Page 2: Wireless Thermostats 230v and Battery Operated Quick Set

1 x Quick Set-up Guide JGSTATW2

4x AAA Batteries

JGSTATW1Fixing screws

Box contents:

Contents

Quick Set-up Guide:• Box contents• Introduction• Product compliance• Terminal connections • Coordinator set-up• JGBR set-up• Identifying the Wiring Centre• PRT quick set-up• HWT quick set-up

Icons used in this guide:

Safety

Important info

For latest PDF Quick Set-up Guide andfull Instruction Manual please go tospeedfitUFH.co.uk

speedfitUFH.co.uk

For models:

JGSTATW2WJGSTATW2BJGSTATW1WJGSTATW1B

Quick Set-up Guide

Wireless Thermostats230v and Battery Operated

03speedfitUFH.co.uk

Page 3: Wireless Thermostats 230v and Battery Operated Quick Set

04 JGSTATW1/W2 Quick Set-up Guide

Introduction. Thank you for purchasingone of our Speedfit Aura WirelessThermostat models. It must be used withthe JGCO Wireless Coordinator. TheWireless Coordinator allows communicationwith other devices in the Aura Wirelesssystem range including wiring centre,Wireless boiler receiver and Wireless TRV.

Product Compliance. Theseproducts are CE compliant andmeets the following EuropeanDirectives:

RoHS2: 2011/65/EU

RED: 2014/30/EU

Declaration of conformity availableat saluslegal.com

Safety Information. Use inaccordance with the regulations.The JG Aura JGSTATW1/W2 isto be used for room control ofheating and hot water systemsinside buildings.

JGWCW

JGTRV

JGSTATW1/W2

JGCO

Product compliance & safety information

We hope you enjoythis product...JGBR

Page 4: Wireless Thermostats 230v and Battery Operated Quick Set

Product compliance & safety information

Emergency. Switch off thevoltage to the individualthermostat, wiring centre orcomplete system.

Sources of danger. Thethermostat must be disconnectedfrom mains supply beforeremoving the cover.

Installer parameter settings.JG Aura wireless thermostats areequipped with an Installer Parametersection (see website). This must onlybe entered by the installer or acompetent person. Changing theseparameters can have a seriouseffect on your heating system.

230 ACWarning. This product must befitted by a competent person.Installation must comply with theguidance, standards andregulations applicable to thelocation where the product isinstalled. Failure to comply with therequirements of the relevantguidance, standards andregulations could lead toprosecution, injury or death.

These instructions are applicable to theAura models stated on the front cover ofthis Instruction Manual only.

Warning. Always isolate the ACMains supply before installing orworking on any components thatrequire 230v AC 50Hz supply.

05speedfitUFH.co.uk

Page 5: Wireless Thermostats 230v and Battery Operated Quick Set

Rear of unit Power Terminals 230v AC.Used for supplying power to theunit. 230v supply can be sourcedfrom the wiring centre or anyconvenient 3amp fused supply.

Probe / Hot Water CylinderTerminals. Can be used forexternal Air or Floor probe whenconfigured as thermostat. Canalso be used for Cylinderthermostat connection whenconfigured as a Timer.

Understanding your terminal connections

Terminal connections (JGSTATW2) - 230v powered

2

1

12

06 JGSTATW1/W2 Quick Set-up Guide

230VACVS10BRF

Page 6: Wireless Thermostats 230v and Battery Operated Quick Set

07speedfitUFH.co.uk

Rear of unit

Sensor Terminals. Can be used for an external Airor Floor sensor when configuredas thermostat. Can also be usedfor Cylinder thermostat whenconfigured for HW.

Understanding your terminal connections

Terminal connections (JGSTATW1)

1

1

S1 - S2

Page 7: Wireless Thermostats 230v and Battery Operated Quick Set

To commence system installation, press and hold the button for 5 seconds. The buttonwill start to flash red indicating that the Zigbee network is ready to accept JG Aura devices.

For full Coordinator instructions please see seperate literature or go on line tospeedfitUFH.co.uk

Coordinator set-up

08 JGSTATW1/W2 Quick Set-up Guide

Page 8: Wireless Thermostats 230v and Battery Operated Quick Set

After setting up, the Coordinator will assign theWiring Centre a number. This is because morethan 1 Wiring Centre may be used on a project.Pressing the network button will illuminate therelevant number. The example shown is forWiring Centre 1. If 1 and 2 are lit it would beWiring Centre 2.

The JGBR default setting is RX1 (Wireless Boiler Receiver). In thismode, the JGBR will switch on the boiler in response to a call for heat.

To set as a wireless receiver, switch to RX2. The wireless receiver willbe paired to just one chosen thermostat on the network. Thisthermostat will switch the wireless receiver when there is a call for heat.

JGBR set-up - Wireless Boiler Receiver or Wireless Receiver

Identifying the Wiring Centre

09speedfitUFH.co.uk

Page 9: Wireless Thermostats 230v and Battery Operated Quick Set

Programmable Room Thermostat paired withWireless Wiring Centre

1 2

3

Start up screen as shown. Press CONFIRM

Prior to pairing refer to Coordinator start up on page 8.

