vyaire...designed with clinicians in mind… needle protection... we’ve got your problem covered!...
TRANSCRIPT
VyaireArter ial b lood gas samplers
Designed with clinicians in mind…Needle protection... we’ve got your problem covered!The Sure-Lok needle protection device from Vyaire cores the bevel and encapsulates the contaminated needle following the draw. This helps to eliminate the risk of blood splatter if the syringe is dropped. Once in the Sure-Lok, no area of the needle is exposed.
Integrated protectionThe integral safety clips on the syringe allow for audible and visual confirmation that the needle is secure and cannot be removed from the Sure-Lok.
You’ll be seeing redThe Sure-Lok system affords the clinician an unobstructed view of the arterial flash indicating the needle has entered the artery. By using a needle protection device that may obstruct the visibility, the clinician runs the risk of the needle passing through the artery, possibly subjecting the patient to another puncture.
In the way? No way…The clinician retains the freedom of drawing blood without needle protection devices which may get in the way.
ABG - Accurate Blood Gas - with the patient in mind…Having blood gases drawn can be traumatic to the patient. Vyaire has taken many steps to help ensure that the first stick is the only stick!
Lyophilized heparinFocused on preserving the sample integrity, all Vyaire samplers utilize lyophilized heparin, which reduces the risk of dilution error which may be associated with liquid heparin. Accurate ionized calcium results shouldn’t be a balancing act. To help ensure the accuracy of ionized calcium results, Vyaire uses reduced heparin to compensate for calcium binding. Our reduced heparin syringes offer 3.2 I.U. (N) of heparin in the 1 mL size and 7.9 I.U. (N) in the 3 mL size.
Heparin: How much is enough?Empirical experience and review has shown that it only takes < 3 units of heparin per 1 mL of blood to adequately stop coagulation for approximately 70 minutes following agitation*. All of our ABG products, including our reduced heparin formulation, exceed this amount.
Air is never a good thing when analyzing blood gases.Air can compromise the sample, leading to erroneous results. The pre-set plunger (on all syringes except Aspirator) integrates a rear venting system, in which air automatically evacuates out the back of the syringe as the blood fills during the draw.
Because you don’t always get what you need…Short draws happen. When they do, you need an efficient way to remove the air left in the syringe. Coupled with the Sure-Lok needle protection device, the rear venting enables the user to evacuate the air bubbles without passing the bubble through the blood sample. An integral media allows only the air to escape, and then expands and seals when contacted by blood.
Skip the flip!Other air bubble removal devices require the entire sample be inverted for evacuation. This technique requires the bubble to pass through the blood sample, which may spur smaller bubbles. It may become difficult for the clinician to expel all of the unwanted air. Utilizing the Sure-Lok, the syringe remains in one position and the air does not pass through the blood.
Arterial Blood Sampler1 mL syringe with 56.5 I.U. (N) of heparin 3 mL syringe with 113 I.U. (N) of heparin
Aspirator Arterial Blood SamplerNeedleless syringes available in 1 or 3 mL sizes for use with arterial lines.
Reduced Heparin Arterial Blood SamplerConfigurations of our arterial blood gas samplers and aspirating arterial blood gas samplers are available in a reduced heparin formulation. This formula, for use when analyzing electrolytes, has 3.2 I.U. (N) of heparin in the 1 mL syringe, and 7.9 I.U. (N) in the 3 mL syringes.
Sure-LokOne hand activated needle protection device allows the sample and needle to be sealed from the atmosphere while the clinician tends to the patient.
Rear venting featureWhen using the Sure-Lok, simply vent remaining air in the syringe by gently pressing the plunger with one finger. No additional filters or other components are required.
