with ecotherm insulation...it’s thin superior rigid insulation built in membrane no need for a...
TRANSCRIPT
FOR WALLS
SLIMLINE
FOR FLOORS
BASELINE
FOR ROOFS
TOPLINE
Specify for the future
2013
with EcoTherm Insulation
Insulation
Application Product
Single Ply
Cavity wall
Internallining
Eco-Cavity p12
Eco-Liner p10
Eco-Versal p8
Eco-UFH p9
PitchedRoofs
FlatRoofs
Eco-Versal p13
Mastic asphalt
Eco-Taper p19Eco-Metre p14Eco-Felt p15Eco-Deck p18
Eco-Taper p19Eco-Metre p14Eco-Felt p15Eco-Deck p18
Torch on
Roll & pour
Eco-Taper p19Eco-Metre p14Eco-Felt p15Eco-Deck p18
Eco-Taper p19Eco-Metre p14Eco-Felt p15Eco-Deck p18
Mechanically fixed
Adhered
Bitumencompatible
Eco-Deck p18Eco-Fix p17
Eco-Taper p19Eco-Bond p16Eco-Deck p18
Felt
FOR WALLS
SLIMLINE
FOR FLOORS
BASELINE
FOR ROOFS
TOPLINE
www.ecotherm.co.uk tel: 01702 5201662 32013
FOR WALLS
SLIMLINE
FOR FLOORS
BASELINE
FOR ROOFS
TOPLINE
Keeping heat in and cold out – EcoTherm has it covered
Contents
Products selector 3
PIR board – meeting Building Regulations 4
Environment – dedicated to responsibility 6
Baseline – for floors
Eco-Versal 8
Eco-UFH 9
Slimline – for walls
Eco-Liner 10
Eco-Cavity 12
Topline – for roofs
Eco-Versal 13
Eco-Metre 14
Eco-Felt 15
Eco-Bond 16
Eco-Fix 17
Eco-Deck 18
Eco-Taper 19
Technical support 20
EcoTherm develops, manufactures and markets
Polyisocyanurate Rigid Thermal Insulation Boards.
In addition to our standard range of products we
also produce speciality products.
EcoTherm rigid insulation boards are produced in both the UK and The Netherlands
for the UK market. Rigorous quality control procedures are in place in both
production facilities.
EcoTherm products are recognised for their compressive strength and dimensional
stability which makes them ideally suited to flat and pitched roof construction, wall
insulation and for floors and ceilings.
All these applications are supported at every stage with comprehensive technical
advice and customer service.
PIR foam insulation materials may be considered to be the most sustainable, in that they do not affect the ozone layer and they perform for the life of the building without loss of performance. See page 6.
Select your productThe future of insulation
Insulation
Meeting the insulation demands of Building Regulations
In the past, understanding how to meet the
requirements of Building Regulations for thermal
insulation was relatively straightforward. A table
would tell you the U-value that needed to be
achieved for a particular floor, wall or roof and the
manufacturer could then tell you what thickness
of insulation you needed to achieve that value.
As green issues and the threat of global warming
have come to the top of the agenda, however,
the approach has changed and the requirements
have not only become tougher, but also harder to
put into a simple formula.
The current Part L of the Building Regulations
(Conservation of Fuel and Power) came into effect
in 2006 and represents the Government’s response
to the EU’s Energy Performance of Buildings
Directive. It applies to all new buildings – dwellings
and commercial – as well as building work on
existing buildings.
The new requirements mean developers have to
use more energy saving insulation, more efficient
boilers and low or zero carbon systems to
demonstrate compliance.
PIR based insulation boards offer many advantages
in meeting these requirements as they have a high
thermal insulation factor per unit mass and an
extremely long performance life.
Their light weight means they can be easily
used with modern construction methods,
while their durability means that the building
performs to the required level of energy efficiency
throughout its life – without the need for resource-
consuming replacements.
On new buildings Part L sets overall performance
standards rather than laying down particular ways
of achieving them. The old Elemental Method and
Target U-Value approach of determining whether a
building is compliant are no longer allowed.
Every new building now has to achieve a Target CO2
Emission Rate (TER) expressed in mass of CO2 per
unit floor area emitted by all the internal heating,
hot water, ventilation and fixed lighting. This is
calculated using either the Government’s Standard
Assessment Procedure (SAP 2005) for dwellings
smaller than 450m2, or the Simplified Building
Energy Model (SBEM) for non-domestic buildings.
EcoT herm appreciates that the removal of the old
step-by-step approach means that it is much harder
to know how to comply. To help our customers
meet these new requirements we are pleased to
offer our technical advice.
FOR WALLS
SLIMLINE
FOR FLOORS
BASELINE
FOR ROOFS
TOPLINE
For new buildings (England and Wales)
Likely required values and thicknesses to achieve TER
For new dwellings, in accordance with Building Regulations Approved
Document L1A, April 2006, the Dwelling CO2 Emission Rate (DER) must
be no more than the defined Target CO2 Emission Rate (TER). DER and
TER may be calculated by the Standard Assessment Procedure (SAP).
