April18,2018

WhatYouNeedtoKnowAboutCaliforniaCompliance– T20,T24andJA8

ChrisPrimous– VPOEMNationalAcctsandIndustryRelations

MAXLITEWEBINARS:

WHATYOUNEEDTOKNOWABOUTCALIFORNIACOMPLIANCE– T20,T24,&JA8

Topicstobecovered• Californialightingcomplianceoverview• UnderstandingTitle20• UnderstandingT24

• WhatisJA8?• Differencesinthetwoprograms• Findingcompliantproducts• Q&A

Presentedby:ChrisPrimous- VPofOEMNationalAcctsandIndustryRelations,MaxLite

Note:Linktopresentationmaterialwillbemadeavailabletoallparticipantssoonafterwebinar

2

Title20• Regulatesappliances soldinthestate• Clearlydefinesaveryspecificscopeofstate-regulatedappliances

• Applicabletoindividualproductssuchaslamps(bulbs),portableluminaires• Mandatoryforallappliancescoveredunderscopeofstateregulations.Suchproducts

mustbecertifiedtobelegallysoldinthestate.Heftyfinesmayapplyfornon-compliance

Title24• Buildingcode standardsforallnewconstructioninthestateofCalifornia

• Applicabletobuildings,notindividualproducts• Mandatoryfornewconstructionandremodels(allpermits).Enforcedbyinspectors• DifferingrequirementsforNon-ResidentialandResidentialconstruction

• NospecificindividualluminairerequirementsforNon-Residential• SomeResidential constructionrequiresstate-certified(JA8)lightingproducts

CALIFORNIALIGHTINGCOMPLIANCEMAXLITEWEBINARS:

3

TITLE20MandatoryApplianceEfficiencyRegulations– Lamps(bulbs),PortableLuminaires,Components

4

• Title20isCalifornia’sapplianceefficiencyregulations• IncludesFederalstandards(adoptedverbatim)forlightingproductscovered

byDepartmentofEnergyandadditionalStatestandardsrequiredforlightingandotherproducts

• currentregulations:http://www.energy.ca.gov/appliances/

• ManufacturersmustcertifyregulatedproductstotheCaliforniaEnergyCommissionpriortobeingsoldorofferedforsaleinthestateofCalifornia

• Failuretocertifyproductscanresultinfinesofupto$2,500pernon-compliantitem

WHATISCALIFORNIATITLE20?MAXLITEWEBINARS:

5

LIGHTINGPRODUCTSREGULATEDUNDERTITLE20

• CandelabraandIntermediateBaseIncandescentLamps• EmergencyLightingandSelf-ContainedLightingControls• TrafficSignalModulesandTrafficSignalLamps• Torchieres•MetalHalideLampFixtures

• FluorescentLampBallasts• GeneralServiceFluorescentLamps• IncandescentReflectorLamps•Med.BaseCFLs• GeneralServiceIncandescentLampsandModifiedSpectrumGeneralServiceIncandescentLamps

FederallyandCaliforniaregulated

AllproductsinbothlistsshownarerequiredtobecertifiedandregisteredinCECdatabase

• State-RegulatedIncandescentReflectorLamps• State-RegulatedGeneralServiceIncandescentLamps,GeneralServiceLamps,andModifiedSpectrumIncandescentLamps• GU-24BaseLamps• IlluminatedExitSigns• Self-ContainedLightingControls•MetalHalideLuminaires• Under-CabinetLuminaires(commercialofficeonly)• PortableLuminaires• GU-24Adaptors

California-onlyState-regulated

MAXLITEWEBINARS:

6

LAMPS(BULBS)REGULATEDUNDERTITLE20

3categoriesoflampsareregulatedbythestateofCaliforniaunderT20

• GeneralServiceLamps(GSLs)• INC,CFL,LED,OLEDlampswithmediumscrewbaseandintendedfor

generalserviceapplications• Onlyincludeslampswithoutput≥310lm,≤2,600lm• DoesnotincludeINCreflectorlamps,fluorescenttubes

