With 60 years of innovation, the Rosenberger brand now associates with the most advanced technology, highest quality and creativity, and as a world leading company in cellular technology and telecommunica-tions, data systems, medical electronics, industrial measurement tech-nology, automotive electronics, as well as electro-mobility fields. Rosen-berger also maintains 21 manufacturing bases and 8 R&D centers with branch and sales offices located all over the world.
With 60 years of innovation, the Rosenberger brand now associates with the most advanced technology, highest quality and creativity, and as a world leading company in cellular technology and telecommunica-tions, data systems, medical electronics, industrial measurement tech-nology, automotive electronics, as well as electro-mobility fields. Rosen-berger also maintains 21 manufacturing bases and 8 R&D centers with branch and sales offices located all over the world.
MISSION STATEMENT
CORE VALUE
PRODUCTPORTFOLIOS
Connectivity
FTTA / PTTA Radio Site SolutionEnterprise and Datacenter Cabling SolutionIntelligent Infrastructure Management SystemFTTx-PON Network SolutionFiber Optic and Data ConnectivityCustomized Fiber Optic and Hybrid Solution
Optical Infrastructure Solution
MISSION STATEMENT
CORE VALUE
PRODUCTPORTFOLIOS
Connectivity
FTTA / PTTA Radio Site SolutionEnterprise and Datacenter Cabling SolutionIntelligent Infrastructure Management SystemFTTx-PON Network SolutionFiber Optic and Data ConnectivityCustomized Fiber Optic and Hybrid Solution
Optical Infrastructure Solution
6
3
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
Released 3rd version of patented Pyixs Intelligent Infrastructure Management SystemRewarded as Huawei Excellent Core Partner at 9th timesRewarded as Tencent Excellent Partner at 3rd timesRewarded as China Top 10 Cabling Brand at the 8th times Rewarded as Huawei Excellent Core Partner at 8th timesRewarded as Tencent Excellent Partner at 2nd timesRewarded as China Top 10 Cabling Brand at the 7th times
Kunshan base, the largest operating base of Rosenberger in Asia , was formally put into operationRewarded as Huawei Excellent Core Partner at 4th timesRewarded as China Top 10 Cabling Brand at the 5th times
Released 2nd version of patented Rosenberger Pyxis Intelligent Infrastructure Management SystemRewarded as China Best Data Center Supplier at the 5th timesRewarded as Huawei Excellent Core Partner at the 4th timesRewarded as China Top10 Cabling Brand at the 3rd times
The 20th anniversary of Rosenberger Data Center Solution R&D and production base
Rewarded as China Top10 Cabling Brand Expanded production base for data center products in Taksony, Hungary
Rewarded as Huawei Excellent Core Partner
Rewarded as China Best Data Center SupplierReleased LC optical fiber connector and with mass production
Released pre-connect copper cable and with mass production
Set up 11 divisions and 4 logistic centers in Asia Pacific region
Released MU and SC optical fiber connectors and with mass production
Marketed MU connector, developed Preconnect cable seriesObtained ISO 16949 Quality System Certification
Rosenberger Shanghai Factory obtained IBM data center solution global certificationHDCS® network and data center cabling solution launched in Asia Pacific region
Rosenberger established new R&D and production base in Augsburg, GermanySet up new production factory in Beijing, ChinaSet up new production facility for fiber optics and premise cabling products in Shanghai, China
Developed MTP®/MPO pre-terminated trunk cable up to 114 cores
Rosenberger Asia Pacific obtained ISO 9001 Quality System and ISO 14001 Environment Certificates
Established production base for data center products in Taksony, HungaryRosenberger Asia Pacific found in Beijing, China
Started to supply pre-terminated trunk fiber cables for data center cabling system
Set up R&D and production base for data center cabling solutions in Ichenhausen, Germany
Rosenberger Data Center Cabling Solution Memorial Events2017
2016
2014
2012
2011
2010
2009
2008
2007
2005
2004
2003
2002
2001
2000
1999
1997
1995
1991
8
Content
HDCS® Data Center Solution
PAGE 10-11
HDCS® Architecture of Data Center Cabling Design
PAGE 12-13
HDCS® Characteristic Data Center Cabling Solution
PAGE 14-15
9
Benefits of HDCS® PRECONNECT®
Installation and Deployment
PAGE 18-19
HDCS® Quality Management System and ProductCertification
PAGE 16-17
HDCS® Data Center Cabling Solution Products
PAGE 20-53
Major Projects at a Glance
PAGE 54-57
10
HDCS® Data Center Solution
For over 25 years Rosenberger has provided innovative and exceptional Data Center Cabling Solutions for a variety of indus-tries: finance, telecommunications, internet service providers, government organizations, manufacturers, and airports.From medium-sized entities to Fortune-500 companies, these enterprises have trusted in Rosenberger Data Center Cabling Solutions to provide excellent performance, reliability, and security for critical data center application.
The development of Rosenberger’s PRECONNECT® trunk system is the cornerstone for cabling architecture and has been synonymous with decades of world-class expertise for state-of-art data center solutions.
Rosenberger Data Center Solutions comply with all relevant standards:
ANSI/TIA-942-B ANSI/TIA-568-DISO/IEC 24764ISO/IEC 11801EN 50173-5GB50174
Rosenberger Data Center Solutions support IEEE 802.3ba 40G/100G standard
Rosenberger has over 20 years expertise in Data Center Solutions
Green IT technology reduces CO2 emissions and power consumption to help minimize carbon footprint
All HDCS® data center products are individually tested
ALL HDCS® Fiber products with registered SN are traceable to manufacturing test data
PRECONNECT® system helps to avoid potential damage during installation and provides robust connectivity
MDA: The main distribution area is the primary space within the data center where the point of distribu-tion for the structured cabling system is located.
HDA: The horizontal distribution areas are spaces that support cabling to equipment such as LAN, SAN, Consoles, and KVM switches.
EDA: The equipment distribution area is the space allocated for end equipment, including computer systems and communications equipment.
ER1
ADMINISTRATION ROOM
MONITORDefinitions and Terms:
11
ER: The entrance room is the space used for the interface between the data center structured cabling system and inter-building ca-bling, both access provider and customer-owned.
Monitor/Support Area: The data center support areas are spaces outside the computer room that are dedicated to supporting the data center facility.
Administration/Office Area: Work area to support data center.
AC: Air Conditioning for computer room.
ER2
MONITOR
ACMDA
HDA EDA
12
HDCS® Architecture of Data Center Cabling DesignIn the first stage of a data center project, planning of the MDA is critical to allow for flexibility in possible future expansions. A ma-jority of customers will reserve 1x rack space in the MDA to allow for such expansion. The fiber and copper cabling are designed
Computer Room
Access Providers Access Providers
Backbone cabling
Backbone cabling
Backbone cabling
Backbone cabling
Backbone cabling
Backbone cabling
Backbone cabling
Backbone cabling
Backbone cabling
Backbone cablingBackb
one cab
ling
Horizontalcabling
Horizontalcabling
Horizontalcabling
Horizontalcabling
Horizontalcabling
Horizontalcabling
Horizontalcabling
Horizontalcabling
ZDAZDA
HDA(LAN/SAN/KVM Switches)
TR(Office & Operations Center
LAN Switches)
HDA(LAN/SAN/KVM Switches)
HDA(LAN/SAN/KVM Switches)
IDA(LAN/SAN Switches)
Secondary Entrance Room
(Carrier Equip & Demarcation)
HDA(LAN/SAN/KVM Switches)
HDA(LAN/SAN/KVM Switches)
IDA(LAN/SAN Switches)
MDA(Routers, Backbone LAN/SAN
Switches, PBX, M13 Muxes)
Primary Entrance Room
(Carrier Equip & Demarcation)
Work area in office;Operation Center;
Support Room
EDA(Rack/Cabinet)
EDA(Rack/Cabinet)
EDA(Rack/Cabinet)
EDA(Rack/Cabinet)
EDA(Rack/Cabinet)
separately for the MDA to allow for ease of cable management. Also, based on the size of the data center and user’s needs, the HDA and IDA could be optional.
For large size data center cabling applications, designers can refer to ANSI/TIA-942-B standard. A block diagram is listed below:
13
The Relationship Between Cabling Levels and
Topological Structure
According to TIA942-B, data centers are graded to four tiers according to their availability. As such, each tier is designed with different redundancy mecha-nisms to meet the availability criteria. (See figure below)
Tier1 Tier2 Tier3 Tier4
Availability 99.671% 99.749% 99.982% 99.995%
Yearly Downtime 28.8H 22.0H 1.6H 0.4H
Tier 1 requires a basic single cable route. Tier 2 requires an additional access provider. Tier 3 requires a minimum of two ERs with each ER having indepen-dent cabling ingress. TIA-942-B emphasizes that the physical distance be-tween individual ingress points should be more than 20 meters apart. For Tier 4, there are redundant MDA , IDA and HDA.
Comparison of EOR and TOR
There are 2 conventions for cabling: TOR (Top of Rack) and EOR (End of Rack). Often EOR is chosen for data center cabling deployments, due to potential for higher availability and ease of management. In an EOR configuration, usually the first rack in a row of racks is designated for HDA equipment which then manages the subsequent equipment within the same row.
EOR Cabling Advantage and Shortage
The key advantage of EOR is that the switch resource can be shared for an entire row providing a higher utilization rate compared with TOR. Also cable management between equipment and the access switch is more convenient allowing for ease of moves, adds, and changes. EOR does require an increased number of cables, thereby increasing the cabling costs with respect to TOR.In TOR configuration, the access switch is installed in the top of each rack and manages the equipment within the respective rack.
TOR Cabling Advantage and Shortage
The key advantage of TOR cabling is that it is generally simpler and cable lengths are shorter than in an EOR installation. TOR may be preferred in high-density applications and where frequent moves, adds, changes are not antici-pated, thereby keeping cabling costs to a minimum. However, the switch uti-lization rate is lower in this structure compared with EOR, resulting in unused resources.
Pic a
Pic b
Pic c
14
HDCS® Characteristic Data Center Cabling SolutionCabling the Cloud Sharing the Future
High Density Modular Fiber Patch PanelFor high density application areas such as MDA, IDA, etc. The 4HU modular panel supports a maximum 384 fiber cores with a slide structure design for easy management and maintenance.
Quick ReleaseTM Fiber Patch CordPatented Quick ReleaseTM patch cords with bend-insensitive fiber is designed for use in high density data center applications and provides installation and operating conveniences. A german-designed high-precision 3D surface geometry test ensures ex-ceptional fiber transmission performance.
For over 25 years, Rosenberger HDCS® has provided a range of data center cabling solutions that provide high density, modularity, reliability, and performance. In addition to providing world-class leading products, Rosenberger offers consultation services to guide customers in developing custom data center applications, planning for future growth/capabilities, and im-proving operational efficiencies.
