vrf v5x series 50hz - airwave v5x series 50hz. there are three production bases: ... midea cac is a...
TRANSCRIPT
iOS Version Android Version
Midea CAC After-service Application
iOS Version
Midea CAC News Application
1602-1V1509
Commercial Air Conditioner DivisionMidea GroupAdd.: West Region of Midea Commercial Air Conditioner Department, Industry Avenue,
Beijiao, Shunde, Foshan, Guangdong, P. R. China
Postal code: 528311
Tel: +86-757-26338346 Fax: +86-757-22390205
cac.midea.com global.midea.com
Note: The data in this book may be changed without notice for further improvement
on quality and performance.
Commercial Air Conditioners 2016
VRF V5X Series50Hz
There are three production bases: Shunde, Chongqing and Hefei.
MCAC Shunde: 38 product lines focusing on VRF, Split Products, Heat Pump Water Heaters, and AHU/FCU.
MCAC Chongqing: 14 product lines focusing on Water Cooled Centrifugal/Screw/Scroll Chillers, Air Cooled
Screw/Scroll Chillers, and AHU/FCU.
MCAC Hefei: 11 product lines focusing on VRF, Chillers, and Heat Pump Water Heaters.
Midea CACMidea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider
of heating, ventilation and air conditioning solutions. Midea CAC has continued with the tradition of
innovation upon which it was founded, and emerged as a global leader in the HVAC industry. A strong
drive for advancement has created a groundbreaking R&D department that has placed Midea CAC at the
forefront of a competitive field. Through these independent efforts and joint cooperation with other
global enterprises, Midea has supplied thousands of innovative solutions to customers worldwide.
Midea Company Introduction
Midea CAC Introduction
2014-2015
2014
2011-2014
2011-2012
2009
2008
2000-2001
1999
Win FIFA World Cup Stadiums project in Brazil Beira Rio, Olympic Games Stadiums project in Brazil
Rio de Janeiro and Africa games Stadiums project in Congo Brazzaville successively
Launched the All DC Inverter V5X globally, outstanding product performance helps Midea leading
VRF market
Launched the DC Inverter V4 Plus Series successively, complete product lines help Midea
successfully enter the mainstream VRF market
J.V. with Carrier LA and Carrier India successively
Launched the DC Inverter V4 globally
Developed DC inverter technology with Toshiba
Cooperated with Toshiba and Copeland, enter VRF field
Entered the CAC field
03 04
Technology Inspires Possibilities
HP 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88
OUTDOOR UNIT LINEUP
Single unit
Multi combination
05 06
Technology Inspires Possibilities
OUTDOOR UNITSVRF V5 X SYSTEM
High E�ciency
Wide Application Range
High Reliability
Enhanced Comfort
Easy Installation and Service
V5X Introduction
07 08
Technology Inspires Possibilities
Multi Solenoid Valves Control
Newly Designed Fan A new blade with sharp edges and a slight curve increases the airflow rate and lowers vibration and airflow resistance.
Multi solenoid valves control technology in one system. All the solenoid valves equipped in the unit ensure precise
temperature control, stable and efficient running conditions and improved comfort.
Double EXVs ControlDouble EXVs in one system, each EXV part achieves
480 Pulse rate to precisely adjust refrigerant flow.
High E�ciency Heat Exchanger
Newly designed window type fins enlarge the heat exchange area and
decrease air resistance, enhance heat exchange performance and save more
energy.
Hydrophilic fins and internally threaded copper pipes optimize heat
exchange efficiency.
δ design increases the hot liquid rate in the condenser and improves the
heat-exchange efficiency.
The DC inverter compressor adopts innovative design
and numerous high performance key parts which can
reduce power consumption by 25%.
All DC Inverter Compressors
All DC Fan MotorsThe system controls the speed of the fan motor according to the system pressure and system load achieving the minimum
power consumption.
High EER and COP Values
V5 X Series achieves the industry's top class energy efficiency in cooling and heating by utilizing all
DC inverter compressors, all DC fan motors, and high efficiency heat exchanger.
The cooling EER is up to 4.7 and the heating COP is up to 5.6 in the 8HP category.
