Technical Manual
Wellsite Gas Watch™
Wireless Portable Monitor 1000
REFERENCE REFERENCE DESCRIPTION
This document contains proprietary and confidential information whichbelongs to Varco, LP; it is loaned for limited purposes only and remainsthe property of Varco, LP. Reproduction, in whole or in part; or use of thisdesign or distribution of this information to others is not permitted withoutthe express written consent of Varco, LP. This document is to be returnedto Varco, LP upon request and in any event upon completion of the usefor which it was loaned.© Varco, LP
M/D Totco
1200 Cypress creek Road
Cedar Park, Texas 78613
USA
Phone 512-340-5000
Fax 512-340-5219
DOCUMENT NUMBER
42TM50-25
REV
A
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
2/50
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
3/50
Document number 42TM50-25
Revision A
Page 1 of 48
www.nov.com/mdtotco
Revision History
Change Description
A 03.31.2006 Issued for Implementation
Rev Date Reason for issue Prepared Checked Approved
Revision Change Description
A First Issue
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
4/50
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
5/50
Table of Contents
Document number 42TM50-25
Revision A
Page 3 of 48
www.nov.com/mdtotco
Chapter 1: General InformationConventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Notes, Cautions, and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Safety Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Personnel Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Recommended Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6General System Safety Practices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Replacing Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Proper Use of Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Chapter 2: Set Up
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Well Information Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Packing and Unpacking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Case 1, Trap Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Case 2, Sensor Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Case 3, Laptop Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Rig Up Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Wellsite Trailer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Rig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Trap Set Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Drying System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Wireless Gas Monitor Seasonal Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 22LED Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
WITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23M/D Totco – RigSense/Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Interfacing to the Electronic Drilling Recorder . . . . . . . . . . . . . . . . . . . . . . . . . 25RigSense Rig Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Setting Up Well Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Chapter 3: OperationsKey Laptop Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Time Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Depth Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34LAS/ASCII File Creation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Shut Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
6/50
Table of Contents
Document number 42TM50-25
Revision A
Page 4 of 48
www.nov.com/mdtotco
Chapter 4: Maintenance and TroubleshootingDaily Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Gas Sample Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42No Depth or ROP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42No Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42No Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Helpful Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Lag Rate Determination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44M/D Totco Drilling Recorder Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Chimo Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
7/50
Document number 42TM50-25
Revision A
Page 5 of 48
www.nov.com/mdtotco
1: General Information
This manual contains installation, operation, maintenance and parts information. Informationin this manual should enable qualified personnel to install, operate and troubleshoot thissystem. Every effort has been made to ensure the accuracy of the information contained
herein. M/D Totco, a National Oilwell Varco company, will not be held liable for errors in thismaterial, or for consequences arising from misuse of this material.
Conventions
Notes, Cautions, and Warnings
Notes, cautions, and warnings provide readers with additional information and advise the
reader to take specific action to protect personnel from potential injury or lethal conditions.They may also inform the reader of actions necessary to prevent equipment damage. Please
pay close attention to these advisories
Illustrations
Illustrations (figures) provide a graphical representation of equipment components or screen
snapshots for use in identifying parts or establishing nomenclature, and may or may not bedrawn to scale.
For component information specific to your application, see the technical drawings included
with your M/D Totco documentation.
Note: The note symbol indicates that additional information is provided aboutthe current topics.
Caution: The caution symbol indicates that potential damage to equipment orinjury to personnel exists. Follow instructions explicitly. Extreme care
should be taken when performing operations or procedures preceded bythis caution symbol.
Warning: The warning symbol indicates a definite risk of equipment damage
or danger to personnel. Failure to observe and follow proper
procedures could result in serious or fatal injury to personnel,
significant property loss, o r si gnificant equipment damage.
ESD
Warning:
The ESD (Electrostatic Discharge) warning symbol indicates that
static control precautions are needed.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
8/50
Document number 42TM50-25
Revision A
Page 6 of 48
1: General Information
8
www.nov.com/mdtotco
Safety Requirements
M/D Totco equipment is installed and operated in a controlled drilling rig environment involving
hazardous situations. Proper maintenance is important for safe and reliable operation.Procedures outlined in M/D Totco manuals are the recommended methods of performing
operations and maintenance.
Personnel Training
All personnel performing installation, operations, repair, or maintenance procedures on theequipment, or those in the vicinity of the equipment, should be trained on rig safety, tool
operation, and maintenance to ensure their safety.
Recommended Tools
Service operations may require the use of tools designed specifically for the purpose
described. M/D Totco recommends that only those tools specified be used when stated.Ensure that personnel and equipment safety are not jeopardized when following service
procedures or using tools not specifically recommended by M/D Totco.
General System Safety Practices
The equipment discussed in this manual may require or contain one or more utilities, such aselectrical, hydraulic, pneumatic, or cooling water.
Isolate energy sources before beginning work.
Avoid performing maintenance or repairs while the equipment is in operation.
Wear proper protective equipment during equipment installation, maintenance, or repair.
Replacing Components
Verify that all components (such as cables, hoses, etc.) are tagged and labeled duringassembly and disassembly of equipment to ensure correct installment.
Replace failed or damaged components with genuine M/D Totco parts. Failure to do socould result in equipment damage or injury to personnel.
To avoid injury to personnel or equipment damage, carefully observe requirementsoutlined in this section.
Personnel should wear protective gear during installation, maintenance, and certain
operations.
Read and follow the guidelines below before installing equipment or performing
maintenance to avoid endangering exposed persons or damaging equipment.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
9/50
Document number 42TM50-25
Revision A
Page 7 of 48
1: General Information
www.nov.com/mdtotco
Routine Maintenance
Equipment must be maintained on a routine basis. See the service manual for maintenancerecommendations.
Proper Use of Equipment
M/D Totco equipment is designed for specific functions and applications, and should be usedonly for its intended purpose.
