we understand water. - gruenbeck.de · only with protecteliq:a32 and protecteliq:a40: screw the...

32
We understand water. Safety device | protectliQ Operation manual

Upload: others

Post on 16-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

We understand water.

Safety device | protectliQ

Operation manual

Page 2: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Central Contact Germany

Sales Phone +49 9074 41-0

Technical Service Phone +49 9074 41-333 Fax +49 9074 41-120

Availability Monday to Thursday 7:00 am - 6:00 pm

Friday 7:00 am - 4:00 pm

Your local point of contact: see accompanying list of representatives

Copyright The manufacturer reserves the copyright to this manual. Without the written consent of Grünbeck Wasseraufbereitung GmbH, no part of this manual may be reproduced in any way, nor may any part be processed, duplicated or distributed using electronic systems. Contraventions of the aforementioned requirements shall be subject to compensation in damages.

We reserve the right to modifications. © by Grünbeck Wasseraufbereitung GmbH

Translation of the original operation manual Edition of the manual: July 2018 Order number: TD3-FA000en_025

Page 3: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Table of contents

3 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

Table of contents

1 About this manual .......................... 4

1.1 Other applicable documents ........... 4 1.2 Target group ................................... 4 1.3 Storage of the documents ............... 4 1.4 Symbols used ................................. 4 1.5 Typographical conventions ............. 5 1.6 Validity of the manual ..................... 6 1.7 Type designation plate .................... 7

2 Safety .............................................. 8

2.1 Safety measures ............................. 8 2.2 Technical safety instructions ........... 9 2.3 Regulations ................................... 10 2.4 Responsibilities of the

tradesperson ................................. 10 2.5 Responsibilities of the owner-user 11

3 Product description ..................... 12

3.1 Intended use ................................. 12 3.2 Product components ..................... 12 3.3 Accessories .................................. 13 3.4 Functional description ................... 13

4 Installation .................................... 14

4.1 Requirements in relation to the installation site .............................. 14

4.2 Checking the scope of supply ....... 15 4.3 Installing the product ..................... 16

5 Commissioning ............................ 17

6 Operation ...................................... 18

6.1 Display symbols ............................ 18 6.2 Manual mode ................................ 19

7 Cleaning, inspection, maintenance ................................. 20

7.1 Cleaning ....................................... 20 7.2 Functional test .............................. 20 7.3 Battery replacement ..................... 21 7.4 Spare parts ................................... 22 7.5 Wearing parts ............................... 22

8 Fault .............................................. 23

8.1 Signals .......................................... 23

9 Disposal ........................................ 24

10 Technical specifications ............. 25

EC Declaration of Conformity .............. 27

Notes ...................................................... 28

Notes ...................................................... 29

Index ....................................................... 30

Page 4: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

About this manual

4 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

1 About this manual

1.1 Other applicable documents

The following documents shall be deemed as applicable

documents for the safety device protectliQ:

● The manuals of all accessories used shall apply.

1.2 Target group

This manual is intended for specialist installers and owners/users.

1.3 Storage of the documents

This manual and all other applicable documents must be kept so

as to be available if required.

1.4 Symbols used

This symbol identifies instructions that you must comply with for

your personal safety.

This symbol identifies instructions that you must comply with in

order to avoid damage to property.

This symbol identifies important information about the product or

its handling.

Page 5: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

About this manual

5 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

This symbol identifies work that is only allowed to be carried out

by specialist installers. In Germany, the installation company

must be registered in an installation directory of a water supply

company acc. to §12(2) AVB Wasser V (German Ordinance on

General Conditions for the Supply of Water).

1.5 Typographical conventions

The following typographical conventions are used in this manual:

1.5.1 Buttons

Buttons are depicted with a doted outline:

Button

1.5.2 Instructions

Single-step instructions or instructions where the sequence of the

actions is unimportant are indicated as follows:

► Action

Multi-step instructions in which the sequence must be complied

with are indicated as follows:

Page 6: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

About this manual

6 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

1. First step

a First action in the first step

b Second step of the first action

2. Second action

Results of an instruction are indicated as follows:

» Result

1.5.3 Lists

Bullet symbols used:

● First list point (level 1)

• First bullet point (level 2)

• Second bullet point (level 2)

● Second list point (level 1)

1.6 Validity of the manual

This manual applies to the following products:

● Safety device protectliQ:A20

● Safety device protectliQ:A25

● Safety device protectliQ:A32

● Safety device protectliQ:A40

Page 7: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

About this manual

7 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

1.7 Type designation plate

The type designation plate is located on the housing of the

protectliQ.