EER
8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP
4.70
4.504.30 4.30
4.10 3.90 3.86 3.74
COP
5.605.30
4.904.80
4.60
4.254.12 4.03
8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP
New structure enhancesmid-frequency performance
Advanced permanentmagnet DC motor improves low-
frequency band performance
More compact, weightreduced by 50%
Specially designedscroll profile for R410A
Low
High
15 steps vector control
Gas
Gas
Gas
Liquid
Liquid
Liquid
Gas LiquidGas-Liquid
Original design
New design
43°C
75°C 75°C
37°C
δ design
75°C
37°C
High Efficiency
09 10
Technology Inspires Possibilities
Wide Capacity Range
V5X Series has extensive capacity ranging
from 8HP to 88HP, meets al l customer
requirement concerning small to large
buildings.
V5X Series operates stably under extreme conditions,
ranging from minus 20°C to 48°C.
Long Piping Length
Leve
l diff
eren
ce b
etw
een
IDU
~ID
U 3
0m
90mLo
nges
t act
ual p
ipin
g le
ngth
175
m
Leve
l diff
eren
ce b
etw
een
IDU
~O
DU
110
m
*The longest piping length is 40m standard. It can be extended to 90m. When the length is over 40m, please contact your local Midea dealer for more information and restrictions.
Total piping length 1000m
175(200)m
90*m
70(110)m
30m
Longest length actual (Equivalent)
Longest length after first branch
Level difference between indoor and outdoor units - ODU up (down)
Level difference between indoor units
Precise Oil Control Technology
Cycle Duty Operation
Backup OperationIn a multiple system, if one module is failed, other
modules can be backup instead of the failed one for
continuing operation.
The cyclical start-up sequence of outdoor units and DC inverter compressors equalized compressor duty and extends operating
life.
1st stage
2nd stage
3rd stage
4th stage
5th stage
5 stages oil control technology ensures all outdoor unit and compressor oil is always kept at a safe level, completely solving any
compressor oil shortage problems.
1st stage: Compressor internal oil separation.
2nd stage: High efficiency centrifugal oil separator (separation efficiency up to 99%) ensures oil separated from the discharge
gas is returned to the compressors.
3rd stage: Oil balance pipes between compressors ensure even oil distribution to keep compressors running normally.
4th stage: Oil balance pipes among modules ensure even oil distribution among modules.
5th stage: Auto oil return program by monitoring the running time and system status ensures reliable oil return.
Wide Operation RangeWide Range of Indoor Units
Midea provides 12 types and more than 100 models of VRF indoor
units maximum meeting varied customer requirements. It widely
applied in market, hospital, office building, hotel, airport, etc..
48°C
-5°C
24°C
-20°C
COOLING MODE
HEATING MODE-20°C
-10°C
0°C
10°C
20°C
30°C
40°C
50°C
1 2 3 4 1 2 34 3 4 1 2 2 3 4 1
Wide Application Range High Reliability
11 12
Technology Inspires Possibilities
Night Silent Mode feature which is easily set on the PCB board allows the unit to be set to various time options during Non-peak
and Peak operation time minimizing the units noise output.
Night Silent Operation Mode
Intelligent defrosting program will judge the
defrosting time according to the system real
requirement, reduce heating loss caused by
unnecessary defrosting and create more comfort.
Defrosting time can be shortened to 4 min. due to
the specialized defrosting valve.
Hea
ting
capa
city
Usual defrosting
∆t
Time
t min
Intelligent defrosting
Intelligent Defrosting Technology
The DC Inverter Compressor system reaches full load rapidly
providing less temperature fluctuation and an improved living
environment.
Rapid Warm Up And Cool Down Function
2
Fluctuation of room temperature
Cooling operation
1
Temp
Inverter Non-Inverter
Time
Simple Communication Wiring
Rotatable Electric Control Box
Centralized controller (CCM03 or CCM30) can be connected from indoor side or outdoor side (XYE terminals) at will.
With one set of wires, we can achieve the network communication and system communication, making installation at site more
convenient.
The newly designed rotating control box can rotate on a maximum of 150 degree. It is convenient for the inspection and
maintenance of the pipeline system and greatly reduces the dismount time of the electric control box.
P Q EX Y E X Y E P Q E P Q E P Q E P Q E
Outside Inside
Sound drop 15dB(A)
Quiet
Easy MaintainenceInspection window for checking the systems status.
Compressor is located near the door, which simplifies
checks and enables valve or compressor parts to be
replaced easily.
Self-diagnosis function helps service engineers
locate faults quickly and easily.
Auto Addressing
Outdoor unit can distribute addresses for
indoor units automatically.