• State-RegulatedLEDlamps(SLEDs)• LEDlampswithE12,E17,E26,GU24base(onlythesebases)• Includesdownlightretrofitswithbasesabove• Output≤2600lm• CCT=2200Kto7000K

• State-regulatedSmallDiameterDirectionalLamps(SDDLs)• 12V,24V,120VINC,CFL,LEDlampswithDia.≤2.25”• PinBaseorE26Base• Onlyincludeslampswithoutput≤850lmorWattage≤75W;andRated

Life>300hrs

MAXLITEWEBINARS:

7

GSLREGULATIONSUNDERTITLE20GeneralServiceLamp(GSL)definition/scope:

• Onlyincludeslampswithmed.screwbasesockets• INC,CFL,LED,OLED(alltechnologies)lampsintendedforgeneralserviceapplicationsand

capableofbeingoperatedat110Vto130V• Onlyincludeslampswithlumenoutput≥310lmand≤2,600lm• DoesnotincludeINCreflectorlamps,fluorescenttubes• IncludesmostINCANDESCENTomnimedscrewbaselamps

MAXLITEWEBINARS:

8

GSLREGULATIONSUNDERTITLE20GeneralServiceLamp(GSL)requirements:

• AppliestoallGSLsmanufacturedon/afterJanuary1,2018• RequirementsforGSLshavebeeninplacein2011.Increasedrequirementsin2018• Onlyincludeslampswithmedscrewbase (E26),output≥310lm, ≤2,600lm

Theseregulationsmeanmostmed.screwbaseIncandescentLampsneedtobe45lm/wtobesoldinCA

Effectivedate Min.RatedLifetime

Min.Efficacy Min. CRI

January1,2018 1,000 hours 45lm/w 80CRI(non-modified spectrum)75CRI(modifiedspectrum)

LampsthatshowamanufacturingdatecodepriortoJan.1,2018canstillbesoldinthestatewithoutmetingtheseregulations

MAXLITEWEBINARS:

9

GSLREGULATIONSUNDERTITLE20Products exempt from45lm/wandotherstaterequirementsforGeneralServiceLamps:• Lampswithoutmedscrewbase(E26),lampswithoutput< 310lmor>2,600lm• Linearfluorescent,incandescentreflectorlamps• Lampspackagedwithceilingfanlightkits• 22otherlamptypes

Note:Someoftheselampsarestillregulatedunderoneofothertwostateregulations:LEDLamps,SDDLs

• Appliancelamp • MarineLamp • Shatter-resistantlamp • Vibrationservicelamp

• Blacklightlamp • Marinesignal servicelamp • Signservicelamp • Gshapelamp(withdia >5”)

• Buglamp • Mineservicelamp • Silverbowllamp • Tshapelamp(≤40Worlength >10”)• Coloredlamp • Plantlightlamp • Showcaselamp

• Infraredlamp • Reflectorlamp • 3-waylamp • B,BA,CA,F,G16½,G-25,G30,S,M-14lampof≤ 40W• Left-handthreadlamp • Roughservicelamp • Trafficsignallamp

GSLregulationsareprimarilyforcommonmed.screwbaseomniINCandCFLs

MAXLITEWEBINARS:

10

LEDLAMP(BULB)REGULATIONSUNDERTITLE20

State-RegulatedLEDLamp(SLED)definition/scope:• LEDlampswithE12,E17,E26,GU24base(onlythesebases)• Includesdownlightretrofitswithbasesabove• Output≤2600lm• Capableofproducingwhitelightwith:

• CCT=2200Kto7000K• Duv between-0.012and0.012

MAXLITEWEBINARS:

11

LED LAMP(BULB)REGULATIONSUNDERTITLE20State-regulatedLEDlamps(SLEDs)manufacturedon/afterJanuary1,2018withoutput≥150lm(E12base)or≥200lm(otherbases)

