wp4086 condition monitoring system condition · pdf filewp4086 condition monitoring system....
TRANSCRIPT
condition monitoringWP4086 Condition Monitoring System
MT_WP4086_DataSheet_R4_0
© 2012 Mita-Teknik. All rights reserved
The WP4086 CMS System surveys vibrations •with up to 8 external accelerometers
Real-time sample, calculation and storage •of vibration signals, including wind turbine operation parameters
Calculation of time domain characteristics:• - Broad band characteristics - Vibrovelocity calculation
Calculation of frequency domain characteristics:• - FFT Amplitude Spectra - FFT Envelope Spectra - Frequency selective chartacteristics
Automatic storage of daily data set and raw data•
Kinematic frequencies configuration•
Individual measurement task scheduler for •specific wind turbine
Fault features detection from time domain •and frequency domain characteristics when exceeding pre-defined threshold limits
Advanced warning and alarm handling•
The WP4086 Condition Monitoring SystemThe WP4086 Condition Monitoring System is used for vibration analysis. It surveys predetermined critical vibration levels. The frequency range is 0.1-5000 Hz and the vibration range 0.01-5.000 g. When using 786A ICP accelerometer, the ranges are up to 10,000 Hz and 15 g.
The module is used for permanent surveillance of low and high frequency vibrations in wind turbines and other applications.
The measurement of vibrations is performed by means of up to 8 external accelerometers. The real-time measurement of vibrations is controlled by a flexible measurement task scheduler, which can be individually configured with time and fre-quency domain calculations.
If the WP4086 is connected via communication to a Mita-Teknik controller it is possible to receive wind turbine real-time data which is stored with the vibration characteristics. The WP4086 provides permanent surveillance using an internal alarm or warning level. The alarm and warning level as well as the delay time can be set by the user.
The alarm is intended to operate a remote warning system through the communication channel. The alarm can also be used to shut down the wind turbine.
The alarm and warning circuit have two additional potential free relay outputs for communication with other related controller systems.
The Mita-Teknik SCADA system Gateway is used for configurations, bearing and gear database, and analysis of vibration characteristics. Includ-ing generation of reports generation of diagnostic reports.
The PC is used during installation and periodic maintenance. It is possible to perform new con-figuration of threshold levels and kinematic fre-quencies.
Accelerometer Measuring Points
WP4086 Condition Monitor
condition monitoringWP4086 Condition Monitoring System
MT_WP4086_DataSheet_R4_0
© 2012 Mita-Teknik. All rights reserved
Technical Data
Build-up
Supply VoltageNominal 24 VDCAllowed range 21.6 to 26.4 VDC
Typical 220 mAMaximum 300 mA
Power ConsumptionTypical 5.3 WMaximum 8.0 W
No. of points 8Resolution 12 bitSample rate 24000 bit/s
WP4086 ICP acc.0.3 g 0.3 g 0.9 g1.0 g 1.0 g 3.0 g5.0 g 5.0 g 15.0 g
Automatic range shift x1,x2,x4,x5,x8,x10,x16,x32Resolution 0.001 g
WP4086 ICP acc.Minimum 0.010 g 0.010 gMaximum 5.000 g 15.000 g
Time domain characteristics Broad band characteristicsVibrovelocity calculation
Frequency domain characteristics FFT Amplitude SpectraFFT Envelope SpectraFrequency selective chartacteristics
Range 0.1 Hz -10.0 Hz 0,011 Hz Range 2.0 Hz -100.0 Hz 0,028 Hz Range 20.0 Hz -1000.0 Hz 0,289 HzRange 200.0 Hz - 5000.0 Hz 1,445 HzRange 200.0 Hz -10000.0 Hz 1,445 Hz
Range 0.1 Hz -10.0 Hz 86,5 secRange 2.0 Hz -100.0 Hz 34,6 secRange 20.0 Hz -1000.0 Hz 3,46 secRange 200.0 Hz - 5000.0 Hz 0,69 secRange 200.0 Hz -10000.0 Hz 0,69 sec
Alarm DelayMinimum 0.0 sec.Maximum 25.5 sec.
