wastewater specialty catalog 2002-2003 - conrads … · indian river 6031 s. straits highway...

20
Milan Engineered Systems, a division of Milan Supply Company, has built its reputation with quality products, competitive prices, and dedication to outstanding service. Product lines that encompass Wastewater Pumps and accessories, Control Panels, Wastewater Treatment Systems and Disposal Field accessories, point to our commitment to the industry. Milan Engineered Systems participates in ongoing education, has a concern for the public health and the preservation of the environment. Contact Milan for your wastewater system needs. Location Address Phone Number Fax Number Bay City 3566 N. Euclid Street 1•989•684•5873 1•989•684•7780 Cadillac 7877 Mackinaw Trail 1•231•775•5832 1•231•775•1467 Grayling 4603 Hanson Street 1•989•348•8832 1•989•348•7605 Howell 4950 Mason Rd. 1•517•552•1702 1•517•552•1706 Indian River 6031 S. Straits Highway 1•231•238•9200 1•231•238•9776 Mt. Pleasant 7125 E. Pickard 1•989•773•9100 1•989•772•3415 Sparta 9680 Sparta Avenue 1•616•887•5212 1•616•887•2555 Traverse City 6986 US31 S. 1•231•276•9282 1•231•276•6147 Wastewater Specialty Catalog 2002/2003

Upload: dinhdieu

Post on 06-Sep-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Milan Engineered Systems, a division of Milan Supply Company, has built itsreputation with quality products, competitive prices, and dedication tooutstanding service.

Product lines that encompass Wastewater Pumps and accessories,Control Panels, Wastewater Treatment Systems and Disposal Fieldaccessories, point to our commitment to the industry.

Milan Engineered Systems participates in ongoing education, has a concernfor the public health and the preservation of the environment.

Contact Milan for your wastewater system needs.Location Address Phone Number Fax NumberBay City 3566 N. Euclid Street 1•989•684•5873 1•989•684•7780Cadillac 7877 Mackinaw Trail 1•231•775•5832 1•231•775•1467Grayling 4603 Hanson Street 1•989•348•8832 1•989•348•7605Howell 4950 Mason Rd. 1•517•552•1702 1•517•552•1706Indian River 6031 S. Straits Highway 1•231•238•9200 1•231•238•9776Mt. Pleasant 7125 E. Pickard 1•989•773•9100 1•989•772•3415Sparta 9680 Sparta Avenue 1•616•887•5212 1•616•887•2555Traverse City 6986 US31 S. 1•231•276•9282 1•231•276•6147

Wastewater Specialty Catalog2002/2003

Page 2: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Sparta

Howell

Bay CityMt. Pleasant

Cadillac

Grayling

Indian River

Traverse City

Service Capabilities• Project Take-off• Application Review• Equipment Orientation• System Start up• System Assistance

System Specialists• Effluent & Sewage Lift Systems• OSI Sand Filters (ISF, RSF)• OSI AdvanTexTM

• Aerobic Treatment Units• High Strength Waste Treatment

"Michigan’s Most Diversified Supplier to the Wastewater Market."

"Assisting the Designerand Contractor"

MilanSupply

Branches

Table of ContentsBiotube Effluent Filters 3Ssptic Tank Effluent Pumping Systems 4Orenco Systems Pump Basins 5Goulds Pumps 6 - 7Myers Pumps 8 - 9Controls & Floats 10Pump Accessories 11Alarms & Float Charts 12Valves 13Disposal Field Accessories 14Septic Tank & Accessories 15PVC Pipe and Fittings Sch 40 16PVC Sewer Pipe & Fittings 17Tank Access Risers 18AdvanTexTM & Infiltrator 19

Page 3: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

How It WorksEffluent from the relatively clearzone of the septic tank, betweenthe scum and the sludge layers,enters the Boitube® Effluent Filterthrough its inlet holes.Effluent thenenters the space between thehousing and Boitubes, utilizing theentire screen surface for filtering.Particles larger than 1/8” aredetained in the interior space,where continued decomposition of

organic material occurs.Once the effluent has beenfiltered through the biotubes, itflows through the modulatingorifices at the outlet of the filter.If inflow becomes temporarilyexcessive, the fluid level in thetank will rise as the modulatingorifices slow the flow through thetank, allowing maximum settling ofsolids.

Features and Benefits • Improves effluent quality.

Average Total SuspendedSolids (TSS) is less than30 PPM, nearly 2 1/2 timeslower than a non screenedsystem!

• Allows for a smallerdiameter drainfield pipe.Lowers drainfield materialcosts.

• Superior patented design.Extends drainfield life.Reliable, corrosion-proofconstruction.

• Easy installation. Installsin minutes in new orexisting tanks.

• Available alarm. Indicateswhen maintenance isneeded.

• Ideal for variable-gradesewers. Allows reductionof the transport line sizeand associated costs.

• Custom sizes.

Sizes and Applications4” Diameter

Best for most residentialapplications

6” and 8” Diameter Ideal for larger residential

applications, such as largehomes or duplexes, or forsmall commercial flows.

