west venture - nadlcorp.com/media/files/n/nadl/drilling-units/west-venture...west venture further...
TRANSCRIPT
West Venture
Further information: Tel: +47 51 30 90 00 • seadrill.com
GENERAL Design DP Drilling Vessel Built/year Hitachi/2000 Flag Panama Classification DNV Class notations 1A1, Drilling Vessel –
Drill (N),DYNPOS AUTRO, E0 HELDK, CRANE
MAIN DIMENSIONS/TECHNICAL Length x breadth 117 x 69 m Design water depth 1 800 m Min. water depth 70 m (Moored thruster
assist.) Drilling depth 9 000 m Variable load 5 700 mt (drilling) 5500 mt (survival) Propulsion 8 x 55 T thrusters Transit speed 10 knots Helideck S-92 Accommodation 114 persons, 57 Cabins STORAGE CAPACITIES Fuel 3108 m3 Drill water 1510 m3 Potable water 777 m3 Liquid mud 2455 m3 Base oil 250 m3 Brine 1876 m3 Barite/Bentonite 535 m3 Cement 321 m3 DRILLING EQUIPMENT Derrick 2 x MH ram rig Drawworks Ram cylinder Racking capacity 283 std. 5” DP
+ 6 std 8”DC + 6 std 9”DC
Top drive 2 x MH 650 L-HY-RR Rotary table 2 x 60 ½” Iron roughneck 2 x MH 1899 Motion compensation MH active/passive Riser tensioner 8 x 120 lbs Kips Guideline tensioner 8 x 7,57 T, Hydradyne
WELL CONTROL BOP Hydril - 18 3/4” - 15K Diverter Hydril FS21x60 - 500 psi C&K manifold WOM - 15K RISER SYSTEM Type Shaffer FT Length of joints 75 ft. Min. ID 19,75” K&C lines 3 “ ID - 15K BOP/RISER HANDLING BOP crane 2 x 60 t Riser crane 25,5 t gantry crane BOP skid 250 t Xmas tree crane 50 t Xmas tree skid 100 t MUD SYSTEM Mudpumps 4 x NOV 14-P-220 Mud pumps press.rating 7500 PSI Shale shakers 4 x Axiom AX-1 POWER Main engines 8 x Wartsila 12 V 32 LND Total power 32 MW Emergency power Wartsila 12 V 32 LND STATION KEEPING DP class DP 3 DP control system Kongsberg Anchor chain N/A Anchors N/A LIFTING EQUIPMENT Deck crane 2 x NOV/MAN Jib type Deck crane rating 60 t Auxiliary crane 1 x 5 t Cellerdeck Auxiliary crane 1 x 5 t drillfloor Pipe handling crane 1 x 6 t Pipedeck OFFLINE ACTIVITY CAPABILITY OTHER FEATURES
Page 1 of 1
TRACK RECORD WEST VENTURE
Country Operator Field / Well name Water depth (m)
Well depth MD (m)
Well type (appraisal, exploration, development HTHP etc.)
