washing stand naoclean manual · safe for human naoclean guarantees both the safety of users and a...

24
Strong Disinfecting·Deodorizing Power Prevent Disease such as Food poisoning Safe to Human Body Harmless and Environment Friendly Product Almost No Residual Chlorine Please read the manual before installing or using the device. Sterilizing, deodorizing washing stand NaOClean Manual www.naoclean.com

Upload: others

Post on 17-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 1

www.naoclean.com

Strong Disinfecting·Deodorizing PowerPrevent Disease such as Food poisoning

Safe to Human BodyHarmless and Environment Friendly Product

Almost No Residual Chlorine

Please read the manual before installing or using the device.

Sterilizing, deodorizing washing stand NaOClean

Manual

www.naoclean.com

Page 2: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical
Page 3: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 3

www.naoclean.com

CONTENTS

4 7 18 19 page

1. About product

- Components - Specification & Features

2. Using the device

- How to operate - Applications & Use- Installation- After using

3. Making saline solution

4. Inspection

- Safety precaution- Check the saline solution- Check the error - Electrode replacement & Block diagram

Page 4: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 4

www.naoclean.com

High qualitystainless disinfecting sink

Model: DES-WS850

Lock handle

Body

Disinfectant outlet

Saline checking lamp

Footstep switch(ON/OFF)

Water supply valve

Saline solutionsupply hose

Internal control panel

Saline tank

Water level controller

Internalcontrolpanel

1. About product > Components / Specification & Features

Internal brine tank

Page 5: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 5

www.naoclean.com

1. About product > Components / Specification & Features

Internal control panel

START/STOP (on/off)This button is generating the disinfectant.You have to use the disinfectant more than 15 seconds because the normal disinfectant is supplied after 10 seconds. Also, you can use with footstep switch for same functions. (After using, you have to step on the footstep switch once again to stop the flow. If not, the device will be stopped automatically after 40 seconds.)

POWER

WATER CHECKSALINE CHECKCLEANINGCONTINUOUS 10MIN

LOWPOWER LEVEL MIDIUM HIGH

20MIN

Disinfectant Generator

START

STOPTIME CLEAN

ING

O N

OFFPOWER

Power (on/off)

When you connect the power plug, power is switched on.

Cleaning

When you press the cleaning button, water is supplied for 2 minutes and cleans inside the device automatically.

When cleaning, any buttons (except on the power and start/stop) button are not operated.

(It is recommended to clean twice a month.)

Saline checking lamp

When the saline solution is not supplied normally, the lamp will blink with a buzzer will alert.

Water checking lamp

When the water is not working normally, the lamp will blink with a buzzer will alert.

Display

Normal: Display the number.Error: Display the ‘Er’.

Time

When the device is operating, you can choose the time ‘10min’, ‘20min’

or ‘continuation’. After that time, it is turned off automatically.

Page 6: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 6

Specification Features

Model

Dimension

Rated voltage

Weight

Generating

Electrolysis method

pH

Active chlorine

Additive

Using condition

Amount of salt per operation

Materials

DES-WS850

W500 X D500 X H850mm

AC 220V, 60Hz / 400W

About 35kg

About 3~4L/min

Without membrane

7.0~7.5pH

About 70~100ppm

Salt (Salinity more than 88%)

Surrounding temp 5~40℃, water temp 5~30℃

2kg

A strong disinfecting & deodorizing powerNaoClean generates one of the three most powerful disinfecting wa-ters. The disinfecting water can fully sterilize bacteria and deodor-ize in a short time at lower concentrations than traditional chemical disinfectants.

Safe for humanNaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical disinfectants. It leaves almost no residual chlorine, thanks to a quick dissolution of active chlorine.

Zero pollutionDischarging untreated electrolyzed-disinfecting-water directly into the sewage system will not damage the environment or the system. Nor is it a violation of any sewerage acts. NaOClean generates safe and clean electrolyzed disinfecting water without producing a toxic smells and ensures good working conditions.

Cost effectiveThe cost of using NaoClean is significantly lower than conventional disinfectants. Since it effectively kills a wide variety of bacteria, it can replace expensive chemicals. Workers may enjoy shorter working hours and procedures by using NaOClean.

1. About product > Components / Specification & Features

ball valve(1/2)

nipple(1/2)

P/T nipple(1/2)

T-connector

Page 7: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 7

www.naoclean.com

1.

2.

3.

4.

Please plug in the power cord and check a short beep sound. (It will be in standby mode.)

Step on the footstep switch to generate the disinfectant. You have to use the disinfectant more than 15 seconds because the normal

disinfectant is supplied after 10 seconds.

