Issued October 2014 Page 1 of 16 TA Instruments What’s New in TRIOS Software What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software V3.1 document. What’s New in TRIOS Software V3.0 Refer to the What’s New in TRIOS Software V3.0 document. What’s New in TRIOS Software V2.6.2 Miscellaneous Fixes and Enhancements Rheology TTS fix for split signals ARES-G2/RSA-G2 fix for limited users conducting firmware upgrade ARES-G2 firmware update Revision AP. What’s New in TRIOS Software V2.6.1 Miscellaneous Fixes and Enhancements DHR: Fixed problems with Control panel locking up after setting the gap or running a test

Upload: others

Post on 03-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

TA InstrumentsWhat’s New in

TRIOS Software

Issued October 2014 Page 1 of 16

What’s New in TRIOS Software V3.1Refer to the What’s New in TRIOS Software V3.1 document.

What’s New in TRIOS Software V3.0Refer to the What’s New in TRIOS Software V3.0 document.

What’s New in TRIOS Software V2.6.2Miscellaneous Fixes and Enhancements• Rheology TTS fix for split signals• ARES-G2/RSA-G2 fix for limited users conducting firmware upgrade• ARES-G2 firmware update Revision AP.

What’s New in TRIOS Software V2.6.1Miscellaneous Fixes and Enhancements• DHR: Fixed problems with Control panel locking up after setting the gap or running a test

Page 2: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

What’s New in TRIOS Software V2.6New Product Support• Electrorheology (ER) Accessory Support for the Discovery Hybrid Rheometers: ER option for testing

ER fluids in an AC/DC electrical field in both oscillation and steady shear test modes. The ER option can test materials in parallel plate and concentric cylinder geometries.

• ARES-G2 Double Wall Ring (DWR) for Interfacial Rheology: Interfacial option for measuring the interfacial shear properties at liquid-liquid or liquid-gas interfaces using the double wall ring geometry.

Page 2 of 16

Page 3: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

• Disposable plates for DHR Dielectric Accessory: Used for curing thermosetting materials under vari-ous temperature profile while measuring dielectric and mechanical properties simultaneously.

• Partitioned Cone-Plate for ARES-G2: A geometry consisting of a plate and a ring for measuring high viscous elastic fluids such as polymer melts at high strain and strain rates while reducing the effect of secondary flows and sample fracturing. The partitioned plate can be paired with a plate or a cone.

Page 3 of 16

Page 4: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

Miscellaneous Fixes and Enhancements

General TRIOS• File > Open dialog: Preview and thumbnail support of last displayed graph in Windows Explorer File

> Open dialog. NOTE: Files must have been previously saved in TRIOS V2.6.

• Procedure naming improvement: A procedure can now be named while it is set up in an experiment. If you save a procedure and change the filename when you save it, you will receive a warning that the filename is different from your procedure name and you will be able to verify that they match.

• Graph X-Y values: In addition to the tool tip that appears when you hover the cursor over a point, when you click on a point, the value will appear on the Status Bar to the left of the clock. Once a point has been selected, the cursor keys can be used to move back and forth along the curve.

Page 4 of 16

Page 5: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

• Graph axis fonts: All axis variable fonts are linked and can be changed at the same time using font size setting on the Graph >Format tab. The tick mark label fonts are also linked and can be changed in the same way. Format font size also works for title, annotations, analysis, and any combination of selected text.

• Graph context menu: Draw removed and Show legend added• Derivative: Moved from Graph > Edit to Graph > Analysis tab

Discovery Hybrid Rheometer• New instrument firmware• New procedure step: Conditioning Electrorheology (available when accessory is installed)

• Zero gap by axial force added as an option• Transient data collection added to standard controlled stress oscillation• Global axial force conditions are now recorded in results file and can be viewed in the Parameters list

Page 5 of 16

Page 6: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

ARES-G2• New instrument firmware:

• WinCE - NK.bin • WinCe - NKLX.bin• AresG2 DSP - AresG2hb.ldr• RsaG2 DSP - RsaG2hb.ldr

• Enhanced Arbitrary Wave test procedure: The Arbitrary Waveshape test now allows the definition of the strain and temperature history by supplying one or more equations for strain and a temperature pro-file as a function of time. Up to four individual equations (defining a zone), each with a specified dura-tion, can be used in one step. The temperature profile consists of up to four isothermal or ramp zones.