• CRI≥82• R1throughR8values≥72

• PF≥0.7• RatedLife≥10,000hrs• Minimumefficacyandcompliancescoreperbelow:

RequirementsforState-RegulatedLEDlampsincreasetoTIER2forlampsmanufacturedon/afterJuly1,2019

Effectivedate Min.ComplScore Min.Efficacy

TIER1 January1,2018 282 68lm/w

TIER2 July1,2019 297 80lm/w

Example:68lm/w+(2.3x90CRI)=>275complscoreFAIL75lm/w+(2.3x90CRI)=>282complscorePASS

SLEDs aredefinedas:• LEDlampswithE12,E17,E26,GU24base

• Includesdownlightretrofitswithbasesabove

• Output≤2600lm• CCT=2200Kto7000K

MAXLITEWEBINARS:

12

DIRECTIONALLAMP(BULB)REGULATIONSUNDERTITLE20

State-RegulatedSmallDiameterDirectionalLamp(SDDL)definition/scope:• 12V,24V,120VINC,CFL,LEDlampswithDia.≤2.25”• ANSIPinBaseorE26Base• Onlyincludessmalldiameterdirectionallampswith:

• Output≤850lmorWattage≤75Wand

• RatedLife>300hrs

ExamplesofSmallDiameterANSIpinbaselampsincludeMR16lampswithGU10base(120V)andGU5.3(12V)

LampsthatmeetthisdefinitionareregulatedunderSDDLandNOTState-RegulatedLEDlamps

MAXLITEWEBINARS:

13

DIRECTIONALLAMP(BULB)REGULATIONSUNDERTITLE20State-regulatedSmallDiameterDirectionalLamps(SDDLs)manufacturedon/afterJanuary1,2018

RequirementsapplicabletoallINC,HALOGEN,CFL,LEDlampsThesenewrequirementswilleliminatemostINCandhalogenMR11,MR16,GU10,R/Par16lampssoldinCAinfavorofLED

Example:70lm/w+90CRI =>160compliancescoreFAIL75lm/w+90CRI=>165compliancescorePASS

Min.RatedLife Min.Efficacy

25,000hours 80lm/w

or

70lm/w +ComplianceScore≥165[Compliance Score=Efficacy+CRI]

SDDLs aredefinedas:• 12V,24V,120VINC,CFL,LEDlampswithDia.≤2.25”

• PinBaseorE26Base• Output≤850lmorWattage≤75W

and• RatedLife>300hrs

MAXLITEWEBINARS:

14

(forallluminairesmanufacturedon/afterJan.1,2010)

Requirements(mustmeetatleastone):1. Dedicatedfluorescentlampsocketconnectedtohighfreq.electronic

ballastwithintheportableluminaire2. BeequippedwithGU24socketandNOTratedforusewithINClamps3. BeanLEDluminaireorportableluminairewithanLEDLightEngine

withintegralheatsinkandcomplywithtableN-2

Criteria Requirement

LightOutput 200lm

Min.LEDLuminaireefficacy 29lm/w

Min. LEDLightEngineefficacy 40lm/w

Correlated ColorTemp(CCT) 2700Kto5000K

Min.ColorRenderingIndex (CRI) 75CRI

PowerFactor(forluminaireslabeledorsoldforresidentialuse)

0.7PF

TableN-2RequirementsforportableluminaireswithLEDLightEngines

PORTABLELUMINAIREREQUIREMENTSUNDERTITLE20

MAXLITEWEBINARS:

15

PORTABLELUMINAIREREQUIREMENTSUNDERTITLE20(forallluminairesmanufacturedon/afterJan.1,2010)

Requirements(mustmeetatleastone):4. BeequippedwithE12,E17,orE26baseand…

• Pre-packagedandsoldtogetherwithonescrew-baseCFLorLEDlampforeachsocket• CFLorLEDlampmustbecompatiblewithluminairecontrols• CFLsmustmeetENERGYSTARlampefficacyofDec.31,2008