15
Pre-terminated Bunched Copper CablePre-terminated bunched copper cable is suitable for modular data center deployments and ensures efficient installation and high bandwidth performance.
Hybrid Patch PanelOffered in 1HU height, it combines copper and fiber modules and for flexible interconnect within the EDA. It can be installed on a cable tray or under a raised floor.
Dust-proof Patch PanelApplied in the IDA, HDA, or EDA, the dust-proof patch panel uti-lizes a patented Pegasus “tool-less” keystone jack and offers dust/dirt ingress protection.
PRECONNECT® Fiber Trunk CablePRECONNECT® fiber trunk cable is mainly used within the data center back bone to connect MDA to IDA and HAD. Offering pre-terminations with reliable mechanical performance and excellent fiber transmission performance to support 40G/100G speeds.
17
HDCS® Quality Management System and Product Certification
DIN ISO 16949: 2009
DIN ISO 9001: 2008
DIN ISO 14001: 2008
In combination with our project-management and quality assurance procedures, certified according to international standards, this ensures that we can provide a range of high quality products and
Rosenberger is certified according to the following quality management system.
Rosenberger cabling system is also certified by third party lab.
Electrical Testing Laboratories
Underwriter Laboratories Inc
PVP Premium VerificationProgram of the GHMT
MII China Ministry of Information Industry Certification
Brazil ANATEL Laboratory Accreditation
Global Quality Management, Consistent Service Quality
a total solution to meet high-end customer needs, especially for large-scale applications such as new construction of a large enterprise data center and cloud computing data center.
18
Benefits of HDCS® PRECONNECT® Installation and DeploymentHigh-efficient PRECONNECT® SolutionsStatistics show that HDCS® PRECONNECT® solutions saves 80% on installation time compared to traditional methods under the same conditions.96 core fiber cable needs to be pre-terminated with connectors, 100 meter length, 2 operators.
Traditional Splicing SolutionCable laying for a 100 meter route: 1 hour96 Fibers - splicing, testing and ancillary work: 8 hoursTotal: 9 hours
HDCS® PRECONNECT® SolutionCable laying for a 100 meter route: 1 hourConnector connection and channel testing: 0.75 hoursTotal: 1.75 hours
19
Step 3 - Fiber Channel Test
In order to ensure correct installation and that de-sired fiber channel performance is achieved, it is recommended to test each fiber channel with a fiber power meter and OTDR. This is recommended for 10G or 40G/100G applications.
Step 1 – Laying PRECONNECT® Fiber
Trunk Cable
Laying the MTP terminated fiber connector PRECONNECT® trunk cable in the customer data center room according to the system design map. Laying the cable either under a floor or above in a cable tray on the rack is suitable for Rosenberger PRECONNECT® trunk cables. Each PRECONNECT® trunk ca-ble end is installed with protection & pulling sleeves, which can be directly and quickly pulled to the right area along the route.
Step 2 - PRECONNECT® Trunk
Connection
Refer to the PRECONNECT® trunk cable installation manual, remove the protection sleeves at each end of the trunk, connect the fiber optic connector to the rear of the fiber patch panels or equipment per transmission channel. No special tool or fusion splicing is required.
PRECONNECT® Solution 3-Step Deployment
21
HDCS® Data Center Cabling Solution Products
NormaTM Trunk Fiber cable 22
VelaTM Trunk Fiber Cable 24
NormaTM High Density Modular Fiber Patch Panel 26
VelaTM Data Center Pull-out Modular Fiber Patch Panel 28
TaurusTM III Data Center Modular Fiber Patch Panel 30
VelaTM Bridge-type Fiber Patch Panel 32
TaurusTM MTP/MPO-LC Harness cord 34
TaurusTM LC Fiber Patch Cord 35
TaurusTM MTP Patch Cord 37
FornaxTM Active Optical Cable 38
FornaxTM SFP+/QSFP+ Direct Attach Passive Copper Cables 40
TaurusTM I Hybrid patch Panel 41
TaurusTM II Modular 24 Ports FO-CU Hybrid Patch Panel 42
PegasusTM Pre-connect Copper Cable 43
ApusTM 48 Ports Patch Panel 44
ApusTM CAT6 UTP Copper Cabling System 46
ApusTM CAT6 FTP Copper Cabling System 48
DracoTM CAT6A UTP Copper Cabling System 50
DracoTM CAT6A FTP Copper Cabling System 52
22
HDCS® Data Center Cabling Solution Products
HDCS® PRECONNECT® Fiber solution
Applications• Used for fiber trunk connections between the MDA and IDA or
HDA, as well as from HDA to ZDA or EDA.
Features• NormaTM PreCONNECT® trunk cable is compatible with fiber
cores ranging from 12 to 144 for high-density application.• Convenient installation and re-location.• Each PreCONNECT® trunk cable end is installed with protec-
tion & pulling sleeves for crush-resistance, torsion-resistance, as well as water and dust proofing up to IP50 (indoor trunk). Up to 500N of pulling force can be applied to the PreCONNECT® trunk cable.
• Multi-mode OM2 50/125µm, 10G OM3 50/125µm, OM4 50/125µm, OM5 50/125µm and low water-peak single-mode G652D 9/125µm, G657A 9/125µm fiber options available for dif-ferent requirements.
• No splicing points within the entire PreCONNECT® trunk cable. Each fiber connector is tested in the Rosenberger factory for transmission and connectivity performance to ensure minimal insertion loss.
• PE, OFNR, OFNP or LSZH sheathed fiber cables are avail-able. LSZH rated fiber cable meets and passes IEC60332-1 and IEC60332-3 requirements, OFNR rated cable meets and passes UL-1666 requirements, and OFNP rated cable meets and passes UL-910 requirements.
NormaTM Trunk Fiber cable
23
HDCS® PRECONNECT® Fiber solution
NormaTM Trunk Fiber cable
Technical Parameters for Indoor NormaTM Trunk Cable
Number of Fiber Core 12 24 36 48 72 96 144
Length of Legs, cmMTP 86 86-90 86-94 86-98 86-106 86-106 86-106
LC-duplex 86-106
Fan-out Diameter, mm 16*17*105
Trunk Cable Max. Tensile Force-installation, N 500
Min. Bending Radius (Installation), mm 100 100 120 120 120 140 180
Min. Bending Radius (Operation), mm 50 50 60 60 60 70 90
Crush Resistance Cable, N/cm 800 800 800 800 800 800 800
Temperature Range (Installation) °C 0°C~+50°C
Temperature Range (Operation) °C -20°C~+60°C
NormaTM PRECONNECT® Trunk Fiber Cable Ordering Information
Indoor Classic Trunk Cable
X: Cable Jacket Type
X: Fiber Type X: Connector Type X: Fiber Cores
X: Polarity _ XXX: Cable Length
23: Norma
3: LSZH1: G652D 9/125µm
7: LC/LC 4:12 core(C): TIA568 Type C (MTP or LC)
_
005:5m
6: OFNR2: 50/125µm OM2
F:MPO(F)/MPO(F) 6:24 core A: TIA568 Type B(MTP) 010:10m
8: OFNPA: 50/125µm OM3
J: MPO(M)/LC 7:36 core S: TIA568 Type A(MTP) 015:15m
B: 50/125µm OM4
M: MPO(F)/LC 8:48 core J: TIA568 Type C(MPO) 020:20m
D: 50/125µm OM5
L: MPO(M)/MPO(M) 9:72 coreF: TIA568 Type B(MPO)
025:25m
8: G657A 9/125µm
0:96 core Z: TIA568 Type A(MPO) 030:30m
A:144 core …
NormaTM PreCONNECT® Trunk Fiber Cables are ordered using 10 digits: Digit1 and Digit2, NormaTM type trunk cable; Digit3, Cable jacket selection; Digit4, Fiber type selection; Digit5 connector type selection; Digit6, fiber cores selection; Digit7, polarity, MPO con-nector or US Conec MTP® connector; Digit8 to Digit10, Cable length selection. Example: 233174-025 Norma Trunk, LSZH jacket, SM G652D, LC-LC, 12core, TIA568 Type C, 25m 233BL4A-100 Norma Trunk, LSZH jacket, MM OM4, MTP(M)-MTP(M), 12core, TIA568 Type B, 100m
24
VelaTM Trunk Fiber Cable
HDCS® PRECONNECT® Fiber Solution
OM4 , 50/125um OM5 and low water-peak single-mode of 9/125um G652D and 9/125um G657A fiber options available for different requirements
• No splicing points within the entire PreCONNECT® trunk cable, and each pre-terminated fiber connector is tested in the Rosen-berger factory for transmission and connectivity performance to ensure minimal insertion loss
• PE, OFNR, OFNP or LSZH sheathed fiber cables are avail-able. LSZH rated fiber cable meets and passes IEC60332-1 and IEC60332-3 requirements, OFNR rated cable meets and passes UL-1666 requirements, and OFNP rated cable meets and passes UL-910 requirements
Applications• Used for fiber trunk connections between the MDA and IDA or
HDA, as well as from HDA to ZDA or EDA.
Features• VelaTM PreCONNECT® trunk cable is compatible with12 fiber
cores • Convenient installation and re-location• Provides smaller bend radius trunk cable for high density ca-
bling application in data center• Each PreCONNECT® trunk cable end is installed with protec-
tion & pulling sleeves for protect terminated connectors• Multi-mode of 50/125um OM2, 10G 50/125µm OM3, 50/125um
HDCS® Data Center Cabling Solution Products
25
Technical Parameters of Indoor VelaTM PRECONNECT® Trunk Cable
Number of Fiber Core
Fiber Cable Diameter
Min. Bending Radius (mm)
Crush Resistance Cable (N/10cm)
Trunk Cable Max. Ten-sile Force-installation, N
Temperature Range(°C)
Operation Installation Long Term Short Term Long Term Short Term Installation Operation
4-12 4.5 45 90 250 750 150 300 0°C~+50°C -20°C~+60°C
VelaTM PRECONNECT® Trunk Fiber Cable Ordering Information
Indoor Trunk Cable
X: Cable Jacket Type
X: Fiber Type
X: Connector Type
X: Fiber Cores
X: Polarity — XXX: Cable Length
21: Vela
3: LSZH1: G652D 9/125µm
F:MPO(F)/MPO(F)
4:12 core (C): TIA568 Type C(MTP) 005:5m
6: OFNR2: 50/125µm OM2
L: MPO(M)/MPO(M)
A: TIA568 Type B(MTP) 010:10m
8: OFNPA: 50/125µm OM3
P: MPO(M)/MPO(F)
S: TIA568 Type A(MTP) 015:15m
B: 50/125µm OM4
J: TIA568 Type C(MPO) 020:20m
D: 50/125µm OM5
F: TIA568 Type B(MPO) 025:25m
8: G657A 9/125µm
Z: TIA568 Type A(MPO) 030:30m
VelaTM PreCONNECT® Trunk Fiber Cables are ordered using 10 digits: Digit1 and Digit2, NormaTM type trunk cable; Digit3, Cable jacket selection; Digit4, Fiber type selection; Digit5 connector type selection; Digit6, fiber cores selection; Digit7, polarity, MPO con-nector or US Conec MTP® connector; Digit8 to Digit10, Cable length selection. Example: 2131F4-025 Vela Trunk, LSZH Jacket, SM G652D, MTP(F)-MTP(F), 12core, TIA568 Type C, 25m213BL4A-100 Vela Trunk, LSZH Jacket, MM OM4, MTP(M)-MTP(M), 12core, TIA568 Type B, 100m
VelaTM Trunk Fiber Cable
HDCS® PRECONNECT® Fiber solution
26
MTP-LC Module
1HU NormaTM Fiber Patch Panel
LC Adapter Plate MTP/MPO Adapter Plate
4HU NormaTM Fiber Patch Panel
Applications• NormaTM high density modular fiber patch panels are used
in MDA, IDA or HDA for fiber cable distribution and manage-ment.
