whole blood assay analysis of ......for their contributions towards the completion of the research...
TRANSCRIPT
!
WHOLE BLOOD ASSAY ANALYSIS OF
IMMUNOSTIMULATORY CONSTITUENTS IN
ENVIRONMENTAL PARTICULATE MATTER
by Jesse Paul Negherbon
A dissertation submitted to Johns Hopkins University in conformity with the requirements for the degree of Doctor of Philosophy
Baltimore, Maryland January, 2015
© 2015 Jesse Negherbon All Rights Reserved
ii
Abstract
The respiratory system is continuously exposed to particulate matter (PM)
through the inhalation of polluted air. The composition of this PM includes an array of
hazardous constituents derived from anthropogenic (e.g. – combustion) and biological
sources (biogenic). A fraction of these biogenic agents are non-infectious microbial
components that are often capable of engaging innate immune defense mechanisms and
stimulating the release of conserved inflammatory mediators. Thus, this biogenic fraction
of PM carries a unique capacity to provoke adverse respiratory inflammation in the
absence of an infectious challenge or overt physical injury. Accordingly, an increasing
epidemiologic evidence-base associates exposure to biogenic PM with the development
(and severity) of non-infectious respiratory disorders, such as chronic bronchitis and
obstructive lung disease.
However, the integrative methods necessary to evaluate the pro-inflammatory
potential of the full matrix of biogenic PM are absent from customary suite of exposure
assessment tools. Instead, conventional practice relies on the measurement of individual
classes of agents (e.g. – endotoxins) as proxies of pro-inflammatory hazard. This strategy
is partly limited by the sheer diversity of stimuli in the environment. The research
presented in this dissertation investigates the pro-inflammatory immune responses to PM
exposures using novel human whole blood assay (WBA) methods. The human whole
blood system carries an extensive array of innate immune defense mechanisms, displays
exquisite sensitivity to biologically relevant stimuli, and is amenable to ex vivo
stimulation with complex mixtures of agents.
iii
This document comprehensively reviews the applicability of the WBA as an
exposure assessment tool, and presents two studies in which pro-inflammatory signals of
PM were assessed via WBA. The first study used cryopreserved human whole blood to
investigate the pro-inflammatory potential of respirable, thoracic, and inhalable PM from
broiler poultry housing, where PM is heavily burdened with microbial components. The
second study used fresh whole blood from asthmatic and non-asthmatic Peruvian children
to evaluate innate immune responses to traffic PM, which has been associated the
exacerbation of asthma symptoms. Taken together, this body of research demonstrates
the potential of the human WBA to detect hazardous biogenic components in PM, and
characterize individual immunologic responses to these complex stimuli.
Thesis Advisor: Patrick N. Breysse, PhD
Thesis Readers: Alan Scott, PhD
Thomas Hartung, MD, PhD
Nadia Hansel, MD, MPH
iv
Acknowledgements
The following institutions, research centers, and individuals are acknowledged
for their contributions towards the completion of the research in this dissertation:
I am thankful for the support of my thesis committee, including Pat Breysse
(mentor and primary academic advisor), Thomas Hartung (co-mentor), Alan Scott (chair
of my dissertation committee), and Nadia Hansel. Their time, guidance, and patience
throughout the process were appreciated and allowed me develop the knowledge base
necessary to conduct this work and evolve as a researcher. I would also like to
acknowledge the efforts of Peter Lees, D’Ann Williams, Christine Torrey, Jana Mihalic,
Tim Green, Ana Rule, and the research group from the Johns Hopkins Center for
Alternatives to Animal Testing, who provided invaluable assistance and comic relief
throughout my time at Johns Hopkins.
My education and research here could not have been completed without the
financial support of the Johns Hopkins Education and Research Center for Occupational
Safety and Health, who provided both a National Institute for Occupational Safety &
Health (NIOSH) training grant program and an additional NIOSH Pilot Project grant,
which supplemented the costs of my education and research. I am also thankful for our
collaboration with Dr. Eric Benson and the University of Delaware Department Animal
and Food Sciences, who provided access to their animal facilities for field sampling and
insight into the industrial broiler poultry and dairy cattle industries.
I am continually grateful for the mentorship, guidance, and friendship of Bill
Schnabel, Francis Vanek, and Dan Sterley, who were my respective mentors at the
University of Alaska Anchorage, Cornell University, and CH2M Hill. Their energy,
v
enthusiasm, and confidence in my abilities were critical factors in my decision to pursue
a doctoral education and engage challenges beyond engineering. Lastly, I am continually
appreciative of the support of my brother, Logan, and my parents, Paul and Kelly, who
have always managed to keep me grounded and determined. It has been an adventure for
all of us, so far, and I am immensely fortunate to have had such an outstanding family to
accompany me through it.
vi
Table of Contents !Abstract ii
Acknowledgements iv
Chapter 1. 1
1.1. Introduction 2
1.2. Research Aims 7
1.2.1. Project 1 7
1.2.2. Project 2 8
Chapter 2. Methods for Assessing the Pro-Inflammatory Potential
of Biogenic Particulate Matter 10
2.1. Abstract 11
2.2. Introduction and Background 12
2.3. Pro-inflammatory Potential of Biogenic PM Constituents 14
2.3.1. Bacterial Endotoxins 15
2.3.2. Non-Endotoxin Stimuli 20
2.4. Endotoxin and Non-Endotoxin Testing Methods 24
2.4.1. Limulus Amebocyte Lysate (LAL) Test 24
2.4.2. Whole Blood Assay (WBA) Methods 27
2.5. Discussion 36
2.6. Conclusion 39
Chapter 3. Whole Blood Assay Evaluation of Pro-Inflammatory
Stimuli in Broiler Poultry House Particulate Matter 40
3.1. Abstract 41
vii
3.2. Introduction 42
3.3. Materials and Methods 46
3.3.1. Sampling Environments and Ethics Approval 46
3.3.2. PM Sampling 50
3.3.3. Preparation of PM Extracts 51
3.3.4. Endotoxin Testing 52
3.3.5. Whole Blood Collection & Cryopreservation 53
3.3.6. Whole Blood Assay 54
3.3.7. Cytokine Measurement 55
3.3.8. Statistical Analysis 56
3.4. Results 58
3.4.1. Environmental PM Concentrations 58
3.4.2. Endotoxin & Equivalent Endotoxin Stimuli per Unit Mass of PM 63
3.4.3. WBA Response to Particle-free Extracts 65
3.4.4. Endotoxin-inhibition Tests 67
3.5. Discussion 69
3.6. Conclusions 77
Chapter 4. Pro-Inflammatory Effects of Traffic PM on Whole
Blood Responses of Asthmatic Peruvian Children 78
4.1. Abstract 79
4.2. Introduction 80
4.3. Materials and Methods 84
4.3.1. Ethics Statement 84
viii
4.3.2. Study Site & Population 84
4.3.3. PM Sampling 87
4.3.4. Air Filter Extraction 88
4.3.5. Endotoxin Analysis 88
4.3.6. Blood Collection 89
4.3.7. Whole Blood Incubation 90
4.3.8. Cytokine Analysis 91
4.3.9. Statistical Analysis 91
4.4. Results 93
4.4.1. Environmental Concentrations of PM, Black Carbon, & Endotoxin 93
4.4.2. Study Population Characteristics 95
4.4.3. Differential Blood Cell Counts 95
4.4.4. WBA Cytokine Response 97
4.5. Discussion 101
4.6. Conclusions 108
Chapter 5 109
5.1 Summary 110
5.1.1. Broiler Poultry House PM 110
5.1.2. Traffic PM & Asthma 112
References 114
Curriculum Vitae 146
ix
List of Tables
Table 2.1. LAL and WBA testing considerations 25
Table 2.2. List of published studies using WBA methods for analysis
of PM samples 28
Table 2.2. (continued) List of published studies using WBA methods
for analysis of PM samples 29
Table 3.1. Average concentrations of PM, endotoxin, and equivalent
endotoxin stimuli in the air of each sampling environment 60
Table 3.2. Pro-inflammatory signal, per unit mass PM from poultry
house, dairy barn, and urban Baltimore City environments 64
Table 3.3. Reductions in pro-inflammatory signal following inhibition
of endotoxin in PM extracts with Polymyxin B 68
Table 4.1. Ambient Respirable PM, Black Carbon, and Endotoxin 93
Table 4.2. Summary of Participant Characteristics 95
Table 4.3. Differential White Blood Cell Counts 96
Table 4.4. Correlation analysis, comparing WBA cytokine response with
concentrations of PM mass, BC, and endotoxin in ambient respirable
PM extracts 99
x
List of Figures Figure 3.1. Exterior of broiler poultry house A! 47!
Figure 3.2. Interior of Bay 1 in broiler poultry house A! 47!
Figure 3.3. Floor plan of broiler poultry house A! 48!
Figure 3.4. Floor plan of broiler poultry house B! 48!
Figure 3.5. Indoor air concentrations of PM (A), endotoxins (B), and
equivalent endotoxin stimuli (C) increase significantly for each of
the respirable, thoracic, and inhalable particle size fractions over the
42-day broiler flock growth cycle.! 62!
Figure 3.6. Endotoxin content per unit mass of PM in Poultry House B
varies over the growth cycle of the flock.! 65
Figure 3.7. Insoluble particles contribute to pro-inflammatory potential
of poultry and dairy PM extracts.! 66!
Figure 4.1. Study area limits in the neighborhood of Pampas de San Juan
de Miraflores in Lima, Peru! 85!
Figure 4.2. Respirable and PM2.5 fractions of ambient PM and BC in the
study area.! 94!
Figure 4.3. No difference between asthmatic and non-asthmatic participants
in WBA IL-1β response to endotoxin (Panels A & B) or PM2.5 (Panel C)! 97!
Figure 4.4. IL-1β responses to WBA stimulation with PM 2.5 are reduced
for study participants living within 75 meters of the study area
highway in Pampas! 98!
1
!
Chapter 1
!!!!
2
1.1. Introduction
The aims of the research presented in this dissertation are interrelated through the
common objective of quantifying the burden of pro-inflammatory constituents in
environmental particulate matter (PM). Within the field of exposure science, there is
increasing appreciation for the capacity of PM constituents to engage defense
mechanisms of the human innate immune system and provoke non-specific airway
inflammation (Cherrie et al., 2013; Poole & Romberger, 2012). This “pro-inflammatory
potential” of PM represents a complex non-infectious respiratory hazard and has drawn
focus towards the immunostimulatory properties of biologically derived (i.e. - biogenic)
agents (Liebers et al., 2008; Rylander, 2002).
Many constituents in the biogenic fraction of PM may originate from microbial
populations (Douwes et al., 2003). Among these microbial components, Gram-negative
bacterial endotoxins are known to be a potent class of pro-inflammatory agents and are
the most extensively studied of the biogenic contaminants in PM (Duquenne et al, 2013).
However, they are just one of a broad array of microbial constituents that may carry such
pro-inflammatory potential. The immunologic recognition of this stimuli results in a
complex series of events, which include the release of inflammatory mediators (e.g. –
cytokines, chemokines, antimicrobial proteins), recruitment of inflammatory immune
cells (e.g. – monocytes, neutrophils), and activation of resident immune cells (Turvey &
Broide, 2010).
Although the natural intent of this inflammatory cascade is aimed at combatting
pathogenic infection and resolving injury, the inhalation of non-infectious biogenic PM
may trigger unwarranted respiratory inflammation (Si-Tahar et al., 2009). Acute
3
respiratory exposures to biogenic PM are associated with both acute and chronic
respiratory health effects that range from reversible lung function decline to chronic
obstructive pulmonary disease (COPD) (Lai & Christiani, 2013; Eduard et al., 2009;
Donham et al., 2000). The accurate evaluation for the pro-inflammatory hazards of
environmental PM remains a formidable challenge and a principal priority for exposure
scientists and the greater public health community (HEI, 2010; Pope & Dockery, 2006;
Brunekreef & Holgate, 2002).
The research in this dissertation was partly motivated by the methodological
limitations that are associated with the analysis of pro-inflammatory PM constituents.
Chapter 2 of this document provides an overview of these issues and details the purpose
and need for integrated testing methods. The research presented in this dissertation
focused on the use of testing approaches that are biologically relevant and model the
kinetics of the acute phase inflammatory response following stimulation of the human
innate immune system. Human whole blood assay (WBA) methods were chosen as they
represent novel in vitro approaches in exposure assessment, and allow for complex
mixtures of environmental stimuli to be evaluated in a robust immunologic system.
This dissertation includes two field studies in which human WBA methods were
used to assess exposure to environmental PM. The first of these studies is presented in
Chapter 3, and is an evaluation for the pro-inflammatory hazards of PM from broiler
poultry houses. Poultry house PM is generated almost entirely by the re-suspension of
litter containing poultry feces, feeds, bedding materials, feathers and dander (Donham et
al., 2000). An abundance of microbial sources contribute to the biogenic composition of
this PM, and poultry workers are routinely exposed to high concentrations of aerosolized
4
particles during their work shifts (Lawniczek-Walczyk et al., 2013; Viegas et al., 2012;
Dumas et al., 2011). Inhalation of poultry house PM often results in airway inflammation
(Rylander & Carvalheiro, 2006). While endotoxin and non-endotoxin stimuli are thought
to mediate this inflammatory activity, the aggregate pro-inflammatory potential of
poultry PM is not well understood.
Our investigation into occupational exposures to broiler poultry PM was also
motivated by the significant role that the broiler industry holds in the agricultural
economy of the Delmarva region, which has one of the highest densities of industrial
broiler houses in the United States (US). Poultry production from Delmarva accounts for
over five percent of the nine billion broilers that are raised each year in the United States
(US) (USDA, 2013). This is a significant volume of production and the long-term
sustainability of this industry is partially reliant on the health and safety of its workers,
who endure a variety of occupational hazards.
Broiler poultry flocks are housed in facilities that raise high densities of birds to
market weight over seven week cycles (MacDonald, 2014). The daily care for broilers is
contracted out from industrial hatcheries to small farming operations, who provide the
labor and housing facilities (Ollinger et al., 2005). While industrial broiler houses are
engineered for efficiency, and may raise flocks of 600,000 or more birds at one time, they
foster harsh working conditions (Donham, 2010). An increasing epidemiologic evidence-
base suggests that poultry workers, among other laborers in the livestock industry, are at
elevated risk for developing a variety non-infectious respiratory disorders (e.g. - chronic
bronchitis, COPD) (Eduard et al., 2009; Kirychuk et al., 2003; Donham et al., 2000).
5
The poultry PM study completed for this dissertation aimed to characterize the
burden of stimuli carried by the respirable, thoracic, and inhalable particle size fractions
of PM collected from active broiler poultry houses. We collaborated with investigators
from the University of Delaware’s Department of Animal and Food Sciences to conduct
PM sampling in two of their broiler research facilities. These houses were operated to
model conditions in full-scale industrial facilities. For purposes of comparison, PM was
sampled from an active dairy cow barn and from ambient air in urban Baltimore City.
A Limulus Amebocyte Lysate (LAL) test was used to quantify the endotoxin
content of aqueous PM extracts. The pro-inflammatory potential of this PM was also
evaluated based on the capacity of sample extracts to elicit the release of the
inflammatory cytokine Interleukin (IL)-1β in a cryopreserved human WBA. For this
testing, we pooled peripheral whole blood donations from five health individuals in order
to normalize individual immunologic differences before WBA testing. The pro-
inflammatory signal of this PM was assessed by size fraction and contrasted against PM
sampled from an active dairy cow barn and from ambient air in urban Baltimore City.
Further WBA testing was then completed to determine how much of the signal was
mediated by insoluble constituents and non-endotoxin stimuli.
The fourth chapter of this dissertation presents a study that used WBA methods to
investigate PM exposures of an entirely different nature. This research focused on the
capacity of traffic-related ambient PM to stimulate acute phase inflammation from the
immune systems of asthmatic and non-asthmatic children. Exposure to ambient PM that
is enriched with mobile source combustion constituents is known to stimulate airway
inflammation and is increasingly regarded as an environmental risk factor for asthma
6
(Delfino et al., 2013; Ghio et al., 2012; McCreanor et al., 2007). Correspondingly, the
ambient concentrations of PM are higher near major highways (HEI, 2010).
In the context of childhood asthma, increasing residential proximity to highways
has been associated with an elevated prevalence of asthma symptoms (McConnell et al.,
2006; Venn et al., 2001), decreased lung function (Holguin et al., 2007), and high rates of
allergic sensitization (Baumann et al., 2011; Morgenstern et al., 2008). However,
aeroallergens do near appear to consistently explain the hazards of this PM for asthmatics
(Miller & Peden, 2014). The capacity of this PM to provoke respiratory inflammation is
regarded as an important determinant in its potential hazard for susceptible populations
since it is capable of transporting over long distances in the environment, and depositing
in the sensitive alveolar region of the respiratory tract (Pope & Dockery, 2006).
This study recruited asthmatic and non-asthmatic children from a peri-urban
community in Lima, Peru. These participants lived in residences that were either within
75 meters (m) of a major highway in the study area, or at distances of 150 m or more
away from it. The respirable fraction of ambient PM was sampled from air in the study
area to assess concentrations of PM mass, black carbon, and endotoxin. Peripheral whole
blood was collected from asthmatic and non-asthmatic children and fresh blood was
stimulated ex vivo with endotoxin and aqueous extracts of local PM. WBA release of the
cytokine Interleukin (IL)-1β was quantified as a marker of inflammatory response.
Participant cytokine responses were assessed as a function of asthma status and the
proximity of their household to the study area highway.
7
1.2. Research Aims
The overall objective of the research in this dissertation was to evaluate the
potential of environmental PM to elicit the release of inflammatory mediators from the
human immune system. The human whole blood system was chosen as a model for this
research and the respective study hypotheses and aims are presented below.
1.2.1. Project 1: Investigate pro-inflammatory potential of PM from the indoor air of
active broiler poultry housing.
The first project in this dissertation used a WBA with cryopreserved human whole
blood (pooled from multiple healthy donors) to assess the relative immunostimulatory
potential of different particle size fractions of PM collected from three distinct
environments. The hypotheses tested for this study included:
H1: The burden of bacterial endotoxins and pro-inflammatory stimuli are
distributed evenly across the particle size distribution of poultry house PM, when
normalized to units of PM mass.
H2: The endotoxin content and proinflammatory potential of poultry house PM is
equivalent to that of PM from the indoor air of a dairy cow barn.
H3: The water soluble fraction of constituents in poultry house PM carries the full
burden of pro-inflammatory stimuli.
H4: Endotoxins exclusively mediate the proinflammatory signal in poultry house
PM.
8
The following aims were developed to address the study hypotheses:
• Collect time-integrated area samples of respirable, thoracic, and inhalable PM
from broiler poultry housing, a dairy barn, and ambient air in Baltimore City.
o Determine the mass of PM collected over the duration of sampling.
• Evaluate the endotoxin content in the water-soluble fraction of the respirable,
thoracic, and inhalable PM samples using a kinetic chromogenic LAL test.
• Prepare aqueous extracts of PM samples from each environment and
determine the capacity of each extract to elicit the release of the cytokine
Interleukin (IL)-1β from cryopreserved human whole blood, as a marker of
pro-inflammatory potential.
o Assess the pro-inflammatory potential of the PM extracts, with- and
without the water-insoluble fraction of PM constituents
o Assess the pro-inflammatory potential of the PM extract in the
presence of an endotoxin inhibitor.
1.2.2. Project 2: Evaluate the effects of traffic PM exposure on peripheral whole blood
cytokine responses from asthmatic and non-asthmatic Peruvian children.
Project 2 used a WBA to assess the variation in systemic innate immune
responses between asthmatic and non-asthmatics children. The respirable fraction of PM
was sampled from ambient air in the study area to determine concentrations of PM mass,
black carbon, and endotoxin. Fresh human whole blood from study participants was
stimulated ex vivo with a control standard endotoxin and environmental PM from the
study area. In this study, the following hypotheses were tested:
9
H1: Ambient concentrations of respirable PM and black carbon are higher in the
air within 75 meters of the study area highway, in comparison to concentrations
in the air at distances of 150 meters or more.
H2: Peripheral whole blood from asthmatic children releases greater amounts of
the cytokine IL-1β, following ex vivo stimulation with endotoxin or PM, than
whole blood from non-asthmatic children.
H3: Peripheral whole blood from children living near the study area highway (75
meters or closer) releases a greater amount of the cytokine IL-1β, following ex
vivo stimulation with endotoxin or PM, than whole blood from children living 150
meters or more from the highway.
The following aims were developed to address the study hypotheses:
• Collect 5-day time-integrated samples of respirable PM from ambient air in
the study area.
o Quantify the mass of PM collected over the duration of sampling.
o Determine the black carbon content of the respirable PM
o Evaluate the endotoxin content of the water-soluble fraction of
constituents from the respirable PM samples.
• Characterize the IL-1β cytokine response following ex vivo stimulation of
participant whole blood with endotoxin, PM2.5, and respirable PM.
• Determine leukocyte counts for each peripheral whole blood donation to
account for variations in blood monocyte counts.
10
!!!
Chapter 2
Methods for Assessing the Pro-Inflammatory Potential of
Biogenic Particulate Matter
Jesse P. Negherbon
Department of Environmental Health Sciences
Johns Hopkins Bloomberg School of Public Health
615 N. Wolfe St., Baltimore, MD 21205
Keywords: Endotoxin, Particulate Matter, Whole Blood Assay, Occupational Exposure
11
2.1. Abstract
The respiratory system is continuously exposed to environmental particulate
matter (PM), which often carries non-viable, non-infectious microbial constituents. Many
of these agents are capable of stimulating the release of acute phase inflammatory
mediators from the innate immune system. The biogenic fraction of this PM carries a
unique potential to provoke adverse airway inflammation in the absence of infectious
threat. Recurrent exposures are thought to promote the development of chronic
respiratory disease and are common in occupational settings. However, the hazards of
these biogenic PM exposures are not easily quantified and are often evaluated solely on
the basis of endotoxin testing. This single-pollutant testing strategy lacks the biologic
relevance and integrative capacity necessary to evaluate the pro-inflammatory potential
of the full PM matrix. This review summarizes the applicability of the limulus amebocyte
lysate test and human whole blood assay methods for evaluation of the pro-inflammatory
hazards of biogenic PM.
12
2.2. Introduction and Background
The respiratory system is continuously exposed to particulate matter (PM), which
is a heterogeneous mixture of constituents that may change significantly over time, and
across environments (Davidson et al., 2005). Due to the complexity of sources in the
environment, PM is capable of representing a broad range of acute and chronic health
hazards, many of which are mediated by inflammation (Ghio et al., 2012; Lai &
Christiani, 2013; Liebers et al., 2006; Pope & Dockery, 2006). The accurate evaluation of
this pro-inflammatory hazard remains a formidable challenge and a principal priority for
exposure scientists and the greater public health community (Pope & Dockery, 2013;
Anderson et al., 2012; HEI, 2010).
Customarily, the study of PM-associated health effects has focused on exposures
to anthropogenic PM constituents (i.e. - transition metals, black carbon), with emphasis
on chronic cardiopulmonary health endpoints (Dockery, 2009; Pope & Dockery, 2006;
Riedl & Diaz-Sanchez, 2005; Brunekreef & Holgate, 2002). A secondary focus has been
attributed to infectious hazards of pathogenic bioaerosol agents (e.g. - Legionella
pneumophila, Mycobacterium tuberculosis) and allergic responses to aeroallergens (e.g. -
house dust mite allergen) (Guarnieri & Balmes, 2014; Matsui, 2014; Diette et al., 2008;
Douwes et al., 2003). However, there is an emerging interest in PM constituents that
originate from biological sources and carry potential to stimulate respiratory
inflammation through non-allergic pathways (Cherrie et al., 2013; Poole & Romberger,
2012).
Environmental populations of microbes are dynamic sources of these “biogenic”
constituents, and are capable of imparting a rich mosaic of enzymes, metabolites, genetic
13
material, and residual structural components (i.e. – endotoxins, lipoproteins, fungal β-
glucans) onto the PM matrix (Douwes et al., 2003). Select classes of these microbial
motifs represent exogenous danger signals to the human immune system and are known
for their capacity to engage innate immune defense mechanisms (Kawai & Akira, 2011).
These agents serve as specific ligands to soluble and cell-bound innate immune pattern
recognition receptors (PRR) throughout the body, and have been collectively referred to
as pathogen-associated molecular patterns (PAMPs) (Takeuchi & Akira, 2010).
The immunologic recognition of PAMPs, such as bacterial endotoxins, results in a
complex series of events, which include the release of inflammatory mediators (i.e. –
cytokines, chemokines, antimicrobial proteins), recruitment of inflammatory cells (e.g. –
monocytes, neutrophils), and activation of resident immune cells (Turvey & Broide,
2010). While the natural intent of this inflammatory cascade is aimed at combatting
pathogenic infection and resolving injury, there is an increasing appreciation for the
capacity of PAMPs, among other biogenic agents, to drive adverse and unnecessary
inflammation in the absence of infectious threat or overt physical injury (Si-Tahar et al.,
2009). These biogenic agents represent a unique facet of the non-infectious respiratory
health hazards associated with environmental PM exposures. Their role in mediating
these hazards is not well understood and not easily measured.
14
2.3. Pro-inflammatory Potential of Biogenic PM Constituents
The inhalation of environmental PM results in the deposition of particles onto the
epithelial and mucosal surfaces of the respiratory tract, where they encounter a complex
immunologic interface (Heyder, 2004). These surfaces are populated with a diverse suite
of innate and adaptive immune defense mechanisms, which continuously survey for
threats from the environment and clear particles from the system (Parker & Prince, 2011).
The innate immunologic components (e.g. – alveolar macrophages, surfactant proteins) at
this interface are critical as they are calibrated to rapidly detect and respond to conserved
signals of danger (Hussell & Bell, 2014). Acute inflammatory responses to stimulation
from the environment are integral in the mitigation of pathogenic challenges, and are
inherently linked to a variety of functions that include immune cell trafficking, increased
phagocytosis, and the coordination of the adaptive immune response (Akira et al., 2006).
However, respiratory exposures to bolus or repetitive doses of biogenic PM
appear to over-stimulate or exhaust these pathways. The undue inflammation that results
from such exposure is believed to disrupt a carefully maintained state of immunologic
homeostasis in the respiratory system, resulting in immunopathology (Hussell et al.,
2014; Gwyer et al., 2012). Correspondingly, short-term exposures to biogenic PM have
been associated with a variety of inflammation-mediated health effects that include
reversible declines in pulmonary function, increased mucus production, and dyspnea
(Thorn, 2001; Kirkhorn & Garry, 2000). Repetitive biogenic PM exposures are believed
to promote non-infectious respiratory diseases such as chronic obstructive pulmonary
disease, asthma, and chronic bronchitis (Cherrie et al., 2013; Lai & Christiani, 2013;
Eduard et al., 2009; Matheson et al., 2005). These exposures and health effects are both
15
common for workers in industries such as agriculture, textiles, waste handling, and
machining (Dutkiewicz et al., 2011; Heederik et al., 2007; Hoppin et al., 2003).
