why acoustic sand detectors don’t work? acoustic sand detectors ... alarms we had no choice but to...

25
Why Acoustic Sand Detectors don’t work?

Upload: dangminh

Post on 28-Mar-2018

219 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Why Acoustic Sand Detectors

don’t work?

Page 2: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

“The well is shut-in

yet we keep getting

indications of sand

production!”

Operator issues #1

Page 3: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

“ We know we are

producing sand as

we keep filling up

our separator but

the sand detector

shows zero sand

production.”

Operator issues #2

Page 4: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

“The CRO’s were

getting flooded

with so many sand

alarms we had no

choice but to turn

the system off”

Operator issues #3

Page 5: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

“Why is it that for many operators

their acoustic monitoring systems

simply don’t work”

Why acoustic detectors don’t work

Page 6: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Detector fundamentals

• Passive microphone

transducer

• Detects noise of particles

impacting on pipe wall

• Also detects flow noise

and mechanical noise

Page 7: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

• Filter used to ensure

noise is predominantly

due to sand impacts.

Filter

• Not possible to

completely isolate sand

noise

Page 8: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Sand Rate

• Quantify each wells sand

production

• Predict sand deposition in

vessels

• Estimate erosion

Page 9: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Calibration

Real time process data

• Flow rates: Oil, Gas, Water

• Velocity

• Pressure & Temperature

• Static Inputs

Page 10: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Background noise / Zero

• Flow well at different rates

Background noise curve

y = 3x3 - 40x

2 + 533x + 2000

0

2000

4000

6000

8000

10000

12000

0 2 4 6 8 10 12 14 16

velocity [m/s]

sig

nal [1

00n

V]

Velocity Signal [100nV]

0 m/s 2000

5 m/s 4 000

10 m/s 6 000

15 m/s 10 000

• Establish background

noise at each rate

• Determine background

noise curve / zero values

Page 11: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Sand noise / Step

• Flow well at different rates

• Inject known quantities of

sand at each rate

• Determine sand curve /

step values

Sand curve [1g/s]

y = 11x3 - 240x

2 + 3533x - 0

0

5000

10000

15000

20000

25000

30000

35000

40000

0 2 4 6 8 10 12 14 16

velocity [m/s]

sig

nal [1

00n

V]

Velocity Signal [100nV]

0 m/s 0

5 m/s 13 000

10 m/s 22 000

15 m/s 35 000

Page 12: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Sand Rate

• Calculate sand rate

Production availability

Accurate particle sampling data

Raw data – Background noise

Sand Noise Sand rate =

Page 13: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

y = 3x3 - 40x2 + 533x + 2000

0

2000

4000

6000

8000

10000

12000

0 2 4 6 8 10 12 14 16

y = 11x3 - 240x2 + 3533x - 0

0

5000

10000

15000

20000

25000

30000

35000

40000

0 2 4 6 8 10 12 14 16

Background noise curve

Sand curve for 1g/s

Velocity = 11 m/s Reading = 21 040 [100nV]

Background noise = 3*113- 40*112 + 533*11 + 2000

= 7016 [100nV]

Sand noise [1g/s] = -11*113- 240*112 + 3533*8 + 0

= 24463 [100nV]

Sandrate = Reading - Background noise

Sand noise

= 21040 - 7016

24463

= 0.57 g/s

Sand Rate – worked example

Page 14: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Re-calibration

• Every 6 – 12 months

Stable process flow

POB capacity

• Change in the well flowing

conditions

Page 15: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Sand Quantification criteria

Stable process flow

Real time process data

Accurate particle sampling data

POB capacity

Production availability

Page 16: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Raw signal interpretation

You are the

experts on your

sand production!

Page 17: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Data Interpretation

Acoustic Data – Sand Event?

Page 18: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Acoustic data & erosion probe data– Sand Event - Yes

Data Interpretation

Page 19: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Acoustic data, erosion probe data, pressure & temperature– Sand Event - Yes

Data Interpretation

Page 20: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Raw Signal

• Determine sand

producing wells

• Understand how process

operations affect sand

production

• Estimate erosion – if

used in conjunction with

sampling data.

Page 21: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Case Study

Surfactant treatment and Pressure reduction

Page 22: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Case Study (cont.)

Surfactant treatment

Platform Trip during pressure reduction

Well cycled

Page 23: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Case Study (cont.)

1. Well flowing normally

2. Well cycled closed for 9 hours

3. Noise signal consistent with sand production 4. Well begins to ‘clean-up’

Page 24: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

SGA – Case Study (cont.)

Outcome: Surfactant treatment successful

Staged pressure reduction successful

! Sand production following well start-ups

! Requirement for ‘hard’ bean-up

Page 25: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000

Sand Monitoring Services

http://www.sand-monitoring.co.uk

Questions?