vwr - electrochemistry-meters & probes

32
ELECTROCHEMISTRY METERS & PROBES • HQd Meters & IntelliCAL Probes • sensION + Meters & Probes • H-Series Meters & Probes • Pocket Pro Testers

Upload: megacob

Post on 19-Jan-2016

50 views

Category:

Documents


1 download

DESCRIPTION

environment monitoring equipment

TRANSCRIPT

Page 1: Vwr - Electrochemistry-meters & Probes

ELECTROCHEMISTRYMETERS & PROBES

• HQd™Meters & IntelliCAL™ Probes

• sensION™+Meters & Probes

• H-Series Meters & Probes

• Pocket Pro Testers

Page 2: Vwr - Electrochemistry-meters & Probes

21.800.932.5000

UNIVERSAL METERS & PROBES

HQd™Meters & IntelliCAL™ Probes

SMART PROBESHach, the leader in water quality, has developed a customizedsolution for water quality testing that takes the guesswork out ofyour measurements. Designed for your water applications, theHach smart probes feature a built-in temperature sensor, andautomatically recognize the testing parameter, calibration history,and method settings to minimize errors and setup time.

H-Series Meters & Probes

NON-GLASSHach’s rugged, non-glass H-Series family of pH sensorsresist damage and store dry to eliminate maintenance inlaboratory and field testing of difficult applications. Usewith Hach’s H-Series benchtop or portable meters in areaswhere glass is not preferred such as rugged, outdoor, andfood applications.

Pocket Pro & Pocket Pro+ Testers

sensION®+ Meters & Probes

COMPLETE SIMPLICITYHach sensION+, an all-in-one system with guided menu navigationmakes general testing fast and simple. Each system is designed tobe used in a wide variety of applications and comes complete witheverything you need to start testing.

SPECIALTY METERS & PROBES

HQd sensION+

Ease of Use Accuracy & Performance Durability Flexibility

Pocket Pro and Pocket Pro+ testers measure electrochemical parametersin a broad range of water applications. The family of 12 testers offersconvenient portable solutions for pH, ORP, conductivity, TDS, salinity, andtemperature, delivering accurate results you can be confident in. ThePocket Pro+ testers take the value a step further with replaceable sensors,powerful backlight, and multi-parameter tester options.

Page 3: Vwr - Electrochemistry-meters & Probes

3vwr.com

HACH’S METERS & PROBES FAMILY

PARAMETERS

pHGlass

Non-glass (ISFET)

Conductivity

Resistivity

Salinity

TDS

Ammonia

Ammonium

Chloride

Dissolved OxygenLuminescent (LDO®)

BOD Probe (with LDO)

Galvanic

Polarographic

Fluoride

Temperature

Nitrate

ORP/Redox

Sodium

ATTRIBUTES

Multi-parameter Options

Simultaneous Display

Stainless Steel Probes

Auto Probe Recognition

Multiple Cable Lengths

Multi-language Display

On-screen Instructions

Wireless Communication*

USB Connectivity

*For Bluetooth® capable models only

• Compliance monitoringfor drinking water andwastewater

• Laboratory verificationof processinstrumentation

• Industrial plant control

• Environmentalmonitoring

• Rugged fieldapplications

• Compliance monitoringfor drinking water andwastewater

• Laboratory verificationof processinstrumentation

• Industrial plant control

• Environmentalmonitoring

• Beverage qualitytesting

• Beverage qualitytesting

• Industrial plant control

• Boiler/cooling waterapplications

• Water treatmentcontrol

• Food processing

• Beverage qualitytesting

• Academic teaching

• Pharmaceuticalresearch/development

• Industrial plant control

HQdMeters& IntelliCALProbes

sensION+Meters &Probes

Pocket ProTesters

H-SeriesMeters &Probes

Simple Non-glass ConvenientSmart

UNIVERSALMETERS&PROBES SPECIALTYMETERS&PROBES

Page 4: Vwr - Electrochemistry-meters & Probes

41.800.932.5000

HACH pH PROBES BY APPLICATION

HQd

BEST

GOOD

NOT APPLICABLE

89174-020 89347-984 89174-022 89174-024 89174-194 89174-196 89174-198 89174-200 89174-216 89174-218 89174-220 89174-210 89174-212 89174-214 14221-752 14221-754 14221-756 82007-538 82007-53482026-952 82026-954 82026-956 82026-958 82026-950

APPLICATIONS

General Purpose

Drinking Water

Wastewater

Boiler / Cooler

Seawater

Beverage

Food

Education

Pool / Spa

Soils

Pharma

SAMPLE TYPES

Field Measurements rugged non-glass non-glass non-glass non-glass non-glass

Low Ionic Strength

High Temperature

Low Temperature

Page 5: Vwr - Electrochemistry-meters & Probes

5vwr.com

HACH pH PROBES BY APPLICATION

sensION+ H-Series89174-020 89347-984 89174-022 89174-024 89174-194 89174-196 89174-198 89174-200 89174-216 89174-218 89174-220 89174-210 89174-212 89174-214 14221-752 14221-754 14221-756 82007-538 82007-534

82026-952 82026-954 82026-956 82026-958 82026-950

APPLICATIONS

General Purpose

Drinking Water

Wastewater

Boiler / Cooler

Seawater

Beverage

Food

Education

Pool / Spa

Soils

Pharma

SAMPLE TYPES

Field Measurements rugged non-glass non-glass non-glass non-glass non-glass

Low Ionic Strength

High Temperature

Low Temperature

Page 6: Vwr - Electrochemistry-meters & Probes

Specifications

HQ11dDEDICATED

pH/mVPORTABLE METER

HQ14dDEDICATED

CONDUCTIVITYPORTABLE METER

HQ30dSINGLE INPUT

MULTI-PARAMETERPORTABLE METER

HQ40dDUAL INPUT

MULTI-PARAMETERPORTABLE METER

IP Rating IP67 IP67 IP67 IP67Internal Data Storage 500* 500* 500* 500*Inputs M12 digital (1)

for intelliCAL probes M12 digital (1)

for intelliCAL probesM12 digital (1)

for intelliCAL probesM12 digital (2)

for IntelliCAL probesOutputs USB to PC / flash stick USB to PC / flash stick USB to PC / flash stick USB to PC / flash stickResolution 0.1/ 0.01/ 0.001 0.1/ 0.01/ 0.001 0.1/ 0.01/ 0.001 0.1/ 0.01/ 0.001Interface Languages 13** 13** 13** 13**Warranty 3 years 3 years 3 years 3 yearsCompliance CE.WEEE CE.WEEE CE.WEEE CE.WEEEBenchtop with stand with stand with stand with standGLP Features PC Data Transfer Software included included included included Backlight Battery Operation AC and USB Operation optional optional optional included

Cat. No. 89174-000 89174-002 89174-004 89174-006

Parameter

HQ11dDEDICATED

pH/mVPORTABLE METER

HQ14dDEDICATED

CONDUCTIVITYPORTABLE METER

HQ30dSINGLE INPUT

MULTI-PARAMETERPORTABLE METER

HQ40dDUAL INPUT

MULTI-PARAMETERPORTABLE METER

Temperature pH

GlassNon-glass (ISFET)

mV Conductivity TDS Salinity Resistivity Dissolved Oxygen

Luminescent (LDO)BOD Sensor (with LDO)

ORP/Redox Ion Selective Electrodes

Ammonia Ammonium Chloride Fluoride Nitrate Sodium

See pages 10-13 for HQd Bundles & Kits. See page 14 for HQd Accessories.

61.800.932.5000

HQd PORTABLE METERS

*Expanded storage with external USB storage device. **English, German, Spanish, Portuguese, French, Italian, Dutch, Turkish, Polish, Danish, Swedish, Russian, Czech

Now oIering a complete portfolio oftesting parameters with standard, rugged,and ultra options. Hach’s HQd system givesmaximum measurement flexibility and easeof operation with interchangeable probes and automatic parameter recognition.

Page 7: Vwr - Electrochemistry-meters & Probes

Specifications

HQ411dDEDICATED

pH/mV BENCHTOP METER

HQ430dSINGLE INPUT

MULTI-PARAMETERBENCHTOP METER

HQ440dDUAL INPUT

MULTI-PARAMETERBENCHTOP METER

IP Rating IP54 IP54 IP54Internal Data Storage 500* 500* 500*Inputs M12 digital (1) for IntelliCAL probes M12 digital (1) for IntelliCAL probes M12 digital (2) for IntelliCAL probesOutputs USB to PC / flash stick USB to PC / flash stick USB to PC / flash stick Resolution 0.1/ 0.01/ 0.001 0.1/ 0.01/ 0.001 0.1/ 0.01/ 0.001Interface Languages 13** 13** 13**Warranty 3 years 3 years 3 yearsCompliance CE.WEEE CE.WEEE CE.WEEEGLP Features PC Data Transfer Software included included included Backlight Battery Operation Probe Stand optional for all models included included

Cat. No. 89174-008 89174-010 89174-012

Parameter

HQ411dDEDICATED

pH/mV BENCHTOP METER

HQ430dSINGLE INPUT

MULTI-PARAMETERBENCHTOP METER

HQ440dDUAL INPUT

MULTI-PARAMETERBENCHTOP METER

Temperature pH

GlassNon-glass (ISFET)

mV Conductivity TDS Salinity Resistivity Dissolved Oxygen

Luminescent (LDO)BOD Sensor (with LDO)

ORP/Redox Ion Selective Electrodes

Ammonia Ammonium Chloride Fluoride Nitrate Sodium

See pages 10-13 for HQd Bundles & Kits. See page 14 for HQd Accessories.