Press CONFIRM

4

No action required.

icon flashing to request the number of theWiring Centre you wish to pair with (see IdentifyingWiring Centre - page 9). Use and to selectthe required number. Press CONFIRM

10 JGSTATW1/W2 Quick Set-up Guide

Page 10: Wireless Thermostats 230v and Battery Operated Quick Set

5 6

7

requesting group number. No actionneeded in this instance. Press CONFIRM

Zone number flashing. Using the and toset the wiring centre zone you want the thermostatto control. Press CONFIRM

Thermostat returns to home screen and the pairing is finished.Testing: Set thermostat to high temperature and wait for a call forheat. Check that the thermostat is communicating with the correctzone on the paired wiring centre.

11speedfitUFH.co.uk

Page 11: Wireless Thermostats 230v and Battery Operated Quick Set

Programmable Room Thermostat paired withWireless TRV

1 2

3

From start up screen press . Screen will scroll to .

No action required.

4

Press CONFIRM

Press CONFIRM

Prior to pairing refer to Coordinator start up on page 8.

2

12 JGSTATW1/W2 Quick Set-up Guide

Page 12: Wireless Thermostats 230v and Battery Operated Quick Set

5

7

6

8

Thermostat returns to home screen. Testing: Set tocall for heat. Check TRV’s are opening and BoilerReceiver is receiving the signal. Turn down thethermostat and check TRV’s shut and boiler receiverturns off.

Next press arrow on thermostat to start pairingprocess. Do not press Confirm as it will abortthe pairing process and user will have to start again.

Press Pairing Button on TRV(s) for 10seconds until pairing light on the TRV startsto flash. Maximum of 6 TRV’s can be pairedat the same time.

If thermostat only finds 1 to 5 TRV’s it willcontinue to search until user presses Confirm

. If the maximum 6 TRV’s are found thethermostat will automatically finish pairingand return to the home screen. 13speedfitUFH.co.uk

Page 13: Wireless Thermostats 230v and Battery Operated Quick Set

Programmable Room Thermostat paired with WirelessBoiler Receiver (RX1)

1 2

3

Start up screen as shown. Press and holdbottom 3 buttons until next screen isshown.

Press to scroll to .

4

Press CONFIRM

Press CONFIRM

2

Prior to pairing refer to Coordinator start up on page 8.

14 JGSTATW1/W2 Quick Set-up Guide

Note: See page7 for setting ofJGBR to RX1.

Page 14: Wireless Thermostats 230v and Battery Operated Quick Set

5 6

7

No action required.

Thermostat returns to home screen. Testing: Set thermostat to hightemperature and wait for a call for heat. Check the Wireless BoilerReceiver is receiving the signal and switching on and off.

Press CONFIRM

15speedfitUFH.co.uk

Page 15: Wireless Thermostats 230v and Battery Operated Quick Set

4

Press CONFIRM

Programmable Room Thermostat paired with WirelessReceiver (RX2)

1 2

3

Press to scroll to .

Press CONFIRM

Prior to pairing refer to Coordinator start up on page 8.

Start up screen as shown. Press and holdbottom 3 buttons until next screen isshown.

2

16 JGSTATW1/W2 Quick Set-up Guide

Note: See page7 for setting ofJGBR to RX2.

Page 16: Wireless Thermostats 230v and Battery Operated Quick Set

5 6

No action required.

7

Thermostat returns to home screen. Testing: Set thermostat to hightemperature and wait for a call for heat. Check the Receiver is receivingthe signal and switching on and off. If there is also a boiler receiver fittedto the network check that this is responding.

Press CONFIRM

17speedfitUFH.co.uk

Page 17: Wireless Thermostats 230v and Battery Operated Quick Set

Hot Water Timer paired with Wiring Centre

Press to scroll to Hot Water Timerscreen

1 2

3

Press CONFIRM

4

Press CONFIRM

Start up screen as shown. Hold bottom3 buttons to scroll to screen .

Prior to pairing refer to Coordinator start up on page 8.

2

18 JGSTATW1/W2 Quick Set-up Guide

Page 18: Wireless Thermostats 230v and Battery Operated Quick Set

5 6

7 8

Hot Water Timer displays home screen. Testing: Set timer to [ON] and check that HotWater Timer LED is lit on wiring centre.

Note: Hot WaterTimer willautomaticallyjoin Group 1.

No action needed. Press CONFIRM

icon flashing to request thenumber of the Wiring Centre to pair with(see Identifying Wiring Centre - page 9). Use and to select the requirednumber. Press CONFIRM 19speedfitUFH.co.uk

Page 19: Wireless Thermostats 230v and Battery Operated Quick Set

John Guest Speedfit LimitedHorton Road, West Drayton, Middlesex UB7 8JL, England.

Tel: 01895 449233 Fax: 01895 420321speedfitUFH.co.ukTechnical Help Desk: 01895 425333

,

The above namestyles are all trademarks of John Guest International Limited.

© John Guest International Limited 2016. All rights reserved. Z2105/458/0716

and