woodworks concealed - select acousticwoodworks ® concealed ceiling systems technical guide key...

14
This booklet provides drawings, details, and specification information for WoodWorks Concealed ceilings. WOODWORKS ® Concealed Ceiling Systems Technical Guide Key Selection Attributes •  Define a space with rich, natural FSC ® -certified wood •    FSC chain of custody (CoC) certified WoodWorks products represent  responsible production and consumption practices from the forest  to the consumer •  California Air Resources Board (CARB) compliant •  Mix and match three standard panel sizes on the same project •    Narrow 1/4" reveal visual  •    Hook-on panels (for standard 15/16" suspension) provide safe and secure  downward accessibility •   Create continuous looks and clouds with new 6" veneer-wrapped and painted  aluminum trim available in six coordinating wood finishes and black •  Complete standard system from one manufacturer (grid/panels/trim) •    Shorter lead times and lower cost than custom millwork •    Factory edge banded for superior quality •    Five standard perforations available to enhance acoustical performance  and design aesthetics Applications •    Healthcare •  Office •  Education •  Hospitality and retail In this Booklet (also found on armstrong.com/woodworks) Page 1   Attributes and Applications Page 2-3  Installation Details Page 4-5  2' x 4' Panel Layout Options Pages 6-7  2' x 6' Panel Layout Options Pages 8-9  2' x 8' Panel Layout Options Pages 10-11  Multi-size Panel Layout Options Page 12-13  Trim Installation Details Between us, ideas become reality CEILING SYSTEMS

Upload: others

Post on 10-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

This booklet provides drawings, deta i ls , and speci f icat ion informat ion for WoodWorks Concealed cei l ings.

WOODWORKS ® Concealed

Cei l ing Systems Techn ica l Gu ide

Key Select ion Attr ibutes•  Define a space with rich, natural FSC®-certified wood•   FSC chain of custody (CoC) certified WoodWorks products represent  responsible production and consumption practices from the forest  to the consumer

•  California Air Resources Board (CARB) compliant•  Mix and match three standard panel sizes on the same project•   Narrow 1/4" reveal visual •   Hook-on panels (for standard 15/16" suspension) provide safe and secure 

downward accessibility•   Create continuous looks and clouds with new 6" veneer-wrapped and painted aluminum trim available in six coordinating wood finishes and black

•  Complete standard system from one manufacturer (grid/panels/trim)•   Shorter lead times and lower cost than custom millwork•   Factory edge banded for superior quality•   Five standard perforations available to enhance acoustical performance 

and design aesthetics

Appl icat ions•    Healthcare

•  Office

•  Education

•  Hospitality and retail

In th is Booklet (also found on armstrong.com/woodworks)

Page 1   Attributes and Applications

Page 2-3  Installation Details

Page 4-5  2' x 4' Panel Layout Options

Pages 6-7  2' x 6' Panel Layout Options

Pages 8-9  2' x 8' Panel Layout Options

Pages 10-11  Multi-size Panel Layout Options

Page 12-13  Trim Installation Details

B e t w e e n u s , i d e a s b e c o m e r e a l i t y ™

Ceiling SyStemS

I N S T A L L A T I O N D E T A I L S

Step 1: Select Panel Size

Step 2: Order T-bar Hooks Based on Panel Size

2

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

5

2 ' x 4 ' S I N G L E P A N E L L A Y O U T O P T I O N S

Staggered Pattern Assembly – Unperforated

Staggered Pattern Assembly – W2 Perforation

De t a i l   V i ew

2 ' x 6 ' P A N E L L A Y O U T O P T I O N S

Basic Assembly

6

To create this design, you will need to order:

Item Pieces

    5984W1 – 2' x 6' Unperforated Panel 8

    5986 – T-Bar Hooks (4 per Panel)     48 (6 per Panel)

HD Main Beams 6

2' Cross Tees 25

SH12 Support Hanger 3

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

2 ' x 6 ' S I N G L E P A N E L L A Y O U T O P T I O N S

Staggered Pattern Assembly – Unperforated

Staggered Pattern Assembly – W6 Perforation

7

De t a i l   V i ew

2 ' x 8 ' P A N E L L A Y O U T O P T I O N S

Basic Assembly

8

To create this design, you will need to order:

Item Pieces

    5985W1 – 2' x 8' Unperforated Panel 8

    5986 – T-Bar Hooks (4 per Panel)     64 (8 per Panel)

HD Main Beams 8

2' Cross Tees 35

SH12 Support Hanger    6

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

2 ' x 8 ' S I N G L E P A N E L L A Y O U T O P T I O N S

Staggered Pattern Assembly – Unperforated

Staggered Pattern Assembly – W3 Perforation

9

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

Reference Point

10

M U L T I - S I Z E P A N E L L A Y O U T O P T I O N S

Staggered Pattern Assembly – 2' x 4' and 2' x 6' Panels Unperforated

Staggered Pattern Assembly – 2' x 4' and 2' x 8' Panels Unperforated

Reference Point

Reference Point

Reference Point

Reference Point

11

M U L T I - S I Z E P A N E L L A Y O U T O P T I O N S

Staggered Pattern Assembly – 2' x 6' and 2' x 8' Panels Unperforated

12

T R I M I N S T A L L A T I O N D E T A I L S

Step 1: Cut and Miter Trim

Step 2: Attach Clips to Ends of Main Beams and Cross Tees Step 3: Attach Trim to Clips

120"

FinishedStandard

Trim Length

96-5/8"95-13/16"95-1/16"

72-5/8"71-13/16"71-1/16"

72-3/8"71-15/16"71-9/16"

4' LengthMitered onBoth Ends

47-1/16"

48-5/8"

47-13/16"T-Bar Hook Flange

Panel FlangeOutside Edges of Miter

6' LengthMitered on

One End

6' LengthMitered onBoth Ends

8' LengthMitered onBoth Ends

Black Powdercoat Finish

6.0"

FXTBC Location

Flange that alignsT-Bar Hook

Flangethat alignsPanel Edge

6"

FXTBC T-BarConnector Clip

XL7301BL12' HD Main Beam WW Concealed

Trim

FXTBC T-BarConnector Clip

13

Step 5: Install Panels

T R I M I N S T A L L A T I O N D E T A I L S

Step 4: Install Splice Plates

FX4SPLICESplice Plate

WW ConcealedTrim

FXTBC T-BarConnector Clip

XL7301BL12' HD Main Beam

WW ConcealedT-Bar Hook

For a basic cloud assembly with 2' x 6' panels, you will need to order: 

Item Pieces

59841W1 - 2' x 6' Unperforated Panel 65986 – T-Bar Hooks  36HD Main Beams 62' Cross Tees 101' Cross Tees 4SH12 Support Hanger 2FXTBC T-Bar Connector Clips 16FX4SPLICE Splice Plates 126603W1 Trim 6

1 877 ARMSTRONG (276-7876)

TechLine – Technical information

8 a.m. to 5:30 p.m. EST

Monday through Friday

FAX 1-800-572-8324 or

email: [email protected]

armstrong.com/woodworks

B e t w e e n u s , i d e a s b e c o m e r e a l i t y ™

Ceiling SyStemS

TechLineSM / 1 877 ARmSTRONG 1 877 276 7876

armstrong.com/woodworksCS-4274-1011

All trademarks used herein are the property of AWI Licensing Company and/or its affiliates© 2011 AWI Licensing Company  •  Printed in the United States of America