• (50to65lm/w)• LEDlampsmustmeetmin.requirementsofcurrentT20

5. Beequippedwithoneormoresingle-endednon-screwbasehalogenlampsockets(lineorlowvoltage),dimmercontrolorhi/lowcontrols,andberatedforamaxof100W

*Note:• Exceptionsforartworkluminairesandportablewallmountadjustableluminaireswithmax

24”articulatedarm.• Portableluminaireswithinternalpowersuppliesmusthavezerostandbypowerwhenluminaireisoff

MAXLITEWEBINARS:

16

TITLE20LABELINGREQUIREMENTS

Note:SinceenforcementofT20isperdateofmanufacture,datecodesarecritical

(T202016,Section1607)

Applicabletoallregulatedappliances:• Manufacturer’sname,brandname,ortrademark• ModelNumber• DateofManufacture

• Indicatingyear,month,orsmaller(week)increment• Ifthedatecodeisnotreadilyunderstandabletothelayperson,themanufacturer

shallimmediately,onrequest,providethecodetoCEC• Informationcanbeoneachunitorunit’spackaging,orwheretheunitiscontainedina

groupofseveralunitsinasinglepackage,onthepackagingofthegroup

MAXLITEWEBINARS:

17

FAQSANDIMPORTANTNOTESABOUTT20• CeilingFanLightKits

• LampspackagedwithCeilingFanLightKitsdoNOT needtomeetT20• [Duetofederalrequirementsforceilingfanlightkits]

• CeilingFanLightKitsmuststillbecertifiedtoCECtobesoldinCA• CeilingFanLightKitswithscrewbasewouldstillrequirestate-certifiedJA8lightsourcestobeusedforT24installations

• SpecialapplicationsofLEDlamps• Therequirementsforstate-regulatedLEDlampsandsmall-diameterdirectionallampsareindependentofend-useorapplicationandarebasedonlyonlampcharacteristics.Alampiscoveredifitmeetsthedefinitionofastate-regulatedLEDlamporasmall-diameterdirectionallampperT20

• LEDLightEnginesandRetrofitKits• LEDEnginesandRetrofitkitsthatdoNOTincludeaE12,E12,E26,orGU24basedonotmeetthestate-regulatedlampdefinitionandthereforeNOTregulatedbyT20

MoreT20FAQs:http://www.energy.ca.gov/appliances/documents/state-regulated_lamps_FAQ.html#exemptions

MAXLITEWEBINARS:

18

FAQSANDIMPORTANTNOTESABOUTT20• LEDLuminairesandT20

• Withtheexceptionofportableluminaires,mostluminairesarenotregulatedbyT20,onlylamps(bulbs)andotherlightingcomponentsdescribed• Aluminairethatconnecttoabranchcircuitwithcordandplugisa“portableluminaire”andregulatedbyT20

• ColorTunableLEDlamps• ColortunableLEDlampsmustmeetrequirementsinthemodewhereitiscapableofproducingwhitelight• (withDuv between-0.012and0.012andCCTbetween2200Kand7000K)• Modesofoperationoutsideofthisrangedonotneedtomeetrequirements

MoreT20FAQs:http://www.energy.ca.gov/appliances/documents/state-regulated_lamps_FAQ.html#exemptions

MAXLITEWEBINARS:

19

TITLE20ENFORCEMENT(T202016,Section1608-1609)• Title20enforcementisbytheCaliforniaEnergyCommission(CEC)

• PeriodictestingandverificationmaybeperformedbyCEC• Itisillegaltosellorofferforsellinthestateanyregulatedproductthatisnot

certifiedtotheCECandlistedintheMAEDBS• Includesonlineretailersshippingintothestate

• Anypersonincludingaretailer,manufacturer,contractor,importerordistributor thatsellsoroffersforsellaregulatedappliancethatisnotlistedmaybesubjecttocivilpenaltiesforeachunitsoldorofferedforsale

