welcome din rail product training isolator/mcb/rcd/rcbo

23
© 2008 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Welcome DIN Rail product training ISOLATOR/MCB/RCD/RCBO

Upload: urbana

Post on 11-Jan-2016

27 views

Category:

Documents


2 download

DESCRIPTION

Welcome DIN Rail product training ISOLATOR/MCB/RCD/RCBO. Load Disconnector Switch (Isolator). Rated current: 40, 63, 80, 100 & 125A Rated voltage: AC 230/400V Number of poles: 1p, 2p, 3p, 4p Module unit: 1 MU = 17.5 mm - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

© 2008 Eaton Corporation. All rights reserved.

This is a photographic template – your photograph should fit precisely within this rectangle.

Welcome DIN Rail product training

ISOLATOR/MCB/RCD/RCBO

Page 2: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

2 2

Load Disconnector Switch (Isolator)

Rated current : 40, 63, 80, 100 & 125A

Rated voltage : AC 230/400V

Number of poles : 1p, 2p, 3p, 4p

Module unit : 1 MU = 17.5 mm

Terminals : Twin-purpose terminal, (lift/open mouthed) with

guide for secure connection

Page 3: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

4 4

Miniature Circuit Breaker

Definition and benefit

Function

Product range

Technical data

Accessories

Summary

Page 4: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

5 5

Miniature Circuit Breaker

Function of MCB

Protection against Overloads – a thermal delay (bi-metal) release initiates the disconnecting process and separates the contacts.

Protection against Short circuits - an electromagnetic instantaneous release (hammer- armature) performs the disconnecting process and separates the contacts.

Page 5: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

6 6

Miniature Circuit Breaker

Tripping Characteristics

B – for line and cable protection in residential building installations (lighting and socket circuits)

C – for line and cable protection, particularly for electrical systems and equipment with higher making currents (groups of lamps)

D – for line and cable protection, particularly for electrical systems and equipment with very high making currents (welding transformers, motors)

Page 6: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

8 8

Miniature Circuit Breaker

Installation and removal without removing the busbar

Page 7: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

9 9

Miniature Circuit Breaker

Guide for secure terminal connection

Prevents missing the terminal when introducing the wire

Page 8: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

10 10

Miniature Circuit Breaker

Contact position indicator red/green

Page 9: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

11 11

Miniature Circuit Breaker STD series 2A-63A

Tested to : IEC/EN 60898

Rated breaking capacity : 10 kA; 6 kA; 4.5 kA

Rated current : 1 - 63 A

Rated voltage : AC 230/400V

: DC 48V per pole

Characteristic : B, C, D

Number of poles : 1p, 1+N, 2p, 3p, 3+N, 4p

Module unit : 1 MU = 17.5 mm

Terminals : Twin-purpose terminal (lift/open mouthed) with

guide for secure connection

Terminal capacity : 1 - 25 mm²

Page 10: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

12 12

Miniature Circuit Breaker 125A

Tested to : EN 60947-2

Rated breaking capacity : 25 kA

Rated current : 80 – 125 A

Rated voltage : AC 240/415V AC

: DC 60 V per pole

Characteristic : B, C, D

Number of poles : 1p, 2p, 3p, 3+N, 4p

Module unit : 1.5 MU = 27mm

Terminals : lift terminal

Terminal capacity : 1 - 50 mm²

Device height : 90 mm

Page 11: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

13 13

Miniature Circuit Breaker - accessories

Auxilliary Contact

Trip Contact

Undervoltage Release

230VAC

Shunt Trip

12-110VAC/12-60VDC

110-415VAC/110-220VDC

Page 12: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

14 14

Miniature Circuit BreakerSummary of Features

• Installation and removal of MCB without removing the bus bar

• 80 mm device height – compatible with DIN rail products

• Twin-purpose terminal (lift/open mouthed) with guide for secure connection

• both releases work independent of each other.

• Wide range of accessories, most items in snap-on design

• Internal tripping is independent of the toggle position , guarantees proper tripping even in case the operating toggle is blocked or held by the operator

Page 13: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

15 15

Definition & benefit

Function & Key Components

Product range

Features

Accessories

Applications

Summary

Residual Current Device

Page 14: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

16 16

Product range

• Rated current: 25, 40, 63, 80, 100A

Number of poles: 2p, 4p•

• Rated tripping current: 30, 100, 300mA

• Voltage systems: AC 240/415V AC

• Frequency: 50Hz

Residual Current Device

Page 15: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

17 17

Front printing

Standard ON/OFF

Nominal current

Short circuit strength

Nominal voltage

I∆N sensitivity

Contact position indicator

Terminal designation.

Test information

Residual Current Device

Page 16: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

19 19

• Additional safety!

contact position indicator

red/green

Features

Residual Current Device

Page 17: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

20 20

• Additional safety!

possibility to seal /

possibility to lock in

ON and OFF position

Features

Residual Current Device

Page 18: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

21 21

Flexible and big room for connection!

Twin purpose terminal

(lift/open mouth on bottom and top)

35 mm2 capacity

both sides compatible to bus bars

Features

Residual Current Device

Page 19: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

22 22

Combined Fault Current and Miniature Circuit Breaker (RCBO)

Definition and benefit

Specification

Place of installation

Application

Product line

Place of installation + features

Accessories

Summary

Page 20: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

23 23

Combined Fault Current andMiniature Circuit Breaker

DEFINITION

Residual Current Device and Miniature Circuit Breaker in one (RCBO)

ADVANTAGE

Protection against O/L, S/C and E/L in one unit.

Page 21: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

24 24

Combined Fault Current andMiniature Circuit Breaker

Single Module RCBO

-Electronic residual current device & MCB combination in one

-1p + N in only one 1 module

-Design IEC/EN 61009

-Breaking capacity 10kA

-Type B, C & D.

Page 22: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

25 25

Combined Fault Current andMiniature Circuit Breaker

Contact positon indicator red/green

Contact positon indicator red/green

Can be sealed with leads in the ON or OFF position

Can be sealed with leads in the ON or OFF position

Twin-purpose terminal (lift/open mouthed) above and below

Twin-purpose terminal (lift/open mouthed) above and below

Lift terminalLift terminal

Benefits & Features

• single module, compact 17.5mm Width.• Height 120mm.• Frame size 45mm compatible with other

modular components.• Contact position indicator red/green.• Can be sealed with leads in the ON or OFF

position. • open mouthed/lift terminals top & bottom.• Fixed connected neutral length 950mm.• Can be connected in a STD pan assembly• Terminal capacity 25mm

Page 23: Welcome  DIN Rail product training ISOLATOR/MCB/RCD/RCBO

27 27