While the mechanistic understanding for the immunologic hazards of these
respiratory exposures is in a constant state of evolution, the capacity to quantify such
hazards and accurately depict exposure-response relationships has remained distinctly
limited. The integrative testing methods that are necessary to evaluate the total pro-
inflammatory potential of the PM matrix remain absent from the customary suite of
exposure assessment tools and strategies. Instead, conventional practice has relied on the
measurement of individual classes of agents (e.g. – endotoxins) as proxies of pro-
inflammatory hazard (Douwes et al., 2003). This approach draws on the same exposure
assessment methods that have been in use for the past four decades and is limited, in part,
by the sheer diversity of pro-inflammatory agents in the environment.
2.3.1. Bacterial Endotoxins
The pro-inflammatory hazards of biogenic PM are most often appraised on the
basis of bacterial endotoxin content. Of the many microbial agents in the environment,
endotoxins are widely regarded as the most potent class of immunostimulatory PAMPs in
nature (Beutler & Rietschel, 2003). While the terminology for “endotoxin” generically
connotes a constitutive, immunotoxic microbial component, it is almost exclusively
employed in reference to aggregates of lipopolysaccharide (LPS) molecules from Gram-
negative bacteria. For the purposes of the discussion presented here, endotoxin will
reference these immunologically active aggregates of LPS.
The cell wall of nearly all Gram-negative bacteria is densely populated with LPS.
These amphiphilic, polar molecules are composed of a core polysaccharide (O-antigen)
16
and a lipid tail (Lipid A), which serves as an anchor into the bacterial cell membrane
(Needham & Trent, 2013). In the environment, LPS molecules readily form aggregates
that serve as ligands to the MD2/TLR4 innate pattern recognition receptor complex in the
mammalian immune system (Kawai & Akira, 2009). Although the endotoxin-TLR4
relationship is well known and extensively researched, it is noteworthy that the TLR4-
mediated pathway is not the sole means of endotoxin recognition by immune cells
(Kayagaki et al., 2013). Likewise, a variety of environmental ligands (beyond endotoxin)
have been identified for TLR4 (Kawai & Akira, 2011).
Due to the ubiquity of Gram-negative bacteria in the environment, endotoxins are
commonly present in dusts and airborne PM (Spaan et al., 2006; Simpson, 1999). They
are also contaminates of surface waters, and piped water in which biofilms have
developed (Keinänen et al., 2004; Muittari et al., 1980). The LPS molecule is uniquely
persistent in the environment and shows resistance to degradation induced by changes in
pH, temperature, and pressure (Nakata, 1993). This property of LPS allows for
concentrations of endotoxins to accumulate in the environment as the result of recurrent
LPS shedding by live Gram-negative bacteria and by bacteria death and cell lysis
(Mattsby-Baltzer et al., 1991). Thus, endotoxins are distinctive PM constituents, as their
resilience allows them to retain pro-inflammatory potential, independent of the lifespan
of the parent bacteria, translating to a non-viable biogenic hazard.
While endotoxin is prevalent at low levels in the environment, it is also detected
at remarkably high concentrations in conditions that foster bacterial growth (Basinas et
al., 2013). Bioaerosol exposures in environments such a livestock housing and cotton
processing facilities are routinely associated with a variety of non-infectious respiratory
17
symptoms (Duquenne et al., 2013; Liebers et al., 2006). Bacterial endotoxins are also
associated with the exacerbation of asthma and are considered to be important
contaminants of indoor air in the home and in office spaces (Paba et al., 2013;
Doreswamy & Peden, 2011). In the medical field, endotoxins are notorious contaminants
of pharmaceutical products, medical devices, and injectable drugs, where they are
considered one of the primary causal agents in the development of sepsis (Henderson &
Wilson, 1996). These clinical hazards have long-served as a principal motivating factor in
the scientific research of endotoxins.
For the purposes of environmental exposure assessment, there are a number of
pertinent factors that medical research has revealed about the LPS molecule. Notably, the
immunologic potency of endotoxin in the human system varies considerably as a function
the LPS Lipid A structure (Maeshima & Fernandez, 2013; Dehus et al., 2006). A variety
of studies have shown that the mammalian innate immunity discriminates between
different structural moieties of LPS as a function of the number and positioning of acyl
chains on the Lipid A tail, as well as the pattern of phosphate groups on the molecule
(Gutsmann et al., 2010; Dehus et al., 2006; Mathiak et al., 2003). In general,
hexaacylated bi-phosphorylated LPS molecules translate to the most potent endotoxins,
while fewer acyl chains or removal of phosphate groups is associated with reduced
immunotoxicity (DeMarco & Woods, 2011). Evidence also suggests that this potency is
dependent on the manner in which endotoxin is released from the bacterial cell and then
recognized by the immune system (Mattsby-Baltzer et al., 1991).
Therefore, within the class of Gram-negative LPS endotoxins, the pro-
inflammatory potential of these agents varies considerably. This is a facet of endotoxin
18
testing that has significantly complicated the risk assessment process for environmental
exposures. Endotoxin-based research has predominantly been completed using LPS from
strains of Escherichia coli (E. coli) that mimic the potency of the WHO reference
standard for endotoxin (purified LPS from E. coli 113:H10) (S. Poole et al., 1997).
Although these reference and control standard endotoxins are used for purposes of
standardization, research is routinely completed using the most potent LPS molecules.
This practice is unlikely to represent the heterogeneity of endotoxins in the environment.
This variable potency of endotoxin has been observed across animal models
(Schindler et al., 2003; Helander et al., 1982), in vitro cellular systems (Stoddard et al.,
2010; Dehus et al., 2006), and in the results of human inhalation studies in which
aerosolized doses of different endotoxins have been administered to healthy subjects. A
review by Thorn (2001) summarizes many of these studies, and research by Möller et al.
(2012) and Michel and colleagues (1997) provide examples of supporting evidence that
local and systemic inflammation from inhaled endotoxin is dose-dependent and
associated with the zone of exposure in the respiratory system. Therefore, it is important
to consider the particle sizes with which endotoxins associate in an aerosol, as particle
size is a key determinant for the site of particle deposition in the respiratory tract.
Human inhalation studies have assessed exposures of crude extracts of dust from
grain (Becker et al., 1999), cotton (Jamison & Lowry, 1986; Cavagna et al., 1969), and
livestock facilities (Harting et al., 2012), reporting comparable inflammatory responses to
that of purified endotoxin. However, when the collective results of this research are
examined, the measured health outcomes (e.g. – pulmonary function, systemic
inflammatory markers) do not consistently correlate with the measured endotoxin content
19
of the extracts used in the exposure (Poole & Romberger, 2012). This research suggests
that endotoxin content does not fully explain the pro-inflammatory potential of
environmental dusts and PM. The lack of a robust exposure-response relationship
between the endotoxin content in PM and symptoms of respiratory inflammation (e.g.-
lung function decline, wheeze) suggests that there are unique elements within the
environment and between individual immune systems that contribute to this variability.
Although endotoxin is an established pro-inflammatory constituent that frequently
burdens PM, environmental exposures to the respiratory system reflect complex mixtures
of biogenic agents. The immunologic response to these mixtures of stimuli may not be
accurately reflected by the burden or pro-inflammatory potential of any single PM
constituent. Consequently, the exposure assessment community has yet to establish
endotoxin as a reliable marker of pro-inflammatory potential and no regulatory endotoxin
exposure limits exist in the workplace.
The Dutch Expert Committee on Occupational Safety (DECOS), under The
Health Council of the Netherlands, has published the most formal occupational exposure
guidelines. The DECOS health-based guideline suggests that occupational exposures
should not exceed 100 EU/m3 (8-hr time-weighted averages) for endotoxin in the
inhalable fraction of PM (DECOS, 2010). This guideline is based on endotoxin exposure
studies from Castellan et al. (1987), Smid et al. (1992), and Post et al. (1998).
Castellan and colleagues (1987) investigated changes in the lung function of
healthy volunteers who were exposed to varying concentrations of aerosolized cotton
dust over six-hour periods. This study used spirometry to evaluate the volume of air
released in the first second of a forced expiration (FEV1) from lungs of study volunteers.
20
FEV1 was measured before and after the cotton dust exposure, serving as a standardized
measure of small airway function. The results of the study indicated a strong dose-
response relationship between the endotoxin content of the dust exposure and cross-shift
lung function decline, which was taken as the decrement in FEV1 that followed the
exposure or work shift. The authors of this study reported a No Observable Adverse
Effects Level (NOAEL) of 90 EU/m3, which formed the basis for the DECOS guideline.
Smid and colleagues (1992) conducted a cross sectional study of endotoxin
exposure and baseline lung function (FEV1) in workers from the animal feed industries.
Post et al. (1998) followed the same cohort of animal feed workers over a five-year and
period, assessing endotoxin exposure and the rate of decline in lung function. Based on
these studies, the DECOS investigators determined that 40 years of occupational
endotoxin exposure at concentrations of 90 EU/m3 or less would increase the normally
observed decline in lung function that occurs with age. Therefore, DECOS proposed an
occupational endotoxin guideline of 90 EU/m3, or lower, for both short and long-term
exposures to prevent accelerated declines in FEV1. However, the guideline carries no
binding authority in the workplace.
2.3.2. Non-Endotoxin Stimuli
In comparison to the field of endotoxin research, significantly fewer
investigations have been conducted into the immunotoxicity of non-endotoxin microbial
stimuli and little is known about their respective respiratory hazards. Hasiwa and
colleagues (2013) published a comprehensive review of these non-endotoxin constituents,
drawing on a broad cross-section of studies in which rabbit pyrogen tests, limulus
amebocyte lysate (LAL) assays, and human whole blood assays (WBA) were utilized to
21
assess inflammatory properties of endotoxin and non-endotoxin stimuli. Although the
review by Hasiwa and colleagues is geared towards testing for pyrogenic (fever-
inducing) contamination in the pharmaceutical industry, much of the discussion is
germane to the investigation of biogenic PM exposures and their pro-inflammatory
respiratory hazards. Many environments are rich with microbial sources of the same non-
endotoxin stimuli discussed by Hasiwa and associates. These sources include Gram-
positive bacteria (lipotechooic acids, lipoproteins), fungi (β-glucans, chitins, mannans),
virus (dsRNA, unmethylated CpG DNA motifs), and parasites (glycolipids) (Mogensen,
2009; van der Meer et al., 2009; Kikkert et al., 2007; Teixeira et al., 2002).
Non-endotoxin microbial motifs also signal through innate PRRs, and display the
capacity to drive the release of non-specific inflammatory mediators in a manner similar
to that of endotoxin. Thus, there is an emergent appreciation for the mechanistic basis
that supports the contribution of these stimuli to the pro-inflammatory hazards of
biogenic PM, since their sources are often equally prevalent to those of endotoxin.
Decades of bioaerosol studies employing culture-based testing methods have
demonstrated that diverse populations of fungi and bacteria (both Gram-negative and
Gram-positive) may be carried by PM (Douwes et al., 2003). More recently, culture-
independent DNA sequencing methods have begun to describe these populations at
significantly higher order of detail (Arfken et al., 2014; Blais Lecours et al., 2012).
Only a small number of inhalation studies have been conducted in humans to
assess immunologic responses to these aerosolized non-endotoxin stimuli. Hoogerwerf
and colleagues (2008) investigated the inflammatory effects of purified LPS and
lipoteichoic acids (LTA) on the human lung, reporting that both LPS and LTA were
22
capable of recruiting neutrophils to the airways of study subjects and both induced the
release of inflammatory cytokines and chemokines. However, only LPS appear to be
capable of activating neutrophils and alveolar macrophages. Meanwhile, Thorn et al.
(2001) studied the immunologic effects of inhaled fungal β-glucans in human subjects,
reporting that the exposure elicited eosinophilic responses, as opposed to the typical
neutrophilic responses that are reported to follow challenge with purified LPS (Michel et
al., 2013; Loh et al., 2006). Thus, it appears that LPS, LTA, and β-glucans carry pro-
inflammatory potential of somewhat different natures in the human respiratory system.
Additionally, in vitro testing in cellular systems has shown that the human
immune system responds differentially to β-glucans that are derived from different
sources (Noss, et al., 2013). This lends support towards the notion that broad variations in
potency exist within major classes of microbial stimuli. Further complicating the picture
is a collection of in vitro evidence, which suggests that the innate immune system’s
response to challenge with endotoxin is modulated by the presence of non-endotoxin
stimuli. Specific focus has been directed towards co-exposures to endotoxin and (1–3)-β-
D-glucans from fungal matter, due to the ubiquity of both constituents in the environment
(Kikkert et al., 2007). The innate immune response to mixtures of stimuli is not well
understood, and at the time this review was drafted, there were no known inhalation
studies that assessed responses to mixtures of PAMPs, with only a few in vitro studies.
Taken together, the results of this body of research suggest that studies of
biogenic PM should ensure that fungal and Gram-positive bacterial sources of pro-
inflammatory stimuli are accounted for in the evaluation of respiratory hazards. Given the
human immune system’s sensitivity to an exquisite array of microbial agents, an
23
endotoxin-centric focus on biogenic PM exposures is unlikely to provide a full picture of
pro-inflammatory potential or hazard. However, nearly all testing for biogenic PM
continues to be completed using the horseshoe crab Limulus Amebocyte Lysate (LAL)
test, which is a test that is specific to the detection of endotoxin.
!
24
2.4. Endotoxin and Non-Endotoxin Testing Methods
2.4.1. Limulus Amebocyte Lysate (LAL) Test
The standard assay for the detection of endotoxin is the LAL test, which is an in
vitro endotoxin assay that is commonly used across the fields of medicine and
environmental health. The LAL test relies on an enzymatic-clotting cascade in the
haemolymph of the Atlantic horseshoe crab (Limulus polyphemus) to detect endotoxin
(Devleeschouwer et al., 1985). Additionally, LAL tests for β-glucans (LAL-g) (Foto et
al., 2004) are commercially available, and a Recombinant Factor C (rFC) test has been
developed to detect endotoxins based on a recombinant form of the key factor (Factor C)
in the clotting cascade of the horseshoe crab’s blood (Thorne et al., 2010). In the field of
exposure assessment, the kinetic chromogenic version of the LAL assay is the most
frequently employed for its increased sensitivity, although gel-clot and endpoint assays
remain in use as well (Paba et al., 2013). The use of different LAL formats has hindered
the standardization for endotoxin testing.
It is important to note that LAL-based endotoxin-testing approaches rely on the
kinetics of the arthropod immune system, which detects and responds to endotoxins in a
manner that is fundamentally different from the mammalian immune system (Gutsmann
et al., 2010; Iwanaga, 2007). Accordingly, the sensitivity of the LAL test does not reflect
that of the human immune system with regard to endotoxin from different types of
bacteria. As a result, this assay may not provide a biologically relevant measure of the
human response to endotoxin in environmental samples (Gutsmann et al., 2010; Stoddard
et al., 2010; Brandenburg et al., 2009; Dehus et al., 2006).
!
25
Tab
le 2
.1.
LA
L a
nd W
BA
test
ing
cons
ider
atio
ns
Fact
or
LA
L T
estin
g W
BA
Ana
lysi
s D
etec
t bot
h
endo
toxi
n an
d no
n-
endo
toxi
n st
imul
i
Onl
y de
tect
s end
otox
in (L
AL
or rF
C).
No
qual
itativ
e or
quan
titat
ive
insi
ght i
nto
non-
endo
toxi
n co
nstit
uent
s
(with
exc
eptio
n of
LA
L as
say
spec
ific
for β
-Glu
cans
).
Inte
nded
to p
rovi
de in
tegr
ated
imm
unol
ogic
resp
onse
to a
ll
rele
vant
stim
uli i
n sa
mpl
e. M
ay m
easu
re m
ultip
le im
mun
olog
ic
mar
kers
of i
mm
une
resp
onse
from
sam
e te
st.
Bio
logi
cally
rel
evan
t
endp
oint
s
LAL
test
is p
redi
cate
d on
hor
sesh
oe c
rab
imm
une
syst
em, a
nd th
e te
st’s
sens
itivi
ty to
end
otox
in is
not
equi
vale
nt to
the
hum
an im
mun
e re
spon
se.
WB
A is
relia
nt o
n th
e di
rect
exp
osur
e of
hum
an p
rimar
y im
mun
e
cells
to th
e sa
mpl
e of
inte
rest
. Tes
t con
duct
ed in
the
spec
ies o
f
inte
rest
, usi
ng a
robu
st b
iolo
gic
syst
em.
Tes
t sam
ple
mat
rice
s
with
inso
lubl
e PM
Chr
omog
enic
LA
L on
ly a
sses
ses w
ater
-sol
uble
stim
uli.
Inca
pabl
e of
det
ectin
g pa
rticl
e or
filte
r-bo
und
endo
toxi
n.
Resp
onds
to b
oth
solu
ble
and
inso
lubl
e st
imul
i, an
d is
am
enab
le
to te
stin
g w
ith e
ndot
oxin
inhi
bito
rs, s
uch
as P
olym
yxin
B.
Res
ista
nt to
sou
rces
of a
ssay
inte
rfer
ence
Pron
e to
fals
e po
sitiv
es fr
om a
gent
s su
ch a
s fu
ngal
β-
Glu
cans
, bac
teria
l DN
A, a
nd p
rote
ase
inhi
bito
rs.
Sinc
e th
e W
BA
is a
n in
tegr
ated
resp
onse
to a
ll st
imul
i in
a
sam
ple,
inte
rfer
ence
is re
duce
d an
d ch
ecke
d w
ith s
pike
d sa
mpl
es
Com
mer
cial
avai
labi
lity
of te
st
reag
ents
Ava
ilabl
e th
roug
h se
lect
ven
dors
, alth
ough
the
hors
esho
e cr
ab p
opul
atio
n is
frag
ile a
nd n
egat
ivel
y
impa
cted
by
harv
estin
g of
cra
bs fo
r LA
L pu
rpos
es.
Can
be
com
plet
ed u
sing
wid
ely
avai
labl
e co
mm
erci
al re
agen
ts.
Hum
an w
hole
blo
od is
read
ily a
vaila
ble
and
bloo
d dr
aws
are
rout
ine,
low
risk
pro
cedu
res.
No
anim
als
invo
lved
in te
stin
g.
Hig
h th
roug
hput
capa
city
&
stan
dard
izat
ion
LAL
is c
apab
le o
f hig
h th
roug
hput
test
ing
on li
mite
d
basi
s, u
sing
LA
L ve
ndor
-sup
plie
d te
stin
g pl
atfo
rms.
Val
idat
ed fo
r use
with
poo
led,
cry
opre
serv
ed b
lood
. Inc
ubat
ion
volu
mes
can
be
varie
d an
d cy
toki
ne a
naly
sis
may
be
mul
tiple
xed.
!
26
The limitations of the LAL assay are compounded by its susceptibility to
interference from other environmental agents (i.e. - β-glucans, genetic material), and its
inability to detect particle-bound endotoxin or endotoxin carried in turbid aqueous
samples (Thorne et al., 2010; Kindinger et al., 2005). The preparation of PM samples for
LAL testing requires a multi-step extraction process to solubilize endotoxin from the air
sample and elute it into an aqueous medium (Spaan et al., 2008; Spaan et al., 2007). This
extraction process also creates challenges in the standardization of testing protocols.
Despite efforts to standardize LAL testing, previous studies have reported a variety of
factors that contribute to variations in test results (Reynolds et al., 2002, 2005; Douwes et
al., 1995). These studies show that differences in results are attributed to factors that
include the filter extraction medium, air filter material, storage of samples, and the type
of LAL used (e.g. - gel-clot, kinetic, endpoint).
LPS molecules have a high affinity for plastic surfaces, and for air sampling,
unknown quantities of endotoxin may adhere to air filter membranes. The recovery of
endotoxin from these air filter samples is not well defined. Additionally, since the
insoluble particles must be removed prior to testing, cell and particle-bound endotoxins
are often discarded from the sample via centrifugation prior to testing. The content of
endotoxin carried by the insoluble PM fraction is unclear, although Eduard and
colleageus (2004) suggest that the solubility is highly variable (range: 9% - 83%). The
impact of variable water solubility may have profound effects on the measured endotoxin
content of samples and illustrates the need for strict standardization of testing protocols.
In addition to LAL testing, gas chromatography with mass spectrometry (GC/MS)
has also been used in endotoxin studies to characterize the 3-Hydroxy fatty acids from the
!
27
Lipid A tail of the LPS molecule (Poole et al., 2010; Saito et al., 2009; Pomorska et al.,
2007). GC/MS is also used to assess the content of ergosterol as a marker of fungal
contamination and muramic acid as a marker for peptidoglycans (Szponar & Larsson,
2001). While this GC/MS method very finely characterizes the chemical composition of
the Lipid A and provides insight towards the variety of Lipid A structures in the sample,
it is an expensive method that is also time intensive and requires complicated sample
preparation. The results of 3-Hydroxy fatty acid testing via GC/MS provide a poor
quantitative measure of exposure and also do not provide results of biologic relevance.
2.4.2. Whole Blood Assay (WBA) Methods
In vitro models using human immune cells have been used as an alternative
testing method to the LAL for the detection of both endotoxin and non-endotoxin stimuli.
Many studies have investigated the immunotoxic properties of PM with monocultures of
immune cells from immortalized cell lines (e.g. – THP-1, Mono-Mac-6) or isolated
populations of peripheral blood mononuclear cells (PBMCs) (McConnell et al., 2013;
Steenhof et al., 2011; Soukup & Becker, 2001). However, only a small number of studies
have pursued the use of human whole blood assay (WBA) methods for the evaluation of
PM. The WBA model represents a unique approach towards the analysis of complex
environmental samples and carries the biologic complexity necessary to holistically
assess immunologic responses to mixtures of stimuli.
!
28
Tab
le 2
.2.
Lis
t of p
ublis
hed
stud
ies
usin
g W
BA
met
hods
for
anal
ysis
of P
M s
ampl
es
Nam
e R
efer
ence
B
lood
Incu
batio
n
PM S
ize
Frac
tion
WB
A
Res
pons
e
# of
sam
ples
Sam
plin
g Si
te
LA
L
Tes
t
Sam
ple
Mat
rix
Mea
sure
men
t of a
ir-b
orne
pyr
ogen
s by
the
in v
itro
pyro
gen
test
(IPT
) bas
ed o
n
hum
an w
hole
blo
od c
ytok
ine
resp
onse
Kin
ding
er
et a
l. (2
003)
Fres
h
Blo
od
(indi
vidu
al
dono
rs)
Inha
labl
e IL
-1β
N/A
Sh
eep
and
pig
stab
les
Y
Who
le
filte
rs &
impi
nger
fluid
A ne
w m
etho
d to
mea
sure
air
-bor
ne
pyro
gens
bas
ed o
n hu
man
who
le b
lood
cyto
kine
res
pons
e
Kin
ding
er
et a
l. (2
005)
Cry
o-
pres
erve
d
(poo
led)
Tota
l IL
-1β
N/A
Pi
g &
dai
ry
barn
s, w
aste
recy
clin
g
Y
Who
le
filte
rs &
extra
cts
Det
erm
inat
ion
of th
e in
flam
mat
ory
pote
ntia
l of b
ioae
roso
ls fr
om a
duc
k-
fatte
ning
uni
t by
usin
g a
limul
us
ameb
ocyt
e ly
sate
ass
ay a
nd h
uman
who
le b
lood
cyt
okin
e re
spon
se
Zuck
er e
t
al. (
2006
)
Fres
h
Blo
od
(indi
vidu
al
dono
rs)
Inha
labl
e,
Impi
nger
fluid
IL-1β
17
Duc
k
Fatte
ning
Hou
se
Y
Filte
r
Extra
ct
&
Impi
nger
Flui
d
Stan
dard
izat
ion
of w
hole
blo
od a
ssay
for
dete
rmin
atio
n of
pyr
ogen
ic a
ctiv
ity
in o
rgan
ic d
ust s
ampl
es
Lieb
ers
et
al. (
2009
)
Cry
o-
pres
erve
d
(poo
led)
N/A
IL
-1β,
IL-6
,
TNFα
, IL-
8,
MC
P-1
30
Gra
in fa
cilit
y,
chic
ken
&
pige
on s
tabl
e
Y
Filte
r
Extra
cts
!
29
Tab
le 2
.2.
(con
tinue
d) L
ist o
f pub
lishe
d st
udie
s us
ing
WB
A m
etho
ds fo
r an
alys
is o
f PM
sam
ples
Nam
e R
efer
ence
B
lood
Incu
batio
n
PM S
ize
Frac
tion
WB
A
Res
pons
e
# of
sam
ples
Sam
plin
g Si
te
LA
L
Tes
t
Sam
ple
Mat
rix
Eval
uatio
n of
qua
ntifi
catio
n
met
hods
of o
ccup
atio
nal
endo
toxi
n ex
posu
re
Lieb
ers
et a
l.
(200
7)
Fres
h
(indi
vidu
al
dono
rs)
Tota
l IL
-1β
55
Swin
e, d
uck,
rat
& m
ice
hous
ing,
and
an o
ffic
e
setti
ng
Y
Filte
r
Extra
cts
(par
ticle
free
)
Pyro
geni
c ac
tivity
of a
ir to
char
acte
rize
bio
aero
sol e
xpos
ure
in p
ublic
bui
ldin
gs: a
pilo
t stu
dy
Bern
asco
ni e
t al.
(201
0)
Cry
o-
pres
erve
d
(poo
led)
Tota
l IL
-1β
N/A
O
utdo
or A
ir,
Indo
or O
ffic
e A
ir
N
Who
le
Air
Filte
rs
Asse
ssm
ent o
f air
born
e ex
posu
re
to e
ndot
oxin
and
pyr
ogen
ic
activ
e du
st u
sing
ele
ctro
stat
ic
dust
fall
colle
ctor
s (E
DC
s)
Lieb
ers
et a
l.
(201
2)
Cry
o-
pres
erve
d
(poo
led)
EDC
(Set
tled
dust
)
IL-1β
&
MC
P-1
61
Com
post
ing
plan
ts &
hous
ehol
d in
door
air
Y
EDC
extra
cts
(par
ticle
free
)
Con
cent
ratio
n of
bio
aero
sols
in
com
post
ing
plan
ts u
sing
diff
eren
t
quan
tific
atio
n m
etho
ds
van
Kam
pen
et a
l.
(201
4)
Cry
o-
pres
erve
d
(poo
led)
Inha
labl
e
IL-1β
124
Com
post
ing
plan
ts
Y
Filte
r
Extra
cts
!
! 30
The human WBA relies on the ex vivo stimulation of diluted, heparinized
peripheral whole blood to elicit the release of acute phase cytokines from leukocytes,
with the primary response attributed to blood monocytes (Hartung & Wendel, 1995). This
cytokine release represents an integrated immunologic response to the cumulative burden
of endotoxin and non-endotoxin stimuli in the exposure. In this manner, the WBA model
provides a unique immunologic interface in which the PM sample is brought into direct
contact with primary immune cells of the peripheral whole blood system. The use of
whole blood is important in this test as it maintains the integrity of the whole blood
system, including monocytes and an extensive collection of soluble components (e.g. –
complement, soluble CD14, LPS-binding protein), which are critical in the detection of
PAMPs and the overall function of the system (Hasiwa et al., 2013).