• FourviolationsunderT20:• Failuretocertify,doesnotmeetstandard,failuretomark,providingfalse

information• Civilpenaltiescanbeassessedupto$2,500foreachviolation(perunitsold)

MAXLITEWEBINARS:

20

TITLE24NewConstructionBuildingCode– ResidentialandNon-ResidentialBuildings

21

• Buildingcoderequiredtobemetandverifiedbyinspectorspriortopermit• Requiredonlyfornew/remodelconstructionandcertainalterationswhere

buildingpermitsareneeded• T24notapplicabletoindividualproducts

• T24isachievedthroughcertifyinganoverallefficientbuildingapplication,notbyindividualproducts

• ProductsareNOTcertifiedasT24compliant,althoughcertainproductsmaybeusefulinsupportingT24buildingcompliance

• Non-Residential - ManywaystoachieveT24throughcontrolsandotherapplicationandcalculationmethods.Noindividualluminairecertificationsneeded.

• Residential– RequiresallluminairestobeHighEfficacy.HighEfficacymeanstheuseofJA8certifiedlightsourcesinmanycases.

• IndividualproductsarecertifiedtothestateandverifiedbycertificationdataregisteredonlinewithCaliforniaEnergyCommission(CEC)

• Mandatoryforallstate-regulatedappliances• Lamps(bulbs),portableluminaires,lightingcomponentsmustbecertifiedtothestateandregisteredondatabasetobesoldinCA

• Finesforregulatedproductssoldinthestatethatarenotcertified

TITLE20VSTITLE24

RegulatedproductsmustalsobeT20certifiedwhenusedinT24construction

MAXLITEWEBINARS:

22

WhatisCaliforniaTitle24?

Title24isCalifornia’sbuildingenergyefficiencystandards.Itisrequiredtobemetforanybuildingthatrequiresapermit.

LightinginstallationsinallnewlyconstructedbuildingsandadditionsandalterationsofexistingbuildingsmustmeetapplicableTitle24requirementsinordertoreceiveapermit.Complianceisverifiedbybuildinginspectors.

Title24isupdatedevery3yearsbytheCaliforniaEnergyCommission(CEC),currentapplicableversionisT242016.T242019iscurrentlyunderdevelopment.

CaliforniaT242016(T24-2016)becameeffectiveJanuary1,2017

WHATISCALIFORNIATITLE24?MAXLITEWEBINARS:

23

T24 NON-RESIDENTIALRequirements

• Includescertainmandatorymeasuressuchas:• Areacontrolstooperatelighting• Multi-levellightingrequirementsfordimmingbased

onsquarefootageandqtyofluminaires/lamps• Daylightingcontrolscapableofsheddingloadto

eliminateenergywaste

• Includesenergybudgetwithtwooptions:• Prescriptiveapproach:basedonLPD(lightingpower

density)• Performanceapproach:combinedmeasuresbased

onTDV(timedependentvaluation)

TITLE24- RESIDENTIALVSNON-RESIDENTIALREQUIREMENTST24RESIDENTIAL Requirements

• All lightinginstalledinresidentialconstructionmustbe“HighEfficacy”• HighEfficacyhascertainspecificdefinitionsinthestate

• Allluminairesmustinclude acompliantlightsourceatthetimeofinspection• Lightsourcesdonotnecessarilyneedtobeincludedin

thepackagingwiththefixture• LightsourcesorLuminairesmustbecertifiedandregistered

andappropriatelymarked“JA8-2016”or“JA8-2016-E”(elevatedtemp/enclosedrated)

Residentialrequirementsareproductspecific,Non-Residentialrequirementsconsidertheentirebuildingapplication

SinceNon-Resrequirementsfocusheavilyoncontrols,manybuilderscomplyusingdimmable/controllableluminaires

ManyResidentialapplicationscomplybyusingJA8certifiedlightsourcesinstandardsocketedluminaires

MAXLITEWEBINARS:

24

• T24lightingrequirementsforNon-Residentialapplicationsvariesbyspace,andcanbemetusingmanykindsofluminaireandcontrolscombinations• IndoorLightingRequirements:

• Dimming• Daylightingcontrol• OccupancySensor• Emergencybackup

• OutdoorLightingrequirements:• Uplight/Glarecontrol• AreaControl• Multi-LevelLighting• ShutoffControl• AutomaticDaylightingControl• SpecificLPDperzone

T24NON-RESIDENTIALREQUIREMENTS

Luminairescannotbe“T24Compliant”since,especiallyinNon-Residentialprojects,T24canbemetusingawidevarietyofluminairesandcontrols.

SomeproductssuchascontrolsandluminaireswithfeaturestosupportsomeoftheserequirementsMAYbemarketedas“SUPPORTST24COMPLIANCE”

ManywaystomeetT24Non-Resrequirementswithmostcontrols+luminaires

MAXLITEWEBINARS:

25

ScopeofResidentialRequirements• Allindoorandoutdoorlightingattachedtosinglefamilybuildings,withindwellingsinmulti-familybuildings.• Residentialspacesinnon-residentialbuildings• Includes:

• SingleFamilyBuildings,indoorandoutdoorlighting• HighRisemultifamilyresidentialunits• Hotelandmotelguestrooms• Firestationdwellings• Dormitoryandseniorhousingdwellings• Shedsandgaragesonresidentialsites

T24RESIDENTIALREQUIREMENTS

T24Residentialrequirementsareapplicabletomanyspacesotherthangeneralsingle-familyresidences

MAXLITEWEBINARS:

26

T24RESIDENTIALREQUIREMENTSAllpermanentlyinstalledlightingmustbe“HighEfficacy”

• T24isonlyapplicabletopermanentlyinstalledlighting• Permanentlyinstalledlighting definitionperT24:

• Attachedtowalls,ceilingsandcolumns• Attachedtotoporbottomofpermanentlyinstalledcabinets• Insidepermanentlyinstalledcabinets• Attachedtoceilingfans• Integraltoexhaustfans• Integraltogaragedooropeners• Partoftracklightingandflexiblelightingsystems

*Important Note: Permanently installed luminaires may have either plug-in or hardwired connection. A portable luminaire

(contains a cord/plug) that is attached or mounted as described above, will be subject to T24 regulations.

MAXLITEWEBINARS:

27

T24RESIDENTIALREQUIREMENTSAllpermanentlyinstalledlightingmustbe“HighEfficacy”

High EfficacyLightingLuminaires ofthistypeareautomaticallyclassifiedashighefficacy,andthereforeexemptfromneededstate-certifiedlightsources.

Allotherluminaires types,includingbelow,mustbeJA8certified integratedluminairesormusthaveaJA8certifiedlightsourceinthematthetimeofinspection

• Pin-based linearfluorescentorCFLlightsourcesusingelectronicballasts

• Pulse-startmetalhalide

• Highpressuresodium

• GU24socketscontaininglightsourcesotherthanLEDs(suchasCFL)

• Luminaireswithhardwiredhighfreqgeneratorandinductionlamp

• InseparableSSLluminairesthatareinstalledoutdoors

• InseparableSSLluminairescontainingcoloredlightsourcesthatareinstalledto

providedecorativelighting

• Alllightsources inceilingrecesseddownlights

• Recesseddownlightsalsomustcontainscrew-basesockets

• GU24socketscontainingLEDlightsources

• Allscrewbaseluminaires

• InseperableSSLluminairesinstalledindoors

• Anylightsourcenototherwiselistedinthistable

NoJA8CertificationRequired JA8CertificationRequired

MAXLITEWEBINARS:

28

• AllpermanentlyinstalledluminairesmustbeHighEfficacy• Allsuchluminairesthatcontainasocket,mustincludeaJA8compliantlightsource