Please specify the data shown on the type designation plate in

order to speed up the processing of your enquiries or orders.

Therefore enter the necessary information in the table below to

have it readily available whenever necessary.

● Product designation: protectliQ:A___

● Order number: _____________

Page 8: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Safety

8 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

2 Safety

WARNING: Contamination of drinking water due to improper

handling.

● Risk of infectious diseases.

► Only have installation and commissioning carried out by a

qualified technician.

2.1 Safety measures

● Carefully read this manual before operating your product.

● Install the product in a frost-free room. Otherwise, the

product may suffer irreparable damage. The consequence

can be a water damage.

● Only use genuine spare parts for maintenance or repair. If

unsuitable spare parts are used, the warranty for your

product will be void.

● Do not use products which have a damaged power supply

cable. This can lead to injuries due to electric shock. Have

damaged power supply cables replaced without delay.

● Only have persons working on your product who have read

and understood this manual and that are qualified to do

such work on account of their vocational training.

● Only operate the product if all components are installed

properly.

● Safety device must never be removed, bridged or

otherwise tampered with.

Page 9: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Safety

9 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

2.2 Technical safety instructions

This manual contains information and instructions that you must

comply with for your own personal safety as well as to avoid

damage to property. The information and instructions are

highlighted by a warning triangle and have the following structure:

CAUTION: Type and source of danger

● Possible consequences

► Preventive measures

The following signal words were defined subject to the degree of

danger and may be used in the present document:

● DANGER means that serious or fatal injuries will occur if

the corresponding precautionary measures are not taken.

● WARNING means that serious or fatal injuries may occur if

the corresponding precautionary measures are not taken.

● CAUTION means that minor injuries may occur if the

corresponding precautionary measures are not taken.

● NOTE (without a warning triangle) means that damage to

property may occur if the corresponding safety measures

are not taken.

Page 10: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Safety

10 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

2.3 Regulations

When installing and starting up the system, amongst others

comply with the following regulations and guidelines:

● Statutory regulations on environmental protection

● Provisions of the employers' liability insurance associations

● DIN EN 806 Specifications for installations inside buildings

conveying water for human consumption

● VDI 6023 part 6

2.4 Responsibilities of the tradesperson

Comply with the following specifications to ensure correct and

safe function of the product:

● Only perform activities described in this manual.

● Perform all activities in accordance with all applicable

standards and regulations.

● Brief the owner/user on the function and operation of the

product.

● Advise the owner/user of the maintenance of the product.

● Instruct the owner-user about possible dangers that can

arise during operation of the product.

Page 11: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Safety

11 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

2.5 Responsibilities of the owner-user

Comply with the following specifications to ensure correct and

safe function of the product:

● Assign the installation and commissioning to a specialist

technician.

● Have the product explained to you by the specialist

installer.

● Only perform activities described in this manual.

● Do not carry out any activities that are explicitly indicated

for a specialist installer.

● Only use this product in accordance with its designated

application.

● Make sure that the required inspection and maintenance

work is carried out.

● Keep this manual.

Page 12: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Product description

12 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

3 Product description

3.1 Intended use

The safety device protectliQ is a product for the protection from

water damage in one and two-family homes.

The safety device protectliQ protects the rooms equipped with a

water sensor.

3.2 Product components

No. Designation No. Designation

1 Union nut 2 Insert

3 Flat seal 4 Ball valve

5 Type designation plate 6 Lid

7 Batteries 8 Control button

9 Release for hand lever 10 Hand lever

11 Water sensor

Page 13: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Product description

13 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

3.3 Accessories

You can retrofit your product with additional accessories. Please

contact your local Grünbeck representative or Grünbeck’s

headquarters in Hoechstaedt for details.

Image Products Order no.

Power supply unit 126 802

The protectliQ can

optionally be operated with a power supply unit. Whenever possible, the power supply from the power supply unit is used. The service life of the batteries is thus considerably extended.

Water sensor with 2 m 126 805

Water sensor with 10 m cable

126 815

A second water sensor with a cable of up to 10 m in length can be connected. To do this, use the free screw-type terminals on the printed circuit board of the

protectliQ.

3.4 Functional description

The connected water sensor permanently monitors critical

locations in moist-prone rooms such as kitchens, bathrooms or

laundry rooms, etc. In case water collects on the floor, the water

sensor responds and the protectliQ automatically closes the water

supply.

Page 14: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Installation

14 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

4 Installation

The installation of a safety device protectliQ represents a major

intervention into the drinking water system and may only be

performed by a specialist installer.