No. of points 2Isolation RelayRated current per point 1 ADCRated voltage per point 42 VDCMinimum load 1.0 uW
No. of ports 1Communication interfaces M-NET optical M-NET Optical
Communication speed 300 - 38400 BAUDMax. cable length 1 KmRecommended cable type 1 x 2 x 0.25 w/shieldTermination Built-in
Operation temperature -20 to 60°CTransportation/storage temperature -40 to 85 °CMax. relative humidity 95% no condensationMax. operation height 2000 m. above sea level (higher levels only by
special agreement with Mita-Teknik)
Dimensions (WxHxD) 70 x 150 x 295 mmWeight 0.900 Kg
Degree of protection IP30Standards EN6100-6-4 (CE)
EN61000-6-2 (CE)EN61000-4-5 (Surge)
Permissible Ambient Conditions
Construction
Degree of Protection
Current Consumption
Automatic Gain Adjustment Full Scale Vibration Range Before Antialiasing filter (Automatic Range Shift)
Analog Input
Amplifier after Antialiasing filter
Alarm Level (Acceleration)
Digital Output
Ports for Optional Serial Communication
Sample Time
FFT Analysis
Signal Analysis
Port for RS485 Communication
WP4086 Condition MonitorSerial CommunicationRS485
Sensor OKRelay
No AlarmRelay
OPTIONAnalog Output
CPU
FILTER
1...FILTER
20
Accelerometer
1....
Accelerometer
8
DSP
condition monitoringWP4086 Condition Monitoring System
MT_WP4086_DataSheet_R4_0
© 2012 Mita-Teknik. All rights reserved
Technical Data
Supply VoltageNominal 24 VDCAllowed range 21.6 to 26.4 VDC
Typical 220 mAMaximum 300 mA
Power ConsumptionTypical 5.3 WMaximum 8.0 W
No. of points 8Resolution 12 bitSample rate 24000 bit/s
WP4086 ICP acc.0.3 g 0.3 g 0.9 g1.0 g 1.0 g 3.0 g5.0 g 5.0 g 15.0 g
Automatic range shift x1,x2,x4,x5,x8,x10,x16,x32Resolution 0.001 g
WP4086 ICP acc.Minimum 0.010 g 0.010 gMaximum 5.000 g 15.000 g
Time domain characteristics Broad band characteristicsVibrovelocity calculation
Frequency domain characteristics FFT Amplitude SpectraFFT Envelope SpectraFrequency selective chartacteristics
Range 0.1 Hz -10.0 Hz 0,011 Hz Range 2.0 Hz -100.0 Hz 0,028 Hz Range 20.0 Hz -1000.0 Hz 0,289 HzRange 200.0 Hz - 5000.0 Hz 1,445 HzRange 200.0 Hz -10000.0 Hz 1,445 Hz
Range 0.1 Hz -10.0 Hz 86,5 secRange 2.0 Hz -100.0 Hz 34,6 secRange 20.0 Hz -1000.0 Hz 3,46 secRange 200.0 Hz - 5000.0 Hz 0,69 secRange 200.0 Hz -10000.0 Hz 0,69 sec
Alarm DelayMinimum 0.0 sec.Maximum 25.5 sec.