Wireless and wired controllers can query and
modify each indoor unit's address.1
2
3
4
5
6
7
8
910
Enhanced Comfort Easy Installation and Service
Max. 150o
13 14
Technology Inspires Possibilities
Speci�cations Speci�cations
Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.Piping length: Interconnecting piping length is 7.5m, level difference is zero.Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.Piping length: Interconnecting piping length is 7.5m, level difference is zero.Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
380-415/3/50
50~130% of outdoor unit capacity
DC inverter
DC motor
20 (default)60 (customized)
R410A
Φ8
Cooling: -5-48; Heating: -20-24
HPModelPower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipe connections
Air flow rateSound pressure levelSound power levelNet dimension (W×H×D)Packing size (W×H×D)Net weight Gross weightOperating temperature range
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityMax Static Pressure
TypeFactory chargingLiquid pipeGas pipeOil balance pipe
V/Ph/HzkWkW
kWkW
PaPa
kgmmmmmmm3/hdB(A)dB(A)mmmmkgkg°C
8MV5-X252W/V2GN1
25.2 5.36 4.70 8.2527.0 4.82 5.60
13
1
1
9Φ12.7Φ25.4
120005870
219234
10MV5-X280W/V2GN1
28.0 6.22 4.50 7.9031.5 5.94 5.30
16
1
1
9Φ12.7Φ25.4
120005971
990×1635×7901055×1805×855
219234
12MV5-X335W/V2GN1
33.5 7.79 4.30 7.5437.5 7.65 4.90
20
1
1
11Φ15.9Φ28.6
120006072
237252
14MV5-X400W/V2GN1
40.0 9.30 4.30 7.5445.0 9.38 4.80
23
2
2
13Φ15.9Φ31.8
140006274
1340×1635×7901405×1805×855
297315
380-415/3/50
50~130% of outdoor unit capacity
DC inverter2
DC motor2
20 (default)60 (customized)
R410A
Φ8
1340×1635×7901405×1805×855
Cooling: -5-48; Heating: -20-24
HPModelPower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipe connections
Air flow rateSound pressure levelSound power levelNet dimension (W×H×D)Packing size (W×H×D)Net weight Gross weightOperating temperature range
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityMax Static Pressure
TypeFactory chargingLiquid pipeGas pipeOil balance pipe
V/Ph/HzkWkW
kWkW
PaPa
kgmmmmmmm3/hdB(A)dB(A)mmmmkgkg°C
16MV5-X450W/V2GN1
45.0 10.98 4.10 7.2050.0
10.87 4.60
26
13Φ15.9Φ31.8
14000 6274
297315
18MV5-X500W/V2GN1
50.0 12.82 3.90 7.3656.0
13.18 4.25
29
13Φ19.1Φ31.8
16000 6375
305323
20MV5-X560W/V2GN1
56.0 14.51 3.86 7.2863.0
15.29 4.12
33
16Φ19.1Φ31.8
16000 6375
340358
22MV5-X615W/V2GN1
61.5 16.44 3.74 7.0469.0
17.12 4.03
36
16Φ19.1Φ31.8
16000 6375
340358
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipe connections
Air flow rateSound pressure levelSound power levelNet dimension (W×H×D)Packing size (W×H×D)Net weight Gross weightOperating temperature range
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingLiquid pipeGas pipeOil balance pipe
V/Ph/HzkWkW
kWkW
kgmmmmmmm3/hdB(A)dB(A)mmmmkgkg°C
380-415/3/50
50~130% of outdoor unit capacity
DC inverter
DC motor
R410A
Φ8
Cooling: -5-48; Heating: -20-24
24MV5-X670W/V2GN1
12HP×2
67.0 15.58 4.30 7.5475.0
15.31 4.90
39
2
2
11×2Φ15.9Φ28.6
24000 6476
(990×1635×790)×2(1055×1805×855)×2
237×2252×2
26MV5-X730W/V2GN1
10HP+16HP
73.0 17.20 4.24 7.4781.5
16.81 4.85
43
3
3
9+13Φ19.1Φ31.8
26000 6577
219+297234+315
28MV5-X780W/V2GN1
10HP+18HP
78.0 19.04 4.10 7.5087.5
