with our digismart control board ptac catalog€¦ · control board standard features. ct-dptac 3...
TRANSCRIPT
CT-DPTAC www.amana-ptac.com 10/12Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Supersedes 6/12
Packaged Terminal air condiTioners and HeaT PumPs
wiTH our digismarT® conTrol Board & ems
PTac caTalog
• First-YearWarranty:Parts&Labor• SecondthroughFifthYear:Parts&Laboroncertainsealed
systemcomponents
• SecondthroughFifthYear:oncertainfunctionalpartsonly* Completewarrantydetailsavailablefromyourlocaldealeror
atwww.amana-ptac.com.
2 www.amana-ptac.com CT-DPTAC
• EnergyEfficiencies:WithEERsupto11.7andCOPsupto3.4,ourunit’shighefficienciesmayqualifyyouformanyoftherebatesofferedbyelectricalpowercompanies.
• QuietOperation:OurPTAChasbeenredesignedtobethequietestPTACwe’veeverbuilt.Theunit’sstate-of-the-artdesignandconstructionprovideaquietenvironment,allowinggueststoenjoypeaceful,sleep-fillednights.• Twofanmotors(indoor/outdoor)• Indoortangentialfanforquietoperation• STCof28
• Assembled in the USA for 30 years: assembled at our plant in Fayetteville, TN, using Goodman resources includingengineering,production,andtesting.
• Increased Dehumidification Capacity:Maintain lower humidity levels in roomswhile cooling themwithout the needforexpensiveadd-ons.Asaresult,guestsfeelmorecomfortableathighertemperatures,thusreducingcoolingcosts.
• Seven-ButtonTouchPad:Providescompletecontroltoguestsforin-roomcomfortwhilemaintainingenergyefficiency.• Five-YearLimitedWarranty:Enjoyoneofthemostcomprehensivewarrantiesintheindustry:FirstYear:parts&labor;
secondthroughfifthyears:parts&laboroncertainsealedsystemcomponents;secondthroughfifthyears: oncertainfunctionalpartsonly.Forcompletewarrantydetails,visitwww.amana-ptac.com.
• 100%Run-Tested:Allunitsare100%runtestedatourplantinFayetteville,TN,includingleakchecksduringmanufacturingandagainpriortoshipmentatthewarehouse.
• 7⅝”UnitFrontDepth:Enhancevaluableroomspacewithourslimunitfront,whichhasasleek7⅝”depth,oneoftheshallowestsilhouettesintheindustrytoday.Inaddition,toinhibitguest-tampering,thefrontcanbesecuredtothechassiswithahiddenscrew.
• RemovableCondenserShroud:Allowseasyaccesstoenableregularcleaningofcoils,whichisessentialtomaintainunitefficiencyandprotectthecompressorforlongunitlife.
• EasyPull-OutFilters:Ourfiltersarewashableandeasytomaintain.• FilterDrierforSealedSystemRefrigerant:Standardinallunitstoprotectthecompressorandlengthenthelifeoftheunit
byremovingmoistureandpreventingacidformation.
Removable/CleanableShroudforeasycleaning
FilterDrier
EasyPull-upFilters
ControlBoard
sTandard FeaTures
CT-DPTAC www.amana-ptac.com 3
sTandard FeaTures (conT.)• CondensateDispersionSystem:Ourcondensatedispersionsystemremovescondensatefromindoorcoolingoperation
bythrowingwaterdirectlyontotheoutdoorcoilforrapidevaporationandincreasedcoolingefficiencies.Theslingerringonthenew,enhancedfandrawswaterupandintothefanblades.Thiswateristhenatomizedandevaporatedintotheatmospherethroughthecondenser.Increasedsurfaceareafromthecoilallowsmorewatertobeevaporatedonthesidesofthecoilsandhelpstominimizecondensaterun-off.
• FrontDeskControl:EachunitcomesequippedwiththeDigiSmart™controlandenergymanagementsoftware.WithDigi-Smart™usingtheoptionalRFAntennae,allunitscanbewirelesslyconnectedtoacentralhubforenhancedenergysavingsanddiagnostics.AmanabrandPTACsalsohavealow-voltageinterfacecapabilitywithafield-suppliedfront-deskON/OFFswitch.(SeePage4.)
• RoomFreezeProtection:Whentheunitsensestemperaturesof40°Forbelow,theunitactivatesthefanmotorandeithertheelectricresistanceheaterorthehydronicheater.