No. of points 2Isolation RelayRated current per point 1 ADCRated voltage per point 42 VDCMinimum load 1.0 uW
No. of ports 1Communication interfaces M-NET optical M-NET Optical
Communication speed 300 - 38400 BAUDMax. cable length 1 KmRecommended cable type 1 x 2 x 0.25 w/shieldTermination Built-in
Operation temperature -20 to 60°CTransportation/storage temperature -40 to 85 °CMax. relative humidity 95% no condensationMax. operation height 2000 m. above sea level (higher levels only by
special agreement with Mita-Teknik)
Dimensions (WxHxD) 70 x 150 x 295 mmWeight 0.900 Kg
Degree of protection IP30Standards EN6100-6-4 (CE)
EN61000-6-2 (CE)EN61000-4-5 (Surge)
Permissible Ambient Conditions
Construction
Degree of Protection
Current Consumption
Automatic Gain Adjustment Full Scale Vibration Range Before Antialiasing filter (Automatic Range Shift)
Analog Input
Amplifier after Antialiasing filter
Alarm Level (Acceleration)
Digital Output
Ports for Optional Serial Communication
Sample Time
FFT Analysis
Signal Analysis
Port for RS485 Communication
condition monitoringWP4086 Condition Monitoring System
MT_WP4086_DataSheet_R4_0
© 2012 Mita-Teknik. All rights reserved
Mita-Teknik Ordering Information
Supply VoltageNominal 24 VDCAllowed range 21.6 to 26.4 VDC
Typical 220 mAMaximum 300 mA
Power ConsumptionTypical 5.3 WMaximum 8.0 W
No. of points 8Resolution 12 bitSample rate 24000 bit/s
WP4086 ICP acc.0.3 g 0.3 g 0.9 g1.0 g 1.0 g 3.0 g5.0 g 5.0 g 15.0 g
Automatic range shift x1,x2,x4,x5,x8,x10,x16,x32Resolution 0.001 g
WP4086 ICP acc.Minimum 0.010 g 0.010 gMaximum 5.000 g 15.000 g
Time domain characteristics Broad band characteristicsVibrovelocity calculation
Frequency domain characteristics FFT Amplitude SpectraFFT Envelope SpectraFrequency selective chartacteristics
Range 0.1 Hz -10.0 Hz 0,011 Hz Range 2.0 Hz -100.0 Hz 0,028 Hz Range 20.0 Hz -1000.0 Hz 0,289 HzRange 200.0 Hz - 5000.0 Hz 1,445 HzRange 200.0 Hz -10000.0 Hz 1,445 Hz
Range 0.1 Hz -10.0 Hz 86,5 secRange 2.0 Hz -100.0 Hz 34,6 secRange 20.0 Hz -1000.0 Hz 3,46 secRange 200.0 Hz - 5000.0 Hz 0,69 secRange 200.0 Hz -10000.0 Hz 0,69 sec
Alarm DelayMinimum 0.0 sec.Maximum 25.5 sec.
No. of points 2Isolation RelayRated current per point 1 ADCRated voltage per point 42 VDCMinimum load 1.0 uW
No. of ports 1Communication interfaces M-NET optical M-NET Optical
Communication speed 300 - 38400 BAUDMax. cable length 1 KmRecommended cable type 1 x 2 x 0.25 w/shieldTermination Built-in
Operation temperature -20 to 60°CTransportation/storage temperature -40 to 85 °CMax. relative humidity 95% no condensationMax. operation height 2000 m. above sea level (higher levels only by
special agreement with Mita-Teknik)
Dimensions (WxHxD) 70 x 150 x 295 mmWeight 0.900 Kg
Degree of protection IP30Standards EN6100-6-4 (CE)
EN61000-6-2 (CE)EN61000-4-5 (Surge)
Permissible Ambient Conditions
Construction
Degree of Protection
Current Consumption
Automatic Gain Adjustment Full Scale Vibration Range Before Antialiasing filter (Automatic Range Shift)
Analog Input
Amplifier after Antialiasing filter
Alarm Level (Acceleration)
Digital Output
Ports for Optional Serial Communication
Sample Time
FFT Analysis
Signal Analysis
Port for RS485 Communication
Technical Data
Order Number Order Name972408608 WP4086 Condition Monitor 8 channels 972408638 WP4086 Condition Monitor 8 channels, 62.5µ SP972408658 WP4086 Condition Monitor 8 channels, RS232972408636 WP4086 Condition Monitor 8 channels, 2 ICP, 62.5µ SP972408656 WP4086 Condition Monitor 8 channels, 2 ICP, RS232
Accessories972408810 WP4088 Accelerometer, 5g, 10 m. PVC Cable
972408810 consists of: 972408801 WP4088 Accellerometer, 5 g, 0.5 m.Cable, PVC97240881095 WP4088 Cable, 9.5 m., PVC 972408850 WP4088 Accelerometer, 5 g, 10 m.Cable, Halogen free
972408850 consists of:972408802 WP4088 Accelerometer, 5 g, 0.5 m. Cable, Halogen free97240885095 WP4088 Cable, 9.5 m. Halogen free9724600 ICP accelerometer with cable, isolating stud
condition monitoringWP4084 Vibration Analyser
MT_WP4084_DataSheet_R2_0
© 2012 Mita-Teknik. All rights reserved
WP4084 vibration analyser for condition •monitoring
Surveys vibrations in up to 2 directions•
Self-test circuit for vibration sensor check•
RS485 communication•
Setting of all parameters by using a supplied •PC program or via the WP controller by communication
The WP4084 Vibration AnalyserThe WP4084 Vibration Analyser is used for survey-ing vibrations in up to 2 directions. It surveys that critical vibration levels are not exceeded. The fre-quency range is of 0.1-5.0 Hz and vibration range 0.01 g to 0.300 g.