To achieve the most cost-effective DER will generally require 10 – 20
iterations to calculate the permissible U-values for each element of
roof, wall, and floor. Experience shows that it is sensible to start with
the insulation thicknesses shown above in order to minimise the
number of SAP iterations required.
For new buildings and work to existing buildings (Scotland)
For work under Scottish Regulations U-values for each wall, floor or
roof element must be no more than those in the illustration adjacent,
subject to certain other factors (i.e. the total area of doors, windows
and rooflights must be less than 25% of the total floor area and the
boiler or heating appliance must have an efficiency not less than 78%
by SEDBUK calculations).
For all buildings (Scotland) and for work in existing buildings (England and Wales)
Required thicknesses to achieve elemental U-values
For work to existing buildings in accordance with Building Regulations
Approved Document L1B and L2B, U-values for each wall, floor or roof
element must be no more than those in the illustration adjacent.
www.ecotherm.co.uk tel: 01702 5201664 5
PIR board
BBA CertificationEcoTherm Insulation boards
are fully supported with a
British Board of Agrément
Certificate.
U-value = 0.25Thickness = 50 – 80mm dependent on floor P/A
U-value = 0.16Thickness = 130mm
U-value = 0.20Thickness = 100mm
England and Wales existing walls
U-value = 0.35
England and Wales new extension walls
U-value = 0.30
England and Wales new existing walls
U-value = 0.30
U-value = 0.35Thickness = 50mmUnheated space e.g. garage
U-value = 0.25Thickness = 80 – 110mm
U-value = 0.20 – 0.22Thickness = 50 – 80mm dependent on floor P/A
For new buildings other than dwellings (England and Wales)
To comply with ADL2A the Building CO2 Emission Rate (BER) must be
no more than the Target CO2 Emission Rate (TER). Experience shows
that the insulation thicknesses shown above are likely to be acceptable
in a Simplified Building Energy Model (SBEM) calculation.
Sensible starting point for calculations to meet TER
Element U-value (W/m2K) Thickness (mm)
Wall 0.25 – 0.30 50 – 70
Floor 0.20 – 0.22 50 – 80*
Roof 0.16 – 0.20 110 – 130
*Dependent on floor perimeter/area measurement
U-value = 0.20 – 0.22Thickness = 50 – 80mm dependent on floor P/A
U-value = 0.16Thickness = 130mm
U-value = 0.16 – 0.18Thickness = 120 – 130mm
U-value = 0.25 – 0.30Thickness = 50 – 70mm
U-value = 0.25 – 0.30Thickness = 65 – 70mmUnheated space e.g. garage
U-value = 0.18 – 0.20Thickness = 110 – 130mm
U-value = 0.20 – 0.22Thickness = 50 – 80mm dependent on floor P/A
For all buildings (Scotland) and for work in existing buildings
(England and Wales)
For new buildings (England and Wales)
FOR FREE TECHNICAL ADVICE Call: 01268 597 212/213Email: [email protected]
Insulation
2013
BRE Green guide 'A' ratedEcoTherm is fundamentally dedicated to environmental responsibility by minimising energy consumption.
Our polyisocyanurate (PIR) products are among the most efficient and effective means of minimising
energy loss from buildings.
EcoTherm has achieved ISO 14001 accreditation; a reflection of the entire organisations commitment to
sustainability through their Environmental Management System.
All our insulation boards are manufactured from CFC- and HCFC-free grades of material which ensure zero ozone
depletion potential (ZERO ODP) and a global warming potential (GWP) factor of 3 which comfortably surpasses the
target of 5 and is BRE Green Guide A rated.
Whenever we use timber, such as in our Eco-Deck laminated roof decking, it is Forest Stewardship Council (FSC)
certified, which gives assurance that it is legal and sustainable at every stage of its chain of custody.
Wide experience supported by accelerated lab tests have proved that PIR insulation boards are among the most
durable construction products.
They will not rot, shrink, absorb moisture, or decay as some fibre board or organic insulation materials may, and so
they will deliver design insulation values throughout the full life of the building. And of course all our products are
recyclable. In practice PIR products have one of the highest ratings for successful recycling.
" Within 8 months users will
have recouped the energy
required to produce the
EcoTherm product in
energy savings."
FOR WALLS
SLIMLINE
FOR FLOORS
BASELINE
FOR ROOFS
TOPLINE
Environment
www.ecotherm.co.uk tel: 01702 5201666 7
"1m3 of PIR saves 40km3 of CO2. That’s 60kg of CO2 over 75yrs –
50% more than traditional insulation."
FOR FREE TECHNICAL ADVICE Call: 01268 597 212/213Email: [email protected]
EMS 564550
Insulation
2013
IT’S THINsuperior rigid
insulation
BUILT IN MEMBRANEno need for a polythene
overlay
SUPERB CLIPRETENTIONheavy duty facing holds clips tight
www.ecotherm.co.uk tel: 01702 5201668 9
FOR FLOORS
BASELINE
FOR FLOORS
BASELINE
Eco-Versal formerly Floor-Therm
Cert 99/3569Benefits
■ Maximum insulation
performance for
minimum thickness
■ Good compressive strength
(140kpa for Eco-Versal and
160kpa for Eco-UFH)
■ High resistance to
compressive creep
■ Adaptability in
modern constructions
■ Flexibility to insulate
most floors
■ Meets NHBC
recommendations
■ Meets UK Building
Regulation standards
Dimensions
Width (mm): 1200
Length (mm): 2400
Thickness (mm): 25 – 200
Design considerations
BRE Good Building Guide 45,
Insulating ground floors.