7vwr.com

HQd BENCHTOP METERS

*Expanded storage with external USB storage device. **English, German, Spanish, Portuguese, French, Italian, Dutch, Turkish, Polish, Danish, Swedish, Russian, Czech

All the benefits of the digital HQd system, with simplified data transfer and easy-to-read results on a large, backlit screen.

Page 8: Vwr - Electrochemistry-meters & Probes

SpecificationsDO LuminescentDissolved Oxygen

DO LuminescentDissolved Oxygen

BOD LuminescentDissolved Oxygen Conductivity Conductivity

Special Feature LDO technology. No membranes.

LDO technology. No membranes.

LDO technology.Designed for BOD

applications. No membranes.

Probe Type Laboratory LuminescentDissolved Oxygen

Rugged LuminescentDissolved Oxygen

Laboratory Laboratory Rugged Outdoor

Range .05 to 20.00 mg/L 0.05 to 20.00 mg/L 0.05 to 20.00 mg/L Cond.: 0.01 µS/cm to 200 mS/cm

TDS: 0 to 50,000 mg/L as NaCl

Salinity: 0 to 42 g/kg or Resist.: 2.5 Ω cm to

49 MΩ cm

Cond.: 0.01 µS/cm to 200 mS/cm

TDS: 0 to 50,000 mg/L as NaCl

Salinity: 0 to 42 g/kg or Resist.: 2.5 Ω cm to

49 MΩ cmAccuracy ±0.1 from 0 to 8 mg/L

±0.2 for greater than 8 mg/L

±0.1 from 0 to 8 mg/L±0.1 for greater than

10 mg/L

±0.05 from 0 to 10 mg/L±0.1 for greater than

10 mg/L

Cond: ±0.5% of rangeTDS: ±0.5% ±1 digit

Salinity: ±0.1, ±1 digit

EC: 0.01 μS/cm (5 digits, maximum)TDS: 0.001, 0.01,

0.1 mg/LSalinity: 0.01 ppt

Temperature Range 0 to 50 °C 0 to 50 °C 0 to 50 °C -10 to 110 °C -10 to 110 °CDimensions (D x L) 0.59 in x 7.87 in

(15 mm x 200 mm)1.77 in x 9.84 in

(45 mm x 250 mm)0.62 in x 7.87 in

(15.875 mm x 200 mm)0.55 in x 7.87 in

(14 mm x 200 mm)1.77 in x 9.84 in

(45 mm x 250 mm)Sensor Type Lumiphore Lumiphore Lumiphore 4-pole graphite,

k = 0.40 cm-14-pole graphite, k = 0.40 cm-1

Material Sensor Body:Polycarbonate / Abs

Sensor Body:Polycarbonate / Abs with Stainless Steel

Sensor Body:Polycarbonate / Abs

Sensor Body: Noryl

Sensor Body: Noryl with Stainless Steel

Cat. No. 89174-014 89174-016 89174-018 89174-028 89174-030

1 meter standard and 5 meter rugged probes described above. All standard probes available in 1 or 3 meter cable lengths. All rugged probes available in 5, 10, 15 or 30 meter cable lengths. *Fits BOD bottle neck size > 15.875mm inside diameter

81.800.932.5000

HQd IntelliCAL PROBES

SpecificationspH Ultra

Refillable Combination pH

Gel-filled Combination pH

Gel-filled CombinationpH

Refillable CombinationpH

Gel-filled CombinationSpecial Feature Fast response time Wastewater and

difficult samplesGeneral purpose.

Clean water samples.Low maintenance

Probe Type Laboratory Laboratory Laboratory Laboratory Rugged OutdoorRange 0 to 14 pH 2 to 14 pH 0 to 14 pH 0 to 14 pH 2 to 14 pHAccuracy ±0.02 pH ±0.02 pH ±0.02 pH ±0.02 pH ±0.02 pHTemperature Range 0 to 80 °C 0 to 50 °C 0 to 80 °C 0 to 80 °C 0 to 50 °CDimensions (D x L) 0.47 in x 7.87 in

(12 mm x 200 mm)0.47 in x 7.87 in

(12 mm x 200 mm)0.47 in x 7.87 in

(12 mm x 200 mm)0.47 in x 7.87 in

(12 mm x 200 mm)1.77 in x 9.84 in

(45 mm x 250 mm)Sensor Type Glass Glass Glass Glass GlassReference Type Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgClJunction Open Open Ceramic pin Ceramic pin OpenMaterial Sensor Body:

Zeonor™

Sensor Body: Epoxy

Sensor Body: Epoxy

Sensor Body: Zeonor™

Sensor Body: Zeonor™

with Stainless SteelFilling Solution — Non-refillable solid gel Non-refillable gel — Non-refillable solid gel

Cat. No. 89174-024 89174-020 89347-984 89174-022 89174-026

Page 9: Vwr - Electrochemistry-meters & Probes

9vwr.com

HQd IntelliCAL PROBES

1 meter standard and 5 meter rugged probes described above. All standard probes available in 1 or 3 meter cable lengths. All rugged probes available in 5, 10, 15 or 30 meter cable lengths.

SpecificationsORP/Redox

Combination Gel-filledORP/Redox

Combination RefillableORP/Redox

Combination Gel-filledAmmonia

Combination ISE Ammonium

Combination ISESpecial Feature Flat disc sensor for

easy cleaning. Low maintenance.

Flat disc sensor for easy cleaning.

Flat disc sensor foreasy cleaning.

Easy-to-replacemembrane modules.

Dry storage & fastresponse time. No

replacement membranes.Probe Type Laboratory Laboratory Rugged Outdoor Laboratory

Combination ISELaboratory

Combination ISERange ± 1200 mV ± 1200 mV ± 1200 mV 0.01 mg/L (5x10-7 M) to

14,000 mg/L (1 M) NH3-N

0.018 mg/L (10-6 M) to9,000 mg/L (0.5 M)

NH4+-N

Accuracy ±0.02mV or 0.05%,whichever is greater

±0.02mV or 0.05%,whichever is greater

±0.02mV or 0.05%,whichever is greater

±0.02mV or 0.05%,whichever is greater

±0.02mV or 0.05%,whichever is greater

Temperature Range 0 to 80 °C 0 to 80 °C 0 to 80 °C 0 to 50 °C 0 to 50 °CDimensions (D x L) 0.47 in x 7.87 in

(12 mm x 200 mm)0.47 in x 7.87 in

(12 mm x 200 mm)1.77 in x 9.84 in

(45 mm x 250 mm)0.47 in x 8.66 in

(12 mm x 220 mm)0.47 in x 8.66 in

(12 mm x 220 mm)Sensor Type Platinum disc Platinum disc Platinum disc Gas sensing: glass

w/ replaceable NH3sensitive membrane

Solid-state PVCmembrane

Reference Type Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgClJunction Open Ceramic pin Open Porous Teflon

Annular RingPorous Teflon Annular Ring

Material Sensor Body: Epoxy

Sensor Body: Epoxy

Sensor Body: Zeonor™

with Stainless SteelSensor Body:

EpoxySensor Body:

EpoxyFilling Solution Non-refillable gel — Non-refillable gel 97021-474 Non-refillable driTEK gelISA Required — — — 97021-772 89173-994

Cat. No. 89233-230 89174-048 89174-044 89174-034 89174-036

SpecificationsChloride

Combination ISE Fluoride

Combination ISE Nitrate

Combination ISE Sodium

Combination ISE Special Feature Dry storage & fast response

time. No replacementmembranes.

Dry storage & fast responsetime. No replacement

membranes.

Dry storage & fast responsetime. No replacement

membranes.

Fast response time

Probe Type Laboratory Combination ISE Laboratory Combination ISE Laboratory Combination ISE Laboratory Combination ISERanges 0.1 mg/L (3x10-6 M) to

35,500 mg/L (1 M) Cl-0.01 mg/L (5x10-7 M) to

19,000 mg/L (1 M) F-

0.1 mg/L (7x10-6 M) to14,000 mg/L (1 M) NO3

--N0.023 mg/L (1x10-6 M) to 23,000 mg/L (1 M) Na+

Accuracy ±0.02mV or 0.05%, whichever is greater

±0.02mV or 0.05%, whichever is greater

±0.02mV or 0.05%, whichever is greater

±0.02mV or 0.05%, whichever is greater

Temperature Range 5 to 50 °C 5 to 50 °C 0 or 50 °C 0 to 50 °CDimensions (D x L) 0.47 in x 8.66 in

(12 mm x 220 mm)0.47 in x 8.66 in

(12 mm x 220 mm)0.47 in x 8.66 in

(12 mm x 220 mm)0.47 in x 8.66 in

(12 mm x 220 mm)Sensor Type Solid-state crystal membrane Solid-state crystal membrane Solid-state PVC membrane GlassReference Type Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgClMaterial Sensor Body: Epoxy Sensor Body: Epoxy Sensor Body: Epoxy Sensor Body: Zeonor™

Filling Solution Non-refillable driTEK gel Non-refillable driTEK gel Non-refillable driTEK gel —ISA Required 89173-988 97021-786 89173-992 97021-782

Cat. No. 89174-038 89174-040 89174-042 89174-032

Page 10: Vwr - Electrochemistry-meters & Probes

101.800.932.5000

HQd & IntelliCAL BENCHTOP KITS

Lab pH/Conductivity KitCat. No. Description89500-882 Lab pH/Conductivity Kit

Includes: HQ440d benchtop meter, PHC281 pH Ultra electrode with 1-m cable,CDC401 conductivity probe with 1-m cable (89174-028), probe stand, pH 4.01buffer (red, 500 mL), pH 7.00 buffer (yellow, 500 mL), pH 10.01 buffer (blue, 500 mL), pH storage solution (500 mL), and NaCl conductivity standard (1000μS/cm, 100 mL).