4.1 Requirements in relation to the installation site

Observe local installation directives, general guidelines and

technical specifications. The installation site must be frost-proof

and ensure the system's protection from chemicals, dyes,

solvents and vapours.

Page 15: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Installation

15 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

4.2 Checking the scope of supply

No. Designation No. Designation

1 Union nut 2 Flat seal

3 Insert 4 protectliQ

5 Ball valve 6 Reduction*

7 Flat seal* o. P. Operation manual

* only for protectliQ:A32 and protectliQ:A40

► Check the scope of supply for completeness and possible

damage.

Page 16: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Installation

16 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

4.3 Installing the product

Only with protecteliQ:A32 and protecteliQ:A40:

► Screw the reducers onto the ball valve with the

appropriate flat seal.

1. Mount the ball valve (ball closed) with inserts, union nuts

and seals in the pipe.

2. Check that the hand lever is set to "closed".

3. Press the release button and turn the hand lever to

"closed" if this is not the case.

4. Connect the protecteliQ to the ball valve.

5. Tighten the screw.

6. Check the tightness.

7. Perform a function test (refer to chapter 7.2).

8. Mount the water sensor firmly on the floor using the hole.

Page 17: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Commissioning

17 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

5 Commissioning

1. Pull the cover off upwards.

2. Insert the batteries into the battery holder. Pay attention to

the polarity.

» The valve opens automatically

3. Close the cover by inserting its bottom end into the housing

and pressing until it clicks into place.

4. Perform a function test. (refer to chapter 7.2)

5. Check that the water sensor is positioned correctly.

Page 18: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Operation

18 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

6 Operation

6.1 Display symbols

Leakage (orange)

Flashes if there is moisture at the water sensor.

Battery OK (green)

Lights up briefly when the button is pressed, if the

battery is still OK.

Battery flat (red)

Flashes 4 weeks before battery life expires

Buzzer can be muted for 24 hours

To do this, press the control button

If the battery is not changed, the valve closes the

feed line. The control unit then switches off

Page 19: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Operation

19 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

6.2 Manual mode

Manual mode allows you to adjust the valve manually (by hand).

When the batteries of the protectliQ are completely flat, the valve

closes automatically. In this case, you can open the valve

manually in order to continue to have a water supply with flat

batteries.

6.2.1 Adjusting the valve by hand

1. Press and hold the release (red button).

2. Turn the hand lever firmly through 90° to the desired

position.

Page 20: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Cleaning, inspection, maintenance

20 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

7 Cleaning, inspection, maintenance

7.1 Cleaning

1. Only clean the outside of the product.

2. Do not use any sharp or abrasive cleaning agents, because

they can damage the surface.

3. Wipe the housing with a damp cloth.

7.2 Functional test

A regular function test increases the operational reliability of

your product.

► Perform a functional test every six months.

To conduct a functional test, proceed as follows:

1. Immerse the water sensor in water or alternatively bridge it

with a metallic object.

» The protectliQ is functioning if it closes the water supply.

Page 21: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Cleaning, inspection, maintenance

21 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

2. Check the tightness at a withdrawal point.

» The protectliQ is leak-proof if no water flows after a short

drop in pressure.

3. Dry the contacts.

4. Press the control button.

» The protectliQ opens the water supply.

5. Repeat steps 1 and 2 if you have multiple water sensors

connected.

7.3 Battery replacement

CAUTION: protectliQ out of operation with batteries that have

not been replaced

● The protectliQ offers no protection.

► Replace flat batteries in good time.

1. Pull the cover off upwards.

2. Remove the flat batteries from the battery holder.

3. Insert the new batteries into the battery holder.

» The valve opens automatically

4. Close the cover by inserting its bottom end into the housing

and pressing until it clicks into place.

» The protectliQ offers protection again.

Page 22: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Cleaning, inspection, maintenance

22 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

7.4 Spare parts

NOTE: Risk of damage to the product if unsuitable spare parts

are used.

● Risk of functional impairment, malfunctions and loss of

warranty.

► Only use genuine spare parts.

You may order spare parts and consumables from your local

Grünbeck representative (refer to the internet at

www.gruenbeck.com).

7.5 Wearing parts

NOTE: Danger of damaging the system if unsuitable wearing

parts are used.

● Risk of functional impairment, malfunctions and loss of

warranty.

► Only use genuine wearing parts.