Non Vented Vented
*https://dailymed.nlm.nih.gov/dailymed/fda/fdaDrugXsl.cfm?setid=6467d400-d373-4137-af06-568b98813c8e
Aspirator arterial blood gas sampler603EU Aspirator Arterial Blood Gas Sampler: 3cc aspirating syringe 113 I.U. (N) heparin, luer slip 100 / CS
601RH Airlife Aspirator Arterial Blood Gas Sampler: 1cc aspirating syringe, Airlife Reduced Heparin Arterial Blood Gas Sampler 3.2 I.U. (N) heparin luer slip 100 / CS
601EU Aspirator Arterial Blood Gas Sampler: 1cc aspirating syringe, 56.5 I.U. (N) heparin, luer slip 100 / CS
601W Aspirator Arterial Blood Gas Sampler syringe, 56.5 I.U. (N) heparin, 3ml waste syringe, pack quantity 100 / CS
60350EU Aspirator Arterial Blood Gas Sampler, 3ml Airlife Aspirator Arterial Blood Gas Sampler syringe, 56.5 I.U. (N) heparin, pack quantity 100 / CS
603CHAspirator Arterial Blood Gas Sampler, 3ml Airlife Aspirator Arterial Blood Gas Sampler syringe, luer lock, 113 I.U. (N) heparin, 5ml waste syringe, label, ice bag, pack quantity
100 / CS
603L Aspirator Arterial Blood Gas Sampler, 3ml Airlife Aspirator Arterial Blood Gas Sampler syringe, luer lock, 113 I.U. (N) heparin, pack quantity 100 / CS
603RAH Aspirator Arterial Blood Gas Sampler, 3ml Airlife Aspirator Arterial Blood Gas Sampler syringe, luer lock, 113 I.U. (N) heparin, 5ml waste syringe, pack quantity 100 / CS
603W Aspirator Arterial Blood Gas Sampler, 3ml Airlife Aspirator Arterial Blood Gas Sampler syringe, 113 I.U. (N) heparin, 5ml waste syringe, pack quantity 100 / CS
605EU Aspirator Arterial Blood Gas Sampler, 5ml Airlife Aspirator Arterial Blood Gas Sampler syringe, 113 I.U. (N) heparin, pack quantity 100 / CS
650NCGSLAspirator Arterial Blood Gas Sampler, 3ml Airlife Aspirator Arterial Blood Gas Sampler syringe, luer lock, (2) 22gx38mm needles, 113 I.U. (N) heparin, labels, Sure Lok (2), arterial and venous labels
50 / CS
Arterial blood sampler 3ml without needle protection4022EU Arterial Blood Gas Sampler: 3cc syringe, 113 I.U. (N) Heparin, 22g needle x 1" needle luer slip 100 / CS
4022LRH Arterial Blood Gas Sampler: 3 cc syringe, Airlife Reduced Heparin Arterial Blood Gas Sampler - 7.9 I.U. (N) heparin, 22g x 1" needle luer lock 100 / CS
4022LL Arterial Blood Gas Sampler: 3cc syringe, 113 I.U. (N) heparin, 22g x 1" needle, luer lock 100 / CS
4023 Arterial Blood Gas Sampler: 3cc syringe, 113 I.U. (N) heparin, 23g x 1" needle, luer slip 100 / CS
4000L Arterial Blood Gas Sampler, 3ml syringe, luer lock, 113 I.U. (N) heparin, needle less 100 / CS
4023LL Arterial Blood Gas Sampler, 3ml syringe, luer lock, 113 I.U. (N) heparin, 23g x 25mm needle, rubber cube stopper 100 / CS
MQ4000 Arterial Blood Gas Sampler, 3ml syringe, luer slip, 113 I.U. (N) heparin, needle less 100 / CS
Arterial blood sampler 3ml with needle protection4000LRH Arterial Blood Gas Sampler: 3cc syringe, luer lock 7.9 I.U. (N) heparin 100 / CS
4022400Arterial Blood Gas Sampler: 3cc syringe, Airlife Reduced Heparin Arterial Blood Gas Sampler 7.9 I.U. (N) heparin, 22g x 1" needle, luer lock, Sure Lok needle protection