Page 6 of 16

Page 7: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

• End of Test (EOT) Conditioning step: The End of Test (EOT) conditioning step is now available for the ARES-G2. The EOT defines the instruments settings for environmental system, transducer, motor and stage control after the procedure is completed. Note that the end of test condition step is a passive step and sets the conditions when the test is terminated, either normally, or by the user or the instrument. If you want the end of test conditions applied even if the test is terminated prematurely, the EOT conditioning block should be placed at the beginning of the procedure. If it is desired to change the EOT conditions based on when the procedure is terminated, more than one EOT can be used in a procedure. The position within the procedure in reference to the step when the procedure is terminated defines the EOT conditions that are applied. With the addition of this new step, the End of Test Options that were previously accessed from the TRIOS Options menu have been removed.

• Other enhancements and fixes:• Trim gap implemented for cones• Temperature ramps for fluid bath repaired

Discovery DSC• Minor bug fixes

Discovery TGA• Minor bug fixes

Page 7 of 16

Page 8: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

Analysis• Added ‘Best Fit’ option to model list for flow curves. Two labels are generated: one with R2 values for

all the applicable models, and one complete analysis for the one with the best value.

• TTS improvements:• TTS Wizard: Once suitable data has been loaded and graphed, the TTS ribbon becomes active.

The Wizard steps you through the procedure to generate a Master Curve.

• Curves can be added and removed after starting a TTS session• The Master Curve temperature is now included as part of the step name and can now be created at

any chosen temperature using the WLF or Arrhenius model to shift the data.

Page 8 of 16

Page 9: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

What’s New in TRIOS Software V2.5.2Miscellaneous Fixes and Enhancements• Thermal Discovery: Updated to stabilize Discovery thermal instruments and reduce incidents of USB-

related interruptions• Fixed bugs with Instrument (DSC and TGA) time synchronization with TRIOS• Fixed the blank screen with a cursor issue on the common cabinet.• Smoother TGA furnace motion at the up position• Auto sampler communication issues improved significantly• Fixed the TGA tare status stuck and weight calibration stuck issues

What’s New in TRIOS Software V2.5.1Miscellaneous Fixes and Enhancements• DHR: Updated embedded code V9.14• Rheology Procedures: Fixed issues saving images with procedures• Graph: Addressed issue with copying of the graph • File Importer: Added missing Orchestrator file importer (.TAD and RSD)• Thermal Discovery: Fixed issue where the sample name would be cleared if a procedure template was

selected after entering the sample name once the experiment starting running

Page 9 of 16

Page 10: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

What’s New in TRIOS Software V2.5Feature Enhancements

Dielectric Accessory Support for Discovery Hybrid RheometersTRIOS V2.5 includes support for the new Dielectric Accessory for Discovery Hybrid Rheometers.

Page 10 of 16

Page 11: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

Miscellaneous Fixes and Enhancements

General TRIOS• Thermal: History View now supported on a 64-bit PC with 32-bit Office installed• File Manager: Added button to collapse and expand documents within the File Manager

Data Representation and Analysis • Time Temperature Superpositioning (TTS) Enhancements

• Temperature displayed to only one decimal place in legend• Removed original file name from the default session name• Graph axis values displayed as 1, 10, 100 rather than 0, 1, 2• Support for dielectric data• Removed restriction on using specific variables• Graph settings and variables may now be changed during a TTS session• Added reference curve temperature to the master curve step name• Added *** to legend text for the reference curve • Colors and symbols no longer change when starting TTS session