Whole blood is diluted in sterile cell culture medium and incubated with stimuli
under physiologic conditions for 18 – 24 hours (Daneshian et al., 2009). Cytokine
responses are measured in the supernatant of the whole blood incubation with an enzyme-
link immunosorbent assay (ELISA). The WBA methods referenced here are predicated
on the human fever response to pyrogenic stimuli (Dinarello, 2004; Hartung & Wendel,
1995), and primarily rely on the release of the non-specific inflammatory cytokines
Interleukin (IL) -1β and IL-6 from blood monocytes as a measure of response (Daneshian
et al., 2009). These cytokines have been adopted as suitable markers of pro-inflammatory
potential as their production is highly conserved and they are released in a dose-
dependent manner to stimulation with a variety of PAMPs (Liebers et al., 2009;
Deininger et al., 2008; Hermann et al., 2002).
!
! 31
The suggested positive control for this assay is purified LPS from a reference
strain of E. coli. Incubation of a endotoxin dilution series with PM samples allows for the
WBA response to samples to be referenced back against the cytokine response curve
generated by the positive controls. These sample responses are then communicated in
terms of “equivalent endotoxin units” and represent the quantity of reference endotoxin
necessary to generate an pro-inflammatory cytokine response equivalent to that of the
sample (Montag et al., 2007). Since PM samples may carry unknown burdens of stimuli,
this method represents a novel approach towards communicating the pro-inflammatory
potential of PM samples under a standardized metric.
The WBA carries the capacity to detect endotoxin and non-endotoxin stimuli in
both liquid and solid samples. A previous study by Kindinger and colleagues (2005)
uniquely demonstrated that entire polytetrafluoroethylene air filter samples could be
directly incubated in whole blood, circumventing the need to extract particles from the
filter and eliminating the potential for losses of stimuli from the original PM matrix.
Additionally, the WBA assay has also been shown to work in conjunction with endotoxin
inhibitors (e.g. – Polymyxin B) (Rivera-Mariani et al., 2014), anti-TLR antibodies
(Punsmann et al., 2013), and novel TLR2 antagonists (Propylene Glycol) (Draing et al.,
2008). WBA methods have also been used in research to measure a variety of mediators,
including chemokines (Møller et al., 2005), prostaglandins (von Aulock et al., 2003) and
lymphokines (Hermann et al., 2003). The assays are amenable to high-throughput
methods. Van Dooren and colleagues (2013) have demonstrated that a multiplexed
analysis may be completed to assess a broad panel of cytokines and chemokines into the
cell-free supernatant of whole blood incubations.
!
! 32
As opposed to the singular readout of the LAL test, an abundance of immunologic
data may be extracted from whole blood incubations, which are capable of providing
relevant insight into both innate and adaptive human immune responses. Peripheral whole
blood is a non-commercial commodity and blood draws are considered to be routine, low
risk activities. Heparinized fresh whole blood is reported to remain responsive to
stimulation for up to four hours after it has been drawn (Daneshian et al., 2009), and
donors may be pre-screened for infection, allergy, or immunologic susceptibilities that
may impact the response of the assay. The use of blood from individual donors preserves
the immunologic characteristics of the donor whole blood system. Testing blood from
different donors against the same stimuli allows for WBA responses between individuals
to be contrasted (Noss et al., 2013; Punsmann et al., 2013; Harting et al., 2012).
The WBA has also been validated for use with cryopreserved whole blood that
has been pooled from multiple donors. In the context of biogenic PM analysis, this is an
important alternative to the use of fresh blood, as it serves to normalize individual
differences in the whole blood system (e.g. – monocyte counts) and endows blood with
characteristics of a standardized reagent for the assay. Pooled blood may be
cryopreserved with a protocol developed by Schindler and colleagues (2004) and stored
at -80°C, or colder. Therefore, whole blood incubations can be completed on a schedule
that is independent of the blood collection. The cryopreserved WBA may be used with
pooled batches of blood to investigate the cytokine response to different types of PM
samples or samples from different environments (Schindler et al., 2004). These WBA
methods are promising for situational use in exposure assessment, as they provide
!
! 33
integrative testing methods with which to reproducibly evaluate complex sample
matrices.
However, WBA methods have only been used for air quality analysis on a limited
basis (as summarized in Table 2.2), and considerable work remains to optimize the test
for exposure assessment, such that PM samples may be efficiently and reliably evaluated.
Similar to LAL-based endotoxin analysis, the increased standardization of WBA testing
methods is crucial in order to ensure the integrity and generalizability of results. The
heterogeneous composition of whole blood introduces a number of important limitations
that must be carefully addressed to accurately evaluate the biogenic fraction of PM on a
quantitative basis. In particular, the whole blood system’s sensitivity towards microbial
stimuli (e.g. – endotoxin) may vary considerably (both between individuals, and within
the same individual over time), and the acute phase cytokine response to this stimulation
represents a non-specific marker of inflammatory activity.
While WBA testing with pooled, cryopreserved whole blood provides a
mitigation strategy against individual blood donor differences that may contribute to
variations in cytokine response, it does not fully eliminate them (Liebers et al., 2009).
Monocytes are the primary source of the acute phase cytokines commonly measured in
WBA testing, yet the sensitivity of the acute phase response is influenced by a diverse
variety of factors that include the dynamic nature of leukocyte sub-populations, atopic
sensitization, and circadian rhythms (e.g. – endogenous cortisol levels) (Hermann et al.,
2006). These potential sources of immunologic variability should be carefully considered
when the WBA is used as an assay to evaluate the pro-inflammatory potential of PM, or
when it is used as a test of individual immunologic responsiveness.
!
! 34
The use of appropriate positive and negative controls is necessary to ensure that
the assay is free of contamination and interference. To minimize the variation in testing
conditions over time, consistency should be maintained in the type of purified LPS used
for positive controls, and the source of sterile cell culture media and incubation vessels.
The response of the WBA is dependent on many factors, including incubation conditions,
assay reagents, and the composition and viability of the blood used in the test.
The pre-screening of donor blood for differential leukocyte counts (e.g. –
monocytes, eosinophils) and other potential markers of infection (e.g. – C-Reactive
Protein, LPS Binding Protein) may serve to allow for critical compositional factors of
whole blood to be controlled for in the experimental design and analysis of data. It is also
noted that whole blood carries a variety of endogenous danger-associated molecular
patterns (DAMPs), which may synergistically intact with PAMPs and other stimuli to
influence the assay response. Namely, extracellular hemoglobin has been shown to
potentiate responses to PAMPs such as endotoxin and LTA (Lee & Ding, 2013, Cox et
al., 2012). Red blood cell damage during the handling, storage, and incubation of cells
may result in false positive responses or inappropriately amplify cytokine responses to
environmental samples.
While the whole blood system affords the immunologic complexity to evaluate
the burden of stimuli in biogenic PM, the resulting release of acute phase cytokines is a
non-specific marker of response. Samples of environmental PM often carry an unknown
burden of stimuli and it is difficult to ascertain the primary immunostimulatory
constituents in the sample matrix using results from the WBA, alone. Although the use of
endotoxin inhibitors (e.g.- Polymyxin B) in the WBA allows for the response to non-
!
! 35
endotoxin stimuli in a sample to be assessed, further compositional analysis of the sample
is often necessary to parse out the individual classes of stimuli that likely represent the
predominant pro-inflammatory hazards in the sample.
It also must be re-emphasized that the WBA is a test to model the acute phase
inflammatory response to stimuli in a sample. The response of the WBA may not directly
correlate with the local innate immune response in the respiratory system. Further
research utilizing the WBA in human exposure studies is necessary to correlate WBA
responses with measures of pulmonary function and respiratory inflammation.
!
! 36
2.5. Discussion
The LAL and WBA methods discussed here both have roles in the evaluation of
biogenic PM hazards. While multiple limitations of the LAL test have been highlighted
here, the utility of the assay cannot be discounted as it has provided one of the only
means for detecting endotoxin in PM samples. In many instances, endotoxin can serve as
an important, easily assessed surrogate for a broader biogenic pro-inflammatory signal.
However, over three decades of endotoxin-based research has yet to fully explain the
respiratory hazards of these biogenic PM exposures. There is both purpose and need to
advance the standards for in vitro testing strategies in this field of research and include
methods that are both biologically relevant and immunologically sensitive to endotoxin
and non-endotoxin stimuli in environmental PM.
Globally, these exposures impact an expansive workforce and carry a significant
burden on health care costs, productivity in the workplace, duration of occupational
careers, and the personal health and well-being of exposed workers. Numerous
occupational sectors are associated with both biogenic PM exposure and chronic
respiratory disease environments. These industries include (but are not limited to):
agriculture (Spaan et al., 2006), textiles (Lai & Christiani, 2013), food processing (
Simon & Duquenne, 2014; Sakwari et al., 2013), lumber milling (Fransman et al., 2003),
fiberglass (Milton et al., 1996), and metalworking (Gilbert et al., 2010; Laitinen et al.,
1999). PM exposures in these industries are associated with acute conditions that include
episodes of wheeze, cough, dyspnea, and cross-shift lung function decline (Andersen et
al., 2004; Donham et al., 2000). Workers are also at higher odds to develop permanent
!
! 37
disorders such as COPD, chronic bronchitis, asthma, and hypersensitivity pneumonitis
(Eduard et al., 2009; Matheson et al., 2005; Oesmi et al., 1987).
Agricultural occupations are the most commonly associated with high exposures to
endotoxin and biogenic PM, and they also share a long history of chronic respiratory
illness (Kirkhorn & Garry, 2000). Livestock care and animal husbandry workers appear
to bear the highest risks for developing these respiratory diseases (Samadi et al., 2013;
Eduard et al., 2009; Hoppin et al., 2003). Workers in industrialized animal production
facilities are thought be the most highly exposed to biogenic PM and there is considerable
concern for the long-term health implications of these exposures (Heederik et al., 2007).
Compositional analysis of PM from animal housing facilities indicates the presence of a
variety of potent immunomodulatory agents, including viable microorganisms, non-
viable microbial constituents, pollens, animal dander and enzymes, metals, and
antibiotics (Biswas et al., 2012; Viegas et al., 2012; Trabue et al., 2010). The respiratory
hazards of animal housing environments are underscored by studies in equine and swine
facilities, which show that these animals also develop a variety of non-infectious
respiratory symptoms and disease that are positively associated with increasing exposures
to PM (Theegarten et al., 2008).
Beyond agriculture, the textile industry is similarly burdened by a lengthy history of
obstructive respiratory diseases (e.g. – byssinosis), related to chronic exposures to dust
derived from raw and processed cotton (Lai & Christiani, 2013). These health effects
have been studied in depth since the 1950’s (Furness & Maitland, 1952) and a variety of
occupational tasks have been strongly associated with exposure to aerosolized endotoxins
and reduced pulmonary function (Kennedy et al., 1987). While the source of endotoxin in
!
! 38
cotton dust has commonly been attributed to bacteria from the Enterobacter genus
(Rylander & Lundholm, 1978), further microbiological studies have indicated high levels
of fungal species, including Alternatia and Cladosporium (Domelsmith et al., 1988).
Within the manufacturing industry, machining and metalworking occupations are
also associated with endotoxin exposure and respiratory symptoms. Industrial processes
that employ metal working fluids (MWF) often generate high concentrations of oil mists
and aerosols. These lubricants offer abundant sources of nutrients for microbes and often
habitually reused in the workplace, which allows for significant microbial populations to
develop and impart components, such as endotoxins, into the MFW medium. Exposure
studies have report high level of contamination from Gram-positive and Gram-negative
bacteria, mycobacterium, and fungi (Fishwick et al., 2005) (Murat et al., 2012).
MFW also often contains biocides, which are added to curb microbial growth
(Murat et al., 2012). However, these additives do little to degrade non-viable microbial
PAMPs and biocides, themselves, may represent respiratory hazards. Occupational
exposure to MWF is associated with the development of acute symptoms such as wheeze
and cough, as well as choric effects that include asthma, hypersensitive pneumonitis, and
chronic bronchitis (Fornander et al., 2013; Jaakkola et al., 2009; Fishwick et al., 2005).
While endotoxins are commonly isolated from MWF aerosols, polymicrobial populations
are known to be present in the MFW medium, as well as chemicals and metals.
!
! 39
2.6. Conclusion
Occupational exposures to biogenic PM and respiratory inflammation are
common themes across many industries. The biogenic fraction of constituents in PM
from the environments often contains a composite of endotoxin and non-endotoxin agents
that carry an innate capacity to engage the human immune system and stimulate
inflammatory responses. However, the customary single-component (i.e. - endotoxin)
approach provides limited insight into inhalation risks when diverse arrays of pro-
inflammatory stimuli are present. Human WBA methods represents one approach that has
displayed a potential to holistically assess complex mixtures of stimuli and provide
quantitative results of biologic relevance. While significant work remains to adapt these
methods to air quality analysis, they promise to provide a higher order of insight into both
the pro-inflammatory potential of biogenic PM and possible individual immunologic
susceptibilities to exposure.
!!!
!
!
! 40
Chapter 3
!!Whole Blood Assay Evaluation of Pro-Inflammatory Stimuli in
Broiler Poultry House Particulate Matter
Jesse P. Negherbon
Johns Hopkins Bloomberg School of Public Health
Department of Environmental Health Sciences
615 N. Wolfe St., Baltimore, MD 21205
Keywords: Endotoxin, Broiler Poultry, Whole Blood Assay, Particulate Matter
!
! 41
3.1. Abstract
The inhalation of broiler poultry house particulate matter (PM) often results in
airway inflammation and occupational exposure is associated with development of non-
infectious respiratory disease in poultry workers. This inflammation is thought to be
mediated by both endotoxin and non-endotoxin stimuli, yet the aggregate pro-
inflammatory potential of poultry PM is not well understood. This study aimed to
evaluate the burden of stimuli in respirable, thoracic, and inhalable particle size fractions
of broiler poultry PM. A dairy barn and ambient air in Baltimore City were sampled for
comparison. PM was sampled onto non-pyrogenic polytetrafluoroethylene filter
membranes and then eluted into a sterile aqueous medium. A Limulus Amebocyte Lysate
(LAL) test was used to quantify PM endotoxin content and pro-inflammatory potential
was also evaluated based on the capacity of samples to elicit the release of the
inflammatory cytokine Interleukin (IL)-1β in a cryopreserved human whole blood assay
(WBA). The endotoxin content and pro-inflammatory potential of poultry PM varied over
the growth cycle of the flock. This stimulus was predominantly carried in the non-
respirable fraction of particles. WBA cytokine release was significantly attenuated by the
removal of insoluble particles from extracts, as well as the use of an endotoxin inhibitor.
The results of this study demonstrate that poultry house PM carries a complex and
dynamic burden of constituents, which are capable of stimulating the release of
conserved inflammatory mediators from the human innate immune system.
!
! 42
3.2. Introduction
The United States (US) supports the largest broiler poultry industry in the World,
producing close to nine billion broilers each year (USDA, 2013). These broiler flocks are
housed in an estimated 29,000 industrial poultry facilities across the US, which raise high
densities of birds to market weight over seven week cycles (MacDonald, 2014). Daily
care for these flocks is contracted out from industrial hatcheries to small farming
operations, who provide labor and housing facilities (Ollinger et al., 2005). While
industrial broiler houses are engineered for efficiency and may raise flocks of 600,000 or
more birds at one time, they foster harsh working conditions and are associated with
exposures to high concentrations of particulate matter (PM) and bacterial endotoxins
(Donham, 2010). An increasing epidemiologic evidence-base suggests that livestock
workers, including those in poultry houses (broilers and layers), are at increased risk for
developing non-infectious respiratory disorders that range from cross-shift lung function
decline and dyspnea to chronic bronchitis and chronic obstructive pulmonary disease
(Eduard et al., 2009; Kirychuk et al., 2003; Donham et al., 2000).
Broiler poultry house PM is principally generated by the re-suspension of dusts
that have been derived from feces, feed, dander, and bedding materials. As a
consequence, it carries a heterogeneous mixture of constituents from biologic sources
(biogenic), including residual microbial components from Gram-negative bacteria
(endotoxins), fungi (β-glucans, mycotoxins), and Gram-positive bacteria (lipoteichoic
acids, peptidoglycans) (Lawniczek-Walczyk et al. 2013; Rimac et al., 2010; Viegas et al.,
2012). Many of these microbial components are individually capable of engaging defense
mechanisms of the innate immune system (e.g. – pattern recognition receptors,
!
! 43
complement), and stimulating non-specific inflammatory activity (Takeuchi & Akira,
2010). Thus, both the concentration and composition of this PM are thought to influence
respiratory health hazards for exposed poultry workers.
Bacterial endotoxins are structural components of nearly all Gram-negative
bacteria and are considered to be important PM constituents in these exposures. These
lipopolysaccharide (LPS) molecules are capable of stimulating airway inflammation and
are present at high concentrations in the indoor air of poultry houses (Basinas et al., 2012;
Kirychuk et al., 2006). The standard assay for the detection of endotoxin in PM is the
Limulus Amebocyte Lysate (LAL) test, which operates on the basis of endotoxin-specific
clotting mechanisms derived from the blood of the Atlantic Horseshoe crab (Limulus
polyphemus) (Iwanaga, 2007). However, the LAL test does not detect non-endotoxin
stimuli and responds to endotoxins from different species of Gram-negative bacteria with
a lesser degree of sensitivity than the human immune system (Brandenburg et al., 2009).
The LAL test is further limited to testing only the water-soluble fraction of stimuli in PM
(excluding particle-bound endotoxin) and is prone to interference from common
environmental contaminants, such a fungal polysaccharides (Gutsmann et al., 2010;
Liebers et al., 2007). Taken together, these limitations suggest that endotoxin
measurement via LAL testing may not provide an adequate proxy for the total pro-
inflammatory potential of complex biogenic PM, possibly contributing to exposure
misclassification.
One alternative method for holistically evaluating the burden of stimuli in the PM
matrix is the human whole blood assay (WBA) (Hartung & Wendel, 1995). This method
relies on the innate immune defense mechanisms of the human whole blood system (e.g.
!
! 44
– blood monocytes, complement) to detect and respond to stimuli under controlled ex
vivo exposures (Daneshian et al., 2009). The release of acute phase pro-inflammatory
cytokines, such as Interleukin (IL)-1β and IL-6, is measured as marker of response in the
incubation supernatant, using an Enzyme Linked Immunosorbent Assay (ELISA). This
method was originally developed to screen for pyrogenic contamination in injectable
drugs and medical devices, and has been used on a limited basis for air quality analysis
(Liebers et al., 2009; Zucker et al., 2006; Kindinger et al., 2005).
The WBA represents an integrated in vitro testing method, which is sensitive to a
broad range of endotoxin and non-endotoxin stimuli, and has proven capable of
evaluating complex liquid and solid sample matrices (Hasiwa et al., 2013; Dehus et al.,
2006). The assay has also been internationally validated for use with either fresh human
whole blood or cryopreserved whole blood, which may be pooled from multiple donors
(Schindler et al., 2006; Hoffmann et al., 2005). The use of pooled, cryopreserved blood is
attractive for the purposes of air quality analysis and exposure assessment, as this
exercise serves to normalize inter-individual differences in the whole blood system (e.g. –
monocyte counts, soluble factors). This process creates batches of pooled blood that may
be stored at -80°C and thawed as needed for testing over of a period of time.
Previous studies by Kindinger et al. (2005) and Liebers and colleagues (2014),
(2009), (2007), represent the only published investigations that are known to have used
these cryopreserved WBA methods for the explicit analysis of air samples. However, no
studies are known to have pursued this approach as means to evaluate the total pro-
inflammatory potential of broiler poultry house PM, or to investigate the distribution of
stimuli across particle size fractions. We hypothesize that the human WBA, with
!
! 45
cryopreserved blood, provides a unique approach to evaluating and communicating the
burden stimuli in size-specific fractions of biogenic PM.
The principal aim of this study was to sample PM from the indoor air of active
broiler poultry houses and quantitatively assess the pro-inflammatory burden of
endotoxin and non-endotoxin constituents in the respirable, thoracic, and inhalable
particle size fractions. The aggregate pro-inflammatory potential of this PM was assessed
using a WBA with pooled, cryopreserved human whole blood. Bacterial endotoxin
content was quantified with an kinetic chromogenic LAL test. To add context to this
analysis, we sought to contrast the pro-inflammatory characteristics of broiler poultry PM
with similar PM samples from an active dairy cow barn and the ambient air of Baltimore
City.
!
! 46
3.3. Materials and Methods
3.3.1. Sampling Environments and Ethics Approval
Johns Hopkins Bloomberg School of Public Health (JHSPH) Institutional Review
Board approved this study (No: 00004693). PM was collected from the indoor air of two
broiler poultry houses, a dairy cow barn, and ambient air of Baltimore City. The poultry
and dairy facilities utilized for this study were research units operated by investigators
from the University of Delaware’s Department of Animal and Food Sciences. Although
these facilities were smaller in scale that industrial operations, they were constructed and
operated for the purpose of simulating industry practices. Given the management of these
houses, we believe the conditions were suitable for the purposes of investigating the pro-
inflammatory burden of poultry PM. These facilities also represent model environments
in which regular exposure occurs for researchers who tend to the flocks on a daily basis.
A single boiler poultry house (House A, Figures 3.1, 3.2, & 3.3) was sampled on
consecutive days in November of 2013, during the final week of a flock’s 42-day growth
cycle. The second house (House B, Figure 3.4) was similar in size and construction.
House B was sampled four separate times while it contained a single flock of broilers,
between September and November of 2014, and once prior to the arrival of the flock.
Each poultry house held 2,000 birds at the time of sampling in a floor space of
approximately 167 square-meters. Bedding consisted of a mixture of wood chips, feces,
feed, and feathers on a soil base. However, bedding in House A was not regularly
changed between flocks, while the bedding in House B was replaced just prior to the
arrival of the flock sampled. Both of these facilities were equipped with mechanically
controlled ventilation and heating, artificial light, and metered feed and water stalls.
!
! 47
Figure 3.1. Exterior of broiler poultry house A
Figure 3.2. Interior of Bay 1 in broiler poultry house A
!
! 48
Figure 3.3. Floor plan of broiler poultry house A
Figure 3.4. Floor plan of broiler poultry house B
!
! 49
Area samples of PM adhering to the respirable, thoracic, and inhalable particle
size classifications were collected from each house (ACGIH, 2012). Samplers were
placed at an elevation of 1.5 meters (m) above the floor to approximate a worker’s
breathing zone. All sampling equipment was tethered to portable stands, which were
positioned away from the influence of active exhaust fans and vents. Poultry House A
had air intakes along the eves of the roof and four circular exhaust fans (see Figure 3.3).
This house had two independently controlled bays that each held 2,000 broilers. Only one
bay was sampled for this study. Poultry House B featured three mechanically operated
fans and air intake vents positioned along the length of the eves of the roof, at a height of
2.0 m above the facility floor (Figure 3.4). Time-integrated samples were collected over
periods of four to six hours. Duplicate or triplicate samples were collected in parallel for
each sampling event. Background samples of PM in House B were also collected, which
consisted of continuous sampling over a three-day span before the flock arrived.
The dairy barn used for this study was an open-air structure with a concrete floor.
The building was situated adjacent to a grain silo and a hay barn, and contained a variety
of circulating fans (0.6 – 1.2 m in diameter) for auxiliary ventilation. Approximately 100
dairy cows were housed in individual stalls, with sawdust bedding, at the time of each
sampling event. Air samplers were tethered from stands, which were placed in empty
animal stalls in the center of the building. Area samples of PM were collected
continuously over periods ranging from one to five days. Five independent sets of PM
samples were collected from a series of sampling events in December of 2013 and
August of 2014. On two occasions, triplicates samples were collected in parallel for each
of three size fractions that were investigated.
!
! 50
Ambient PM from Baltimore city was sampled from an urban fourth-floor rooftop
location in July of 2014. Samplers were operated continuously over four to five day
periods to collect sufficient quantities of PM for analysis. One set of triplicate samples
(sampled in parallel) and four additional independent samples (collected in series) for
each size fraction were collected from this environment.
3.3.2. PM Sampling
Samples of inhalable PM were collected on pre-weighed non-pyrogenic 25-
millimeter (mm) polytetrafluoroethylene (PTFE) filters with a 3-micrometer (µm) pore
size (Pall Corporation, Port Washington, NY, USA), using SKC Button Samplers (SKC
Model 225-360, SKC Inc., Eighty Four, PA, USA). Similarly, the thoracic particle
fraction was sampled using SKC Disposable Parallel Particle Impactors (Catalog # 225-
3861, SKC Inc., Eighty Four, PA, USA) and 37 mm PTFE filters with 2 µm pore size.
The respirable size fraction of PM was sampled using BGI Triplex cyclones (Model SCC
1.062, BGI, Waltham, MA, USA) and 37 mm PTFE filters.
All samples were collected using BGI 400 Personal Sampling Pumps, which were
calibrated to the specified flow rates using a BIOS Drycal primary standard (Bios Intl.,
Lakewood, CO, USA) and manufacturer supplied calibration caps or a plastic calibration
jar (Model 225-111, SKC Inc.). To evaluate quality control during the field sampling,
field blanks for all size fractions sampled were included at each sampling event. After
field sampling, all filters were transported directly to JHSPH labs, where they were
aseptically placed in sterile polystyrene petri dishes and stored in a temperature and
humidity controlled room to condition for gravimetric analysis. Filters were weighed
before and after each sampling event with a Mettler Toledo XP2U microbalance (Mettler
!
! 51
Toledo, Columbus, OH, USA), which was sensitive to the tenth of a microgram (µg). All
samples were allowed to equilibrate in the balance room for a 24-hour period before
being weighed. Following gravimetric analysis, these samples were stored in a -20°C
freezer until further use.
3.3.3. Preparation of PM Extracts
To extract stimuli and particles from filter membranes, samples were thawed from
-20°C at room temperature and aseptically inserted into sterile glass vials (Catalog #
SV1020, Allergy Labs, Oklahoma City, OK, USA) under a laminar-flow hood. Filters
were then submerged in 10 mL of sterile, pyrogen-free water (PFW) (Catalog #25-055,
Corning Cellgro, Manssas, VA, USA), which contained 0.05% Tween20 by volume
(Catalog # BP337-500, Thermo Fisher Scientific, Rockville, MD, USA). Each vial was
sealed and then placed on an orbital shaker, set to operate at 250 rpm for 60 minutes, at
20°C. Afterwards, samples were sonicated in a room temperature water bath (Aquasonic
Model 250HT, VWR International, West Chester, PA, USA) of deionized water for 60
minutes (without heat) at 60 hertz. The samples were then removed from the water bath
and mixed vigorously for one minute.