Failure to conduct routine maintenance could result in equipment damage or injury topersonnel.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
10/50
Document number 42TM50-25
Revision A
Page 8 of 48
1: General Information
8
www.nov.com/mdtotco
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
11/50
Document number 42TM50-25
Revision A
Page 9 of 48
www.nov.com/mdtotco
2: Set Up
Introduction
The M/D Totco Wellsite Gas Watch™ MC3 wireless portable gas monitor is a valuable tool forthe evaluation of hydrocarbon gases liberated, produced, and recycled while drilling. The
system has been engineered to keep maintenance to a minimum while continuously providingaccurate, repeatable and consistent data over long periods of use.
The new patent-pending sensor technology is more stable than those currently on the market
and the laptop indications provide more powerful and responsive computing possibilities.
The goal of M/D Totco is to provide reliable geological equipment and unparalleled 24-hourservice. All equipment is thoroughly examined and tested by qualified personnel to minimize
the possibility of failure in the field.Each gas monitor and its peripheral equipment are packaged in three industrial strength casesto ensure the equipment gets to the site in one piece as well as provide ease of handling in thefield.
The Wellsite Gas Watch has been designed to detect gas to surface readings for the geologist,engineer and driller. It has both repeatability and accuracy if properly maintained. For the the
most reliable and accurate data, follow the methods and use the hints and tips provided in thismanual.
The Wellsite Gas Watch provides:
State of the art infra-red sensor technology.
Three Curve Data (Methane, Propane, and Total Gas). Real-Time Log of the well including ROP and gas values.
Depth Log of the entire well (if printer requested).
LAS transfer capabilities to various strip logs.
The ability to write comments to the time log.
Extensive alarm suite.
Large display screen for easy viewing.
Note: Remember that your data is dependent on the ability of gas flow to the sensor.
Ensure that flow is unrestricted.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
12/50
Document number 42TM50-25
Revision A
Page 10 of 48
2: Set Up
30
www.nov.com/mdtotco
Information
It is important for M/D Totco to be supplied information pertaining to the job you are going to as
well as the information after each well is complete.
Before picking up a gas monitor please provide:
Company Name: __________________________________________________________________
Well Name: _______________________________________________________________________
LSD: _____________________________________________________________________________
Billing Contact: ___________________________________________________________________
AFE: _____________________________________________________________________________
Rig #: ____________________________________________________________________________
Rig Directions:
__________________________________________________________________________________
__________________________________________________________________________________
__________________________________________________________________________________
__________________________________________________________________________________
__________________________________________________________________________________
__________________________________________________________________________________
__________________________________________________________________________________
Phone Number - Geologist (Field): _______________________________________________
Phone Number - Geologist (In town): _____________________________________________
Which electronic drilling recorder: _______________________________________________
Are you air drilling? _____________________________________________________________
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
13/50
Document number 42TM50-25
Revision A
Page 11 of 48
2: Set Up
www.nov.com/mdtotco
Well Information Sheet
At the end of each month, please submit all well information via e-mail [email protected] or fax to 1-403-230-0672
Standby charges may apply between wells
Please be prompt when returning equipment
Please have all well information at time of pick-up for your next well
If you have any questions or concerns please call 1-877-316-0630
Comments:
Make copies of this page and fill this form out after each well.
Pick Up Date: _______________________________
mm/dd/yy
Drop Off Date: ________________________________
mm/dd/yy
Start Date: _________________________________
mm/dd/yy
End Date: ____________________________________
mm/dd/yy
Geologist: __________________________________ Phone Number: _______________________________
Geological Consulting Company: ______________________________________________________________
Geologist E-mail Address: ____________________________________________________________________
Oil Company: _______________________________________________________________________________
Client Contact: _______________________________ Phone Number: _______________________________
Well Name: _________________________________________________________________________________
LSD: ________________________________________ Rig Number: __________________________________
AFE Number: _______________________________________________________________________________
Gear at Rig: Yes_____ No____ Gear Returned: Yes_____ No____
Partial Gear Returned: Yes_____ No____Items Returned: _______________________________
______________________________________________
Next Location:M/D Totco Rep.:______________________(In/Out)
Initials
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
14/50
Document number 42TM50-25
Revision A
Page 12 of 48
2: Set Up
30
www.nov.com/mdtotco
Packing and Unpacking
M/D Totco provides three hard shell cases that contain the instruments and the equipment
needed to set up the gas monitor.
Please return the equipment in the proper cases and wash the trap assembly as the rig.
Note: Depending on the type of setup you will require different hardware.
Caution: Do not plug in the laptop or sensor assembly if it has been in a below
freezing environment. Let it warm to room temperature before applying power.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
15/50
Document number 42TM50-25
Revision A
Page 13 of 48
2: Set Up
www.nov.com/mdtotco
Case 1, Trap Case
Contents of the trap case are:
1 – Gas Trap (Mud Agitator)
1 – Shaker Box Crank Bracket
1 – Glycol Assembly
4 – ½" plastic nuts for jar connection
1 – Rubber hose and cam lock
2 – Short ½" hose for jar connection
The trap case contains the gas trap, the T-stand, and the crank. The trap case is packed in a
specific order. If this is not followed, the gear may not fit into the case.
1. Place the trap on the bottom and to the back of the case.
2. The crank is made as compact as possible and placed toward the front side of the case.
3. The T-stand is placed on top of the crank, tucking it in the case as low as possible.
Do not forget to include the rubber hose with camlocks, 2 1/2" x 12" poly-flow lines, andextra 1/2" plastic nuts for securing poly to T-stand.
4. Slowly close the case while watching for anything that does not fit properly, or may be
pinched by closing the case.
