vsec seminar march 26, 27 2008 virginia beach, va richmond, va david desutter, p.e
DESCRIPTION
VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E. Director of Engineering and Customer Service EFCO Corporation Mitch Snead The Snead Company. VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/1.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
VSEC SeminarMarch 26, 27 2008
Virginia Beach, VA
Richmond, VA
David DeSutter, P.E.
Director of Engineering and Customer Service
EFCO Corporation
Mitch Snead
The Snead Company
![Page 2: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/2.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
VSEC SeminarMarch 26, 27 2008
Virginia Beach, VA
Richmond, VA
Better Communication = Better Overall Structure
Pondering Point:
During a “design event,” the typical commercial “window” will fail due to either improper anchorage or under-designed surrounding
conditions.
![Page 3: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/3.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
VSEC SeminarMarch 26, 27 2008
•Curtain Wall vs. Storefront (General, Construction, Connection and Anchors)
•Curtain Wall Performance – Wind, Snow, Seismic, Thermal, Impact, Blast
•CW/SF Manufacturer’s Design Considerations (What We Need)
•CW/SF Manufacturer’s Design Considerations (What We Get)
•CW/SF Manufacturer’s Design Considerations (What We Assume)
•CW Analysis, Rules of Thumb
•Reference Information
![Page 4: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/4.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Available in three basic variations (“plane of glass”):
•outside set, •center set (a.k.a..flush glaze), •and inside set.
Storefront
OUTSIDE SET(S945)
CENTER SET(S403)
INSIDE SET(S433)
![Page 5: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/5.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Most Storefront is available in three (3) configurations (“glazing method”):
Outside glazed Inside glazed Vertical SSG glazed
Curtain Wall vs. Storefront - General
Storefront
![Page 6: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/6.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Most Storefront is available in two (2) types of connections (“installation method”):
Curtain Wall vs. Storefront - General
Storefront
![Page 7: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/7.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Most Storefront is available in limited widths and depths:
• 2” – 3” in width• 4” – 6 ½” in depth
Curtain Wall vs. Storefront - General
Storefront
![Page 8: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/8.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Curtain Wall
Primarily available in one basic variation (“plane of glass”):
![Page 9: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/9.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Curtain Wall
Primarily available in three (3) basic configurations (“glazing method”):
Outside glazed Inside glazed Structurally glazed
![Page 10: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/10.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Curtain Wall
Primarily available in two (3) basic connections (“installation method”):
Shear Block Screw Spline “Unitized”
![Page 11: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/11.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Curtain Wall
Options, Options, Options
![Page 12: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/12.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Water Performance
System Water Control
Curtain Wall “Zone Pressure Equalized”
Storefront Diverting Water through entire system
![Page 13: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/13.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Water Performance – Curtain Wall
![Page 14: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/14.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Water Performance – Storefront
![Page 15: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/15.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Water Performance – Storefront
![Page 16: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/16.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Curtain Wall Anchors – Head & Sill
Anchor Bolts Control!
Direct Load Path to MWFRS
RwlMovement Allowances
Unlimited (?)
![Page 17: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/17.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Anchor Bolts Control!
Curtain Wall Anchors – Head & Sill
![Page 18: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/18.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Curtain Wall Anchors – Intermediate/Slabs
Rwl
![Page 19: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/19.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Curtain Wall Anchors – Intermediate/Slabs
Rwl
“Wind Load” Anchor = Roller Support
“Dead Load” Anchor = Pin Support
![Page 20: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/20.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall vs. Storefront - General
Connections Control!
Storefront Anchors – Head, Sill & Jambs
Indirect Load Path to MWFRS
Rwl
Limited Movement
(1/8” max)
![Page 21: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/21.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
VSEC SeminarMarch 26, 27 2008
•Curtain Wall vs. Storefront (General, Construction, Connection and Anchors)
•Curtain Wall Performance – Wind, Snow, Seismic, Thermal, Impact, Blast
•CW/SF Manufacturer’s Design Considerations (What We Need)
•CW/SF Manufacturer’s Design Considerations (What We Get)
•CW/SF Manufacturer’s Design Considerations (What We Assume)
•CW Analysis, Rules of Thumb
•Reference Information
![Page 22: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/22.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Wind Considerations
•“Components and Cladding” provisions of ASCE 7 or Appropriate Building Code
•Corner Zones are Important! $
•Industry Standard Deflection Limits: L/175 (span <13’ – 6”), L/240 + ¼” (span >= 13’ – 6”)
•Accurate span information (dimensions), location of appropriate anchors! $$$$
•Aluminum Association ASD/LRFD
Goal: Transfer all wind forces to MWFRS
WL Reactions: 200 lbf to 3,500 lbf per anchor is typical
![Page 23: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/23.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Snow Considerations
•Flat Roof Snow Loads + Drift Surcharge on Bladed Sunshades is (?)