19.12 4.58
46
3
3
9+13Φ19.1Φ31.8
28000 6577
219+305234+323
30MV5-X840W/V2GN1
10HP+20HP
84.0 20.73 4.05 7.5294.5
21.23 4.45
50
3
3
9+16Φ19.1Φ31.8
28000 6577
990×1635×790+1340×1635×7901055×1805×855+1405×1805×855
219+340234+358
32MV5-X895W/V2GN1
10HP+22HP
89.5 22.67 3.95 7.42
100.523.06 4.36
53
3
3
9+16Φ19.1Φ31.8
280006577
219+340234+358
34MV5-X950W/V2GN1
12HP+22HP
95.0 24.23 3.92 7.38
106.524.77 4.30
56
3
3
11+16Φ19.1Φ31.8
280006577
237+340252+358
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipe connections
Air flow rateSound pressure levelSound power levelNet dimension (W×H×D)Packing size (W×H×D)Net weight Gross weightOperating temperature range
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingLiquid pipeGas pipeOil balance pipe
V/Ph/HzkWkW
kWkW
kgmmmmmmm3/hdB(A)dB(A)mmmmkgkg°C
380-415/3/50
50~130% of outdoor unit capacity
DC inverter4
DC motor4
R410A
Φ19.1Φ38.1
Φ8
6678
Cooling: -5-48; Heating: -20-24
36MV5-X1000W/V2GN1
18HP×2
100.0 25.64 3.90 7.36
112.0 26.35 4.25
59
13×2
32000
305×2323×2
38MV5-X1065W/V2GN1
16HP+22HP
106.5 27.42 3.88 7.32
119.0 27.99 4.25
63
13+16
30000
297+340315+358
40MV5-X1115W/V2GN1
18HP+22HP
111.5 29.26 3.81 7.10
125.0 30.30 4.13
64
13+16
32000
(1340×1635×790)×2(1405×1805×855)×2
305+340323+358
42MV5-X1175W/V2GN1
20HP+22HP
117.5 30.95 3.80 7.08
132.0 32.41 4.07
64
16×2
32000
340×2358×2
44MV5-X1230W/V2GN1
22HP×2
123.0 32.89 3.74 7.04
138.0 34.24 4.03
64
16×2
32000
340×2358×2
46MV5-X1285W/V2GN1
12HP×2+22HP
128.532.03 4.01 7.49
144.0 32.43 4.44
64
11×2+16
40000
(990×1635×790)×2+1340×1635×790
(1055×1805×855)×2+1405×1805×855
237×2+340252×2+358
Speci�cations Speci�cations
15 16
Technology Inspires Possibilities
Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.Piping length: Interconnecting piping length is 7.5m, level difference is zero.Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.Piping length: Interconnecting piping length is 7.5m, level difference is zero.Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipe connections
Air flow rateSound pressure levelSound power levelNet dimension (W×H×D)Packing size (W×H×D)Net weight Gross weightOperating temperature range
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingLiquid pipeGas pipeOil balance pipe
V/Ph/HzkWkW
kWkW
kgmmmmmmm3/hdB(A)dB(A)mmmmkgkg°C
48MV5-X1345W/V2GN1
10HP+16HP+22HP
134.5 33.64 4.00 7.48
150.5 33.93 4.44
9+13+16Φ19.1Φ38.1
42000
219+297+340234+315+358
50MV5-X1395W/V2GN1
10HP+18HP+22HP
139.5 35.49 3.93 7.40
156.5 36.24 4.32
9+13+16Φ19.1Φ38.1
44000
219+305+340234+323+358
52MV5-X1455W/V2GN1
10HP+20HP+22HP380-415/3/50
145.5 37.17 3.91 7.37
163.5 38.36 4.26
50~130% of outdoor unit capacity64
DC inverter5
DC motor5
R410A9+16×2Φ22.2Φ41.3
Φ844000
6779
990×1635×790+(1340×1635×790)×21055×1805×855+(1405×1805×855)×2
219+340×2234+358×2
Cooling: -5-48; Heating: -20-24
54MV5-X1510W/V2GN1
10HP+22HP×2
151.0 39.11 3.86 7.28
169.5 40.19 4.22
9+16×2Φ22.2Φ41.3
44000
219+340×2234+358×2
56MV5-X1565W/V2GN1
12HP+22HP×2
156.540.68 3.85 7.18
175.541.90 4.19
11+16×2Φ22.2Φ41.3
44000
237+340×2252+358×2
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipe connections
Air flow rateSound pressure levelSound power levelNet dimension (W×H×D)Packing size (W×H×D)Net weight Gross weightOperating temperature range
