Waveguide for Station 5
M. Yoshida
(Osaka Univ.)
![Page 2: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/2.jpg)
• Test assembly– 450cm-long– Select better fiber canes
• External waveguide– 290cm
• Internal waveguide– 140cm
• Quality assessment has been done in Osaka Univ.
![Page 3: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/3.jpg)
Fiber preparation- Population of measured fiber brightness -
• Cut fibers into 450cm canes• Glue fibers on test cookies• Photo of flash reflection• LED trasmission
12 bad fibersrejected
![Page 4: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/4.jpg)
Connector parts of waveguide for station 5
• Bulkhead/Lead connector (1A / 2A)– 1.10 mm drilling with count
ersunk hole on the back end (by G-Tech)
• 22-way connector (3A)– 1.08 mm holes by 1.067 m
m drill (AC precision)• D0 connector
– 1.067 mm drilling (Fermilab)
• Flexible conduit– Adaptaflex PAFS21 and P
AFS28• Heat shrink tube
![Page 5: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/5.jpg)
External waveguide
![Page 6: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/6.jpg)
Internal Waveguide
1400mm
1-20
21-42
43-64
65-86
87-108
109-128
11 AA 3A3A3B3B1
2
3
4
5
6
1-128
![Page 7: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/7.jpg)
11 AA SurfaceSurface
1 - 20
1 - 22
1 - 22
1 - 22
1 - 22
1 - 20
3A Surface3A Surface
1-1
1-2
1-3
1-4
1-5
1-6
Internal Connector (1 A,3 A)
![Page 8: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/8.jpg)
External Connector( D0,2A)
1 2 3 4 5 6 7 8
121 122 123 124 125 126 127 128
22 A SurfaceA Surface
D0 SurfaceD0 Surface
![Page 9: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/9.jpg)
Mechanical strength of the external waveguide
• D0 connector boot and flexible conduit can be detached by pulling by hand
• Found that heat shrink tube at the connection does not have enough strength
• Epoxy glue at the connections, and then covered by heat shrink tube
• Also, we will find better heat shrink tube– Glue paint on inner wall of the
tube
![Page 10: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/10.jpg)
Flash light reflection- External waveguide -
• No fiber has reflection at D0 connector
• One fiber has reflection at lead connector end– Incomplete optical
cement / Air bobble (?)– Damage of larger
diameter fiber (?)– Need more careful
treatment and feedback
![Page 11: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/11.jpg)
Flash light reflection- Internal waveguide -
• All the fiber have no reflection light• Slight damage on cladding layer of the 5th 22-way connector• The problem seems to be just on the surface• Could be recovered by final polishing at Fermilab
![Page 12: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/12.jpg)
Channel Assignment
• Inject light from a clear fiber to connector surface
• Scan injection point by hand
• Take movie
• Perfect assignment on all the connectors!
camera
waveguidefiberscan
handy flash
![Page 13: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/13.jpg)
LED transmission test- External waveguide -
• All the fiber have good transmission within 10%
10%
#16 13170
![Page 14: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/14.jpg)
LED transmission test- Internal waveguide -
10%
• All the fiber have good transmission within 10%
11914 (#87)
![Page 15: Waveguide for Station 5 M. Yoshida (Osaka Univ.)](https://reader030.vdocuments.us/reader030/viewer/2022032607/56649ebb5503460f94bc32f4/html5/thumbnails/15.jpg)
Summary• The first production of external/internal waveguide show good trans
mission in all the channels.
• 3 bundle with test cookies have been delivered (675 fibers in total)– 450 cm long
• Check bad fibers by Takatomi and Hideyuki, and send them back to G-Tech in this week.
• G-Tech will ship 5 sets of waveguides to Fermilab in the end of Feb.
• The fabrication process will be improved by:– Fixation by glue at the conduit connections– Better heat shrink tube with glue painted inside– More careful gluing on the connector surface– Strict rejection of larger diameter fiber