Once the sonicated PM extracts had cooled to room temperature, the extracted
material was suspended by vigorously mixing for one minute, once again. One-milliliter
aliquots of samples were prepared in sterile 1.5 ml microcentrifuge tubes (Catalog #05-
408-129, Thermo Fisher Scientific). One set of aliquots was then centrifuged at 1,000x g
for 15 minutes to remove the insoluble particles in the suspension. Seven hundred and
fifty microliters of particle-free supernatant from the PM extract was carefully withdrawn
!
! 52
and transferred to a new set of sterile 1.5 ml microcentrifuge tubes. All 1 ml and 750 µl
samples were frozen at -80° C until further testing.
3.3.4. Endotoxin Testing
The endotoxin content of the water-soluble fraction of each PM extract was
quantified via a kinetic chromogenic LAL test (Associates of Cape Cod, E. Fallmouth,
MA, USA), following the manufacturer’s protocol. Sample extracts were tested in
technical duplicate, using a series of 10-fold dilutions ranging from 1:1 to 1:1,000. Ten
percent of samples were spiked with control standard endotoxin to a concentration of 0.5
EU/ml, in order to assess for assay inhibition. Purified endotoxin from Escherichia coli
O113:H10 (Lot #249020, Associates of Cape Cod Inc.) and sterile endotoxin-free water
(Catalog #25-055, Corning Cellgro, Manssas, VA, USA) served as positive and negative
controls, respectively.
Each assay included a five-point series dilution of the control standard endotoxin
(concentrations of 50, 5, 0.5, 0.05, and 0.005 EU/ml). Media blanks and field blanks were
included in the extraction and LAL testing as well. The limulus lysate (Pyrochrome® Lot
#2041204, Associates of Cape Cod Inc.) was reconstituted with the manufacturer-
supplied buffer (Glucashield® Lot #1207034, Associates of Cape Cod Inc.), which
served to protect against false positive responses that may result from β-glucans present
in the sample matrix. The limit of detection (LOD) for the test was 0.027 EU/ml and
samples with endotoxin content below the LOD were assigned a value of ½ the LOD
(Adams, 1997).
!
! 53
3.3.5. Whole Blood Collection & Cryopreservation
The WBA used for this study is based on protocols described in detail by
Daneshian et al. (2009) and Schindler et al. (2004), (2006). Blood donations were
collected from consenting healthy adult participants in the JHSPH community, who were
enrolled after they provided an informed oral consent and self-reported to be free from
clinically diagnosed allergy, recent or ongoing infections (bacterial, viral, or parasitic),
pregnancy, and use of prescribed anti-inflammatory or immunomodulatory drugs.
Venous whole blood was collected from participants by a certified phlebotomist, using
sterile sodium-heparin blood collection tubes (Catalog #367874, Becton Dickinson,
Franklin Lakes, NJ, USA). Random samples of these blood collection tubes were pre-
tested to ensure they were free of pyrogenic contamination and did not stimulate the
spontaneous release of IL-1β (data not shown here). All blood samples were stored at
room temperature (out of direct light), until processing for cryopreservation, which was
initiated within one hour of the initial blood draw.
Equal volumes of individual donor blood was pooled into sterile 50 ml
polypropylene conical tubes and gently mixed. Cryopreservation-grade Dimethyl
Sulfoxide (Catalog #BP231-100, Thermo Fisher Scientific) was then slowly added to a
final concentration of 10% (v/v) with constant rotation of the tube. Pooled blood was
immediately aliquoted to pre-cooled (0°C) sterile 5 ml and 2 ml cryovials (Catalog #10-
500-26/27, Thermo Fisher Scientific), which were then kept in an ice water bath for an
additional 15 minutes. The blood was then transferred to a -20°C freezer and cooled for
20 minutes at an approximate rate of 1°C per minute. Lastly, the blood was transferred in
!
! 54
a pre-cooled Styrofoam box to a -80°C freezer for storage. Aliquots were removed and
thawed as needed for incubations.
3.3.6. Whole Blood Assay
Aliquots of PM extract were removed from -80°C freezer and thawed at room
temperature. Each PM extract was vigorously mixed and serial dilutions were prepared
with pyrogen-free water in sterile glass vials. PM extracts (with and without insoluble
particles) were incubated with cryopreserved whole blood and cell culture medium in 1.5
ml sterile polypropylene microcentrifuge tubes (Thermo Fisher Scientific). These
incubation vessels were first prepared with 100 µl of diluted PM extract and 1 ml of
sterile RPMI 1640 (w/L-Glutamine) (Catalog #11875-093, Life Technologies, Grand
Island, NY, USA), after which 100 µl of thawed cryopreserved blood was added. A
subset of incubations were prepared to include Polymyxin B Sulfate, at a final
concentration of 10 µg/ml. Polymyxin B Sulfate is an established endotoxin inhibitor
(Xgen Pharmaceuticals, Big Flats, NY, USA) (Cavaillon & Haeffner-Cavaillon, 1986),
and pilot tests at this concentration sufficiently inhibited the IL-1β cytokine response to
the control standard endotoxin at concentrations up to 10 EU/ml, without inducing cell
death. All sample extracts tested with Polymyxin B were diluted to an endotoxin content
of 10 EU/ml, or less (as measured by LAL analysis) prior to testing.
To inhibit endotoxins in the sample extracts, Polymyxin B was pre-incubated with
the extract and cell culture medium in the incubation vessel at 37°C for 60 minutes. To
maintain continuity in incubation conditions, all samples without Polymyxin B were
similarly pre-incubated. At the end of the pre-incubation phase, cryopreserved whole
blood was removed from the -80°C freezer and rapidly thawed in a 37°C water bath. One
!
! 55
hundred microliters of thawed blood was then added to each 1.5 ml microcentrifuge tube
containing the stimuli and RPMI. These incubation vessels were closed, gently inverted
twice to mix blood with the cell culture medium, and then placed into a humidified
incubator at 37°C and 5% CO2. After 18 hours, the samples were removed from the
incubator and inverted once more to mix cytokines in the solution. These incubations
were either aliquoted and immediately frozen at -80°C for future analysis, or centrifuged
at 10,000 x g for two minutes and tested immediately via ELISA.
Serial dilutions of the PM extracts were tested in the WBA to determine the
lowest extract concentration that elicited an IL-1β response equivalent to a 0.5 EU/ml
concentration of endotoxin. These sample responses were carried forward for further
quantitative analysis. Ten percent of the PM extracts were spiked with 0.5 EU/ml
dilutions of endotoxin to assess for assay inhibition. Purified control standard endotoxin
(Associates of Cape Cod Inc., East Fallmouth, MA) served as the positive control for the
WBA and was matched to the same batch used for the LAL analysis described above.
PFW, PFW and Tween20, and RPMI were included in incubations as negative controls.
All samples were incubated in triplicate for this analysis.
3.3.7. Cytokine Measurement
IL-1β release from each whole blood incubation was quantified with an in-house
sandwich ELISA, using commercially available antibody pairs against human IL-1β
(Catalog # MAB601 and BAF201, R&D Systems, Inc., Minneapolis, MN, USA) and flat-
bottom 96-well NUNC™ Maxisorp® ELISA plates (Thermo Fisher Scientific). The cell-
free supernatant of all incubations were tested in the ELISA in technical duplicate and
results were quantified in picograms (pg) of IL-1β per ml of cell-free supernatant. The
!
! 56
biotinylated secondary antibody was detected with a streptavidin phosphatase enzyme
(Catalog #15-30-00, KPL, Kirkegaard & Perry Laboratories Inc., Gaithersburg, MD,
USA) and BluePhos® Microwell Substrate System (Catalog #50-88-00, KPL).
Recombinant IL-1β from R&D Systems (Catalog # 201-LB) served as positive control
for the assay. The lower limit of sensitivity of the ELISA was 3.9 pg/ml.
3.3.8. Statistical Analysis
Exploratory data analysis and descriptive statistics were completed using the
software package GraphPad Prism 6.0 (GraphPad Software Inc., San Diego, CA). IL-1β
cytokine responses from the WBA were converted to units of “Equivalent Endotoxin
Units” (EEU) for all statistical analysis, in order to compare LAL and WBA results using
comparable units. A 4-PL logistic curve was fit to IL-1β cytokine responses that were
developed from dose-response experiments using an eight-point series dilution of
endotoxin standards (0.1 EU/ml – 10 EU/ml).
The mean IL-1β responses from triplicate incubations of PM extracts were
referenced against the logistic curve-fit to determine the concentration of endotoxin that
was necessary to elicit an equivalent IL-1β response. The result provided an estimate of
each sample’s potency, relative to that of the endotoxin used as a positive control for both
the LAL and WBA testing. For reference, 1 endotoxin unit (EU) is defined as 100 pg of
purified LPS from the WHO reference strain of E. coli (O113:H10) (Poole et al., 1997).
Thus, 1 EU/m3 and 1 EEU/m3 represent a burden of stimuli equivalent to approximately
100 pg of the WHO reference standard endotoxin per cubic meter of air.
Concentrations of endotoxin (EU) and equivalent endotoxin stimuli in the PM
extracts were normalized to units of PM mass (EU or EEU/mg) and to units of air
!
! 57
sampled (EU or EEU/m3). Normality of the data was assessed with a Shapiro-Wilk test
and non-normal data was log-transformed. Statistical comparisons between groups of
samples from different environments or different particle size fractions were completed
with un-paired, two-tailed Student’s t-tests. A one-way ANOVA with Dunnett’s post-test
was used for multiple comparisons to a reference or control group.
Paired Student’s t-tests was used to assess whole blood incubations that were
completed using extracts with and without insoluble particles, and extracts with and
without the endotoxin inhibitor. Paired, two-tailed t-tests were used to determine the
difference between LAL and WBA tests of the same extract, or WBA tests of extracts
with and without insoluble particles, or tests with and without the endotoxin inhibitor.
Rank-order Spearman correlations were calculated to assess agreement between the LAL
and WBA responses to PM extracts. The normality of the data set used for correlation
analyses was assessed with the Shapiro-Wilk test. A p-value = 0.05 was defined at the
threshold of statistical significance for all statistical analyses.
!
! 58
3.4. Results
3.4.1. Environmental PM Concentrations
In this study, size-selective PM samplers were used to collect PM from the indoor
air of two broiler poultry houses and two comparison environments (a dairy cow barn and
Baltimore City). The respirable, thoracic, and inhalable particle size fractions were
simultaneously sampled in each environment to evaluate the relative burden of particle
mass and stimuli in the air. These particle size classifications represent different fractions
of particles that are capable of depositing in specific zones of the respiratory tract
(Cherrie & Aitken, 1999). Inhalable PM contains the fraction of airborne particles that
are capable of entering the nasal passages and depositing throughout the respiratory tract.
The thoracic size fraction is a subset of inhalable PM, and correlates with particles that
are capable of depositing in the tracheobronchial region, or further in the peripheral lung.
The median aerodynamic equivalent diameter (AED) of these particles is approximately
10 µm. The respirable fraction of particles is limited to those which are sufficiently small
in diameter to travel beyond the conducting airways and deposit in the gas exchange
regions of the lung. The median AED of respirable PM is four µm.
All PM samples were collected on non-pyrogenic PTFE filter membranes, which
were weighed for gravimetric analysis and then processed to evaluate the respective
content of endotoxin (using the LAL test), and equivalent endotoxin stimuli (using the
WBA). Table 3.1 summarizes the average concentrations of PM mass and stimuli present
in the air of each of the three sampling environments. Data for the broiler poultry
environment reflects five independent sampling events completed in two houses over the
final three weeks of the broiler growth cycle.
!
! 59
As expected, average concentrations for all particle size fractions in the indoor air
of the poultry houses were significantly greater than concentrations measured in the open
air of the dairy barn and ambient air of Baltimore City. Consequently, these poultry
houses also exhibited markedly higher concentrations of endotoxin and equivalent
endotoxin stimuli than the other environments. While the respirable fraction of particles
comprised 18% of the inhalable poultry PM mass, on average, it represented only 10% of
the total inhalable endotoxins there were measured via the LAL testing, and less than 2%
of the pro-inflammatory signal from the WBA. Thus, a comparatively small fraction of
the inhalable endotoxin and stimuli in poultry house air was capable of traveling into the
peripheral regions of the lung. A large amount of this pro-inflammatory stimulus is likely
to deposit in the nasopharyngeal region of the respiratory system.
On average, thoracic diameter PM accounted for nearly 67% of mass in the
inhalable fraction of PM from the poultry house with, and carried 42% of the respective
endotoxin content, and less than 20% of the total pro-inflammatory signal in the WBA.
More than half of the inhalable endotoxins, and over 80% of the pro-inflammatory signal
of the inhalable poultry PM was associated with particles of extrathoracic diameter.
However, there remains a notable burden of the endotoxin and pro-inflammatory stimulus
that may be inhaled and deposited on surfaces of the conducting airways, where it is
likely to be removed via the mucociliary clearance tract or by cellular phagocytosis.
!
! 60
Table 3.1. Average concentrations of PM, endotoxin, and equivalent endotoxin
stimuli in the air of each sampling environment
Broiler Poultry House
GM (95% CI)
Dairy Barn
GM (95% CI)
Baltimore City
GM (95% CI)
N = 5c N = 5 N = 5
PM Concentration (µg/m3)
Inhalable 1,587 (927 – 2,719)*** 18 (6 - 54) 11 (7 - 20)
Thoracic 1,074 (784 – 1,417)** 16 (10 - 26) 12 (11 - 14)
Respirable 285 (109 – 745) 10 (6 - 18) 10 (8 - 12)
Endotoxins (EU/m3)
Inhalable 1,309 (858 – 1,997)*** 13 (5 – 35)*** 1.0 (0.3 – 2.8)*
Thoracic 548 (411 - 729)*** 6 (4 – 10)** 0.4 (0.2 – 1.0)
Respirable 129 (74 - 226) 1 (0.8 – 2) 0.3 (0.2 – 0.4)
Equivalent Endotoxins (EEU/m3)
Inhalable 3,317 (1,512 – 7,278)*** 18 (13 -27)*** 0.3 (0.2 – 0.6)
Thoracic 583 (370 - 918)** 15 (7 – 28) *** <LOD
Respirable 53 (13 - 216) 3 (1 – 7) <LOD
a Geometric Mean (GM) of five independent samples with 95% confidence interval (CI)
b One-way ANOVA with Dunnett’s Post-tests used to assess equality of means across size fractions within
each environment. Respirable PM was treated as reference group for all comparisons. Statistical
significance: * p<0.05, ** p<0.01, ***<0.001 indicates difference from reference group.
c N = 4 for thoracic poultry PM.
!
! 61
In contrast to the broiler poultry environment, over 50% of the mass of PM in the
air of the dairy barn was attributed to respirable diameter particles, with the remainder
allocated to the thoracic size fraction. In a manner similar to the poultry PM, the burden
of endotoxin and equivalent endotoxin stimuli was greatest in the largest particle size
fractions. Lastly, PM in the ambient air of Baltimore City consisted almost entirely of
respirable particles, which carried a minimal burden of pro-inflammatory stimuli.
While these measures illustrate the differences in potential exposures between
environments, broiler poultry houses are dynamic environments, where environmental
factors (e.g. - feed, temperature, bird weight and activity) may change significantly over
time. Therefore, we sampled PM periodically over the course of a flock’s growth cycle in
Poultry House B to investigate the variability in concentrations of PM and pro-
inflammatory stimuli over time. This house was sampled while it contained a flock of
2,000 birds and results of the sampling are summarized in Figure 3.5.
In poultry house B the average background concentrations of inhalable, thoracic,
and respirable PM were 27 µg/m3, 21 µg/m3, and 19 µg/m3, respectively. Over the course
of the flock’s 42-day growth cycle, the indoor air concentrations of PM mass, endotoxin,
and equivalent endotoxin stimuli increased significantly and were evident in each of the
three particle size fractions sampled. The pro-inflammatory stimuli and particle mass
associated with the respirable fraction of PM in the indoor air increased the least of the
three particle size fractions we investigated. Together, these results describe the dynamic
environmental conditions within the indoor air of broiler poultry houses over the duration
of a flock’s growth cycle, and indicate that worker exposures to aerosolized PM and pro-
inflammatory stimuli may change significantly as the flock ages. These changing
!
! 62
conditions should be taken into account when assessing occupational exposures in these
environments.
Figure 3.5. Indoor air concentrations of PM (A), endotoxins (B), and equivalent
endotoxin stimuli (C) increase significantly for each of the respirable, thoracic, and
inhalable particle size fractions over the 42-day broiler flock growth cycle.
!
! 63
3.4.2. Endotoxin & Equivalent Endotoxin Stimuli per Unit Mass of PM
While concentrations of PM and pro-inflammatory stimuli per unit volume of air
in these sampling environments varied considerably, the relative potency of stimuli per
unit of PM mass was also considered. Table 3.2 summarizes measures of pro-
inflammatory burden in EU/mg and EEU/mg for the respirable, thoracic, and inhalable
size fractions of PM from each sampling environment.
On a unit mass basis, the burden of endotoxin and equivalent endotoxin stimuli in
poultry and dairy PM were similar in magnitude, yet were distributed differently amongst
the size fractions of particles. The pro-inflammatory potential per unit mass of respirable
and thoracic dairy PM exceeded that of the poultry PM. The results also suggested that
the LAL test underestimated the total pro-inflammatory potential of dairy PM at nearly
all size fractions, and underestimated the potency of stimuli in the inhalable poultry PM.
To assess the relative agreement between measures of the LAL test and the WBA,
the PM extract data from all environments and size fractions were pooled (N = 45) and a
rank-order Spearman correlation coefficient was computed. Spearman’s rho, comparing
the LAL-derived EU/mg with the WBA measure of EEU/mg, was calculated to be 0.89
(95% CI: 0.79 – 0.94, p<0.001). To evaluate whether the endotoxin content of PM varies
with the growth cycle of the flock, the endotoxin content of samples from Poultry House
B were normalized to units of PM mass and are summarized in the Figure 3.6, which
depicts the mean and standard deviation of triplicate samples from sampling date. No
endotoxin data were available for background levels of thoracic PM.
The endotoxin content per unit mass of this PM varied over time and was greatest
at day 22 of the flock’s growth cycle. Endotoxins in the inhalable particle size fraction
!
! 64
increased by a factor of 12 over the background content during the first three weeks of
the flock’s growth cycle (Background 99 EU/mg, Day 22: 1197 EU/mg). Similarly, the
endotoxin content of Respirable PM tripled in the first three weeks (Background: 260
EU/mg; Day 22: 793 EU/mg). Surprisingly, no difference in endotoxin content per unit
mass of PM was observed between the respirable and thoracic fractions.
Table 3.2. Pro-inflammatory signal, per unit mass PM from poultry house, dairy
barn, and urban Baltimore City environments
PM Size
Fraction
Broiler Poultry House
GM
(95% CI)
Dairy Barn
GM
(95% CI)
Baltimore City
GM
(95% CI)
n = 5 n = 5 n = 5
EU/mg EEU/mg EU/mg EEU/mg EU/mg EEU/mg
Inhalable 801*
(592 – 1,083)
1,940 ***
(1,387 – 2,712)
726***
(571 - 922)
872*
(490 - 1550)
41 ***
(19 - 88)
28***
(20 – 38)
Thoracic 514
(371 - 712)
569
(384 - 843)
394***
(305 - 508)
909*
(537 - 1541)
34
(16 - 74)
<LOD
Respirable 378
(188 - 759)
138
(46 -416)
116
(47 - 285)
268
(166 - 431)
19
(13 -30)
<LOD
LOD = Limit of Detection
a Geometric Mean (GM) of five independent samples with 95% confidence interval (CI)
b One-way ANOVA and Dunnett’s Post-test were used to assess equality of means for EU/mg & EEU/mg,
within environments, with respirable PM as a reference category for multiple comparisons. Statistical
significance: * p<0.05, ** p<0.01, ***<0.001 indicate significant difference from reference group.
!
! 65
Figure 3.6. Endotoxin content per unit mass of PM in Poultry House B varies over
the growth cycle of the flock.
3.4.3. WBA Response to Particle-free Extracts
One key factor that may influence the results of LAL is the requirement to remove
insoluble particles from samples prior to testing, in order to mitigate sources of
interference in the assay. Since the WBA carries the flexibility to test samples containing
solid particles, we chose to incubate air sample extracts both with (+), and without (-), the
insoluble fraction of PM. The three particle size fractions tested here were simultaneously
sampled in each environment (Poultry House A and the dairy barn). PM extracts were
incubated in triplicate with cryopreserved whole blood and Figure 3.7 summarizes the
average burden of stimuli per milligram of PM.
!
! 66
Figure 3.7. Insoluble particles contribute to pro-inflammatory potential of poultry
and dairy PM extracts.
The WBA testing of this PM indicated a qualitative reduction in the pro-
inflammatory potential associated with the removal of insoluble PM from nearly all
extracts tested. Statistically significant reductions in potency were recorded for particle-
free extracts of thoracic PM from both the dairy and poultry environments. At the
respirable PM size fraction, the removal of insoluble particles from poultry and dairy
samples did not attenuate the respective potencies, suggesting that stimuli in this size
fraction may have been predominantly water-soluble. It is also notable that the same
trend of increasing pro-inflammatory potential across the respirable, thoracic, and
inhalable PM extracts is evident, whether particles were included in the incubation or not.
!
! 67
3.4.4. Endotoxin-inhibition Tests
Next, we sought to investigate how much of the total pro-inflammatory potential
of this PM was mediated by endotoxin. Since the inhalable and thoracic PM samples
from the poultry house and dairy barn exhibited the highest pro-inflammatory potential, a
subset of these extracts was incubated with cryopreserved whole blood and an endotoxin
inhibitor (Polymyxin B). Triplicate samples of each particle size fraction were again
chosen for this analysis to minimize potential environmental variability. All extracts were
incubated in triplicate and IL-1β release was measured following stimulation.
For all samples tested with Polymyxin B, the IL-1β signal was reduced, and a
significant signal from non-endotoxin stimuli remained. For PM from poultry house A,
the incubation of sample extracts with Polymyxin B suggested that non-endotoxin stimuli
accounted for 52% of the total IL-1β-inducing capacity of inhalable PM. Similarly, non-
endotoxin stimuli represented 60% of the total IL-1β signal for the thoracic fraction of
this poultry PM. In dairy PM, non-endotoxins mediated a lower proportion of the pro-
inflammatory signal, accounting for 26% and 21% of the IL-1β response in the inhalable
and thoracic fractions, respectively.
For samples from each environment, a strong residual inflammatory cytokine
response remained after endotoxin activity was inhibited in the sample. We conducted
preliminary testing in our lab to verify that the final concentration of Polymyxin B used
for these incubations was sufficient to block response to stimulation with control standard
endotoxin at concentrations up to 10 EU/ml. In these tests, endotoxin activity was
abrogated without significantly inhibiting IL-1β responses to non-endotoxin stimuli, such
!
! 68
as LTA (data not shown here). Thus, for this testing, all PM extracts were diluted in PFW
to endotoxin concentrations less than 10 EU/ml.
Table 3.3. Reductions in pro-inflammatory signal following inhibition of endotoxin
in PM extracts with Polymyxin B
PM Size
Fraction
Poultry House (EEU/mg)
Mean (SD)
Dairy Barn (EEU/mg)
Mean (SD)
PM
Extract
PM Extract
+
Polymyxin B
Non-
Endotoxin
Signal
(% of Total)
PM
Extract
PM Extract
+
Polymyxin B
Non-
Endotoxin
Signal
(% of Total)
2,950
(587)
1,514**
(194)
51%
1,655
(150)
435*
(88)
26% Inhalable
(N = 3)
492
(52)
293*
(28)
60%
1,187
(354)
246**
(38)
21% Thoracic
(N = 3)
a Mean (SD) of triplicate samples
b Paired Student’s t-test to assess equality of means for samples tested with and without endotoxin inhibitor
Statistical significance: * p<0.05, ** p<0.01.
!
! 69
3.5. Discussion
The research present here is one of a small number of studies that have used a
human WBA to investigate the total pro-inflammatory potential of air samples (Liebers et
al., 2009; Zucker et al., 2006; Kindinger et al., 2005) It is the first to use a cryopreserved
WBA model to evaluate the pro-inflammatory potential of poultry PM from the
inhalable, thoracic, and respirable particle size fractions and contrast it with PM from
non-poultry environments. This research also conducted endotoxin testing of this PM
with a kinetic chromogenic LAL test. While elements of the study support the utility of
endotoxin analysis in exposure assessment, they also highlight key limitations associated
with LAL testing that may lead to exposure misclassification in some environments.
The results of this study demonstrate that poultry house PM carries a complex and
dynamic burden of constituents, which are capable of stimulating the release of
conserved inflammatory mediators from the human innate immune system. Although
bacterial endotoxins contribute significantly towards the pro-inflammatory potential of
this PM matrix, other non-endotoxin stimuli are present and likely act in concert with
endotoxin during exposures to promote respiratory inflammation. The presence of this
non-endotoxin stimuli is further supported by a number of poultry house exposure
assessment studies, which have characterized the diverse populations of Gram-positive,
Gram-negative, and fungal microbes that inhabit these environments and serve as sources
of biogenic PM constituents (Lawniczek-Walczyk et al., 2013; Rylander & Carvalheiro,
2006; Viegas et al., 2012). The immunogenic properties of this PM continue to suggest
that traditional mass-based exposure metrics are inadequate proxies for pro-inflammatory
potential (Cherrie et al., 2013; Poole & Romberger, 2012). Similarly, the quantification
!
! 70
of endotoxins in PM has provided a narrow and incomplete evaluation of total pro-
inflammation potential in agricultural PM (Poole et al., 2010).
The inhalable, thoracic, and respirable PM size fractions were sampled for this
study in order to quantify and communicate contaminant concentrations under a
framework consistent with standard occupational hygiene practice. In the US, the
Occupational Health and Safety Administration (OSHA) enforces workplace exposure
limits and has classified poultry PM as “Particles Not Otherwise Regulated” (PNOR).
This classification is customarily reserved for dusts considered to be inert and innocuous.
PNOR is associated with permissible exposure limits (PEL) of 15 mg/m3 for total dust
(roughly equivalent to the inhalable fraction) and 5 mg/m3 for the respirable fraction.
The poultry PM concentrations reported in this study are well below the
applicable OSHA PELs and are on the low end of concentrations reported in recent
review by Basinas et al. (2013) and a multi-farm study by Kirychuk and colleagues
(2006), who assessed PM concentrations in 30 layer and 30 broiler poultry houses in
Canada. Collectively, this literature describes average concentrations of inhalable PM in
broiler houses within a range of 1.1 mg/m3 to 24.2 mg/m3. Similarly, the respirable
fraction of PM is reported at concentrations ranging from 80 µg/m3 to 4.20 mg/m3. Thus,
there is considerable variability in conditions across different poultry house
environments. In the present study, the average inhalable PM concentration in these
poultry houses was 1.59 mg/m3, with respirable PM concentrations were measured at 290
µg/m3. Although the broiler research houses used for this study were significantly smaller
in scale that industrial houses, they fostered concentrations of PM that were within the
range of that reported from industrial houses.