You can sterilize and deodorize any object and place without any harmful effects.

After using, you have to step on the footstep switch once again to stop the device. If not, the device will be stopped automatically after

40 seconds. If you want more after 40 seconds, just step on the footstep switch once again.

Operating sequence

2. Using product > How to operate / Applications & Use / Installation / After using

41

32

Page 8: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 8

It sterilizes and deodorizes a bad smells on your hand and body. It is mainly used in food processing such as fish or meat. You can effectively use this device before & after work.

NaOClean has been shown to be highly effective in disinfecting bacteria such as E.coli, S.aureus, V.parahaemolyticus and S.typhi by washing hand.

It effectively removes bacteria and bad odor from the rotten fish, meat and other foods. Also, it sterilizes dirty knives, cutting board, dishes, spoon, fork, cup and etc.Wash out them with NaOClean wa-ter. If the smells are strong, soak for more than 10 minutes.

(Wash out once with tap water if you are worried about something problems.)

It disinfects dishtowel, working clothes, caps, boots, and removes bad odor such as fishy smell by soaking them for 5~10 minutes in NaOClean water. It is more effective to hand-rub them. (Be cautious as the solution may bleach the colored textiles.)

Provide a pleasant environmentNaOClean maintains clean and sanitary en-vironment in and outdoors. Also, it solves the major health problems in your work places.

Remove the odors and sanitize your toilet, bath, drain and all kinds of sanitary zones.

(Wash out once with tap water if you are worried about something problems.)

Main use

2. Using product > How to operate / Applications & Use / Installation / After using

Page 9: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 9

www.naoclean.com

2. Using product > How to operate / Applications & Use / Installation / After using

Other use

NaOClean reduces underarm and foot odor and help to cure athlete

,s foot. Soak your feet into the NaOClean water

for 5 minutes several days.

NaOClean helps to cure bad breath and mouth ulcer by gargling daily.

Getting rid of a permanent wave smell has been a prob-lem, but NaOClean removes very easily and safely be-cause it has a powerful deodorizing effects without any harmful effects.

NaOClean also disinfects your skin by misting or spray-ing. If your skin has suffered from allergy, atopy, or acne, NaOClean will help you to be improved.

NaOClean helps to clean pet,s fur and remove the bad

smells on your pet. Also, if they defecated, NaOClean solves the odor and bacteria problems.

You can sterilize many kinds of bacteria on the surface of fruit, cucumber, lettuce, sesame leaf, ingredients, process-ing food and seafood. Soak them for 3~5 minutes and then, you can rinse only once, while the drug has to rinse for several times (4~5).

-

-

-

-

-

-

----

※ You have to rinse something after using the disinfecting water. If not, it may have a weak smell of disinfectant.

For personal hygiene in fish and meat processing factories Seafood restaurants Public restroomLivestock and fishery

Recommended applications

Page 10: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 10

Note of caution when installing

1. Do not install this device in the area where ventilation does not function properly, or in oily, smoky, humid, dusty, and water splashing places.

2. Install the device in a flat ground so that the device maintains level and avoids danger of falling.

3. Install the device in a place with surrounding temperature of 5~40℃ and humidity must be less than 95% RH. It must be protected from a freezing trouble.

4. You have to use an ap-proved single socket. Do not use a multi-socket.

※ If a grounded socket is not available, make sure to connect the ground wire to a grounding pole of the floor or grounding connector. (metal pipes)

※ Do not ground the device to a gas pipe or an antenna.

※ Check the device operates normally when the installation completely finished.

Cautions

2. Using product > How to operate / Applications & Use / Installation / After using

If the surrounding temperature drops to below zero degrees, stop using the device. If the device is not used for a long time, press the Cleaning button to clean inside the device (automatically) and completely drain water in the tank.

Page 11: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 11

www.naoclean.com

1. Only use clean water such as tap water that complies with the drinking water regulations.

2. Install Water softer when hard underground water is used, or install a filter to re-move many impurities.

3. Water pressure: more than 1.5kgf/㎠, less than 7.0kgf/㎠

4. Supply adequate amount of water by setting the Water volume control valve.

※If the water supply is inadequate due to low-pressure, the concentration of the disinfectant will be high. So, supply appropriate amount of water.