Features• A maximum of 12 and 48 sets of the NormaTM module/front
plate can be installed on each 1HU and 4HU modular patch panel respectively.
• 1HU panel can reach up to 144 f ibers (LC) and 576 fibers(MTP). 4HU panel can reach up to 576 fibers(LC) and 2304 fibers(MTP).
• The connectivity capacity can be up to 12 fibers for each mod-ule and front plate with an LC interface.
• PreCONNECT® fiber module accepts multi-mode 50/125um OM2, OM3, OM4, OM5 or a low water- peak single-mode 9/125um fiber cable harness.
• Modular structure on patch panel is innovated and designed with a pull-out feature for quick and safe PreCONNECT® trunk fiber cable installation and maintenance.
• Label panel has hidden drawer design, it can hang downwards after pull-out for better observation.
Technical Parameters• The outer shape of the patch panel complies with ETSI 1HU
and 4HU standards• Salt mist cyclic test (24H)• Attenuation (Typical): single-mode MTP-LC module 0.5dB, mul-
timode MTP-LC module 0.4dB• Storage temperature: -40°C ~ +70°C• Operation temperature: -20°C ~ +60°C
Relative Standards• ANSI/TIA-942-B• ANSI/TIA-568-D.3• ISO/IEC 24764• ISO/IEC 60794• ISO/IEC 61754• EN 50173-5
NormaTM High Density Modular Fiber Patch Panel
HDCS® Data Center Cabling Solution Products
HDCS® PRECONNECT® Fiber Solution
27
NormaTM Ι Data Center Modular Fiber Patch Panel
NormaTM Modular Fiber Patch Panel Ordering Information
Ordering Number Description
NormaTM Fiber Patch Panel
CPB1-150-21 NormaTM 1HU high density FO modular patch panel without module (max 144F)
CPB1-150-61 NormaTM 4HU high density FO modular patch panel without module (max 576F)
MTP/MPO(Female)-LC Module, Type A
CPB2-A61-11 NormaTM 12F module A, G652D MTP(F)-LC
CPB2-A63-11 NormaTM 12F module A, OM2 MTP(F)-LC
CPB2-A64-11 NormaTM 12F module A, OM3 MTP(F)-LC
CPB2-A65-11 NormaTM 12F module A, OM4 MTP(F)-LC
CPB2-A66-11 NormaTM 12F module A, OM5 MTP(F)-LC
CPB2-A61-31 NormaTM 12F module A, G652D MPO(F)-LC
CPB2-A63-31 NormaTM 12F module A, OM2 MPO(F)-LC
CPB2-A64-31 NormaTM 12F module A, OM3 MPO(F)-LC
CPB2-A65-31 NormaTM 12F module A, OM4 MPO(F)-LC
CPB2-A66-31 NormaTM 12F module A, OM5 MPO(F)-LC
MTP/MPO(Female)-LC Module, Type B
CPB2-A61-12 NormaTM 12F module B, G652D MTP(F)-LC
CPB2-A63-12 NormaTM 12F module B, OM2 MTP(F)-LC
CPB2-A64-12 NormaTM 12F module B, OM3 MTP(F)-LC
CPB2-A65-12 NormaTM 12F module B, OM4 MTP(F)-LC
CPB2-A66-12 NormaTM 12F module B, OM5 MTP(F)-LC
CPB2-A61-32 NormaTM 12F module B, G652D MPO(F)-LC
CPB2-A63-32 NormaTM 12F module B, OM2 MPO(F)-LC
CPB2-A64-32 NormaTM 12F module B, OM3 MPO(F)-LC
CPB2-A65-32 NormaTM 12F module B, OM4 MPO(F)-LC
CPB2-A66-32 NormaTM 12F module B, OM5 MPO(F)-LC
Adapter Plate
CPB4-345-51 NormaTM MTP Adapter plate with 4Pcs MTP adapter, Up/Up
CPB4-347-51 NormaTM MTP Adapter plate with 4Pcs MTP adapter, Up/Up
CPB4-242-21 NormaTM LC Adapter plate with 6Pcs blue LC duplex adapter
CPB4-243-21 NormaTM LC Adapter plate with 6Pcs aqua LC duplex adapter
Blind Cover
CPB4-041-11 NormaTM blind cover
28
1HU VelaTM Patch Panel
MTP-LC Module LC Adapter Plate MTP/MPO Adapter Plate Blind Cover
VelaTM Data Center Pull-out Modular Fiber Patch Panel
Applications• 1HU, 4HU modular fiber patch panels are used in MDA, IDA or
HDA for fiber Cable distribution and management.
Features• Modular and ergonomic design with front and rear drawers for
ease of installation and maintenance.• •1HU and 4HU could handle 96 fibers and 288 fibers respec-
tively.• The connectivity capacity can be up to 12 fibers for each mod-
ule and front plate with an LC interface.• P r e C O N N E C T ® f i b e r m o d u l e a c c e p t s m u l t i - m o d e
50/125umOM2, OM3, OM4, OM5 or a low water- peak single-mode9/125um fiber cable harness.
• Rear cabling manager with layered design and pull-out rotation function.
• Label panel has hidden drawer design, it can hang downwards after pull-out for better observation.
Technical ParametersThe outer shape of the patch panel complies with ETSI 1HU and 4HU standards.Salt mist cyclic test (24H).Attenuation (Typical): single-mode MTP-LC module 0.5dB, multi-mode MTP-LC module 0.4dB.Storage temperature: -40°C ~ +70°C.Operation temperature: -20°C ~ +60°C.
Relative Standards• ANSI/TIA-942-B• ANSI/TIA-568-D.3• ISO/IEC 24764• ISO/IEC 60794• ISO/IEC 61754• EN 50173-5
HDCS® Data Center Cabling Solution Products
4HU VelaTM Patch Panel
29
VelaTM Data Center Modular Fiber Patch Panel Ordering Information
Ordering Number Description
VelaTM Fiber Patch Panel
CPB1-730-41 VelaTM 1HU High density fiber patch panel without module (8Pcs 40G module available)
CPB1-730-61 VelaTM 4HU High density fiber patch panel without module (24Pcs 40G module available)
MTP/MPO(Female)-LC Module, Type A
CPB2-A51-11 VelaTM 12F module A, G652D MTP(F)-LC
CPB2-A53-11 VelaTM 12F module A, OM2 MTP(F)-LC
CPB2-A54-11 VelaTM 12F module A, OM3 MTP(F)-LC
CPB2-A55-11 VelaTM 12F module A, OM4 MTP(F)-LC
CPB2-A56-11 VelaTM 12F module A, OM5 MTP(F)-LC
CPB2-A51-31 VelaTM 12F module A, G652D MPO(F)-LC
CPB2-A53-31 VelaTM 12F module A, OM2 MPO(F)-LC
CPB2-A54-31 VelaTM 12F module A, OM3 MPO(F)-LC
CPB2-A55-31 VelaTM 12F module A, OM4 MPO(F)-LC
CPB2-A56-31 VelaTM 12F module A, OM5 MPO(F)-LC
MTP/MPO(Female)-LC Module, Type B
CPB2-A51-12 VelaTM 12F module B, G652D MTP(F)-LC
CPB2-A53-12 VelaTM 12F module B, OM2 MTP(F)-LC
CPB2-A54-12 VelaTM 12F module B, OM3 MTP(F)-LC
CPB2-A55-12 VelaTM 12F module B, OM4 MTP(F)-LC
CPB2-A56-12 VelaTM 12F module B, OM5 MTP(F)-LC
CPB2-A51-32 VelaTM 12F module B, G652D MPO(F)-LC
CPB2-A53-32 VelaTM 12F module B, OM2 MPO(F)-LC
CPB2-A54-32 VelaTM 12F module B, OM3 MPO(F)-LC
CPB2-A55-32 VelaTM 12F module B, OM4 MPO(F)-LC
CPB2-A56-32 VelaTM 12F module B, OM5 MPO(F)-LC
Data Center Splicing Module
CPB2-553-11 VelaTM 12F LC Splicing module with LC adapter without pigtail
Adapter Plate
CPB4-335-51 VelaTM MTP Adapter plate with 4Pcs MTP adapter Up/Up
CPB4-337-51 VelaTM MPO Adapter plate with 4Pcs MTP adapter Up/Up
CPB4-232-21 VelaTM LC Adapter plate with 6Pcs LCD SM adapter
CPB4-233-21 VelaTM LC Adapter plate with 6Pcs LCD OM3 adapter
Blind Cover
CPB4-611-11 VelaTM Blind Cover
VelaTM Data Center Pull-out Modular Fiber Patch Panel
30
TaurusTM Ⅲ Data Center Modular Fiber Patch Panel
Applications• 1HU, 4HU TaurusTM Ⅲ modular fiber patch panels are used in
MDA, IDA or HDA for fiber cable distribution and management.
Features• High density and modular design, suitable for upgrade• 1HU panel body accommodates 4 modules and supports max.
96-core fibers (LC connector) and 384-core fibers (MTP con-nector) connectivity.
• 4HU panel body accommodates 12 modules and supports max. 288-core fibers (LC connector) and 1152-core fibers (MTP con-nector)
• Connectivity.• MTP-LC, MTP-MTP and LC-LC modules with different density
are available to achieve most flexible and optimized configura-tion.
• Distinctive rear cabling cable storage and management design provide wider operation space for best maintainability.
• Front plate of panel is made of a special transparent mate-rial designed for fiber cable protection and convenient system maintenance.
• Both 4U and 1U panel are with horizontal cable management
ring to facilitate patch cord management.• The patent hidden label system makes the product more tidy
and practical.• Both side or rear cable installation are available.• Compatible with10G/40G/100G /400G applications.
Technical Parameters• The outer shape of the patch panel complies with ETSI 1HU
and 4HU standards.• Salt mist cyclic test (24H).• Attenuation (Typical): single-mode MTP-LC module 0.5dB,
multi-mode MTP-LC module 0.4dB.• Storage temperature: -40°C ~ +70°C.• Operation temperature: -20°C ~ +60°C.