CP 102:1973 Code of Practice for
protection of buildings against
water from the ground.
Compressive strength
Typical compressive strength
exceeds 140kPa for Eco-Versal
and 160kPa for Eco-UFH, when
tested to BS EN 826: 1996.
U-values
The calculation of U-Values
for floors depends on the
substructure and perimeter/
area. Therefore, it is not possible
to give accurate values.
Thermal conductivity
The thermal conductivity,
λ value is 0.022W/mK.
Thermal insulation for floors
Description: Rigid PIR core with an aluminium foil facing on both sides
Purpose: Solid concrete floors, suspended hollow pot floors, suspended timber
floors, foundations and perimeters, remedial overlay floors
Thermal insulation for underfloor heating
Description: Rigid PIR foam core with tough woven aluminium grid
Purpose: Insulating under floor heating systems and providing
a mechanism for servicing water pipes
Eco-UFH formerly Underfloor Heating
Benefits
■ Eco-UFH Board has a rigid PIR
foam core which gives the
highest thermal performance
for the minimum thickness
■ It has a tough woven grid and
aluminium facing which holds
clips tight and reduces the
number of clips required
■ Its high compressive strength
(160kPa) means it stands up
to foot traffic
■ Eco-UFH Board ensures the
performance of the system
by preventing heat loss
penetrating the floor; it saves
energy and money by
distributing heat evenly
Dimensions
Width (mm): 1200
Length (mm): 2400
Thickness (mm): See below
Design considerations
BRE Good Building Guide 45, Insulating ground floors. CP 102:1973
Code of Practice for protection of buildings against water from
the ground.
Thermal conductivity
The thermal conductivity, λ value, of EcoTherm Eco-UFH is typically
0.022W/mK. The thermal resistance 'R' varies with the thickness as
shown in the table below.
Solid and Suspended Block & Beam = UFH
All calculations based on a P/A ratio of 0.5
PRINTED GRIDmakes it easier
to align the pipes
Thickness Length Width R-value Typical Typical U-value Typical U-value (mm) (mm) (mm) (m2k/W) U-value Suspended Suspended Solid Concrete B&B Timber Floor (W/m2k) (W/m2k) (W/m2k)
25 2400 1200 1.14 0.36 0.40 0.39
30 2400 1200 1.36 0.33 0.37 0.36
35 2400 1200 1.59 0.31 0.34 0.34
40 2400 1200 1.82 0.28 0.31 0.32
45 2400 1200 2.05 0.27 0.30 0.30
50 2400 1200 2.27 0.25 0.27 0.29
60 2400 1200 2.73 0.22 0.24 0.26
65 2400 1200 2.96 0.21 0.23 0.25
70 2400 1200 3.18 0.20 0.22 0.25
75 2400 1200 3.41 0.19 0.21 0.24
80 2400 1200 3.64 0.19 0.20 0.23
90 2400 1200 4.09 0.17 0.18 0.22
100 2400 1200 4.55 0.16 0.17 0.21
110 2400 1200 5.00 0.15 0.16 0.20
120 2400 1200 5.46 0.14 0.15 0.19
130 2400 1200 5.91 0.13 0.14 0.18
140 2400 1200 6.36 0.12 0.13 0.18
150 2400 1200 6.82 0.12 0.12 0.17
160 2400 1200 7.27 0.11 0.12 0.15*
170 2400 1200 7.73 0.11 0.11 0.15*
180 2400 1200 8.18 0.10 0.10 0.14*
190 2400 1200 8.64 0.10 0.10 0.14*
200 2400 1200 9.09 0.09 0.10 0.14*
Thickness Length Width R-value Typical U-value Typical U-value
(mm) (mm) (mm) (m2k/W) Solid (W/m2k) Suspended B&B (W/m2k)
25 2400 1200 1.14 0.36 0.40
30 2400 1200 1.36 0.33 0.37
35 2400 1200 1.59 0.31 0.34
40 2400 1200 1.82 0.28 0.31
50 2400 1200 2.27 0.25 0.27
60 2400 1200 2.73 0.22 0.24
75 2400 1200 3.41 0.19 0.21
80 2400 1200 3.64 0.19 0.20
90 2400 1200 4.09 0.17 0.18
100 2400 1200 4.55 0.16 0.17
FOR FREE TECHNICAL ADVICE Call: 01268 597 212/213Email: [email protected]
BASELINE BASELINE
All calculations based on a P/A ratio of 0.5 * 200mm deep timbers
Insulation
2013
Benefits
■ Insulate and dry line in one
■ Thin insulation solution
where space matters
■ Quick and cost effective
Dimensions
Width (mm): 1200
Length (mm): 2400
Thickness (mm): 37.5 – 112.5
Design considerations
Cut using a fine tooth saw,
ensuring accurate trimming to
achieve close butt joints and
continuity of insulation.