Water supply specifications Cautions

2. Using product > How to operate / Applications & Use / Installation / After using

Page 12: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 12

Pipe connection method

- Hose standard: Hosiery yarn hose 9X13mm

- Pipe bushing : 1/4, 11mm

- Valve: 1/2

- Pipe T-connector: 1/2

- Tightening band: Stainless band

1. Remove the faucet. (Close the Water pipe before this.)

T-connector

Pipe bushing

Water supply valve

2. Connect the appropriate Water pipe connector.

2. Using product > How to operate / Applications & Use / Installation / After using

3. Reconnect the original faucet.

Page 13: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 13

www.naoclean.com

2. Using product > How to operate / Applications & Use / Installation / After using

Valveconnector

Water supply hose(Hosiery yarn hose 9X13m)

Saline solutionsupply hose

Connection hose for the pump

Stainless band

4. Connect the hose between Water pipe connection nipple and Decom-pression valve at the back.

5. After work, open the Water pipe and Valve.

<Piping materials>

Boll valve (1/2)

T-connector

original

Nipple(1/2)

PT nipple(1/2)

Decompressionvalve

Drain hose

Filter (Options)

1

1

Turn the black-ring. Disassemble the units.Connect the Water supply hose. Water supply hose

Page 14: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 14

2. Using product > How to operate / Applications & Use / Installation / After using

How to assemble faucet

Please loosen the two screws on the back cover which shows on the picture.

please put hose through the faucet body and fasten ④ unit with ⑤ unit.

Please assemble the hose with unit ⑥ and pull the hose from the body so the unit ⑥ can stick to the faucet body (⑤) as shown on the picture.

Please fasten unit ⑦ with faucet body (⑤) and close the back cover and fasten screws.

Please take out the hose from the body, and put the rings and nut in order. (ex. bottom ① -> ② -> ③)

Please place the hose to origin place, and fasten ④ unit with nut (①) from thop of the hose.

4

4

5

67

Please disassemble the faucet as shown on the picture.

24 5

67

3

1

Page 15: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 15

www.naoclean.com

2. Using product > How to operate / Applications & Use / Installation / After using

How to assemble footstep

After installation, please folow the procedure in order on the below.

Please make saline solution following the direction on page 18.

First, step on the footstep switch to generate disinfectant. Open the back cover and adjust the Water volume control valve to make

indicator shows the number range between 25 and 28. (Closing the valve will cause the number increase, openning the valve will casue

the number decrease.)

After finishing the adjustment, please close the back cover and fasten screws.

1.

2.

3.

Please find the footstep switch connector on the bottom side and connect with footstep switch. (Please make sure the wire is con-nected through the hole )

Please fasten three screws with footstep bracket.

Page 16: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 16

Installation for example - Processing line

2. Using product > How to operate / Applications & Use / Installation / After using

Keep the personal hygiene before & after workNaOClean helps to keep the personal hygiene by removing dirt and bacteria before and after work. It is mainly used in fish, meat and food processing plants for washing hand and others. With one movement, you can effectively sterilize all kind of items such as rubber gloves, boots and utensils. Also, it deodorizes fishy and rotten smells effectively.

Page 17: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 17

www.naoclean.com

- You have to rinse the saline solution inside the each component by pressing the Cleaning button twice a month. It prevents the device from corroding and will extend the life of device.- If you don’t use the device for a long time, empty the Saline solution tank and clean it. (Please handle it with care.)

Management after using

2. Using product > How to operate / Applications & Use / Installation / After using

1. Pull the Connecting hose in the tank by hand.2. Loosen the filter and nipple from the hose.3. Clean the filter with tap water.4. After cleaning, insert originally.

How to clean the filter of the Saline solution tank

Filter

Connection

Connectinghose

Fixednipple

Saline solution supply hose

Packing

Pump

Power code

Saline solution control hose

Water levelcontroller Saline solution

supply hose

Check valve prevents flowing backward of the saline solution or disinfectant during the device is operating.

1.2.

3.

Loosen the nut and disassemble the hose.Direct the arrow sign on the check valve to the top and reassemble the hoses.Loosen the nut a little and push the connection hose all the way in. Tightening the nut will firmly hold the hose.

Assemble and disassemble of check valve

※Any foreign substance inside the Saline solution supply hose will damage the function of the check valve. Also, it may result backflow of the solution and damage of parts. ※Please put the Saline solution supply hose into the end, or it will cause leakage.

Connector

Saline solutionsupply hose

Arrow

Nut

Bushing

1.

2.

3.

Connect the hose to the Saline solution tank nipple and the Pump con-nection nipple. ( )Connect the other end of the hose coming from the pump into the Saline solution supply connector. ( )Place the Saline solution control hose into the Saline solution tank. ( )

Pipe of saline solution

1

23

32

1

Page 18: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 18

Cautions before using salt

3. Making saline solution

Please create regulated amount of saline solution.(Refined salt 2kg : Water 20L)

Use only salt with more than 88% salinity that is refined and devoid of any impurities.