• Easy-to-useControls:Nocomplexcontrolstoconfuseyourguestsandcreatephonecallsforyourmanager.Controlsareeasytoread,understand,andactivate.Ournew7-buttoncontrolpanelprovidesguestswithcompletecontroloftheunitfortheirin-roomcomfortwhilemaintainingoverallenergyefficiency.
• EasytoServicewithOn-BoardLEDDiagnostics:Themaincomponentsareeasilyservicedandthereisnoguessingtode-terminetheproblemwithoureasy-to-readdiagnostics.
• StonewoodRoomFront:OurStonewoodroomfrontstrikesthebalancebetweenattractivestylingandpracticaldesign.Distinctivecontoursandamodernappearanceenhancethecharacterofeventhemostluxuriousroom,whilethesleek7⅝”depthmaximizesusablespaceforyourguests.
• RemoteThermostatControl:WhentheDigiSmart™wirelessremotethermostat(DS01E,soldseparately)issetup,boththeremotethermostatandunitcontrolpanelcontinuetocontroltheunit,providingflexibilityandhome-likesystemcontrol.Installationrequiresnomorethanpressingtwobuttons.Noneedtorunwiresormakeelectricalconnections.
• RemoteTemperatureSensing:Guestsenjoyultimatecomfortwithconsistentclimatecontrol.When thefield-installedthermistor(RTS03) isused,theunit-mountedthermostat isoverriddentoallowmoreaccurate, internalwall-sensingofroomambienttemperature.
• ExtendedHeatPumpHeating:Heatpumpmodelswilloperateintheheatingmodedowntoaslowas24°Foutdoorambi-enttemperature.
• ZeroFloorClearance:Theunitcanbeinstalledflushtoafinishedfloor,ifdesired.(Someaccessoriesdonothavezeroclear-ance).
• 30-SecondFan-OffDelay:Thefancontinuestorun30secondsafterthecompressorhasstoppedineithercoolingorheatpumpmodeandafterelectricheathasbeenturnedoff.Thisimprovesefficiencybydispersingtheconditionedaironthecoilsintotheroom.
• CompressorLock-In:Thisfeaturehelpsprolongthelifeofthecompressorbypreventingshort-cycling.Whenthecompres-sorisswitchedfromOfftoOnbecauseroomtemperaturehasrisenorfallenbelowthespecifiedlimit,itwillremainonforatleast4minutes.Ifthetemperatureset-pointischangedduringthis4minutes,thelock-infeatureisoverridden.
• AutomaticEmergencyHeat:Nomore“myunitisnotheating”complaintsduringthemiddleofthenight.Heatpumpunitswillautomaticallyswitchovertoelectricresistanceheatiftheheatpumpcompressorsystemfailsoriftheheatingloadisgreaterthantheunitcapacity.
• ConstantFanMode:Takeadvantageofeachunit’sdualoptions—selectcontinuousfanoperationorcyclethefanONandOFFwiththethermostat.Ournew7-buttondesignallowsgueststoselectfanperformancewhileallowingtheownertohavetheunitreverttothedesiredprogramofcontinuousfanorcyclewithconditioning.
• HiddenVentilationControl:Theventilationcontrolleverishiddenfromtheoccupant'sviewtoallowyoutomanageven-tilationrequirements.
• High-PressureSwitch:Protectstheunitfromhighpressureanddamagetotheunit,helpingtoensurelongunitlife.
4 www.amana-ptac.com CT-DPTAC
bringstogetherourbestPTACeverwithourbestEnergyManagementSoftwareandnowintegrationwithPropertyManagementandFrontDeskManagementSoftware.ReducePTACenergyconsumptionby35%ORMORE*throughthepowerofthein-unitEnergyManagementSystem,programmabletemperatureset-backandlimitscombined.ReducePTACmaintenancecostthroughourautomatedmaintenancenotificationsystem.Improvedmaintenancesustainsenergyefficiency(EER)andprolongsPTAClife,keepingequipmentrunningatitsdesignedefficiencylevelandroomguestsmorecomfortable.
THe amana Brand digismarT soluTion
in-room: “selF-insTallaBle” wireless PeriPHerals
TheDigiSmartOccupancy Sensor completes the in-roomequipment. This infraredsensorcandetermineiftheroomisoccupiedorempty,andwhenemptysignalsthePTACtoadjustthetemperaturetosaveenergybasedonprogrammablesetbacks.