If the case does not close
properly, do not force it to
close. Check all the parts
and adjust them as
necessary.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
16/50
Document number 42TM50-25
Revision A
Page 14 of 48
2: Set Up
30
www.nov.com/mdtotco
Case 2, Sensor Case
Contents of the sensor case are:
1 – Accessory Kit
1 –Wireless Portable Gas Monitor
1 – Extension power cord
The sensor case contains the wireless gas monitor, the accessory kit, and the trap extension
cord. The specific order for packing a sensor case is:
1. Place the trap extension cord in the bottom of the case. (As shown below).
2. Put the wireless unit on top of the trap extension cord.
The monitor antenna must face the front of the case, and the monitor must face up. This
ensures the unit does not move around too much during shipping, and prevents the
antenna from damage.
3. Finally, place the accessory kit in the case, on top of the other equipment. Close thecase and set it aside while packing the laptop case.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
17/50
Document number 42TM50-25
Revision A
Page 15 of 48
2: Set Up
www.nov.com/mdtotco
Case 3, Laptop Case
The contents of the laptop case do not need to be packed in any specific order.
Laptop and power supply
Manual
Serial laptop to interface box cable (9-pin male to 9-pin female)
Mouse and pad
Box of disks
Surge protector
Wireless radio (black box) with antenna and power adapter
WITS communication box (Pason or combo box)
USB to 9-pin serial cable
25 to 9-pin connector
Null Cable (9-pin female to 9-pin female, used for Pason or other)
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
18/50
Document number 42TM50-25
Revision A
Page 16 of 48
2: Set Up
30
www.nov.com/mdtotco
Rig Up Procedure
Wellsite Trailer
1. When arriving on site, place the laptop case in the shack and remove the equipment.
Allow it to warm to room temperature if it has been in a below freezing environment.
2. Remove the laptop, surge protector, and wireless radio (black box) and set them on the
work area.
3. Attach the wireless radio (black box) to the laptop (rear 9-pin COM port or USB to 9-pinlabeled Sensor/Radio) using the 9-pin to 9-pin cable provided.
4. Screw in the antenna and plug in the power adapter for the wireless radio.
5. Screw in the 9-pin screws to ensure a good, tight connection.
6. Plug the mouse into the laptop.
7. Plug in the laptop computer to the surge protector, the laptop is equipped with its ownback-up battery and power supply.
8. Plug the surge protector into a wall socket and turn on the power to the surge protector.
Also, plug in any USB to 9-pin cables before turning on the laptop.
9. Turn on the laptop. The Wellsite Gas Watch program will start automatically.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
19/50
Document number 42TM50-25
Revision A
Page 17 of 48
2: Set Up
www.nov.com/mdtotco
Rig
Trap Set Up
1. Remove the trap assembly from trap case and hang it on the shaker box using the crank
provided.
It is a good idea to inform the rig personnel about the trap level just in case they close or
open the baffles on the shaker. It is also good practice to keep the trap at a consistentlevel throughout the well. Place the trap bracket and trap assembly such that when therig is making a connection, the mud level will drop below the bottom of the trap canister
by approximately 1/4" to 1/2". As the rig starts the mud pumps, the mud level willincrease and the canister will become submerged to the appropriate level
(approximately 2 to 3 inches). When the trap is installed correctly, the flow of the exitmud will be very brisk.
2. Be sure to place the trap in an area of high flow such as directly in front of a flow line. Do
not put it in the corner of the shaker because there can be a build up of debris in this
area which will plug the bottom of the trap and affect the gas readings.
3. Attach the glycol and dryer assembly (Figure 2.1 on page 18). Then slide the hose
coupler onto the trap standpipe and lock it by pulling the handles up. Pour a smallamount of glycol into the large bubble jar, about 2 inches. Do not over fill, you may
Caution: Do not lower the trap too deep or mud will be drawn through the line tothe sensor assembly and a service call will be required.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
20/50
Document number 42TM50-25
Revision A
Page 18 of 48
2: Set Up
30
www.nov.com/mdtotco
suck up fluid. Prepare the calcium chloride dryer by pouring 2-3 inches of calciumchloride into the small jar. The glycol should bubble when the gas monitor is running and
sucking the gas sample through.
Figure 2.1: Jar Set Up
Note: In winter conditions, it may be necessary to dilute the ethylene glycol with water
(no less than a 60/40 mix) to keep it from freezing in the bubble jar.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
21/50
Document number 42TM50-25
Revision A
Page 19 of 48
2: Set Up
www.nov.com/mdtotco
Drying System
1. The T-bar drying system consists of a long glycol jar and a short Ca Cl (calciumchloride) jar. The lids are attached by eye hooks and swing freely. The jars contents are
simply changed by unscrewing them from the lids. The jars are clearly labeled for
content as well as height measurement. The whole system is light and portable. Thehollow T-bar slides over the top of the mounting pin located on top of the gas trapmaking it convenient for maintenance.
2. The large inlet hose ascending from the standpipe, located on the canister, connects to
the plastic inlet fitting on the glycol jar. On the other side of the glycol jar lid is a smallcompression fitting. From that fitting, a short piece of 3/8” poly needs to be in place to
connect the compression fitting located on the Ca Cl jar lid. The last compression fittingon the Ca Cl jar is for the 1/4" poly-flow going to the gas monitor.
Note: For invert mud system, replace calcium with nylon batting.
Warning: Do not remove poly-flow line from T-stand before removing it from the
trap.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
22/50
Document number 42TM50-25
Revision A
Page 20 of 48
2: Set Up
30
www.nov.com/mdtotco
3. Hang the Wellsite Gas Watch unit over the handrail of the mud tanks close to the trap.Make sure the switches are in the off position (right to left). Connect the left electrical
NRL plug on the gas monitor to the trap power NRL plug.
4. Connect the extension power cord to the right NRL plug and run it to the utility shack orany available 115 VAC power plug.
5. Once the entire unit is connected, turn the breaker power on at the power source.
6. Turn the two toggle switches on at the bottom of the wireless detector. The LED light willlight up through the glass window, and then the signal will lock onto the radio in the
shack. The processor LED will blink and the TX (transmit) LED will flash twice each timethe wireless sensor transmits (every 2 seconds).
