weld defect - guided ultrasonics · 2018-08-07 · • weld defect was positively identified using...

1
Distance (m) A close up view of the defected weld with lack of root penetration which is visually unobservable. A radiograph of the defected weld with lack of root penetration confirmed by the dark circumferential line. Good Weld Weld Defect 3” Gas line Painted surface Job Details Weld defect was positively identified using standard tools available in the Wavepro TM software Subsequent prove up using Radiographic Testing (RT) confirms a 85% lack of root penetration at positions reported in the unrolled pipe display Main Findings Equipment: With the advanced interpretation tools such as frequency sweeping and C-Scan, welds can be screened for defects as part of the guided wave inspection. Wavemaker ® G3 EFC Solid Ring Clock position Guided Ultrasonics Ltd. Wavemaker House, The Ham, Brentford, TW8 8HQ United Kingdom Email : [email protected] Website : www.guided-ultrasonics.com Tel: +44 845 605 0227 ©2016 Guided Ultrasonics Ltd. All rights reserved. 2016CaseStudy12_rev0 Amplitude (dB)

Upload: others

Post on 03-Apr-2020

10 views

Category:

Documents


4 download

TRANSCRIPT

Distance (m)

A close up view of the defected weld with lack of root penetration which is visually unobservable.

A radiograph of the defected weld with lack of root penetration confirmed by the dark circumferential line.

Good WeldWeld Defect

• 3” Gas line

• Painted surface

Job Details

• Weld defect was positively identified using standard tools available in the WaveproTM

software

• Subsequent prove up using Radiographic Testing (RT) confirms a 85% lack of root penetration at positions reported in the unrolled pipe display

Main Findings

Equipment:

With the advanced interpretation tools such as frequency sweeping and C-Scan, welds can be screened for defects as part of the guided wave inspection.

Wavemaker® G3 EFC Solid Ring

Cloc

k po

sitio

n

Guided Ultrasonics Ltd.Wavemaker House,

The Ham, Brentford, TW8 8HQUnited Kingdom

Email : [email protected] : www.guided-ultrasonics.comTel: +44 845 605 0227 ©2016 Guided Ultrasonics Ltd. All rights reserved.2016CaseStudy12_rev0

Ampl

itude

(dB)