The DigiSmart Wireless Remote Thermostat can mount on the wall anywhere intheguestroom.BatterypoweredandwithitsownwirelessabilitytocommunicatewiththePTACtomaintainroomtemperature.Bestofall,nowirestorun.ThePTACandThermostatconnectatthepressofabuttonandarepermanently linked.ThethermostatandPTACworkin-synctodisplayaccuratetemperature.
TheDigiSmartWirelessAntennainstallsinsidethePTACwithasnap-inconnector.InstallingtheantennaallowsthePTACtocommunicatewirelesslywithotherdevicesintheroomandtotheDigiSmartnetwork.>45,000+roomshavehadwirelessinstallationssince2005>Totalwirelessdevicesdeployedtodate:120,000+
TheAmanabrandDigiSmart PTACwith antenna, combinedwith the self-installable,wireless Thermostat andOccupancySensorgivethepropertyownercompletecontrolovertheequipmentsettingsandcanreducePTACenergyusageby35%ORMORE.*
siTe-level —cenTral wireless conTroller
>Site-widePTACConfiguration>Site-widePTACDiagnostics>FrontDeskSystemInterface>EmailReporting>InternetAccessibleWebUserInterfaceEnterprise
*ThesesavingsrepresentestimatedsavingsovertimeascomparedtothesamePTACmodelwithouttheDigiSmartEMSSysteminstalledandweregeneratedusinggeneralassumptionsincludingenergyloads,localweatheraveragesanduseofoccupancycontrols.Actualsavingswillvaryaccordingtoactualusehabits,roomsquarefootage,andhowtheunitisinstalled.
CT-DPTAC www.amana-ptac.com 5
enTerPrise — mulTiPle wireless conTrollers
CentralMonitoringandControlofMultipleProperties
>DataWarehousing>SavingsAnalysis>EmailReporting>VirtualMetering>LoadShedding
weB-Based, real-Time moniToringamana® Brand digismarT™ conTroller:AllofthePTACsinthebuildingcanbemanagedthroughasingleinterfaceonaPC.
FEATURESINCLUDE:FullunitdetailsforeveryPTAC,visiblefromthefrontdeskorhomeoffice,automaticemailsforPTACmaintenance,abilitytochangeallsettingsontheunit,andenhanceddiagnostics.Monitorupto170PTACs,WIRELESSLY,withonecontroller.Additionalcontrollerscanexpandthenetworkforadditionalrooms/properties.
>SystemVerification>GlobalSetbacks>EMSConfiguration>SiteStatistics>BatteryNotices>EmailReporting>UnitHealth>UnitCodeAlerts
Temp Limiting – Each PTACcanbeconfiguredwithaheat-ing and cooling temperatureset-pointlimit.Setbacks – Once a room isdeclaredunoccupiedbytheoccupancysensor,thePTACprogressesthroughthreedifferenttemperaturesetbacks,configuredasthreedegreeandtimepairs(Anexampleconfigurationislistedbelow).1st:2°,30mins–Setbackthetemp2degreesafter30minutes2nd:4°,1hr–Setbackthetemp2moredegreesafter30moreminutes3rd:8°,3hrs–Setbackthetemp4moredegreesafter2morehoursUnrentedSet-Points–Byintegratingwithyourproperty'sFrontDeskSystem,thePTACswilladjusttospecificset-pointswhennolongeridentifiedasrentedinthesystem.
6 www.amana-ptac.com CT-DPTAC
accessories
WallSleevesAllourwallsleeveshaveindustrystandarddimensionsof42”widex16⅟₁₆”high.AllStonewoodBeigeG-90metalwallsleevesarethermallyinsulatedand includeaweatherboard foruseduring construction.TheWS900D,SCandINTERNAL14⅛”depthistheindustrystandard.Sleeves may be shipped separately to allow for installation duringconstruction.