12” and 15” Diameter For larger commercial

flows. Multiple filters maybe used to accommodatelarger flows.

Excellent for:• Gravity Septic Tank Filters

• Effluent Pumping Systems

• Dosing Siphon System

• Grease Trap Filters

• Industrial Process Filtering

• Groundwater Remediation

Source Recommended Filters2 or 3 bdrm single family homes FT0444-364 bdrm or larger homes FT0444-36, FT0654-36

FT0854-361000 gallons per day FT0854-36, FT1254-362000 gallons per day FT1254-36, FT1554-363000 gallons per day FT1254-36, FT1554-364000 gallons per day FT1554-365000 gallons per day FT1554-3610,000 gallons perday or more Multiple filtersUse multiple filters or deeper versions of standard filters toachieve desired screen area as an option at any flow.Many situations require special designs; modifications ofstandard filter dimensions are accommodated easily.

OSI Biotube Effluent Filters areavailable in several diameters,suitable, suitable for a varietyof applications.8” and 4” models shown

Pure PerformanceThe OSI Biotube Effluent filter is the most advanced in theindustry, engineered to provide maximum protection for yourseptic system

Biotube Effluent Filters

Call Milan Engineered Systems for yourcustom filter needs!

3

Page 4: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Septic Tank Effluent Pumping Systems & Related Products

Orenco’s Septic Tank Effluent

Pumping System (STEP System) is used for

pumping effluent from single or double

compartment septic tanks and dosing tanks.

Patented Biotube® vault technology filters

out solids so that only liquid from the “clear

zone” between the tank’s scum and sludge

layer is pumped. This reduces biological

loading and clogging of downstream

components. All systems are pre-assembled

with corrosion resistant, durable

components, ensuring reliability.

Septic Tank Effluent Pump System

S.T.E.P. Package

• Riser Assembly• Lid• Riser• Splice Box• Adapter• Bolts• Epoxy

• Biotube®

Screened Pump Vault• Pump, Piping Assembly• Control, Float Assembly• 5 Year Warranty

High headPump System

Low headPump System

Septic Tankor

Pump Tank

Septic Tankor

Pump Tank

4

Page 5: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Tank Width Tank Length4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10

5 12.46 14.02 15.58 17.13 18.69 20.25 21.81 23.37 24.92 26.48 28.04 29.60 31.155.25 13.08 14.72 16.36 18.99 19.63 21.26 22.90 24.53 26.17 27.81 29.44 31.08 32.715.5 13.71 15.42 17.13 18.85 20.56 22.28 23.99 25.70 27.42 29.13 30.84 32.56 34.275.75 14.33 16.12 18.91 19.71 21.50 23.29 25.08 26.87 28.66 30.45 32.24 34.04 35.83

6 14.95 16.82 18.69 20.56 22.43 24.30 26.17 28.04 29.91 31.78 33.65 35.52 37.396.25 15.58 17.52 19.47 21.42 23.37 25.31 27.26 29.21 31.15 33.10 35.05 37.00 38.946.5 16.20 18.23 20.25 22.28 24.30 26.33 28.35 30.38 32.40 34.43 36.45 38.48 40.506.75 16.82 18.93 21.03 23.13 25.23 27.34 29.44 31.54 33.65 35.75 37.85 39.96 42.06

7 17.45 19.63 21.81 23.99 26.17 28.35 30.53 32.71 34.89 37.07 39.25 41.44 43.627.25 18.07 20.33 22.59 24.85 27.10 29.36 31.62 33.88 36.14 38.40 40.66 42.91 45.177.5 18.69 21.03 23.37 25.70 28.04 30.38 32.71 35.05 37.39 39.72 42.05 44.39 46.737.75 19.32 21.73 24.14 26.56 28.97 31.39 33.80 36.22 38.63 41.05 43.46 45.87 48.29

8 19.94 22.43 24.92 27.42 29.91 32.40 34.89 37.39 39.88 42.37 44.86 47.35 49.85

Septic Tank Draw Down / Gallons per Inch

Inside Dimensions

OSI Pump BasinsOrenco’s Pump Basins are used as secondary pump chambers and lift stations in septic

systems. Constructed of PVC pipe with fiberglass base and lid. A 4” inlet elbow and holes toaccommodate splice boxes and discharge piping are located and sized for each application.Available in 18”, 24” and 30” diameters in standard 6” length increments. Custom lengths available in1” increments.