Well start date
Norway Ågotnes/CCB Transit 21.08.2015
Norway Statoil Troll/F-1 363,1 2887 m Change ot XMT
17.08.2015
Norway Statoil Troll/E-4 330,7 6400 m Development 13.06.2015
Norway Statoil Troll/F-6 329,7 4731 m P&A 27.05.2015
Norway Statoil Troll/D-5 338,23 3812 m Development 13.03.2015
Norway Statoil Troll / F-1 329.4 Development 02.12.2014
Norway Statoil Maintenance in CCB/Hjeltefjorden
Fix BOP wellhead connector
25.11.2014
Norway Statoil Troll / F-1 329.4 5459 Development 12.11.2014
Norway Statoil Troll / G-1 327.6 4070 m Development 07.09.2014
Norway Satoil CCB Yard stay 30.08.2014
Norway Statoil Fram Nord A-31 361.0 m 3641 m Top Completion
12.08.2014
Norway Statoil Troll / G-1 327,6 m 4070 m P&A 28.07.2014
Norway Statoil Troll / E-6 330,8 m 4062 m Development 12.03.2014
Norway Statoil Troll / H-2 318,1 m 1556 m Development 20.01.2014
Norway Statoil Troll / F-4 329,4 m 7720 m Development 24.08.2013
Norway Statoil Troll / H-2 318.1 m 5712 m Short PA 04.08.2013
Norway Statoil Troll / G-3 327.9 m 4288 m Change Vetco XMT
26.07.2013
Norway Statoil Troll / O-22 338,3 m Development 03.05.2013
Norway Statoil Troll / O-24 339.1 m 854,5 m Development 25.04.2013
Maintenance in Fensfjord
Change Annular
17.04.2013
Norway Statoil Troll / O-24 339,1 m 469 m Development 14.04.2013
Norway Statoil Troll / O-22 338,3 m 5290 m Development 10.04.2013
Norway Statoil Troll / D-6 337,4 m 2066,5 Development 12.01.2013
Norway Statoil Troll / E-5 330,7 m 721 m Development 06.11.2012
TRACK RECORD WEST VENTURE
Norway Statoil Troll / D-1 338,1 m 4525 m Development 06.12.2010
Norway Statoil Troll / Z-1 320 m 1760 m Development 30.11.2010
Norway Statoil Troll / Z-2. 317 m 2470 m Development 02.11.2010
Norway Statoil Troll / Z-1. 320 m 1760 m Development 12.10.2010
Norway Statoil Troll / N-22 348 m 6323 m Intervention 21.10.2012
Norway Statoil Troll / H-5 317.7 m 5060 M Development 02.09.2012
Norway Statoil Troll / E-5 330,7 m 3003 M Development 09.08.2012
Norway Statoil Troll / O-25 338.2 m 6739 M Development 24.07.2012
Norway Statoil Troll / K-14 319,4m 4544 M Development 13.07.2012
Norway Statoil Troll / S-41 341 m 1620 m Development 13.06.2012
Norway Statoil Troll / K-21 317,4 m 4775 m Intervention 04.06.2012
Norway Statoil Troll / N-22 348 m 6323 m Intervention 22.05.2012
Norway Statoil Troll / P-24 338.5 m 6815 m Development 05.05.2012
Norway Statoil Troll / I-12 316.2 m 1894 m Development 26.04.2012
Norway Statoil Troll / N-13 341 m 6665 m Development 12.04.2012
Norway Statoil Troll / D-8 336,9 m 4107 m Development 29.03.2012
Norway Statoil Troll / D-6 337,4 m 3672 m Development 04.03.2012
Norway Statoil Troll / H-5 316,3 m 4253 m Development 07.02.2012
Norway Statoil Troll / J-22 313,5 m 3581 m Development 24.01.2012
Norway Statoil Troll / K-14 319,4 m 1706 m Development 08.01.2012
Norway Statoil Troll / G-4 327,4 m 4100 m Development 21.12.2011
Norway Statoil Troll / J-22 313,5 m 5242 m Development 10.10.2011
Norway Statoil Troll / D-2 337,4 m 4602 m Development 23.09.2011
Norway Statoil Troll / D-8 336,9 m 3400 m Development 09.09.2011
Norway Statoil Troll / Q-12 335,1 m 6068 m Development 29.07.2011
Norway Statoil Troll / I-12 316,2 m 4777 m Development 09.07.2011
Norway Statoil Troll / K-12 319,4 m 5690 m Development 28.06.2011
Norway Statoil Troll / Y-24 331,5 m 3478 m Development 16.06.2011
Norway Statoil Troll / N-13 341 m 4963 m Development 08.06.2011
Norway Statoil Troll / S-14 342,4 m 5071 m Development 27.05.2011
Norway Statoil Troll / J-22 313,5 m 5242 m Development 13.05.2011
Norway Statoil Troll / G-4 327,4 m 4100 m Development 02.05.2011
Norway Statoil Troll / D-2 337,4 m 4602 m Development 11.04.2011
Norway Statoil Troll / G-3 327,9 m 4288 m Development 28.03.2011
Norway Statoil Troll / E-4 330,7 m 4000 m Development 17.02.2011
Norway Statoil Troll / O-23 338,3 m 5166 m Development 22.01.2011
Norway Statoil Troll / K-12 319 m 5690 m Development 30.12.2010
TRACK RECORD WEST VENTURE
Norway Statoil Rig to Fensfjord to pick up 2xFMC X-TRE
Development 11.10.2010
Norway Statoil Troll / Z-1 320 m Development 03.10.2010
Norway Statoil Troll / Z-2 317 m Development 22.09.2010
Norway Statoil Troll / P-13 336,2 m 336,2 m Development 07.09.2010
Norway Statoil Troll / S-14 352,4 m 5071 m Development 10.08.2010
Norway Statoil Fensfjord/Rep.crane/ thruster
Development 08.08.2010
Norway Statoil Troll / Y-23 331,5 m 4999,5 m
Development 23.07.2010
Norway Statoil Troll / O-21 338,3 m 338,2 m Development 14.07.2010
Norway Statoil Troll / O-26 338,2 m 338,2 m Development 28.06.2010
Norway Statoil Troll / G-3 327,9 m 4288 m Development 18.06.2010
Norway Statoil O-26 Move to Fensfjord demob.Vetco eqpm.