Used for permanent surveillance of low frequency vibrations in wind turbines and other applications. The measurement of vibrations is done by means of one or two accelerometers mounted in the WP4084.
Build-upWith two accelerometers it is possible to measure vibrations in x and y direction. With one accelero-meter in the x direction, one or two frequencies can be monitored. The WP4084 provides perma-nent surveillance using an internal alarm level. The alarm level and the delay time can be set by the user.
The measurement of vibrations is done by means in the vibration level. The alarm circuit has potential free relay outputs.
The alarm is intended to operate a remote warn-ing system and can also be used to shutdown the monitored process. The internal watchdog surveys the power supply, cable ruptures and accelerometer test function.
The accelerometer self test is automatically ex-ecuted every hour. The PC is used for parameter setup by means of a PC program supplied by us. The PC is useful during installation and periodic maintenance if there is no permanent communica-tion to a main controller. The PC program makes it possible to adjust: Center frequency Fo, bandwidth BW, alarm level, delay time and relay function.
If the WP4084 is connected via communication to one of our controllers the adjustment will be done via the controller. Hereby, it is possible to define a lower warning level for preparing the next maintanceof the monitored process.
condition monitoringWP4084 Vibration Analyser
MT_WP4084_DataSheet_R2_0
© 2012 Mita-Teknik. All rights reserved
Technical Data
Build-up
WP4084 Vibration AnalyserSerial CommunicationRS485 or CANBUS
Sensor OKRelay
No AlarmRealy
CPU
FILTER
1...FILTER
2
Accelerometer
1....
Accelerometer
2OPTIONAnalog Output
Supply VoltageNominal 24 VDCAllowed range 21.6 to 26.4 VDC
Typical 80 mAMaximum 250 mA
Power ConsumptionTypical 1.9 WMaximum 6.6 W
Alarm level (acceleration) Minimum 0.100 m/s2 Maximum 3.000 m/s2 Minimum 0.010 g Maximum 0.300 gResolution 0.001Accuracy @ 25°C, typical <0.003 g
Frequency Range Minimum 0.10 Ηz Maximum 5.00 ΗzResolution 0.01 Hz
Minimum Fo/40 Hz Maximum Fo/2 Hz
Minimum 1 sec. Maximum 6 sec.
Minimum 0.1 sec.Maximum 25.5 sec.
Maximum breaking voltage 42 VMaximum breaking current 1 A AC, 60VAMaximum breaking current 1 A DC, 30W
No. of ports 1 M-NET Optical M-NET Optical
Communication speed 300-38400 BAUDMax. cable lenght 1 kmRecommended cable type 1 x 2 x 0.25 w/shieldTermination Build-inConnector 7-pin IP67 connector
Operation temperature -30 to +60 °CTransportation/Storage temperature -40 to +85 °CMax. relative humidity 95% no condensing
2000 m. above sea level (higher levels only by specialagreement with Mita-Teknik)
ConstructionDimensions (WxHxD) 175 x 80 x 60 mmWeight 0.680 Kg
Degree of ProtectionDegree of Protection IP67Standards EN50081-2 (CE)
EN61000-6-2 (CE)EN61000-4-5 (Surge)
Max. operation height
Permissible Ambient Conditions
Ports for Optional Serial Communication
Relay
Reaction time (depends on center frequency Fo)
Alarm Delay
Port for RS485 Communication
Current Consumption
Frequency Filter
Vibration Input
Frequency BandwithBW (80dB/decade) depends on the center frequency Fo. Selectable in 5 steps
condition monitoringWP4084 Vibration Analyser
MT_WP4084_DataSheet_R2_0
© 2012 Mita-Teknik. All rights reserved
Technical Data
Supply VoltageNominal 24 VDCAllowed range 21.6 to 26.4 VDC
Typical 80 mAMaximum 250 mA
Power ConsumptionTypical 1.9 WMaximum 6.6 W
Alarm level (acceleration) Minimum 0.100 m/s2 Maximum 3.000 m/s2 Minimum 0.010 g Maximum 0.300 gResolution 0.001Accuracy @ 25°C, typical <0.003 g
Frequency Range Minimum 0.10 Ηz Maximum 5.00 ΗzResolution 0.01 Hz
Minimum Fo/40 Hz Maximum Fo/2 Hz
Minimum 1 sec. Maximum 6 sec.