Relative StandardsANSI/TIA-942-BANSI/TIA-568-D.3ISO/IEC 24764ISO/IEC 60794ISO/IEC 61754EN 50173-5
HDCS® Data Center Cabling Solution Products
1HU TaurusTM Ⅲ Modular Patch Panel
MTP-LC Module MTP Adapter Plate LC Adapter Plate Blind Plate
4HU TaurusTM Ⅲ Modular Patch Panel
31
TaurusTM Ⅲ Modular Fiber Patch Panel Ordering InformationOrdering Information Description
TaurusTM Ⅲ Fiber Patch Panel
CPB1-120-61 TaurusTM Ⅲ Modular Patch Panel Box, Grey, 4HU
CPB1-120-21 TaurusTM Ⅲ Modular Patch Panel Box, Grey, 1HU
TaurusTM Ⅲ MTP/MPO(Female)-LC A module
CPB2-A41-11 TaurusTM Ⅲ Module-A,MTP(F)-LC,24F,9/125μm SM
CPB2-A43-11 TaurusTM Ⅲ Module-A,MTP(F)-LC,24F,OM2 50/125μm MM
CPB2-A44-11 TaurusTM Ⅲ Module-A,MTP(F)-LC,24F,OM3 50/125μm MM
CPB2-A45-11 TaurusTM Ⅲ Module-A,MTP(F)-LC,24F,OM4 50/125μm MM
CPB2-A46-11 TaurusTM Ⅲ Module-A,MTP(F)-LC,24F,OM5 50/125μm MM
CPB2-A41-31 TaurusTM Ⅲ Module-A,MPO(F)-LC,24F,9/125μm SM
CPB2-A43-31 TaurusTM Ⅲ Module-A,MPO(F)-LC,24F,OM2 50/125μm MM
CPB2-A44-31 TaurusTM Ⅲ Module-A,MPO(F)-LC,24F,OM3 50/125μm MM
CPB2-A45-31 TaurusTM Ⅲ Module-A,MPO(F)-LC,24F,OM4 50/125μm MM
CPB2-A46-31 TaurusTM Ⅲ Module-A,MPO(F)-LC,24F,OM5 50/125μm MM
TaurusTM Ⅲ MTP/MPO(Female)-LC B module
CPB2-A41-12 TaurusTM Ⅲ Module-B,MTP(F)-LC,24F,9/125μm SM
CPB2-A43-12 TaurusTM Ⅲ Module-B,MTP(F)-LC,24F,OM2 50/125μm MM
CPB2-A44-12 TaurusTM Ⅲ Module-B,MTP(F)-LC,24F,OM3 50/125μm MM
CPB2-A45-12 TaurusTM Ⅲ Module-B,MTP(F)-LC,24F,OM4 50/125μm MM
CPB2-A46-12 TaurusTM Ⅲ Module-B,MTP(F)-LC,24F,OM5 50/125μm MM
CPB2-A41-32 TaurusTM Ⅲ Module-B,MPO(F)-LC,24F,9/125μm SM
CPB2-A43-32 TaurusTM Ⅲ Module-B,MPO(F)-LC,24F,OM2 50/125μm MM
CPB2-A44-32 TaurusTM Ⅲ Module-B,MPO(F)-LC,24F,OM3 50/125μm MM
CPB2-A45-32 TaurusTM Ⅲ Module-B,MPO(F)-LC,24F,OM4 50/125μm MM
CPB2-A46-32 TaurusTM Ⅲ Module-B,MPO(F)-LC,24F,OM5 50/125μm MM
Front Plate
CPB4-222-22 TaurusTM Ⅲ LC 12F Front Plate With Adapter, SM
CPB4-223-22 TaurusTM Ⅲ LC 12F Front Plate With Adapter, MM
CPB4-222-32 TaurusTM Ⅲ LC 24F Front Plate With Adapter, SM
CPB4-223-32 TaurusTM Ⅲ 24F Front Plate With Adapter, MM
CPB4-325-22 TaurusTM Ⅲ MTP Up/Up 6 Port Front Plate With Adapter
CPB4-325-42 TaurusTM Ⅲ MTP Up/Up 8 Port Front Plate With Adapter
CPB4-327-22 TaurusTM Ⅲ MPO Up/Up 6 Port Front Plate With Adapter
CPB4-327-42 TaurusTM Ⅲ MPO Up/Up 8 Port Front Plate With Adapter
Blind Plate
CPB4-911-12 TaurusTM Ⅲ Blind Front Plate
32
VelaTM Bridge-type Fiber Patch Panel
Bridge-type Fiber Patch Panel (Installed under the bridge) 12F MTP-LC Module
Applications• 1HU 96F VelaTM bridge-type fiber patch panel is used in MDA,
IDA or HDA for fiber cable distribution and management• A maximum of 8 set of the VelaTM 12F module, 1HU VelaTM
bridge-type fiber patch panel can be installed 96 cores• Supplied the mounting bracket, bridge-type fiber patch panel • Can be installed on the bridge or under the bridge
Features• Easy installation and maintenance, the maximum capacity that
can reach up to 96 fibers with two layers, 8 set of the VelaTM 12F module.
• 12F MTP-LC module and 12F LC adapter front plate are avail-able for the patch panel.
• VelaTM 12F fiber module is defined respectively by using multi-mode 50/125um OM2, OM3, OM4, OM5 or a low water- peak single-mode 9/125um fiber cable harness inside.
• The front panel can be flipped 180 degrees downward, with la-bels.
• No separate installation horizontal cable manager, the patch panel can manage the wiring by itself.
• Dedicated pre-connection splitter fixing accessories protect pre-connection trunk
Parameters• The outer shape of the patch panel complies with ETSI 1HU
standard• Salt mist cyclic test (24H)• Attenuation (Typical): single-mode MTP-LC module 0.5dB,
multi-mode MTP-LC module 0.4dB• Storage temperature: -40°C ~ +70°C• Operation temperature: -20°C ~ +60°C
Standards• ANSI/TIA-568-D.3• ISO/IEC 60794• ISO/IEC 61754• EN 50173-5• GB 50174
HDCS® Data Center Cabling Solution Products
33
VelaTM Bridge-type Fiber Patch Panel
VelaTM Data Center Bridge-type Patch Pane Ordering InformationOrdering Number Description
VelaTM Fiber Patch Panel
CPB1-730-41 VelaTM Fiber Patch Panel, Black, without Module
Bridge Mounting Bracket
CP46-120-12 2HU rotating bridge mounting bracket
CP46-120-14 4HU rotating bridge mounting bracket
MTP/MPO(Female)-LC Module, Type A
CPB2-A51-11 VelaTM 12F module A, G652D MTP(F)-LC
CPB2-A53-11 VelaTM 12F module A, OM2 MTP(F)-LC
CPB2-A54-11 VelaTM 12F module A, OM3 MTP(F)-LC
CPB2-A55-11 VelaTM 12F module A, OM4 MTP(F)-LC
CPB2-A56-11 VelaTM 12F module A, OM5 MTP(F)-LC
CPB2-A51-31 VelaTM 12F module A, G652D MPO(F)-LC
CPB2-A53-31 VelaTM 12F module A, OM2 MPO(F)-LC
CPB2-A54-31 VelaTM 12F module A, OM3 MPO(F)-LC
CPB2-A55-31 VelaTM 12F module A, OM4 MPO(F)-LC
CPB2-A56-31 VelaTM 12F module A, OM5 MPO(F)-LC
MTP/MPO(Female)-LC Module, Type B
CPB2-A51-12 VelaTM 12F module B, G652D MTP(F)-LC
CPB2-A53-12 VelaTM 12F module B, OM2 MTP(F)-LC
CPB2-A54-12 VelaTM 12F module B, OM3 MTP(F)-LC
CPB2-A55-12 VelaTM 12F module B, OM4 MTP(F)-LC
CPB2-A56-12 VelaTM 12F module B, OM5 MTP(F)-LC
CPB2-A51-32 VelaTM 12F module B, G652D MPO(F)-LC
CPB2-A53-32 VelaTM 12F module B, OM2 MPO(F)-LC
CPB2-A54-32 VelaTM 12F module B, OM3 MPO(F)-LC
CPB2-A55-32 VelaTM 12F module B, OM4 MPO(F)-LC
CPB2-A56-32 VelaTM 12F module B, OM5 MPO(F)-LC
Data Center Splicing Module
CPB2-553-11 VelaTM 12F LC Splicing module with LC adapter without pigtail
Adapter Plate
CPB4-335-51 VelaTM MTP Adapter plate with 4Pcs MTP adapter Up/Up
CPB4-337-51 VelaTM MPO Adapter plate with 4Pcs MTP adapter Up/Up
CPB4-232-21 VelaTM LC Adapter plate with 6Pcs LCD SM adapter
CPB4-233-21 VelaTM LC Adapter plate with 6Pcs LCD OM3 adapter
Blind Cover
CPB4-611-11 VelaTM Blind Cover
34
Parameters• Fiber type: OM2, OM3, OM4, OM5, G652D• Fire redundant: LSZH, OFNR, OFNP• Max. insert loss: 0.5dB(MM); 0.7dB(SM)• Working temperature: -10°C ~ +60°C• Minimum fiber bending radius: <30mm
Standards• IEC 61754-7• IEC 61754-20• IEC 61300-3-4• ISO/IEC 11801• ANSI/TIA-568-D
Applications• Provide connection between Equipment with LC connector and
MTP type trunk cable• Provide connection between Equipment with MTP connector
and LC type trunk cable• Datacenter MDA, EDA
Features• Supports custom lengths• The number of harness cord is optional• 40G/100G application• LC connector polarity inversion optional• Low attenuation loss• 100% tested• Easy Plug&Play installation and maintenance •
TaurusTM MTP/MPO-LC Harness cord
Ordering Information
Dig-it1-2
Digit3-4 Digit5 Digit6
—
Digit7-8 Digit9-10
—
Dig-it11-12
Digit13 Digit14-17
Har-ness
XX: Fiber Count
X: Jacket Material
X: Fiber Type
XX: Connector (Left)
XX: Con-nector (Right)
XX: Branch Length
X: Polarity X X X X : Length
HA 04=4F H=LSZH 2=OM2 MP=MPO(Male) LC=LC 05: 0.5m A=TIA 568 A 0005=0.5
08=8F R=OFNR G=OM3 MF=MTP(Female) LD=LCD 15: 1.5m B=TIA 568 B 0030=3
12=12F P=OFNP H=OM4 MS=MPO(Male) LU=LC Uniboot
20: 2m C=TIA 568 C 0120=12
J=OM5 MK=MPO(Female) D=40G-4*10G
9=G652D
Rosenberger MTP-LC Harness cords are ordered using 17 digits: Digit 1-2, Harness cord; Digit 3-4, the number of cores; Digit 5, Outer sheath material or flammability class; Digit 6, fiber type; Digit 7-8, MTP connector type selection; Digit 9-10, Branch connector type; Digit 11-12, Branch length; Digit 13, Fiber polarity; Digit 14-17, Length selection. PN Example: HA12RG-MPLD-A0050 Harness, 12F, OM3, MTP(M)-LCD, Type A, OFNR,5M
HDCS® Data Center Cabling Solution Products
35
Parameters• Comply with: IEC 61754-20, IEC 61300-3-4, IEC 61300-3-6• Storage temperature: -25°C ~ +70°C• Working temperature: -5°C ~ +70°C•
Delivery• Patch cord separately packed in plastic bag• Labeled with serial number•
Standards• ANSI/TIA-568-D.3• ISO/IEC 11801
Applications• Between fiber patch panels• Between fiber patch panel and equipment with fiber
connection• Between equipment with fiber connection
Features• Fire redundant: LSZH, OFNR, OFNP• Duplex mode: Full duplex• Custom lengths• Fiber type: OM2, OM3, OM4, OM5, G652D• 100% performance tested and very low attenuation• Uniboot fiber patch cord can be reversed A/B polarity• Quick-release fiber patch cord can be plug quickly
without tools in high-density space
TaurusTM LC Fiber Patch Cord
LC Uniboot Fiber Patch Cord
LC Quick-Release Fiber Patch Cord
HDCS® Data Center Cabling Solution Products
36
TaurusTM LC Fiber Patch Cord
TaurusTM LC Patch cord Ordering Information
98C
Digit4 Digit5 Digit6 Digit7 Digit8 Digit9 Digit10 Digit11-14
X X X X X X X XXXX
S:G652D OFNR 2:2.0mm 3: Duplex Patch Cord 1:UPC-UPC(SM)
4: LC 4: LCM: Meter
Cable LengthXXX.X meter or XXX.X feet
E: G652D LSZH 5: Duplex Patch Cord (Separately)T: G652D OFNP
5:UPC-UPC(MM)
F: Feet
G: OM3 OFNR
6: UnibootH: OM3 LSZH
N: OM3 OFNP
V: OM4 OFNRA: Duplex Quick Re-lease
X: OM4 LSZH
W: OM4 OFNP