Development 15.06.2010
Norway Statoil Troll / G-3 327,9 m 4288 m Development 10.06.2010
Norway Statoil Class 2010 West Venture in ØLEN
Development 21.04.2010
Norway Statoil Troll / P-13 336,2 m 5333 m Development 14.03.2010
Norway Statoil Troll / F-1 330 m 330 m Development 10.03.2010
Norway Statoil Troll / M-24 354 m 5984 m Development 05.02.2010
Norway Statoil CCB. INSTALL FMC EQUIPMENT
Development 26.01.2010
Norway Statoil Troll / F-1 330 m 5400 m Development 12.01.2010
Norway Statoil Troll / H-3 318 m 5888 m Development 17.10.2009
Norway Statoil Troll / H-6 315,8 m 5133 m Development 03.09.2009
Norway Statoil Troll / H-3 316 m 5888 m Development 28.08.2009
Norway Statoil Troll / Y-23 331,5 m 4999,5 m
Development 09.08.2009
Norway Statoil Troll / H-6 315,8m 5133 m Development 20.07.2009
Norway Statoil Troll / X-22 327,9 m 5377 m Development 22.04.2009
Norway Statoil Troll / Y-13 333,8 m 4445 m Development 10.04.2009
Norway Statoil Troll / X-22 327,9 m 5377 m Development 18.03.2009
Norway Statoil/Hy. Troll / F-1 330 m 5400 m Development 24.02.2009
Norway Statoil/Hy. Troll / S-23 342,4 5071 m Development 09.02.2009
Norway Statoil/Hy. Troll / H-6 315,8 m 5133 m Development 26.01.2009
Norway Statoil/Hy. Troll / G-6 328 m 4574 m Development 28.12.2008
Norway Statoil/Hy. Troll / M-24 354,2 m 2200 m Development 06.11.2008
Norway Statoil/Hy. Troll / D-1 338,1 4521 m Development 28.09.2008
Norway Statoil/Hy. Troll / F-6 329,7 m 5271 m Development 24.06.2008
Norway Statoil/Hy. Troll / G-6 328 m 4574 m Development 27.05.2008
Norway Statoil/Hy. Fensfjorden Repair 21.05.2008
Norway Statoil/Hy. DP & ESD tests Test 19.05.2008
Norway Statoil/Hy. Troll / E-1 331 m 4613 m Development 11.10.2007
Norway Statoil/Hy. Troll / J-24 313,5 m 4891,5 m
Development 23.09.2007
Norway Statoil/Hy. Troll / X-12 338,7 m 5532 m Development 26.07.2007
Norway Statoil/Hy. Troll / D-7 337,5 m 5712,5 Development 07.07.2007
Norway Statoil/Hy. Troll / X-12 334,5 m 4837 m Development 20.06.2007
Norway Statoil/Hy. Troll / Q-21 338,7 m 5532 m Development 21.05.2007
TRACK RECORD WEST VENTURE
Norway Statoil/Hy. Troll / K-24 317,4 Development 08.05.2007
Norway Hydro Troll / G-1 327,6 m 5524 m Development 14.01.2007
Norway Hydro Troll / D-7 337,5 m 5712,5 m
Development 15.12.2006
Norway Hydro BOP+Loop Fensfj.