Lab pH Ultra KitCat. No. Description89233-216 Lab pH Ultra Kit

Includes: HQ440d benchtop meter, PHC281 pH Ultra probe with 1 m cable(89174-024), probe stand, pH 4.01 buffer (red, 500 mL), pH 7.00 buffer (yellow,500 mL), pH 10.01 buffer (blue, 500 mL), and pH storage solution (500 mL).

Lab pH Starter KitCat. No. Description89500-878 Lab pH Starter Kit

Includes: HQ411d benchtop meter, PHC201 pH probe with 1-m cable (89347-984), probe stand, pH 4.01 buffer (red, 500 mL), pH 7.00 buffer (yellow, 500 mL), pH 10.01 buffer (blue, 500 mL), and pH storage solution (500 mL).

Lab Conductivity KitCat. No. Description89500-880 Lab Conductivity Kit

Includes: HQ430d benchtop meter, CDC401 conductivity probe with 1-m cable(89174-028), probe stand, and NaCl conductivity standard (1000 μS/cm, 100 mL).

Lab LBOD KitCat. No. Description89233-214 Lab LBOD Kit

Includes: HQ440d benchtop meter, LBOD101 BOD probe (89174-018), 117 disposable BOD bottles, bottle stoppers (qty 25), and snap-over bottlecaps (qty 24).

Page 11: Vwr - Electrochemistry-meters & Probes

11vwr.com

HQd & IntelliCAL BENCHTOP KITS

Ammonia ISE Measurement KitCat. No. Description89174-062 Ammonia ISE Measurement Kit

Includes: HQ440d benchtop meter, ISENH3181 ammonia electrode with 1-mcable (89174-034), probe stand, ammonia nitrogen standard (1 mg/L, 500 mL)ammonia nitrogen standard (10 mg/L, 500 mL), ammonia nitrogen standard (100 mg/L, 500 mL), ammonia ionic strength adjustor powder pillows (qty 100),and ammonia electrode storage solution (500 mL).

Fluoride ISE Measurement KitCat. No. Description89174-064 Fluoride ISE Measurement Kit

Includes: HQ440d benchtop meter, ISEF121 fluoride electrode with 1-m cable(89174-040), probe stand, fluoride standard (0.5 mg/L, 500 mL), fluoridestandard (1.0 mg/L, 500 mL), fluoride standard (10 mg/L, 500 mL), and ionicstrength adjustor powder pillows (qty 100).

Nitrate ISE Measurement KitCat. No. Description89174-066 Nitrate ISE Measurement Kit

Includes: HQ440d benchtop meter, ISENO3181 nitrate electrode with 1-m cable(89174-042), probe stand, nitrate nitrogen standard (10 mg/L, 500 mL), nitratenitrogen standard (100 mg/L, 500 mL), nitrate nitrogen standard (1000 mg/L,500 mL), and ionic strength adjustor powder pillows (qty 100).

Sodium ISE Starter KitCat. No. Description89174-060 Sodium ISE Starter Kit

Includes: HQ440d benchtop meter, ISENA381 sodium electrode with 1-m cable(89174-032), probe stand, sodium standard solution (10 mg/L, 1 L), sodiumstandard solution (100 mg/L, 1 L), sodium standard solution (1000 mg/L, 500 mL), and ionic strength adjustor powder pillows (qty 100).

Page 12: Vwr - Electrochemistry-meters & Probes

121.800.932.5000

HQd RUGGED FIELD KITS

Rugged LDO/pH/Conductivity Field KitCat. No. Description89174-074 Rugged LDO/pH/Conductivity Field Kit

Includes: HQ40d portable meter, LDO101 rugged dissolved oxygen probe with5-m cable (89174-016), PHC101 rugged pH probe with 5-m cable (89174-026),CDC401 rugged conductivity probe with 5-m cable (89174-030), rugged fieldcase, protective meter glove, PMP erlenmeyer flask (250 mL), samplecontainers (qty 4, 120 mL), wash bottle (500 mL), disposable wipes (qty 280),pH 4.01 buffer solution (singlets, pk/20), pH 7.00 buffer solution (singlets,pk/20), pH 10.01 buffer solution (singlets, pk/20), pH storage solution (50 mL),and NaCl conductivity standard (1000 μS/cm, 100 mL).

Rugged LDO/pH Field KitCat. No. Description89174-076 Rugged LDO/pH Field Kit

Includes: HQ40d portable meter, LDO101 rugged dissolved oxygen probe with5-m cable (89174-016), PHC101 rugged pH probe with 5-m cable (89174-026),rugged field case, protective meter glove, PMP erlenmeyer flask (250 mL),sample containers (qty 4, 120 mL), wash bottle (500 mL), disposable wipes (qty 280), pH 4.01 buffer solution (singlets, pk/20), pH 7.00 buffer solution(singlets, pk/20), pH 10.01 buffer solution (singlets, pk/20), and pH storagesolution (50 mL).

Rugged Conductivity/LDO Field KitCat. No. Description89174-082 Rugged Conductivity/LDO Field Kit

Includes: HQ40d portable meter, LDO101 rugged dissolved oxygen probe with5-m cable (89174-016), CDC401 rugged conductivity probe with 5-m cable(89174-030), rugged field case, protective meter glove, PMP erlenmeyer flask(250 mL), sample containers (qty 4, 120 mL), wash bottle (500 mL), disposablewipes (qty 280), and NaCl conductivity standard (1000 μS/cm, 100 mL).

Rugged ORP/LDO Field KitCat. No. Description89174-080 Rugged ORP/LDO Field Kit

Includes: HQ40d portable meter, LDO101 rugged dissolved oxygen probe with 5-m cable (89174-016), MTC101 rugged ORP probe with 5-m cable(89174-044), rugged field case, protective meter glove, PMP erlenmeyer flask(250 mL), sample containers (qty 4, 120 mL), wash bottle (500 mL), disposablewipes (qty 280), ORP standard solution (Zoebell's, 500 mL) pH storage solution(500 mL), ORP reducing solution (500 mL), and electrode cleaning solution (500 mL).

Rugged LDO Field Kit (w/ HQ40d Meter)Cat. No. Description89174-072 Rugged LDO Field Kit (w/ HQ40d Meter)

Includes: HQ40d portable meter, LDO101 rugged dissolved oxygen probe with 5-m cable (89174-016), rugged field case, protective meter glove, PMP erlenmeyer flask (250 mL), sample containers (qty 4, 120 mL), wash bottle(500 mL), and disposable wipes (qty 280).

Rugged LDO Field Kit (w/ HQ30d Meter)Cat. No. Description89174-070 Rugged LDO Field Kit (w/ HQ30d Meter)

Includes: HQ30d portable meter, LDO101 rugged dissolved oxygen probe with5-m cable (89174-016), rugged field case, protective meter glove, PMPerlenmeyer flask (250 mL), sample containers (qty 4, 120 mL), wash bottle (500mL), and disposable wipes (qty 280).

Page 13: Vwr - Electrochemistry-meters & Probes

13vwr.com

HQd & IntelliCAL PORTABLE KITS

Portable LDO/pH/Conductivity KitCat. No. Description89174-058 Portable LDO/pH/Conductivity Kit

Includes: HQ40d portable meter, LDO101 optical dissolved oxygen probe with1-m cable (89174-014), PHC301 pH probe with 1-m cable (89174-022),CDC401 conductivity probe with 1-m cable (89174-028), probe stand, meterstand, disposable BOD bottle, BOD bottle stoppers, pH 4.01 buffer solution(red, 500 mL), pH 7.00 buffer solution (yellow, 500 mL), pH 10.01 buffer solution(blue, 500 mL), pH storage solution (500 mL), and NaCl conductivity standard(1000 μS/cm, 100 mL).

Portable pH/Conductivity KitCat. No. Description89174-056 Portable pH/Conductivity Kit

Includes: HQ40d portable meter, LDO101 PHC301 pH probe with 1-m cable(89174-022), CDC401 conductivity probe with 1-m cable (89174-028), probestand, meter stand, disposable BOD bottle, BOD bottle stoppers, pH 4.01buffer solution (red, 500 mL), pH 7.00 buffer solution (yellow, 500 mL), pH 10.01buffer solution (blue, 500 mL), pH storage solution (500 mL), and NaClconductivity standard (1000 μS/cm, 100 mL).

Portable pH Starter KitCat. No. Description89233-210 Portable pH Starter Kit

Includes: HQ11d portable meter, PHC201 pH probe with 1-m cable (89347-984),probe stand, meter stand, pH 4.01 buffer solution (red, 500 mL), pH 7.00 buffersolution (yellow, 500 mL), pH 10.01 buffer solution (blue, 500 mL), and pHstorage solution (500 mL).

Portable Conductivity Starter KitCat. No. Description89174-054 Portable Conductivity Starter Kit

Includes: HQ14d portable meter, CDC401 conductivity probe with 1-m cable (89174-028), probe stand, meter stand, and NaCl conductivitystandard (1000 μS/cm, 100 mL).