100 / CS
4000RH Arterial Blood Gas Sampler: 3cc syringe, luer slip 7.9 I.U. (N) heparin 100 / CS
022LTRU Arterial Blood Gas Sampler, 3ml syringe, 113 I.U. (N) heparin, 22g x 25mm needle, luer lock, Sure Lok protection 100 / CS
4022TRU Arterial Blood Gas Sampler, 3ml syringe, 113 I.U. (N) heparin, luer slip, 22g x 25mm needle, Sure Lok protection 100 / CS
4023LTRU Arterial Blood Gas Sampler, 3ml syringe, luer lock, 113 I.U. (N) heparin, 23g x 25mm needle, Sure Lok protection 100 / CS
4023TRU Arterial Blood Gas Sampler, 3ml syringe, luer slip, 113 I.U. (N) heparin, 23g x 25mm needle, Sure Lok protection 100 / CS
Arterial blood sampler 1ml with needle protection9000RH Arterial Blood Gas Sampler: 1cc syringe, Airlife Reduced Heparin Arterial Blood Gas Sampler 3.2 I.U. (N) heparin 100 / CS
9025TRU Arterial Blood Gas Sampler: 1cc syringe, 56.5 I.U. (N) heparin, 25g x 5/8” needle Sure Lok needle protection 100 / CS
MQ9000 Arterial Blood Gas Sampler: 1cc syringe, 56.5 I.U. (N) heparin 100 / CS
9023RHSL Arterial Blood Gas Sampler: 1cc syringe, Airlife Reduced Heparin Arterial Blood Gas Sampler 3.2 I.U. (N) heparin, 23g x 1” needle, Sure Lok needle protecton 100 / CS
9023TRU Arterial Blood Gas Sampler, 1ml syringe, 56.5 I.U. (N) heparin, leur slip, 23g x 25mm needle, Sure Lok protection 100 / CS
Arterial blood sampler 1ml without needle protection9000CH Arterial Blood Gas Sampler, 1ml syringe, 15.8 I.U.(N) heparin, leur slip 100 / CS
9023 Arterial Blood Gas Sampler, 1ml syringe, 56.5 I.U. (N) heparin, leur slip, 23g x 25mm needle, rubber cube stopper 100 / CS
9025EU Arterial Blood Gas Sampler, 1ml syringe, leur slip, 56.5 I.U. (N) heparin, 25g x 16mm needle, rubber cube stopper 100 / CS
Reduced heparin arterial blood sampler with needle protection4022RHTR Reduced Heparin Arterial Blood Gas Sampler, 3ml syringe, leur slip, 7.9 I.U. (N) heparin, 22g x 25mm needle, Sure Lok protection 100 / CS
Reduced heparin arterial blood sampler4022RH Reduced Heparin Arterial Blood Gas Sampler, 3ml syringe, leur slip, 7.9 I.U. (N) heparin, 22g x 25mm needle, rubber cube stopper 100 / CS
4023LRH Reduced Heparin Arterial Blood Gas Sampler, 3ml syringe, leur lock, 7.9 I.U. (N) heparin, 23g x 25mm needle, rubber cube stopper 100 / CS
4023RH Reduced Heparin Arterial Blood Gas Sampler, 3ml syringe, leur slip, 7.9 I.U. (N) heparin, 23g x 25mm needle, rubber cube stopper 100 / CS
603LRH Reduced Heparin Arterial Blood Gas Sampler, 3ml Airlife Aspirator Arterial Blood Gas Sampler syringe, leur lock, 7.9 I.U. (N) heparin 100 / CS
603RH Reduced Heparin Arterial Blood Gas Sampler, 3ml Airlife Aspirator Arterial Blood Gas Sampler syringe, leur slip, 7.9 I.U. (N) heparin 100 / CS
9025RH Reduced Heparin Arterial Blood Gas Sampler, 1ml syringe, leur slip, 3.2 I.U. (N) heparin, 25g x 16mm needle, rubber cube stopper 100 / CS
Cat. no. Syrin
ge
Size
(mL)
Ven
ted
Syr
ing
e
Tota
l Hep
arin
per
Sam
ple
r (I.