Follow BS 8212: 1995 Code
of Practice for dry lining and
partitioning using gypsum
plasterboard and BS 8000-Part 8:
1994 Workmanship on building
sites. Code of practice for
plasterboard partitions and dry
linings. If required for acoustics
and air tightness apply a suitable
parge coat prior to lining.
Compressive strength
Typical compressive strength
for the foam exceeds 140 kPa
when tested to BS EN 826: 1996
Thermal Insulating Products
for Building Applications –
Determination of
Compression Behaviour.
U-values
The calculation of U-values
for walls depends on the
substructure. Therefore, it is not
possible to give accurate values.
Thermal conductivity
The thermal conductivity
(λ value) of the foam is
0.022W/mK with inherent
vapour control resistance.
The 12.5mm gypsum
plasterboard element has a
thermal conductivity (λ) of
0.19W/mK. The thermal
resistances of the Eco-Liner
range of laminates are shown in
the table on the opposite page.
Thermal insulation for dry lined internal walls
Description: Polyisocyanurate foam core faced on one side with
12.5mm tapered edge gypsum plaster board.
Composite insulated panel comprising PIR foam
bonded to 12.5mm tapered edge gypsum
plasterboard for internal dry lining applications
for solid walls.
Purpose: Dab and mechanically fixed dry lining applications for
improving thermal performance
Figure 1
Figure 2
FOR WALLS
SLIMLINE
www.ecotherm.co.uk tel: 01702 52016610 11
Eco-Liner
FOR WALLS
SLIMLINE
FOR FREE TECHNICAL ADVICE Call: 01268 597 212/213Email: [email protected]
NEWSLIMLINE
Eco
-Lin
er • NEW
Eco-Liner • NEW
Insulation
Eco-Liner - Mechanically Fixed to Timber Battens
Eco-Liner - Dot & Dab Application
Insulation Total R-value U-value
thickness (mm) thickness (mm) (m2K/W) (W/m2K)
25 37.5 1.212 0.55
30 42.5 1.440 0.49
35 47.5 1.667 0.44
40 52.5 1.894 0.40
45 57.5 2.121 0.37
50 62.5 2.349 0.34
55 67.5 2.576 0.31
60 72.5 2.803 0.30
65 77.5 3.031 0.28
70 82.5 3.258 0.26
75 87.5 3.485 0.25
80 92.5 3.712 0.23
90 102.5 4.167 0.21
100 112.5 4.621 0.19
Insulation Total R-value U-value
thickness (mm) thickness (mm) (m2K/W) (W/m2K)
25 37.5 1.212 0.57
30 42.5 1.440 0.51
35 47.5 1.667 0.45
40 52.5 1.894 0.41
45 57.5 2.121 0.37
50 62.5 2.349 0.35
55 67.5 2.576 0.32
60 72.5 2.803 0.30
65 77.5 3.031 0.28
70 82.5 3.258 0.26
75 87.5 3.485 0.25
80 92.5 3.712 0.23
90 102.5 4.167 0.21
100 112.5 4.621 0.19
Calculations are based on a 215mm thick solid brickwork wall and includes a 2mm plaster skim coat. Timber battens are 25x50mm at 600mm Centres
2013
www.ecotherm.co.uk tel: 01702 52016612 13
FOR WALLS
SLIMLINE
Cert 98/3552 Cert 99/3569
FOR ROOFS
TOPLINE
Benefits
■ Facings improve the
thermal resistance of
the retained cavity
■ Produced in sizes which
combine accurately with
standard sized bricks/blocks
■ Maximum insulation for
minimum thickness within
construction depth
■ Offers excellent
thermal resistance in
practical thicknesses
■ Tough, light and easily fitted
using standard wall ties or
simple clipping methods
■ Easily achieves the UK
Building Regulations
thermal standards
Dimensions
Width (mm): 450
Length (mm): 1200
Thickness (mm): 25, 30, 35, 40, 45, 50, 55, 60, 70, 75, 100
Design considerations
A minimum 25mm cavity should always be maintained after the installation of EcoTherm Eco-Cavity lining board,
irrespective of the thickness specified. This will avoid problems associated with completely filled cavities.
BS 5628-1: 2005 Code of Practice for structural use of un-reinforced masonry and BS 5628-2: 2005 structural
use of reinforced and pre-stressed masonry should be consulted, NHBC require 50mm residual cavity.
Wall ties
Wall ties should be long enough to provide a minimum 75mm bed into the mortar joints of the inner skin and
50mm into the outer skin mortar bed. The specified ties should conform to BS EN 845-1:2003 and A1:2008
Specification for ancillary components for masonry ties tension straps, hangers and brackets.
Thermal conductivity
The λ value is typically 0.022W/mK, R varies with thickness, and U-value in traditional masonry cavity walls
with a minimum 25mm cavity is as shown below.