Q: OM5 OFNR
K: OM5 LSZH
R: OM5 OFNP
Rosenberger patch cords and pigtails are ordered using 14 digits: Digit4, fiber type selection; Digit5, cable diameter selection; Digit6, connector type selection; Digit7, polishing level selection for SM or core diameter selection for MM; Digit8& Digit9, connectortype selection; Digit10, Unit of length; Digit11-14, length selection, the format and digits are listed below.Example: 98CG23544M0030 Patch cord, OM3, OFNR, 2.0mm, UPC-UPC, LC-LC, 3meters
37
Applications• Used for datacenter fiber cabling, providing connection between
equipment and MTP patch panel• Used for 40G and 100G when the equipment adopts multichan-
nel parallel transmit technology
Features• MTP patch cord adopts 12 core MTP connector at both sides• Quick and convenient installation; improved and simplified fiber
routing• Multi-mode OM2, OM3, OM4, OM5, low water-peak single-
mode 9/125um G652D and 9/125um G657A fiber options avail-able to support a variety of applications
• Each MTP patch cord is tested in the Rosenberger factory for transmission and connectivity performance to ensure uniformity for12 core fibers and minimal average insertion loss
• MTP fiber optical connector exceeding requirement of durabil-ity single mode 500 mattings and multi-mode 1000 mattings in EIA/TIA-455-21A
• OFNR, OFNP or LSZH sheathed fiber cables are available. LSZH rated fiber cable meets and passes IEC60332-1 and IEC60332-3 requirements, OFNR rated cable meets and pass-es UL-1666 requirements, and OFNP rated cable meets and passes UL-910 requirements
Standards• IEC 61754-7• IEC 61754-20• IEC 61300-3-4• ISO/IEC 11801• ANSI/TIA-568-D
TaurusTM MTP Patch Cord
TaurusTM MTP/MPO Patch cord Ordering InformationDigit 1-2 Digit 3-4 Digit 5 Digit 6 — Digit 7-8 Digit 9-10 — Digit 11 Digit 12-15
TaurusTM MTP/MPOPatch cord
XX: Fiber X: Cable Jacket Type X: Fiber Type
—
XX: Connector XX: Connector Type
—
X: Polarity XXXX: Cable
04:4 core H: LSZH G: OM3 MP: MTP(Male)
MP: MTP(Male)
A: TIA568 Type A 0005:0.5M
MS 06:6 core R: OFNR H: OM4 MF: MTP(Female)
MF: MTP(Female)
B: TIA568 Type B 0100:10M
08:8 core P: OFNP J: OM5 MS: MPO(Male)
MS: MPO(Male)
C: TIA568 Type C 0150:15M
12:12 core 9: G652D MK:MPO
(Female)MK: MPO(Female) 0200:20M
A: G657A2 0250:25M
MTP patch cords are ordered using 15 digits: Digit1 and Digit2, TaurusTM MTP patch cord; Digit3 and Digit4, fiber cores selection; Digit5,cable jacket selection; Digit6, fiber type selection; Digit7 and Digit8, connector type selection on one end; Digit9 and Digit10, connector type on another end; Digit 11, polarity; Digit12 to Digit15, cable length selection,Example: MS12RG-MFMF-B0030 MTP Patch cord, 12F, OFNR, OM3, MTP(F)-MTP(F), type B, 3meters
TaurusTM MTP-MTP Patchcord Technical ParametersSingle-mode(8º) Multi-mode
Insertion Loss (Typical dB) 0.6 0.5
Standards EIA/TIA-455-21A IEC-61754-7 TIA-604-5
Temperature Range (Installation) °C -5°C~ 50°C
Temperature Range (Operation) °C -20°C~ 60°C
HDCS® Data Center Cabling Solution Products
38
Applications• •High capacity I/O in storage area networks• •Network attached storage, and storage servers• •Switched fabric I/O such as ultra high bandwidth switches and
routers• •Data center cabling infrastructure • Connectivity for storage, server and HPC
Product Features• 850nm VCSEL transmitter• Hot Pluggable, suitable for Industrial optional• 3.3V power supply voltage• All-metal housing for superior EMI performance• Operating case temperature: 0 to 70℃• RoHS, REACH compliant
Standards• SFP+: SFF-8431• SFP28: EDR InfiniBand• QSFP+: SFF-8436 • QSFP+: QDR/DDR/SDR InfiniBand • QSFP28: SFF-8665
FornaxTM Active Optical Cable
QSFP+/QSFP28 Active Optical Cable
100G QSFP28 to 4*25G SFP28 Active Optical Cable
SFP+/SFP28 Active Optical Cable
HDCS® Data Center Cabling Solution Products
39
PN Series Description
10G/40G Active Optical Cable
CPS2-261-XXXX AOC,10G SFP+ to SFP+, OM3 LSZH XXX.Xm
CPQ2-161-XXXX AOC, 40G QSFP to 4x 10G SFP+, OM3 LSZH XXX.Xm
CPQ2-361-XXXX AOC, 40G QSFP to 40G QSFP, OM3 LSZH XXX.Xm
25G/100G AOC Active Optical Cable
CPG2-461-XXXX AOC,25G SFP28 to SFP28, OM3 LSZH XXX.Xm
CPH2-561-XXXX AOC, 100G QSFP28 to 4x 25G SFP28, OM3 LSZH XXX.Xm
CPH2-661-XXXX AOC, 100G QSFP28 to 100G QSFP28, OM3 LSZH XXX.Xm
Remark: XXXX for cable length. 0050 represents 5metersPN example: CPH2-661-0050 100G QSFP28 AOC, OM3 LSZH 5meters
Product TypeSupport Distance(meter)
OM3 fiber OM4 fiber
10G SFP+ AOC 300 550
25G SFP28 AOC 70 100
40G QSFP+ AOC 100 150
100G QSFP28 AOC 70 100
Product Types
40
Applications• High capacity I/O in storage area networks• Network attached storage, and storage Servers• Switched fabric I/O such as ultra high bandwidth switches and
routers• Data center cabling infrastructure• High density connections between networking equipment
Features• Support for multi-gigabit data rates up 10G, 25G, 40G, 100G• Data rates backward compatible to 1Gbps• Hot-pluggable SFP 20PIN footprint• I/O Connector designed for high speed differential signal appli-
cations• Improved Pluggable Form Factor(IPF) compliant for enhanced
EMI/EMC performance
• Compatible to SFP+ MSA
Parameters• Bit error rate: < 10E-12• Hot-pluggable, industry-standard small form-factor• Pluggable(SFP+/SFP28) copper cable, ≤ 7m• Pluggable(QSFP/QSFP28) copper cable, ≤ 5m• Temperature range: 0°C ~ +70 °C• RoHS compliant
Standards• SFP+: SFF 8431• QSFP+: SFF 8436• QSFP+: QDR InfniBand• QSFP28: SFF-8665
FornaxTM SFP+/QSFP+ Direct Attach Passive Copper Cables
10G SFP+/25G SFP28Passive Copper Cable 100G QSFP28/40G QSFP to 4X25G/10GSplitter Copper Cable
FornaxTM SFP+/QSFP+DAC Ordering Information
Digit3 Digit4 Digit5 Digit6 Digit7 Digit8-11
CP S:SFP+ 1: Passive 1: 4xSFP+(40G) 1:30AWG 1: 0°C~70°C CableLengthXX.X meter
Q:QSFP+/QSFP28
2: Active 2: SFP+(10G) 2: 28AWG 2: -5°C~85°C
3:QSFP+(40G) 3: 26AWG 3: -40°C~85°C
4:QSFP28(100G) 4: 24AWG
5:SFP28(25G)
Rosenberger Direct Attach Passive Copper Cables(DAC) are ordered using 11 digits: Digit3, module type selection; Digit4, power supply; Digit5, splitter module selection; Digit6, copper selection; Digit7, operating case temperature; Digit8-11, length selection.Example: CPS1-241-030 10G DAC cable, SFP+-SFP+, 24AWG, 0-70℃, 3meters
HDCS® Data Center Cabling Solution Products
41
Open Type Hybrid Box Type Hybrid
TaurusTM I Hybrid patch Panel
• Built-in cable management; easy maintenance• All Rosenberger Keystone and fiber adapters can be installed
into modules• Patch panel can be both installed in standard 19” cabinet and
open cable tray
Parameters• Materials: steel• Size: 1HU height, 19” width • With accessory for fixing patch panel on open cable tray
Applications• Data Center EDA• Administration Room of Building Structure cabling system
Features• Hybrid type for both Fiber and Copper solution• Maximum three modules can be installed into one patch
panel, up to 72 cores with LC connector or 36 copper connec-tions; can intermix fiber and copper
• Support both trunk cable and fusion solution for fiber cable
Order InformationType Ordering Number Products Description
Open Type Hybrid
CPB1-310-21 1HU Open Type Hybrid Patch Panel (Empty)
CPB5-101-21 CAT5E Module (Incl. 12 CAT5E Keystone)
CPB5-102-21 CAT6 Module (Incl. 12 CAT6 Keystone)
CPB5-203-21 LC 24F 9/125 Module (with Adapter)
CPB5-204-21 LC 24F 50/125 Module (with Adapter)
CPB5-205-21 LC 24F Laser Optimize 50/125 Module (with Adapter)
CPB5-203-31 LC 12F 9/125 Module (with Adapter)
CPB5-204-31 LC 12F 50/125 Module (with Adapter)
CPB5-205-31 LC 12F Laser Optimize 50/125 Module (with Adapter)
CPB5-305-11 MPO 96F Module (with Adapter)
CPB5-404-41 Module Protective Box
Box Type Hybrid
CPB1-310-28 1HU Box Type Hybrid Patch Panel (Empty)
CPB5-108-11 UTP Module (Empty with 8 Ports)
CPB5-508-11 FTP Module (Empty with 8 Ports)
CPB5-233-21 LC 24F 9/125 Fusion Type Module (with Adapter)
CPB5-234-21 LC 24F 50/125 Fusion Type Module (with Adapter)
CPB5-235-21 LC 24F Laser Optimize 50/125 Fusion Type Module (with Adapter)
CPB5-233-31 LC 12F 9/125 Fusion Type Module (with Adapter)
CPB5-234-31 LC 12F 50/125 Fusion Type Module (with Adapter)
CPB5-235-31 LC 12F Laser Optimize 50/125 Fusion Type Module (with Adapter)
Splice Chip 997844003 Splice Chip (12 Slices)
HDCS® Data Center Cabling Solution Products
42
Technical Data• Plug insertion life: 750 cycles min.• Plug retention force: 30 Lbs min.• IDC contactor: accept 22-26 AWG solid wires• Storage temperature: -40°C ~ +70°C• Working temperature: -20°C ~ +60°C
Standards• ANSI/TIA568-D.2• ANSI/TIA568-D.3• ANSI/TIA 942-B • ISO/IEC11801• EN50173-5
Applications• TaurusTM II Modular 24 Ports FO-CU Hybrid Patch Panel is
generally used for connecting optical and copper LAN cable at each distribution area in data center room, such as EDA zone.