Portable LBOD KitCat. No. Description89174-068 Portable LBOD Kit

Includes: HQ40d portable meter, LBOD101 optical BOD probe with 1-m cable (89174-018), meter stand, disposable BOD bottle (qty 117), BOD bottle stoppers (qty 25), and BOD bottle caps (qty 24).

Portable LDO KitCat. No. Description89174-050 Portable LDO Kit

Includes: HQ30d portable meter, LDO101 optical dissolved oxygen probe with1-m cable (89174-014), meter stand, disposable BOD bottle, and BOD bottlestoppers.

Page 14: Vwr - Electrochemistry-meters & Probes

Field KitIncludes protective glove and (5) 120mL sample cups. Carry your HQdsystem anywhere. Custom insertsorganize and securely position yourmeter and probes.

141.800.932.5000

HQdMETER & PROBE ACCESSORIES

Universal Probe Stand forStandard Electrode SizesAlso supports Hach IntelliCAL andsensION+ probes.

Cat. No.

89233-220

Meter StandPerfect for use in the laboratory or otherapplications where hands-free meteroperation is desired. Black molded plastic is durable and easy to clean.

Cat. No.

89174-098

Protective GloveProvides added impact protection that fielduse requires. Wrist and neck straps keep themeter secure. Two probe holders (not included in kit) can slide onto glove.

Cat. No.

89174-100

Color Coded Probe ClipsClip a color-coded band to each end of your probe cable for identification. Ten clips of five different colors per package.

NOTE: One package of clips included with each probe.

Cat. No.

89174-104

Cat. No.

89174-106

HQd Field Meter Protective CapsFurther protect your HQd meter from harsh (corrosive) field environments. For use with HQd Meter Protective Glove kit (89174-100).

Cat. No.

89233-218

Probe Holder (Standard IntelliCAL Probes Only)For use with the Protective Glove. Simply wrap1- or 3-meter cables around the holder and slideprobe into protective sheath. Protective Glovecan hold one or two Probe Holders.

Cat. No.

89174-110

Probe Cable Depth MarkersTaking reading at specific depths withrugged probes is a snap with these DepthMarkers. Visually identify the depth ofyour probe by attaching Depth Markersecurely on cable at points to meet yourneeds. Five Depth Markers per package.

NOTE: For use with rugged probes only.Cat. No.89500-850

Cat. No.

89174-094Probes and Meter not included.

Shroud Kit(Probe not included.)

Rugged Field Case for TwoProbes with 5-m CablesIncludes: Empty case and insert for meterand probe storage; (4) Containers forsample collection; 500 mL Wash Bottle.

Cat. No.89174-084

Rugged Field Case for Three Probes with 5-m CablesIncludes same accessories as case 89174-084.

Cat. No.89174-086

Replacement Shroud Kit for Rugged ProbesIncludes protective bell and locking ring. The rugged shroud absorbsthe impact from rough wear and tear.

Page 15: Vwr - Electrochemistry-meters & Probes

15vwr.com

Parameter

PH1BASIC

PORTABLEpH METER

MM110PORTABLE

MULTI-METER

EC5PORTABLE

CONDUCTIVITYMETER

DO6PORTABLEDISSOLVED

OXYGEN METER

MM150PORTABLE

MULTI-METER Temperature pH Conductivity Salinity TDS Dissolved Oxygen ORP/Redox

Specifications

PH1BASIC

PORTABLEpH METER

MM110PORTABLE

MULTI-METER

EC5PORTABLE

CONDUCTIVITYMETER

DO6PORTABLEDISSOLVED

OXYGEN METER

MM150PORTABLE

MULTI-METER IP Rating IP67 IP67 IP67 IP67 IP67Internal Data Storage — — — — —Resolution 0.01 pH

0.1 mV (±199.9 mV range)

0.01 pH1 mV

EC: 0.01 μS/cm - 1 mS/cm

TDS: 1mg/L - 1g/Ldepending on range

Salinity: 0.1 mg/L - 0.1 g/L depending

on range

0.01 mg/L pH: 0.01ORP: 1 mV

EC: 0.01 μS/cm - 1 mS/cm depending

on range1 mg/L - 1 g/L

depending on rangeInputs MP-5 MP-8 MP-5 MP-5 MP-8Outputs — — — — —Interface Languages Icon based,

no language neededIcon based,

no language neededIcon based,

no language neededIcon based,

no language neededIcon based,

no language neededWarranty 3 years 3 years 3 years 3 years 3 yearsCompliance CE.WEEE CE.WEEE CE.WEEE CE.WEEE CE.WEEEMeasurement Method Auto stabilization,

manualAuto stabilization,

manualAuto stabilization,

manualAuto stabilization,

manualAuto stabilization,

manualPC Data Transfer Software — — — — —Backlight Battery Requirements 3, AA 3, AA 3, AA 3, AA 3, AA

Cat. No. 89174-186 89174-190 89174-184 89231-218 89174-192

See pages 20-21 for sensION+ Meter & Probe Kits. See page 22 for sensION+ Accessories.

sensION+ PORTABLE METERS

sensION+ FIELD KITS work ascomplete mobile measurementstations with everything youneed to start testing.

Screw-on calibration tubessimplify on-site calibration and minimize consumption of standard solutions.

Page 16: Vwr - Electrochemistry-meters & Probes

Parameter

PH3BASIC

BENCHTOPpH METER

PH31GLP

BENCHTOPpH METER

EC7BENCHTOP

CONDUCTIVITYMETER

EC71GLP

BENCHTOPCONDUCTIVITY

METER

MM340BENCHTOPMULTI-

PARAMETERMETER

MM374BENCHTOPMULTI-

PARAMETERMETER

Temperature pH mV Conductivity Salinity TDS ORP/Redox Ammonia Nitrate Fluoride Sodium Chloride Ammonium

Specifications

PH3BASIC

BENCHTOPpH METER

PH31GLP

BENCHTOPpH METER

EC7BENCHTOP

CONDUCTIVITYMETER

EC71GLP

BENCHTOPCONDUCTIVITY

METER

MM340BENCHTOPMULTI-

PARAMETERMETER

MM374BENCHTOPMULTI-

PARAMETERMETER

IP Rating IP42 IP42 IP42 IP42 IP42 IP42Internal Data Storage — 330 - 400 330 330Resolution pH: 0.01

ORP: 1 mVpH: 0.001

ORP: 0.1 mVEC: 0.01 μS/cm

- 1 mS/cmdepending on rangeSalinity: Dependent

on range

EC: 0.01 μS/cm - 1 mS/cm

depending on rangeTDS: 1 mg/L - 1 g/LSalinity: Dependent

on range

pH: 0.001ORP 0.1 mV

pH: 0.001 pHORP: 0.1 mV

EC: 0.01 μS/cm - 1 mS/cm

depending on rangeTDS: 1 mg/L - 1 g/LSalinity: Dependent

on rangeInputs BNC, ref,

Pt1000BNC, ref,Pt1000

E.C. cell,Pt1000

E.C. cell,Pt1000

2 BNC,2 ref, Pt1000

2 BNC,2 ref, 1 E.C.

Outputs RS232*(two-way)

RS232*(two-way)

RS232*(two-way)

RS232*(two-way)

Interface Languages 6** 6** 6** 6** 6** 6**Warranty 3 years 3 years 3 years 3 years 3 years 2 yearsCompliance CE.WEEE CE.WEEE CE.WEEE CE.WEEE CE.WEEE CE.WEEEGLP Features — — PC Data Transfer Software Backlight AC and USB Operation

Cat. No. 89174-172 89174-174 89174-178 89174-180 89174-176 89174-182

161.800.932.5000

sensION+ BENCHTOP METERS

Each system is designed to be used in a wide variety ofapplications and comescomplete with everything you need to start testing.

See pages 20-21 for sensION+ Meter & Probe Kits. See page 22 for sensION+ Accessories.

*USB compatibility with optional adapter. **English, German, Spanish, French, Italian, and Portuguese

Page 17: Vwr - Electrochemistry-meters & Probes

SpecificationspH Combination

Gel-filled

pH CombinationSolid Gel

Wastewater

pH CombinationLow ConductivityHigh Temperature

ORP / RedoxCombinationGel-filled

Special Feature With Working Protector. Solid gel for high solids

content.