•Mullion Attachment Typical for Sunshades
Goal: Transfer all snow forces to curtain wall system, then to MWFRS
Effect of Snow on Reactions: Little effect to MWFRS
![Page 24: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/24.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Seismic Considerations
•Racking of CW – Engineer of Record Must Provide Calculated Interstory Drift!
•Controlled “Fallout” is the Standard (Fallout in ASCE 7)
Ps
![Page 25: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/25.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Seismic Considerations
•Shear Forces per ASCE 7
• Calculate Fp = .4ap(Sds)Wp/(Rp/Ip) (1+2(z/h))
• Fp= Seismic force acting at centroid of mullion, with load evenly distributed along length of mullion
– Fp acts the same as the wind load
– Varies for perimeter anchors
– Determine Deflection, Stress of frame member
– Can be problematic for intermediate
wind load anchors
![Page 26: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/26.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Seismic Considerations
•Racking of CW
•Shear Forces per ASCE 7
Goal: Transfer all seismic forces to MWFRS
Seismic Reactions: Usually 50% of WL (200 lbf to 3,500 lbf per anchor is typical), but in-plane along weak axis
![Page 27: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/27.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Thermal/Vertical Movement Considerations
•CW Mullions Buckle Easily
•Must Account for all Vertical Movement (Thermal + Building Movement) $$$$
•Must Maintain Integrity of Perimeter Sealant Joint and Satisify Architectural Aesthetics
•Sealant Joint RoT = ½ x Joint Width (Compression/Tension)
•“Standard” System (no “Bells & Whistles”) good for +/- ¼” to ½” +/-!!
![Page 28: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/28.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Thermal/Vertical Movement Considerations
Total VM = Thermal + LL + CS + Creep + DL
Thermal
Glass contact controls
![Page 29: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/29.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Thermal/Vertical Movement Considerations3 3 33333333
33
33
33
2 2
![Page 30: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/30.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Thermal/Vertical Movement Considerations
HL94
STV2STV2STV2
STK4 STK4
WN
E0
WN
E0
WE
EP
WN
E0
WV80STC0
5959
6345
S
ARCH./G.C. NOTE:COPING AT THIS LOCATION WILL SEE POSSIBLE3/4" OF MOVEMENT DUE TO THE THERMALEXPANSION OF VERTICAL MULLION. PLEASECONFIRM AS ACCEPTABLE.
Thermal + Slab Movement
![Page 31: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/31.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Thermal/Vertical Movement Considerations
Goal: Avoid all thermal forces to MWFRS
![Page 32: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/32.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWind, Snow, Seismic/Drift, Thermal/VM, Impact
and Blast
Impact Considerations
•Large Missile <30’ (ASTM E1996 and 1886)
•Small Missile >30’ (ASTM E1996/1886)
•Large Missile Dependant on Wind Speed!
