wainscot paneling | design request form | walls | new england classic
TRANSCRIPT
8/7/2019 Wainscot Paneling | Design Request Form | Walls | New England Classic
http://slidepdf.com/reader/full/wainscot-paneling-design-request-form-walls-new-england-classic 1/6RPX-LT21- 12.23.05 Page 1 of 6
By providing the requested design information, we will provide you with a detailed wall
panel design, bill of materials list and a price for your project.
Wall Design Request FormThis form is for Wainscoting Horizontal wall application only.
Please use Stair Design Request Form for angled stair walls.
Phone: (888) 460-6324, Fax: (256) 767-2916 or visit us at www.NewEnglandClassic.com
Date: __________________________________
Project Name: _______________________________ Project Contact: _________________________________
Address: ______________________________________City_________________State______Zip___________
Daytime Phone: ______________________Fax: _____________________E-mail: _______________________
Dealer Name: ________________________________Dealer Contact: _________________________________
STEP 1: Define Project Stage.
Wallboard has been applied or is existing. Room is rough framed.
Thickness of wallboard:
1/2”
5/8”
other _________Thickness of finished floor material: 3/8” 1/2” 3/4” other _________
STEP 2: Define Product Scope. Please specify the following selections with a check mark in the provided box.
1. Style: ClassicTraditional® (Raised panel with beaded rails)
ClassicAmerican® (Flat panel with beaded rails)
ClassicModern® (1/8” Revealed flat panel with flat rails)
ClassicBeadboard® (Beaded design panels with beaded rails)
ClassicCottage™ (2-tier system 12”x 12” panel above beadboard panel with beaded rails)
ClassicRustic™ (Hand-carved and scraped panels with matching rails)
2. Specifications:ClassicTraditional, ClassicAmerican and ClassicModern
System Height: 32” 36” 40” 44” 56” 60” Custom Ht______
Panel Width: 9” 12” 15” 18” 23” 31” Custom_________
ClassicBeadboardSystem Height: 32” 36” 40” 44” 69” 73” 104” 108” Custom________
ClassicCottageSystem Height: 48” 56”
Panel Style in Top Tier (Required): Flat Raised
ClassicRustic
System Height: 36” 44”
3. Species & Finishes:
ClassicTraditional, ClassicAmerican, ClassicBeadboard, ClassicCottage and ClassicModernWood Species: __Paintable/ Primed __Oak __Maple __Cherry
Finishes: _Unfinished _Primed _White Paint _Natural _Golden Honey _Warm Chestnut __Cinnamon
_Nutmeg _Merlot _ Tuscan Coffee __ Custom (submit color swatch for matching. $100 upcharge appli
ClassicRusticSpecies: Only Available in Hand-Scraped Maple
Finish: _Unfin. _Natural _ Golden Honey _ W.Chestnut _Cinnamon _Nutmeg _Merlot _Tuscan Coffe
*Please continue to page 2 of the Wall Design Request Form to complete your design request.
8/7/2019 Wainscot Paneling | Design Request Form | Walls | New England Classic
http://slidepdf.com/reader/full/wainscot-paneling-design-request-form-walls-new-england-classic 2/6
RPX-LT21- 12.23.05 Page 2 of 6
Wall Design Request Form (continued)
Project Name: _______________________________________________Date: _______________________
4. Baseboard(s):
New England Classic wall systems are provided with a standard baseboard in heights of 4” or 8”depending on system height. If you choose to use a secondary baseboard in conjunction with New
England Classic baseboard, please check the box below and supply the dimensions requested.
Built-up baseboard (REQUIRED - Enter dimensions below.)
5. Casing Option(s) (i.e. door & window trim): Please select one (1) option. Please supply appropriate New England Classic CasingPak. (4 ½” system) Owner supplied or already existing casing (REQUIRED - Enter dimensions below.)
STEP 3: Sketch Room Plan and Select Appropriate Project Measuring Guideline.1. Copy the Design Request & Sketch Sheet for each room.
2. Fill in name of room on each sheet.
3. Please determine project conditions and complete your Project Design in accordance to the ProjectMeasuring Guideline (#) indicated below.
If Owner is keeping existing casing. Follow Project Measuring Guideline Example #1 If using New England Classic Casing. Follow Project Measuring Guideline Example #2 If Owner is supplying casing which is not currently installed. Follow Project Measuring
Guideline Example #2 If project is in rough framing stage. (No wallboard installed) Follow Project Measuring
Guideline Example #3
STEP 4: Submit to New England Classic.