Liquid Capacities24” Dia. — 1.88 Gal. /

Inch30” Dia. — 2.96 Gal. /

Inch

Pump Basin

5

Orifice 2’ Head 3’ Head 4’ Head 5’ Head 6’ Head 7’ Head 8’ HeadDiameter

1/8” 0.273 .335 0.386 0.432 0.473 0.511 0.5475/32” 0.427 0.523 0.604 0.675 0.740 0.799 0.8543/16” 0.615 0.753 0.870 0.643 1.066 1.151 1.2317/32” 0.837 1.026 1.184 1.324 1.451 1.567 1.6751/4” 1.094 1.340 1.548 1.730 1.895 2.047 2.188

Flow in GPM for Various Size Orifices

Page 6: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

3885 Submersible Effluent Pump (3/4” Solids)Order No. HP PH Volts DisWE0511H 1/2 1 115 2”WE0512H 1/2 1 230 2”WE0511HH 1/2 1 115 2”WE0512HH 1/2 1 230 2”WE0712H 3/4 1 230 2”WE1012H 1 1 230 2”WE1512H 1 1/2 1 230 2”WE1512HH 1 1/2 1 230 2”

3871 Submersible Effluent Pump (3/4” Solids)Order No. HP PH Volts DisEP0411A 4/10 1 115 1 1/2”EP0511A 1/2 1 115 1 1/2"

Founded in 1848 in Seneca Falls NY, Goulds Pumps,Inc. has been a leader in the manufacture and marketing ofhigh quality pumps for diverse industries.

The company has offices, warehouses , andmanufacturing facilities worldwide, conducting business inover 100 countries in the Americas, Europe, Africa, themiddle East and Asia Pacific.

The company operates in two distinct market sectors:Industrial and Water technologies. In the United States,industrial and water technologies products aremanufactured in several locations and sold worldwide.Double suction, multi stage, slurry and process pumps,turbine, line shaft, submersible, jet, sump and sewageproducts, and centrifugal products are produced in facilitiesin New York, Pennsylvania, California, and Texas. Anadvance R&D facility supports these product offerings.Foundries operate in three US locations. A network of PRO(pump, repair & Overhaul) service centers can repair andrebuild any brand of pump. Goulds Pumps Europe is

About Goulds...Headquartered in London, England and has sales,manufacturing, warehouse, service and distributingfacilities throughout the British Isles, Europe, Africa andthe Middle East. Stainless steel products are producedat high tech production and R&D facilities at LowaraPumps in Italy.

3871 3885

6

Page 7: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

3887 Sewage Pump (2” Solids)Order No. HP PH Volts Dis.WS0511BF 1/2 1 115 2”WS0512BF 1/2 1 115 2”WS0712BF 3/4 1 230 2”WS1012BF 1 1 230 2”WS1512BHF 1 1/2 1 230 2”WS2012BHF 2 1 230 2”

3888D3, D4 Sewage Pump (3” Solids)Order No. HP PH Volts Dis.WS1512D3, D4 1 1/2 1 230 3”WS2012D3, D4 2 1 230 3”WS3012D3, D4 3 1 230 3”WS5012D3, D4 5 1 230 3”

Additional Voltage, Phase, ModelsAvailable

Additional Models Available - Contact Milan Engineered Systems for your specific needs

3872 Sewage Pump (2” Solids)Order No. HP PH Volts Dis.WW0511 1/2 1 115 2”

3886 Sewage Pump (2” Solids)Order No. HP PH Volts Dis.WS0511B 1/2 1 115 2”WS0512B 1/2 1 230 2”Economy Sewage Pump

3887 3888

3872 3886

7

Page 8: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Where Innovation MeetsTradition

Founded in 1870, Myers offers product lines

which are supported by a long-standing reputation

of quality and reliability.

More than 600 employees, dedicated to quality

and service, utilize state-of-the-art technology and

process to make Myers a world-class

manufacturer. Many of these people are second

and third generation Myers Employees, assuring

that high levels of experience, care and

craftsmanship go into each pump we build.

ME40 Effluent / Drain Water PumpOrder No. HP PH Volts Config DischargeME40AC-11 4/10 1 115 Auto 1 1/2”ME40M-11 4/10 1 115 Manual 1 1/2”ME40P-1 4/10 1 115 Auto Pig 1 1/2

ME Series Effluent PumpOrder No. HP PH Volts Max Sol. DischargeME50S-11 1/2 1 115 3/4” 2”ME50S-21 1/2 1 230 3/4” 2”ME75S-21 3/4 1 200 3/4” 2”ME100S-21 1 1 230 3/4” 2”ME150S-21 1 1/2 1 230 3/4” 2”

SSM33 Submersible / Effluent PumpOrder No. HP PH Volts Config DischargeSSM33P-1 1/3 1 115 Auto 1 1/2”

SSM33

Performance Curve

ME

Performance Curve

ME40Performance Curve

8

Page 9: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

SRM4 Sewage PumpOrder No. HP PH Volts Max Sol. DischargeSRM4P-1 4/10 1 115 2” 2”SRM4PC-2 4/10 1 230 2” 2”

CMV5 Sewage PumpOrder No. HP PH Volts Max Sol. DischargeCMV5A-11 1/2 1 115 2” 2”

MW Series Single Seal Sewage PumpOrder No. HP PH Volts Max Sol. DischargeMWH50-21 1/2 1 230 2” 2”MW100-21 1 1 230 2” 2”MW150-21 1 1/2 1 230 2” 2”MW200-21 2 1 230 2” 2”