•Identify Windborne Debris Region
1. Areas within one mile of the coastal mean high water line where the basic wind speed is equal to or greater than 110 mph and Hawaii
2. Areas where the basic wind speed is equal to or greater than 120 mph
![Page 33: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/33.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWind, Snow, Seismic/Drift, Thermal/VM, Impact
and Blast
![Page 34: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/34.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Part D. Missile GuidelinesLarge and Small Missile Impact per ASTM E 1996 - 06
EFCO UNIVERSITY 2008
ASTM E 1996 - 06
Missile Level Missile Impact Speed
A (10) 2 gram steel balls 130 f/s (39.62 m/s)
B 2 lb. 2 x 4 (1’-9”)lumber 50 f/s (15.25 m/s)
C 4.5 lb 2 x 4 (4’) lumber 40 f/s (12.19 m/s)
D 9 lb 2 x 4” (8’) lumber 50 f/s (15.25 m/s)
E 9 lb. 2 x 4 (8’) lumber 80 f/s (24.38 m/s)
![Page 35: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/35.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Part D. Missile GuidelinesLarge and Small Missile Impact per ASTM E 1996 - 06
EFCO UNIVERSITY 2008
ASTM E 1996 - 06
Missile Level Missile Impact Speed
A (10) 2 gram steel balls 130 f/s (39.62 m/s)
B 2 lb. 2 x 4 (1’-9”)lumber 50 f/s (15.25 m/s)
C 4.5 lb 2 x 4 (4’) lumber 40 f/s (12.19 m/s)
D 9 lb 2 x 4” (8’) lumber 50 f/s (15.25 m/s)
E 9 lb. 2 x 4 (8’) lumber 80 f/s (24.38 m/s)
Many projects will require level “C” or below
![Page 36: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/36.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Part D. Missile GuidelinesLarge and Small Missile Impact per ASTM E 1996 - 06
EFCO UNIVERSITY 2008
ASTM E 1996 - 06
Missile Level Missile Impact Speed
A (10) 2 gram steel balls 130 f/s (39.62 m/s)
B 2 lb. 2 x 4 (1’-9”)lumber 50 f/s (15.25 m/s)
C 4.5 lb 2 x 4 (4’) lumber 40 f/s (12.19 m/s)
D 9 lb 2 x 4” (8’) lumber 50 f/s (15.25 m/s)
E 9 lb. 2 x 4 (8’) lumber 80 f/s (24.38 m/s)
![Page 37: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/37.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Part D. Missile GuidelinesLarge and Small Missile Impact per ASTM E 1996 - 06
EFCO UNIVERSITY 2008
ASTM E 1996 - 06
Assembly Height Enhanced ProtectionBasic Protection
Wind Zone 1 C A D D
Wind Zone 2 C A D D
Wind Zone 3 D A E D
Wind Zone 4 D A E D
< 30 ft > 30 ft < 30 ft > 30 ft
110 < Wind < 120
Basic Wind Speed (MPH)
![Page 38: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/38.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Part E. ASTM vs. Florida Building Code
Large and Small Missile Impact per FBC/TAS 201 & 203
EFCO UNIVERSITY 2008
Pass/Fail per FBC and/or Dade/Broward Counties, Florida The specimen shall resist the impact and cyclic loading with no tear formed longer
than 5” and 1/16” in width through which air can pass.
All specimens have to be tested at the Florida Approved Lab.
TAS can NOT be tested at EFCO
If any specimen fails to meet the requirements, the set of specimens is rejected. A retest of all (3) specimens is permitted.
Cyclic Loading Identical to
ASTM E 1886
Small Missile Impact
Large Missile Impact
![Page 39: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/39.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Goal: Prevent Loss of Glass Bite
Reactions: Little to no effect to MWFRS due to impact
Impact Considerations
•Large Missile <30’ (ASTM E1996 and 1886)
•Small Missile >30’ (ASTM E1996/1886)
•Large Missile Dependant on Wind Speed!
•Identify Windborne Debris Region
![Page 40: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/40.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Blast Considerations
•Method 1: DoD UFC 04-010-01 = Prescriptive for “Low” or “Very Low” Level of Protection
•Method 2: Design for Specific Blast Load and Specific Level of Protection
![Page 41: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/41.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
![Page 42: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/42.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
![Page 43: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/43.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Performance
Wind, Snow, Seismic/Drift, Thermal/VM, Impact and Blast
Blast Considerations
Goal: Transfer Blast Loads to MWFRS
Reactions: Up to 20,000 lbf per anchor (extremely short duration)!