Thermal insulation for cavity walls
Description: Rigid polyisocyanurate foam core with
aluminium foil composite on both sides
Purpose: Partial fill cavity wall insulation
Eco-Cavity formerly Cavity-Wall
Thermal insulation for pitched roofs, floors and ceilings
Description: Polyisocyanurate foam core with aluminium foil
composite on both sides
Purpose: For warm / cold pitched roofs loft ceilings
and floors
Eco-Versal formerly Pitched Roof
Benefits
■ Allows traditional forms of
construction without modern
problems of condensation
■ EcoTherm Eco-Versal can be
used to insulate the roof and
cheeks of dormers and
ceilings
■ Roofs insulated at rafter level
create a warm roof; no pipe
or tank lagging is required
■ Can also be used in cold
pitched roof applications
Dimensions
Width (mm): 1200
Length (mm): 2400
Thickness (mm): 25 - 200
Design considerations
In all over-rafter applications counter battens should be positioned above the EcoTherm Eco-Versal insulation
boards to separate the breathable membrane from the board.
Thermal conductivity
The thermal conductivity, λ value, of EcoTherm Eco-Versal is typically 0.022W/mK. The thermal resistance 'R'
varies with the thickness as shown in the table below.
Thickness Length Width R-value Typical U-value Typical U-value Typical U-value
(mm) (mm) (mm) (m2k/W) light block medium block dense block
(W/m2k) (W/m2k) (W/m2k)
25 1200 450 1.14 0.34 0.41 0.43
30 1200 450 1.36 0.31 0.37 0.39
35 1200 450 1.59 0.29 0.35 0.36
40 1200 450 1.82 0.27 0.32 0.33
45 1200 450 2.05 0.26 0.30 0.31
50 1200 450 2.27 0.24 0.28 0.29
55 1200 450 2.50 0.23 0.26 0.27
60 1200 450 2.73 0.22 0.25 0.25
70 1200 450 3.18 0.20 0.22 0.23
75 1200 450 3.41 0.19 0.21 0.22
100 1200 450 4.55 0.16 0.17 0.17
Thickness Length Width R-value Typical U-value single Typical U-value between and
(mm) (mm) (mm) (m2k/W) layer over rafters (W/m2k) 25mm under rafters (W/m2k)
25 2400 1200 1.14 0.60 0.36
30 2400 1200 1.36 0.52 0.34
35 2400 1200 1.59 0.47 0.32
40 2400 1200 1.82 0.42 0.30
45 2400 1200 2.05 0.39 0.29
50 2400 1200 2.27 0.36 0.27
60 2400 1200 2.73 0.31 0.25
65 2400 1200 2.96 0.29 0.24
70 2400 1200 3.18 0.27 0.23
75 2400 1200 3.41 0.25 0.22
80 2400 1200 3.64 0.24 0.22
90 2400 1200 4.09 0.22 0.20
100 2400 1200 4.55 0.20 0.19
110 2400 1200 5.00 0.18 0.18
120 2400 1200 5.46 0.17 0.17
130 2400 1200 5.91 0.15 0.16
140 2400 1200 6.36 0.14 0.15
150 2400 1200 6.82 0.14 0.15
160 2400 1200 7.27 0.13 0.14
170 2400 1200 7.73 0.12 0.13
180 2400 1200 8.18 0.11 0.13
190 2400 1200 8.64 0.11 0.13
200 2400 1200 9.09 0.10 0.12 FOR FREE TECHNICAL ADVICE Call: 01268 597 212/213Email: [email protected]
SLIMLINE TOPLINE
Insulation
2013
Cert 07/4487Cert 07/4487
FOR ROOFS
TOPLINE
FOR ROOFS
TOPLINE
Benefits
■ 1 board = 1m2 for easy
measurement
■ Polypropylene fleece side
up for torch on and mastic
asphalt systems
■ Bitumen tissue side up
for roll and pour and
bitumen compatible
single ply membranes
■ Maximum insulation for
minimum thickness
■ Roofs insulated with
EcoTherm Eco-Metre meet
the thermal requirements of
the UK Building Regulations
Dimensions
Width (mm): 834
Length (mm): 1200
Thickness (mm): 30 - 200
www.ecotherm.co.uk tel: 01702 52016614 15
Eco
Therm
Eco
-Metre 4 solu
tion
s in 1
Design considerations
These should be assessed
in accordance with the
BS 6399-2 1997.
Consideration should also be
given to BS 5250: 2002 Code
of Practice for control of
condensation in buildings and
BS 6229: 2003 Code of Practice
for flat roofs with continuously
supported coverings.
Mechanical fixings should be
specified as recommended in
BRUFMA information document
ID/1/2009 mechanical fixings
for rigid PIR roof boards.
Roof loading
Depending on the chosen
waterproofing system, EcoTherm
Eco-Metre is suitable for use on
roof decks that are subject to
limited maintenance foot traffic.
Walkways should be provided
on roofs requiring regular
pedestrian access.
The roof should be boarded out
with protective boarding
whenever site work is to take place
after the roofboard has been laid
and the roof made watertight.
Thermal conductivity
λ = 25-79mm = 0.026W/mK
80-119mm = 0.025W/mK
120mm + = 0.024W/mK
Benefits
■ EcoTherm Eco-Felt is a multi-
purpose roofboard suitable
for mastic asphalt or built-up
felt roofing
■ The core of EcoTherm
Eco-Felt roofboard is
temperature tolerant and
withstands the application
of hot bitumen to the surface
at up to 220°C
■ Roofs insulated with
EcoTherm Eco-Felt meet the
thermal requirements of the
UK Building Regulations
■ Maximum insulation for
minimum thickness
■ Simple application
Dimensions
Width (mm): 600
Length (mm): 1200
Thickness (mm): 30 - 200
Design considerations
These should be assessed
in accordance with
BS 6399-2 1997.