!
! 71
Donham and colleagues (2000) have proposed specific threshold exposure limits
of 2.4 mg/m3 and 160 µg/m3 for occupational exposures to inhalable and respirable
poultry PM. These concentrations were interpreted as a threshold at which poultry
workers were observed to experience a 3% or greater cross-shift decline in FEV1, a
measure of lung function in the small airways. In our study, average concentrations of
inhalable PM were below these suggested limits, while respirable PM was measured at
concentrations 1.8 times greater than the corresponding threshold. The concentrations of
PM at the dairy barn and in Baltimore City, which serves as source of PM for comparison
purposes, were at least an order of magnitude lower than that of the poultry house.
LAL analysis of these samples indicated that PM from the dairy barn carried a
burden of endotoxin that was similar to that of poultry PM, when normalized to units of
PM mass. However, by virtue of the high particle mass concentrations in the air at the
respective environments, the poultry house represented markedly higher levels of
exposure to pro-inflammatory stimuli. Although there are no formal occupational limits
or guidelines for endotoxin exposure in the workplace, threshold exposure limits have
been proposed for poultry workers by Donham and colleagues (total dust: 614 EU/m3;
respirable PM: 0.32 EU/m3). The Dutch Expert Committee on Occupational Safety
(DECOS) has also proposed guidelines of 90 EU/m3 (inhalable dust) for general
occupational endotoxin exposures (DECOS, 2013). Notably, the DECOS
recommendation does not further differentiate exposure limits by PM size fraction.
The average concentration of inhalable endotoxins in these poultry research
houses was over twice the suggested limits of Donham and colleages, and over 17 times
greater than the DECOS limit. Less than half of this inhalable endotoxin was associated
!
! 72
with thoracic particles that could travel into the conducting and peripheral airways. For
endotoxin in the respirable fraction of poultry PM, the results of this study exceeded the
recommendations of Donham and colleagues by a factor of 400. We also note that this
limit was surpassed by endotoxin concentrations at the dairy barn, despite PM mass
concentrations that were similar to that of ambient air in Baltimore City.
The influence of animal activity has a pronounced effect on endotoxin content at
all particle size fractions. The varied distribution of pro-inflammatory stimuli in these
particle size fractions is most evident in the series of sampling events conducted in
Poultry House B. Here, the concentration of PM and endotoxin changed significantly
over the flock’s growth cycle, and changes were not solely attributable to mass
concentrations of PM in the air. The trend was partly associated with a decrease in the
endotoxin content per unit mass of this PM, suggesting that influence of Gram-negative
bacteria on poultry PM varies over time.
When samples for this study were evaluated as a function of their capacity to
elicit to the release of IL-1β in the cryopreserved WBA, the respective potencies were
quantified in a metric of “equivalent endotoxin units”. Thus, the aggregate pro-
inflammatory burden of stimuli in any given PM sample was expressed on a scale relative
to the pro-inflammatory potency of a common reference E. coli endotoxin. This
endotoxin served as a positive control in both the LAL and WBA tests. Results of the
WBA testing revealed a number of trends across samples that were generally consistent
with the endotoxin analysis, with added insight towards to the pro-inflammatory
influences of non-endotoxin stimuli in this PM.
!
! 73
One interesting deviation between the results of the WBA and LAL test was
related to the relative difference in pro-inflammatory signal between the respirable,
thoracic, and inhalable particle size fractions. To illustrate this point, the LAL-measured
endotoxin content of the inhalable poultry PM (801 EU/mg) was twice that of the
respirable PM (378 EU/mg) (see Table 3.2). However, the WBA testing indicated the
inhalable PM signal (1,910 EEU/mg) was 14 times greater than that of the respirable
fraction (138 EEU/mg), for these same samples. Such discrepancies in response may be
attributed to a variety of factors, which include: 1) the WBA’s capacity to detect
endotoxin with a greater range of sensitivity (Brandenburg et al., 2009; Dehus et al.,
2006), 2) to respond to non-endotoxin stimuli (Deininger et al., 2008; Hasiwa et al.,
2013), and 3) to test complex mixtures of soluble and insoluble PM constituents
(Kindinger et al., 2005).
The contribution of the insoluble particles to the WBA signal was specifically
investigated in this study, since their removal is required for endotoxin testing in the
kinetic chromogenic LAL. The WBA cytokine response to the inhalable and thoracic PM
samples was enhanced when PM extracts were tested with insoluble particles, as opposed
to when they were tested after centrifugation. The findings of this study indicate that a
non-trivial amount of pro-inflammatory stimuli is removed from the sample prior to LAL
analysis. This is a potentially important source of stimuli in biogenic PM exposures as
insoluble constituents may be cleared from the respiratory system at a different rate and
through different mechanisms than water-soluble constituents (Geiser & Kreyling, 2010).
We also investigated the degree to which endotoxin mediates the pro-
inflammatory potential of this PM in the WBA. Polymyxin B was used to inhibit the
!
! 74
activity of endotoxin in PM extracts and significant reductions in WBA signal were
evident for all samples tested. Similar findings have been reported by Poole et al. (2010)
who stimulate peripheral blood monocytes (PBMC) with dust extracts from a variety
agricultural environments (i.e – swine, dairy, grain). In this study, the authors similarly
treated extracts with Polyxmyxin B, and found that it did not completely abrogate the
release of TNFα, IL-6, and IL-8 from stimulated PBMC cultures. The residual response
was partly attributed to muramic acid (a marker of peptidoglycans) and ergosterol (a
marker of fungal biomass). This again illustrates the sources of pro-inflammatory stimuli
in this PM that are not captured by standard LAL testing.
However, we also note that when the results of the LAL and WBA analyses are
assessed via a non-parametric correlation, there remains a strong agreement between the
two assays with regards to the ranking of samples based on pro-inflammatory signal
(Spearman’s Rho = 0.89, p<0.001). Liebers et al. (2009) and Zucker et al. (2006)
completed similar studies of air samples using both LAL and WBA tests and report
similar agreement between assay responses. It should be acknowledged that LAL testing
remains a staple of bioaerosol assessment and complements the holistic responses
produced by the WBA testing methods.
There are a number of limitations that need to be highlighted. The findings of this
study are based on an assessment of two poultry houses. These samples provide insight
into the distribution and potency of stimuli in the PM, but largely reflect the
environmental conditions of the poultry houses at the time of sampling. In particular, the
sampling conducted in poultry house B supports the dynamism of these environments and
the potential for worker exposures to vary significantly over time. It is important to
!
! 75
understand this variability and clarify how it affects the key particle size fractions in
order to assess how exposures may vary over time, with respect to different regions of the
respiratory system. Sampling conducted across time periods or seasons may yield
different compositions of PM that translate to greater or lesser measures of endotoxin
content and pro-inflammatory potential. A more comprehensive longitudinal assessment
is necessary to further evaluate the influences of key environmental factors and the
variability of the measures over time.
All samples used for endotoxin and WBA analysis in this study represent area
samples of PM, as opposed personal exposure measurements taken directly from
breathing zones of workers. The range of PM concentrations to which a poultry worker
may be exposed to during the course of a work shift may not be the same at that observed
in the stationary time-integrated samples collected for this study. In general, area samples
are though to underestimate personal exposures (Cherrie & Aitken, 1999). Lastly, the
endotoxin and WBA analysis was conducted on aqueous extracts of stimuli prepared
from air filter samples. The efficiency with which stimuli are eluted from air filters into
the extraction medium is not well understood and thus it is possible that the stimuli in the
extract underestimate the true burden of soluble stimuli. Air filter extraction methods for
this study were based on commonly used protocols for endotoxin testing. However, as the
WBA analysis of particle-free extracts indicated, cytokine response is enhanced when the
entire PM matrix (soluble and insoluble) is tested.
The industrialization of the broiler poultry industry has created harsh working
environments where dusts are consistently re-suspended into the air by cycles of animal
activity and facility ventilation. Even in the poultry research facilities sampled for this
!
! 76
study, workers are repetitively exposed to this PM. The evaluation of these exposures and
worker health should account for the complex pro-inflammatory potential of this PM and
the chronic nature of occupational exposure. This study is one of a small number to
assess the total pro-inflammatory potential PM with human WBA methods. Future
studies are needed to develop health-based exposure metrics using the WBA.
!!!
!
! 77
3.6. Conclusions
In conclusion, the findings of this study demonstrate that the quantification of
endotoxin, alone, does not capture the total pro-inflammatory potential of PM from the
broiler poultry house environment. When normalized to PM mass, the larger particle size
fractions carried the greatest burden of endotoxin and the highest capacity to elicit the
release of IL-1β from the cryopreserved WBA. Approximately one-half of this pro-
inflammatory signal was driven by non-endotoxin stimuli, which were not detected via
LAL testing. Additionally, measurable quantities of pro-inflammatory stimuli were
associated with insoluble constituents, which are also not captured by the LAL test.
Broiler poultry houses are harsh occupational environments with high concentrations of
PM that carries a robust pro-inflammatory potential. Although these broiler poultry
research houses were smaller than industrial-scale facilities, the indoor air concentrations
of PM and endotoxin exceeded health-based guidelines that have been proposed for
poultry workers.
Acknowledgements.
The authors are thankful to Dr. Hong Li, Dr. Tanya Gressley, and the University
of Delaware Department of Animal and Foods sciences, who provided access to broiler
poultry houses and the dairy barn used for sampling in this study. J.N. acknowledges the
support of a NIOSH ERC Pilot Project Training Grant, which funded this study, and
USDA NRI project 2008-55112-18761 which provided the flocks of chickens that were
present in these broiler research houses at the time of sampling.
!
! 78
!!!
Chapter 4
Pro-Inflammatory Effects of Traffic PM on Whole Blood
Responses of Asthmatic Peruvian Children
Jesse P. Negherbon
Department of Environmental Health Sciences
Johns Hopkins Bloomberg School of Public Health
615 N. Wolfe St., Baltimore, MD 21205
Keywords: Particulate Matter, Asthma, Endotoxin, Black Carbon, Whole Blood Assay
!
! 79
4.1. Abstract
Exposure to particulate matter (PM) from mobile sources (i.e. – traffic-related
PM) stimulates airway inflammation and may promote asthma in children living near
major highways. However, it is unclear if asthmatics carry increased susceptibility to
traffic PM-induced inflammation. This study used a human whole blood assay (WBA) to
investigate traffic-related PM (TRPM) exposure and innate immune responses among
asthmatic and non-asthmatic children in a peri-urban neighborhood of Lima, Peru.
Asthmatic participants were recruited from residences surrounding a major highway in
the study area. Ambient PM (respirable) was sampled at their homes to assess
environmental exposures to PM, black carbon, and endotoxin. Peripheral whole blood
from 32 asthmatic children and 13 non-asthmatic children was stimulated ex vivo with
endotoxin and local PM. WBA release of the cytokine Interleukin (IL)-1β was quantified
as a marker of inflammatory response. IL-1β responses to stimulation with endotoxin and
PM were not associated with asthma status. However, PM2.5-stimulated WBA responses
were 50% lower for participants living within 75 meters of the study area highway, as
compared to subjects living at distances of 150 meters or more. The study results suggest
that residential proximity to the highway is associated with an attenuated acute-phase
inflammatory cytokine response to TRPM constituents at the systemic level for children
in this community.
!
!
! 80
4.2. Introduction
Asthma is an non-infectious respiratory disease, which is commonly characterized
by recurrent episodes of airway inflammation, bronchial hyperreactivity, increased mucus
production, and airflow obstruction (Diette et al., 2008; Wills-Karp, 1999). Although the
asthmatic disease state is classically associated with atopic phenotypes and sensitization
to aeroallergens, it is estimated that only one-half of asthma cases are mediated by
eosinophilic responses (Pearce et al., 1999). Consequently, there is increasing interest for
the hazards of many non-allergenic environmental agents, which are thought to
exacerbate asthma symptoms by stimulating inflammatory activity from defense
mechanisms of the innate immune system (Alexis & Carlsten, 2014). These exposures
often result in the production of reactive oxygen species and the release of non-specific
inflammatory mediators, independent of an allergic response (DeKruyff et al., 2014;
Simpson et al., 2008).
Traffic-related particulate matter (TRPM) exposures are known to stimulate acute
phase inflammation in exposed airways and are increasingly regarded as environmental
risk factors for asthma (Delfino et al., 2013; Ghio et al., 2012; McCreanor et al., 2007).
Accordingly, multiple epidemiological studies have reported an increased prevalence of
asthma in children who live near major highways, and have associated this elevated risk
with chronic exposure to traffic-related pollutants, including PM2.5 (particles with
aerodynamic equivalent diameters ≤ 2.5 µm) (McConnell et al., 2006; Venn et al., 2001).
Ambient concentrations of PM2.5 and black carbon (BC) (a marker of combustion) often
remain high within 75 – 100 meters (m) of major highways, and decrease to background
levels after distances of 150 – 300 m (Zhu et al., 2002; Hitchins, et al., 2000). The
!
! 81
capacity of these particles to drive respiratory inflammation is regarded as an important
determinant of their potential hazard for susceptible populations since they are capable of
both transporting over long distances in the environment, and depositing in the sensitive
alveolar region of the respiratory system (Pope & Dockery, 2006).
However, the task of evaluating TRPM exposures as a function of their aggregate
pro-inflammatory potential (rather than particle mass) is complicated by the inherently
heterogeneous composition of anthropogenic, biologic, and crustal elements in the PM
matrix (Delfino et al., 2008). Many of these constituents are known to individually
stimulate non-specific inflammation, yet a single component approach to these exposure
assessments remains common practice. The customary methods provide no insight
towards the pro-inflammatory potential of PM constituents that act in concert and often
lack the necessary biologic relevance and standardization to accurately detect and
contrast exposure-response relationships between individuals. Together, these limitations
have contributed to a limied understanding for the relative susceptibility of both
asthmatics and non-asthmatic to TRPM-induced inflammation.
Therefore, this study sought to holistically investigate the potential of TRPM to
induce non-specific inflammatory immune responses in a cohort of asthmatic and non-
asthmatic children from a peri-urban neighborhood of Lima, Peru. To model the interplay
between traffic PM exposure and the innate immune responses of these children, we used
of a human whole blood assay (WBA). This method allowed for peripheral whole blood
from individual participants to be directly challenged, ex vivo, with PM that had been
size-selectively sampled from their local environment.
!
! 82
Chronic exposures to traffic pollution (including PM) are pervasive in Lima and
dense urbanization has rapidly developed on the periphery of the city. Today, Lima is
now an expansive population center with an estimated 8.5 million people. Given that the
country of Peru has the highest reported prevalence of asthma of Latin American
countries, traffic PM exposures may serve as a significant environmental mediator in the
observed asthma morbidity in this population (Mallol et al., 2000).
For this study, the WBA represented a unique field applicable test with which
individual immune responses to standard inflammatory agents and complex
environmental matrices could both be contrasted in order to determine if systemic
susceptibilities were evident between distinct groups of subjects. The human whole blood
system was a fitting reaction medium as it carries an array of immunologic defense
mechanisms (e.g. - innate pattern recognition receptors, complement) that recognize a
wide array of biologically relevant stimuli with exquisite sensitivity (Hasiwa et al., 2013).
The robustness of the assay is attributed, in part, to the use of peripheral whole blood,
which maintains the physiologic composition of the donor whole blood system (e.g. –
leukocyte subpopulations, antibodies, soluble factors), and allows immune cells to
respond to stimuli in their evolved cellular and molecular context (Hartung & Wendel,
1995). Stimulation of whole blood results in a complex inflammatory cascade that
includes the rapid, dose-dependent release of acute phase mediators (e.g. – TNFα, IL-1β,
IL-6) from blood monocytes, increased cellular phagocytic activity, and the production of
reactive oxygen species (ROS) (Takeuchi & Akira, 2010; Mogensen, 2009).
To complete this research, asthmatic and non-asthmatics children from the study
community donated peripheral whole blood, which was incubated under physiologic
!
! 83
conditions with an aqueous particle extract from local air samples of traffic PM2.5 and a
reference endotoxin. Respirable PM was sampled from ambient air of asthmatic
participant homes in order to evaluate ambient concentrations of PM, black carbon (BC, a
marker of combustion), and endotoxin (a potent immunostimulatory molecule from
Gram-negative bacteria). The respirable fraction of particle was sampled for this study, as
opposed to PM2.5, as it more closely encompassed the fraction of particles and stimuli
that were likely to deposit in the peripheral airways of the respiratory tract (Cherrie &
Aitken, 1999). We quantified the capacity of PM and endotoxin to elicit the release of
Interleukin (IL)-1β, a conserved inflammatory cytokine, from donor blood and evaluated
these responses as a function of participant asthma status and residential proximity to a
major highway in the study area.
!
! 84
4.3. Materials and Methods
4.3.1. Ethics Statement
The Institutional Review Boards of the Johns Hopkins University (JHU) School
of Medicine (Baltimore, MD, USA) (Study # CIR00007480) and A.B. PRISMA (Lima,
Peru) approved this study. Written informed consent for participation was obtained from
the parents or guardians of each participant. It was also assured that participants,
themselves, were in agreement to partake in the study.
4.3.2. Study Site & Population
This study was conducted in Pampas de San Juan de Miraflores, a peri-urban
neighborhood located 25 kilometers south of central Lima, the capitol and economic
center of Peru. The Pampas community encompassed a dense population of
approximately 60,000 people and primarily consisted of low-to-middle income
households (Robinson et al., 2012). A four-lane paved highway bisected the study area,
and small single or double lane collector streets (both paved and unpaved) permeated the
surrounding community (see Figure 4.1). This main highway was heavily trafficked by
commuter buses, freight trucks, and taxis, which served as the primary sources of
combustion pollutants in local ambient air.
!
! 85
Figure 4.1. Study area limits in the neighborhood of Pampas de San Juan de
Miraflores in Lima, Peru
Preliminary air sampling in Pampas showed that ambient concentrations of PM2.5
and BC were twice as high within 50 m of the highway, as compared to distances of 200
m or more (data not shown here). Baumann and colleagues (2011) conducted
epidemiological investigations in this community, and reported that children residing in
households within 100 m of the highway in the study area (shown in Figure 4.1) had
twice the odds of reporting current asthma symptoms, as compared to children living at
distances of 384 m or further.
!
! 86
The present study enrolled three groups of children from Pampas, and recruited
participants from the cohort of an on-going longitudinal study that examined the effects
of genetic susceptibility and indoor air pollution on childhood asthma in this population.
Forty-five participants (ages 11 to 20) entered the study between March and June of
2014, with enrollment limited to one subject per household. This study included 16
asthmatic children from residences within 75 m of the highway (“near-highway”
exposure group), 16 asthmatic children from residences that were over 150 m from the
road (“background” exposure group), and 13 non-asthmatic adolescent controls from
throughout the study area. These buffers from the highway were chosen in accordance
with the previous PM sampling conducted in the community and similar buffers that have
been employed by studies that include McConnell et al. (2006), Venn et al. (2001), and
van Vliet et al. (1997).
The general exclusion criteria for participants in this study included: current
pregnancy, bacterial or viral infection in the past week, and diagnosis of a chronic
respiratory disease, other than asthma (i.e. – tuberculosis, cystic fibrosis). Participants
were defined as moderate-to-severe persistent asthmatics if they reported at least one of
the following, in the four weeks prior to administration of the study questionnaire: 1)
daily asthma symptoms, 2) nighttime awakenings once a week or more, 3) daily use of
salbutamol (or any short-acting beta agonist), 4) some limitation with normal activity,
and 5) FEV1/FVC 75-79% (ages 9 – 11) or FEV1/FVC measure of 80-84% (ages 12 or
older). Spirometry was performed as previously described by Robinson et al. (2011).
Participant screening for atopy was completed with an Immunocap® Phadiatop in
vitro assay and three different allergen panels (animal epidermal and proteins, house dust,
!
! 87
and a mold and yeast mix) (IummunoCAP 250, ThermoFisher Scientific Inc., Rockville,
MD, USA). Serum IgE levels greater than 0.1 kUa/L were interpreted as positive IgE
antibody response. Participants with positive results for any of the allergen mixes were
considered to be atopic.
4.3.3. PM Sampling
The respirable fraction of airborne PM (50% cut-size of 4 µm) was sampled from
the rooftops of participant houses to assess ambient concentrations of particle mass, black
carbon, and bacterial endotoxin. PM samples were collected continuously over five-day
periods, spanning from Monday to Friday each week, between March and June of 2014.
On average, five homes were simultaneously sampled each week and samples were
collected from a total of 32 residences.
PM was sampled onto non-pyrogenic 37 mm polytetrafluoroethylene (PTFE)
filters (Catalog #66159, Pall Corporation, Port Washington, NY, USA) using BGI
Triplex cyclones (BGI, Waltham, MA, USA) and SKC XR5000 sampling pumps (SKC
Inc., Eighty Four, PA, USA). Samplers were calibrated to operate at a flow rate of 2.5
liters per minute and sampler flow rates were measured at the beginning and end of the
sampling period. Duplicate respirable PM cyclones were set up at each home to operate
side-by-side (one pre-weighed sample for gravimetric and BC analysis, and a second for
endotoxin and WBA testing). Field blanks and duplicates of these samples were collected
at 20% of the homes sampled. Eleven participant homes were sampled concurrently with
PEM PM2.5 impactors (Catalog #761-203A, SKC Inc) in order to assess for differences in
PM mass, BC, and endotoxin content of the respirable and PM2.5 particle size fractions.
!
! 88
All filter samples collected for gravimetric analysis were returned to JHU labs,
where they were conditioned for 24 hours in a temperature and humidity controlled room
and post-weighed on a Mettler Toledo XP2U microbalance (Mettler Toledo, Columbus,
OH, USA). Following gravimetric analysis, these filters were analyzed for BC content
based on a method previously described by Hansen et al. (1984).
4.3.4. Air Filter Extraction
Respirable PM and stimuli were extracted from PTFE filter membranes in a
Pampas field lab on the same day that sampling units were returned from households.
These filters were removed from samplers under a bench-top hood and aseptically
transferred into 12 ml non-pyrogenic glass vials (Catalog #03-391-7D, ThermoFisher
Scientific Inc.), using clean, gloved hands and forceps. Ten milliliters of pyrogen-free
water (PFW) (Catalog #25-055, Mediatech Inc., Manassas, VA, USA), containing 0.05%
Tween20 by volume (Catalog #BP337-500, Thermo Fisher Scientific Inc.) was then
pipetted into each vial to fully submerge filters in liquid. These vials were capped,
vigorously mixed for one minute, and then sonicated in a room temperature water bath
(Model # 97043-964, VWR International, West Chester, PA, USA) for 60 minutes to
dislodge particles and stimuli from the filter membrane. The resulting PM extract was
used as stimuli for whole blood incubations. The remaining sample eluate was pipetted
into sterile cryovials (Catalog #10-500-27, Thermo Fisher Scientific), which were frozen
at -20°C and transported back to JHU labs for endotoxin analysis.
4.3.5. Endotoxin Analysis
The endotoxin content of air filter extracts was quantified since bacterial
endotoxins are common contaminants in environmental PM that are known to induce
!
! 89
airway inflammation and are considered risk factors for asthma (Matsui et al., 2013;
Doreswamy & Peden, 2011). Endotoxin testing was completed with a kinetic
chromogenic Limulus Amebocyte Lysate (LAL) test (Pyrochrome® Lot #2041204,
Associates of Cape Cod Inc, E. Fallmouth, MA, USA), per the manufacturer’s
instructions. Briefly, LAL lysate was reconstituted with a manufacture-supplied buffer
(Glucashield® Lot #1207034, Associates of Cape Cod Inc.) to block potential false-
positive interference from β-glucans in the sample matrix. PM extracts were thawed at
room temperature and centrifuged at 1,000x g for 15 minutes to pellet insoluble particles.
Dilutions of the extract supernatant were then tested via LAL in duplicate. Each assay
included a five-point series dilution of the control standard endotoxin from Escherichia
coli O113:H10 (concentrations of 50, 5, 0.5, 0.05, and 0.005 Endotoxin Units (EU)/ml)
(Lot #249021, Associates of Cape Cod Inc.). Media blanks, field blanks, and spiked
samples (0.5 EU/ml), were included in the analysis for quality control. The LOD for the
test was 0.015 EU/ml and samples with endotoxin content below the LOD were assigned
a value of ½ the LOD (Adams, 1997).
4.3.6. Blood Collection
Peripheral whole blood was collected from consenting participants on Sundays,
between the hours of six and 10 am. Each participant donated blood only once for this
study and a regular time and schedule was maintained for all blood draws, since circadian
rhythms affect whole blood cytokine release (Hermann et al., 2006). A certified
phlebotomist collected 4 ml of blood into sterile blood collection tubes, which contained
75 USP units of sodium heparin (Catalog #367871, Becton Dickinson, Franklin Lakes,
NJ, USA). This batch of blood collection tubes was pre-tested to ensure that it was free of
!
! 90
pyrogenic contamination, which could pre-activate the whole blood system (data not
shown here). Heparinized whole blood was added to incubation vials within 1 hour of the
blood draw, and blood was kept at room temperature and out of direct light until it was
incubated.
EDTA-treated whole blood was also collected from participants for complete
blood cell (CBC) counts and a white blood cell (WBC) differential. All CBCs were
performed by a local third-party laboratory (Medlab, Lima, Peru). One milliliter of
EDTA-treated whole blood from each participant was processed using a Sysmex XE-
2100 (Sysmex America, Inc., Mundelein, IL). An average of 32,000 cells were counted
for the determination of the WBC differential.
4.3.7. Whole Blood Incubation
Peripheral whole blood from all donors was challenged with two concentrations
of E. coli endotoxin (10 µg/ml and 100 ng/ml) (Lot #249020, Associates of Cape Cod
Inc.), PFW (negative control), and a reference solution of PM2.5 particles. This PM2.5
extract was derived from ambient air samples in the Pampas community, prior to the start
of the study. The extract contained a mass concentration of 60 µg/ml (BC/PM = 12%)
and an endotoxin content of 0.5 EU/ml. Asthmatic participants had aliquots of their blood
incubated with extracts of ambient respirable PM, which were unique to each
participant’s house location. Triplicate incubations of PM2.5 and respirable PM were
included for 10% of study participants.
Sterile 2 ml cryovials (vendor) were prepared with 1.2 ml of sterile RPMI 1640 +
L-Glutamine/HEPES, 300 µl of stimuli (i.e. – endotoxin, PM extract, PFW), and 300 µl
of heparinized whole blood. These vials were gently mixed and placed in a thermoblock
!
! 91
incubator, set to operate at 37°C. After 24 hours, the vials of blood were removed from
the incubator, mixed, and then aliquoted to 1.5 ml microcentrifuge tubes. Incubated blood
was immediately frozen at -20°C and transferred to a lab at the University of Cayetano
(Lima, Peru) for storage at -70°C.