MW50 Sewage PumpOrder No. HP PH Volts Max Sol. DischargeMW50-11 1/2 1 115 2” 2”MW50-21 1/2 1 230 2” 2”

MW50

Performance Curve Performance Curve

MW

CMV5Performance Curve

SRM4Performance Curve

Motor Rating Copper Wire Size (1)

Volts HP 14 12 10 8 6 4 2 0 00

1/3 130 210 340 540 840 1300 1960 2810 35401/2 100 160 250 390 620 960 1460 2160 26301/3 550 880 1390 2190 3400 5250 7960 117701/2 400 650 1020 1610 2510 3880 5880 87203/4 300 480 760 1200 1870 2890 4370 6470 78701 250 400 630 990 1540 2380 3610 5360 6520

1.5 190 310 480 770 1200 1870 2850 4280 52402 150 250 390 620 970 1530 2360 3620 44803 120 190 300 470 750 1190 1850 2890 36105 0 110 180 280 450 710 1110 1740 2170

115

230

Single Phase Motor Maximum Cable Length(motor to service enterance) (2)

9

Page 10: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Controls and FloatsSimplex Control Panels, “S” SeriesSimplex Control Panels can be used for pressure sewer (STEP) systems, onsite treatment systems,and pump control into conventional gravity or pressurized drainfields. “S” series pump controlpanels are the best choice for a simplex pump and alarm system. These panels include a motorcontractor, which increases system life by reducing the load requirements on the float switches.“S” series panels also allow options such as a programmable timer or use of larger horsepowerpumps.

MVP Simplex Control Panels, “MVP-S” SeriesMVP Simplex Control Panels are especialy suited for timed dosing in single pump systems. AllMVP’s include an easy-to-use, programmable logic unit that incorporates many timing and logicfunctions, such as multiple timing intervals to adjust for changing flow conditions. “MVP-S” panelsoffer several functions as standard, including the sbility to use one float switch type for all functions,elapsed time meters, and digital indication of float switch status.

Sand Filter Control Panels, “SSF” SeriesSand Filter Control Panels can be used to control two pumps in a sand filter treatment system.“SSF” control panels use motor contractors to activate the pumps, (instead of float switches, as inASF panels). This allows more flexibility in drawdowns and allows for more options. Interlockedcontrols prevent the septic tank pump from running if a high level condition occures in the sandfilter. “SSF” series panels also allow for options such as a programmable timer for use of largerhorsepower pumps.

Duplex Control Panels, “DAX” SeriesDuplex Control Panels can be used in pressure sewer and onsite treatment systems that requirethe use of two alternating pumps. The pair of pumps can be wired for both “lead” and “lag”operation; a built-in alternating relay switches the “lead” and “lag” positions each pump cycle.

Float Switch AssembliesModel Signal Drawdown Milan Code

MFA N.O. 1” SEW20510MFB N.O. 4” SEW20530MFT N.C. 1” SEW20554MFG N.C. 4” SEW20552

Simplex Dosing Panel• Two Year Warranty • NEMA 4X enclosure • Alarm Beacon, horn (85db)test/normal/silence switch • Control/alarm fuse • UL Approved • Large, easy-to-use terminalblocks • Locking latch • Event counter • 120VAC control/alarm circuit • HOA (hand/off/auto)switch • Circuit breaker pump protection • Magnetic motor contactor • Rated up to 20FLA (fullload amps)

Model Floats MFG Part No. Milan No.MES-2 Dose Panel 2 CP208 SEW10015MES-3 Dose Panel 3 CP208E SEW10020

Prod No. HP Volt Milan No.15PMD1WP 1/2 115 SEW1008015PMD2WP 1 230 SEW10085

Pumpmaster®

Prod No. HP Volt Milan No.15PMPD1WP 3/4 115 SEW1010015PMPD2WP 2 230 SEW10105

Pumpmaster Plus®

Prod No. HP Volt Milan No.15DFD1WP 1 115 SEW1012015DFD2WP 2 230 SEW10125

Double Float

Prod No. Ft Volt Milan No.15PPCNO 30 115 SEW10139

Sensor FloatProd No. Milan No.Cable Weight SEW10190

Cable Weight

10

Page 11: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Pump Accessories

Guide rails

Pump Basins

Access Doors

Valves

Model Dimensions Capacity LidsSF22A 18X24 22.5 Gallons SF44SF30 18X30 30 Gallons SF114SF24X36 24X36 72 Gallons SF24 SplitSF30X36 30X36 110 Gallons JC30DF36X36M 36X36 157.5 Gallons JC36DI

Type: APS (single leaf)Loading: Pedestrian 150lbs. / 300lbs.Frame: Angle non-watertight / watertightMaterial: Aluminum; Steel;

Stainless Steel

Type: APD (double leaf)Loading: Pedestrian 150lbs. / 300lbs.Frame: Angle non-watertight / watertightMaterial: Aluminum; Steel;

Stainless Steel

24x2424x3024x36

30x3030x3830x48

36x3636x4842x42

Sizes

30x4830x5436x48

Sizes36x6042x4848x48

48x5448x7260x60

D.