With Working Protector. For low ionic strength

and/or high temperature.Range 0 to 14 pH 2 to 14 pH 0 to 14 pH ± 2000 mVAccuracy 0.02 pH with pH1 Meter 0.02 pH with pH1 Meter 0.02 pH with pH1 Meter 1 mV with pH1 MeterTemperature Range 0 to 80 °C 0 to 80 °C 0 to 100 °C 0 to 80 °C

Thermistor Pt1000 Pt1000 Pt1000 -Dimensions (D x L) 0.47 in x 3.35 in

(12 mm x 85 mm)0.47 in x 3.35 in

(12 mm x 85 mm)0.47 in x 3.35 in

(12 mm x 85 mm)0.47 in x 3.35 in

(12 mm x 85 mm)Sensor Type Glass Glass Glass Platinum

annular ring

Junction Ceramic pin Open Porous annular PTFE Ceramic pinMaterial Sensor Body: Polycarbonate Sensor Body:

GlassSensor Body:

GlassSensor Body: Polycarbonate

Filling Solution Non-refillable gel

Non-refillable solid polymer

Non-refillable gel

Non-refillable gel

Cat. No. 89174-216 89174-218 89174-220 89174-226

Specifications Conductivity Conductivity Multi

Combination**Multi

Combination*Multi

Combination**Special Feature For harsh samples pH, Conductivity, ORP pH, ORP pH, ConductivityRange 0.2 µS/cm to 200 mS/cm 5 µS/cm to 50 mS/cm pH: 0 to 14 pH pH: 0 to 14 pH pH: 0 to 14 pH

Conductivity: 20 µS/cm to 200 mS/cm

Conductivity: 20 µS/cm to 200 mS/cm

ORP:± 2000 mV ORP: ± mVAccuracy 0.50% with EC5 Meter 0.50% with EC5 Meter 0.02 pH with

MM150 Meter1 mV with MM150 Meter

0.50% EC with MM150 Meter

0.02 pH with MM110 Meter

1mV with MM110 Meter

0.02 pH with MM150 Meter0.50% EC with MM150 Meter

Temperature Range 0 - 80 °C 0 to 80 °C 0 to 80 °C 0 to 80 °C 0 to 80 °CThermistor Pt1000 Pt1000 Pt1000 Pt1000 Pt1000Dimensions (D x L) 0.47 in x 3.35 in

(12 mm x 85 mm)0.47 in x 3.35 in

(12 mm x 85 mm)0.47 in x 3.35 in

(12 mm x 85 mm)0.47 in x 3.35 in

(12 mm x 85 mm)0.47 in x 3.35 in

(12 mm x 85 mm)Sensor Type 3-pole Platinum,

k = 1.0 cm-12-pole Titanium,

k = 0.3 cm-1pH: Glass

ORP: PlatinumConductivity: Platinum

pH: GlassORP: Platinum

pH: GlassConductivity: Platinum

Junction Ceramic Ceramic CeramicMaterial Sensor Body:

Outside: Polycarbonate;Inside: Glass

Sensor Body: Titanium

Sensor Body:Polycarbonate

Sensor Body:Polycarbonate

Sensor Body:Polycarbonate

Filling Solution — — Non-refillable gel Non-refillable gel Non-refillable gel

Cat. No. 89174-222 89174-224 89174-212 89174-210 89174-214

17

sensION+ PROBES FOR PORTABLE METERS

*Only for use on MM110 Meter. **Only for use with MM150 Meter.

vwr.com

Page 18: Vwr - Electrochemistry-meters & Probes

SpecificationspH Combination

Gel-filled pH Combination

Refillable

pH CombinationGel-filled

WastewaterpH Combination

Refillable Special Feature TRIS compatible Solid gel

for high solids contentClog-free Sleeve Junction

for low ionic strength.Range 0 to 14 pH 0 to 14 pH 2 to 14 pH 0 to 14 pHAccuracy 0.02 pH with pH3 Meter

0.002 pH with pH31 Meter0.002 pH with MM340 Meter0.002 pH with MM374 Meter

0.02 pH with pH3 Meter0.002 pH with pH31 Meter

0.002 pH with MM340 Meter0.002 pH with MM374 Meter

0.02 pH with pH3 Meter0.002 pH with pH31 Meter

0.002 pH with MM340 Meter0.002 pH with MM374 Meter

0.02 pH with pH3 Meter0.002 pH with pH31 Meter

0.002 pH with MM340 Meter0.002 pH with MM374 Meter

Temperature Range 0 to 80 °C -10 to 100 °C 0 to 80 °C 0 to 60 °CThermistor Pt1000 Pt1000 Pt1000 Pt1000Dimensions (D x L) 0.47 in x 5.12 in

(12 mm x 130 mm)0.47 in x 5.12 in

(12 mm x 130 mm)0.47 in x 5.12 in

(12 mm x 130 mm)0.47 in x 5.12 in

(12 mm x 130 mm)Sensor Type Glass Glass Glass GlassJunction Ceramic pin 2 x Ceramic pin Open Open with sleeveMaterial Sensor Body: Polycarbonate Sensor Body: Glass Sensor Body: Glass Sensor Body: GlassFilling Solution Non-refillable gel 89174-440 Non-refillable solid polymer 89174-440

Cat. No. 89174-194 89174-198 89174-196 89174-200

Specifications ConductivityORP

Gel-filled Combination ORP

Refillable Combination Special FeatureRange 0.2 µS/cm to 200 mS/cm ± 2000 mV ± 2000 mVAccuracy 0.50% EC & TDS 1mV with pH3 Meter

0.2mV with pH31 Meter0.2mV with MM340 Meter0.2mV with MM374 Meter

1mV with pH3 Meter0.2mV with pH31 Meter

0.2mV with MM340 Meter0.2mV with MM374 Meter

Temperature Range 0 to 80 °C 0 to 80 °C 0 to 80 °CThermistor Pt1000 — —Dimensions (D x L) 0.47 in x 5.12 in (12 mm x 130 mm) 0.47 in x 5.12 in (12 mm x 130 mm) 0.47 in x 5.12 in (12 mm x 130 mm)Sensor Type 3-pole Platinum, k = 0.7 cm-1 Platinum PlatinumJunction — Ceramic pin Ceramic pinMaterial Sensor Body:

Outside: Polycarbonate; Inside: GlassSensor Body:

GlassSensor Body:

GlassFilling Solution — Non-refillable gel 89174-440

Cat. No. 89174-206 89174-202 89174-204

181.800.932.5000

sensION+ PROBES FOR BENCHTOP METERS

Page 19: Vwr - Electrochemistry-meters & Probes

SpecificationsNitrate

Combination ISEAmmonia

Combination ISE ReferenceElectrode

Special Feature Combination electrode Maintenance free:No electrolyte or spare membranes needed

Gas Sensing Electrode

Double junction reference electrode for ISEs, large ceramic diaphragm

Ranges 0.1 mg/L to 14,000 mg/L NO3- 0.06 mg/L to 17,000 mg/L NH3 —

Accuracy ±0.02 mV or 0.05%, whichever is greater(application dependent)

— —

Temperature Range 5 to 50 °C 0 to 50 °C 0 to 60 °CDimensions (D x L) 0.47 in x 4.72 in (12 mm x 120 mm) 0.47 in x 5.87 in (12 mm x 149 mm) 0.47 in x 4.72 in (12 mm x 120 mm)Sensor Type Solid-state

PVC membraneGas sensing: glass w/ replaceable

NH3 sensitive membrane—

Junction Porous Teflon Annular Ring Porous Teflon Annular Ring CeramicMaterial Sensor Body: Epoxy Sensor Body: ABS Sensor Body: GlassFilling Solution Non-refillable driTEK gel 97021-474 —ISA Required 89173-992 97021-772 —

Cat. No. 89501-156 97021-576 89174-228

19vwr.com

sensION+ ISE PROBES

SpecificationsSodium

ISEChloride

Combination ISEFluoride

Combination ISESpecial Feature Combination electrode

Maintenance free: No electrolyte or spare membranes needed

Combination electrode Maintenance free: No electrolyte

or spare membranes neededRanges 0.05 - 23,000 mg/L Na+ 0.1 mg/L to 35,500 mg/L Cl- 0.01 mg/L to 19,000 mg/L F-

Accuracy ±0.02 mV or 0.05%, whichever is greater(application dependent)

±0.02 mV or 0.05%, whichever is greater(application dependent)

±0.02 mV or 0.05%, whichever is greater(application dependent)

Temperature Range 0 to 60 °C 5 to 50 °C 5 to 50 °CDimensions (D x L) 0.47 in x 4.72 in

(12 mm x 120 mm)0.47 in x 4.72 in

(12 mm x 120 mm)0.47 in x 4.72 in

(12 mm x 120 mm)Sensor Type Sodium Selective

Glass MembraneSolid-state

crystal membraneSolid-state

crystal membraneJunction — Porous Teflon Annular Ring Porous Teflon Annular RingMaterial Sensor Body: Glass Sensor Body: Epoxy Sensor Body: EpoxyFilling Solution — Non-refillable driTEK gel Non-refillable driTEK gelISA Required 97021-782 89173-988 97021-786

Cat. No. 89174-230* 89501-152 89501-154

*The ISE electrodes are indicator and require a reference electrode.

Page 20: Vwr - Electrochemistry-meters & Probes

• sensION+ Benchtop meters are available in popular packaged configurations

• Choose from basic kits or advanced kits for your lab testing needs

• Unique design developed as a complete workstation including integrated stirrer, probe stand, calibration flasks, and compartments for essentiallab work

• All benchtop kits include: workstation with integrated stirrer, buIers, standards, storage solutions, calibration flasks, and accessories for quick start up

201.800.932.5000

sensION+ BENCHTOP METER & PROBE KITS

Cat. No. Description

89174-122 Basic pH (general) Benchtop KitsensION+ PH3 meter with universal 5010T pH and temperatureelectrode (89174-194). For general aqueous applications.

89174-126 Advanced pH (dirty samples) Benchtop KitsensION+ PH3 meter with open junction 5011T pH and temperatureelectrode (89174-196). For high solid content and/or viscous mediasamples.

89174-124 Advanced pH (high performance) Benchtop KitsensION+ PH3 meter with dual junction 5014T pH and temperatureelectrode (89174-198). For sulfurs, reducing sugars or media that reactswith Ag+ ions.

89174-128 Advanced pH (difficult samples) Benchtop KitsensION+ PH3 meter with clog-free 5021T pH and temperatureelectrode (89174-200). For low ionic strength, colloidal, emulsions andcream samples.

89174-130 Basic pH (general) Benchtop KitsensION+ PH31 GLP meter with universal 5010T pH and temperatureelectrode (89174-194). For general aqueous applications.