Features• The empty panel is capable of holding 24 modules• The module supports fiber and copper• Each port has a spring dust cover that is good for dust protection• The empty panel has separately label with every module in
front side• Labels come in various colors for easy identification• The module can been maintained in front
TaurusTM II Modular 24 Ports FO-CU Hybrid Patch Panel
TaurusTM II Modular 24 Ports FO-CU Hybrid Patch Panel Module Holder
Order Information
Ordering Number Products Description
CPB1-540-21 24P Modular FO-CU Hybrid Patch Panel (with Black Module Holder without Module)
CPB1-510-21 24P Modular FO-CU Hybrid Patch Panel (without Module Holder and Module)
CPB8-000-01 Module Holder for FO-CU Hybrid Patch Panel, Black
CPB8-000-02 Module Holder for FO-CU Hybrid Patch Panel, Yellow
CPB8-000-03 Module Holder for FO-CU Hybrid Patch Panel, Blue
CPB8-000-05 Module Holder for FO-CU Hybrid Patch Panel, Red
CPB8-000-06 Module Holder for FO-CU Hybrid Patch Panel, Green
CP33-364-01 LC Duplex MM Module, Beige
CP33-36H-01 LC Duplex OM3/OM4 MM Module, Aqua
CP33-368-01 LC Duplex SM Module, Blue
CP31-13C-11 CAT6 UTP 90 Degree Tool-less Module, Black
CP31-171-21 CAT6 UTP Keystone, Black, 180°
HDCS® Data Center Cabling Solution Products
43
copper cable available• Each copper permanent link performance far exceeds standard
TIA568-D and ISO11801 especially for short link performance
Parameters• Storage temperature: -40°C ~ +70°C• Operation temperature: -20°C ~ +60°C
Standards• ANSI/TIA- 568-D• TIA-942-B• ISO/IEC11801• EN50173-5
Applications• PegasusTM PreCONNECT Copper cable can be used to quickly
deploy a permanent link between the distribution area to equip-ment area in a data center.
Features• Quick and easy installation, saving on-site labor costs• Guarantee high reliability base on 100% quality inspection in
factory• CAT6 , CAT6A and Unshielded , shielded various of type for op-
tion• CM, CMR, CMP and LSZH series Fire retardant Pre-connect
PegasusTM Pre-connect Copper Cable
Pre-connect Copper Cable Pre-connect Copper Cable
Order Information
Ordering Number Products Description
CPB6-121-3-XXX PegasusTM 6Port CAT6 UTP Fan-Out Preconnect Copper Cable, CM
CPB6-123-3-XXX PegasusTM 6Port CAT6 UTP Fan-Out Preconnect Copper Cable, LSZH
CPB6-221-3-XXX PegasusTM 6Port CAT6 FTP Fan-Out Preconnect Copper Cable, CM
CPB6-223-3-XXX PegasusTM 6Port CAT6 FTP Fan-Out Preconnect Copper Cable, LSZH
CPB6-131-3-XXX PegasusTM 6Port CAT6AUTP Fan-Out Preconnect Copper Cable, CM
CPB6-133-3-XXX PegasusTM 6Port CAT6A UTP Fan-Out Preconnect Copper Cable, LSZH
CPB6-231-3-XXX PegasusTM 6Port CAT6A FTP Fan-Out Preconnect Copper Cable, CM
CPB6-233-3-XXX PegasusTM 6Port CAT6A FTP Fan-Out Preconnect Copper Cable, LSZH
Remark: XXX represent length, as 5 meters: “005”
HDCS® Data Center Cabling Solution Products
44
Technical Parameters• Plug insertion life: 750 cycles min• Plug retention force: 30 Lbs Min• IDC contactor: accept 22-26 AWG solid wires• Temperature range: -40°C ~ +70°C
Standards• ANSI/TIA568-D.2• ANSI/TIA 942-B • ISO/IEC11801• EN50173-5
Applications• ApusTM high density modular panel is generally used to con-
nect copper LAN cable at each distribution area in data center room, such as EDA, MDA and SAN zone.
Features• 48 ports is available in 1HU• Meets multiple requirements with double label system • Distinct markers for rotating label and protection cover • Easy cable management • Controlling cable bending radius from cabling managements of
panel • Diversiform patch cords and modules optional
ApusTM 48 Ports Patch Panel
ApusTM 48 Ports Unshielded Patch Panel ApusTM 48port Shielded Panel
Transmission Parameter (for Connecting Hardware, at 20°C)Frequency (MHz) Attenuation (dB/100m) NEXT (dB) RL (dB) PSNEXT (dB) ACRF (dB) PSACRF (dB)
Max. Min. Min. Min. Min. Min.
1.0 0.1 75.0 30.0 73.0 83.1 80.1
4.0 0.1 75.0 30.0 72.3 71.1 68.1
8.0 0.1 75.0 30.0 71.0 661 65.4
10.0 0.1 74.0 30.0 70.0 63.1 60.1
16.0 0.1 69.9 30.0 65.9 59.0 56.0
20.0 0.1 68.0 30.0 64.0 57.1 54.1
25.0 0.1 66.0 30.0 62.2 53.2 52.6
31.25 0.11 64.1 30.0 60.1 50.0 50.2
62.5 0.16 58.1 28.1 54.1 47.2 44.2
100.0 0.20 54.0 24.0 50.0 43.1 40.1
200.0 0.28 48.0 18.0 44.0 37.1 34.1
250.0 0.32 46.0 16.0 42.0 35.1 32.1
HDCS® Data Center Cabling Solution Products
45
ApusTM 48 Ports Patch Panel
Order Information
Ordering Number Products Description
CP41-431-08-E CAT6 1HU 48 Ports UTP Copper Panel, without Keystone
CP31-131-21 CAT6 UTP Keystone, Black, 180°
CP31-131-22 CAT6 UTP Keystone, Yellow, 180°
CP31-131-23 CAT6 UTP Keystone, blue, 180°
CP31-131-24 CAT6 UTP Keystone, Ivory, 180°
CP31-131-25 CAT6 UTP Keystone, Red, 180°
CP41-431-08 CAT6 1HU 48 Ports UTP Copper Panel, W/BK Keystone
CP41-431-08L CAT6 1U 48port UTP Modular panel W/Front Mgmt and BK Keystone
CP41-451-08-E CAT6A 1HU 48 Ports UTP Copper Panel, without Keystone
CP31-171-21 CAT6 UTP Keystone, Black, 180°
CP31-171-22 CAT6A UTP Keystone, Yellow, 180°
CP31-171-23 CAT6A UTP Keystone, blue, 180°
CP31-171-24 CAT6A UTP Keystone, Ivory, 180°
CP31-171-25 CAT6A UTP Keystone, Red, 180°
CP41-451-08 CAT6A 1HU 48 Ports UTP Copper Panel, W/BK Keystone
CP41-451-08L CAT6A 1U 48port UTP Modular Panel W/Front Mgmt and BK Keystone
CP41-451-08-E CAT6A 1HU 48 Ports UTP Copper Panel, without Keystone
CP41-331-08 CAT6 1HU 48 Ports FTP Copper Panel, W/BK Keystone
CP41-331-08E CAT6 1HU 48 Ports FTP Copper Panel, without Keystone
CP41-331-08L CAT6 1HU 48 Ports FTP Copper Panel, W/Front Mgmt and Keystone
CP31-532-14 CAT6 FTP Zinc Alloy Keystone, Tool-less, 90°
CP41-351-08 CAT6A 1HU 48 Ports FTP Copper Panel, with Keystone
CP41-351-08E CAT6A 1HU 48 Ports FTP Copper Panel, without Keystone
CP41-351-08L CAT6A 1HU 48 Ports FTP Copper Panel,W/Front Mgmt and BK Keystone
CP31-572-14 CAT6A FTP Zinc Alloy Keystone, Tool-less, 90°
CP91-100-00 Keystone Dummy Plug for Modular Panel or Faceplate, Black
CP91-200-00 Keystone Dummy Plug for Modular Panel or Faceplate, White
* Note: more detail information, please contact with Rosenberger sales
46
• Panel with longer rear cable for easy cable management and cable bending radius
• The keystone jack in panel could support excellent short link per-formance
• Tool-less termination based on innovative hinged pressing cover.• Diversiform patch cords and modules optional
Technical Parameters• Plug insertion life: 750 cycles min.• Plug retention force: 30 Lbs min.• IDC contactor: Accept 22-26 AWG solid wires
• Temperature range: -40°C ~ +70°C
Standards• ANSI/TIA568-D.2• ANSI/TIA568-D.3• ANSI/TIA 942-B • ISO/IEC11801• EN50173-5
ApplicationsApusTM CAT6 data cable for structured premise cabling transmits voice, data and video signals. It supports current high-bandwidth applications, especially suitable for application of Fast-Ethernet. Used in connecting copper LAN cable at each distribution area in data center room.• VoIP • ISDN • Token ring• 100 Mbps TP-PMD• Analog and digital video• TR-16 Active and Passive• 155 Mbit /622Mbit /1.2 Gbit ATM• 10baseT/100baseTX Fast /1000baseTX Gigabit Ethernet
Features• Each port has a spring dust cover• Four sets of color labels provided for cable identification and man-
agement
ApusTM CAT6 UTP Copper Cabling System
Transmission Parameter (for Permanent Link, at 20°C)Frequency (MHz) Attenuation (dB/100m) NEXT (dB) RL (dB) PSNEXT (dB) ACRF (dB) PSACRF (dB)
Max. Min. Min. Min. Min. Min.