7. Attach a coiled piece of poly-flow line to the small fitting on the side of the glycol jar (Theother end will go to the Wellsite Gas Watch unit IN port on the top left hand side of theenclosure).
8. Insert poly line in the bottom of the in-line filter and use tie wraps (from the accessorykit) or tape to secure the poly in place.
Note: Be sure to use the in-line air filter.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
23/50
Document number 42TM50-25
Revision A
Page 21 of 48
2: Set Up
www.nov.com/mdtotco
Please read the helpful information section for more tips on the sampling system.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
24/50
Document number 42TM50-25
Revision A
Page 22 of 48
2: Set Up
30
www.nov.com/mdtotco
Wireless Gas Monitor Seasonal Operation
For winter operations, a winter hood is provided to help shield the unit from wind and snow aswell as help to keep the unit clean. To install the hood, place the hood over top of the unit andsecure the velcro flaps on each side of the hood.
The flap on the side of the gas monitor is to change the in-line filter. The flap on the front of thegas monitor is to view the LED plate.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
25/50
Document number 42TM50-25
Revision A
Page 23 of 48
2: Set Up
www.nov.com/mdtotco
LED Plate
Processor: Flashs quickly for the first minute while the unit is energizing. Onceenergized, the flash will be slow and steady. If the red LED stays solid, then shut down
the sensor and turn it back on.
Sensor Packet: The sensor that transmits to the main board.
RX: Stays illuminated when it connects to the radio in the geologist shack. It will remain
off when there is no connection.
TX: Illuminates when the WGM transmits from the main board to the radio in the
geologist shack.
RSSI: Signal strength; full strength is indicated by full bars (3 LEDs illuminated), theLED will cycle until it can connect to the radio.
WITS
Wellsite Gas Watch is able to receive and transmit data through a well information transferspecifications (WITS) protocol. This protocol provides the necessary information to the
computer for the operation of various electronic drilling recorders.
WITS supplies the depth, rop, and circulation indicators as well as on/off bottom indicators tothe computer system.
Codes received are:
0108 – Bit depth
0110 – Hole depth
0113 – Rate of penetration
0123 – Pump 1
0124 – Pump 2
0125 – Pump 3
Off bottom is indicated by a bit depth of .5m less than the hole depth.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
26/50
Document number 42TM50-25
Revision A
Page 24 of 48
2: Set Up
30
www.nov.com/mdtotco
Codes sent are:
0139 – Lagged depth
0140 – Total gas
1212 – Methane 1214 – Propane
In order to receive WITS communication, a connection must be made to the drilling recorder.This is accomplished one of two ways:
1. Through a 6 ft. null modem cable (9-9 pin female to female) between the Wellsite Gas
Watch laptop and the drilling recorder workstation in the shack.
2. Directly to the electronic drilling recorder at the tool pusher’s shack using the 250 ft.cable and the black communication interface box provided (the one with the Chimo /
Other switch on the side not the radio).
Chimo, Pason, M/D Totco, Fleet Coil, and Ryan are some of the service companies currently
sending and receiving WITS protocol.
M/D Totco – RigSense/Iris
Hardware:
(1) 9-pin female to 25-pin male adapter (located in the laptop case)
or
(1) Communication box and adapter
(1) Combination communication cable 250'
Wellsite Gas Watch has implemented a combination M/D Totco (Chimo) / Pason cable andcommunication box that is designed for both types of electronic drilling recorders. Connect the
combination cable to the EDR (M/D Totco 4-pin / Pason 6-pin) and attach the other end of thecable to the supplied combination box. Then use the switch on the box to choose the type of
EDR being used.
The M/D Totco electronic dril ling recorder requires that the supplied communication cable(Wellsite 4 pin) be connected to the serial card on either the left or right hand side of the
M/D Totco (Chimo) Setup Pason Setup
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
27/50
Document number 42TM50-25
Revision A
Page 25 of 48
2: Set Up
www.nov.com/mdtotco
Wellsite laptop using the 25-pin and 9-pin connectors and the cable provided. The M/D Totcosystem uses WITS protocol and will send the necessary drilling information to the gas monitor.
The depth is displayed automatically on the Wellsite program shortly after a new well is started
and Start Log is selected from the File menu. The gas detector will display WITS ON.
If the hardware connection is made but a WITS signal is not recieved, the laptop displays
WITS NO LINK.
For help with communication problems between Wellsite Gas Watch and RigSense (IRIS),
refer to "Helpful Information" on page 44.
Interfacing to the Electronic Drilling Recorder
Interfacing to the M/D Totco (Chimo) EDR
1. Ensure toggle switch is on Chimo.
2. Using the 9-pin to 25-pin serial cables provided in the portable gas logger case, attach
the 9-pin end to WITS port on the portable gas logger and 25-pin end to the 25-pinfemale port on the interface box.
3. Using the dual interface cable provided, attach the single 4-pin end to the universal
interface box. Using the dual pigtail end, attach it to any available Chimo Workstationwith a 4-pin Amphenol connector attached to COM 3.
4. If all hardware is good and is hooked in correctly, both lights in the interface box windowwill be illuminated red.
Note: At this point, the universal interface box should be plugged into an outletseperate from the UPS that powers the portable gas logger and laptop.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
28/50
Document number 42TM50-25
Revision A
Page 26 of 48
2: Set Up
30
www.nov.com/mdtotco
Interfacing to the Pason EDR
1. Ensure toggle switch is on either Pason or Other.
2. Using the 9-pin to 25-pin serial cables provided in the portable gas logger case, attach
the 9-pin end to WITS port on the portable gas logger and 25-pin end to the 25-pinfemale port on the interface box.