Development 08.12.2006
Norway Hydro Troll / X-12 334,5 m 4837 m Development 13.10.2006
Norway Hydro Troll / X-23. 329 m 7230 m Development 14.09.2006
Norway Hydro Troll / G-01 327,6 m 4070 m Development 15.07.2006
Norway Hydro DP TEST Development 13.07.2006
Norway Hydro Troll / N-11 341 m 5676 m Development 24.12.2005
Norway Hydro BOP Maint. Fensfj.
Development 10.12.2005
Norway Hydro Troll / H-2 318,1 m 3500 m Development 25.08.2005
Norway Hydro Troll / N-11 341 m 4277 m Development 09.07.2005
Norway Hydro Troll / I-14 316,2 m 7703 m Development 04.04.2005
Norway Hydro Troll / I-11 316,2 m 4448,5 m
Development 28.03.2005
Norway Hydro YARD STAY Development 11.03.2005
Norway Hydro Troll / J-24 313,5 m 4617,5 m
Development 27.02.2005
Norway Hydro Troll / F-5 329,2 m 6110 m Development 12.02.2005
Norway Hydro Troll / N-11 341 m 950 m Development 03.02.2005
Norway Hydro ORIENTERINGSTEST
Development 29.01.2005
Norway Hydro Troll / K-24 317,4 m 6338 m Development 12.09.2004
Norway Hydro Troll / O-14 336,2 m 6327 m Development 14.05.2004
Norway Hydro Troll / Q-21 338,7 m 5532 m Development 21.03.2004
Norway Hydro Troll / N-24 346,9 m 5440 Development 14.03.2004
Norway Hydro RIG REPAIR Development 08.03.2004
Norway Hydro Troll / N-24 346,9 4107 m Development 03.11.2003
Norway Hydro Troll / K-11 319,4 m 5520 m Development 24.08.2003
Norway Hydro Troll / Q-11 335,1 m 5610 m Development 13.06.2003
Norway Hydro Troll / S-22 341 m 6233 m Development 08.06.2003
Norway Hydro Troll / Q-11 335,1 m 5610 m Development 05.06.2003
Norway Hydro S-14 AH 342,4 m 5071 m Development 30.05.2003
Norway Hydro Troll / L-12 324,4 m 5888 m Development 22.03.2003
Norway Hydro Troll / I-32 312,9 m 5016 m Development 25.01.2003
Norway Hydro Troll / P-22 337,6 m 5311 m Development 23.01.2003
Norway Hydro Troll / L-22 328,5 m 5016 m Development 26.12.2002
Norway Hydro IN SHORE STAY Development 07.12.2002
Norway Hydro Troll / L-22 328,5 m 2690m Development 23.09.2002
Norway Hydro Troll / X-12 334,5 m 5382 m Development 17.08.2002
Norway Hydro Troll / X-21 327,9 4720 m Development 27.07.2002
Norway Hydro Troll 31/5-5 318 m 1930 m Development 18.07.2002
Norway Hydro Troll / N-21 346,9 m 5500 m Development 13.07.2002
Norway Hydro Troll / X-21 327,9 m 4720 m Development 28.06.2002
Norway Hydro Troll / E-6 330,8 m 3355 m Development 23.06.2002
Norway Hydro Troll / H-3 318 m 5615 m Development 22.06.2002
Norway Hydro Troll / H-5 316,3 m 4241 m Development 22.06.2002
Norway Hydro Troll / H-4 316,6 3938 m Development 20.06.2002
Norway Hydro Troll / D-8 338,4 m 3400 m Development 18.06.2002
Norway Hydro Troll / D-7 337,5 m 3900 m Development 17.06.2002
Norway Hydro Troll / D-6 337,4 m 3672 m Development 17.06.2002
TRACK RECORD WEST VENTURE
Norway Hydro Troll / D-5 337,4 2055 m Development 16.06.2002
Norway Hydro Troll / D-1 338,1 m 4342 m Development 14.06.2002
Norway Hydro Troll / D-2 337,4 m 4602 m Development 11.06.2002
Norway Hydro Troll / P-11 336,2 m 4519 m Development 06.06.2002
Norway Hydro Troll / P-21 337,6 m 5303 m Development 30.01.2002
Norway Hydro Troll / P-23 337,6 4916 m Development 28.01.2002
