    It is critical that Design Professionals

    understand that the conditions that they are

    typically detailing on the building must meet the

    challenges of the installer in the field.

    BUILDING ENVELOPE

    The building envelope includes everything thatThe building envelope includes everything that

    separates the interior of a building from theseparates the interior of a building from the

    outdoor environment, including theoutdoor environment, including the windowswindows, walls,, walls,

    foundation, basement slab, ceiling, roof, andfoundation, basement slab, ceiling, roof, and

    insulation.insulation.

  • 8/3/2019 Wall Flashing V1

    3/23

    UNDERSTANDING,UNDERSTANDING,

    AND DETAILING,AND DETAILING,THE BUILDINGTHE BUILDING

    ENVELOPEENVELOPE

  • 8/3/2019 Wall Flashing V1

    4/23

    EXTERIOR ELEVATION EXAMPLEEXTERIOR ELEVATION EXAMPLE

    EXTERIOR ELEVATION EXAMPLEEXTERIOR ELEVATION EXAMPLE

  • 8/3/2019 Wall Flashing V1

    5/23

    ROOF PLAN EXAMPLEROOF PLAN EXAMPLE

  • 8/3/2019 Wall Flashing V1

    6/23

    EXTERIOREXTERIOR

    WINDOW SILL EXAMPLEWINDOW SILL EXAMPLE

  • 8/3/2019 Wall Flashing V1

    7/23

    THROUG

    H WALLTHROUG

    H WALLFLASHINGFLASHING

  • 8/3/2019 Wall Flashing V1

    8/23

    Through-wall Base Flashing

    Utilize preformed outside and inside corners

    whenever possible to eliminate pinhole leaks that

    typically occur when straight membrane is

    overlapped

  • 8/3/2019 Wall Flashing V1

    9/23

    This weep is not an acceptable

    solution to wicking water from

    the wall cavity. The tube tends

    to get filled with bugs and

    debris.

    This weep is an acceptable

    solution to wicking water from

    the wall cavity. The louvers allow

    ventilation into the cavity without

    the bugs and debris. It is alsorecommended that these louvers

    be installed at the top of the wall

    to increase the cavity ventilation.

  • 8/3/2019 Wall Flashing V1

    10/23

    This mortar net is an excellent way of preventing

    masonry cement from packing or bridging in behind

    the exterior veneer and allowing the water to weep

    down to the masonry weeps.

  • 8/3/2019 Wall Flashing V1

    11/23

    WIN

    DOW / DOORWIN

    DOW / DOORFLASHINGSFLASHINGS

  • 8/3/2019 Wall Flashing V1

    12/23

    WATER PENETRATION DUE TO IMPROPER

    FLASHING OF STOREFRONT SYSTEM

  • 8/3/2019 Wall Flashing V1

    13/23

    WATER STOP FLASHING INSTALLED IN

    CONCRETE SLAB UNDER STOREFRONT SYSTEM

  • 8/3/2019 Wall Flashing V1

    14/23

    SEALANT HAS

    DETERIORATED

    AND HAS LEFT

    BACKER RODEXPOSED.

    ALLOWING

    MOISTURE INTO

    THE WALL

    CAVITY.

    WATER PENETRATION DUE TO IMPROPER

    MATENANCE OF THE UNIT

  • 8/3/2019 Wall Flashing V1

    15/23

  • 8/3/2019 Wall Flashing V1

    16/23

    Aluminum Head flashingAluminum Head flashing

  • 8/3/2019 Wall Flashing V1

    17/23

    Install membrane

    on top of sill for the

    through wall

    flashing

    Installation of

    aluminum subsill

    Installation of End

    Dams

  • 8/3/2019 Wall Flashing V1

    18/23

    Aluminum Backer

    Plate installed in

    throat of frame.

    CORNER FLASHING DETAILALUMINUM WINDOW THROAT

    CORNER FLASHING DETAIL

  • 8/3/2019 Wall Flashing V1

    19/23

    Mullion detail

    Vertical metal

    mullion flashing

    offset to extend

    behind gypsheathing

    Continuous metal

    receiver flashing

    MULLION FLASHING DETAIL

    Continuous #66

    Plaster Stop

    Mullion detail

  • 8/3/2019 Wall Flashing V1

    20/23

    Flashing is critical where clerestory

    windows occur.

    Continuous damp

    proofing over thegyp sheathing

    Try to integrate

    roofing design with

    the window flashingdesign

  • 8/3/2019 Wall Flashing V1

    21/23

    FINAL RESULTSFINAL RESULTS

  • 8/3/2019 Wall Flashing V1

    22/23

    TheThe finalfinal resultresult isis aa waterwater tighttight openingopening withwith aa

    sealseal envelopeenvelope assemblyassembly

  • 8/3/2019 Wall Flashing V1

    23/23

    972.874.1388

    1.888.874.1388

    www.armko.com

    Established 1983

    Specified more than 100,000,000 square feet of

    roofing in Texas

    Zero roof failures

    Assist Design Professionals in preparing

    and detailing with AutoCAD, the roof

    plans and details required for any type of

    project.

    ARMKO Philosophy:

    Whether the building is in the Coastal Bend area

    or in the Panhandle of Texas, the Envelopeshould be able to accommodate the conditions

    of the region. We further feel that our experience

    in the field, quality assurance, and

    understanding of why a building leaks makes

    our firm unique in the Industry.