WIN-PAK VISTA INTEGRATION SUPPORTED FEATURES  Alarm Monitoring  Controlling Vista panel from Control Map/Floor Plan o Partition Arm/Disarm o Zone Bypass/Unbypass o Output On/Off  Virtual Keypad o Send key-Strokes o Display Update  Command File Support  Video Pop-up on Vista Alarms  Operator Action Report INDEX Section1: Vista Panel Programming For Home Automation Protocol  A. Equipments Required B. Connections For Home/Facility Automation Control C. Summary of programming commands D. Programming for the ADEMCO 4100 SM Procedure E. Configurations Section2: Vista Configuration in WIN-PAK  A. Installation Instructions B. Add Comm Server C. Add HA Port D. Add Vista Panel E. Configure Control Map F. Configure Floor Plan G. Vista Command File Support H. Virtual Keypad I. Operator Action Report J. Vista Action Group and Action Messages K. Vista Monitoring and Control

Upload: duybak

Post on 02-Jun-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 1/13

WIN-PAK VISTA INTEGRATION

SUPPORTED FEATURES

  Alarm Monitoring•  Controlling Vista panel from Control Map/Floor Plan

o  Partition Arm/Disarmo  Zone Bypass/Unbypasso  Output On/Off

•  Virtual Keypado  Send key-Strokeso  Display Update

•  Command File Support

•  Video Pop-up on Vista Alarms

•  Operator Action Report

INDEX

Section1: Vista Panel Programming For Home Automation Protocol A. Equipments RequiredB. Connections For Home/Facility Automation ControlC. Summary of programming commandsD. Programming for the ADEMCO 4100 SM ProcedureE. Configurations

Section2: Vista Configuration in WIN-PAK A. Installation Instructions

B. Add Comm ServerC. Add HA PortD. Add Vista PanelE. Configure Control MapF. Configure Floor PlanG. Vista Command File SupportH. Virtual KeypadI. Operator Action ReportJ. Vista Action Group and Action MessagesK. Vista Monitoring and Control

Page 2: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 2/13

Section1. Vista Panel Programming For Home Automation Protocol

 A. Equipment Required

•  Vista 128/250 FBP - Revision 2.0 or higher

•   ADEMCO 4100SM Serial Interface Module 

•  Serial to IP converter  

Communication settings should be 1200-baud, 8 data bits, no parity, and one stop bit.

B. Connections for Home/Facility Automation Control

         1

         2

         3

         4

         5

         6

         7

         8

         9

J2 CONNECTOR

BLACK

GREY

YELLOW

RED

GREEN

BROWN

BLUE

VIOLET

4142TR CABLE (SUPPLIED WITH 4100SM)

4100SMSERIALMODULE

+ PWR

- (GND)

RXD

NOT USED

NOT USED

TXD

NOT USED

DTR

BLUE WHITE

TOAUTOMATION

EQUIPMENT(RS232 INTERFACE)

RED

4100SM-015-V1

AUX PWR.

AUX GND.

         1         1

         1         2

CONTROL PANEL

WHITE

8

7

6

5

4

3

2

1

 

C. Summary of Programming commands

•  Find out the installer code. For 128/250 FBP it is 5140 by default.

•  To set defaults, enter *97o  1 to load ADEMCO defaults; 2 to load ADT defaults; 0 to exit without changing

programming•  *96 is used to set engineering defaults.

o  If this is performed then you must do a *97 to set standard defaults.

•  To enter into program modeo  Enter installer code + [8] + [0]+ [0] +[0]o  Installer code can be modified *00 option once entered into program mode.o  Installer code must be provided in WIN-PAK from HA port page. It will be used to

perform Panel Reset from WIN-PAK.

•  To change to next page of program fields, press *94

Page 3: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 3/13

o  Press *94 to move to 2nd page, (fields 1*01 – 1*76)

  Press *99 to move back to 1st pageo  Press *94 to move to 3rd page, (fields 2*00 – 2*88)

  Press *99 to move back to 2nd pageo  Press *94 to move to 4th page, (fields 3*00 – 3*85)

  Press *99 to move back to 3rd page

•  To return to previous fields, press *99

Turn off if unused, 974 and 975 alarms - optional

•  Log in with installer code

•  *93 is used to set the alarm functions and prompts for “Zone Prog” press 1 for Yeso  “Set to Confirm” press 1 for Yeso  “Enter Zone No” press 974*o  Press * until you see “974 Zone Type – NO RESPONSE” change from 19 to 00o  Press * until you see “Enter Zone No – 000 = Quit 975” press 000* to Quit or

continue by pressing * to change 975o  Press * until you see “”975 Zone Type – NO RESPONSE” change from 19 to 00o  Press * until you see “Enter Zone No – 000 = Quit 976” press 000* to Quito  “Quit Menu Mode” press 1 for Yeso  *99 until you exit the programming mode

D. Programming for the ADEMCO 4100 SM Procedure

•  0*05 System Notify Evento  Enter 1 to view all zone faults/restores.