Norway Hydro Troll / P-21 337,6 m 2537 m Development 23.01.2002
Norway Hydro Troll / P-22 337,6 5311 m Development 21.01.2002
Norway Hydro Troll / O-12
336,2 4880,5 m
Development 04.01.2002
Norway Hydro Troll / X-14 332,9 5238 m Development 11.08.2001
Norway Hydro Troll / X-22 327,9 5100 m Development 10.07.2001
Norway Hydro Troll / X-21 327,9 m 4720 m Development 08.07.2001
Norway Hydro Troll / X-22 327,9 m 5100 m Development 03.07.2001
Norway Hydro Troll / K-21 317,4 4857 m Development 05.05.2001
Norway Hydro Troll / N-12 341 m 4880 m Development 14.03.2001
Norway Hydro Troll / X-11 332,9 m 4837 m Development 15.01.2001
Norway Hydro Troll / N-13 341 m 4963 m Development 28.11.2000
Norway Hydro Troll / Y-13
335 m 4227,5 m
Development 30.09.2000
Norway Hydro Troll / M-14 345,1m 4985 m Development 15.05.2000
Norway Hydro lO-11 Development 03.04.2000
Norway Hydro A-18 340 m 2005 m Development 24.02.2000
West Venture
Utility stasjon pipedeck aft. ( 1 )
Electrical: Tabell utvides med antall linjer etter behov
Instrument:
Telecom:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Cabinet. Area
*
Tavle/
utgang
(V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr Modul
No/Room
Main
EN2872
4011+1B
690 50 3 I 63 Rekkeklemme JB23720011
Main
EN2872
4003+11
400 50 3 S 63 Rekkeklemme JB23720003
Main
EH2872
4004
PDB211
230 50 1 S 16 Ceag Ex
stikkontakt
EH2872
4004.44
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure Potensialfree
contact
IB28120050 Alarm ingen aksjoner ABB ICMS tag nr
XLA28125018
Fire Potensialfree
contact
IB28120050 Alarm ingen aksjoner ABB ICMS tag nr
XLA28125017
Gas Potensialfree
contact
IB28120050 Alarm ingen aksjoner ABB ICMS tag nr
XLA28125016
Other
ESD battery 2Systems
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA A/B 100V JBP24220061
Norse electronic
model 110100
PA sentral
Telephone Telefonsignal Alcatel lucent
omnivista 4760
Tlf.sentral 5352
Utilities:
Lifting capacity offshore cranes:
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other
West Venture
Utility stasjon testområdet. ( 2 )
Electrical: Tabell utvides med antall linjer etter behov
Instrument:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Cabinet
Area
*
Tavle/
utgang
(V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr Modul
No/Room
No
Main EN1
871
4011+1B
690 50 3 No I 63 Rekkeklemme JB13710012
Main EN1
871
4003+1I
400 50 3 No S 63 30 Rekkeklemme JB13710002
Main EH1
4004
PDB111
230 50 1 Yes S 16 30 CEAG Ex
stikkontakt
EH1871
4004.36
Alternator
Dist.
Panel
440 60 3 No S 63 Rekkeklemme JB13710021
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure Potensialfree
contact
Rekkeklemme
IB18110051
ABB ICMS tag nr
XLA18115015
Fire Potensialfree
contact
Rekkeklemme
IB18110051
ABB ICMS tag nr
XLA18115014
Gas Potensialfree
contact
Rekkeklemme
IB18110051
ABB ICMS tag nr
XLA18115013
Other
ESD battery 1Systems
Telecom:
Utilities:
Lifting capacity offshore cranes:
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA ??W1100V Tilkoblingspunkt ?
Junction box nr ?
ABB ICMS tag nr ?
Telephone Telefonsignal Tilkoblingspunkt ?
telefon nr ?