Wood, stud and masonry construction should be avoided for multi-lite or multi-span CW
![Page 44: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/44.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
VSEC SeminarMarch 26, 27 2008
•Curtain Wall vs. Storefront (General, Construction, Connection and Anchors)
•Curtain Wall Performance – Wind, Snow, Seismic, Thermal, Impact, Blast
•CW/SF Manufacturer’s Design Considerations (What We Need)
•CW/SF Manufacturer’s Design Considerations (What We Get)
•CW/SF Manufacturer’s Design Considerations (What We Assume)
•CW Analysis, Rules of Thumb
•Reference Information
![Page 45: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/45.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Need
Wind Considerations
1. Appropriate Code
2. Appropriate Exposure and Wind Speed
3. Accurate Span Information!
4. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions
![Page 46: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/46.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Need
V V
T
![Page 47: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/47.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Need
Snow Considerations
1. Appropriate Code
2. Appropriate Ground Snow Load and Drift Surcharge
![Page 48: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/48.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Need
Seismic/Drift Considerations
1. Appropriate Code
2. Must, Must, Must have calculated interstory drift!
3. Must have Sds (Design Spectral Response Acceleration, ASCE 7, Section 9.4.1.2) to calculate seismic shear.
![Page 49: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/49.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Need
Thermal/VM Considerations
1. Total Vertical Deflection per Floor
2. Is the Total Vertical Deflection “Up and Down” or Different?
3. (The CW Manufacturer Will Add in the Thermal Movements)
![Page 50: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/50.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Need
Impact Considerations
1. Appropriate Code (for DP)
2. Appropriate Wind Speed (Local Codes May Override Model BC)
3. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions
4. Identify Windborne Debris Regions
![Page 51: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/51.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Need
Blast Considerations
1. Charge and Standoff Distance or Blast Load and Impulse for “Blast Design” (DoD is prescriptive)
2. Appropriate Perimeter Condition (Structure) for Short Duration Blast Loads!
![Page 52: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/52.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Need
Blast Considerations
10K – 20K
![Page 53: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/53.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
VSEC SeminarMarch 26, 27 2008
•Curtain Wall vs. Storefront (General, Construction, Connection and Anchors)
•Curtain Wall Performance – Wind, Snow, Seismic, Thermal, Impact, Blast
•CW/SF Manufacturer’s Design Considerations (What We Need)
•CW/SF Manufacturer’s Design Considerations (What We Get)
•CW/SF Manufacturer’s Design Considerations (What We Assume)
•CW Analysis, Rules of Thumb
•Reference Information
![Page 54: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/54.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Get
Wind Considerations
1. Appropriate Code [No code or conflicting wind speeds – ie. 3 second gust wind speeds with fastest mile code]
2. Appropriate Exposure and Wind Speed [Conflicting wind speeds]
3. Accurate Span Information [“Like pulling teeth”]
4. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions [You be the judge - Plywood, 20 ga. Stud, face brick, masonry/concrete w/o edge distance are problematic]
Manufacturers Bid Documents:
1. Take-off from installer
2. Plans (Architecturals, limited Structurals) and Specs
![Page 55: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/55.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Get
Wind Considerations
3. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions [Is this lintel able to handle the wind loads?.]
200# - 3,500#
![Page 56: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/56.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Get
Wind Considerations
3. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions [Can this masonry handle these loads? If so, it is very difficult for the CW anchor to hit the center of the cell.]
200# - 3,500#
![Page 57: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/57.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Get
Wind Considerations
3. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions [No doubt the concrete can handle the wind loads, but maintaining edge distance is impossible w/o customization.]
200# - 3,500#
![Page 58: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/58.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Get
Snow Considerations
1. Appropriate Code [Code is identified 50% of time.]
2. Appropriate Ground Snow Load [Ground snow load is specified in some cases, drift surcharge is rarely, if ever specified…]
![Page 59: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/59.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Get
Seismic/Drift Considerations
1. Appropriate Code [Typical spec: “Curtain wall system must be designed to resist appropriate seismic forces and displacements…..”]