4.3.8. Cytokine Analysis
Concentrations of IL-1β were measured in the cell-free supernatant of whole
blood incubations for each study participant. Blood was thawed at room temperature,
mixed briefly, and then centrifuged at 10,000x g for two minutes. The resulting
supernatant was withdrawn and tested in technical triplicate in a sandwich enzyme linked
immunosorbent assay (ELISA), using commercial ELISA kits (Duoset Kit DY201, R&D
Systems, Minneapolis, MN). ELISA analysis was completed per the protocol described
by Daneshian et al. (2009), and the sensitivity of the ELISA was 3.9 pg/ml. Participant
cytokine responses were expressed as nanograms (ng) of IL-1β produced per million
exposed monocytes (ng/106 monocytes). IL-1β responses from the WBA analysis were
normalized by participant monocyte counts since this cell population serves as the
primary source of IL-1β in the whole blood system and may vary between individuals
(Boneberg & Hartung, 2002).
4.3.9. Statistical Analysis
Statistical analysis was completed in GraphPad Prism 6.0e (Prsim, La Jolla, CA,
USA), and exploratory data analysis was conducted to determine summary statistics for
each group of study covariates. All data were evaluated for normality use a Shapiro-Wilk
test, and lognormal data were transformed prior to evaluation with parametric tests. Un-
paired, two-tailed Student’s t-tests, or non-parametric Mann-Whitney U Tests, were used
!
! 92
to assess between-group differences (e.g. – asthmatics vs. non-asthmatics), with regards
to subject characteristics, environmental measures, and WBA responses. Pearson
correlation coefficients were calculated for log-transformed data to assess relationships
between WBA cytokine response and the respective mass, endotoxin, and BC
concentrations of the respirable PM extracts. One-way ANOVAs (with Dunnett’s post
test) were used to evaluate the equivalency of mean values between three or more groups,
with multiple comparisons to a reference group (non-asthmatics). The p-value threshold
for statistical significance was set at 0.05.
!
! 93
4.4. Results
4.4.1. Environmental Concentrations of PM, Black Carbon, & Endotoxin
The respirable fraction of ambient PM was sampled from rooftops of participant
homes in Pampas. Between March and June of 2014, ambient concentrations of PM and
BC were found to be consistently higher at homes near the highway (distance < 75 m), as
compared to background distances (distance > 150 m). The bacterial endotoxin content of
ambient respirable PM was low and did not differ by proximity to the highway.
Table 4.1. Ambient Respirable PM, Black Carbon, and Endotoxin
Near-Highway1
(N = 16)
GM (95% CI)
Background1
(N = 16)
GM (95% CI)
Respirable PM
µg/m3
27.2 (24.2 – 30.6)*
23.6 (21.0 – 26.6)
Black Carbon
µg/m3
BC/PM (%)
8.4 (7.4 – 9.6)***
31% (27% – 34%)***
5.8 (5.1 – 6.6)
23% (21% - 25%)
Endotoxin3
EU/m3
EU/mg
EU/ml (extract)
0.07 (0.04 – 0.13)
2.7 (1.4 – 5.2)
0.13 (0.08 – 0.21)
0.08 (0.05 – 0.15)
3.4 (1.8 – 6.3)
0.19 (0.13 – 0.29)
1 Near-Highway: residence < 75 m from highway; Background group: residence >150 m from highway
2 Statistical significance: * p<0.05, ** p<0.01, *** p<0.001; Un-paired, two-tailed Student’s t test
3 Endotoxin sample sizes: Near-Highway group (N = 15); Background group (N = 13). Endotoxin data
were missing for samples from four participant homes.
!
! 94
The respirable and PM2.5 particle size fractions were simultaneously sampled at
11 homes in the study area. Figure 4.2 summarizes the relationship between the average
concentrations of this PM in ambient air near the highway and at background distances.
Between sampling zones (near-highway vs. background), only the respirable fraction of
PM and BC differed by proximity to the highway. A paired, two-way Student’s t-test was
used to assess differences between particle sizes fractions within sampling zones No
differences in PM mass concentrations or BC content were found, suggesting that the
preponderance of respirable particles in the air were in the PM2.5 size fraction. However,
ambient concentrations of respirable PM and BC remained higher at sampling sites near
the highway, as was reported for the analysis of full set of respirable PM samples.
Figure 4.2. Respirable and PM2.5 fractions of ambient PM and BC in the study area.
!
! 95
4.4.2. Study Population Characteristics
Descriptive statistics for study participants are presented in Table 4.2. Asthmatic
subjects in this study were predominantly male, while the majority of controls were
female. A high prevalence of atopy was reported across all participants, regardless of
asthma status. No difference in pre-bronchodilator FEV1 and FVC, or predicted-FEV1,
was measured between asthmatic and non-asthmatics groups. On average, asthmatics
were found to have an 8% lower baseline FEV1/FVC (un-paired Student’s t test, p <0.05).
Table 4.2. Summary of Participant Characteristics
Asthmatics
(N = 32)
Controls
(N = 13)
Age, years [median (range)] 15 (11 - 20) 14 (11 - 17)
Sex, % female 22% 69% -
Atopy, % 1 70% 80%
BMI, kg/m2 [median (range)] 22.2 (16.5 – 33.0) 23.5 (17.7 – 30.7)
FVC, L [median (range)] 3.7 (2.2 – 6.4) 3.5 (2.1 – 6.0)
FEV1, L [median (range)] 3.2 (1.7 – 4.9) 3.2 (1.9 – 5.1)
FEV1, %-predicted [median (range)] 101.5 (94.2 – 107.3) 115.0 (98.6 – 122.0)
FEV1/FVC, % [median (range)] 82.3 (80.0 – 86.3) 89.1 (82.2 – 98.2)*
1 Two asthmatics and 3 controls were excluded from calculation of prevalence for lack of atopy data
2 Statistical significance: * = p<0.05; Un-paired, two-tailed Student’s t test
3 Measures indicate pre-bronchodilator responses
4.4.3. Differential Blood Cell Counts
In the whole blood system, monocytes serve as the primary source of acute phase
cytokines such as IL-1β and IL-6 (Boneberg & Hartung, 2002). Other leukocyte sub-
populations, such as eosinophils, are capable of secreting such mediators, but do so at
!
! 96
significantly lower levels (Spencer et al., 2014). A complete blood cell count with a
differential count of leukocytes was determined for each subject’s blood donation to
control for variations in cell counts that would influence the WBA response. The
summary statistics of the differential white blood cell (WBC) counts are summarized in
Table 4.3. The asthmatic subjects were further dichotomized based on the proximity of
their residence to the highway, since subjects living within 75 m of the highway exhibited
higher relative blood monocyte counts than asthmatics in the background exposure group
or non-asthmatics in the control group. No other significant differences in WBC counts
were observed between sexes or within groups. Notably, the eosinophil counts for
controls were also high (3.9% of WBC) and 80% of these children were atopic.
Table 4.3. Differential White Blood Cell Counts
Asthmatics1, Non-asthmatic
Controls
GM (95% CI)
(N =13)
Near-Highway
GM (95% CI)
(N = 16)
Background
GM (95% CI)
(N = 16)
p-
value3
WBC (103 cells/µl)2,3 7.4 (6.3 – 8.6) 6.8 (5.9 – 7.7) 6.9 (6.0 – 8.0) 0.5
Lymphocytes (% WBC) 37.3 (33.9 – 41.0) 35.8 (30.7 – 41.7) 35.4 (30.9 – 40.4) 0.9
Neutrophils (% WBC) 47.0 (42.5 – 52.1) 47.6 (42.5 – 53.3) 48.3 (39.9 – 58.3) 0.8
Monocytes (% WBC) 6.4 (5.7 – 7.3)* 5.1 (4.6 – 5.7) 5.8 (4.8 – 6.9) 0.03
Eosinophils (% WBC) 6.5 (4.8 – 8.7) 4.1 (2.5 – 6.7) 3.9 (2.7 –5.5) 0.1
Basophils (% WBC) 0.2 (0.0 – 0.4) 0.2 (0.0 – 0.3) 0.1 (0.0 - 0.2) 0.6
1 Asthmatic participants grouped by location of the residence, in relation to highway. Near-Highway
group: residence < 75 m from highway; Background group: residence >150 m from highway.
2 Absolute WBC counts, with sub-populations reported as relative percentage of total WBC (% WBC).
3 One-way ANOVA with Dunnett’s post test: *p<0.05, with non-asthmatics as reference group.
!
! 97
4.4.4. WBA Cytokine Response
To determine if IL-1β response of whole blood differed by asthma status, donor
blood was stimulated, ex vivo, with endotoxin at two concentrations (10 µg/ml and 100
ng/ml), and a single extract of PM2.5 particles collected from air near the roadside in
Pampas. Figure 4.3 summarizes IL-1β cytokine responses for the asthmatic and non-
asthmatic groups. No difference in mean cytokine response was evident between groups
following stimulation with either endotoxin or PM2.5. Similarly, no difference in IL-1β
response was observed when participants were dichotomized by sex or atopy status. The
IL-1β signal from the WBA testing was normalized to donor monocyte counts. The
coefficient of variation for triplicate WBA incubations of PM2.5 samples was 10%,
indicating strong reproducibility of whole blood responses to this complex stimulus.
Figure 4.3. No difference between asthmatic and non-asthmatic participants in
WBA IL-1β response to endotoxin (Panels A & B) or PM2.5 (Panel C)..
!
! 98
We next evaluated the WBA data as a function of residential proximity to the
four-lane highway that splits the Pampas study area. Since asthma status had no apparent
influence on IL-1β responses to endotoxin or PM2.5, study participants were grouped by
the proximity of the residence to the study area highway. Figure 4.4 summarizes the IL-
1β responses for the children living within 75 m of the road, and those living 150 m or
more from the road.
!Figure 4.4. IL-1β responses to WBA stimulation with PM 2.5 are reduced for study
participants living within 75 meters of the study area highway in Pampas
These results indicated that the pro-inflammatory potential of traffic PM2.5 was
attenuated for all subjects from residences within 75 m of the highway. In comparison to
subjects who lived farther from the road (< 150 m), the peripheral blood from participants
living within 75 m of the road released 50 percent less IL-1β (normalize to monocyte
count) in response to stimulation with an extract of ambient PM2.5 particles collected
!
! 99
from the study area. This disparity in IL-1β response was not observed when participant
blood stimulated with purified endotoxin. Sensitivity analysis, in which outlier cytokine
responses were excluded (based on Grubb’s test), did not significantly alter statistical
relationships.
! !
Table 4.4. Correlation analysis, comparing WBA cytokine response with
concentrations of PM mass, BC, and endotoxin in ambient respirable PM extracts
N
Pearson Correlation
Coefficient 1,2
p-value
Respirable PM Mass vs. IL-1β.Response
Near-highway 15 0.56 0.03
Background 15 0.34 0.11
Black Carbon vs. IL-1β.Response
Near-highway 15 0.34 0.22
Background 15 0.24 0.38
Endotoxin vs. IL-1β.Response
Near-highway 14 0.46 0.08
Background 12 0.78 <0.01
1 Samples grouped by sampling location in relation to highway. Near-Highway group: residence < 75 m
from highway; Background group: residence >150 m from highway.
!
! 100
Given the potential for spatial variation in the composition of the respirable PM
collected for this study, we sought to investigate correlations between IL-1β cytokine
response and the PM mass, BC, and endotoxin content of the sample extracts used to
stimulate participant whole blood (summarized in Table 4.4). Here, we observed a
modest positive correlation (r = 0.78, p <0.01) between log-transformed participant IL-1β
responses and the log-endotoxin content of respirable PM samples that were collected
from background locations (distances >150 m). However, endotoxin and IL-1β were not
correlated for participants living within 75 m of the highway (r = 0.45, p = 0.08). The
particle mass concentration of the respirable PM extract and IL-1β responses were
weakly associated for these individuals living near the highway (r = 0.56, p <0.05), with
association observed at background. No other significant correlations between PM
samples and WBA responses were found and the exclusion of statistical outliers did not
significantly alter relationships.
!
!
!
!
! 101
4.5. Discussion
Residential proximity to major highways is strongly associated with increased
exposure to ambient traffic pollution in many populations (HEI, 2010). In the context of
childhood asthma, the increased traffic PM exposures that occur near to highways have
been associated with an elevated prevalence of asthma symptoms (McConnell et al.,
2006; Venn et al., 2001), decreased lung function (Holguin et al., 2007), and high rates of
allergic sensitization (Baumann et al., 2011; Morgenstern et al., 2008). However,
aeroallergens do not appear to consistently explain the hazards of this PM for asthmatics
(Miller & Peden, 2014). Despite the increasing mass of evidence to substantiate traffic
PM exposure as a risk factor for asthma, it remains difficult to determine if asthmatics are
uniquely susceptible to traffic PM-induced inflammation.
This study investigated the capacity of two distinct types of stimuli (E. coli
endotoxin and traffic PM) to elicit the release of a conserved pro-inflammatory cytokine
from the peripheral whole blood systems of non-asthmatic and persistent asthmatic
children who live near to and far from a major highway. To our knowledge, this is the
first study to employ this WBA approach for the purposes of air quality exposure
assessment in asthmatic populations. The children who were enrolled in this study were
recruited from homes clustered around a busy four-lane highway in the Pampas
community. Half of these children lived within 75 m of the highway, while the remainder
lived at background distances of 150 m or more. Study participants were recruited from
these zones after preliminary sampling indicated that the BC content of ambient PM2.5
decreased at distances beyond 100 m from this highway. Therefore, significant reductions
!
! 102
in traffic PM constituents were considered to occur at distances of 100 m or more from
the highway.
The PM sampling that was conducted for this project focused on the respirable
fraction of ambient particles, as opposed to the PM2.5 fraction, since these samples were
collected for use in the WBA. The respirable fraction, a deposition-based sampling
convention, was considered to represent a more biologically representative fraction of
particles and stimuli from the environment, which may be excluded by PM2.5 sampling
(Cherrie & Aitken, 1999). The air sampling for this study indicated that respirable
concentrations of PM near the main highway were only 1.2 times greater than at
background (27.2 µg/m3 vs. 23.6 µg/m3, p = 0.04). Co-located PM2.5 samples collected
from these locations showed no significant differences, with the respirable size fraction
indicating that most of the particle mass was less than 2.5 µm in diameter. On average,
both the ambient respirable PM and PM2.5 concentrations in this study area exceeded the
World Health Organization’s (WHO) guideline for annual average concentrations of
PM2.5 (10 µg/m3) and were nearly equivalent with the World Health Organization’s
guideline for maximum average 24-hour exposures to PM2.5 (25 µg/m3) (WHO, 2005).
The BC content of this PM was investigated as a traffic-related exposure variable
and as a proxy for the potential of this PM to stimulate IL-1β cytokine response from the
WBA. BC is often treated as an indicator of traffic pollutants (e.g. – metals, polyaromatic
hydrocarbons) (Janssen et al., 2011). The estimated mass concentration of BC in ambient
air near the highway was 1.5 times that of background levels (8.4 µg/m3 vs. 5.8 µg/m3, p
<0.001). The average highway-to-background ratio of PM and BC observed in this study
was in fair agreement with results of the systematic review conducted by Janssen et al.,
!
! 103
(2011). Moreover, the spatial relationship in BC content reflects the concentration
gradients reported by Zhu et al. (2002) and Hitchins et al. (2000), who conducted studies
of ultrafine PM in the vicinity of heavily trafficked roadways and freeways.
Bacterial endotoxins were a second class of constituents that were quantified in
the PM samples for this study. Endotoxins are lipopolysaccharides from Gram-negative
bacteria, which carry potent immunostimulatory potential in the human innate immune
system (Beutler & Rietschel, 2003), and are also considered a risk factor for asthma
(Doreswamy & Peden, 2011; Breysse et al., 2010). The endotoxin content of PM was
measured in this study to control for its pro-inflammatory effects in the WBA. We also
assessed the concentrations of respirable endotoxin in the ambient air of Pampas.
The endotoxin content of this respirable PM did not differ spatially across the
study site. At an average content of 3.3 EU/mg, Pampas PM carried a relatively low
burden in comparison to that of urban Baltimore City air (measured at 19 EU/mg in
unpublished data from the lab of this study’s investigators). In filter eluates, the average
endotoxin concentration of respirable PM samples was 0.1 EU/ml. This concentration is
generally considered to be below the whole blood system’s threshold of sensitivity for
endotoxin, which is reported in the range of 0.25 – 0.5 EU/ml (Hasiwa et al., 2013;
Daneshian et al., 2009). However, 31 of the 32 respirable PM samples generated a
significant IL-1β response in the WBA, suggesting that a non-endotoxin source of stimuli
contributed to the pro-inflammatory potential of this PM.
For PM samples collected from ambient air at background distances, respirable
endotoxin (but not PM mass) was modestly correlated with the WBA cytokine response
(r = 0.78, p < 0.01). This testing used whole blood from participants living in the homes
!
! 104
where these samples were collected. The correlation between respirable endotoxin and
the IL-1β signal of the WBA was not found when PM samples collected near the
highway were tested (r = 0.46, p = 0.08). However, the IL-1β signal generated by WBA
tests of near-highway PM was weakly correlated with PM mass (r = 0.56, p = 0.03).
Overall, the WBA analysis for this study suggested that residential proximity to
the highway, but not asthma status, was most strongly associated with altered acute phase
cytokine response in peripheral whole blood from these study participants. When the IL-
1β signal from PM2.5-stimulated whole blood was normalized to the participant’s blood
monocyte count, it was found that IL-1β responses from subjects living near the highway
were approximately one-half that of children who lived at background distances. This
difference was not evident in un-adjusted IL-1β responses due to the elevated blood
monocyte counts of asthmatic children who lived near the highway. No difference in
mean blood monocyte counts were observed for controls in this study, although they
represent a small sample size to draw conclusions from.
Although we are aware of no previous studies that have used WBA methods to
investigate environmental PM exposure in asthmatic or atopic whole blood, there are a
variety of WBA studies that have assessed acute phase inflammatory responses to
challenge with endotoxins, fungal material, and settled dust. Bettiol and colleagues
(2000) used WBA methods to assess innate and adaptive cytokine responses (TNFα, IL-
6, IFNγ, and IL-4) to endotoxin and phytohaemagglutinen (PHA) exposure, using fresh
whole blood from asthmatic (atopic and non-atopic) and non-asthmatic adults (healthy
controls). The authors of this study reported that whole blood from both atopic and non-
atopic asthmatics displayed higher background levels of IL-6 in un-stimulated blood, as
!
! 105
compared to non-atopic, non-asthmatic controls. Both atopic and non-atopic asthmatics
were also shown to have an enhanced release of IL-6 following stimulation with
endotoxin, in comparison to healthy controls. No difference in the IL-6 signal was
evident between atopic and non-atopic asthmatics. Conversely, when the TNFα signal
was measured in the same incubations, no differences in response to endotoxin were
found between groups of participants, regardless of asthma or atopy status.
Although Bettiol and colleagues did not measure IL-1β in this study, TNFα and
IL-6 also represent acute phase inflammatory cytokines that are similarly implicated in
the innate immune response and carry overlapping inflammatory properties with IL-1β.
The disparate trends in endotoxin-induced TNFα and IL-6 measures in this study suggest
that multiple acute phase cytokines may need to be assessed to properly detect
differences in individual responses to stimuli such as endotoxin. Just as endotoxin may
not explain the total pro-inflammatory potential of PM, a single non-specific
inflammatory cytokine may not sufficiently explain the inflammatory response to
stimulation with complex environmental samples.
Sahlander et al. (2010) assessed innate immune function via WBA in individuals
with chronic exposure to endotoxin and organic agricultural dusts. WBA cytokine
responses (IL-6) were quantified for swine farmers and healthy controls, following ex
vivo stimulation of whole blood with endotoxin and settled dust from a swine barn. In
comparison to healthy controls, swine farmers displayed a dampened IL-6 signal in the
WBA following stimulation with swine facility dust, but not endotoxin. Cytokine
concentrations were normalized to total leukocyte counts.
!
! 106
Based on the endotoxin analysis of this study’s respirable PM samples, children in
the Pampas community were not chronically exposed to high levels of ambient endotoxin
or other biogenic constituents. However, participants living near the busy four-lane
highway were exposed to slightly higher concentrations of ambient traffic PM and
significantly higher concentrations of BC. These were also children who exhibited
comparatively lower IL-1β responses following WBA stimulation with PM2.5 collected
from roadside air in the study area. Yet, no difference was observed for endotoxin-
induced IL-1β signals for any group of study participants. It is possible that high levels of
atopy in this study population played a role in mediating the IL-1β response to endotoxin
and potentially reduced the heterogeneity in responses. The endotoxin concentrations
used were also significantly higher than the measured endotoxin content of the PM
extract. These differences in response may only be apparent at low levels of stimulation.
There are a number of study limitations that may have affected the outcomes of
this study. The sample size for this study was modest, which reduced the statistical power
to detect differences in IL-1β signal between groups of individuals. Participants were also
predominantly atopic, and the effects of atopy on WBA cytokine response are not well
established. Additionally, only a single inflammatory cytokine was tested in these
incubations. As shown by Bettiol and colleagues (2000), other inflammatory cytokines
may respond differently to the stimuli, particularly for complex mixtures like traffic PM.
Testing these whole blood incubations for a broad panel of cytokines would serve
to better characterize immune responses and provide insight into both innate and adaptive
responses. Collecting air samples and participant blood at multiple time points would also
enhance our understanding for the immunologic effects of traffic PM exposures in these
!
! 107
individuals. Wouters et al. (2002) and Spreitzer et al. (2007) have shown that greater
variations in cytokine production occur between individuals (rather than within
individuals). However, the findings of this study would be more robust if repeat measures
were obtained, since the composition of PM may change over time as well.
Lastly, this study focused on the pro-inflammatory effects of respirable PM and
PM2.5. Other relevant pro-inflammatory stimuli may be carried by larger non-respirable
PM, which could also serve to stimulate bronchial inflammation and exacerbate asthma.
Notably, the highest endotoxin signals have often been associated with the larger
diameter of aerosolized particles. The thoracic fraction of PM, which still deposits in the
conducting airways, may carry a different pro-inflammatory hazard for these children.
The concentrations of this PM, in relation to the highway, may also differ significantly
since the larger particles (re-suspended by traffic activity) settle faster than those of the
respirable diameter.
!
! 108
4.6. Conclusions
In conclusion, the findings of this study provide exploratory evidence of altered
systemic innate immune function in asthmatic and non-asthmatic children living near this
four-lane highway in the Pampas community. Study participants who lived within 75 m
of the highway where exposed to ambient concentrations of traffic PM and BC that were
elevated above background levels measured at distance of 150 m or more from the
highway. The WBA analysis did not reveal obvious signs of an immunologic
susceptibility to traffic PM or endotoxin for asthmatic children. The results of this study
contribute to the existing evidence-base that suggests that close residential proximity to
major highways is a risk factor in the immunologic health of individuals with chronic
exposure to traffic pollution.
Acknowledgements ! This research was supported by project 3R01ES018845-04S1 (Genetic
Susceptibility to Asthma and Indoor Air Pollution in Peru) from the National Institute of
Health (PI: Nadia Hansel).
!!!!!!!!!!!!!
!
! 109
!!!!!!!!!!!!!
Chapter 5
!
!!!!!!!!!!!!!!!!!!!!!!
!
! 110
5.1 Summary
The research presented in this dissertation focuses on the use of human WBA
methods to assess the capacity of environmental PM to stimulate inflammation. Taken
together, the results of the two field studies demonstrate the flexibility of the human
WBA to provide insight into both the pro-inflammatory characteristics of complex
environmental stimuli and individual immune responses to a variety of different stimuli.
The integrative capacity of the WBA is an attractive element for exposure assessment
purposes as it is capable of assessing exposures in a manner that is similar to exposures in
nature. The assay is capable of assessing mixtures and it also mimics the acute phase
cytokine response that results from the interplay between environmental stimuli and the
human innate immunity.
5.1.1. Broiler Poultry House PM
The study of the broiler poultry house environment, presented an opportunity to
use the WBA as a standardized method for contrasting the pro-inflammatory potential of
different environmental samples. While WBA methods have traditionally been
confounded by differences in donor whole blood systems, the use of pooled,
cryopreserved whole blood allowed for a variety of PM samples to be collected at
different time points and tested within a standardized whole blood system.
The cryopreserved WBA provided evidence that the quantification of endotoxin,
alone, does not capture the total pro-inflammatory potential of PM from the broiler
poultry house environment. This was not surprising, given the diverse microbial
communities in the poultry houses. The WBA testing indicated that as much as half of the
pro-inflammatory signal is mediated by non-endotoxin stimuli in the PM matrix. This
!
! 111
WBA analysis also allowed for the investigation of insoluble stimuli, which are discarded
in the LAL testing process, and indicated that they account for as much 50 percent of the
total IL-1β response observed in the analysis. Further research needs to be conducted to
determine the composition of stimuli in both the “non-endotoxin” and “insoluble”
fractions of this PM, such that we can better understand which biogenic sources of PM
are the most important in these environments.
There is also a need to incorporate WBA methods into human exposure studies to
better evaluate the exposure-response relationships between PM inhalation and the
variety of non-infectious respiratory health effects that are thought to be driven by
biogenic constituents. This is important since the LAL-measured endotoxin content of
organic dusts and PM may not reliably predict the occurrence or severity of these health
effects. Therefore, it is critical to holistically determine the pro-inflammatory potential of
PM and identify which size fractions carry the most hazardous burden of stimuli. In the
this study, when the LAL and WBA signals were normalized to PM mass, the larger
particle fractions consistently carried the greatest burden of endotoxin and the highest
capacity to elicit the release of IL-1β from cryopreserved whole blood. However, the
threshold for eliciting airway inflammation in different zones of the respiratory tract are
not well understood and thus it may require only a low burden of stimuli in the small
particle sizes to represent a hazard for the sensitive small airways.
Overall, the cryopreserved WBA shows promise as an exposure assessment tool.
In the future the WBA method needs to be optimized to determine how to most
efficiently test PM samples (e.g. – concentrations of extracts, whole filters, bulk PM) and
how to best capture the relevant cytokine responses. Currently the air filter extraction
!
! 112
process contains many critical points at which stimuli may either be lost or introduced in
the sample. For WBA methods to gain added traction in exposure science, they will need
to be further standardized, such that results are more easily interpreted and carry
enhanced generalizability.
5.1.2. Traffic PM & Asthma
! The use of WBA methods in the study presented a very different challenge from
that of the poultry house study. While the results of the WBA analysis did not yield
significant insight into immunologic susceptibilities of asthmatic children who were
exposed to traffic PM, they did provide evidence that a conserved element of systemic
immune function differs between children living near and far from the major highway in
the study site. This finding warrants further investigation as it suggests that innate
immune response to constituents in traffic-related PM is attenuated for individuals with
chronic exposure. Since acute phase inflammation is critical component of both front line
of defenses against infection and the repair of tissue injury, a depressed response to
innate immune stimulation may confer a susceptibility to immunologic challenges from
the environment that are accompanied by traffic-related PM constituents. However, we
are careful to also note that peripheral whole blood from all study subjects responded
similarly to challenge with purified endotoxin. Thus, innate response to bacterial PAMPs
does not appear to be similarly affected.