Minimum 0.1 sec.Maximum 25.5 sec.
Maximum breaking voltage 42 VMaximum breaking current 1 A AC, 60VAMaximum breaking current 1 A DC, 30W
No. of ports 1 M-NET Optical M-NET Optical
Communication speed 300-38400 BAUDMax. cable lenght 1 kmRecommended cable type 1 x 2 x 0.25 w/shieldTermination Build-inConnector 7-pin IP67 connector
Operation temperature -30 to +60 °CTransportation/Storage temperature -40 to +85 °CMax. relative humidity 95% no condensing
2000 m. above sea level (higher levels only by specialagreement with Mita-Teknik)
ConstructionDimensions (WxHxD) 175 x 80 x 60 mmWeight 0.680 Kg
Degree of ProtectionDegree of Protection IP67Standards EN50081-2 (CE)
EN61000-6-2 (CE)EN61000-4-5 (Surge)
Max. operation height
Permissible Ambient Conditions
Ports for Optional Serial Communication
Relay
Reaction time (depends on center frequency Fo)
Alarm Delay
Port for RS485 Communication
Current Consumption
Frequency Filter
Vibration Input
Frequency BandwithBW (80dB/decade) depends on the center frequency Fo. Selectable in 5 steps
condition monitoringWP4084 Vibration Analyser
MT_WP4084_DataSheet_R2_0
© 2012 Mita-Teknik. All rights reserved
Mita-Teknik Ordering Information
Order Number Order Name9724084XX without cable (more types) WP4084 Vibration Analyser
Accessories977005001 Cable with plug, 5 m. 977005008 Cable with plug, 8 m. 977005002 Cable with plug, 11 m.
977005205 2 x 2 x 0.5 mm2 ,TP cable with plug, 5 m. 977005210 2 x 2 x 0.5 mm2 ,TP cable with plug, 10 m. 977005215 2 x 2 x 0.5 mm2 ,TP cable with plug, 15 m.
Using shielded cables, it is not possible to use of relay out.
Twisted pair cable with shield (only RS485 communication)
condition monitoringWP4088 Accelerometer
MT_WP4088_DataSheet_R2_0
© 2012 Mita-Teknik. All rights reserved
External Accelerometer for the WP4086 •condition monitor
Designed for easy mounting•
The WP4088 AccelerometerIt is important that the corresponding measure-ment equipment is epuipped with a real analog differential input.
Hardware Compensation ValuesDue to the accelerometer internal are AC coupled, with a build-in highpass filter, the signal respons is not linear below 1 Hz. The highpass filter have a cut-off frequency on 0.1 Hz. The following con-pensation factors have to be integrated into the measuring unit.
Compensation Factor: 0.1 - 1.0 HzThe conpensation curve will follow a normal 1 pole high pass filter curve with a cut off frequency of 0.1 Hz.