GA
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other
West Venture
Utility stasjon stb.boxdrager. ( 3 )
Electrical: Tabell utvides med antall linjer etter behov
Instrument:
Telecom:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Cabinet
Area
*
Tavle/
utgang
(V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr Modul
No/Room
No
Main
EN1871
4011+
01B
690 50 I 63 Rekkeklemme JB13710013
Main
EN1871
4003+1I
400 50 S 63 Rekkeklemme JB13710004
Main
EN1871
4004
PDB111
230 50 S 16 Ceag Ex
stikkontakt
EH1871
4004.36
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure Potensialfree
contact
Rekkeklemme
IB18110052
ABB ICMS tag nr.
XLA18115012
Fire / gas Potensialfree
contact
Rekkeklemme
IB18110052
ABB ICMS tag nr.
XLA18115011
Gas Potensialfree
contact
Rekkeklemme
IB18110052
ABB ICMS tag nr.
XLA18115010
Other
ESD battery 1Systems
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA A/B 100V Rekkeklemme
JBP14210063
Nor Electronics PA sentral
Telephone Telefonsignal Rekkeklemme
JBP14210063
Telefonsentral 5351
Utilities:
Lifting capacity offshore cranes:
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other
West Venture
Utility stasjon boredekk main. ( 4 )
Electrical: Tabell utvides med antall linjer etter behov
Instrument:
Telecom:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Cabinet
Area
*
Tavle/
utgang
(V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr Modul
No/Room
No
Main
EN1871
4011+1B
690 50 3 I 63 Rekkeklemme JB13710014
Main
EN1871
4003+1I
400 50 3 S 63 Rekkeklemme JB13710005
Main EH1
8714004
PDB111
230 50 1 S 16 Ceag Ex
stikkontakt
EH18714004
PDB111
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure
Fire / gas
Gas
Other
ESD battery 1Systems
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA
Telephone
GA
Utilities:
Lifting capacity offshore cranes:
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other
West Venture
Utility stasjon boredekk aux. ( 5 )
Electrical: Tabell utvides med antall linjer etter behov
Instrument:
Telecom:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Cabinet Area
*
Tavle/
utgang
(V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr Modul
No/Room
No
Main
EN1871
4011+1B
690 50 I 63 Rekkeklemme JB13710015
Main
EN1871
4003.1I
400 50 S 63 Rekkeklemme JB13710006
Main EH1
8714004
PDB111
230 50 S 16 Ceag Ex
stikkontakt
EH1871
4004.36
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure
Fire / gas
Gas
Other
ESD battery 1Systems
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA
Telephone
GA
Utilities:
Lifting capacity offshore cranes:
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other
West Venture
Utility stasjon inngang boligkvarter 4 etg. ( 6 )
Electrical:
Tabell utvides med antall linjer etter behov
Instrument:
Telecom:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Stikkontakt. Area
*
Tavle/
utgang
(V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr Modul
No/Room
No
Main
EH1871
2003+2I
400 50 3 S 32 Rekkeklemme
Legrand
3/32A
EH1871
2003.21.
X13.01
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure
Fire / gas
Gas
Other
ESD battery 1Systems
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA
Telephone
GA
Utilities:
Lifting capacity offshore cranes:
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other
West Venture
Utility stasjon bb boxdrager. ( 7 )
Electrical: Tabell utvides med antall linjer etter behov
Instrument:
Telecom:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Cabinet Area
*
Tavle/
utgang
(V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr
Modul
No/Room
No
Main
EH1871
2003+02I
400 50 S 63 Rekkeklemme JB18710017
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure
Fire / gas
Gas
Other
ESD battery 1Systems
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA
Telephone
GA
Utilities:
Lifting capacity offshore cranes:
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other
West Venture
Utility stasjon ROV. ( 8 )
Electrical: Tabell utvides med antall linjer etter behov
Instrument:
Telecom:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Cabinet. Area
*
Tavle/
utgang
(V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr Modul
No/Room
No
Main
EN1871
4011
+01C
690 50 3 I 63 Rekkeklemme JB13710018
Main
EH1871
4006
PDB112
230 50 1 S 16 Ceag Ex
stikkontakt
EH1871
4006.07.