To add to this research, a larger panel of cytokines needs to be assessed in whole
blood incubations from these children, such that the innate and adaptive immune
responses can be better characterized and contrasted between individuals. While IL-1β
has proven to be a suitable marker of inflammatory response to stimulation in a variety of
!
! 113
endotoxin and non-endotoxin stimuli, it is unlikely to summarize the full acute phase
response to environmental PM exposures. WBA incubations provide the opportunity to
extract a wealth of immunologic data. A concerted effort should be made to extract more
comprehensive biologic insight and incorporate high throughput approaches towards
assessing these PM exposures.
The WBA also serves as a field applicable immunologic assay that allowed our
study team to conduct a significant amount of this work in a low-resource field in the
study area. This simplified the logistics of the study, allowed for the use of commercially
available reagents and equipment, and did not require extensive handling or processing of
blood for the test. The results of the study provided us with a snapshot of the innate
immune function of these asthmatic and non-asthmatic Peruvian children that could not
have been achieved with another assay under these conditions.
!!!!!!!!!!!!!!!!!!!!!
!
! 114
References
ACGIH. (2012) 2012 Threshold limit values and biological exposure indices. Cincinnati,
OH: ACGIH.
Adams, N. H. (n.d.). The use of method detection limits in environmental measurements.
Quality Assurance (San Diego, Calif.), 5(4), 257–64.
Akira, S., Uematsu, S., & Takeuchi, O. (2006). Pathogen recognition and innate
immunity. Cell, 124(4), 783–801.
Alexis, N. E., & Carlsten, C. (2014). Interplay of air pollution and asthma
immunopathogenesis: A focused review of diesel exhaust and ozone. International
Immunopharmacology.
Andersen, C. I., Von Essen, S. G., Smith, L. M., Spencer, J., Jolie, R., & Donham, K. J.
(2004). Respiratory symptoms and airway obstruction in swine veterinarians: a
persistent problem. American Journal of Industrial Medicine, 46(4), 386–92.
Anderson, J. O., Thundiyil, J. G., & Stolbach, A. (2012). Clearing the air: a review of the
effects of particulate matter air pollution on human health. Journal of Medical
Toxicology!: Official Journal of the American College of Medical Toxicology, 8(2),
166–75.
Arfken, A. M., Song, B., & Sung, J. S. (2014). Comparison of Airborne Bacterial
Communities from Hog Farm and Spray Field. Journal of Microbiology and
Biotechnology.
!
! 115
Basinas, I., Sigsgaard, T., Heederik, D., Takai, H., Omland, Ø., Andersen, N. T., …
Schlünssen, V. (2012). Exposure to inhalable dust and endotoxin among Danish
livestock farmers: results from the SUS cohort study. Journal of Environmental
Monitoring!: JEM, 14(2), 604–14.
Basinas, I., Sigsgaard, T., Kromhout, H., Heederik, D., Wouters, I. M., & Schlünssen, V.
(2013). A comprehensive review of levels and determinants of personal exposure to
dust and endotoxin in livestock farming. Journal of Exposure Science &
Environmental Epidemiology, (October 2012), 1–15.
Baumann, L. M., Robinson, C. L., Combe, J. M., Gomez, A., Romero, K., Gilman, R. H.,
… Checkley, W. (2011). Effects of distance from a heavily transited avenue on
asthma and atopy in a periurban shantytown in Lima, Peru. The Journal of Allergy
and Clinical Immunology, 127(4), 875–82.
Becker, S., Clapp, W. a, Quay, J., Frees, K. L., Koren, H. S., & Schwartz, D. a. (1999).
Compartmentalization of the inflammatory response to inhaled grain dust. American
Journal of Respiratory and Critical Care Medicine, 160(4), 1309–18.
Bernasconi, C., Rodolfi, M., Picco, A. M., Grisoli, P., Dacarro, C., & Rembges, D.
(2010). Pyrogenic activity of air to characterize bioaerosol exposure in public
buildings: a pilot study. Letters in Applied Microbiology, 50(6), 571–7.
Bettiol, J., Bartsch, P., Louis, R., De Groote, D., Gevaerts, Y., Louis, E., & Malaise, M.
(2000). Cytokine production from peripheral whole blood in atopic and nonatopic
!
! 116
asthmatics: relationship with blood and sputum eosinophilia and serum IgE levels.
Allergy, 55(12), 1134–41.
Beutler, B., & Rietschel, E. T. (2003). Innate immune sensing and its roots: the story of
endotoxin. Nat Rev Immunol, 3(2), 169–176.
Biswas, S., McGrath, J. M., & Sapkota, A. (2012). Quantification of ionophores in aged
poultry litter using liquid chromatography tandem mass spectrometry. Journal of
Environmental Science and Health. Part. B, Pesticides, Food Contaminants, and
Agricultural Wastes, 47(10), 959–66.
Blais Lecours, P., Veillette, M., Marsolais, D., & Duchaine, C. (2012). Characterization
of bioaerosols from dairy barns: reconstructing the puzzle of occupational
respiratory diseases by using molecular approaches. Applied and Environmental
Microbiology, 78(9), 3242–8.
Boneberg, E.-M., & Hartung, T. (2002). Granulocyte colony-stimulating factor attenuates
LPS-stimulated IL-1beta release via suppressed processing of proIL-1beta, whereas
TNF-alpha release is inhibited on the level of proTNF-alpha formation. European
Journal of Immunology, 32(6), 1717–25.
Brandenburg, K., Howe, J., Gutsman, T., & Garidel, P. (2009). The expression of
endotoxic activity in the Limulus test as compared to cytokine production in
immune cells. Current Medicinal Chemistry, 16(21), 2653–60.
!
! 117
Breysse, P. N., Diette, G. B., Matsui, E. C., Butz, A. M., Hansel, N. N., & McCormack,
M. C. (2010). Indoor air pollution and asthma in children. Proceedings of the
American Thoracic Society, 7(2), 102–6.
Brunekreef, B., & Holgate, S. T. (2002). Air pollution and health. Lancet, 360(9341),
1233–42.
Castellan, R. M., Olenchock, S. A., Kinsley, K. B., & Hankinson, J. L. (1987). Inhaled
endotoxin and decreased spirometric values. An exposure-response relation for
cotton dust. The New England Journal of Medicine, 317(10), 605–10.
Cavagna, G., Foà, V., & Vigliani, E. C. (1969). Effects in man and rabbits of inhalation
of cotton dust or extracts and purified endotoxins. British Journal of Industrial
Medicine, 26(4), 314–21.
Cavaillon, J. M., & Haeffner-Cavaillon, N. (1986). Polymyxin-B inhibition of LPS-
induced interleukin-1 secretion by human monocytes is dependent upon the LPS
origin. Molecular Immunology, 23(9), 965–9.
Cherrie, J. W., & Aitken, R. J. (1999). Measurement of human exposure to biologically
relevant fractions of inhaled aerosols. Occupational and Environmental Medicine,
56(11), 747–52.
Cherrie, J. W., Brosseau, L. M., Hay, A., & Donaldson, K. (2013). Low-toxicity dusts:
current exposure guidelines are not sufficiently protective. The Annals of
Occupational Hygiene, 57(6), 685–91.
!
! 118
Cox, K. H., Cox, M. E., Woo-Rasberry, V., & Hasty, D. L. (2012). Pathways involved in
the synergistic activation of macrophages by lipoteichoic acid and hemoglobin. PloS
One, 7(10), e47333.
Daneshian, M., von Aulock, S., & Hartung, T. (2009). Assessment of pyrogenic
contaminations with validated human whole-blood assay. Nature Protocols, 4(12),
1709–21.
Davidson, C. I., Phalen, R. F., & Solomon, P. A. (2005). Airborne Particulate Matter and
Human Health: A Review. Aerosol Science and Technology, 39(8), 737–749.
Dehus, O., Hartung, T., & Hermann, C. (2006). Endotoxin evaluation of eleven
lipopolysaccharides by whole blood assay does not always correlate with Limulus
amebocyte lysate assay. Journal of Endotoxin Research, 12(3), 171–80.
Deininger, S., Traub, S., Aichele, D., Rupp, T., Baris, T., Möller, H. M., … von Aulock,
S. (2008). Presentation of lipoteichoic acid potentiates its inflammatory activity.
Immunobiology, 213(6), 519–29.
DeKruyff, R. H., Yu, S., Kim, H. Y., & Umetsu, D. T. (2014). Innate immunity in the
lung regulates the development of asthma. Immunological Reviews, 260(1), 235–48.
Delfino, R. J., Staimer, N., Tjoa, T., Gillen, D., Kleinman, M. T., Sioutas, C., & Cooper,
D. (2008). Personal and ambient air pollution exposures and lung function
decrements in children with asthma. Environmental Health Perspectives, 116(4),
550–8.
!
! 119
Delfino, R. J., Staimer, N., Tjoa, T., Gillen, D. L., Schauer, J. J., & Shafer, M. M. (2013).
Airway inflammation and oxidative potential of air pollutant particles in a pediatric
asthma panel. Journal of Exposure Science & Environmental Epidemiology, 23(5),
466–73.
DeMarco, M. L., & Woods, R. J. (2011). From agonist to antagonist: structure and
dynamics of innate immune glycoprotein MD-2 upon recognition of variably
acylated bacterial endotoxins. Molecular Immunology, 49(1-2), 124–33.
Devleeschouwer, M. J., Cornil, M. F., & Dony, J. (1985). Studies on the sensitivity and
specificity of the Limulus amebocyte lysate test and rabbit pyrogen assays. Applied
and Environmental Microbiology, 50(6), 1509–11.
Diette, G. B., McCormack, M. C., Hansel, N. N., Breysse, P. N., & Matsui, E. C. (2008).
Environmental issues in managing asthma. Respiratory Care, 53(5), 602–15;
discussion 616–7.
Dinarello, C. A. (2004). Infection, fever, and exogenous and endogenous pyrogens: some
concepts have changed. Journal of Endotoxin Research, 10(4), 201–22.
Dockery, D. W. (2009). Health effects of particulate air pollution. Annals of
Epidemiology, 19(4), 257–63.
Domelsmith, L. N., Klich, M. A., & Goynes, W. R. (1988). Production of mannitol by
fungi from cotton dust. Applied and Environmental Microbiology, 54(7), 1784–90.
!
! 120
Donham, K. J. (2010). Community and occupational health concerns in pork production:
a review. Journal of Animal Science, 88(13 Suppl), E102–11.
Donham, K. J., Cumro, D., Reynolds, S. J., & Merchant, J. A. (2000). Dose-response
relationships between occupational aerosol exposures and cross-shift declines of
lung function in poultry workers: recommendations for exposure limits. Journal of
Occupational and Environmental Medicine / American College of Occupational and
Environmental Medicine, 42(3), 260–9.
Doreswamy, V., & Peden, D. B. (2011). Modulation of asthma by endotoxin. Clinical
and Experimental Allergy!: Journal of the British Society for Allergy and Clinical
Immunology, 41(1), 9–19.
Douwes, J., Thorne, P., Pearce, N., & Heederik, D. (2003). Bioaerosol health effects and
exposure assessment: progress and prospects. The Annals of Occupational Hygiene,
47(3), 187–200.
Douwes, J., Versloot, P., Hollander, A., Heederik, D., & Doekes, G. (1995). Influence of
various dust sampling and extraction methods on the measurement of airborne
endotoxin. Applied and Environmental Microbiology, 61(5), 1763–9.
Draing, C., Traub, S., Deininger, S., Mang, P., Möller, H. M., Manso, M., … von Aulock,
S. (2008). Polypropylene glycol is a selective binding inhibitor for LTA and other
structurally related TLR2 agonists. European Journal of Immunology, 38(3), 797–
808.
!
! 121
Dumas, M. D., Polson, S. W., Ritter, D., Ravel, J., Gelb, J., Morgan, R., & Wommack, K.
E. (2011). Impacts of poultry house environment on poultry litter bacterial
community composition. PloS One, 6(9), e24785.
Duquenne, P., Marchand, G., & Duchaine, C. (2013). Measurement of endotoxins in
bioaerosols at workplace: a critical review of literature and a standardization issue.
The Annals of Occupational Hygiene, 57(2), 137–72.
Dutkiewicz, J., Cisak, E., Sroka, J., Wójcik-Fatla, A., & Zając, V. (2011). Biological
agents as occupational hazards - selected issues. Annals of Agricultural and
Environmental Medicine!: AAEM, 18(2), 286–93.
Eduard, W., Pearce, N., & Douwes, J. (2009). Chronic bronchitis, COPD, and lung
function in farmers: the role of biological agents. Chest, 136(3), 716–25.
Eduard, W., Westby, M. H., & Larsson, L. (2004). Solubility of endotoxins from
Escherichia coli and Pseudomonas aeruginosa. American Journal of Industrial
Medicine, 46(4), 375–7.
Fishwick, D., Tate, P., Elms, J., Robinson, E., Crook, B., Gallagher, F., … Curran, A.
(2005). Respiratory symptoms, immunology and organism identification in
contaminated metalworking fluid workers. What you see is not what you get.
Occupational Medicine (Oxford, England), 55(3), 238–41.
!
! 122
Fornander, L., Graff, P., Wåhlén, K., Ydreborg, K., Flodin, U., Leanderson, P., …
Ghafouri, B. (2013). Airway symptoms and biological markers in nasal lavage fluid
in subjects exposed to metalworking fluids. PloS One, 8(12), e83089.
Foto, M., Plett, J., Berghout, J., & Miller, J. D. (2004). Modification of the Limulus
amebocyte lysate assay for the analysis of glucan in indoor environments. Analytical
and Bioanalytical Chemistry, 379(1), 156–62.
Fransman, W., McLean, D., Douwes, J., Demers, P. A., Leung, V., & Pearce, N. (2003).
Respiratory symptoms and occupational exposures in New Zealand plywood mill
workers. The Annals of Occupational Hygiene, 47(4), 287–95.
Furness, G., & Maitland, H. B. (1952). Studies on cotton dust in relation to byssinosis. I.
Bacteria and fungi in cotton dust. British Journal of Industrial Medicine, 9(2), 138–
45.
Geiser, M., & Kreyling, W. G. (2010). Deposition and biokinetics of inhaled
nanoparticles. Particle and Fibre Toxicology, 7(1), 2.
Ghio, A. J., Smith, C. B., & Madden, M. C. (2012). Diesel exhaust particles and airway
inflammation. Current Opinion in Pulmonary Medicine, 18(2), 144–50.
Gilbert, Y., Veillette, M., Meriaux, A., Lavoie, J., Cormier, Y., & Duchaine, C. (2010).
Metalworking fluid-related aerosols in machining plants. Journal of Occupational
and Environmental Hygiene, 7(5), 280–9.
!
! 123
Guarnieri, M., & Balmes, J. R. (2014). Outdoor air pollution and asthma. Lancet,
383(9928), 1581–92.
Gutsmann, T., Howe, J., Zähringer, U., Garidel, P., Schromm, a B., Koch, M. H. J., …
Brandenburg, K. (2010). Structural prerequisites for endotoxic activity in the
Limulus test as compared to cytokine production in mononuclear cells. Innate
Immunity, 16(1), 39–47.
Gwyer Findlay, E., & Hussell, T. (2012). Macrophage-mediated inflammation and
disease: a focus on the lung. Mediators of Inflammation, 2012, 140937.
Hansen, A. D. A., Rosen, H., & Novakov, T. (1984). The aethalometer — An instrument
for the real-time measurement of optical absorption by aerosol particles. Science of
The Total Environment, 36, 191–196.
Harting, J. R., Gleason, A., Romberger, D. J., Von Essen, S. G., Qiu, F., Alexis, N., &
Poole, J. A. (2012). Chronic obstructive pulmonary disease patients have greater
systemic responsiveness to ex vivo stimulation with swine dust extract and its
components versus healthy volunteers. Journal of Toxicology and Environmental
Health. Part A, 75(24), 1456–70.
Hartung, T., & Wendel, A. (1995). [Detection of Pyrogens using human whole blood].
ALTEX, 12(2), 70–75.
!
! 124
Hasiwa, N., Daneshian, M., Bruegger, P., Fennrich, S., Hochadel, A., Hoffmann, S., …
Hartung, T. (2013). Evidence for the detection of non-endotoxin pyrogens by the
whole blood monocyte activation test. ALTEX, 30(2), 169–208.
Health Council of the Netherlands (DECOS). (2010). Endotoxins. Health-based
recommended occupational exposure limit. The Hague: Health Council of the
Netherlands. Publication no. 2010/04OSH.
Heederik, D., Sigsgaard, T., Thorne, P. S., Kline, J. N., Avery, R., Bønløkke, J. H., …
Merchant, J. A. (2007). Health effects of airborne exposures from concentrated
animal feeding operations. Environmental Health Perspectives, 115(2), 298–302.
HEI Panel on the Health Effects of Traffic-Related Air Pollution (HEI). (2010). Traffic-
Related Air Pollution: A Critical Review of the Literature on Emissions, Exposure,
and Health Effects. HEI Special Report 17. Health Effects Institute, Boston, MA.
Helander, I., Saxén, H., Salkinoja-Salonen, M., & Rylander, R. (1982). Pulmonary
toxicity of endotoxins: comparison of lipopolysaccharides from various bacterial
species. Infection and Immunity, 35(2), 528–32.
Henderson, B., & Wilson, M. (1996). Cytokine induction by bacteria: beyond
lipopolysaccharide. Cytokine, 8(4), 269–82.
Hermann, C., Spreitzer, I., Schröder, N. W. J., Morath, S., Lehner, M. D., Fischer, W., …
Hartung, T. (2002). Cytokine induction by purified lipoteichoic acids from various
!
! 125
bacterial species--role of LBP, sCD14, CD14 and failure to induce IL-12 and
subsequent IFN-gamma release. European Journal of Immunology, 32(2), 541–51.
Hermann, C., von Aulock, S., Dehus, O., Keller, M., Okigami, H., Gantner, F., …
Hartung, T. (2006). Endogenous cortisol determines the circadian rhythm of
lipopolysaccharide-- but not lipoteichoic acid--inducible cytokine release. European
Journal of Immunology, 36(2), 371–9.
Hermann, C., von Aulock, S., Graf, K., & Hartung, T. (2003). A model of human whole
blood lymphokine release for in vitro and ex vivo use. Journal of Immunological
Methods, 275(1-2), 69–79.
Heyder, J. (2004). Deposition of inhaled particles in the human respiratory tract and
consequences for regional targeting in respiratory drug delivery. Proceedings of the
American Thoracic Society, 1(4), 315–20.
Hitchins, J., Morawska, L., Wolff, R., & Gilbert, D. (2000). Concentrations of
submicrometre particles from vehicle emissions near a major road. Atmospheric
Environment, 34(1), 51–59.
Hoffmann, S., Peterbauer, A., Schindler, S., Fennrich, S., Poole, S., Mistry, Y., …
Hartung, T. (2005). International validation of novel pyrogen tests based on human
monocytoid cells. Journal of Immunological Methods, 298(1-2), 161–73.
Holguin, F., Flores, S., Ross, Z., Cortez, M., Molina, M., Molina, L., … Romieu, I.
(2007). Traffic-related exposures, airway function, inflammation, and respiratory
!
! 126
symptoms in children. American Journal of Respiratory and Critical Care Medicine,
176(12), 1236–42.
Hoogerwerf, J. J., de Vos, A. F., Bresser, P., van der Zee, J. S., Pater, J. M., de Boer, A.,
… van der Poll, T. (2008). Lung inflammation induced by lipoteichoic acid or
lipopolysaccharide in humans. American Journal of Respiratory and Critical Care
Medicine, 178(1), 34–41.
Hoppin, J. A., Umbach, D. M., London, S. J., Alavanja, M. C. R., & Sandler, D. P.
(2003). Animal production and wheeze in the Agricultural Health Study:
interactions with atopy, asthma, and smoking. Occupational and Environmental
Medicine, 60(8), e3.
Hussell, T., & Bell, T. J. (2014). Alveolar macrophages: plasticity in a tissue-specific
context. Nature Reviews. Immunology, 14(2), 81–93.
Iwanaga, S. (2007). Biochemical principle of Limulus test for detecting bacterial
endotoxins. Proceedings of the Japan Academy. Series B, Physical and Biological
Sciences, 83(4), 110–9.
Jaakkola, M. S., Suuronen, K., Luukkonen, R., Järvelä, M., Tuomi, T., Alanko, K., …
Jolanki, R. (2009). Respiratory symptoms and conditions related to occupational
exposures in machine shops. Scandinavian Journal of Work, Environment & Health,
35(1), 64–73.
!
! 127
Jamison, J. P., & Lowry, R. C. (1986). Branchial challenge of normal subjects with the
endotoxin of Enterobacter agglomerans isolated from cotton dust. British Journal of
Industrial Medicine, 43(5), 327–31.
Janssen, N. A. H., Hoek, G., Simic-Lawson, M., Fischer, P., van Bree, L., ten Brink, H.,
… Cassee, F. R. (2011). Black carbon as an additional indicator of the adverse
health effects of airborne particles compared with PM10 and PM2.5. Environmental
Health Perspectives, 119(12), 1691–9.
Kawai, T., & Akira, S. (2009). The roles of TLRs, RLRs and NLRs in pathogen
recognition. International Immunology, 21(4), 317–37.
Kawai, T., & Akira, S. (2011). Toll-like receptors and their crosstalk with other innate
receptors in infection and immunity. Immunity, 34(5), 637–50.
Kayagaki, N., Wong, M. T., Stowe, I. B., Ramani, S. R., Gonzalez, L. C., Akashi-
Takamura, S., … Dixit, V. M. (2013). Noncanonical inflammasome activation by
intracellular LPS independent of TLR4. Science (New York, N.Y.), 341(6151), 1246–
9.
Keinänen, M. M., Martikainen, P. J., & Kontro, M. H. (2004). Microbial community
structure and biomass in developing drinking water biofilms. Canadian Journal of
Microbiology, 50(3), 183–91.
Kennedy, S. M., Christiani, D. C., Eisen, E. A., Wegman, D. H., Greaves, I. A.,
Olenchock, S. A., … Lu, P. L. (1987). Cotton dust and endotoxin exposure-response
!
! 128
relationships in cotton textile workers. The American Review of Respiratory
Disease, 135(1), 194–200.
Kikkert, R., Bulder, I., de Groot, E. R., Aarden, L. A., & Finkelman, M. A. (2007).
Potentiation of Toll-like receptor-induced cytokine production by (1-->3)-beta-D-
glucans: implications for the monocyte activation test. Journal of Endotoxin
Research, 13(3), 140–9.
Kindinger, I., Daneshian, M., Baur, H., Gabrio, T., Hofmann, A., Fennrich, S., …
Hartung, T. (2005). A new method to measure air-borne pyrogens based on human
whole blood cytokine response. Journal of Immunological Methods, 298(1-2), 143–
53.
Kindinger, I., Fennrich, S., Zuckert, B., Linselt, G., Aulock, S. Von, & Hartung, T.
(2003). Measurement of air-borne pyrogens by the in vitro pyrogen test ( IPT )
based on human whole blood cytokine response, 8(2003), 65–69.
Kirkhorn, S. R., & Garry, V. F. (2000). Agricultural lung diseases. Environmental Health
Perspectives, 108 Suppl , 705–12.
Kirychuk, S. P., Dosman, J. A., Reynolds, S. J., Willson, P., Senthilselvan, A., Feddes, J.
J. R., … Guenter, W. (2006). Total dust and endotoxin in poultry operations:
comparison between cage and floor housing and respiratory effects in workers.
Journal of Occupational and Environmental Medicine / American College of
Occupational and Environmental Medicine, 48(7), 741–8.
!
! 129
Kirychuk, S. P., Senthilselvan, A., Dosman, J. A., Juorio, V., Feddes, J. J. R., Willson, P.,
… Hurst, T. S. (2003). Respiratory symptoms and lung function in poultry
confinement workers in Western Canada. Canadian Respiratory Journal!: Journal
of the Canadian Thoracic Society, 10(7), 375–80.
Lai, P. S., & Christiani, D. C. (2013). Long-term respiratory health effects in textile
workers. Current Opinion in Pulmonary Medicine, 19(2), 152–7.
Laitinen, S., Linnainmaa, M., Laitinen, J., Kiviranta, H., Reiman, M., & Liesivuori, J.
(1999). Endotoxins and IgG antibodies as indicators of occupational exposure to the
microbial contaminants of metal-working fluids. International Archives of
Occupational and Environmental Health, 72(7), 443–50.
Lawniczek-Walczyk, A., Górny, R. L., Golofit-Szymczak, M., Niesler, A., & Wlazlo, A.
(2013). Occupational exposure to airborne microorganisms, endotoxins and β-
glucans in poultry houses at different stages of the production cycle. Annals of
Agricultural and Environmental Medicine!: AAEM, 20(2), 259–68.
Lee, S. K., & Ding, J. L. (2013). A perspective on the role of extracellular hemoglobin on
the innate immune system. DNA and Cell Biology, 32(2), 36–40.
Liebers, V., Brüning, T., & Raulf-Heimsoth, M. (2006). Occupational endotoxin-
exposure and possible health effects on humans. American Journal of Industrial
Medicine, 49(6), 474–91.
!
! 130
Liebers, V., Raulf-Heimsoth, M., & Brüning, T. (2008). Health effects due to endotoxin
inhalation (review). Archives of Toxicology, 82(4), 203–10.
Liebers, V., Raulf-Heimsoth, M., Linsel, G., Goldscheid, N., Düser, M., Stubel, H., &
Brüning, T. (2007). Evaluation of quantification methods of occupational endotoxin
exposure. Journal of Toxicology and Environmental Health. Part A, 70(21), 1798–
805.
Liebers, V., Stubel, H., Düser, M., Brüning, T., & Raulf-Heimsoth, M. (2009).
Standardization of whole blood assay for determination of pyrogenic activity in
organic dust samples. International Journal of Hygiene and Environmental Health,
212(5), 547–56.
Liebers, V., van Kampen, V., Bünger, J., Düser, M., Stubel, H., Brüning, T., & Raulf-
Heimsoth, M. (2012). Assessment of airborne exposure to endotoxin and pyrogenic
active dust using electrostatic dustfall collectors (EDCs). Journal of Toxicology and
Environmental Health. Part A, 75(8-10), 501–7.
Loh, L. C., Vyas, B., Kanabar, V., Kemeny, D. M., & O’Connor, B. J. (2006). Inhaled
endotoxin in healthy human subjects: a dose-related study on systemic effects and
peripheral CD4+ and CD8+ T cells. Respiratory Medicine, 100(3), 519–28.
MacDonald, J. M. (2014). Technology, Organization, and Financial Performance in U.S.
Broiler Production. Retrieved from
http://www.ers.usda.gov/media/1487788/eib126.pdf
!
! 131
Maeshima, N., & Fernandez, R. C. (2013). Recognition of lipid A variants by the TLR4-
MD-2 receptor complex. Frontiers in Cellular and Infection Microbiology, 3, 3.