A.

C.

D. Ball Check Valve (Cast Iron threaded)Size Code

1 1/4” SEW130251 1/2” SEW13030

2” SEW13035

C. Swing Check Valve (compression)Size Code

1 1/4” SEW130051 1/2” SEW13010

2” SEW130153” SEW13020

B. Swing Check Valve (slip x slip)Size Code1” SEW22240

1 1/4” SEW222501 1/2” SEW22260

2” SEW22270

B.

Economy Guide Rail

1 1/4” SPDS5 (1 1/4” Brass) 3/4” Guide Rail*1 1/2” SPDS6 (1 1/2” Brass) 3/4” Guide Rail*2” SPDS8 (2” Brass) 3/4” Guide Rail*3” SPDS360B (3” Brass) 1 1/4” Guide Rail*

*Not Supplied

SGR125-96 (1 1/4” System) Stainless*SGR200-96 (2” System) Stainless*

*Complete

“EZ-Out”

1 1/4” System1 1/2” System

2” System3” System

Priced Per System

A. Ball Valve (slip x slip)

Size Code3/4” VAL023061” VAL02308

1 1/4” VAL023101 1/2” VAL02512

2” VAL023163” VAL02318

A. Ball Valve (threaded)Size Code3/4” VAL0258071” VAL25812

1 1/4” VAL2581211

Page 12: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Tank Alert ® XTThe Tank Alert XTalarm can serve asa high or low level

alarm.

Type 3R enclosureIndoor/Outdoor

use

SEW10144

Duplex Float Arrangements

Fig. 5 Fig. 6 Fig. 7

Three Float(Pump & Alarm)

Four Float(Pump & Alarm)

Five Float(Pump & Alarm)

LAG Pump On + Alarm

Lead Pump On

Off

Alarm

Lag Pump On

Lead Pump On

Off

Alarm

Lag Pump On

Lead Pump On

Off

Redundant Off

Simplex Float Arrangements

Fig. 1 Fig. 2 Fig. 3 Fig. 4

One Float(Pump or Alarm)

Two Float(Pump Differential)

Two Float(Pump & Alarm)

Three Float(Pump Differential & Alarm)

Alarms

Floats

12

Nominal 90o 45o Tee Tee Swing GatePipe Dia. Elbow Elbow (Thru-Flow) (Branch Flow) Check Valve Valve (open)

1.25” 3.5 1.8 2.3 6.9 11.5 .9

1.5” 4.0 2.2 2.7 8.1 13.4 1.12” 5.2 2.8 3.5 10.3 17.2 1.4

2.5” 6.2 3.3 4.1 12.3 20.6 1.73” 7.7 4.1 5.1 15.3 25.5 2.0

Friction Head Losses for Fittings (equivalent feet of piping)

Tank Alert ® 1The Tank Alert 1

alarm can serve asa high or low level

alarm.

NEMA 1 enclosureIndoor use

SEW10145

Page 13: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Valves

The Bull Run® Valveis designed to split flows to septic fields or systems. The Bull Run Valve is available in 4" Sch 40 PVC.and is suitable wherever septic disposal systems are used - in commercial, industrial and residentialapplications.

Divert Paddle ValveRecover that failed drainfieldWhen dual drainfields are constructed from the onset and alternated periodically, the life span of thetwo will be greater than twice that of two drainfields used to points of failure consecutively.Divert Paddle Valve SEW13070

4” Bull Run Valve SEW13065

Flushing Valve cleanout and enclosure allows easy access for maintenance oflaterals and monitoring of system. PVC Sweep Ell, Ball valve, and Valve Box.Flushing Valve available in 3/4”-2” Valve Enclosure available in 7” & 10”

Flushing Valve

Pressure Loss - 4 Outlet ValveFlow (GPM) 10 20 30 40PSI Loss 2.0 3.0 4.5 6.4

Pressure Loss - 6 Outlet ValveFlow (GPM 10 20 30PSI Loss 2.0 4.5 7.5

Pressure Rating25-75 PSI4 Outlet Models have interchangeable Camsfor 2 - 4 Zone Operation. 4402 - 44046 Outlet Models have interchangeable Camsfor 2 - 6 Zone Operation. 4602 - 4606

4000Pressure Loss - 4 Outlet ValveFlow (GPM) 20 40 60 80 100PSI Loss 2.5 3.5 5.0 7.5 10.0

Pressure Loss - 6 Outlet ValveFlow (GPM 20 40 60 80 100PSI Loss 3.0 4.0 6.0 9.0 11.0

Pressure Rating25-75 PSI4 Outlet Models have interchangeable Cams for 2 - 4Zone Operation. 6402 - 64046 Outlet Models have interchangeable Cams for 2 - 6Zone Operation. 6602 - 6606

6000

Orifice ShieldOrifice Shields are used in a pressurized distribution system to protect the orificesfrom backfill debris that might cause orifice blockage.Available in 3/4”, 1”, 1 1/4”, 1 1/2”, 2”