3. Using the dual interface cable provided, attached the single 4-pin end to the universalinterface box. Connect the dual 6-pin end to the back of the tool pusher trailer in anavailable WITS port that is properly configured to send WITS.
4. If all hardware is connected correctly, the interface box will have two red lights.
RigSense Rig Up
1. To connect the Wellsite Gas Watch unit to the RigSense 2.0 system, use a 9-pin male tomale NULL modem cable.
2. Connect one end of the NULL Modem cable to the DB 9-pin connector, COM 1 on the
Dell client / workstation computer.
3. Connect the other end of the NULL Modem cable to the DB 9-pin connector, COM 2 on
the Wellsite Gas Watch laptop.
4. On the clients computer, click the Setup button.
5. Click the WITS Setup button.
6. Click the COM Port button and select 1 for COM 1 (if not already selected).
7. Click the WITS Output Channels button and select the following channels for output tothe PGL:
Bit Position
Bit ROP
HoleDepth
Pump SPM 1
Pump SPM 2
Pump SPM 3, if the rig has a 3rd pump.
Note: At this point, the universal interface box should be plugged into an outletseperate from the UPS that powers the portable gas logger and laptop.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
29/50
Document number 42TM50-25
Revision A
Page 27 of 48
2: Set Up
www.nov.com/mdtotco
8. Click the WITS Input Channels button and select the following channels for input toRigSense:
Lag Depth
Total Gas
Methane and propane gas (optional)
9. Click on the Exit button to leave the WITS Setup screen.
10. If a WITS signal is not being received on the Wellsite Gas Watch unit in about oneminute, press the Alt & F4 keys on the RigSense 2.0 client. This will cause RigSense toshut down and automatically restart on the client computer. On to the Setup > WITS/
Pulse > WITS Setup screen, the status displayed should show that WITS is Running.
11. If a WITS signal is still not being received on the Wellsite Gas Watch unit, reboot the
Wellsite Gas Watch laptop.12. If necessary reboot client.
13. If necessary restart RigSense on the AppSvr.
Setting Up Well Information
Now that the hardware and sample lines are installed, it is time to enter the well data and startlogging the well.
If you have not yet done so:
1. Turn on the surge protector.
2. Turn on the laptop.
The laptop automatically opens the Wellsite Gas Watch program.
Note: The above input channels must be checked only on one RigSense client
computer, the computer that is connected to the WellSite Gas Watch unit.
Note: the above two steps are not necessary if RigSEnse version 2.0, SP4 isinstalled.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
30/50
Document number 42TM50-25
Revision A
Page 28 of 48
2: Set Up
30
www.nov.com/mdtotco
The system is not logging data until a file is created and Start Logging is selected.
The Track title bar is red until logging is started and a data file is created. When a well file is
created and logging begins the Track title bar turns green and a WITS signal is sent andreceived.
To open an existing file:
1. From the Wellsite Gas Watch tool bar choose File > Open and locate the file.
2. It is placed in the E:\Data files folder.
3. Enter your password.
Be sure to choose Start Logging after the file is opened and recheck the parameters(Lag Rate, Pump Delay, Methane and Propane).
To Start a New Well File:
1. Select File
2. Select New
Depth of gasCurrent depth
Main menu
Track title bar Header data
@ surface
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
31/50
Document number 42TM50-25
Revision A
Page 29 of 48
2: Set Up
www.nov.com/mdtotco
3. Enter the necessary well data.
4. The new well will be saved with the file name entered on the Save As dialog.
5. A password is needed to access a saved well. Click once on Save.
6. The Wellsite Gas Watch Setup screen is displayed.
7. Enter the Annular Velocity for the well. This is the annular velocity of the gas sample.Detailed information for this calculation is included in "Helpful Information" on page 44.The rig engineer is also a source for this information.
8. Enter the pump delay. This is the amount of time it takes for the sample to travel from
the trap assembly to the gas sensor.
With a wireless detector present, enter 5 seconds for ten feet of poly.
Note: Save the file in the E:\datafiles folder.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
32/50
Document number 42TM50-25
Revision A
Page 30 of 48
2: Set Up
30
www.nov.com/mdtotco
9. The Circulation is determined by the presence of either a pump pressure switch(geolograph type setup) or the WITS signal supplied by other service companies. Auto
is controlled automatically by the sensors on the rig. There is also a manual on and offsetting for special situations where neither WITS nor pump pressure is available (i.e.: air
drilling).
10. The Depth / WITS is used to indicate the depth on the gas monitor by way of either thedepth encoder assembly or the WITS signal supplied by other service companies. If
WITS is present, the depth will be displayed automatically after you choose Start Log from the File menu.
11. Enter the gas curve to print.
12. The Displayed Gases selection allows methane and propane gases to be displayed onthe screen; TG is displayed by default.
13. Drilling Thresholds are the distances that define off bottom and on bottom while
drilling. If you have a rig with tighter tolerances, the values can be changed here.
Note: Gas indication is units or percent; gas scale is linerar or arithmetic.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
33/50
Document number 42TM50-25
Revision A
Page 31 of 48
www.nov.com/mdtotco
3: Operation
Key Laptop Functions
Time Log
The time log provided by Wellsite Gas Watch™ is a continuous real-time log that provides gas
readings, and rig functions on hard copy as well as on the laptop display and hard drive.
The real-time information on the laptop is actual and cannot be edited. This log can be viewedand reprinted after adding comments.
To Print a Real-Time Log
When the Wellsite Gas Watch program is open, choose Print > Real-Time Log Headings,then Print Real-Time Log, this will print your headings a line of data every minute thereafter. If
Note: M/D Totco does not provide a printer unless it is specifically requested by the
client!
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
34/50
Document number 42TM50-25
Revision A
Page 32 of 48
3: Operation
40
www.nov.com/mdtotco
it does not print, check all connections and make sure Real-time Log is checked under theprint tab on the main tool bar.