89174-134 Advanced pH (general) Benchtop KitsensION+ PH31 GLP meter with open junction 5011T pH andtemperature electrode (89174-196). For high solid content and/orviscous media samples

89174-132 Advanced pH (high performance) Benchtop KitsensION+ PH31 GLP meter with dual junction 5014T pH andtemperature electrode (89174-198). For sulfurs, reducing sugars ormedia that reacts with Ag+ ions.

89174-136 Advanced pH (difficult samples) Benchtop KitsensION+ PH31 GLP meter with clog-free 5021T pH and temperatureelectrode (89174-200). For low ionic strength, colloidal, emulsions andcream samples.

89174-142 Basic pH (general) Benchtop KitsensION+ MM340 pH & ISE GLP meter with universal 5010T pH andtemperature electrode (89174-194). For general aqueous applications.

89174-146 Advanced pH (dirty samples) Benchtop KitsensION+ MM340 pH & ISE meter with open junction 5011T pH andtemperature electrode (89174-196). For high solid content and/orviscous media samples.

89174-144 Advanced pH (high performance) Benchtop KitsensION+ MM340 pH & ISE GLP meter with dual junction 5014T pHand temperature electrode (89174-198). For sulfurs, reducing sugars ormedia that reacts with Ag+ ions.

89174-148 Advanced pH (difficult samples) Benchtop KitsensION+ MM340 pH & ISE GLP meter with clog-free 5021T pH andtemperature electrode (89174-200). For low ionic strength, colloidal,emulsions and cream samples.

89174-138 Basic Conductivity Benchtop KitsensION+ EC7 meter with universal 5070 conductivity and temperaturecell (89174-206). For general aqueous applications.

89174-140 Advanced Conductivity Benchtop KitsensION+ EC71 GLP meter with universal 5070 conductivity andtemperature cell (89174-206). For general aqueous applications.

89174-150 Advanced pH (high performance) & Conductivity Benchtop KitsensION+ MM374 pH, conductivity & ISE GLP meter with dual junction5014 pH and universal 5070 conductivity with temperature cell (89174-206). For sulfurs, reducing sugars or media that reacts with Ag+ ions.

Page 21: Vwr - Electrochemistry-meters & Probes

Cat. No. Description

89174-156 Basic pH (general) Field KitsensION+ PH1 meter with universal 5050T pH and temperatureelectrode (89174-216). For general aqueous applications.

89174-158 Advanced pH (dirty samples) Field KitsensION+ PH1 meter with open junction 5051T pH and temperature electrode (89174-218). For high solid content and/orviscous media samples.

89174-160 Advanced pH (difficult samples) Field KitsensION+ PH1 meter with high contact 5052T pH and temperatureelectrode (89174-220). For low ionic strength, colloidal, emulsions andcream samples.

89174-162 Basic ORP Field KitsensION+ PH1 meter with 5055 ORP electrode (89174-226). Forchemical waste treatment, galvanic baths and general aqueous applications.

89174-152 Basic Conductivity Field KitsensION+ EC5 meter with universal 5060 conductivity and temperature cel (89174-222)l. For general aqueous applications.

89174-154 Advanced Conductivity Field KitsensION+ EC5 meter with robust, Titanium 5062 conductivity andtemperature cell (89174-224). For difficult media applications.

89174-166 Basic Dissolved Oxygen Field KitsensION+ DO6 meter with robust, polarographic 5120 DO andtemperature probe (89174-208). For general aqueous applications.

89174-164 Advanced pH & ORP Multi-sensor Field KitsensION+ MM110 meter with 5045 pH, ORP and temperature multi-sensor (89174-210). For general aqueous applications.

89174-168 Advanced pH and Conductivity Multi-sensor Field KitsensION+ MM150 meter with 5059PT pH, conductivity and temperature multi-sensor (89174-214). For agriculture and generalaqueous applications.

89174-170 Advanced pH, Conductivity & ORP Multi-sensor Field KitsensION+ MM150 meter with 5048 pH, conductivity, ORP andtemperature multi-sensor (89174-212). For waste treatment and generalaqueous applications.

21vwr.com

sensION+ FIELD KITS

• sensION+ meters are available in popular packaged configurations

• Choose from basic, advanced, or multi-sensor kits for your field testing needs

• Specialized field carrying case acts as a portable laboratory

• All field kits include: meter, sensor, field carrying case, buIers, standards, storage solutions,calibration tubes with screw caps, and accessories for quick start up

Page 22: Vwr - Electrochemistry-meters & Probes

Cat. No. Description

89174-378 Thermal printer, RS232, for sensION+ benchtop

89174-408 Thermal paper for printer 89174-378,bag with 5 rolls

89174-410 Dot-impact printer, RS232, for sensION+ instruments

89174-412 Standard paper for printer 89174-410,bag with 10 rolls

89174-414 Ribbon for printer 89174-410, 3 units.

89174-416 RS232 cable, for sensION+ benchtop instruments

89174-418 RS232 cable for sensION+ benchtop,with USB adapter

89174-380 Magnetic stirrer with sensor holder, for sensION MM benchtop

89174-386 Holder and clamp for one sensor, for portable sensION+

89174-388 3x10 mL printed tubes, for portable pH calibration

89174-390 3x10 mL printed tubes, for portableconductivity calibration

89174-392 Spare membrane for D.O. electrode 89174-394

97021-612 Spare membranes for 5130 DOelectrode, 2/pk

89501-144 Protector-calibration flask for D.O.electrode, light version

89501-150 Radiometer sensor holder for sensION+benchtop instruments, for three sensors,includes 89501-202 sockets

89174-398 Three-sensor holder, for sensION+benchtop instruments

89174-382 3x50 mL printed flasks for benchtop pH calibration

89174-384 3x50 mL printed flasks for benchtopconductivity calibration

89174-400 Holder and clamp for three sensors,sensION+

89174-402 Pyrex glass chamber, continuous flowmeasurements, sensION+

89174-404 PP protector, electrode storage,sensION+

89174-406 PP protector, for measurement,sensION+

89233-222 Hach LabCom Easy Software,sensION+, GLP

89233-224 Hach LabCom Software, sensION+, GLP

89174-460 Ammonia Membrane Replacement Kit,5/pk

221.800.932.5000

sensION+ ACCESSORIES

Cat. No. Description

Thermal printer, RS232, for sensION+ benchtop Hach LabCom Easy Software, sensION+, GLP

Page 23: Vwr - Electrochemistry-meters & Probes

23vwr.com

H-SERIES PORTABLE METERS

See page 27 for H-Series Bundles & Accessories.

Dual-technology meters take readingsfrom non-glass pH and traditional probesacross multiple parameters. Available withoptional data management, Bluetooth®,and ISE capabilities.

Parameter

H160WATERPROOFPORTABLEMETER

H160GWATERPROOFPORTABLEMETER

H170WATERPROOFPORTABLEMETER

H170GWATERPROOFPORTABLEMETER

Temperature Dual pH technology

GlassNon-glass (ISFET)

mV Conductivity TDS Salinity ResistivityDissolved Oxygen (Galvanic)ORP/Redox Ammonia Nitrate Fluoride Sodium

Feature

H160WATERPROOFPORTABLEMETER

H160GWATERPROOFPORTABLEMETER

H170WATERPROOFPORTABLEMETER

H170GWATERPROOFPORTABLEMETER

IP Rating IP67 IP67 IP67 IP67Internal data storage — 999 — 999Inputs BNC (1), 3.5 mm

phone (1), 8-pinWaterproof ISFET pH (1)

BNC (1), 3.5 mmphone (1), 8-pin

Waterproof ISFET pH (1)

BNC (1), 3.5 mmphone (1), 8-pin

Waterproof ISFET pH (1), 12-pinWaterproof conductivity (1)

BNC (1), 3.5 mmphone (1), 8-pin Waterproof

ISFET pH (1), 12-pinWaterproof conductivity (1)

Outputs — Bluetooth — BluetoothInterface languages English English English English Warranty 3 years 3 years 3 years 3 yearsCompliance CE.WEEE CE.WEEE.IC.FCC CE.WEEE CE.WEEE.IC.FCCGLP features — — PC Data Transfer Software — Included — Included Backlight Battery Operation AC and USB operation — — — —

Cat. No. 89214-852 89214-856 89214-860 89214-864

Page 24: Vwr - Electrochemistry-meters & Probes

241.800.932.5000

See page 27 for H-Series Bundles & Accessories.

H-SERIES BENCHTOP METERS

Parameter

H260GBENCHTOPMETER

H260GBBENCHTOPMETER

H270GBENCHTOPMETER

H280GBENCHTOPMETER

Temperature Dual pH technology

GlassNon-glass (ISFET)

mV Conductivity TDS Salinity ResistivityDissolved Oxygen (Galvanic) ORP/Redox Ammonia Nitrate Fluoride Sodium

Feature

H260GBENCHTOPMETER

H260GBBENCHTOPMETER

H270GBENCHTOPMETER

H280GBENCHTOPMETER

IP Rating IP42 IP42 IP42 IP42Internal data storage 999 999 999 999Inputs BNC (1), 3.5 mm

phone (1), 4 mmreference (1), 8-pinRJ-45 ISFET pH (1)

BNC (1), 3.5 mmphone (1), 4 mm

reference (1), 8-pinRJ-45 ISFET

pH (1)

BNC (1), 3.5 mmphone (1), 4 mm

reference (1), 8-pinRJ-45 ISFET pH(1), 12-pin waterproofConductivity (1)

BNC (1), 3.5 mmphone (1), 4 mm

reference (1), 8-pinRJ-45 ISFET pH (1), 12-pin Waterproof

Conductivity (1)

Outputs USB to PC USB to PCBluetooth

USB to PC USB to PC

Interface languages English English English English Warranty 3 years 3 years 3 years 3 yearsCompliance CE.WEEE CE.WEEE.IC.FCC CE.WEEE CE.WEEEGLP features PC Data Transfer Software Included Included Included IncludedBacklight Battery Operation AC and USB operation Included Included Included Included

Cat. No. 89216-868 89501-088 89174-872 89214-876

Benchtop models include GLP-relatedfeatures and optional Bluetooth®

communication.