StandardDepthSleeves
WS900E StandardPTACsleeve
WS900SC Seacoasttripleprotected
WS900D-INTERNAL
Internaldrainonlyforwindow-wallinstallations(DK900Dsoldseparately)
ExtraDeepSleevesWeoffer sleeves in several depths for thickerwallinstallationsorspecialroomconfigurations
WS9xxD1 16”to24”in1”increments
WS928D1 Extradeep28”
WS930D1 Extradeep30”
WS936D1 Extradeep36”
14⅛"42"
161 /
16"
OutdoorGrillesAvailable in stamped-aluminum or architecturally louvered forapplicationwithanAmanabrandWS900Dwallsleeve.AGK—Extrudedaluminumarchitecturalgrilleavailablewithanod-
izedaluminumfinishorabaked-onpaintfinishfordurability.Choosefrom3stockcolorsoracustomcolortoblendwithyourbuilding’sexteriorcolorscheme.Colorsinclude:CB(ClearAnodized),DB(DarkBrown/Bronze)TB(StonewoodBeige),WB(White),SB(Special/CustomColors)
PGK—One-pieceinjectionmoldedgrilleusingapolymerblendofengineeredthermoplastichigh-impactstrengthmaterialwithchemicalresistanceandanexteriorUVprotectivecoating.Choosefrom3stockcolors:DB(DarkBrown/Bronze),TB(StonewoodBeige),WB(White)
StandardOutdoorGrille
SGK01B SinglePackSGK01TB StonewoodBeige
ArchitecturalOutdoorGrille
AGK01CB AnodizedAluminum(Silver)AGK01DB DarkBronze/BrownAGK01TB StonewoodBeigeAGK01WB AmanaWhiteAGK01SB CustomColorsPGK01DB DarkBronze/BrownPGK01TB StonewoodBeigePGK01TB AmanaWhite
AGKorPGK
SGK
CondensateDrainKitAttachestothewallsleevebasepanforcontrolledinternalorexternaldisposalofcondensate.
DK900DCondensateDrainKit(usewithWS900E)
DK9001DCondensateDrainKit(usewithWS900B)
DK900D
Low-VoltageWireHarnessKit(notshown)For quick connections of the remote, orwired, thermostats, wiredEMS,orfrontdeskwithjumpersandconnectors.
PWHK01C WireHarnessKit
RemoteEscutcheonKit(notshown)Optional kit for use with units controlled via a wired, remotethermostat. Covers control touch-pad for wired thermostatinstallations.
REK10B RemoteEscutcheonKit(10-pack)
Eachkitcontains80wiresandwirenuts,enoughtoattachathermostatandoneadditionalaccessoryto10PTACunits.
Wirescomeinassortedcolorsforeasyattachment.
Sub-baseKitThe fully skirted sub-base conceals wiring while providing strongsupport,ifneeded.Plug-inreceptacleandfield-wiringaccessspeedsinstallation. Electrical accessories, such as fuse holders, circuitbreakersanddisconnectswitches,meetN.E.C.requirements.
PTSB320E 230/208V15/20APTSB330E 230/208V30APTSB420E 265V15/20APTSB430E 265V25APTSB000E Non-electrical
Skirting Skirting
Leveling Legs
Optional Fuse Holder Location
Optional Power Switch and Circuit Breaker Location
Power Receptacle
Subbase Box Assembly
LevelingLegsGives wall sleeve front support and helps to level the unit forinstallation.
LL2B LevelinglegsforWS9**sleeves
CT-DPTAC www.amana-ptac.com 7
accessories (conT.)
Hard-wireKitsUsedtopermanentlywiretothechassiswhenastandardsub-baseandpowercordarenotutilized.
PTPWHWK4 ArmoredCable-allvoltages
PTQC03A QuickConnect-230/208V
PTQC04A QuickConnect-265&115V
PowerDisconnectSwitchThePSHW**Apowerdisconnectswitchcanbeusedfor265-voltor230/208-volt physical disconnect, where required by local codes.Theswitchisratedat30-ampcapacity.TheswitchisforusewithandAmana®brandstandardsub-basesorPTPWHWK4HardWireKit.
PSHW03A 230/208V
PSHW04A 265V
FuseHolderKitCartridge-stylefusescanbeinstalledinthefuseholderforuseinthesub-baseorchassis.Availablein15,20and30amp(includedon265-voltunit).
FHK315C 230/208V15A
FHK315E 230/208V15A(R-410A)
FHK320C 230/208V20A
FHK320E 230/208V20A(R-410A)
FHK330C 230/208V30A
FHK330E 230/208V30A(R-410A)
CircuitBreakerKit(230/208Vonly)Thecircuitbreakerkit, available in15,20or30 amp, canbeusedwithAmanabrandsub-bases.Itgivesovercurrentprotection,anditslocationallowsyoutoturntheunitonoroffwithouttools.
CBK3**C CircuitBreakerKit
DuctExtensionKitExtendsairdistributiontoanadjoiningroom.Consistsofamainductfortheroomoforiginandanextensionducttoreachtheadjoiningroomandterminalduct.PTDK01Aallowsforthenew“B”seriesunittoworkwiththe“A”seriesductkits.