1.0 1.9 65.0 19.1 62.0 64.2 61.2
4.0 3.5 64.1 21.0 61.8 52.1 49.1
8.0 5.0 59.4 21.0 57.0 46.1 43.1
10.0 5.5 57.8 21.0 55.5 44.2 41.2
16.0 7.0 54.6 20.0 52.2 40.1 37.1
20.0 7.9 53.1 19.5 50.7 38.2 35.2
HDCS® Data Center Cabling Solution Products
47
ApusTM CAT6 UTP Copper Cabling System
Transmission Parameter (for Permanent Link, at 20°C)Frequency (MHz) Attenuation (dB/100m) NEXT (dB) RL (dB) PSNEXT (dB) ACRF (dB) PSACRF (dB)
Max. Min. Min. Min. Min. Min.
25.0 8.9 51.5 19.0 49.1 36.2 33.2
31.25 10.0 50.0 18.5 47.5 34.3 31.3
62.5 14.4 45.1 16.0 42.7 28.3 25.3
100.0 18.6 41.8 14.0 39.3 24.2 21.2
200.0 27.4 36.9 11.0 34.3 18.2 15.2
250.0 31.1 35.3 10.0 32.7 16.2 13.2
Order Information
Ordering Number Products Description
CP11-141-12 ApusTM CAT6 UTP 4-pair CM LAN Cable, 305m
CP11-141-13 ApusTM CAT6 UTP 4-pair LSZH LAN Cable, 305m
CP11-141-14 ApusTM CAT6 UTP 4-pair CMR LAN Cable, 305m
CP11-141-16 ApusTM CAT6 UTP 4-pair CMP LAN Cable, 305m
CP31-131-21 ApusTM CAT6 UTP Keystone, Black, 180°
CP31-131-24 ApusTM CAT6 UTP Keystone, Ivory, 180°
CP31-13C-11 ApusTM CAT6 UTP 90 Degree Tool-less Module, Black
CP31-13C-14 ApusTM CAT6 UTP 90 Degree Tool-less Module, Ivory
CP41-431-03N-E ApusTM CAT6 UTP Modular Cap Patch Panel, 24-port (without Keystone)
CP41-431-03N ApusTM CAT6 UTP Modular Cap Patch Panel, 24-port (with Standard Keystone)
CP41-431-03N-P ApusTM CAT6 UTP Modular Cap Patch Panel, 24-port (with Tool-less Keystone)
CP41-431-13-E ApusTM CAT6 UTP “W” Style Patch Panel, 24-port (without Keystone)
CP41-431-13 ApusTM CAT6 UTP “W” Style Patch Panel, 24-port (with Standard Keystone)
CP41-431-13-P ApusTM CAT6 UTP “W” Style Patch Panel, 24-port (with Tool-less Keystone)
CP61-421-12 ApusTM CAT6 RJ45-RJ45 UTP 4-pair Patch Cord CM, 2m, Grey
CP61-421-22 ApusTM CAT6 RJ45-RJ45 UTP 4-pair Patch Cord LSZH, 2m, Grey
CP61-421-72 ApusTM Safety Lock CAT6 RJ45-RJ45 UTP 4-pair Patch Cord CM, 2m, Grey
CP61-421-82 ApusTM Safety Lock CAT6 RJ45-RJ45 UTP 4-pair Patch Cord LSZH, 2m, Grey
CP42-231-01 Data Center 1HU Metal Wire Management, Deep Type
CP91-100-00 Keystone Dummy Plug for Modular Panel or Faceplate, Black
CP91-200-00 Keystone Dummy Plug for Modular Panel or Faceplate, White
*Note: more detail information, such as color, length etc., please contact with Rosenberger sales
48
ApplicationsApusTM CAT6 data cable for structured premise cabling transmits voice, data and video signals. It supports current high-bandwidth applications, especially suitable for application of Fast-Ethernet. Used to connect copper LAN cable at each distribution area in data center room.• VoIP• ISDN • Token Ring• 100 Mbps TP-PMD• Analog and Digital Video• TR-16 Active and Passive• 155 Mbit /622Mbit /1.2 Gbit ATM• 10baseT/100baseTX Fast /1000baseTX Gigabit Ethernet
Features• Each port has a spring dust cover• Four sets of color labels provided for cable identification and man-
agement
ApusTM CAT6 FTP Copper Cabling System
• Panel with longer rear cable for easy cable management and cable bending radius control
• Keystone jack in panel could support excellent short link perfor-mance
• Tool-less termination based on innovative hinged pressing cover• Diversiform patch cords and modules optional
Technical Parameters• Plug insertion life: 750 cycles min.• Plug retention force: 30 Lbs min.• IDC contactor: accept 22-26 AWG solid wires• Temperature range: -40°C ~ +70°C
Standards• ANSI/TIA568-D.2• ANSI/TIA 942-B • ISO/IEC11801• EN50173-5
HDCS® Data Center Cabling Solution Products
49
ApusTM CAT6 FTP Copper Cabling System
Transmission Parameter (for Permanent Link, at 20°C)Frequency (MHz) Attenuation (dB/100m) NEXT (dB) RL (dB) PSNEXT (dB) ACRF (dB) PSACRF (dB)
Max. Min. Min. Min. Min. Min.
1.0 1.9 65.0 19.1 62.0 64.2 61.2
4.0 3.5 64.1 21.0 61.8 52.1 49.1
8.0 5.0 59.4 21.0 57.0 46.1 43.1
10.0 5.5 57.8 21.0 55.5 44.2 41.2
16.0 7.0 54.6 20.0 52.2 40.1 37.1
20.0 7.9 53.1 19.5 50.7 38.2 35.2
25.0 8.9 51.5 19.0 49.1 36.2 33.2
31.25 10.0 50.0 18.5 47.5 34.3 31.3
62.5 14.4 45.1 16.0 42.7 28.3 25.3
100.0 18.6 41.8 14.0 39.3 24.2 21.2
200.0 27.4 36.9 11.0 34.3 18.2 15.2
250.0 31.1 35.3 10.0 32.7 16.2 13.2
Order Information
Ordering Number Products Description
CP11-241-12 ApusTM CAT6 FTP 4-pair CM LAN Cable, 305m
CP11-241-13 ApusTM CAT6 FTP 4-pair LSZH LAN Cable, 305m
CP11-241-14 ApusTM CAT6 FTP 4-pair CMR LAN Cable, 305m
CP11-241-16 ApusTM CAT6 FTP 4-pair CMP LAN Cable, 305m
CP31-231-24 ApusTM CAT6 FTP Keystone, Ivory, 180°
CP31-532-24 ApusTM CAT6 FTP Zinc Alloy Tool-less, Ivory, 180°
CP41-331-03N-E ApusTM CAT6 FTP Modular Cap Patch Panel, 24-port (without Keystone)
CP41-331-03N ApusTM CAT6 FTP Modular Cap Patch Panel, 24-port (with Standard Keystone)
CP41-331-13-E ApusTM CAT6 FTP “W” Style Patch Panel, 24-port (without Keystone)
CP41-331-13 ApusTM CAT6 FTP “W” Style Patch Panel, 24-port (with Standard Keystone)
CP64-421-12 ApusTM CAT6 RJ45-RJ45 FTP 4-pair Patch Cord CM, 2m, Grey
CP64-421-22 ApusTM CAT6 RJ45-RJ45 FTP 4-pair Patch Cord LSZH, 2m, Grey
CP64-421-72 ApusTM Safety Lock CAT6 RJ45-RJ45 FTP 4-pair Patch Cord CM, 2m, Grey
CP64-421-82 ApusTM Safety Lock CAT6 RJ45-RJ45 FTP 4-pair Patch Cord LSZH, 2m, Grey
CP42-231-01 Data Center 1HU Metal Wire Management, Deep Type
CP91-100-00 Keystone Dummy Plug for Modular Panel or Faceplate, Black
CP91-200-00 Keystone Dummy Plug for Modular Panel or Faceplate, White
*Note: more detail information, such as color, length etc., please contact with Rosenberger sales
50
DracoTM CAT6A UTP Copper Cabling System
Technical Parameters• Plug insertion life: 750 cycles min.• Plug retention force: 30 Lbs min.• IDC contactor: accept 22-26 AWG solid wires• Temperature range: -40°C ~ +70°C
Standards• ANSI/TIA568-D.2• ANSI/TIA 942-B • ISO/IEC11801• EN50173-5
ApplicationsHDCS® DracoTM CAT6A data cable for structured premise cabling transmits voice, data and video signals. It supports current and future high-bandwidth applications, especially suitable for appli-cation of Class EA. Used in connecting copper LAN cable at each distribution area in data center room.• VoIP • ISDN • Token Ring• 100 Mbps TP-PMD• Analog and Digital Video• TR-16 Active and Passive• 155 Mbps /622Mbit /1.2 Gbps ATM• 10BaseT/100BaseTX Fast /1000BaseTX Gigabit
Ethernet/10GBase-T Ethernet
Features• Flexible and modular • Diversiform patch cords and modules optional• Labels provided for cable identification and management• Panel with longer rear cable for easy cable management and
controlling cable bending radius• Excellent short link performance based on unique design
HDCS® Data Center Cabling Solution Products
51
DracoTM CAT6A UTP Copper Cabling System
Transmission Parameter (for Permanent Link, at 20°C)
Frequency (MHz) Attenuation (dB/100m) NEXT (dB) RL (dB) PSNEXT (dB) ACRF (dB) PSACRF (dB) PSANEXT (dB)
Max. Min. Min. Min. Min. Min. Min.