X1.01
EH1871
3008.08
400 50 3 32 Ceag Ex
stikkontakt
EH1871
3008.08
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure
Fire
Gas
Other
ESD battery 1Systems
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA
Telephone
GA
Utilities:
Lifting capacity offshore cranes:
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
West Venture
Utility stasjon BOP garage maindekk ( 9 )
Electrical:
Tabell utvides med antall linjer etter behov
Instrument:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Cabinet
Area
*
Tavle/
utgang
(V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr Modul
No/Room
No
Main EN1
8713011
+01E
690 50 3 No I 63 Rekkeklemme
Ceag Ex
stikkontakt
JB13210007
Main
EH13008
400 50 3 No S 63 Rekkeklemme EH13008.01
Main EH1
8710018
LTDB118
230 50 1 Yes S 16 30 Ceag Ex
stikkontakt
EH1891
0018.X4.02
Alternator
Dist.panel
440 60 3 No S 63 Rekkeklemme JB13710100
EH 87
3006.181
xx.01
?
EH 87
3006.181
xx.02
?
EH 87
3006.181
xx.03
Ceag Ex
stikkontakt
EH 87
3006.181
xx.04
Ceag Ex
stikkontakt
ECS A 2 16 STAHL Ex
stikkontakt
ECS B 2 16 STAHL Ex
stikkontakt
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure
Fire
Gas
Other
ESD battery 1Systems
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Telecom:
Utilities:
Lifting capacity offshore cranes:
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA
Telephone
GA
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other
West Venture
Utility stasjon ved riser handling crane stb. ( 10 )
Electrical: Tabell utvides med antall linjer etter behov
Instrument:
Telecom:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Cabinet Area
* (V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr Modul
No/Room
No
Alternator
Dist.panel
440 60 3 63 Rekkeklemme JB73770020
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure
Fire / gas
Gas
Other
ESD battery 7Systems
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA
Telephone
GA
Utilities:
Lifting capacity offshore cranes:
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other
West Venture
Utility stasjon Løe tak. ( 11 )
Electrical:
Tabell utvides med antall linjer etter behov
Instrument:
Telecom:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Cabinet Area
* (V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr Modul
No/Room
No
Alternator
Dist.
Panel
440 60 3 S 63 Rekkeklemme JB7377
0010X
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure
Fire / gas
Gas
Other
ESD battery 7Systems
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA
Telephone
GA
Utilities:
Lifting capacity offshore cranes:
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other
West Venture
Utility stasjon BOP garage maindekk ( 12 )
Electrical:
Tabell utvides med antall linjer etter behov
Instrument:
Telecom:
Power Volt Freq Phase
Curr
Neut.
Loaded
System
earth
Short circuit
level
Distribution
protection
Connection
platform
Cabinet
Area
*
Tavle/
utgang
(V) (Hz) (Hz) Yes/No (S/I/R)
**
Min
(kA)
Max
(kA)
Fuse
(A)
Earth
Fault
(mA)
Description/
Type
Tag nr Modul
No/Room
No
EN1871
4011
+01C
690 50 3 No I 63 STAHL Ex
stikkontakt
EN18714011
+01C
EH1871
3008.08
400 50 3 32 Ceag Ex
stikkontakt
EH1871
3008.08
EH
890018.x
4.02
230 50 2 Ceag Ex
stikkontakt
EH
890018.x4.0
2
* **
Main – Main Power S = Solidly (direkte jordet)
Emg – Emergency Power I = Isolated (isolert)
Ess – Essential Power R = Resistor (resistansjordet)
UPS – UPS Power
Function Signal type Connection
Platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/Room No
Loss of pressure
Fire
Gas
Other
ESD battery 1Systems
Function Signal type Connection
platform
Connection temp.
Equip.
Area
Description/Type Description/Type Modul No/
Room No
PA
Telephone
GA
Utilities:
Lifting capacity offshore cranes:
Crane 1m
Significant wavehight
Max.load/max.radius
2m
Significant wavehight
Max.load/max.radius
3m
Significant wavehight
Max.load/max.radius
Function Pressure Amount/flow Connection Area
(bar) Max. capac. Type Diameter Material Modul No/
Room No
Plant air
Instr.air
Sprinkler
Seawater
Freshwater
Drain
Other