• Fax all pages to Design Services at (256) 767-2916 or
• Mail to: New England Classic
Attention: Design Services
4145ParkwayDrive Florence,AL 35630
• For further assistance Call NEC at: (888) 460-6324
*Please continue to the Wall Design Request Data Chart and Sketch Sheet to complete your design request.
(BY OTHERS)BASE
4" OR 8" RAIL
( V A R I E S )
6 " - 1 6 "
H
T
Thickness (T): ____________Height (H): ______________
T
W
Thickness (T): ____________
Width (W): ______________
8/7/2019 Wainscot Paneling | Design Request Form | Walls | New England Classic
http://slidepdf.com/reader/full/wainscot-paneling-design-request-form-walls-new-england-classic 3/6
RPX-LT21- 12.23.05 Page 3 of 6
Wall Design Request Data Chart & Sketch SheetPrint your Project Name to allow Design Services to track Sketch Sheet information
to the proceeding Design Request Form data sheet.
Project Name: ________________________________ Date: _______________________________________
General Notes:
Room Name: ________________________
*Please make a copy of Wall Design Request & Sketch Sheet for each room.
ITEM
DOOR = D
WINDOW = W
HEATER = H
OTHER = O
UNIT SIZEWINDOW
SILL/JAMB
CASING-DIMENSIONS
REQUIRED IF NEW OR
REPLACING CASING
D W H O WIDTH HEIGHT HEIGHT WIDTH REVEAL
1
2
3
4
5
Design Sketch Area:
8/7/2019 Wainscot Paneling | Design Request Form | Walls | New England Classic
http://slidepdf.com/reader/full/wainscot-paneling-design-request-form-walls-new-england-classic 4/6
RPX-LT21- 12.23.05 Page 4 of 6
Wall Design Request Data Chart & Sketch SheetPrint your Project Name to allow Design Services to track Sketch Sheet information
to the proceeding Design Request Form data sheet.
Project Name: ________________________________ Date: _______________________________________
General Notes:
Room Name: _________________________
*Please make a copy of Wall Design Request & Sketch Sheet for each room.
ITEM
DOOR = D
WINDOW = W
HEATER = H
OTHER = O
UNIT SIZEWINDOW
SILL/JAMB
CASING-DIMENSIONS
REQUIRED IF NEW OR
REPLACING CASING
D W H O WIDTH HEIGHT HEIGHT WIDTH REVEAL
1
2
3
4
5
Design Sketch Area:
8/7/2019 Wainscot Paneling | Design Request Form | Walls | New England Classic
http://slidepdf.com/reader/full/wainscot-paneling-design-request-form-walls-new-england-classic 5/6
RPX-LT21- 12.23.05 Page 5 of 6
Measuring to Existing Casing Example Project Sketch Dimensioned to Existing Cas
Project Data Chart Example
Project Data Chart Example
Project Sketch Dimension to Unit Inside Frame
3'-0"
WINDOW
1'-10" TOTOP OF WINDOW
FRAME 3 ' - 0 "
2 ' - 4 "
9'-0"
2
2'-6"
5 ' - 7 "
1
3'-6"
1 0 ' - 1 1 "
D O O R
H E A T E R
3
2
' - 1 0 "
5 ' - 3 "
2 ' - 1 0 "
Project Measuring Guideline Examples
#1 - Projec t with Existing Casing & Wallboard Installed Follow these guidelines and record your measurements on the sketch
sheets & chart provided. Start with one wall and then repeat for each wall.
1. Measure overall length of walls.
2. Measure from wall corner(s) to outside edge of existing casing on
windows, doors & other items that could interfere with wallpaneling (Do not include switches & outlets). Repeat process
for each wall elevation.
3. Measure width of window & door openings from outside edges of
casing.
4. Measure sill height from bottom of sill to finished floor.
5. Measure height of window & door openings from outside edge of casing
to finished floor.
6. Enter dimension information into project data chart.
7. Sketch project, dimension and label items.
8. See examples below for guidance.
#2 - Projec t with No Casing or Rep lac ing Existing Casing & Wallboa rd Installed
1. Measure overall length of walls.2. Measure from wall corner(s) to uncased frames on windows,
doors & other items that could interfere with wall paneling (Do
not include switches & outlets). Repeat process for each wall
elevation.
3. Measure width of window & door openings from uncased frame
openings.