1.0 1.9 65.0 19.1 62.0 64.2 62.0 67.0
4.0 3.5 64.1 21.0 61.8 52.1 61.8 67.0
8.0 5.0 59.4 21.0 57.0 46.1 57.0 67.0
10.0 5.5 57.8 21.0 55.5 44.2 55.5 67.0
16.0 7.0 54.6 20.0 52.2 40.1 52.2 67.0
20.0 7.8 53.1 19.5 50.7 38.2 50.7 67.0
25.0 8.8 51.5 19.0 49.1 36.2 49.1 66.0
31.25 9.8 50.0 18.5 47.5 34.3 47.5 65.1
62.5 14.0 45.1 16.0 42.7 28.3 42.7 62.0
100.0 18.0 41.8 14.0 39.3 24.2 39.3 60.0
200.0 26.1 36.9 11.0 34.3 18.2 34.3 55.5
250.0 29.5 35.3 10.0 32.7 16.2 32.7 54.0
300.0 32.7 34.0 9.2 31.4 14.6 31.4 52.8
400.0 38.4 29.9 8.0 27.1 12.1 27.1 51.0
500.0 43.8 26.7 8.0 23.8 10.2 23.8 49.5
Order Information
Ordering Number Products Description
CP11-171-12 DracoTM CAT6A UTP 4-pair CM LAN Cable, 305m
CP11-171-13 DracoTM CAT6A UTP 4-pair LSZH LAN Cable, 305m
CP11-171-14 DracoTM CAT6A UTP 4-pair CMR LAN Cable, 305m
CP11-171-16 DracoTM CAT6A UTP 4-pair CMP LAN Cable, 305m
CP31-171-24 DracoTM CAT6A UTP Keystone, Ivory
CP41-451-03-E DracoTM CAT6A UTP Modular Patch Panel, 24-port (without Keystone)
CP41-451-03 DracoTM CAT6A UTP Modular Patch Panel, 24-port (with Standard Keystone)
CP61-431-12 DracoTM CAT6A RJ45-RJ45 UTP 4-pair Patch Cord CM, 2m, Grey
CP61-431-22 DracoTM CAT6A RJ45-RJ45 UTP 4-pair Patch Cord LSZH, 2m, Grey
CP61-431-72 DracoTM Safety Lock CAT6A RJ45-RJ45 UTP 4-pair Patch Cord CM, 2m, Grey
CP61-431-82 DracoTM Safety Lock CAT6A RJ45-RJ45 UTP 4-pair Patch Cord LSZH, 2m, Grey
CP42-231-01 Data Center 1HU Metal Wire Management, Deep Type
CP91-100-00 Keystone Dummy Plug for Modular Panel or Faceplate, Black
CP91-200-00 Keystone Dummy Plug for Modular Panel or Faceplate, White
*Note: more detail information, such as color, length etc., please contact with Rosenberger sales
52
DracoTM CAT6A FTP Copper Cabling System
• Panel with longer rear cable for easy cable management and cable bending radius control
• Keystone jack in panel supports excellent short link performance.• Tool-less termination based on innovative hinged pressing cover• Diversiform patch cords and modules optional
Technical Parameters• Plug insertion life: 750 cycles min.• Plug retention force: 30 Lbs min.• IDC contactor: accept 22-26 AWG solid wires• Temperature range: -40°C ~ +70°C
Standards• ANSI/TIA568-D.2• ANSI/TIA 942-B • ISO/IEC11801• EN50173-5
ApplicationsHDCS® DracoTM CAT6A data cable for structured premise cabling transmits voice, data and video signals. It supports current and future high-bandwidth applications, especially suitable for appli-cation of Class EA. Used to connect copper LAN cable at each distribution area in data center room.• VoIP • ISDN • Token Ring• 100 Mbps TP-PMD• Analog and Digital Video• TR-16 Active and Passive• 155 Mbps /622Mbit /1.2 Gbps ATM• 1 0 B a s e T / 1 0 0 B a s e T X F a s t / 1 0 0 0 B a s e T X G i g a b i t
Ethernet/10GBase-T Ethernet
Features• Each port has a spring dust cover• Four sets of color labels provided for cable identification and man-
agement
HDCS® Data Center Cabling Solution Products
53
DracoTM CAT6A FTP Copper Cabling System
Transmission Parameter (for Permanent Link, at 20°C)Frequency (MHz) Attenuation (dB/100m) NEXT (dB) RL (dB) PSNEXT (dB) ACRF (dB) PSACRF (dB) PSANEXT (dB)
Max. Min. Min. Min. Min. Min. Min.
1.0 1.9 65.0 19.1 62.0 64.2 62.0 67.0
4.0 3.5 64.1 21.0 61.8 52.1 61.8 67.0
8.0 5.0 59.4 21.0 57.0 46.1 57.0 67.0
10.0 5.5 57.8 21.0 55.5 44.2 55.5 67.0
16.0 7.0 54.6 20.0 52.2 40.1 52.2 67.0
20.0 7.8 53.1 19.5 50.7 38.2 50.7 67.0
25.0 8.8 51.5 19.0 49.1 36.2 49.1 66.0
31.25 9.8 50.0 18.5 47.5 34.3 47.5 65.1
62.5 14.0 45.1 16.0 42.7 28.3 42.7 62.0
100.0 18.0 41.8 14.0 39.3 24.2 39.3 60.0
200.0 26.1 36.9 11.0 34.3 18.2 34.3 55.5
250.0 29.5 35.3 10.0 32.7 16.2 32.7 54.0
300.0 32.7 34.0 9.2 31.4 14.6 31.4 52.8
400.0 38.4 29.9 8.0 27.1 12.1 27.1 51.0
500.0 43.8 26.7 8.0 23.8 10.2 23.8 49.5
Order InformationOrdering Number Products Description
CP11-271-12 DracoTM CAT6A FTP 4-pair CM LAN Cable, 305m
CP11-271-13 DracoTM CAT6A FTP 4-pair LSZH LAN Cable, 305m
CP11-271-14 DracoTM CAT6A FTP 4-pair CMR LAN Cable, 305m
CP11-271-16 DracoTM CAT6A FTP 4-pair CMP LAN Cable, 305m
CP31-572-24 DracoTM CAT6A FTP Zinc Alloy Tool-less, Ivory, 180°
CP41-351-03N-E DracoTM CAT6A FTP Modular Cap Patch Panel, 24-port (without Keystone)
CP41-351-03N DracoTM CAT6A FTP Modular Cap Patch Panel, 24-port (with Zinc Alloy Keystone)
CP41-351-13-E DracoTM CAT6A FTP “W” Style Patch Panel, 24-port (without Keystone)
CP41-331-13 DracoTM CAT6A FTP “W” Style Patch Panel, 24-port (with Zinc Alloy Keystone)
CP64-431-12 DracoTM CAT6A RJ45-RJ45 FTP 4-pair Patch Cord CM, 2m, Grey
CP64-431-22 DracoTM CAT6A RJ45-RJ45 FTP 4-pair Patch Cord LSZH, 2m, Grey
CP64-431-72 DracoTM Safety Lock CAT6A RJ45-RJ45 FTP 4-pair Patch Cord CM, 2m, Grey
CP64-431-82 DracoTM Safety Lock CAT6A RJ45-RJ45 FTP 4-pair Patch Cord LSZH, 2m, Grey
CP42-231-01 Data Center 1HU Metal Wire Management, Deep Type
CP91-100-00 Keystone Dummy Plug for Modular Panel or Faceplate, Black
CP91-200-00 Keystone Dummy Plug for Modular Panel or Faceplate, White
*Note: more detail information, such as color, length etc., please contact with Rosenberger sales
55
HSBC London
Citigroup, London
Royal Bank of Scotland
BNP Paribas, Paris
United Bank of Switzerland
Lloyds TSB Group
Bank of Netherlands, Amsterdam
Deutsche Bank, Frankfurt
Deutsche Bundesbank
TUV Rheinland Group
Commerzbank
Fortis Bank, Belgium
Crédit Mutuel
AXA Insurance, Paris
Frankfurt Airport
UniCredit SpA
ISP Investment Company
Allianz Group
German\France IBM SO Datacenter
Lehman Brother Inc.
T-System
BMW
E.ON German
Mercedes-Benz
Baidu Data Center in Japan
Baidu Data Center in America
Tencent Data Center in Toronto Canada
Tencent Data Center in Barrie, Canada
Tencent Data Center in New Jersey, USA
Evoswitch Data Center in Netherlands
Akquinet Data Center in German
Equinix Data Center in German
Air France Cata Center in French
Generali Data Center in Italy
IBM SO Data Center in Italy
The City Bank in Dhaka, Bangladesh
Grameenphone New Storage Data Centerin Dhaka, Bangladesh
Edison Group in Dhaka, Bangladesh
Maybank (formerly BII)in Jakatar, Indonesia
Brazil Level 3 (Global Crossing) Data center
Brazil Bradesco Bank
Major Projects at a Glance
56
Major Projects at a Glance
Brazil Brazilian Bank
Brazil Itau Bank
Brazil Oi-Telemar
Brazil Embratel
China Construction Bank
China Construction Bank, Guangdong
China Construction Bank, Yunnan
The People’s Bank of China, Harbin
Industrial and Commercial Bank of Guangzhou
Industrial and Commercial Bank of Chengde
Bank of Communications
Bank of Beijing
Huaxia Bank
Changsha Commercial Bank Disaster Recovery Center
PICC
China Pacific Insurance (Group) Co., Ltd
Taiping Life Insurance Co., Ltd
Union Life Insurance Co., Ltd
Jiahe Life Insurance Co., Ltd
Dongwu Stock Jobber
Yan’an Rural Credit Cooperatives
Sina
Baidu
Soho
Tencent
Ifeng
Patrol China Beijing
Iqiyi
North China Oil Field
State Grid Corporation of China
Guangzhou 2010 Asian Games
Beijing Municipal Government
Guangzhou Municipal Government
Shanghai Pudong Zhangjiang
Shanghai Volkswagen
The Bureau of Land Resources Nanjing
China Science and Technology Museum
Zhejiang Local Taxation
Dr. Peng Beijing
Nanjing University
57
Major Projects at a Glance
Shanghai Institute of Technology
Beijing Telecom
Shanghai Northeast Logistics Park
Guiyang Tobacco
NTT Tianjing
China Mobile DataCenter in Shanghai
Ele.me Data center,China
National Internet Center,China
Suning Ecommerce Data Center,China
JD.com Data center,China
China Ministry of Industry and Information Technology Data Center
Iqiyi Data Center,China
Shenzhen Baode Data Center,China
MI Data Center,China
Sina Data Center,China
Meituan Data Center,China
DiDi Data Center,China
Beijing Bio Corporation Data Center,China
TravelSky Data Center,China
State Grid Disaster Recovery Data Center,China
Ministry of Land and Resources in Beijing ,China
Anbang Insurance Group Data Center,China
Jinan Yaoqiang International Airport Data Center,China
Education Department Data Center in Shandong,China
Supercomputer Center in Shandong,China
Maritime Bureau Data Center in QinDao,China
Taxation Bureau Data Center in Jinan City,China
Submarine Academy in Qindao,China
National Security Bureau Data Center,China
The General Administration of Customs Data Center,China
New Airport Data Center in Qindao,China
China Institute of Oceanography.