Never use table salt processed by adding citric acid or amino acid or roasted salt.

Never use the salt for picking or bay salt that have high amount of impurities.

Making saline solution

You might encounter error although you use the regulated amount of saline solution because it may vary depending on the water quality and temperature. To solve this problem, you have to reduce the amount of salt or add the tap water to lower the salt concentration.

Pour tap water and salt inside the tank and create regulatedamount of saline solution. ※Do not take the tank out entirely because the water line may cause some problems. So, pull out the tank just a little bit and then open the cover.

Stir water to dissolve them completely. (Please be careful of the Water level controller in the tank when you stir them.)

20ℓ 2kgMix ratio

Water Refined salt

Mix ratioIt may vary depending on the water quality and temperature.

Page 19: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 19

www.naoclean.com

Handle with care

1.

2.

3.

4.

5.

6.

7.

8.

9.

Never mix disinfecting water with other disinfectant, abstergent and chemicals.

(But, it can be used with kitchen detergent in some case.)

If you have sensitive skin, wear protective equipment such as rubber gloves.

Do not use disinfectant in the cultivation of plants, animals, fish and shellfish, etc.

Be careful that the solution may bleach the colored textiles.

Be aware of the Corrosion-resistant table on the right side, so please wash it once with

tap water after using.

Be sure to wash the Metal-drainage-pipe with tap water after using the large amount of

disinfectant, because it may cause corrosion.

Chlorine concentration may be degraded by ultraviolet rays, high temperature or long

period of time.

If the saline solution remains in the tank for an extended period of time, it may cause

corrosion.

If you exceed the available chlorine concentration, rinse with tap water after using the dis-

infectant.

※ Do not use the disinfectant in cooking and drinking water.

※Please do not spray on the materials which are listed on the right table marked as

‘weak’.

Cautions

4. Inspection > Cautions / Check the saline solution / Check the error / Electrode replacement & Diagram

An analysis table for corrosion-resistant material

Materials

ABS resin

polyethylene

acrylic

polypropylene

teflon

silicon

epoxy resin

urea resin

Butyl-rubbe, NBR

natural, urethane rubber

titanium, glass, ceramics

stainless steel

plating, copperphosphor bronze

brass

aluminium alloy

steel

Corrosion resistance

Page 20: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 20

Cautions

4. Inspection > Cautions / Check the saline solution / Check the error / Electrode replacement & Diagram

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

Do not use a damaged power cord or a socket.

Do not touch the power plug with a wet hand.

You have to use an approved single socket not a multi-socket.

-The socket may be overheated.

-If you have to use an extension cord inevitably, make sure that the rated

capacity is not exceeded.

Do not pull the power cord only from a distance.

Keep the product away from the children or unskilled people.

Do not attempt to disassemble, repair or alter the device.

-You may suffer from electric shock or hurt.

Do not put a heavy stuff on the power cord.

Never use the device with any chemical that is not described.

-Physical injury or damage to the product may result.

Do not install this device in the area where ventilation does not function

properly or in oily, smoky, humid, dusty and water splashing places.

-Its durability can be compromised by corrosion.

You have to use a grounded socket and an approved power-cord.

-Electric shock due to electric leakage may result.

Shut off the power to prevent electric shocks if the device is not

working.

Precautions for safe operation ※Please observe the following instructions that are precautions for safe and correct operation to prevent unexpected hazards of damage and injury.

※ Do not storage the solution for a long period.

※ Avoid direct contact with eyes.

※ Do not inhale the fine particles such as spray evaporation or gas.

※ If you have sensitive skin, wear protective equipment such as

rubber gloves.

※ Do not sell the disinfectant created from the device.

※ Do not use the created solution directly when cooking or as

drinking water.

※ Do not use the solution on sesame seeds.

Measures

1. When the large amounts of disinfectant get into the eyes, hold eye

open and rinse gently with tap water immediately.

2. Move to the place with fresh air when you feel dizzy.

3. When you drink plenty of disinfecting water, drink clean water or milk

and contact the nearest hospital.

Page 21: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 21

www.naoclean.com

※ If any of the follow situations occur, check the cause of the problem and resolve.

Check the saline solution

4. Inspection > Cautions / Check the saline solution / Check the error / Electrode replacement & Diagram

Cause Action

Supply of saline solution was inadequate because the filter is blocked.

Clean the filter with tap water or exchange it. (Refer to page 17)

No saline solution. Make the saline solution and pour into the tank. (Refer to page 18)

Pump does not work. Request a repair by contacting the seller.