4. Measure sill height from top of window frame to finished floor.
5. Measure height of window & door openings from uncased frame to finished floor.
6. Enter future casing & reveal width into project data chart.
7. Enter dimension information into project data chart.
8. Sketch project, dimension and label items.
9. See examples below for guidance.
Measuring to Unit Inside Frame- No Casing
WALL
WINDOWFRAME
CASING
WINDOW
MEASURETO EDGE3'-6"2'-3"
1 ' - 9
1 4 " B o t t o m o f
W i n d o w S i l l
7 ' - 1 "
2'-6" 3'-0"
1 ' - 1 0 " T o p o f
W i n d o w F r a m e
6 ' - 6 "
WALL
WINDOWFRAME
WINDOW
MEASURETO INSIDE
EDGE
3 ' - 8 1 / 2 "
1 ' - 1 1 3 / 4 "
3'-8 1/2"
1'-9 1/4" TOB O T T O M O F
W I NDOW S I LL2
1
W I N D O W
3'-1 3/4"
9'-0"
1 0 ' - 1 1 "
D O O R
5 ' - 2 3 / 4 "
2'-1 3/4"
2 ' 1 0 "
H E A T E R
5 ' 3 "
2 ' 1 0 "
3
UNIT SIZE WINDOW
SILL/FRAME
CASING -DIM REQUIRE
IF NEW OR REPLACIN
CASING
HEIGHTHEIGHTWIDTH WIDTH REVEA
1
D = DOOR
W = WINDOW
H = HEATER
O = OTHER
ITEM
2
3
4
5
D W H
3'-6"
3'-6"
7'-1"
7'-1"
1'-9 1/4"99
9 5'-3" 0'-9"
O
UNIT SIZE WINDOW
SILL/FRAME
CASING -DIM REQUIRE
IF NEW OR REPLACING
CASING
HEIGHTHEIGHTWIDTH WIDTH REVEA
1
D = DOORW = WINDOW
H = HEATER
O = OTHER
ITEM
2
3
4
5
D W H
3'-0"
3'-0"
6'-6"
6'-6"
1'-10"99
9 5'-3" 0'-9"
O
0'-4" 0'-1/4
0'-4" 0'-1/4
8/7/2019 Wainscot Paneling | Design Request Form | Walls | New England Classic
http://slidepdf.com/reader/full/wainscot-paneling-design-request-form-walls-new-england-classic 6/6
RPX-LT21- 07.13.11 Email: [email protected] Phone: (888) 460-6324 Page 6 of 6
Project Measuring Guideline Examples
#3 – Projec t at Rough Framing Stage with no wa llboard installed Follow these guidelines and record your measurements on the sketch
sheets & chart provided. Start with one wall and then repeat for each wall.
1. Measure overall length of walls.
2. Measure wall corner(s) to inside edge of rough opening (RO) for windows, doors & other items that could interfere
with wall paneling (Do not include switches & outlets). Repeat process for each wall elevation.
3. Measure width of window & door rough openings (RO).
4. Measure sill height from sub floor to inside top edge of sill rough opening.
5. Measure height of rough opening for window & door openings, from sub floor to bottom of header.
6. Enter dimension information into project data chart.
7. Enter future casing width & reveal width to be applied or installed.
8. Sketch project, dimension and label items.
9. See examples below for guidance.
Project Data Chart Example
Measuring Rough framing- Window Pro ect Sketch Dimension to Unit Inside Frame
W A L LW I N D O W
M E A S U R ET O I N S I D E
E D G E
O P E N I N G F R A M I N G
3'-0"
1 ' - 1 0 " T o p o f
W
i n d o w F r a m e
6 ' - 6 "
3'-0"
WINDOW
1'-10" TOTOP OF WINDOW
FRAME
3 ' - 0 "
2 ' - 4 1 / 2 "
9'-1"
2
2'-6 1/2"
5 ' - 7 1 / 2 "
13'-6 1/2"
1 1 ' - 0 "
D O
O R
H E A T E R
3
2 ' - 1 0 1 / 2 "
5 ' - 3 "
2 ' - 1 0 1 / 2 "
UNIT SIZE WINDOW
SILL/FRAME
CASING -DIM REQUIRED
IF NEW OR REPLACING
CASING
HEIGHTHEIGHTWIDTH WIDTH REVEAL
1
D = DOOR
W = WINDOW
H = HEATER
O = OTHER
ITEM
2
3
4
5
D W H
3'-0"
3'-0"
6'-6"
6'-6"
1'-10"99
9 5'-3" 0'-9"
O
0'-4" 0'-1/4"
0'-4" 0'-1/4"