Consideration should also be
given to BS 5250: 2002 Code
of Practice for control of
condensation in buildings and
BS 6229: 2003 Code of Practice
for flat roofs with continuously
supported coverings. Mechanical
fixings should be used as
recommended in BRUFMA
information document
ID/1/2009.
Roof loading
Depending on the chosen
waterproofing system, EcoTherm
Eco-Felt roofboard is suitable for
use on roof decks that are
subject to limited maintenance
foot traffic. Walkways should be
provided on roofs requiring
regular pedestrian access.
The roof should be boarded out
with protective boarding
whenever site work is to
take place after the roofboard
has been laid and the roof
made watertight.
Thermal conductivity
λ = 25-79mm = 0.026W/mK
80-119mm = 0.025W/mK
120mm + = 0.024W/mK
Thermal insulation for flat roofs
Description: Polyisocyanurate foam core faced with bitumen/mineral on one
side and bitumen/polypropylene on the other
Purpose: Torch-on (fully and partially bonded) or roll and pour (fully and
partially bonded) asphalt and single ply bituminous systems
Thermal insulation for flat roofs
Description: Polyisocyanurate foam core faced with bitumenised glass coated
tissue on one side and plain glass tissue on the reverse
Purpose: For built-up felt roofing and asphalt applications
Eco-Felt formerly Multi-Therm
• Torch on • Roll & pour • Mastic asphalt • Single ply bitumen
compatibleEco-Metre
Thickness Length Width R-value Typical U-value Typical U-value Typical U-value
(mm) (mm) (mm) (m2k/W) on metal deck on concrete deck on timber deck
(W/m2k) (W/m2k) (W/m2k)
30 1200 834 1.15 0.72 0.68 0.57
40 1200 834 1.54 0.58 0.55 0.48
50 1200 834 1.92 0.47 0.45 0.40
60 1200 834 2.31 0.40 0.38 0.34
70 1200 834 2.69 0.35 0.34 0.31
80 1200 834 3.20 0.29 0.28 0.26
90 1200 834 3.60 0.26 0.26 0.24
100 1200 834 4.00 0.24 0.23 0.22
110 1200 834 4.40 0.22 0.21 0.20
120 1200 834 5.00 0.19 0.19 0.18
130 1200 834 5.42 0.18 0.18 0.17
140 1200 834 5.83 0.17 0.16 0.16
150 1200 834 6.25 0.15 0.15 0.15
160 1200 834 6.67 0.15 0.14 0.14
170 1200 834 7.08 0.14 0.14 0.13
180 1200 834 7.50 0.13 0.13 0.12
190 1200 834 7.92 0.12 0.12 0.12
200 1200 834 8.33 0.12 0.12 0.11
Thickness Length Width R-value Typical U-value Typical U-value Typical U-value
(mm) (mm) (mm) (m2k/W) on metal deck on concrete deck on timber deck
(W/m2k) (W/m2k) (W/m2k)
30 1200 600 1.15 0.72 0.68 0.57
40 1200 600 1.54 0.58 0.55 0.48
50 1200 600 1.92 0.47 0.45 0.40
60 1200 600 2.31 0.40 0.38 0.34
70 1200 600 2.69 0.35 0.34 0.31
75 1200 600 2.89 0.32 0.31 0.29
80 1200 600 3.20 0.29 0.28 0.26
90 1200 600 3.60 0.26 0.26 0.24
100 1200 600 4.00 0.24 0.23 0.22
110 1200 600 4.40 0.22 0.21 0.20
120 1200 600 5.00 0.19 0.19 0.18
130 1200 600 5.42 0.18 0.18 0.17
140 1200 600 5.83 0.17 0.16 0.16
150 1200 600 6.25 0.15 0.15 0.15
160 1200 600 6.67 0.15 0.14 0.14
170 1200 600 7.08 0.14 0.14 0.13
180 1200 600 7.50 0.13 0.13 0.12
190 1200 600 7.92 0.12 0.12 0.12
200 1200 600 8.33 0.12 0.12 0.11
TOPLINE TOPLINE
Insulation
2013
www.ecotherm.co.uk tel: 01702 52016616 17
Cert 07/4487Cert 07/4487
FOR ROOFS
TOPLINE
FOR ROOFS
TOPLINE
Benefits
■ Provides lightweight, warm-
roof constructions
■ Insulated roofs easily meet
the thermal requirements of
the UK Building Regulations
■ Provides lightweight, warm-
roof constructions
■ Compatible with fully-
adhered and mechanically-
fixed single ply non-
bituminous membranes
■ Maximum insulation for
minimum thickness
■ Simple application
Dimensions
Width (mm): 600, 1200
Length (mm): 1200, 2400
Thickness (mm): 30 – 200
Design considerations
These should be assessed in accordance with BS 6399-2 1997.