2. Must, Must, Must have calculated interstory drift. [See above.]
3. Must have Design Spectral Response Acceleration (Sds) variable to calculate seismic shear (ASCE 7, Section 9.4.1.2) [This is rarely, if ever provided in specifications]
![Page 60: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/60.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Get
Thermal/VM Considerations
1. Total Vertical Deflection per Floor (not the Allowable by Code!) [Sometimes we get the LL, column shortening and creep as a maximum for all floors, all spans. Most of the time, spec reads: “…curtain wall system must be designed to accommodate deflections including, but not limited to live load, dead load, column shortening, creep and thermal expansion and contraction of the curtain wall system assuming a temperature differential of 180 deg F…”]
2. Is the Total Vertical Deflection “Up and Down” or Different? [Rarely get different values for “up” and “down,” see above]
3. (The CW Manufacturer Will Add in the Thermal Movements)
![Page 61: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/61.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Get
Impact Considerations
1. Appropriate Code (for DP) [No code or conflicting wind speeds – ie. 3 second gust wind speeds with fastest mile code]
2. Appropriate Wind Speed (Local Codes May Override Model BC) [Conflicting wind speeds]
3. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions [You be the judge…]
![Page 62: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/62.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Get
Blast Considerations
1. Charge and Standoff Distance or Blast Load and Impulse for “Blast Design” (DoD is prescriptive) [Rarely if ever specified…]
2. Appropriate Perimeter Condition (Structure) for Short Duration Blast Loads! [Our opinion is the perimeter structure is generally ignored for windows and CW for blast projects …]
10,000# +
![Page 63: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/63.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
![Page 64: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/64.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
VSEC SeminarMarch 26, 27 2008
•Curtain Wall vs. Storefront (General, Construction, Connection and Anchors)
•Curtain Wall Performance – Wind, Snow, Seismic, Thermal, Impact, Blast
•CW/SF Manufacturer’s Design Considerations (What We Need)
•CW/SF Manufacturer’s Design Considerations (What We Get)
•CW/SF Manufacturer’s Design Considerations (What We Assume)
•CW Analysis, Rules of Thumb
•Reference Information
![Page 65: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/65.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Assume
Wind Considerations
1. Appropriate Code [No code or conflicting wind speeds – ie. 3 second gust wind speeds with fastest mile code] [Assume latest ASCE 7.]
2. Appropriate Exposure and Wind Speed [Conflicting wind speeds] [Assume an Exposure Cat. (usually “C”) and wind speed based on map.]
3. Accurate Span Information [“Like pulling teeth”] [“Quote and qualify” then hope for the best and plan for the worst]
4. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions [You be the judge - Plywood, 20 ga. Stud, face brick, masonry/concrete w/o edge distance are problematic] [Assume that condition will support loads, assume architect passes info to engineer of record.]
![Page 66: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/66.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Assume
Wind Considerations
3. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions [Plywood, 20 ga. Stud, face brick, masonry/concrete w/o edge distance and lintels.] [Assume that condition will support loads, address water concern, redesign anchor as necessary, assume architect passes info to engineer of record.]
200# - 3,500#
![Page 67: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/67.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Assume
Wind Considerations
3. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions [Plywood, 20 ga. Stud, face brick, masonry/concrete w/o edge distance and lintels.] [Assume that condition will support loads, redesign anchor as necessary, assume architect passes info to engineer of record.]
200# - 3,500#
![Page 68: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/68.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Assume
Wind Considerations
3. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions [Plywood, 20 ga. Stud, face brick, masonry/concrete w/o edge distance and lintels.] [Assume that condition will support loads, redesign anchor as necessary, assume architect passes info to engineer of record.]
200# - 3,500#
![Page 69: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/69.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Assume
Snow Considerations
1. Appropriate Code [Code is identified 50% of time.] [Assume ASCE 7]
2. Appropriate Ground Snow Load [Ground snow load is specified in some cases, drift surcharge is rarely, if ever specified…] [Assume ground snow loads in ASCE 7, use best judgment on drift surcharge.]
![Page 70: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/70.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Assume
Seismic/Drift Considerations
1. Appropriate Code [Typical spec: “Curtain wall system must be designed to resist appropriate seismic forces and displacements…..”] [Assume ASCE 7, but……..]
2. Must, Must, Must have calculated interstory drift. [See above.] [Assume that our “standard” performance for fallout is less than the calculated interstory drift, communicate to architect, assume that this information is passed to Engineer of Record. This information is rarely provided.]
3. Must have Design Spectral Response Acceleration (Sds) variable to calculate seismic shear (ASCE 7, Section 9.4.1.2) [This is rarely, if ever provided in specifications] [Make a call to customer/architect. Thus far, this information is almost always provided.]