This proven design is suited for a variety of applications featuring multiple endconnector options.Available in 1/2”-4” sizes

PVC Gate Valves (Pressure Rated)

Pvc sliding Gates Valves are used as an inexpensive valve for quick shut off.Constructed with PVC and 416 stainless steel, with slip connection.Available in 4”, S x S (slip on both ends)

PVC Gate Valves

13

Specialty NonStock Valves AvailableConsult with Milan Engineered Systems on

application and availability

Page 14: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Part Order No.9HD2 SEW16095

DistributionBox

Disposal Field AccessoriesDrop Box

Size Order No.54”x100’ SEW2175036" X 300' SEW2175236" X 1500' SEW2175472" X 300' SEW2175672" X 1500' SEW21758Red RosinPaper 20# SEW21774

Filter Fabric

A permeable membranethat prevents migration ofmedia from one layer to

another.

Part Drop Order No.DB02 w/ lid 2” SEW16000DB04 w/ lid 4” SEW16001DB06 w/ lid 6” SEW16002

11" x 11" x 15 1/2" TallB1 Riser 6” Tall SEW16003

11" x 11" x 6" Tall

10” Valve Box

10” Round Valve BoxSEW16210

7” Valve Box

7” Round Valve BoxSEW16200

ZoellerDistribution BoxPart Order No.TRU FLOW SEW16150

Minimum Solids Flow (2’/sec.)

Pipe Size Minimum GPM

1 1/4” 91 1/2” 13

2” 213” 464” 806” 1808” 32510” 500

Fluid Volume in Pipe

Pipe Size Volume

1 1/4” .061 1/2” .09

2” .163” .364” .6256” 1.48” 2.610” 4.07

GPM Plastic Steel* Plastic Steel* Plastic Steel* Plastic Steel* Plastic Steel*

4 .34 .356 .71 .72 .33 .348 1.19 1.20 .56 .5710 1.78 1.74 .83 .8512 2.48 2.45 1.16 1.18 .34 .3514 3.29 3.24 1.54 1.51 .45 .4616 4.21 4.15 1.97 1.93 .58 .5918 5.25 5.17 2.41 2.40 .72 .7320 6.42 6.31 2.96 2.92 .88 .8825 10.39 9.61 4.80 4.80 1.38 1.3930 13.6 13.0 6.27 6.23 1.81 1.82 .75 .7735 19.2 18.2 8.82 8.82 2.40 2.40 1.01 .9940 10.70 10.80 3.12 3.10 1.28 1.3045 14.0 14.0 3.8 3.8 1.5 1.6 .55 .5650 16.5 16.5 4.7 4.7 1.9 1.9 .66 .6860 6.5 6.6 2.7 2.7 .94 .9170 8.6 8.8 3.7 3.6 1.2 1.280 11.1 11.4 4.7 4.6 1.6 1.690 13.8 14.3 5.8 5.8 2.0 2.0100 16.8 17.5 7.1 7.1 2.4 2.4125 10.9 10.9 3.7 3.6150 15.9 15.9 5.2 5.1175 6.9 6.9

1.25” Dia. 1.5” 2” 2.5” 3”

Friction Head Losses for Pipe — Per 100 Feet of Piping

14

Page 15: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

15

Polyeptic TanksPoly Septic Tanks

Zabel Effluent Filters

Orenco Effluent Filters

Single Compartment

300 Gal SEW96000500 Gal SEW96020

1000 Gal SEW960402 Compartment

1000 Gal SEW96050• Additional Sizes Available• 6” & 12” Risers in Stock

A-1801 SEW15005A-100 SEW15010A-300 SEW15015

4”x36” BIOTUBE SEW221584”X44” BIOTUBE SEW221608”X48” BIOTUBE SEW22180

12”X54” BIOTUBE SEW2218515”X54” BIOTUBE SEW22187

N12

N12 24” Corrigated Smooth Interior Pipe• Great for Septic Tank Risers• Storm Water Management• Durable - Resists Salts, Abrasive

Chemicals, & Aggresive Chemicals

Coiled Plastic Drain Pipe

4” x 150’ Solid SEW945104” x 150’ Slotted SEW945004” x 150’ Slotted w/Sock SEW94505

Coiled Plastic Fittings

4” Corrugated Plug SEW945214” Corrugated Coupling SEW945154” Corrugated Wye SEW945204” Corrugated Tee SEW945224” Corrugated 90° Ell SEW94526

Septic Tanks and Accessories

Corrugated Drainage Pipe

Fractional Equivalents

Page 16: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Size Part No..75” PVC120201” PVC120301.25” PVC120401.5” PVC120502” PVC120603” PVC120804” PVC12090

Size Part No..75” PVC060151” PVC060201.25” PVC060251.5” PVC060302” PVC060354” PVC06065

Size Part No..75” PVC050151” PVC050201.25” PVC050251.5” PVC050302” PVC050353” PVC050454” PVC05047