Wearing parts are listed below:

● Gaskets

Page 23: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Fault

23 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

8 Fault

The safety device protectliQ indicates faults by means of the

LEDs. If malfunctions do occur that cannot be remedied by the

instructions given below, contact Grünbeck's technical

service/authorised service company.

► Keep your equipment data (refer to chapter 1.7) ready.

8.1 Signals

Observation Explanation Remedy

Audible sound

Red LED is

flashing

Batteries almost

flat.

Replace the

batteries within the

next 4 weeks.

No water Moisture at the

water sensor.

Check the water

sensor.

Eliminate the

cause.

Press the control

button.

No water.

ProtectliQ closed.

Device does not

react

Batteries are flat. Replace the

batteries.

Page 24: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Disposal

24 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

9 Disposal

► Do not dispose of the packaging, the product and the

accessories with the household waste.

► Comply with the applicable national regulations for

disposal.

► Make sure that the packaging, the product and the

accessories are disposed of properly.

Page 25: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Technical specifications

25 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

10 Technical specifications

Dimensions and weight A20 A25 A32 A40

A Height up to centre of

connection [mm] 100

B Depth to centre of connection

[mm] 40

C Projection exceeding centre [mm] 143

D Installation length with/without screw connection

[mm] 70/165 70/152 160/251 160/283

Operating weight, approx. [kg] 1.5 1.5 2.5 3.0

Page 26: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Technical specifications

26 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

Connection data A20 A25 A32 A40

Nominal connection diameter DN 20 DN 25 DN 32 DN 40

Nominal pressure PN 16

Nominal flow Qn [m3/h] 6.5 8 9 12

Battery type control unit Mignon AA 4x

Power supply of control unit (optional power supply plug)

[VDC] 5

Max. power input power supply plug

[A] 1

Power supply (battery operation only)

[VDC] 6

Max. power input (battery operation only) (while valve opens/closes)

[A] 0.2

General data A20 A25 A32 A40

Field of application Drinking water cold, min. 20 µS/cm

Max. water temperature [°C] 30

Max. ambient temperature [°C] 40

DVGW registration number Certification pending

Order no. 126 400 126 405 126 410 126 415

Page 27: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

EC Declaration of Conformity

27 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

EC Declaration of Conformity

In accordance with the EU Low-Voltage Directive 2014/35/EU, Appendix IV

This is to certify that the system designated below meets the safety and health requirements

of the applicable European guidelines in terms of its design, construction and execution.

This certificate will become invalid if the system is modified in a way not approved by us.

Safety device protectliQ

Serial no.: refer to type designation plate

The aforementioned system also complies with the following directives and provisions:

• EMC (2014/30/EU)

The following harmonised standards have been applied:

• DIN EN 61000-6-2:2006-03 • DIN EN 61000-6-3:2011-09

• DIN EN 60335-1:2012-10

The following national standards and regulations have been applied:

• DVGW VP 638:2004-11

Responsible for documentation: Dipl.-Ing. (FH) Markus Pöpperl

Manufacturer

Grünbeck Wasseraufbereitung GmbH

Josef-Grünbeck-Str. 1

89420 Hoechstaedt/Germany

Hoechstaedt, January 2018

Dipl. Ing. (FH) Markus Pöpperl

Head of Department for Product Implementation and Product Launch

Page 28: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Notes

28 | 32

Notes

Page 29: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Notes

29 | 32

BA

_T

D3

-FA

00

0e

n_

02

5_p

rote

cliQ

.DO

CX

Notes

Page 30: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Index

30 | 32

Index

A

Accessories ................................ 13

B

battery replacement .................... 21

C

Cleaning ..................................... 20

D

Display messages ...................... 23

F

Fault ........................................... 23

Functional test ....................... 17, 20

I

Inspection ................................... 20

Installation ................... 8, 10, 11, 14

M

Maintenance ................ 8, 10, 11, 20

N

No water ..................................... 23

P

Product components................... 12

S

Safety ....................................4, 8, 9

Spare parts ............................. 8, 22

T

Technical specifications .............. 25

Type designation plate ........... 7, 27

Page 31: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve
Page 32: We understand water. - gruenbeck.de · Only with protecteliQ:A32 and protecteliQ:A40: Screw the reducers onto the ball valve with the appropriate flat seal. 1. Mount the ball valve

Grünbeck Wasseraufbereitung GmbH Josef-Grünbeck-Strasse 1 89420 Hoechstaedt a. d. Donau GERMANY

For more information, go to www.gruenbeck.com

+49 9074 41-0

+49 9074 41-100

[email protected] www.gruenbeck.com