![Page 71: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/71.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Assume
Thermal/VM Considerations
1. Total Vertical Deflection per Floor (not the Allowable by Code!) [Sometimes we get the LL, column shortening and creep as a maximum for all floors, all spans. Most of the time, spec reads: “…curtain wall system must be designed to accommodate deflections including, but not limited to live load, dead load, column shortening, creep and thermal expansion and contraction of the curtain wall system assuming a temperature differential of 180 deg F…”] [Assume that our standard system as quoted will meet the requirement - bad assumption. Hard splice everywhere possible to minimize moving joints. Use realistic F.]
2. Is the Total Vertical Deflection “Up and Down” or Different? [Rarely get different values for “up” and “down,” see above] [Assume same “up” and “down” deflections.]
3. (The CW Manufacturer Will Add in the Thermal Movements) […using “realistic” F…]
![Page 72: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/72.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Assume
Impact Considerations
1. Appropriate Code (for DP) [No code or conflicting wind speeds – ie. 3 second gust wind speeds with fastest mile code] [Use ASCE 7.]
2. Appropriate Wind Speed (Local Codes May Override Model BC) [Conflicting wind speeds] [Use ASCE 7 wind speed map.]
3. Appropriate Perimeter Condition (Structure) for “Higher” DP Regions [You be the judge…] [Assume that condition will support loads, assume architect passes info to engineer of record.]
![Page 73: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/73.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall PerformanceWhat We (Manufacturers) Assume
Blast Considerations
1. Charge and Standoff Distance or Blast Load and Impulse for “Blast Design” (DoD is prescriptive) [Rarely if ever specified…]
2. Appropriate Perimeter Condition (Structure) for Short Duration Blast Loads! [Our opinion is the perimeter structure is ignored…] [Assume that condition will support loads, design anchor and connection accordingly, assume architect passes info to engineer of record. Bad assumption in the case below…]
10K – 20K
![Page 74: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/74.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
VSEC SeminarMarch 26, 27 2008
•Curtain Wall vs. Storefront (General, Construction, Connection and Anchors)
•Curtain Wall Performance – Wind, Snow, Seismic, Thermal, Impact, Blast
•CW/SF Manufacturer’s Design Considerations (What We Need)
•CW/SF Manufacturer’s Design Considerations (What We Get)
•CW/SF Manufacturer’s Design Considerations (What We Assume)
•CW Analysis, Rules of Thumb
•Reference Information
![Page 75: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/75.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Analysis, Rules of Thumb
Basic Assumptions for the Engineer of Record When Considering CW:
1. DL of CW = 10 lb/sf
2. Assume 1/8” per 10’ of span for thermal movement
3. CW engineers assume combination of pin and roller connections
4. Most “Box Stock” CW system can only handle ¼” to ½” of total vertical movement (w/o customization).
5. Typical CW is spliced (hinged) at every 20’
6. CW/SF is very resistant to (seismic) drift, but very difficult to calculate
7. Post tension conc. slabs with minimal cover cause severe pain to CW engineers (typ. anchor bolt embedment > 2 ½”)
![Page 76: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/76.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Curtain Wall Analysis, Rules of Thumb
![Page 77: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/77.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
![Page 78: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/78.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
![Page 79: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/79.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
![Page 80: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/80.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
VSEC SeminarMarch 26, 27 2008
•Curtain Wall vs. Storefront (General, Construction, Connection and Anchors)
•Curtain Wall Performance – Wind, Snow, Seismic, Thermal, Impact, Blast
•CW/SF Manufacturer’s Design Considerations (What We Need)
•CW/SF Manufacturer’s Design Considerations (What We Get)
•CW/SF Manufacturer’s Design Considerations (What We Assume)
•CW Analysis, Rules of Thumb
•Reference Information
![Page 81: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/81.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
Reference Information
www.efcocorp.com!
![Page 82: VSEC Seminar March 26, 27 2008 Virginia Beach, VA Richmond, VA David DeSutter, P.E](https://reader036.vdocuments.us/reader036/viewer/2022081515/568145bd550346895db2c6ba/html5/thumbnails/82.jpg)
Manufacturer
Of
Architectural
And
Commercial
Grade
Windows,
Curtain Walls,
Entrances,
And
Storefronts
EFCO UNIVERSITY 2008
What’s on Your Mind?