Page 25: Vwr - Electrochemistry-meters & Probes

25vwr.com

Continued on next page.

Specifications

pHNMR Tube Micro Probe

Combination

pHPiercing Tip Micro Probe

Combination (Heavy-Duty Handle) Special Feature Ideal for 5 mm NMR tubes

or long-reach applications.Great for heavy-duty piercing applications.

Ranges 0 to 14 pH 0 to 14 pH Temperature Range 0 - 60 °C 0 - 60 °CThermistor (ATC) (ATC)Dimensions (D x L) 0.15 in x 8.66 in (3.8 mm x 220 mm) 0.19 in x 3.54 in (4.8 mm x 90 mm)Sensor Type ISFET ISFETJunction Fiber FiberMaterial Sensor Body: Stainless Steel Sensor Body: Stainless SteelFilling Solution — —Waterproof Connector(for portable meters)

82026-956 82026-958

Cat. No. 14221-756 82007-538

Specifications

pHGeneral Purpose

Round Tip Combination

pHMicro ProbeCombination

pHPiercing Tip Micro Probe

Combination Special Feature Virtually indestructible

for general applications.Great for small sample sizes,

flasks and test tubes.Great for light-duty

piercing applications.Ranges 0 to 14 pH 0 to 14 pH 0 to 14 pH Temperature Range 0 - 60 °C 0 - 60 °C 0 - 60 °CThermistor (ATC) (ATC) (ATC)Dimensions (D x L) 0.33 in x 5.51 in (8.3 mm x 140 mm) 0.19 in x 5.12 in (4.8 mm x 130 mm) 0.19 in x 3.54 in (4.8 mm x 90 mm)Sensor Type ISFET ISFET ISFETJunction Fiber Fiber FiberMaterial Sensor Body: Stainless Steel Sensor Body: Stainless Steel Sensor Body: Stainless SteelFilling Solution — — —Waterproof Connector(for portable meters)

82026-950 82026-952 82026-954

Cat. No. 82007-534 14221-752 14221-754

H-SERIES PROBES

Non-glass pH probes: • Virtually indestructible• Store dry• Extended shelf life• Easy maintenance and cleaning

Page 26: Vwr - Electrochemistry-meters & Probes

261.800.932.5000

SpecificationsORP/Redox Combination

Standard Gel-Filled pH

Combination pH CombinationPlatinum Series

pH CombinationRefillable

Special FeatureRange ± 1999 mV 0 - 14 pH 0 - 14 pH 0 - 14 pHTemperature Range -10 - 110 °C 0 - 45 °C 0 - 45 °C 0 - 45 °CThermistor — — — —Dimensions (D x L) 0.47 in x 4.33 in

(12 mm x 110 mm)0.48 in x 6 in

(12.1 mm x 152.5 mm)0.5 in x 9.49 in

(12.7 mm x 241 mm)0.48 in x 6 in

(12.1 mm x 152.5 mm)Sensor Type Platinum annular ring Glass Glass GlassJunction Ceramic pin Glass frit Open Glass fritMaterial Sensor Body: Epoxy Sensor Body: Epoxy Sensor Body: Epoxy Sensor Body: EpoxyFilling Solution Non-refillable gel Non-refillable gel 97021-774 97021-734Waterproof Connector(for portable meters)

— — —

Cat. No. 82020-480 97021-580 97021-596 97021-604

SpecificationsConductivityBull's-Eye Conductivity Conductivity Dissolved Oxygen

Special Feature Drinking water applications High salinity applications.Range 5 µS/cm - 1 mS/cm 1 mS/cm - 200 mS/cm 10 µS/cm - 2 mS/cm 0 - 20 mg/LTemperature Range -10 - 110 °C -10 - 110 °C -10 - 110 °C 0 - 50 °CThermistor (ATC) (ATC) (ATC) (ATC)Dimensions (D x L) 0.63 in x 4.33 in

(16 mm x 110 mm)0.47 in x 4.33 in

(12 mm x 110 mm)0.47 in x 4.33 in

(12 mm x 110 mm)0.47 in x 4.33 in

(12 mm x 110 mm)Sensor Type 4-pole graphite 4-pole platinum 4-pole platinum MembraneJunction — — — —Material Sensor Body:

EpoxySensor Body:

GlassSensor Body:

EpoxySensor Body:

Polycarbonate / AbsFilling Solution — — — —Waterproof Connector(for portable meters)

Cat. No. 82026-962 82026-960 82026-966 97006-530

H-SERIES PROBES

Page 27: Vwr - Electrochemistry-meters & Probes

27vwr.com

H-SERIES BUNDLES

Cat. No. Description

89214-870 H260G meter with PH77-SS ISFET pH Probe(82007-534), USB Cord, AC Adapter, andSmartLogger II Software, PLUS consumables.

89501-086 H260G Bluetooth meter with PH77-SS ISFET pHProbe (82007-534), Calibrating Buffer Kit, USBCord, AC Adapter, and SmartLogger II Software,PLUS consumables.

89214-874 H270G meter with PH77-SS ISFET pH Probe(82007-534), CDW97-KP5 Conductivity Probe(82026-962), USB Cord, AC Adapter, andSmartLogger II Software, PLUS consumables.

89501-090 H270G Bluetooth meter with PH77-SS ISFET pHProbe (82007-534), CDW97-KP5 ConductivityProbe (82026-962), Calibrating Buffer Kit, USBCord, AC Adapter, and SmartLogger II Software,PLUS consumables.

89214-878 H280G meter with PH77-SS ISFET pH Probe(82007-534), CDW97-KP5 Conductivity Probe(82026-962), DO50-GS Dissolved Oxygen Probe(97006-530), USB Cord, AC Adapter, andSmartLogger II Software, PLUS consumables.

89501-092 H280G Bluetooth meter with PH77-SS ISFET pHProbe (82007-534), CDW97-KP5 ConductivityProbe (82026-962), DO50-GS Dissolved Oxygen,USB Cord, AC Adapter, SmartLogger II Software,PLUS consumables.

89214-854 H160-77 meter & PHW77-SS pH Probe (82007-534), Field Case & Calibration Kit; Rubber Holster,PLUS consumables.

89214-858 H160G Bluetooth Meter, PHW77-SS ISFET Probe(82007-534), Field Carrying Case & Calibration Kit,Rubber Holster, and SmartLogger II Software, PLUSconsumables.

89214-862 H170 Meter, PHW77-SS pH Probe (82007-534) &CDW97-KP5 Conductivity Probe (82026-962), FieldCase & Calibration/Standards Kit, and RubberHolster, PLUS consumables.

89214-866 H170G Bluetooth Meter, PHW77-SS pH Probe(82007-534), CDW97-KP5 Conductivity Probe(82026-962), Field Case & Calibration/StandardsKit, Rubber Holster, and SmartLogger II Software,PLUS consumables.

Cat. No. Description

H-SERIES ACCESSORIES

Universal Probe Stand

Cat. No. Description97011-954 Easy-to-thread-on cap with a pre-installed membrane97011-956 Includes the DO50-CAP plus a small bottle of electrolyte and a

syringe to add the electrolyte to the sensor. There is enoughelectrolyte to refill 3 caps.

89233-226 SmartLogger II Software CD89233-220 Universal Probe Stand for Standard Electrode Sizes

Also supports Hach IntelliCAL and sensION+ probes.89214-850 Replacement Reference Electrode for the H130, H135 & H13814221-746 Replacement Reference Electrode for miniLab Models

Page 28: Vwr - Electrochemistry-meters & Probes

281.800.932.5000

miniLAB® POCKET PH METERS

When you don’t want the hassle of a probe but still need a non-glass pH meter.