Mallol, J., Solé, D., Asher, I., Clayton, T., Stein, R., & Soto-Quiroz, M. (2000).
Prevalence of asthma symptoms in Latin America: the International Study of
Asthma and Allergies in Childhood (ISAAC). Pediatric Pulmonology, 30(6), 439–
44.
Matheson, M. C., Benke, G., Raven, J., Sim, M. R., Kromhout, H., Vermeulen, R., …
Abramson, M. J. (2005). Biological dust exposure in the workplace is a risk factor
for chronic obstructive pulmonary disease. Thorax, 60(8), 645–51.
Mathiak, G., Kabir, K., Grass, G., Keller, H., Steinringer, E., Minor, T., … Neville, L. F.
(2003). Lipopolysaccharides from different bacterial sources elicit disparate
cytokine responses in whole blood assays. International Journal of Molecular
Medicine, 11(1), 41–4.
Matsui, E. C. (2014). Environmental exposures and asthma morbidity in children living
in urban neighborhoods. Allergy, 69(5), 553–8.
Matsui, E. C., Hansel, N. N., Aloe, C., Schiltz, A. M., Peng, R. D., Rabinovitch, N., …
Liu, A. H. (2013). Indoor pollutant exposures modify the effect of airborne
endotoxin on asthma in urban children. American Journal of Respiratory and
Critical Care Medicine, 188(10), 1210–5.
!
! 132
Mattsby-Baltzer, I., Lindgren, K., Lindholm, B., & Edebo, L. (1991). Endotoxin shedding
by enterobacteria: free and cell-bound endotoxin differ in Limulus activity. Infect.
Immun., 59(2), 689–695.
McConnell, R., Berhane, K., Yao, L., Jerrett, M., Lurmann, F., Gilliland, F., … Peters, J.
(2006). Traffic, susceptibility, and childhood asthma. Environmental Health
Perspectives, 114(5), 766–72.
McConnell, R., Wu, W., Berhane, K., Liu, F., Verma, G., Peden, D., … Fruin, S. (2013).
Inflammatory cytokine response to ambient particles varies due to field collection
procedures. American Journal of Respiratory Cell and Molecular Biology, 48(4),
497–502.
McCreanor, J., Cullinan, P., Nieuwenhuijsen, M. J., Stewart-Evans, J., Malliarou, E.,
Jarup, L., … Zhang, J. (2007). Respiratory effects of exposure to diesel traffic in
persons with asthma. The New England Journal of Medicine, 357(23), 2348–58.
Michel, O., Doyen, V., Leroy, B., Bopp, B., Dinh, D. H. P., Corazza, F., & Wattiez, R.
(2013). Expression of calgranulin A/B heterodimer after acute inhalation of
endotoxin: proteomic approach and validation. BMC Pulmonary Medicine, 13(1),
65.
Michel, O., Nagy, A. M., Schroeven, M., Duchateau, J., Nève, J., Fondu, P., & Sergysels,
R. (1997). Dose-response relationship to inhaled endotoxin in normal subjects.
American Journal of Respiratory and Critical Care Medicine, 156(4 Pt 1), 1157–64.
!
! 133
Miller, R. L., & Peden, D. B. (2014). Environmental effects on immune responses in
patients with atopy and asthma. Journal of Allergy and Clinical Immunology,
134(5), 1001–1008.
Milton, D. K., Wypij, D., Kriebel, D., Walters, M. D., Hammond, S. K., & Evans, J. S.
(1996). Endotoxin exposure-response in a fiberglass manufacturing facility.
American Journal of Industrial Medicine, 29(1), 3–13.
Mogensen, T. H. (2009). Pathogen recognition and inflammatory signaling in innate
immune defenses. Clinical Microbiology Reviews, 22(2), 240–73, Table of Contents.
Møller, A.-S. W., Ovstebø, R., Haug, K. B. F., Joø, G. B., Westvik, A.-B., & Kierulf, P.
(2005). Chemokine production and pattern recognition receptor (PRR) expression in
whole blood stimulated with pathogen-associated molecular patterns (PAMPs).
Cytokine, 32(6), 304–15.
Möller, W., Heimbeck, I., Hofer, T. P. J., Khadem Saba, G., Neiswirth, M.,
Frankenberger, M., & Ziegler-Heitbrock, L. (2012). Differential inflammatory
response to inhaled lipopolysaccharide targeted either to the airways or the alveoli in
man. PloS One, 7(4), e33505.
Montag, T., Spreitzer, I., Löschner, B., Unkelbach, U., Flory, E., Schwanig, M., &
Schneider, C. K. (2007). Safety Testing of Cell-based Medicinal Products':
Opportunities for the Monocyte Activation Test for Pyrogens. ALTEX, 24(April),
81–89.
!
! 134
Morgenstern, V., Zutavern, A., Cyrys, J., Brockow, I., Koletzko, S., Krämer, U., …
Heinrich, J. (2008). Atopic diseases, allergic sensitization, and exposure to traffic-
related air pollution in children. American Journal of Respiratory and Critical Care
Medicine, 177(12), 1331–7.
Muittari, A., Rylander, R., & Salkinoja-Salonen, M. (1980). Endotoxin and bath-water
fever. Lancet, 2(8185), 89.
Murat, J.-B., Grenouillet, F., Reboux, G., Penven, E., Batchili, A., Dalphin, J.-C., …
Millon, L. (2012). Factors influencing the microbial composition of metalworking
fluids and potential implications for machine operator’s lung. Applied and
Environmental Microbiology, 78(1), 34–41.
Nakata, T. (1993). Destruction of typical endotoxins by dry heat as determined using
LAL assay and pyrogen assay. Journal of Parenteral Science and Technology!: A
Publication of the Parenteral Drug Association, 47(5), 258–64.
Needham, B. D., & Trent, M. S. (2013). Fortifying the barrier: the impact of lipid A
remodelling on bacterial pathogenesis. Nature Reviews. Microbiology, 11(7), 467–
81.
Noss, I., Doekes, G., Thorne, P. S., Heederik, D. J. J., & Wouters, I. M. (2013).
Comparison of the potency of a variety of β-glucans to induce cytokine production
in human whole blood. Innate Immunity, 19(1), 10–9.
!
! 135
Ollinger, M., MacDonald, J. M., & Madison, M. (2005). Technological Change and
Economies of Scale in U.S. Poultry Processing. American Journal of Agricultural
Economics, 87(1), 116–129.
Ozesmi, M., Aslan, H., Hillerdal, G., Rylander, R., Ozesmi, C., & Baris, Y. I. (1987).
Byssinosis in carpet weavers exposed to wool contaminated with endotoxin. British
Journal of Industrial Medicine, 44(7), 479–83.
Paba, E., Tranfo, G., Corsetti, F., Marcelloni, A. M., & Iavicoli, S. (2013). Indoor
exposure to airborne endotoxin: a review of the literature on sampling and analysis
methods. Industrial Health, 51(3), 237–55.
Parker, D., & Prince, A. (2011). Innate immunity in the respiratory epithelium. American
Journal of Respiratory Cell and Molecular Biology, 45(2), 189–201.
Pearce, N., Pekkanen, J., & Beasley, R. (1999). How much asthma is really attributable to
atopy? Thorax, 54(3), 268–272.
Pomorska, D., Larsson, L., Skórska, C., Sitkowska, J., & Dutkiewicz, J. (2007). Levels of
bacterial endotoxin in air of animal houses determined with the use of gas
chromatography-mass spectrometry and Limulus test. Annals of Agricultural and
Environmental Medicine!: AAEM, 14(2), 291–8.
Poole, J. A., Dooley, G. P., Saito, R., Burrell, A. M., Bailey, K. L., Romberger, D. J., …
Reynolds, S. J. (2010). Muramic acid, endotoxin, 3-hydroxy fatty acids, and
ergosterol content explain monocyte and epithelial cell inflammatory responses to
!
! 136
agricultural dusts. Journal of Toxicology and Environmental Health. Part A, 73(10),
684–700.
Poole, J. A., & Romberger, D. J. (2012). Immunological and inflammatory responses to
organic dust in agriculture. Current Opinion in Allergy and Clinical Immunology,
12(2), 126–32.
Poole, S., Dawson, P., & Gaines Das, R. E. (1997). Second international standard for
endotoxin: calibration in an international collaborative study. Innate Immunity, 4(3),
221–231.
Pope, C. A., & Dockery, D. W. (2006). Health effects of fine particulate air pollution:
lines that connect. Journal of the Air & Waste Management Association (1995),
56(6), 709–42.
Pope, C. A., & Dockery, D. W. (2013). Air pollution and life expectancy in China and
beyond. Proceedings of the National Academy of Sciences of the United States of
America, 110(32), 12861–2.
Post, W., Heederik, D., & Houba, R. (1998). Decline in lung function related to exposure
and selection processes among workers in the grain processing and animal feed
industry. Occupational and Environmental Medicine, 55(5), 349–55.
Punsmann, S., Liebers, V., Lotz, A., Brüning, T., & Raulf, M. (2013). Ex vivo cytokine
release and pattern recognition receptor expression of subjects exposed to dampness:
!
! 137
pilot study to assess the outcome of mould exposure to the innate immune system.
PloS One, 8(12), e82734.
Punsmann, S., Liebers, V., Stubel, H., Brüning, T., & Raulf-Heimsoth, M. (2013).
Determination of inflammatory responses to Aspergillus versicolor and endotoxin
with human cryo-preserved blood as a suitable tool. International Journal of
Hygiene and Environmental Health, 216(4), 402–7.
Reynolds, S. J., Milton, D. K., Heederik, D., Thorne, P. S., Donham, K. J., Croteau, E.
A., … Larsson, L. (2005). Interlaboratory evaluation of endotoxin analyses in
agricultural dusts--comparison of LAL assay and mass spectrometry. Journal of
Environmental Monitoring!: JEM, 7(12), 1371–7.
Reynolds, S. J., Thorne, P. S., Donham, K. J., Croteau, E. A., Kelly, K. M., Lewis, D., …
Milton, D. K. (2002). Comparison of endotoxin assays using agricultural dusts.
AIHA Journal!: A Journal for the Science of Occupational and Environmental
Health and Safety, 63(4), 430–8.
Riedl, M., & Diaz-Sanchez, D. (2005). Biology of diesel exhaust effects on respiratory
function. The Journal of Allergy and Clinical Immunology, 115(2), 221–8; quiz 229.
Rimac, D., Macan, J., Varnai, V. M., Vucemilo, M., Matković, K., Prester, L., … Pavicić,
I. (2010). Exposure to poultry dust and health effects in poultry workers: impact of
mould and mite allergens. International Archives of Occupational and
Environmental Health, 83(1), 9–19.
!
! 138
Rivera-Mariani, F. E., Vysyaraju, K., Negherbon, J., Levetin, E., Horner, W. E., Hartung,
T., & Breysse, P. N. (2014). Comparison of the interleukin-1β-inducing potency of
allergenic spores from higher fungi (basidiomycetes) in a cryopreserved human
whole blood system. International Archives of Allergy and Immunology, 163(2),
154–162.
Robinson, C. L., Baumann, L. M., Gilman, R. H., Romero, K., Combe, J. M., Cabrera, L.,
… Checkley, W. (2012). The Peru Urban versus Rural Asthma (PURA) Study:
methods and baseline quality control data from a cross-sectional investigation into
the prevalence, severity, genetics, immunology and environmental factors affecting
asthma in adolescence in Peru. BMJ Open, 2(1), e000421.
Rylander, R. (2002). Endotoxin in the environment--exposure and effects. Journal of
Endotoxin Research, 8(4), 241–52.
Rylander, R., & Carvalheiro, M. F. (2006). Airways inflammation among workers in
poultry houses. International Archives of Occupational and Environmental Health,
79(6), 487–90.
Rylander, R., & Lundholm, M. (1978). Bacterial contamination of cotton and cotton dust
and effects on the lung. British Journal of Industrial Medicine, 35(3), 204–7.
Sahlander, K., Larsson, K., & Palmberg, L. (2010). Altered innate immune response in
farmers and smokers. Innate Immunity, 16(1), 27–38.
!
! 139
Saito, R., Cranmer, B. K., Tessari, J. D., Larsson, L., Mehaffy, J. M., Keefe, T. J., &
Reynolds, S. J. (2009). Recombinant factor C (rFC) assay and gas
chromatography/mass spectrometry (GC/MS) analysis of endotoxin variability in
four agricultural dusts. The Annals of Occupational Hygiene, 53(7), 713–22.
Sakwari, G., Mamuya, S. H. D., Bråtveit, M., Larsson, L., Pehrson, C., & Moen, B. E.
(2013). Personal exposure to dust and endotoxin in Robusta and Arabica coffee
processing factories in Tanzania. The Annals of Occupational Hygiene, 57(2), 173–
83.
Samadi, S., Wouters, I. M., & Heederik, D. J. J. (2013). A review of bio-aerosol
exposures and associated health effects in veterinary practice. Annals of Agricultural
and Environmental Medicine!: AAEM, 20(2), 206–21.
Schindler, S., Asmus, S., von Aulock, S., Wendel, A., Hartung, T., & Fennrich, S. (2004).
Cryopreservation of human whole blood for pyrogenicity testing. Journal of
Immunological Methods, 294(1-2), 89–100.
Schindler, S., Bristow, A., Cartmell, T., Hartung, T., & Fennrich, S. (2003). Comparison
of the reactivity of human and rabbit blood towards pyrogenic stimuli. Altex, 20(2),
59–63.
Schindler, S., Spreitzer, I., Löschner, B., Hoffmann, S., Hennes, K., Halder, M., …
Montag, T. (2006). International validation of pyrogen tests based on cryopreserved
human primary blood cells. Journal of Immunological Methods, 316(1-2), 42–51.
!
! 140
Si-Tahar, M., Touqui, L., & Chignard, M. (2009). Innate immunity and inflammation--
two facets of the same anti-infectious reaction. Clinical and Experimental
Immunology, 156(2), 194–8.
Simon, X., & Duquenne, P. (2014). Assessment of Workers’ Exposure to Bioaerosols in
a French Cheese Factory. The Annals of Occupational Hygiene.
Simpson, J. (1999). Comparative Personal Exposures to Organic Dusts and Endotoxin.
The Annals of Occupational Hygiene, 43(2), 107–115.
Simpson, J. L., Brooks, C., & Douwes, J. (2008). Innate immunity in asthma. Paediatric
Respiratory Reviews, 9(4), 263–70.
Smid, T., Heederik, D., Houba, R., & Quanjer, P. H. (1992). Dust- and endotoxin-related
respiratory effects in the animal feed industry. The American Review of Respiratory
Disease, 146(6), 1474–9.
Soukup, J. M., & Becker, S. (2001). Human alveolar macrophage responses to air
pollution particulates are associated with insoluble components of coarse material,
including particulate endotoxin. Toxicology and Applied Pharmacology, 171(1), 20–
6.
Spaan, S., Doekes, G., Heederik, D., Thorne, P. S., & Wouters, I. M. (2008). Effect of
extraction and assay media on analysis of airborne endotoxin. Applied and
Environmental Microbiology, 74(12), 3804–11.
!
! 141
Spaan, S., Heederik, D. J. J., Thorne, P. S., & Wouters, I. M. (2007). Optimization of
airborne endotoxin exposure assessment: effects of filter type, transport conditions,
extraction solutions, and storage of samples and extracts. Applied and
Environmental Microbiology, 73(19), 6134–43.
Spaan, S., Wouters, I. M., Oosting, I., Doekes, G., & Heederik, D. (2006). Exposure to
inhalable dust and endotoxins in agricultural industries. Journal of Environmental
Monitoring!: JEM, 8(1), 63–72.
Spencer, L. A., Bonjour, K., Melo, R. C. N., & Weller, P. F. (2014). Eosinophil Secretion
of Granule-Derived Cytokines. Frontiers in Immunology, 5, 496.
Spreitzer, I., Löschner, B., Schneider, C. K., Hanschmann, K.-M., & Montag, T. (2007).
10 years of experience with alternative pyrogen tests (monocyte activation tests).
Steenhof, M., Gosens, I., Strak, M., Godri, K. J., Hoek, G., Cassee, F. R., … Pieters, R.
H. H. (2011). In vitro toxicity of particulate matter (PM) collected at different sites
in the Netherlands is associated with PM composition, size fraction and oxidative
potential--the RAPTES project. Particle and Fibre Toxicology, 8, 26.
Stoddard, M. B., Pinto, V., Keiser, P. B., & Zollinger, W. (2010). Evaluation of a whole-
blood cytokine release assay for use in measuring endotoxin activity of group B
Neisseria meningitidis vaccines made from lipid A acylation mutants. Clinical and
Vaccine Immunology!: CVI, 17(1), 98–107.
!
! 142
Szponar, B., & Larsson, L. (2001). Use of mass spectrometry for characterising microbial
communities in bioaerosols. Annals of Agricultural and Environmental Medicine!:
AAEM, 8(2), 111–7.
Takeuchi, O., & Akira, S. (2010). Pattern recognition receptors and inflammation. Cell,
140(6), 805–20.
Teixeira, M. M., Almeida, I. C., & Gazzinelli, R. T. (2002). Introduction: innate
recognition of bacteria and protozoan parasites. Microbes and Infection, 4(9), 883–
886.
Theegarten, D., Sachse, K., Mentrup, B., Fey, K., Hotzel, H., & Anhenn, O. (2008).
Chlamydophila spp. infection in horses with recurrent airway obstruction:
similarities to human chronic obstructive disease. Respiratory Research, 9, 14.
Thorn, J. (2001). The inflammatory response in humans after inhalation of bacterial
endotoxin: a review. Inflammation Research!: Official Journal of the European
Histamine Research Society ... [et Al.], 50(5), 254–61.
Thorn, J., Beijer, L., & Rylander, R. (2001). Effects after inhalation of (1-->3)-beta-D-
glucan in healthy humans. Mediators of Inflammation, 10(4), 173–8.
Thorne, P. S., Perry, S. S., Saito, R., O’Shaughnessy, P. T., Mehaffy, J., Metwali, N., …
Reynolds, S. J. (2010). Evaluation of the Limulus amebocyte lysate and recombinant
factor C assays for assessment of airborne endotoxin. Applied and Environmental
Microbiology, 76(15), 4988–95.
!
! 143
Trabue, S., Scoggin, K., Li, H., Burns, R., Xin, H., & Hatfield, J. (2010). Speciation of
volatile organic compounds from poultry production. Atmospheric Environment,
44(29), 3538–3546.
Turvey, S. E., & Broide, D. H. (2010). Innate immunity. The Journal of Allergy and
Clinical Immunology, 125(2 Suppl 2), S24–32.
USDA Economic Research Service - Background. (2014). Retrieved from
http://www.ers.usda.gov/topics/animal-products/poultry-
eggs/background.aspx#.U9Ung1b7cYQ
Van der Meer, J. H. M., Netea, M. G., & Dinarello, C. A. (2009). Modulation of muramyl
dipeptide stimulation of cytokine production by blood components. Clinical and
Experimental Immunology, 156(3), 428–33.
Van Dooren, F. H., Duijvis, N. W., & te Velde, A. A. (2013). Analysis of cytokines and
chemokines produced by whole blood, peripheral mononuclear and
polymorphonuclear cells. Journal of Immunological Methods, 396(1-2), 128–33.
Van Kampen, V., Sander, I., Liebers, V., Deckert, A., Neumann, H.-D., Buxtrup, M., …
Bünger, J. (2014). Concentration of bioaerosols in composting plants using different
quantification methods. The Annals of Occupational Hygiene, 58(6), 693–706.
Van Vliet, P., Knape, M., de Hartog, J., Janssen, N., Harssema, H., & Brunekreef, B.
(1997). Motor vehicle exhaust and chronic respiratory symptoms in children living
near freeways. Environmental Research, 74(2), 122–32.
!
! 144
Venn, A. J., Lewis, S. A., Cooper, M., Hubbard, R., & Britton, J. (2001). Living near a
main road and the risk of wheezing illness in children. American Journal of
Respiratory and Critical Care Medicine, 164(12), 2177–80.
Venn, A., Yemaneberhan, H., Lewis, S., Parry, E., & Britton, J. (2005). Proximity of the
home to roads and the risk of wheeze in an Ethiopian population. Occupational and
Environmental Medicine, 62(6), 376–80.
Viegas, C., Carolino, E., Malta-Vacas, J., Sabino, R., Viegas, S., & Veríssimo, C. (2012).
Fungal contamination of poultry litter: a public health problem. Journal of
Toxicology and Environmental Health. Part A, 75(22-23), 1341–50.
Von Aulock, S., Hermann, C., & Hartung, T. (2003). Determination of the eicosanoid
response to inflammatory stimuli in whole blood and its pharmacological
modulation ex vivo. Journal of Immunological Methods, 277(1-2), 53–63.
WHO. (2005). WHO Air Quality Guidelines for Particulate Matter, Ozone, Nitrogen
Dioxide and Sulfur Dioxide. Retrieved November 29, 2014, from
http://whqlibdoc.who.int/hq/2006/WHO_SDE_PHE_OEH_06.02_eng.pdf
Wills-Karp, M. (1999). Immunologic basis of antigen-induced airway
hyperresponsiveness. Annual Review of Immunology, 17, 255–81.
Wouters, I. M., Douwes, J., Thorne, P. S., Heederik, D., & Doekes, G. (2002). Inter- and
intraindividual variation of endotoxin- and beta(1 --> 3)-glucan-induced cytokine
responses in a whole blood assay. Toxicology and Industrial Health, 18(1), 15–27.
!
! 145
Zhu, Y., Hinds, W. C., Kim, S., & Sioutas, C. (2002). Concentration and size distribution
of ultrafine particles near a major highway. Journal of the Air & Waste Management
Association (1995), 52(9), 1032–42.
Zucker, B., Scharf, P., & Kersten, C. (2006). Determination of the inflammatory potential
of bioaerosols from a duck-fattening unit by using a limulus amebocyte lysate assay
and human whole blood cytokine response. Journal of Veterinary Medicine. B,
Infectious Diseases and Veterinary Public Health, 53(4), 176–80.
!
! 146
Curriculum Vitae
Jesse Negherbon, P.E. Address: 239 S Exeter St, FL4 Baltimore, MD 21202 Phone: 607.280.1059 Email: [email protected] Education & Training
2015 PhD (ABD, expected January 2015) The Johns Hopkins University Environmental Health Sciences (GPA: 3.84/4.0) Baltimore, Maryland
Thesis: Whole Blood Assay Analysis of Immunostimulatory Constituents in Environmental Particulate Matter
Advisor: Patrick N. Breysse, PhD, CIH
2009 MEng Cornell University Engineering Management (GPA: 3.89/4.0) Ithaca, New York
2005 B.S. University of Alaska Anchorage (UAA) Civil Engineering (GPA: 3.61/4.0) Anchorage, Alaska
Professional Registrations & Certificates
• Registered Professional Engineer (Civil) - Utah #7752078-2202 • The Johns Hopkins University Risk Sciences & Public Policy Certificate
Research Projects
2014 - present Microbiome Analysis of Broiler Poultry House Particulate Matter PI: Patrick N. Breysse; Co-PI: Alan Scott
Comprehensive investigation of bacterial and fungal microbiome within broiler poultry house litter, feces, feed, and airborne particulate matter (PM). Next-generation DNA sequencing methods used for a metagenomic analysis of microbial diversity.
2013 - present Susceptibility to Asthma and Air Pollution in Peru: Traffic PM Exposure and Inflammatory Mediator Production in the Human Whole Blood System
PI: Nadia Hansel Study of asthmatic Peruvian children in Lima, using human whole blood assay methods to investigate each participant’s immunologic response patterns to standard endotoxin stimuli and respirable traffic PM sampled from the local environment.
2012 – 2014 Whole Blood Assay Assessment of Endotoxin and Non-Endotoxin Inflammatory Stimuli in Organic Particulate Matter
PI: Patrick N. Breysse Development and use of cryopreserved human whole blood assay methods to characterize and quantify the pro-inflammatory potential of respirable, thoracic, and inhalable PM samples from animal housing facilities (broiler poultry and dairy cow) and ambient urban Baltimore City.
!
! 147
2011 - 2012 Compositional Analysis of Particulate Matter from Rural Indian Cookstoves PI: Patrick N. Breysse
Sampling of particulate matter from kitchen air in rural Indian homes that utilize biomass cookstoves, and analysis of samples for metals and PAH content.
Professional Experience
2005 – 2010 CH2M HILL Anchorage, Alaska - Salt Lake City, Utah Role: Civil Engineer in Transportation Business Group Responsibilities: Engineering Planning, Design, and Project Management
Academic Teaching Experience 2013 Teaching Assistant Johns Hopkins Bloomberg School of Public Health Course: Environmental & Occupational Health, Law, & Policy 2012 Teaching Assistant Johns Hopkins Bloomberg School of Public Health Course: Food Production, Public Health, & the Environment 2009 Teaching Assistant Cornell University Course: Risk Analysis and Management 2008 Teaching Assistant Cornell University Course: Construction Planning and Operation Peer Review Publications Sussan TE, Ingole V, Kim JH, McCormick S, Negherbon J, Fallica J, Akulian J, Yarmus L, Feller-Kopman D, Wills-Karp M, Horton MR, Breysse PN, Agrawal A, Juvekar S, Salvi S, Biswal S. “Source of biomass cooking fuel determines pulmonary response to household air pollution.” Am J Respir Cell Mol Biol. 2014 Mar;50(3):538-48
Rivera-Mariani FE, Vysyaraju K, Negherbon J, Levetin E, Horner WE, Hartung T, Breysse PN. “Comparison of the interleukin-1β-inducing potency of allergenic spores from higher fungi (basidiomycetes) in a cryopreserved human whole blood system.” Int Arch Allergy Immunol. 2014;163(2):154-62. Posters & Presentations
Negherbon J, Benson E, Hartung T, Breysse P. “Whole Blood Assay Analysis of Agricultural Dust.” Chesapeake AIHA/ASSE PDC, Laurel, Maryland. 2014. Poster. Negherbon J, Rivera-Mariani FE, Williams DL, Benson E, Hartung T, Breysse P. “Quantification of the Total Proinflammatory Potential of Particulate Matter from Bioaerosol in a Broiler Poultry Facility.” International Society of Exposure Science, Basel, Switzerland. 2013. Poster. Negherbon J, Mihalic J, Breysse P. “Metals Analysis of PM from Rural Indian Kitchens” Johns Hopkins Center for Global Health Day. 2012. Poster.
!
! 148
Applicable Coursework
Epidemiologic Methods Principles of Immunology Biostatistics Airborne Particles Ventilation Controls Nano. Risk Analysis Molecular Epidemiology Food & Waterborne Disease Risk Communication Academic Awards
2014 Johns Hopkins Student Assembly Conference Award 2013 Cornelius W. Kruse Award 2011 Johns Hopkins Center for Global Health Field Research Award 2011 Indo-US Science and Technology Forum Award 2008 Cornell University Master of Engineering Fellowship