• (excludesautomaticallyHighEfficacyluminaires)• E26socketsareok

• NolongeranyrequirementforGU24basesockets• JA8lightsourcesdoNOTnecessarilyneedtobeincludedinthepackagingwith

thefixture,butmustbeinplaceatthetimeofinspection• JA8lightsourcesshouldbemarkedas“JA8-2016”or“JA8-2016-E”forelevated

temperaturetestedsources• EnclosedLuminairesmayonlycontainlightsourcesmarked“JA8-2016-E”• Permanentlyinstallednightlightsshallconsumenomorethan5W

T24RESIDENTIALREQUIREMENTS

ThestateofCAestimatesT242016standardswillincreasenewhomecostby$2,700,butwillsave$7,400inenergyandmaintenancecostsover30years

MAXLITEWEBINARS:

29

• RecesseddownlightsandenclosedluminairesarerequiredtocontainaJA8compliantlightsourcethatmeetselevatedtemprequirements• Suchlightsourcesmustbemarked“JA8-2016-E”

• RecesseddownlightsshallNOTincludescrewbasesockets• MustalsobeIC/ATrated• Shallnotcontainlampsthatarelabeled“notforuseinenclosedor

recessedfixtures”

T24RESIDENTIALREQUIREMENTS

Buildersarerequiredtosubmitalightingscheduletotheoccupantsshowingallinteriorluminairesandlampsinstalled

MAXLITEWEBINARS:

30

• OutdoorResidentialLuminaires• Alloutdoorlightingonsinglefamilyresidentialbuildingsmustbehighefficacy• IftheoutdoorluminaireisaSSLInseparableLuminaire,itisautomaticallya“HighEfficacy”luminaire• Alloutdoorlightingmountedtosinglefamilyresidentialbuildingsisstillrequiredtobecontrolledbyoneofthefollowingcombinations:

1. Photocellandmotionsensor2. Photocellandtimeswitch3. Astronomicaltimeclock4. EMCSwithfeaturesofastronomicaltimeclock,doesnotallowtheluminaire

tobeonduringday,maybeprogrammedforautooffatnight

*Note:LightingthatisNOTattachedtoabuildingonasingle-familysiteisNOTregulatedbythestate(suchaslandscapelighting)

T24RESIDENTIALOUTDOORREQUIREMENTSMAXLITEWEBINARS:

31

• TheprimaryTitle242016BuildingEfficiencyStandardsdocumentationisapproximately289pgs• ThereisanaccompanyingseparateReferenceAppendicesdocumentof500+pgs• ItcontainstheResidentialAppendices(RA1-RA8),NonresidentialAppendices(NA1-NA4),andtheJointAppendices(JA1-JA10)

• JointAppendix8(JA8) oftheReferenceAppendicesprovidesallofthequalificationrequirementsforhighefficacylightsourcesinstalledtocomplywithsection150.0(k)ofthestandards• AllqualifyinglightsourcesmustbecertifiedtothestateofCaliforniaandregisteredontheCaliforniaEnergyCommission(CEC)database

WHATISJA8?MAXLITEWEBINARS:

32

JointAppendix8ofthe2016Title24BuildingEfficiencyStandards

Efficacy ≥45 lpw

PowerFactor ≥ 0.9PF

Color Rendering ≥ 90 CRI+R9≥50

CCT ≤4000K(engines), ≤ 3000K(lamps)

Dimming ≤10%

Flicker <30% forfreqlessthan200Hzat100%and20%oflightoutput(TestedperJA10)

Lifetime ≥15,000hours

Testing ENERGY STARElevatedTemperatureLifetestrequiredforallOmniLamps(>=10W)andenginesthatareNOTlabeled“notforuseinenclosedfixtures”or“notforuseinrecessedfixtures”

Labeling “JA8-2016”or“JA8-2016-E”(elevated temptest/enclosed).Exceptionsforengines/lamps withdia.lessthan1.0”anddecorativelampswithdia.lessthan2.0”

Summaryofmajorrequirements:

JA8REQUIREMENTSMAXLITEWEBINARS:

33

FAQSANDIMPORTANTNOTESABOUTT24JA8CertifiedLEDLightEngines

• JA8CertifiedLEDLightEnginesthatareREMOVABLE aretreatedjustlikelampsbythestateofCaliforniaforT24andcanbeusedtocertifyanyluminaireashighefficacy• LuminaireitselfwouldNOTneedtobeJA8certified

• NotethatJA8CertifiedLEDLightEngineshavecompleted6,000hrsoflifetestingsimilartoJA8lamps

• IftheLEDLightEngineisnotremovableandrequiresdestructionordamagetotheluminaire,theluminaireisdeemedanInseperableSSLLuminaireandmustbecertified

InseperableSSLLuminaires• InseperableSSLLuminairesthatutilizeLEDLightEnginesareNOTrequiredto

haveJA8CertifiedLEDLightEnginestogettheInseperableSSLLuminaireJA8Certified

• JA8Certificationoftheluminairemustmeetdimmable,flicker,andotherspecificationsbutcanutilizeLM80dataoftheLEDs.6,000hourslifetestnotneeded

MaxLiteoffersvariousJA8CertifiedLEDLightEngines:http://www.maxlite.com/products/led-light-engines/list

MAXLITEWEBINARS:

34

FAQSANDIMPORTANTNOTESABOUTT24CeilingFanLightKits,VentilationFans

• LightKitsinCeilingfansandVentilationFansaretreatedjustlikeluminairesandneedtobehighefficacyforT24(requirestechnologythatisautomaticallyhighefficacy,orlightkitincludesaJA8certifiedsourceatthetimeofinspection)

MAXLITEWEBINARS:

35

JA8COMPLIANTLAMPSVST20LAMPS

CEC Blueprint –Issue 117 Nov-Dec 2016

NotethatallJA8lampsregulatedbyT20mustbecertifiedtobothJA8and T20

JA8requirementsaremorestringentinmostcategoriesthanT20

MAXLITEWEBINARS:

36

HOWTOFINDCALIFORNIACOMPLIANTPRODUCTSListofT20andJA8certifiedproductscanbefoundonlineontheMAEDBSdatabaseonlineusingPUBLICSEARCHfeature

ModernizedApplianceEfficiencyDatabase(MAEDBS)

MAXLITEWEBINARS:

37

FINDMAXLITECALIFORNIACOMPLIANTPRODUCTS

MaxLiteCaliforniaCompliancelists• T20/JA8productfinder

http://www.maxlite.com/california-compliance

MAXLITEWEBINARS:

38

FINDMAXLITECALIFORNIACOMPLIANTPRODUCTSMaxLiteCaliforniaCompliancelists

http://www.maxlite.com/california-compliance

• Sortbyproducttypeandlistingtofindcurrently-availableT20,JA8,ENERGYSTAR,DLCproducts

• Featuresmultiplecategoryselectionstofindproductsthatarelistedtomultipleprograms

MAXLITEWEBINARS:

39

RESOURCESFORADDITIONALINFOFormoreinfoonCaliforniaTitle20http://www.energy.ca.gov/appliances/

QuestionsdirectlytoCaliforniaEnergyCommissionregardingT20appliances@energy.ca.gov

FAQonState-RegulatedLampshttp://www.energy.ca.gov/appliances/documents/state-regulated_lamps_FAQ.html

FormoreinfoonCaliforniaTitle24http://www.energy.ca.gov/title24

QuestionsdirectlytoCaliforniaEnergyCommissionregardingT24Title24@energy.ca.gov

MAXLITEWEBINARS:

40

MAXLITEWEBINARS:

QUESTIONS?

FORMOREINFORMATIONPLEASECONTACT:

[email protected]

Thanksforjoining!Pleaseusechatwindowtotypeanyquestionsdesiredtoanswerlive,orcontactmebelow:

Presentationcopywillbesenttoalluserssoon.

41