SocketFIPT

PVC Pipe SDR 21 Class 200PVC 00675 0.75” x 20’ Belled endPVC 00680 1” x 20’PVC 00720 1.25” x 20’PVC 00735 1.5” x 20’PVC 00738 2” x 20’

PVC Pipe Schedule 40 10’ lengthPVC 00755 1.5” x 10’PVC 00760 2” x 10’PVC 00765 3” x 10’PVC 00770 4” x 10’

PVC Pipe Schedule 40 20’ lengthPVC 00200 0.75” x 20’PVC 00210 1” x 20’PVC 00215 1.25” x 20’PVC 00225 1.5” x 20’PVC 00252 2” x 20’PVC 00330 3” x 20’PVC 00420 4” x 20’

PVC Pipe Schedule 80 20’ lengthPVD 00010 1.25” x 20’PVD 00012 1.5” x 20’PVD 00016 2” x 20’PVD 00024 3” x 20’PVD 00032 4” x 20’

PVC Glue & PVC PrimerPVC Glue & PVC PrimerPVC Glue & PVC PrimerPVC Glue & PVC PrimerPVC Glue & PVC PrimerPVC 01005 1 Pint Glue Rain & Shine BluePVC 01010 1 Qt Glue Rain & Shine BluePVC 01017 1 Pint Glue All Weather ClearPVC 01018 1 Qt Glue All Weather Clear

PVC 01025 1 Pint Primer ClearPVC 01030 1 Qt Primer ClearPVC 01055 1 Pint Primer PurplePVC 01060 1 Qt Primer Purple

PVC Pipe and Fittings (Pressure)

Cap

Tee

PVC Pipe & Acc.

Size Part No..75” PVC118951” PVC119001.25” PVC119021.5” PVC119052” PVC11920

PlugSize Part No.75” PVC070151” PVC070201.25” PVC070251.5” PVC070302” PVC070353” PVC070454” PVC07050

CouplingSize Part No..75” PVC015021” PVC015051.25” PVC015151.5” PVC015202” PVC015253” PVC01535

MaleAdapter

Size Part No.1” PVC075081.25” PVC075101.5” PVC075122” PVC075163” PVC075244” PVC07532

CrossSize Part No..75” PVC020051” PVC020101.25” PVC020151.5” PVC020202” PVC020253” PVC020354” PVC02040

Female Adapter

Size Part No..75” PVC080151” PVC080201.25” PVC080251.5” PVC080302” PVC080353” PVC080454” PVC08050

Elbow 90°

Size Part No..75” PVC115051” PVC115101.25” PVC115151.5” PVC115202” PVC115253” PVC115354” PVC11540

Elbow 45°

Size Part No.1” x .75” PVC030301.25” x .75” PVC030501.25” x 1” PVC030601.5” x .75” PVC030801.5” x 1” PVC030901.5” x 1.25” PVC031002” x .75” PVC031102” x 1” PVC031202” x 1.25” PVC031302” x 1.5” PVC031403” x 1” PVC032053” x 1.25” PVC032103” x 1.5” PVC032204” x 2” PVC032804” x 3” PVC03300

Bushing

Size Part No..75” PVC160451” PVC160501.25” PVC160551.5” PVC160602” PVC16065

Union

16

(slip x slip)

Page 17: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Adapter(cleanout) (spigitxfpt)

SEW82120 4”

Sanitary Tee(HxHxH)

SEW82628 1 1/2”SEW82636 2”SEW82646 3”SEW82654 4”SEW82660 6”

90° Ell (HxH)SEW82257 1 1/2”SEW82259 2”SEW82261 3”SEW82263 4”SEW82267 6”

Coupling (HxH)SEW82143 1 1/2”SEW82145 2”SEW82149 3”SEW82155 4”SEW82161 6”

Plug (MPT)SEW83410 4”SEW83412 6”

45° Ell (HxH)SEW82472 1 1/2”SEW82474 2”SEW82476 3”SEW82478 4”SEW82480 6”

Female Adapter(FPTxS)

SEW82102 2”SEW82104 3”SEW82106 4”SEW82108 6”

22 1/2° Ell (HxH)SEW82503 1 1/2”SEW82505 2”SEW82507 3”SEW82509 4”

Wye (HxHxH)SEW83222 4”

Sanitary Tee (HxHxH)SEW94304 4”

Coupling (HxH)SEW94129 4”

90° Ell (HxH)SEW94195 4”

45° (HxH)SEW94207 4”

22 1/2° (HxH)SEW94227 4” Cap (Slip)

SEW94345 4”

PVC DWVPVC Pipe and Fittings (DWV and S&D)

PIPESch40 - DWV Dual Rated

1 1/2” x 10’ Plain End SEW80000C2” x 10’ Plain End SEW80002C3” x 10’ Plain End SEW80004C4” x 10’ Plain End SEW80006C4” x 10’ Bell End SEW80008C4” x 10’ Cell Core BEll SEW80010C4” x 10’ SDR 35 SEW90000

Sewer & Drain4” x 10’ Cresline Solid SEW92015C4” x 10’ Cresline Perf. SEW92010C4” x 10’ ADS Solid SEW920254” x 10’ ADS Perf. SEW92020

Cross (HxHxHxH)SEW94195 4”

Sewer & Drain

17

Plastic to PlasticSize Milan No.2 x 2 F500064 x 3 F500244 x 4 F500106 x 4 F500286 x 6 F50014

Clay to CI/PlasticSize Milan No.4 x 4 F50047

Fernco Flexible Couplings

Page 18: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Tank Access RisersOrenco’s fiberglass lids provide a secure covering for access risers, supporting a 2,500 lb.wheel load. Lids are molded with an attractive green finish and a textured non-skid topsurface. Note: Lids are not rated for vehicular traffic.