To Print a Section of a Time Log
1. Click the Print tab on the main tool bar.2. Click Time Log.
3. Enter the Start and Stop Date and time.
4. Click OK.
5. Select to print 1, 2, 5, 10, or 30 minutes per line. This is useful for very slow drilling wells.
This will print the selected time log section.
After the printing is finished, the gas detector will print the information that has beenaccumulated during the printing process.
To cancel a print job, double click on the printer icon in the lower right corner of the laptop,choose the job you want to cancel (e.g.: right click Time Log and then select Delete on themenu). The printer will continue with the information in the buffer and then print the data
missed while printing.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
35/50
Document number 42TM50-25
Revision A
Page 33 of 48
3: Operation
www.nov.com/mdtotco
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
36/50
Document number 42TM50-25
Revision A
Page 34 of 48
3: Operation
40
www.nov.com/mdtotco
Depth Log
The Wellsite Gas Watch Depth Log provides a printout of depth with respect to the lagged gasvalues. If the lag rate was correct throughout the well, the higher gas values will correspond to
the faster ROP zones. The effect of this will be a visual cross over of the ROP and gas. It isbest to print this log in logarithmic scale, although linear is also available.
To print a depth log:
1. Click the Print tab on the main tool bar.
2. Select Depth Log.
3. Enter the Start and End Depths.
4. Select OK.
This will print the selected depth log.
To cancel a depth log print job:1. Double click on the printer icon in the right hand corner of the computer screen.
2. Select a job listed.
3. Right click the selection and select delete on the pop-up menu.
After clearing the buffer, the printer will continue with the real-time data in the buffer
while depth log was being printed.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
37/50
Document number 42TM50-25
Revision A
Page 35 of 48
3: Operation
www.nov.com/mdtotco
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
38/50
Document number 42TM50-25
Revision A
Page 36 of 48
3: Operation
40
www.nov.com/mdtotco
LAS/ASCII File Creation
ASCII files are created to enable the portable gas detector information to be loaded intovarious strip logs that geologists use to present to their clients. The ASCII file is created by
using the lagged gas information. This information may also be edited for import.
To create a LAS file and send it to floppy disk:
1. Go to the LAS tab on the main tool bar.
2. Choose Create LAS.
3. Enter the Start and Stop depth for the file.
4. Choose the depth step increments for the file. These are averaged values over the depth
increments requested.
5. Choose whether to display data in percent or units.
6. Leave the Depth Correction and Scan to End of File checked. This feature will correct
for depth changes that are made while drilling.
7. Select which gases to display in the LAS file.
8. Select OK.
Example 1: If the driller makes a forward depth correction, there is no data for that intervalso null values will be displayed in the LAS file.
Example 2: If the driller makes a backward depth correction, the depth of 1,100m may be
displayed twice. The data given in the LAS file is the last (most recentoccurrence of 1,100m).
Example 3: If there is an erroneous depth (i.e. 20,000m) given over the LAS data intervalrequested, null values are displayed.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
39/50
Document number 42TM50-25
Revision A
Page 37 of 48
3: Operation
www.nov.com/mdtotco
Now that the LAS file has been created, it is available to import into the Strip Log program.
To view the LAS file you created on the Wellsite Gas Watch computer:
1. Click the Start icon in the bottom left of your laptop screen
2. Click Programs > Accessories > WordPad.
3. In WordPad click File > Open.
4. Select Look In A:\ (Floppy).
5. Under Files of Type: choose all documents and locate the ASCII file you had previously
created.
6. Double click on the desired file to open it for viewing.
7. Edit the values in WordPad and save before strip log import.
Alarms
The Wellsite Gas Watch has audible and visual alarms that can be set by the user. They arean excellent way to be alerted if there are problems on the rig or with the gas monitor so it is agood idea to use them.
To activate the alarms:
1. Enter the values for the alarms to set them.
2. Enable the alarms by selecting the appropriate alarm heading.
3. Select OK.
4. The alarms that are active will appear on the main real time screen at the bottom right.
5. Be sure to turn up the alarm volume on the laptop computer so the alarm is audible.
6. When an alarm sounds it must be acknowledged. Take corrective action on all alarms.
Note: The Wordpad file must be saved if edited.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
40/50
Document number 42TM50-25
Revision A
Page 38 of 48
3: Operation
40
www.nov.com/mdtotco
Communication alarms allow monitoring of the following:
WITS Informs when data from the EDR is not being received. This could mean the EDRis down or there is a connection problem to the EDR.
Link Informs when communication between the laptop radio and the wireless sensor
has been lost.
Sensor Indicates sensor output has failed.
Line Flow Indicates line flow transducer output has failed.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
41/50
Document number 42TM50-25
Revision A
Page 39 of 48
3: Operation
www.nov.com/mdtotco
Shut Down
When a well is completed, back-up the data files and then delete them from the laptop.
1. Back-up the data files and delete them from the laptop.
2. Close the Wellsite Gas Watch program.
3. Double click My computer on the desktop.
4. Navigate to E:\ Data Files and delete these files (.dat, .dpl, .raw).
5. Navigate to E:\ Morning Reports and delete these files.
6. Empty the files in the Recycle Bin on your desktop.
7. Remove any disks from the floppy drive.
8. GoTo Start (bottom left of desktop).
9. Click Shut Down.
10. Choose Shut down an click OK.
11. Pack the Wellsite Gas Watch in the cases as described in "Packing and Unpacking" onpage 12.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
42/50
Document number 42TM50-25
Revision A
Page 40 of 48
3: Operation
40
www.nov.com/mdtotco
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
43/50
Document number 42TM50-25
Revision A
Page 41 of 48
www.nov.com/mdtotco
4: Maintenance and Troubleshooting
Daily Maintenance
Now that the gas monitor has been set up, there are some daily maintenance procedures thatmust be followed in order to provide quality and consistent data.