• Modulus crossover model enhanced to search for multiple crossovers points• Default graph font settings updated to a larger font size

Page 11 of 16

Page 12: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

• Export and Copy: Option added to export at a fixed size (previous option, WYSIWYG, remains)

Discovery Hybrid Rheometer Instrument Control• Updated DHR firmware V9.13 to support Dielectric Accessory• Procedure setup

• Time can be entered in seconds or hh:mm:ss format and is set from the Display window in TRIOS Options

• Save Waveform option is enabled by default for Oscillation test types• Flow Sweep: Steady State Sensing parameters modified to be consistent with ARES-G2 imple-

mentation• Zero Gap: For DHR and AR-G2, the zero gap routine has been changed to remove the extra step of

positioning the geometries close together• Image (Camera) collection and display: Repaired bug on all operating systems

Page 12 of 16

Page 13: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

• Environmental control panel• Removed DISABLE function and incorporated with IDLE function• Added status of Environmental system

ARES-G2 and RSA-G2 Instrument Control• Updated ARES/RSA firmware

• Updated versions:

• ARES-G2/RSA-G2 V12.807

• ARES DSP/RSA DSP V12.803

• Power V12.807, LinCodr/Keypad V12.716, Motor PRT 12.625, Xducer PRT 12.625, FCO Phase Fire V12.714

• Experiment is aborted if LN2 or purge gas supply run out during active experiment• Static IP addressing for the instrument is supported

• Procedure setup• Save Waveform option is enabled by default for Oscillation test types• Time can be entered in seconds or hh:mm:ss format and is set from the Display window in TRIOS

Options

• Real Time Panel - Time/Points remaining: For time based procedure steps, the time remaining is shown in the control panel. For the other procedure step types the points remaining is shown.

• Temperature Ramp Iso Strain Test: Stage now correctly moves to compensate for the geometry expan-sion when selected

• RSA: Minimum sample thickness for tension and fibre clamps reduced

Page 13 of 16

Page 14: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

• When connecting to an ARES/RSA: The data from the instrument is no longer loaded by default if the instrument is idle. You can manually load by selecting the data from the File Manager.

• Image (Camera) collection and display: Repaired bug on all operating systems

Discovery DSC Instrument Control• Updated Discovery DSC firmware V5.4.0.21

• Instrument notifications messages were improved and clarified• Enhanced robustness of Table View for run sequence creation• Touch Screen

• A confirmation message is posted when Go to Next Segment is initiated from the Run Details view• Purge gas changes for GDM (gas delivery module) made for better handling of error and zero flow

conditions• Improved communication between TRIOS and instrument

NOTE: The firmware upgrade process takes more time (approximately 10 minutes) for this release and will reboot the instrument multiple times. TRIOS will display the progress and close when the process is complete.

Page 14 of 16

Page 15: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software

Discovery TGA Instrument Control• Updated Discovery TGA firmware V5.4.0.21

• Instrument notifications messages were improved and clarified• Touch Screen: When selecting only the Verification option for Weight Calibration, the calibration is no

longer performed as well• Heat Exchanger changes:

• Automatically turns on at start of experiment and turns off upon completion of the post test condi-tion

• If an experiment is manually stopped, the heat exchanger will remain on until 50°C• Whenever the evolved gas heater is enabled, the heat exchanger will be on

• Purge gas changes for GDM (gas delivery module) made for better handling of error and zero flow conditions

• Improved communication between TRIOS and instrument

NOTE: The firmware upgrade process takes more time (approximately 10 minutes) for this release and will reboot the instrument multiple times. TRIOS will display the progress and close when the process is complete.

Page 15 of 16

Page 16: What’s New in TRIOS Software V3.1 What’s New in TRIOS Software V3.0 What’s New … · 2000-08-31 · What’s New in TRIOS Software V3.1 Refer to the What’s New in TRIOS Software