•  0*14 Trigger on RS232 inputo  Enter 1 for Home Facility Automation Control

•  0*70 Enable event log typeo  Enter 1.1.1.1.1 for all 5 types

•  0*79 Zone Type Restore Enableo  Enter 1.1.1.1.1.1.1.1 for 1-8 zone types

•  1*78 Extended Home Control Event Reporto  Enter 1

•  1*79 Home Control Event Report Typeso  Enter 1.1.1.1.1.1 for 1-6 zone types

•  2*30 Pager Installedo  Enter 0

•  3*19 Enable J2 Header Printer Porto  Enter 1 for Home Automation Control

E. Configurations

•  Number of partitions can enabled from 2*00 programming optiono  Create Partition ADVs accordingly in WIN-PAK. Refer to section2

•  Zone information can be configured from programming options given in 0*93o  Create Zone ADVs accordingly in WIN-PAK. Refer to section2.

•  Output information can be configured from programming options given in 0*93

Page 4: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 4/13

o  Create output ADVs accordingly in WIN-PAK. Refer to section2.

•  Assign keypad to partition-1.

•  Create a Master user that should be able to Arm/Disarm partitions, Bypass/Unbypasszones, etc. Assign all the partitions enabled.

o  Tip: For adding user 002 with user code 1234, enter [5140][8][002][1234]o  Master user code must be provided in WIN-PAK from HA Port page. It will used to

perform Arm/Disarm/Bypass/Unbypass commands from WIN-PAK.

Section2: Vista Configuration in WIN-PAK

 A. Install WIN-PAK - The Vista option is enabled based on the CDKey code number.

B. Add Communication Server – Go to ‘Device Map’ from the top-level menu ‘Configuration’

Page 5: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 5/13

C. Add Vista Panel Port (Home Automation)a. Enter name for the Vista Port Configuration and Add ADV.b. The Loop Verification Interval is coded not to go below 40 to ensure proper Vista

operation.c. Select communication COM port/TCP from next page. Please enter Master code and

installer code in the current page.

d. Finish

Page 6: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 6/13

 

Page 7: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 7/13

 D. Add a Vista panel

a. Select ‘Add New Vista Panel’ from the pop-up menu on Vista Panel Portb. Enter name and add ADVc. Add Vista Partition ADVs

i. Each partition ADV maps to a particular partition defined at the Vista panel.

d. Add Vista Zones ADVsi. Each zone ADV maps to a particular zone defined at the Vista panelii. Each zone can be assigned a Type from ‘Zone Type’ Combo box. ‘Zone Type’

shall be used to display zones of particular type using unique graphical icon inControl Map.

iii. Each zone must be assigned to a partition from Partition Name Combo box.e. Add Vista Output ADV's

i. Each Output ADV maps to a particular output defined at the Vista panelf. Finish

Page 8: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 8/13

 

Page 9: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 9/13

 

Page 10: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 10/13

E. Configure Control Map – Define Control Map from top-level menu Configuration -> Define->Control Area.

a. Add Vista device(s) to an appropriate branch. Filters are provided in ‘Add Devices’dialog box.

F. Configure Floor Plan – Define Floor Plan from top-level menu ‘Configuration’

Page 11: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 11/13

Currently Floor Plan representations for Vista devices are same as Galaxy devices. Tool Tipover the icon exhibits the correct type.

G. Vista Command File Support – Vista Command Files can be configured from top-level menuConfiguration->Command Files

H. Virtual Keypad can be launched from selected partition node in Control Map. A delay of up to6 seconds may be seen before the Virtual Keypad is updated. 2 seconds is typical. If noresponse is seen with in 6 seconds, you may need to re-enter the key pad strokes. Closing

and re-launching the Virtual Keypad will force a refresh of the display (less than 2 seconds).

Page 12: Winpak Vista Integration Help

8/10/2019 Winpak Vista Integration Help

http://slidepdf.com/reader/full/winpak-vista-integration-help 12/13

 I. Operator Action Report displays the summary of action taken on Vista Devices.

J. Vista Action Groups and Action Messages: Digital Video Camera and Command Files can beassociated with Vista actions.

K. Monitoring and Control from Alarm View, Control Map and Floor Plan