Trap
The trap is a very important part of the gas detection system because it provides the sample tothe detector. It is important to place the trap in a location of high turbulence, such as in front of
the flow line in the shaker box. This will lessen the chance of shale build up under the trap andexpose the beater bars to drilling mud gas that represents what is coming up hole.
Try to keep the trap at a consistent level in the shaker box. A change in trap level can affect thegas readings. Inform the rig crew not to close the baffles or increase the shaker level without
notifying you. A submersed trap may cause fluid to be drawn into the flow line to the sensor;which will require a service call. It is important to check the dryer assembly and sample pipe inthe plastic trap mold to ensure it is not plugged or frozen! Pouring hot water down the trap
mold or using the wash gun at the rig can ensure there is an unobstructed gas sample gettingto the gas detector.
During the winter, place the hood provided over the trap. This will keep the trap motor heat
inside the sack, preventing the trap from freezing in extreme cold conditions. See "Wireless
Gas Monitor Seasonal Operation" on page 22 for details.
If the trap is submerged it should not suck up fluid, but if laid down to clean the shale shaker
the glycol will get sucked into the wireless unit. Please be careful to prevent a service call.
Sensor
The gas sensor requires little maintenance to ensure there is a clean, dry gas flow. Ensure thatthere is no fluid reaching the sensor by properly maintaining the trap and dryer assembly.
Testing and use has shown that it is not necessary to zero the gas monitor. To check the zero,
simply remove the incoming sample line to the wireless detector. It should come close to 20units. A baseline set to zero and gas will be indicated on top of the zero baseline.
The integrity of the sensor can be tested by using the lighter provided from the accessory kit.
First, release gas from the lighter into the gas in-line intake of the wireless detector (you mustbe logging to see a response). The response will vary depending on the condition and type oflighter used, but a response of 1-3% propane is acceptable for a 1-minute test.
It is a good idea to perform a gas test at the trap from time to time. Use the butane lighterprovided to release the gas into the sample line at the calcium chloride dryer. Do not light thelighter at the shaker box, only release the butane gas at the sensor. Re-attach the sample
Note: Above all, do not allow fluid to be drawn into the sensor housing. If this happens
call the local service representative.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
44/50
Document number 42TM50-25
Revision A
Page 42 of 48
4: Maintenance and Troubleshooting
48
www.nov.com/mdtotco
line and look at the log on the laptop or the real time print to see the lighter response. Theresponse should be 1-3% propane for a one minute gas test.
Gas Sample Lines
Use common sense when running the poly-flow and electrical lines across the mud tanks toensure they do not get damaged by rig crew operations. Periodically check the flow lines forkinks, holes, and moisture. The flow lines are the conduits for proper gas readings.
Troubleshooting
No Depth or ROP
WITS set-up: (If depth is not being picked up by the Wellsite Gas Watch™ laptop).
Check to see if the electronic drilling recorder is running properly.
Make sure you have chosen File > Start Logging on the Wellsite Gas Detection tool bar
(green bar across the top).
Check the connections.
Visit the supplemental information at the back of this manual for individual electronic
drilling recorder information.
Check to make sure that the combo box is plugged in.
Check to make sure the switch on the combo box is in the right place.
No Gas
If you find you are not reading gas:
Do a butane test at the inline of the wireless portable gas monitor (be sure you are
logging). The propane response should be 1-3% for a 60 second test.
Perform a butane test at the top of the calcium dryer. (DO NOT LIGHT the lighter at theshaker.) You will get a response on the laptop of 1-3% propane.
Check the trap assembly and make sure the gas sample can freely travel through theentire trap assembly. Run some water down the standpipe in the polyurethane mold to
ensure good flow through the trap.
Check for a good seal in both the glycol and calcium chloride dryers. There should be anO-ring in each. If not, there is a spare in the accessory kit.
No FlowIf you find you have diminishing or no flow check the following:
Is the sensor box powered up?
Is the in-line air filter on the intake of the wireless gas monitor plugged up?
Is the airflow numeric indication over 900 on the laptop?
Note: M/D Totco recommends replacing the poly line every 30 days to reduce
possibility of contamination.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
45/50
Document number 42TM50-25
Revision A
Page 43 of 48
4: Maintenance and Troubleshooting
www.nov.com/mdtotco
If you remove the sample in-line does the flow increase? If it does, there is anobstruction somewhere between the trap assembly and the gas monitor.
Check the trap assembly (AC power, dryer, standpipe, connections for obstructions).
Check the polyflow sample in line, (kinked, damaged, moisture, freezing).
Under the Help menu in the top task bar you will find the Debug Screen, this screen can assistyou on verifying if you are receiving WITS or data from the Wellsite Gas Watch unit.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
46/50
Document number 42TM50-25
Revision A
Page 44 of 48
4: Maintenance and Troubleshooting
48
www.nov.com/mdtotco
Helpful Information
Lag Rate Determination
The Wellsite Gas Watch will take the lag rate you enter (annular velocity) and increase the
amount of time of the gas to surface with increasing depth. If the pump strokes are increasedor the pump output changes, the lag rate will also change. It is a good idea to test or make
note of the lag rate frequently.
There are different methods that can be used to calculate the Lag Rate for a gas sample. Wewill attempt to explain a few of them:
1. Ask the engineer for the Annular Velocity. This will give you the correct value for the
current depth of the well. Enter this into the lag rate in the Setup menu.
2. Wait for a coal marker and time the gas response to surface. This will allow you to
calculate the lag time from the bit to surface.
Example: If you hit the coal when the bit is at 1800m and we see a gas response at thesurface in 47min., the gas is traveling up the annulus at a rate of 1800m / 47min. =
38.3m / min.
* Enter this 38.3m / min. into the Lag Rate cell on the laptop Setup screen
3. Perform a tracer test (actual Lag Rate).
This test is the most reliable method to determine lag time. It is done by placing a tracersuch as cut up flagging tape or whole oats in the drill pipe at the surface when the Kellyis broken off. The total time taken for the tracer to reach the surface, (shaker box) less
the time to pump the tracer to the bit is the Lag time. From the lag time we can thencalculate the rate.
