.)

  • Accessories Catalog

    Cartridge Valves

    49

    Specifications Operating Pressure Range

    Inlet (Port 1): to 9,000 psi (630 bar)Outlet (Port 2): to 5,000 psi (350bar)

    Nominal Flow8 gpm (30 l/min)

    Operating Temperature Range-4F to +176F (-20C to +80C)

    Recommended MediaGeneral Purpose Hydraulic Fluid

    Viscosity Range35 SUS to 3700 SUS

    Filtration Rating20 Micron Absolute

    MaterialsValve Body:High Strength Carbon Steel

    Valve Poppet:Hardened and Polished Alloy Steel

    Line Body:Carbon Steel

    DB4 Series Pressure Relief Valves

    DB4 E - 01 X - 100 V .

    Pressure Relief ValveDB4

    Type of ConnectionE = Relief Valve cartridge onlyR = Relief Valve with line body

    Type Number01 = (standard)

    Modification Number (latest version always supplied)

    Pressure Range100 = up to 1500 psi (100 bar)200 = up to 3000 psi (200 bar)350 = up to 5000 psi (350 bar)630 = up to 9000 psi (630 bar)

    Type of AdjustmentsV = Adjustable with tool (standard)S = Scaled Knob, Adjustable by HandF = Set by Factory (supply set pressure in bar)

    Line Body Port Size(omit) = None (if E was chosen in Type of Connection above)

    3/8NPT = 3/8 NPTSAE-6 = SAE 6

    (if R was chosen in Type of Connection above)

    Model Codes containing selections listed in red italics are non-standard items Minimum quantities may applyContact HYDAC for information and availability

    Not all combinations are available

    Model Code

    Hydraulic Symbols

    Features Direct acting Poppet design

    Low noise level

    Fast response

    Low Hysteresis

    Long service life

    Fluoroelastomer seal standard

    1 (INLET)

    2 (OUTLET)

  • Accessories Catalog

    Cartridge Valves

    501-877-GO HYDAC

    Dimensions:Valve Line Body Relief Valve

    1.575"(40 mm)

    0.197"(5 mm)

    1.26"(32 mm)

    1.26"(32 mm)

    0.594"(15.1 mm)

    1.188(30.2 mm)

    1.25"(31.8 mm)

    2.00(51 mm)

    1

    1

    2

    2

    0.594"(15.1 mm)

    cavitycenterline

    Port 3/8" NPTor SAE-6(2 Places)

    0.59"(15 mm)

    2 Mounting Holes 0.25"

    (6.35 mm)

    0.94"(24 mm)

    2.36"(60 mm)

    0.12"(3 mm)

    0.59"(15 mm)

    M20 x 1.5

    0.93"(23.5 mm)

    1.12"(28.5 mm)

    0.83"(21 mm)Width

    between flats

    Torque18-22 ft-lbs25-30 Nm

    2 (outlet)

    1 (inlet)

    0.51"(13 mm)

    Hex

    0.16"(4 mm)

    Hex Socket

    appli

    catio

    nlim

    it

    00

    300600900

    120015001800

    020406080

    100120

    Inle

    t Pre

    ssur

    e (ps

    i)

    Inle

    t Pre

    ssur

    e (ba

    r)

    Q - Flow (gpm)

    Q - Flow (l/min)

    1 2 3 4 5 6 7 8

    0 5 10 15 20 25 30

    00

    350030002500200015001000

    5000

    4080

    120160200240

    Inle

    t Pre

    ssur

    e (ps

    i)

    Inle

    t Pre

    ssur

    e (ba

    r)

    Q - Flow (gpm)

    Q - Flow (l/min)

    1 2 3 4 5 6 7 8

    0 5 10 15 20 25 30

    00

    750

    22501500

    30003750450052506000

    0

    100

    200

    300

    400

    Inle

    t Pre

    ssur

    e (ps

    i)

    Inle

    t Pre

    ssur

    e (ba

    r)

    Q - Flow (gpm)

    Q - Flow (l/min)

    1 2 3 4 5 6 7 8

    0 5 10 15 20 25 30

    00

    10500900075006000450030001500

    0100200300400500600700

    Inle

    t Pre

    ssur

    e (ps

    i)

    Inle

    t Pre

    ssur

    e (ba

    r)

    Q - Flow (gpm)

    Q - Flow (l/min)

    1 2 3 4 5 6 7 8

    0 5 10 15 20 25 30

    Size 100Pressure Range: 0-1500 psi (0-100 bar)

    Size 200Pressure Range: 0-3000 psi (0-200 bar)

    Size 350Pressure Range: 0-5000 psi (0-350 bar)

    Size 630Pressure Range: 0-9000 psi (0-630 bar)

    Adjustment Curves for Nominal Flow RatesViscosity = 170 SUS @ 120F

    Dimensions are for general information only, all critical dimensions should be verified by requesting a certified print.Dimensions are in inches/(mm) and lbs./(kg.)

    Block with 3/8 NPT Ports: 02056007Block with SAE-6 Ports: 02056008