website ppt
DESCRIPTION
slides for PPTTRANSCRIPT
![Page 1: Website Ppt](https://reader035.vdocuments.us/reader035/viewer/2022062513/5555c256d8b42aaf158b459d/html5/thumbnails/1.jpg)
Safety Spreadsheet
Fall Protection - Floor & Wall Openings 0 0#DIV/
0!
16 Guardrails constructed to withstand 200 lb LoadsOSHA 1926.502 (b)(3)
0 0#DIV/
0!
17 Guardrails installed at leading edge w/fall distance 6' or moreOSHA 1926.501 (b)(13)
0 0#DIV/
0!
18 Guardrails installed at wall openings 19" wide or moreOSHA 1926.502(b)(2)(iv)
0 0#DIV/
0!
19 Guardrails installed at window openings w/ sill height < 39" OSHA 1926.501 (b)(14)
0 0#DIV/
0!
20 Guardrail Component Heights: Top Rail 42" +/- 3"OSHA 1926.502(b)(1)
0 0#DIV/
0!
21 Mid Rail 21" OSHA 1926.502(B)(2)
0 0#DIV/
0!
22 Toe Board 4" HighOSHA 1926.502(j)(3)
0 0#DIV/
0!
23 Floor Openings>2"x2" covered OSHA 1926.500(b), 0 0#DIV/
0!
24 Floor Openings>2"x2" marked "Cover" or "Hole"OSHA 1926.502(i)(4)
0 0#DIV/
0!
25 Impalement hazards are guarded OSHA 1926.701(b) 0 0#DIV/
0!
![Page 2: Website Ppt](https://reader035.vdocuments.us/reader035/viewer/2022062513/5555c256d8b42aaf158b459d/html5/thumbnails/2.jpg)
Framing Structural Damage
2003 IRC Section 602.6 Drilling and notching-studs.
Studs in an exterior or bearing wall may be cut or notched to a depth not exceeding 25 percent of its width.
Studs in nonbearing walls may be notched to a depth not to exceed 40 percent of a single stud width.
Any stud may be bored or drilled, provided that the diameter of the resulting hole is no greater than 40 percent of the stud width, the edge of the hole is no closer than 5/8 inch to the edge of the stud
![Page 3: Website Ppt](https://reader035.vdocuments.us/reader035/viewer/2022062513/5555c256d8b42aaf158b459d/html5/thumbnails/3.jpg)
Foundations
Beams
Beams are not being consistently installed with the correct width
Plans called for 12” wide beams
Beam is 9 ½” wide at bottom
![Page 4: Website Ppt](https://reader035.vdocuments.us/reader035/viewer/2022062513/5555c256d8b42aaf158b459d/html5/thumbnails/4.jpg)
Framing
Studs over-notched to allow for plumbing stacks
![Page 5: Website Ppt](https://reader035.vdocuments.us/reader035/viewer/2022062513/5555c256d8b42aaf158b459d/html5/thumbnails/5.jpg)
Enclosure
3 LAWS OF THERMODYNAMICS HOT GOES TO COLD HIGH PRESSURE GOES TO LOW PRESSURE WET GOES TO DRY
KEEP BULK WATER OUT LET WATER VAPOR ESCAPE ALLEVIATE LOW PRESSURE IN HOUSES
![Page 6: Website Ppt](https://reader035.vdocuments.us/reader035/viewer/2022062513/5555c256d8b42aaf158b459d/html5/thumbnails/6.jpg)
SAFETY
Scaffolds
Unsafe scaffold
![Page 7: Website Ppt](https://reader035.vdocuments.us/reader035/viewer/2022062513/5555c256d8b42aaf158b459d/html5/thumbnails/7.jpg)
SWPPP Permits SWPP Plans Inspection Reports Posted Notices Training Site Maintenance Terminations Record Keeping
![Page 8: Website Ppt](https://reader035.vdocuments.us/reader035/viewer/2022062513/5555c256d8b42aaf158b459d/html5/thumbnails/8.jpg)
SWPPP
Site Maintenance
Blowable trash is not being contained, and regularly removed