Consideration should also be given to BS 5250: 2002 Code of Practice for control of condensation in buildings
and BS 6229: 2003 Code of Practice for flat roofs with continuously supported coverings. Mechanical fixings
should be used as recommended in BRUFMA information document ID/1/2009.
U-values
Eco-Bond waterproofed with a singly ply membrane will give the typical insulation values shown in the
table below.
Thermal conductivity
λ = 25-79mm = 0.026W/mK
80-119mm = 0.025W/mK
120mm + = 0.024W/mK
Benefits
■ Provides lightweight, warm-
roof constructions
■ Insulated roofs easily meet
the thermal requirements of
the UK Building Regulations
■ For use with mechanically
fixed single ply membranes
■ Maximum insulation for
minimum thickness
■ Simple application
Dimensions
Width (mm): 1200
Length (mm): 2400
Thickness (mm): 30 – 200
Design considerations
These should be assessed in accordance with BS 6399-2 1997.
Consideration should also be given to BS 5250: 2002 Code of Practice for control of condensation in buildings
and BS 6229: 2003 Code of Practice for flat roofs with continuously supported coverings. Mechanical fixings
should be as recommended in BRUFMA information document ID/1/2009.
EcoTherm recommends the use of thermally broken tube fasteners.
Thermal conductivity
The thermal conductivity, λ value, of EcoTherm Eco-Fix is typically 0.022W/mK. The thermal resistance ‘R’
varies with thickness as shown in the table below.
Thermal insulation for flat roofs
Description: Polyisocyanurate (PIR) foam with a mineral coated
glass fibre tissue on both sides
Purpose: For fully bonded single ply membrane systems
Thermal insulation for flat roofs
Description: Polyisocyanurate foam core with aluminium foil face
composite on both sides
Purpose: For use with fully mechanically fixed single ply membranes
Eco-Fix formerly Foil-ThermEco-Bond formerly Glass-Therm
Thickness Length Width R-value Typical U-value Typical U-value Typical U-value
(mm) (mm) (mm) (m2k/W) on metal deck on concrete deck on timber deck
(W/m2k) (W/m2k) (W/m2k)
30 1200 600 1.15 0.72 0.68 0.57
40 1200 600 1.54 0.58 0.55 0.48
50 1200 600 1.92 0.47 0.45 0.40
60 1200 600 2.31 0.40 0.38 0.34
70 1200 600 2.69 0.35 0.34 0.31
80 1200 600 3.20 0.29 0.28 0.26
90 1200 600 3.60 0.26 0.26 0.24
100 1200 600 4.00 0.24 0.23 0.22
110 1200 600 4.40 0.22 0.21 0.20
120 1200 600 5.00 0.19 0.19 0.18
130 1200 600 5.42 0.18 0.18 0.17
140 1200 600 5.83 0.17 0.16 0.16
150 1200 600 6.25 0.15 0.15 0.15
160 1200 600 6.67 0.15 0.14 0.14
170 1200 600 7.08 0.14 0.14 0.13
180 1200 600 7.50 0.13 0.13 0.12
190 1200 600 7.92 0.12 0.12 0.12
200 1200 600 8.33 0.12 0.12 0.11
Thickness Length Width R-value Typical U-value Typical U-value Typical U-value
(mm) (mm) (mm) (m2k/W) on metal deck on concrete deck on timber deck
(W/m2k) (W/m2k) (W/m2k)
30 2400 1200 1.36 0.67 0.63 0.53
40 2400 1200 1.82 0.51 0.49 0.43
50 2400 1200 2.27 0.42 0.40 0.36
60 2400 1200 2.73 0.35 0.34 0.31
70 2400 1200 3.18 0.30 0.30 0.27
80 2400 1200 3.64 0.27 0.26 0.24
90 2400 1200 4.09 0.24 0.23 0.22
100 2400 1200 4.55 0.22 0.21 0.20
110 2400 1200 5.00 0.19 0.19 0.18
120 2400 1200 5.46 0.18 0.18 0.17
130 2400 1200 5.91 0.17 0.16 0.16
140 2400 1200 6.36 0.15 0.15 0.15
150 2400 1200 6.82 0.14 0.14 0.14
160 2400 1200 7.27 0.14 0.13 0.13
170 2400 1200 7.73 0.13 0.13 0.12
180 2400 1200 8.18 0.12 0.12 0.12
190 2400 1200 8.64 0.11 0.11 0.11
200 2400 1200 9.09 0.11 0.11 0.10 FOR FREE TECHNICAL ADVICE Call: 01268 597 212/213Email: [email protected]
TOPLINE TOPLINE
Insulation
2013
APPLICATIONS
• SINGLE PLY ADHERED • SINGLE PLY MECHANICAL FIX
NEW
• TORCH• ROLL AND POUR• ASPHALT• BITUMEN COMPATIBLE
SINGLE PLY
NEWWE'VE GOT IT COVERED
a tapered solution for all applications
www.ecotherm.co.uk tel: 01702 52016618 19
Cert 07/4487Cert 07/4487
FOR ROOFS
TOPLINE
FOR ROOFS
TOPLINE
Benefits
■ EcoTherm Eco-Deck is
manufactured from FSC
(Forest Stewardship Council)
certified timber ply and ZERO
ODP foam
■ EcoTherm Eco-Deck provides
roof constructions which do
not require cross ventilation
of the roof void
■ FSC certified timber OSB
grade 3 – guaranteed legal
and sustainable
■ Compatible with all built up
roofing membranes
■ Maximum insulation for
minimum thickness
■ Simple application
Dimensions
Width (mm): 1200
Length (mm): 2400
OSB thickness (mm): 9
PIR core thickness (mm): 90, 100, 110, 120, 130, 140, 150
Design considerations
These should be assessed in accordance with the BS 6399-2 1997.