M/D Totco NOV does not supply red dye pellets for tracer material.
Lag Rate (m / min.) = Depth / Time
The Lag Rate used for the Wellsite Gas Monitor is an annular velocity in m/min. that
should be determined by a tracer type test.
After timing the tracer from the drill pipe to the shaker, we must calculate the time takento pump the tracer down the drill pipe to the bit and subtract this from the total time. This
is done by calculating the downtime or the time it takes for the mud to reach the bit fromsurface.
Note: Before putting anything down the well bore, ask the Engineer or Drillier
if it is ok.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
47/50
Document number 42TM50-25
Revision A
Page 45 of 48
4: Maintenance and Troubleshooting
www.nov.com/mdtotco
4. Check mud report, quite often the lag rate will be indicated.
Example: It takes a total circulation time of 60 minutes for the tracer to show at theshaker from surface. The bit is currently at a depth of 1610m.
We need to know:
Downtime (min.) = pipe volume (m3
/ m) / pump output (m3
/ min.)
Where pipe volume (m3) = pipe capacity (m
3 /m) x length of pipe (m)
Pump output = m3 / stroke x 100 SPM = m3 / min.
Remember, the total pipe volumes will be the pipe volume + bottom hole assemblyvolume + any other piping that is in the drill string.
Say we know the total volume of the pipe is 10.33m
3
and the pump output is 1.334m
3
/min. Now:
When this value is put into the Wellsite Gas Watch unit, as the depth increases, theamount of time required for the gas to reach the surface will be increased due to
increasing depth.
Where pump output (m3 / min.) = Liner size (mm) Table needed
Stroke Length (mm) Table needed
Strokes per minute Table needed
Downtime = 10.33m3 / 1.334m
3 / min.
= 7.74 minutes
Lag time at the current depth (1610m) = Total Time - Downtime
= 60 min. - 7.74 min. = 52.56 min
Therefore the lag rate is 1610m / 52.56 min. = 30.63m / min.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
48/50
Document number 42TM50-25
Revision A
Page 46 of 48
4: Maintenance and Troubleshooting
48
www.nov.com/mdtotco
5. Calculate theoretical lag rate.
There are other formulas that can be used in order to theoretically calculate the LagRate (annular velocity). These calculations will not be accurate because of the hole
washout etc. The best determination of lag rate is done with a tracer or marker.
Time = Depth / Annular Velocity
Annular Velocity =
Annular Velocity =
Pump output m3 / min. x 1273 x 103
(Hole diameter)2 - (Pipe diameter)2
Pump output m3 / min. x 1273 x 103
(Csg ID)2 - (Pipe OD)2
For casing use:
Annular Velocity =Pump output m3 / min. x 1273 x 103
(Hole OD)2 - (Pipe OD)2
Down Time =
Where:Pipe volume = pipe capacity x length of pipe
Pipe volume m3
Pump output m3 / min.
For drill pipe use:
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
49/50
Document number 42TM50-25
Revision A
Page 47 of 48
4: Maintenance and Troubleshooting
www.nov.com/mdtotco
M/D Totco Drilling Recorder Information
A cable needs to be run from the M/D Totco computer, (usually tool pushes shack) to theportable gas monitor computer. The cable will come from the Com 3 port of the Server and
change from a 25-pin DB connector to a 4-pin amphenol connector, (100ft. cable supplied byM/D Totco), then to the Wellsite Gas Monitor computer using the 25 to 9-pin connectorprovided by Wellsite and a pigtail with lights or a small black box.
If you are hooked up to a black WITS box, you will need to plug it in. The lights in the box willturn on. One light is for sending and the other is for receiving; the lights will flash when a signalpasses through.
If you are hooked up to a pigtail with two rows of lights, once the RS232 is connected to the
Wellsite Gas Watch Monitor, you should see some lights on the bar. The red #3 light blinkingindicates that M/D Totco EDR is sending data, and the red #2 light blinking indicates that the
gas monitor is sending data.
On the M/D Totco machine that is physically connected to the Wellsite Gas Watch Monitor,select close, then setup. Type in 955-8901 for a password select enter, then select the
Sensors Installed button. ON THIS MACHINE ONLY: HAVE GEOLOGIST-MUDLOGGER andWITS (IN/OUT) CHECKED OFF. Now, select Update and choose Com 3 when asked for acom port and select Enter. Now, press the Select WITS Output button. The Wellsite Gas
Watch Monitor requires Bit Depth, Hole Depth, P1, P2, and ROP. Select Update and thenclose to go back to the drilling recorder.
Total gas will be displayed at the top of the drilling recorder and the depth and ROP will be
displayed on the gas monitor.
Chimo Troubleshooting
Question:
Total gas shows up on the drilling recorder as square lines, and if I go back in time and thenforward in time it changes. It may show the total gas dropping to zero and then coming back.
Answer:
Geologist - Mudlogger is checked off on more than one computer in sensors installed. Do not
have it checked on any other machine other than the one it is connected to.
Question:
My gas monitor was getting depth and ROP but now it is not.
Answer:
Check the M/D Totco Electronic Drilling Recorder to ensure that it is working properly. If it isworking alright then try restarting the Interface box of the logger. If this does not work, go to
the M/D Totco EDR that the portable Wellsite Gas Watch unit is plugged into and press Alt-F4until you are at a blue screen with white dots. Now click on the start button and then click onModel 3000 Drilling Recorder. It should re-initialize the Com port and start sending data again.
-
8/18/2019 Wellsite Gas Watch - Wireless Portable Monitor 100
50/50
Document number 42TM50-25
Revision A
Page 48 of 48
4: Maintenance and Troubleshooting