U.-
Inte
rna
tion
al u
nits
)
LL =
Lue
r Lo
ckLS
= L
uer
Slip
Ga
uge
Leng
th (i
nch)
Ga
uze
Pad
(2x2
,2
pa
ds
per
pa
cka
ge)
Alc
ohol
Pre
p P
ad
Povi
don
e-Io
din
ePr
ep P
ad
Lab
el (“
3” d
enot
es3-
pa
rt, “
S” d
enot
esSp
ecia
l)
Band
ag
e (S
tand
ard
,C
hara
cter
, Ela
sto)
Ice
Bag
(“S”
)d
enot
es S
pec
ial
Nee
dle
Pro
tect
ion
Shea
th
Cub
e St
opp
er
Wa
ste
Syrin
ge
(mL)
Case qty.
Reduced heparin 3 mL syringes
4000LRH 3 • 7.9 LL 100
4000RH 3 • 7.9 LS 100
4022400 3 • 7.9 LL 22 1 • 100
4022LRH 3 • 7.9 LL 22 1 • 100
4022RH 3 • 7.9 LS 22 1 • 100
4022RHTR 3 • 7.9 LS 22 1 • 100
402324 3 • 7.9 LL 23 1 • 400
4023322 3 • 7.9 LS 23 1 • 100
4023400 3 • 7.9 LL 23 1 • 100
4023LRH 3 • 7.9 LL 23 1 • 100
4023RH 3 • 7.9 LS 23 1 • 100
Reduced heparin 3 mL kits
4023522 3 7.9 LS 23 1 • • • • • • • 100
4023966 3 7.9 LL 23 1 • • • • • • 100
4423LRHT 3 7.9 LL 23 1 • • • • • • • 100
4800008 3 7.9 LL 23 1 • • • • • • 100
Reduced heparin 1 mL syringes
9000RH 1 3.2 LS 100
9023RHSL 1 3.2 LS 23 1 • 100
9025RH 1 3.2 LS 25 5/8 • 100
9025RHTR 1 • 3.2 LS 25 5/8 • 100
Reduced heparin 1 mL kits
9425080 1 3.2 LS 25 5/8 • • • • • • • 100
9523RSL 1 3.2 LS 23 5/8 • • • • 100
Reduced heparin aspirators
601LRH 1 3.2 LL 100
601RH 1 3.2 LS 100
603LRH 3 7.9 LL 100
603RH 3 7.9 LS 100
Reduced heparin syringes and kits
Cat. no. Syrin
ge
Size
(mL)
Ven
ted
Syr
ing
e
Tota
l Hep
arin
per
Sa
mp
ler
(I.U
.-In
tern
ati
ona
l uni
ts)
LL =
Lue
r Lo
ck
LS =
Lue
r Sl
ip
Ga
uge
Leng
th (i
nch)
Ga
uze
Pad
(2x2
, 2
pa
ds
per
pa
cka
ge)
Alc
ohol
Pre
p P
ad
Povi
don
e-Io
din
e Pr
ep
Pad
Lab
el ("
3" d
enot
es
3-p
art
, "S"
den
otes
Sp
ecia
l)
Band
ag
e (S
tand
ard
, C
hara
cter
, Ela
sto)
Ice
Bag
("S"
) den
otes
Sp
ecia
l
Nee
dle
Pro
tect
ion
Shea
th
Cub
e St
opp
er
Wa
ste
Syrin
ge
(mL)
Case Qty
ABG 3 mL syringes Lyophilized heparin = 113 I.U
4000011 3 • 113 LS 400
4000L 3 • 113 LL 100
4022EU 3 • 113 LS 22 1 • 100
4022LL 3 • 113 LL 22 1 • 100
4022LTRU 3 • 113 LL 22 1 • 100
4022TRU 3 • 113 LS 22 1 • 100
4023 3 • 113 LS 23 1 • 100
402324 3 • 113 LL 23 1 • 400
4023LL 3 • 113 LL 23 1 • 100
4023LTRU 3 • 113 LL 23 1 • 100
4023TRU 3 • 113 LS 23 1 • 100
MQ4000 3 • 113 LS 100
ABG 3 mL kits Lyophilized heparin = 113 I.U.