Consideration should also be given to BS 5250: 2002 Code of Practice for control of condensation in buildings
and BS 6229: 2003 Code of Practice for flat roofs with continuously supported coverings. Mechanical fixings
should be specified as recommended in BRUFMA information document ID/1/2009 mechanical fixings for
rigid PIR roof boards.
Thermal conductivity
The thermal conductivity, λ value, of EcoTherm Eco-Deck insulation is typically 0.022W/mK. The OSB element
of the roof-deck has a thermal conductivity rating of 0.14W/mK. The thermal resistance ‘R’ varies with
thickness as shown in the table below.
Benefits
■ EcoTherm Eco-Taper creates
falls on flat roofs. It is
manufactured for fast and
easy application
■ Thicknesses ranging from
30-190mm, the widest range
available for a single layered
taper system
■ Mitred boards for both hips
and valleys available
■ EcoTherm Eco-Taper is
ZERO ODP
■ EcoTherm Eco-Taper provides
warm-roof constructions
Dimensions
Width (mm): 1200
Length (mm): 1200
Design considerations
These should be assessed in accordance with the BS 6399-2 1997.
Consideration should also be given to BS 5250: 2002 Code of Practice for control of condensation in
buildings and BS 6229: 2003 Code of Practice for flat roofs with continuously supported coverings.
Mechanical fixings should be specified as recommended in BRUFMA information document ID/1/2009
mechanical fixings for rigid PIR roof boards. In order to determine the U-value of a tapered scheme,
please refer to Annex-C of BS EN 6946: 2007.
Thermal insulation for flat roofs
Description: 9mm OSB grade 3 faced PIR thermal insulation tough,
structural, pre-insulated foil backed roof decking
Purpose: Insulation and decking for flat roof applications
Thermal insulation for tapered roofing schemes
Description: PIR core for single ply. Cut-to-fall for pond-free flat roofs.
Available in 1:60 falls and 1:80 falls
Purpose: For use with single ply or built-up felt roofs
Eco-TaperEco-Deck
FSC Certificate No. C806092FSC.COC.01.2006 Certification Code: CU.COC.806092
1996 Forest Stewardship Council A.C.
By buying products with the FSC label you are supporting the growth of responsible forest managementworldwide
CU-COC-806092
The profile of the boards are as follows:
Non foil (mm) Foil (mm)
1:60 1:80 1:60 1:80
A = 30-50 30-45 A = 30-50 30-45
B = 50-70 45-60 B = 50-70 45-60
C = 70-90 60-75 C = 70-90 60-75
D = 90-110 75-90 D = 90-110 75-90
E = 110-130 90-105
F = 130-150 105-120
G = 150-170 –
H = 170-190 – Thickness Length Width R-value Typical U-value
(mm) (mm) (mm) (m2k/W) (W/m2k)
99 o/all 2400 1200 4.16 0.22
109 o/all 2400 1200 4.62 0.20
119 o/all 2400 1200 5.07 0.18
129 o/all 2400 1200 5.53 0.17
139 o/all 2400 1200 5.98 0.16
149 o/all 2400 1200 6.44 0.15
159 o/all 2400 1200 6.89 0.14
TOPLINE TOPLINE
Insulation
2013
superior rigid insulation
EcoTherm Insulation (UK) Ltd.Harvey Road, Burnt Mills Ind. Est., Basildon, Essex, SS13 1QJ tel: +44 (0) 1702 520166 fax: +44 (0) 1702 420636 www.ecotherm.co.uk email: [email protected] consult EcoTherm for details of BBA certificate numbers for specific products
EcoTherm Insulation (UK) Ltd. is registered in England No. 1873816
EcoTherm Insulation offers a wide range of services for
all architects, house builders, housing associations,
specifiers, suppliers and end users.
The services are free of charge on both new build and
refurbishment projects. Our technical support team are
continually updating their knowledge on building trends,
construction methods and the ongoing development of
building materials and Building Regulations.
To contact Technical Services
Tel: +44 (0)1702 520166
Fax: +44 (0)1702 420636
or E-Mail: [email protected]
EcoTherm Technical Support is open
8:30 – 17:00 Monday to Friday
EcoTherm Technical Support
Services available
■ U-value calculations to show compliance with current Building
Regulations for floors, walls and roofs (both flat and pitched)
supported by a detailed report
■ Condensation risk analyses are available on request, again
supported by a detailed report
■ Site visits; our technical team is available to provide on-site
assistance and advice where necessary
■ Full site surveys can be carried out for tapered roof projects
■ Advice on product selection and product data for all EcoTherm
Insulation products
■ General application and fixing on all applications
■ Specification advice
■ Impartial product advice on associated products and proposed
system elements