Diameter: 18”, 21”, 24”, 30” 2” Insulation Available for Lids

Risers provide access to septic tank openings and can be cast into the tops of concretetanks, bonded in place, or bolted down using a Riser Tank Adapter.

Diameter: 18”, 21”, 24”, 30” Depth: 2’ thru 13’ Avail (one foot incriments)

Orenco’s Tank Adapters are used to provide a structural, watertight method of installing anaccess riser over a tank opening. Adapters can either be cast into the top of a concrete tank,bonded to the top of a fiberglass tank, or fastened with a bolt-down kit.Adapter Type Tank Outlet Type and Size Riser DiameterPRTA24 Up to 24” round or 15” square 24”RRFTA Up to 21” round or 24” square 21” or 24”RRFTA30 Up to 24” round or 30” square 30”FRTA30 Up to 30” round or 20” square 30”

A Grade Ring is used to extend the height of an existing riser, pump basin, or sand filterpump basin.Diameter: 18”, 21”, 24”, 30”

Splice Boxes are used to safely house spliced wire connections. Boxes are available with 1 to6 watertight cord grips.

Pipe Grommets are used to provide a watertight seal at piping penetrations. All grommetsconform to standard IPS sizes.

RRFTABDKIT Bolt-Down KitBolt-Down Kit includes butyl tape and concrete anchors.

RUBDKIT Bolt-Down KitBolt-Down Kit includes three concrete anchors and three stainless steel hold-down straps toattach Ultra-Rib risers to top of concrete tank.

Epoxy (adhesive)ADH100 Adhesive

MA320 Adhesive: 2-Component SEW21320

ADH10 Adhesive: 2-Component Pint: SEW21300 Quart:SEW21310

Splice Box

Bolt Down Kits

Adapters

Risers

Lids

Grade Ring Inserts

Grommets

18

G1 1” SEW21330G125 1 1/4” SEW21340G150 1 1/2” SEW21350

G2 2” SEW21360G3 3” SEW21370G4 4” SEW21380

Page 19: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Product Benefits• Easy to install with no messy cleanup.• Absolutely no stone required.• Lightweight chambers can be hand carried to trench.• Fast installation saves time and money.• Infiltrator chambers have a 12-year success

rate of 99.5%.• Greater infiltrative capacity means added protection

and peace of mind.

Equalizer 36 Nominal Chamber SpecificationsChamber Size (W x L x H) 22" x 101" x 13½"

The Equalizer® 36Chamber

Equalizer 36 Nominal Chamber SpecificationsChamber Size (W x L x H) 34" x 75" x 12"

The StandardInfiltrator® Chamber

19

AdvanTexTM

TreatmentSystems.

Our patented AdvanTexTM

Treatment System works just likea recirculating packed bed filter –a proven technology. But theAdvanTexTM Treatment Systemused a highly efficient, non-woven textile material, instead ofsand or gravel, for the treatmentmedia.

AdvanTexTM textile treatmentsystems produce effluent thatexceeds “secondary” treatmentstandards. And because textilecan handle much higher loadingrates than sand or gravel media, textile filters are very compact units. So they cost less for single-family installations, require significantly less land area, and are easier to install than other packedbed filters.

Page 20: Wastewater Specialty Catalog 2002-2003 - Conrads … · Indian River 6031 S. Straits Highway 1•231•238•9200 1•231 ... of the transport line size and associated ... Septic

Pumps• Orenco• Myers• Goulds• Sta-Rite

Wastewater Treatment• Orenco• Bio Microbics• NCS

Electrical Controls• Orenco• SJE Rhombus

Milan Engineered Systems is known for the company we keep . . .

. . . and the products we carry

Contact Milan Engineered Systems for all your Wastewater Needs

Specialty Equipment• Infiltrator Leach Fields• Basins• Distribution Boxes• Guide Rail Systems• Automatic Siphons• Access Doors• Effluent Filters

Valves• Gate• Ball• Paddle• Hydrotek• Bull Run• Swing Check• Ball Check

PVC Pipe & Fittings• Sch 40 Pressure Pipe & Fittings• DWV Pipe & Fittings• Sewer & Drain Pipe & Fittings

Complete Systems• Effluent Pump Systems• Sewage Pump Systems• Grinder Systems

P.O. Box 309Mt. Pleasant, MI 48804-0309Tele: 989•773•9100Fax: 989•772•3415