MDK02B MainDuct–R-22
MDK01E MainDuct–R-410A
EDK02B ExtensionDuct
TRANSITION BAFFLES
MainDuctKit
TDK02B TerminalDuct
PTDK01A TransitionDuctOnly–R-22
PTDK01E TransitionDuctOnly–R-410A
ExtensionDuctKit
TerminalDuctKit
PowerVentKitInstallationofPowerVentincreasesCFMuptoapproximately95.Ventdoorwillautomaticallyclosewhenunitfanisoff.
R-410Amodelsmusthavethesekitsinstalledatthefactory.
PVK3A 230/208V–R-22
PVK4A 265V–R-22
CondenserBaffleKitForuseonnon-baffledgrilles.Thesedeflectorsdirecttheairintowardthecenterandawayfromtheinlettopreventrecirculationofthehotcondenserair.
DGK1B CondenserBaffleKit
Basepan
Condenser
Condenser Baffles
8 www.amana-ptac.com CT-DPTAC
accessories (conT.)
Sub-baseExtensionCoverKitConvertsolder30-ampsub-basestoallowforinstallationofthelarger30-ampLCDIpowercordandplugs.
SBEC10A 10Pack
CondensateRemovalPumpCanbefield-installed.Assists in removingcondensatedevelopedbyheatpumpoperationandtransfers ittoindoorcoiltodissipateintoroomwhileaddinghumiditytotheroom.
CDP302 230/208V–R-22
CDP402 265V–R-22
CDP302E 230/208V–R-410A
SecurityKeyLocksIn conjunction with the tamper-resistant front, the installation ofAmana®brandsecuritykeylockspreventstamperingofthecontrolsusedtosettemperature,heatingandcoolingfunctions.ULapprovedforinstitutionaluseonly.
KL03B SecurityKeyLock(R-22)
KL03E SecurityKeyLock(R-410A)
ThermostatsThefollowingthermostatsofferremotecontrol.AnythermostatotherthanthoselistedmustbesubmittedtoGoodmanCompany,L.P.,forapprovalpriortouse.
Model#Heat
StagesCoolStages
FanSpeed
#ofWiresRequired
TempLimiting
Backlit Display TypeShape&
OrientationConnection
2246002 1 1 1 5 No Yes Digital Manual Rect./Horiz. Wired
2246003 2 2 2 7 Yes Yes Digital Manual Rect./Horiz. Wired
2246007 2 2 2 7 Yes Yes Digital Auto-Change Rect./Horiz. Wired
2246008 2 2 2 7 Yes Yes Digital Programmable Rect./Horiz. Wired
DS01E 2 2 2 0 Yes Yes Digital Manual Rect./Horiz. Wireless
HydronicHeatKitAdd-on kits fit all units allowing the addition of hydronic water orhydronic steam heat to cooling and heating units. The kits featureleft-or right-handpiping.Unit retains complete serviceaccesswitha kit installed. Unit must be connected to and operated by a wallthermostat.
HWK03B HydronicWaterKit–R-22
HVK03B HydronicSteamKit–R-22
HWK03E HydronicWaterKit–R-410A
HVK03E HydronicSteamKit–R-410A
HydronicHeatKit-SideView
HydronicHeatKit-TopView
HydronicHeatKit-RightView
CT-DPTAC www.amana-ptac.com 9
accessories (conT.)
PowerDoorKitVentdoorwillautomaticallyopenwhenunitfanison.
PDK3A 230/208V–R-22
PDK4A 265V–R-22
PDK3E 230/208V–R-410A
PDK4E 265V–R-410A
HydronicValvesWaterandsteamvalvesareavailableforusewiththeHWK03(water)andHVK03(steam)heatkits.
VS2WNCA* 2-way/24V/NC/Steam
VS2WNOA* 2-way/24V/NO/Steam
VW2WNCA* 2-way/24V/NC/EndSwitch
VW2WNOA* 2-way/24V/NO/EndSwitch
VW3WNC2B* 3-way/24V/NC/NO/EndSwitch
*PoptopActuator
WirelessRF(RadioFrequency)ControlsAllDigiSmartPTACscomefactory-readytobecontrolledviawirelessRFdevices.2.4Ghz80215.4protocolassuresrobustcommunicationsandresponse.
DS01E Thermostat:2-waycommunications
DD01E OccupancySensor:EMSactivation
DT01A Antennae/Router
GT01A GenericRadioAntenna/Router
DD01F DoorSwitch:EMSActivation
DP01E Web-enabledPlatformServer
DL01E Web-enabledPlatformServerLink
RemoteTemperatureSensorUnitcanbewiredtosenseroomtemperatureawayfromthePTACtohaveaccuratereadings.