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingLiquid pipeGas pipeOil balance pipe
V/Ph/HzkWkW
kWkW
kgmmmmmmm3/hdB(A)dB(A)mmmmkgkg°C
70MV5-X1960W/V2GN110HP+16HP+22HP×2
196.0 50.09 3.91 7.37
219.5 51.06 4.30
9+13+16×2
58000
219+297+340×2234+315+358×2
72MV5-X2010W/V2GN110HP+18HP+22HP×2
201.0 51.93 3.87 7.30
225.5 53.36 4.23
9+13+16×2
60000
219+305+340×2234+323+358×2
74MV5-X2070W/V2GN110HP+20HP+22HP×2
380-415/3/50207.0 53.62 3.86 7.28
232.5 55.48 4.19
50~130% of outdoor unit capacity64
DC inverter7
DC motor7
R410A9+16×3Φ25.4Φ44.5
Φ860000
6981
(990×1635×790)+(1340×1635×790)×3(1055×1805×855)+(1405×1805×855)×3
219+340×3234+358×3
Cooling: -5-48; Heating: -20-24
76MV5-X2125W/V2GN1
10HP+22HP×3
212.5 55.55 3.83 7.12
238.5 57.31 4.16
9+16×3
60000
219+340×3234+358×3
78MV5-X2180W/V2GN1
12HP+22HP×3
218.0 57.12 3.82 7.11
244.559.02 4.14
11+16×3
60000
237+340×3252+358×3
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipe connections
Air flow rateSound pressure levelSound power levelNet dimension (W×H×D)Packing size (W×H×D)Net weight Gross weightOperating temperature range
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingLiquid pipeGas pipeOil balance pipe
V/Ph/HzkWkW
kWkW
kgmmmmmmm3/hdB(A)dB(A)mmmmkgkg°C
80MV5-X2230W/V2GN1
18HP×2+22HP×2
223.0 58.53 3.81 7.10
250.0 60.60 4.13
13×2+16×2
64000
305×2+340×2323×2+358×2
82MV5-X2295W/V2GN1
16HP+22HP×3
229.5 60.31 3.81 7.10
257.0 62.23 4.13
13+16×3
62000
297+340×3315+358×3
84MV5-X2345W/V2GN1
18HP+22HP×3380-415/3/50
234.5 62.15 3.77 7.05
263.0 64.54 4.07
50~130% of outdoor unit capacity64
DC inverter8
DC motor8
R410A13+16×3
Φ25.4Φ44.5
Φ864000
7082
(1340×1635×790)×4(1405×1805×855)×4
305+340×3323+358×3
Cooling: -5-48; Heating: -20-24
86MV5-X2405W/V2GN1
20HP+22HP×3
240.5 63.84 3.77 7.05
270.0 66.66 4.05
16×4
64000
340×4358×4
88MV5-X2460W/V2GN1
22HP×4
246.0 65.78 3.74 7.04
276.0 68.49 4.03
16×4
64000
340×4358×4
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipe connections
Air flow rateSound pressure levelSound power levelNet dimension (W×H×D)Packing size (W×H×D)Net weight Gross weightOperating temperature range
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingLiquid pipeGas pipeOil balance pipe
V/Ph/HzkWkW
kWkW
kgmmmmmmm3/hdB(A)dB(A)mmmmkgkg°C
380-415/3/50
50~130% of outdoor unit capacity64
DC inverter6
DC motor6
R410A
Φ8
6880
Cooling: -5-48; Heating: -20-24
58MV5-X1615W/V2GN1
18HP×2+22HP
161.5 42.08 3.84 7.13
181.0 43.47 4.16
13×2+16Φ22.2Φ41.3
48000
305×2+340323×2+358
60MV5-X1680W/V2GN1
16HP+22HP×2
168.0 43.86 3.83 7.12
188.0 45.11 4.17
13+16×2Φ22.2Φ41.3
46000
297+340×2315+358×2
62MV5-X1730W/V2GN1
18HP+22HP×2
173.0 45.71 3.78 7.06
194.0 47.42 4.09
13+16×2Φ22.2Φ41.3
48000
(1340×1635×790)×3(1405×1805×855)×3
305+340×2323+358×2
64MV5-X1790W/V2GN1
20HP+22HP×2
179.0 47.40 3.78 7.06
201.0 49.53 4.06
16×3Φ22.2Φ41.3
48000
340×3358×3
66MV5-X1845W/V2GN1
22HP×3
184.549.33 3.74 7.04
207.0 51.36 4.03
16×3Φ22.2Φ41.3
48000
340×3358×3
68MV5-X1900W/V2GN1
12HP×2+22HP×2
190.0 48.47 3.92 7.38
213.0 46.13 4.62
11×2+16×2Φ25.4Φ44.5
56000
(990×1635×790)×2+(1340×1635×790)×2
(1055×1805×855)×2+(1405×1805×855)×2
237×2+340×2252×2+358×2