what are we measuring in eeg and meg? methods for dummies 2007 matthew longo
TRANSCRIPT
![Page 1: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/1.jpg)
What are we measuring in EEG and MEG?
Methods for Dummies 2007
Matthew Longo
![Page 2: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/2.jpg)
Basic Logic• Electrical activity of neurons produces
currents spreading through the head.
• These currents reach the surface of the scalp, in the form of voltage changes and magnetic fields, both of which can be measured non-invasively.
• Measured voltage changes at the scalp are called the electroencephologram (EEG).
• Measured magnetic fields at the scalp are called the magnetoencephologram (MEG).
![Page 3: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/3.jpg)
Electrical Activity in the Cortex• Action Potential
– Presynaptic
– Axonal
– Generally notmeasurable by EEG/MEG
• Excitatory postsynaptic potential (EPSP)– Postsynaptic
– Dendritic
– Measurable by EEG/MEG
![Page 4: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/4.jpg)
![Page 5: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/5.jpg)
• Apical dendrites are oriented in parallel along the cortical sheet
• Apical dendrites thought to contribute strongest signals measurable with EEG/MEG
• Axons are more randomly located, resulting in currents from presynaptic action potentials cancelling each other out
• Postsynaptic electrical activity (EPSP) sums, creating large “dipole”
![Page 6: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/6.jpg)
EEG and MEG Signals
• EPSPs of parallel dendrites in cortical columns creates:– Primary current (what we
want to know about)– Secondary/volume currents
• Measured by EEG• Influenced by intervening
tissue– Magnetic field
perpendicular to primary current
• Measured by MEG• Unaffected by intervening
tissue
![Page 7: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/7.jpg)
![Page 8: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/8.jpg)
Effects of Dipole Alignment
![Page 9: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/9.jpg)
Spatial Resolution
• Single synapse on dendrite contributes ~20 fA-m (femto = 10-15 = one quadrillionth)
• Empirical observations suggest EEG/MEG signals are typically ~ 10 nA-m (nano = 10-9 = one millionth)
• Therefore, typical EEG/MEG signals reflect summed activity of ~ 500,000 – 1,000,000 neurons
• ~ 1-5 mm2 of cortex forms lower bound of spatial resolution
• In practice, the inverse problem further limits the ability to spatially pinpoint EEG/MEG signals.
![Page 10: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/10.jpg)
MEG Signals
• MEG measures the fluctuations of frequency (Hz) and amplitude (T) of the brain magnetic signal
• 10 fT (10-15) to about several pT (10-12)
• Earth’s magnetic field ~ .5 mT
• Requires:– Preposterously sensitive magnetometer (SQUID)– Shielding from external noise
![Page 11: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/11.jpg)
The SQUID• Superconducting
Quantum Interference Device (SQUID)
![Page 12: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/12.jpg)
Pros and Cons of EEG & MEGEEG MEG
Signal magnitude Large signal (10 mV), easy to detect
Tiny signal (10 fT), difficult to detect
Cost Cheap Expensive
What does signal index? Measures secondary (volume) currents
Measures fields generated by primary currents
Signal purity Affected by skull, scalp, etc. Unaffected by skull, scalp, etc.
Temporal Resolution ~ 1 ms ~ 1 ms
Spatial Localization ~ 1 cm ~ 1 mm
Experimental Flexibility Allows some movement Requires complete stillness
Dipole Orientation Sensitive to tangential and radial dipoles
Sensitive only to tangential dipoles
![Page 13: What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo](https://reader036.vdocuments.us/reader036/viewer/2022062511/551ae08a5503465e7d8b4755/html5/thumbnails/13.jpg)
Further Reading
• Baillet et al. (2001). Electromagnetic brain mapping. IEEE Signal Processing Magazine.
• Del Gratta et al. (2001). Reports on the Progress of Physics, 64, 1759-1814.
• Hämäläinen et al. (1993). Review of Modern Physics, 65, 413-497.
• Murakami & Okada. (2006). Journal of Physiology, 575.3, 925-936.
• Nunez & Silberstein. (2000). Brain Topography, 13, 79-96.