4022MGTR 3 113 LL 22 1 • • • • • • 100
4023099 3 113 LS 23 1 • • • • • 100
4023500 3 113 LS 23 1 • • • • • 100
4023755 3 113 LS 23 1 • • • 100
4422LTRU 3 113 LL 22 1 • • • • • • • 100
4422TRU 3 113 LS 22 1 • • • • • • • 100
4423LTRU 3 113 LL 23 1 • • • • • • • 100
4423SL1 3 113 LL 23 1 • • • • • 100
4423TRU 3 113 LS 23 1 • • • • • • • 100
4523670 3 113 LS 23 1 • • • • 100
4623L 3 113 LL 23 1 • • • • 100
4623LTRU 3 113 LL 23 1 • • • • 100
4623TRU 3 113 LS 23 1 • • • • • 100
4800009 3 113 LL 22 1 • • • • 100
4800011 3 113 LL 23 1 • • • • 100
4800023 3 113 LL 22 1 • • • • 100
4800038EU 3 • 113 LL 23 1 • • • • • • 100
Arterial blood gas sampling kits
Cat. no. Syrin
ge
Size
(mL)
Ven
ted
Syr
ing
e
Tota
l Hep
arin
per
Sa
mp
ler
(I.U
.-In
tern
ati
ona
l uni
ts)
LL =
Lue
r Lo
ck
LS =
Lue
r Sl
ip
Ga
uge
Leng
th (i
nch)
Ga
uze
Pad
(2x2
, 2
pa
ds
per
pa
cka
ge)
Alc
ohol
Pre
p P
ad
Povi
don
e-Io
din
e Pr
ep
Pad
Lab
el ("
3" d
enot
es
3-p
art
, "S"
den
otes
Sp
ecia
l)
Band
ag
e (S
tand
ard
, C
hara
cter
, Ela
sto)
Ice
Bag
("S"
) den
otes
Sp
ecia
l
Nee
dle
Pro
tect
ion
Shea
th
Cub
e St
opp
er
Wa
ste
Syrin
ge
(mL)
Case Qty
Aspirators
601EU 1 56.5 LS 100
601W 1 56.5 LS 3 100
603EU 3 113 LS 100
603RAH 3 113 LL 5 100
603W 3 113 LS 5 100
605EU 5 113 LS 100
ABG 1 mL syringes
9000MU 1 • 56.5 LS 3 100
9023 1 56.5 LS 23 1 • 100
9023TRU 1 56.5 LS 23 1 • 100
9025EU 1 56.5 LS 25 5/8 • 100
9025TRU 1 56.5 LS 25 5/8 • 100
ABG 1 mL kits
9025510 1 56.5 LS 25 5/8 • • • • • 100
9423TRU 1 56.5 LS 23 1 • • • • • • • 100
9425TRU 1 56.5 LS 25 5/8 • • • • • • • 100
9425611 1 56.5 LS 25 5/8 • • • • • • • 100
9722SL 1 56.5 LS 22 1 • • • • • 100
MQ9000 1 56.5 LS 100
Neonatal cord ABG kit
650NCGSL 3 113 LL 22 (x2) 1.5 • • 50
Arterial blood gas sampling aspirators and kits
F o r g l o b a l d i s t r i b u t i o n . © 2020 Vyaire. Vyaire and the Vyaire logo are trademarks or registered trademarks of Vyaire Medical, Inc., or one of its af f i l iates. Medical devices class I Ia according to Medical Devices Directive 93/42/EEC. Please read the complete Instructions For Use that come with the devices or fol low the instructions on the product labell ing. VYR-GBL-2000079
vyaire.com
G L O B A L H E A D Q U A R T E R S
Vyai re Medica l , Inc.
26125 Nor th R iverwoods B lvdMettawa, I L 60045USA
A U S T R A L I A N S P O N S O R
Sui te 5.03, B u i ld ing C
1 1 Ta lavera RoadMacquar ie Park , NSW 21 13Aust ra l ia
Vya i re Medica l , Inc. 26125 Nor th R iverwoods B lvd Mettawa, I L 60045USA
EMERGO EUROPEPr insessegracht 202514 AP The HagueThe Nether lands
2797