Dilution rate is not correct. Refer to page 18

Saline solution supply hose was blocked or placed up of the tank.

Lay down next to the tank and do not push the hose.

Saline solution is not supplied normally.Turn off the power and check the Saline solution control hose if it backflows or not.And if there’s something wrong, you have to check the pressure in the electrolytic bath.But nothing wrong, exchange the check valve.

Saline solution is not supplied normally because check valve is blocked.

If some debris or residues are left in the Saline solution tank, the components will be damaged. So, you have to clean the tank after using and use prescribed pure salt.

Clean or exchange the check valve. (Refer to page 17)

Page 22: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 22

Check the error

4. Inspection > Cautions / Check the saline solution / Check the error / Electrode replacement & Diagram

※Do not touch, modify or repair the parts inside the device.※In case of abnormal operation, unplug the power cord and request a repair by contacting the seller.

CauseCondition Action

Power lamp is not turned on.-Power cord is unplugged from the socket.-Burnt out fuse.

Check the cord, fuse and plug in the cord.

Water and saline solution arenormally supplied, but the num-ber of the power meter inside the device does not increase anddisplay error.

Abnormal SMPS power due to certain reasons or PCB circuit problem.

Request a repair by contacting the seller.

Saline checking lamp is blinking and buzzer alerts.

Lack of saline solution or check the electrode. (Refer to page 23)

Make the saline solution and fill the tank.(Refer to page 18)

Water checking lamp is blinking and buzzer alerts.

Lack of water supply. Check the Water supply valve whether it is normally supplied or not.

Abnormally low Active chlorine concentration.

Refer to the electrodes replacement cycle.(Refer to page 23) Request a repair by contacting the seller.

Leaking water. Short circuit or piping problem. Request a repair.

When you have twinge because of micro electricity.

-Device is not grounded properly.-Socket is not grounded.

Check your socket is grounded. If not, you have to connect some wire between Stainless steel parts of the device and Water supply valve.

Page 23: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 23

www.naoclean.com

1. When the consumption of saline solution is significantly increasing abnormally. 2. If the display number inside the device decreases during its normal operating process and ‘Er (error)’ message keeps showing up. 3. When the smell of disinfectant significantly decrease.

※ The lifespan (approx. 10,000 hours) of the electrode may vary depending on water quality.※ Request a repair in case of the above situation after a prolonged use.

Electrodes replacement period

Block diagram

4. Inspection > Cautions / Check the saline solution / Check the error / Electrode replacement & Diagram

-Tap water-Underground water

ConnectionAC 220/230V50/60Hz

Decompression valve

Solenoid valve

Water control valve

Generate disinfecting water

POWERPCB

MAIN PCB FAN

SMPS

Electrode

Spout

Pump

Saline solution tank

Page 24: washing stand NaOClean Manual · Safe for human NaOClean guarantees both the safety of users and a health-risk-free user experience. NaOClean is safer on your skin than other chemical

page 24 Quality Warranty

- This product was manufactured through strict quality control and inspection.

- Services arising from failure that takes place after the expiry of the warranty

period will be charged for.

- During the warranty period, one year from the date of purchase, this product

shall be serviced free of charge as far as manufacturing defect is concerned.

- This product is warranted in accordance with the description on the quality

warranty.

Regulations of Product Warranty

- Free services: For any failure related to the function and performance of the product that takes place in the course of normal operation within the warranty period.

- Charged services 1. When the warranty period has expired; 2. During the warranty period, if failure was caused by; - Careless handling of the product. - Unauthorized repair or alteration of the product. - Damage during transportation due to mishandling. - Connection to a wrong power.

※ Please fill out the quality warranty completely and keep it carefully.

Consumer damages compensation

- If you find any abnormality or have a question while using this product, please contact a nearby distributor or our head office.- In order to request for services, you need to present this quality warranty duly filled out. Therefore please keep it carefully. In case you get charged services, please make sure to keep the receipt carefully.

How to request for serviceProduct Name

Model

A l icense number

Warranty Per iod

Date of purchase

Purchaser :

address

Point of purchase :

address

Sterilizing, deodorizing washing stand NaOClean

DES-WS850

One (1) year from the date of purchase

Food Additive Production Approval NaOClean(No. 2006-라-0001 Issue)

This manual was written as of October 2013. The content is subject to changes due to continued research and development.

Anyang MegaValley No. 207, 799 Gwanyang 2-dong, Dongan-gu, Anyang, Gyeonggi-do, Korea.

tel. +82-31-424-0100 web. www.dndele.comfax. +82-31-424-4036 e mail. [email protected]

+82-1577-7544A/S