Feature

H130miniLABPOCKETpH METER

H135miniLABPOCKETpH METER

H138miniLABPOCKETpH METER

IP Rating IP67 IP67 IP67Internal data storage — — —Inputs — — —Outputs — — —Interface languages English English EnglishWarranty 1 year 1 year 1 yearCompliance CE.WEEE CE.WEEE CE.WEEEGLP features — — —PC Data Transfer Software — — —Backlight — — —Battery Operation 2, 3V (CR2032) 2, 3V (CR2032) 2, 3V (CR2032)AC and USB operation — — —

Cat. No. 89214-844 89214-846 89214-848

Specifications

H130miniLABPOCKETpH METER

H135miniLABPOCKETpH METER

H138miniLABPOCKETpH METER

Temperature (ATC) (ATC) (ATC)Sensor ISFET silicon chip pH sensorCalibration 1-Point 1-, 2-, or 3-pointBuffer Recognition pH 7.00

pH 6.86pH 4.01, 7.00, and 10.01pH 4.01, 6.86, and 9.18

Reference Replaceable KCl gel filled (9316900)pH Range Suggested range: 5.0 to 9.0 pH

2.0 to 12.0 pH2.0 to 12.0 pH

Resolution 0.1 pH 0.01 pHInput Accuracy ≤0.1 pH ≤0.01 pHRepeatability ± 0.1 pH ± 0.03 pHDisplay LCD LCD with TemperatureOperation Temp. Range Range: 5 to 40ºC; AutomaticBattery Operation Two 3v lithium batteries (CR2032) includedBattery Life Up to 200 hours continuous warning with 10 hour advance low battery and automatic power offDimensions 155 x 33 x 20 mm (6 1/8" L x 1 1/4" W x 3/4" H) Weight 77 g (0.17 lbs.) -meter only

Page 29: Vwr - Electrochemistry-meters & Probes

29vwr.com

POCKET PRO TESTERS

SpecificationsPocket Pro TDS LR

Pocket Pro TDS HR

Pocket Pro Conductivity LR

Parameter TDS, Temp TDS, Temp Conductivity, TempOperating Temperature Range

0 to 50ºC 0 to 50ºC 0 to 1990 µS/cm

Range 0 to 1999 ppm 0 to 10.00 ppt 0 to 1999 ppmAccuracy 1% FS 2% FS 1% FSResolution 1 ppm 0.01 ppt 1 µS/cmTDS Factor adjustable; 0.71 default adjustable; 0.71 default —Battery Requirements 4 AAA 4 AAA 4 AAAIP Rating IP67 IP67 IP67Backlight — — —

Prod. No. 89508-360 89508-362 89508-364

SpecificationsPocket Pro

Conductivity HRPocket Pro

SaltPocket Pro Temperature

Parameter Conductivity, Temp Salinity, Temp TemperatureOperating Temperature Range

0 to 50ºC 0 to 50ºC 0 to 50ºC

Range 0.0 to 19.99 mS/cm 0 to 10.00 ppt -15 to 170°CAccuracy 2% FS 1% FS 1°CResolution 0.01 mS/cm 0.01 ppt 0.1°CTDS Factor — — —Battery Requirements 4 AAA 4 AAA 4 AAAIP Rating IP67 IP67 IP67Backlight — — —

Cat. No. 89508-366 89508-368 89508-37089508-372 is replacement sensor for

Pocket Pro Temp

Take the guesswork out of yourmeasurements. The large LCD display,intuitive user interface, and standard AAA batteries make Pocket Pro the easiest to use tester for your application.Pocket Pro’s superior probe andcalibration diagnostics for pH deliverconfidence in your results.

Page 30: Vwr - Electrochemistry-meters & Probes

301.800.932.5000

POCKET PRO+ TESTERS

The Pocket Pro+ series oIers all thebenefits of the Pocket Pro standardtesters, plus convenient backlight andreplaceable sensors. Have confidence inyour results with calibration options andpH diagnostics.

SpecificationsPocket Pro+

pHPocket Pro+

ORPPocket Pro+

Multi 1Pocket Pro+

Multi 2Parameter pH, Temp ORP Conductivity, TDS,

Salinity, TemppH, Conductivity, TDS,

Salinity, TempOperating TemperatureRange

0 to 50 °C 0 to 50 °C 0 to 50 °C 0 to 50 °C

Range 0.00 to 14.00 pH -999 to +999 mV Cond: Auto-ranging (0.0 to 199.9 µS/cm; 200 to 1999

µS/cm; 2.00 to 19.99 mS/cm)TDS: Auto-ranging

(0.0 to 99.9 ppm; 100 to 999 ppm; 1.00 to 10.00 ppt)Sal: Auto-ranging (0.00 to 10.00 ppt; 0.00 to 1.00%)

Temp: 0.0 to 50°C

pH: 0.00 to 14.00Cond: Auto-ranging (0.0 to 199.9 µS/cm; 200 to 1999

µS/cm; 2.00 to 19.99 mS/cm) TDS: Auto-ranging

(0.0 to 99.9 ppm; 100 to 999 ppm; 1.00 to 10.00 ppt)Sal: Auto-ranging (0.00 to 10.00 ppt; 0.00 to 1.00%)

Temp: 0.0 to 50°C Accuracy ± 0.02 pH 2 mV Cond: ± 1%

TDS: ± 1%Sal: ± 1%

Temp: ± 0.5°C

pH: ±0.02 pHCond: ±1%TDS: ±1%Sal: ±1%

Temp: ±0.5 °CResolution 0.01 pH 1 mV Cond: 0.1 µS/cm from

0.0 to 199.9 µS/cm; 1 µS/cmfrom 200 to 1999 µS/cm;

0.01 mS/cm from 2.00 to 19.99 mS/cmTDS: 0.1 ppm from

0.0 to 99.9 ppm; 1 ppm from 100 to 999 ppm; 0.01 ppt

from 0.00 to 10.00 pptSal: 0.01 ppt from 0.00 to

10.00 ppt; 0.01% from 0.00 to 1%Temp: 0.1°C

pH: 0.01 pHCond: 0.1 µS/cm from 0.0 to199.9 µS/cm; 1 µS/cm from

200 to 1999 µS/cm; 0.01 mS/cmfrom 2.00 to 19.99 mS/cmTDS: 0.1 ppm from 0.0 to

99.9 ppm; 1 ppm from 100 to 999 ppm;

0.01 ppt from 0.00 to 10.00 pptSal: 0.01 ppt from 0.00 to

10.00 ppt; 0.01% from 0.00 to 1%Temp: 0.1°C

TDS Factor — — adjustable; 0.71 default adjustable; 0.71 defaultBattery Requirements 4, AAA 4, AAA 4, AAA 4, AAAIP Rating IP67 IP67 IP67 IP67Backlight Yes Yes Yes Yes

Prod. No. 89508-374 89508-378 89508-382 89508-386Replacement Sensors 89508-376 is replacement

sensor for Pocket Pro+

pH Tester

89508-380 is replacementsensor for Pocket Pro+

ORP Tester

89508-384 is replacementsensor for Pocket Pro+

Multi 1 Tester

89508-388 is replacementsensor for Pocket Pro+

Multi 2 Tester

Page 31: Vwr - Electrochemistry-meters & Probes

31vwr.com

pH Calibration BuIersHach standard calibration buffers are available in convenient, unit-dose powder pillows or color-coded liquids. Powder pillowsassure freshness and eliminate the possibility of contamination.Recommended for automatic calibration. Simply open the pillow and add the contents to 50 mL of deionized or demineralized water.Both liquid and powder buffers assure accuracy (±0.02 pH units) and are NIST traceable.

pH Buffer PillowsBuffers with pH values of 4.01, 7.00, and 10.01 are color-coded foradded convenience. pH is ±0.02 at 25°C.

pH Buffer SolutionspH is ±0.02 at 25°C.

Singlet™ Solution PacksSinglet single-use standard solutions are ideal for on-site analysis,eliminating the need to prepare standardized buffer solutions for pHmeter calibration. You can have fresh pH buffer solutions withouthaving to purchase and carry deionized or demineralized water. Theconvenient foil-pouch packaging maintains freshness, and keeps thesolutions contaminant-free and ready to travel with you anywhere.

Description Quantity Cat. No.

pH 7.00 and pH 10.01 Buffer Solution

pk/10 of ea. 97021-730

pH 4.01 and pH 7.00 Buffer Solution pk/10 of ea. 97021-128

pH 4.01 Buffer Solution pk/20 97021-462

pH 7.00 Buffer Solution pk/20 97021-424

pH 10.01 Buffer Solution pk/20 97021-404

Cat. No. Description

20 L SIZE 3-PACK 97021-448 Includes:

97021-554 10.01 (blue) NIST

97021-558 7.00 (yellow) NIST

97021-556 4.01 (red) NIST

4 L SIZE 3-PACK97021-450 Includes:

97021-406 10.01 (blue) NIST

97021-440 7.00 (yellow) NIST

97021-510 4.01 (red) NIST

500 mL SIZE 3-PACK97021-452 Includes:

97021-552 10.01 (blue) NIST

97021-458 7.00 (yellow) NIST

97021-520 4.01 (red) NIST

Description Quantity Cat. No.Color-Coded4.01 (Red) 15 97021-766

50 97021-742250 97021-744

7.00 (Yellow) 15 97021-77050 97021-748250 97021-746

10.01 (Blue) 15 97021-76450 89231-016250 97021-808

4.01 (Red) 7.00 (Yellow) 10 of each 97021-806Colorless6.00 50 97021-8006.86 15 97021-7848.00 15 97021-7989.00 50 97021-792

pH Storage Solution Pillows 20 97021-756

Save when you purchase pH buIer 3-packs!

pH BUFFERS & STANDARD SOLUTIONS

Item Unit Cat. No.

pH 4.01 Color-Coded Red (NIST)500 mL 97021-5204 L 97021-51020 L 97021-556

pH 7.00 Color-Coded Yellow (NIST)500 mL 97021-4584 L 97021-44020 L 97021-558

pH 10.01 Color-Coded Blue (NIST)500 mL 97021-5524 L 97021-40620 L 97021-554

pH 4.01 Colorless (NIST)500 mL 97021-4384 L 97021-444

pH 7.00 Colorless (NIST)500 mL 97021-4264 L 97021-432

pH 10.01 Colorless (NIST)500 mL 97021-4084 L 97021-410

Page 32: Vwr - Electrochemistry-meters & Probes

©Hach Company, 2013. All rights reserved.

Specifications are subject to change without notice. Zeonor is a trademark of Nippon Zeon Co., Ltd. Corporation.

1113 5M Lit. No. 08077