RTS03 Remotewall-mountedsensor
WiredEnergyManagementControlIncludesPIRoccupancysensorpowerfromtheDigiSmartcontrolanddoorswitch;cannotbeusedwitharemotewiredthermostat.
WEMR01W Recess-mounteddoorswitch
WEMS01B Surface-mounteddoorswitch(Brown)
WEMS01W Surface-mounteddoorswitch(White)
WallSleeveExtensionAdapterKitsRoom-sideextensionkitstoincreasethedepthoftheexistingsleevetoallowforanindustry-standardPTACtobeinstalled.
SECM1001A ClimateMaster12½”SleeveExtension(10Pack)
SEZA0501A ZoneAire11½”SleeveExtension(5Pack)
CurtainBaffleKitThecolormatchedpolymercurtainbaffleshelp toprevent curtainsfrom falling into thedischargeair streamand causing recirculation,reducingefficienciesandshorteningcompressorlife.
PTCB10B 10PackforR-22units
PTCB10E 10PackforR-410Aunits
10 www.amana-ptac.com CT-DPTAC
Power cord conFiguraTion
inTake air FilTersItisextremelyimportanttocleantheinletairfiltersonceamonth(ormoreoftenifoperatedindustyordirtylocationsorconditions) toproperlymaintain theoperationalperformanceof thePTACunit. The two intakeairfilters (constructedofdurablepolypropylene)canbeeasilyinsertedintothecabinetfrontusingthecabinetfilterguides.Beforecleaningtheintakefilters,turntheunitoffbysettingthemodeswitchtotheOFFposition.Filtersshouldbecleanedasrequired.Thefollowingprocedureisusedtoremovetheintakefilters:1.Facingtheunit,pulluponthefilterhandleslocatedatthefronttopoftheunit.2.Pulleachfilterupwardandremove.3.Cleanfilterswithvacuumorwithrunningwater.Reversethisproceduretoreinstallthefilters.
Note:Accessoryfilterkitsareavailablefromyoursalesperson.Allfiltersarepermanentandcleanable.ConsultyourI&OManualforothermonthlycleaninginstructions.
monTHly mainTenance
sPare FilTers Helpskeepdirtandlintoutoftheairandoffthecoil,thus increasing the unit's efficiency. Amana® brandfiltersareeasytoremove,washandreplace.
FK10A 10-pack-ASeries
FK10B 10-pack-B,C&DSeries
FK10E 10-pack-ESeries(Thismodelrequires2filtersperchange.)
rePlacemenT cHarcoal FilTer kiTAbsorbs airborne odors caused by cigarette, pipeor cigar smoke and odors caused by mold, mildew,etc. Filters aremadeof polyester fibers coatedwithactivated charcoal and are individually wrapped.These filters are permanent and can be washed orcleaned. Call your Amana® brand PTAC sales personfordetails.10filtersperpack.
CFK10A 10-pack-ASeries(R-22)
CFK10B 10-pack-B,C&DSeries(R-22)
277V Rating Power Cord PlugsNEMA 7 Configuration
G
W
20 amp
G
W
30 amp
250V Rating Power Cord Plugs with LCDI DeviceNEMA 6 Configuration
Power Cord Plugs
15 amp 20 amp 30 amp
Power Receptacle Configuration
NEMA6-15R;250Vreceptacleusedon230/208Vunits
NEMA6-20R;250Vreceptacleusedon230/208Vunits
NEMA6-30R;250Vreceptacleusedon230/208Vunits
NEMA7-20R;277Vreceptacleusedon265Vunits
NEMA7-30R;277Vreceptacleusedon265Vunits
All units come with factory-installed power cords.Allunitslessthan250voltscomewithLCDIdevice.
CT-DPTAC www.amana-ptac.com 11
noTes
12 www.amana-ptac.com CT-DPTAC
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commit- ment to quality products may mean a change in specifications without notice. © 2012 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.
Packaged Terminal air condiTioners and HeaT PumPs
wiTH conTrol Board
7-Button Control Pad• One-TouchActivation• TotalFanControl• Easy-to-ReadDisplay
First-YearWarranty:Parts&LaborSecondthroughFifthYear:Parts&LaboroncertainsealedsystemcomponentsSecondthroughFifthYear:oncertainfunctionalpartsonly*Completewarrantydetailsavailableatwww.amana-ptac.com.