we need more power scotty! - embedded tech trends · 2017. 3. 30. · •air-cooled vita 48.1...

16
© 2013 Mercury Systems, Inc. We Need More Power Scotty! Getting the Heat Out: Innovations for Cooling the Next Generation of Embedded Computing Electronics Dan Coolidge Sr. Mechanical Engineer Darryl McKenney VP, Engineering Services Embedded Technology Trends January 21, 2013

Upload: others

Post on 27-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • © 2013 Mercury Systems, Inc.

    We Need More Power Scotty! Getting the Heat Out:

    Innovations for Cooling the Next Generation of Embedded Computing Electronics

    Dan Coolidge Sr. Mechanical Engineer

    Darryl McKenney VP, Engineering Services

    Embedded Technology Trends January 21, 2013

  • 2 © 2013 Mercury Systems, Inc.

    Thermal Challenges Overview

    • Background – What’s the problem?

    • A brief history of power: – Module Power

    – Mezzanine Module Power

    • Integrated Module Solutions – Air Cooled Vita 48.1

    – Conduction Cooled Vita 48.2

    – Air Flow-ByTM VITA 48.7

    • VITA 48 Sub-System Solutions – Quick reaction development platforms

    – Long term deployment solutions

    • Summary

  • 3 © 2013 Mercury Systems, Inc.

    The Creation of SW&P Opportunities…

    How do we do more with less?

    Size :

    Weight :

    Power :

    “Captain…. I’m giving you all she’s got!!!”

  • 4 © 2013 Mercury Systems, Inc.

    VME to VXS to VPX Module Power Progression

    0

    50

    100

    150

    200

    250

    VME VXS VPX

    Mo

    du

    le P

    ow

    er

    (W)

    Module Power Progression

    Carrier Modules

    Compute Modules

    Graphic Modules

    1990’s

    2000’s

    Present

  • 5 © 2013 Mercury Systems, Inc.

    XMC Mezzanine Module Power

    Mezzanine power has doubled every 4 years for the past 8 years!!!

    0

    20

    40

    60

    80

    100

    120

    2000 2004 2008 2012

    Mo

    du

    le P

    ow

    er

    (W)

    Mezzanine Power Progression

    PMC

    XMC

    FMC

    MXM

  • 6 © 2013 Mercury Systems, Inc.

    Cooling Technology Effectiveness A/C vs. C/C vs. AFB

    Many of today’s high powered modules cannot be cooled using legacy cooling approaches.

    0

    50

    100

    150

    200

    250

    300

    A/C C/C AFB

    Max

    Mo

    du

    le P

    ow

    er

    (W)

    Cooling Technology

    Cooling Technology Effective Range

  • 7 © 2013 Mercury Systems, Inc.

    Mercury Module Cooling Techniques

    • Air-cooled VITA 48.1 – Minimize air leakage and bypass

    areas by increasing effective heatsink area

    – Utilize 3-dimensional integrated heat-sinks

    – Increase air flow (CFM) across the heat-sinks

    • Conduction Cooled VITA 48.2 – Module to chassis interface thermal

    reduction

    – Improve Wedge-lock performance

    – Control the thermal path for heat dissipation

    New Air Flow-By™ VITA 48.1 & 48.7

  • 8 © 2013 Mercury Systems, Inc.

    Integrated XMC Thermal Solutions – Air Cooled

    • Need: Standards based approach to bring heat from the mezzanine modules to the carrier modules heatsink.

    • Solution: Add “hooks” for a thermal bridge between the carrier module heatsink and the mezzanine module heatsink.

    • Result: A thermal solution that is compliant to standards and allow for a wide range of mezzanine modules to be placed on a host while limiting any potential changes to a single component.

  • 9 © 2013 Mercury Systems, Inc.

    Air-Cooled Thermal Analysis Comparison

    5°C Processor Thermal Reduction

    ½ Order of Magnitude

    Impact on MTBF

    Without Integrated thermal bridge

    With Integrated thermal bridge

  • 10 © 2013 Mercury Systems, Inc.

    Integrated Thermal Solutions – Conduction Cooled

    • Need: Standards based approach to bring heat from the mezzanine modules to the carrier module cold plate.

    • Solution: Take advantage of allowances in ANSI/VITA 20 specification to allow for the thermal ribs to be removable. Add a mezzanine cold plate that is attached to the carrier module cold plate.

    • Result: Staying compliant to standards allows for a wide range of mezzanine modules to be placed on a host while limiting any potential changes to a single component.

  • 11 © 2013 Mercury Systems, Inc.

    Integrated Thermal Solutions – Conduction Cooled “New Solution”

    • Max mezzanine module power: – From: 5-7 Watt Maximum

    – To: 30-50 Watt Maximum

    • Cooling method – From: Indirect path from a component to

    the PCB to the cold plate.

    – To: Direct path from the component to the integrated cold plates.

    • Thermal interface area: – From: 2 square inches (legacy solution)

    – To: 12 square inches (new solution)

    FROM

    TO

  • 12 © 2013 Mercury Systems, Inc.

    VITA 48.7 / VITA 48.1 Circuit Card Assembly

    • Air is blown over the external covers for dual sided cooling.

    • AFB covers wrap around existing modules to maximize re-use.

    • 1” pitch modules.

    • 200+ W per slot cooling capacity in rugged deployments.

    • Designed for optimization of C-SWAP.

    HDS6601

  • 13 © 2013 Mercury Systems, Inc.

    VPX Air Flow-By (AFB) QRC Versatility

    • AFB modules can be used in commercial VITA 48.1 chassis or in rugged VITA 48.7 compliant chassis.

    • AFB modules can be used side by side with standard A/C modules in a VITA 48.1 chassis.

    • AFB chassis are capable of providing C/C slots for ease of transition from legacy technologies.

    16-Slot AFB Chassis 6-Slot AFB Chassis

    “Oh Captain, she’ll give us over 200 watts per slot!”

  • 14 © 2013 Mercury Systems, Inc.

    Mercury AFB Deployment Systems (11-slot and 13-slot available)

    AFB provides subsystem level flexibility to allow for higher max ambient OR increased heat load OR decreased fan power…

    AFB Deployed 13-Slot System Impacts: • Conduction Cooled to AFB modular upgradability. • Weight reduction of over 20% (18.4 lbs.) • Reduced system power by greater than 5%. • MTBF increased by ½ an order of magnitude. • Equivalent system footprint to provide a drop-in upgrade.

  • 15 © 2013 Mercury Systems, Inc.

    Thermal Challenges Summary

    • By focusing on standard VITA based solutions for cooling today’s high powered modules, Mercury is uniquely positioned to maximize 3rd party leverage and product velocity.

    • Mercury is able to apply these solutions across a wide range of products (carriers, high compute devices, graphic modules…) across multiple use cases (air-cooled, conduction cooled, AFB….)

    • These thermal solutions allow for VPX systems to be deployed in more extreme environments, operate more efficiently, and last longer than legacy solutions.

    Learn more at http://download.mrcy.com/thermal

    Air Flow-By is a trademark of Mercury Systems, Inc.

    AFB

    http://download.mrcy.com/thermalhttp://download.mrcy.com/thermal

  • TM

    © 2013 Mercury Systems, Inc.

    Q & A Thank You