condition monitoringWP4088 Accelerometer
MT_WP4088_DataSheet_R2_0
© 2012 Mita-Teknik. All rights reserved
Technical Data
Build-up
Grey 1 Signal +
6 Shields
2 Signal -
3 Overload
4 GND
5 +5.0 VDC
Housing
Rosa
Green
Yellow & white
Brown
Frequency[hz]0.10 0.20 0.30 0.40 0.50 0.60 0.700.800.90 1.00
Compensationvalue1.3578 1.0971 1.0435 1.0220 1.0120 1.0055 1.0014 1.0014 1.0010 1.0000
Power SupplyTypical 5V DC +/- 5%
Maximum 20 mA
Measurement RangeHorizontal direction 0-5.0 g peakVertical direction 0-4.0 g peakFrequency Range 1.0-5000 Hz +/- 3 dB
0.1-1.0 Hz +/-3 dBSensitivity 500 mV/g (differental voltage)
Operation temperature -20 to 60°CTransportation/Storage temperature -40 to 85°CMax. relative humidity 95% no condensation
2000 m. above sea level (higher levels only by specialagreement with Mita-Teknik)
ConstructionDimensions (W) 65 mmDiameter 30 mm hexagonWeight 0.150 kgMounting M8
StandardsStandards EN61000-4-2 (CE)
EN61000-6-2 (CE) EN61000-4-5 (Surge)
Current
Permissible Ambient Conditions
Max. operation height
condition monitoringWP4088 Accelerometer
MT_WP4088_DataSheet_R2_0
© 2012 Mita-Teknik. All rights reserved
Mita-Teknik Ordering Information
Order Number Order Name972408810 WP4088 Accelerometer, 5g, 10 m. PVC Cable
972408801 WP4088 Accellerometer, 5 g, 0.5 m.Cable, PVC97240881095 WP4088 Cable, 9.5m., PVC97240881145 WP4088 Cable, 14.5m., PVC
972408850 WP4088 Accelerometer, 5g, 10 m.Cable, Halogen free
972408802 WP4088 Accellerometer, 5 g, 0.5 m. Cable, Halogen free97240885095 WP4088 Cable, 9.5m. Halogen free
Consists of:
Consists of:
condition monitoringAccelerometer 100MV/G 80G 786A
MT_Accelerometer Model 786_DataSheet_R2_0
© 2012 Mita-Teknik. All rights reserved
Rugged design•
Corrosion resistant•
Hermetic seal•
Case isolated•
ESD protection•
Reverse wiring protection•
Mounting Instruction
(53 mm)
(3,8 mm)
(Ø = 22 mm)
Connector Pin FunctionShell groundA power/signalB commom
condition monitoringAccelerometer 100MV/G 80G 786A
MT_Accelerometer Model 786_DataSheet_R2_0
© 2012 Mita-Teknik. All rights reserved
Technical Data
DynamicSensitivity, ± 5 %, 25°C 100 mV/gAcceleration range 80 g peakAmplitude nonlinearity 1%Frequency response: ± 5 % 3 - 5000 Hz ± 10 % 1 - 9000 Hz ± 3 dB 0.5 - 14000 HzResonance frequency 30 kHzTransverse sensitivity, max 5 % of axialTemperature response: -50 °C -5% +120 °C 5%
Voltage source 18 - 30 VDC Current regulating diode 2 - 10 mA
Broadband 2.5 Hz to 25kHz 700 µg Spectral 10 Hz 10 µg/√Ηz 100 Hz 5 µg/√Ηz 1000 Hz 5 µg/√Ηz Output impedance, max 100 Ω Bias output voltage 12 VDC Grounding Case isolated, internally shielded
Temperature range -50 to 120 °CVibration limit 500 g peakShock limit 5000 g peakElectromagnetic sensitivity, equiv g, max 70 µg/gaussSealing HermeticBase strain sensitivity, max 0.0002 g/µstrain
Sensing element design PZT ceramic / shearWeight 90 gramsCase material 316L stainless steelMounting 1/4 - 28 UNF tapped holeOutput connector 2 pin, MIL-C-5015 styleMating connector R6 typeRecommend cabling J10 / J9T2A
Physical
ElectricalPower requirement:
Electrical noise, equiv g:
Environmental
condition monitoringAccelerometer 100MV/G 80G 786A
MT_Accelerometer Model 786_DataSheet_R2_0
© 2012 Mita-Teknik. All rights reserved
Mita-Teknik Ordering Information
Order Number Order Name8946030 Accelerometer 100MV/G 80G 786A9724600 ICP Acc. with stud & cable
Accessories9724610 ICP acc. cable, 10 m.7983120 Mounting stud SF8