• Capable of testing A and B type regulators• Test 12 Volt type regulators at 0.5A and 3A• Test 24 Volt regulators at 1A field current• Universal power supply, 100 to 240 volts,
47-64hz• Voltmeter display• Short-circuit protected• Dual stator test capability• “C” function test• Choke test• Over voltage lamp test
• LIN/BSS test capability at 13,14 and 15 Volts
• Ford PCM test capability 13, 14, 15 Volts• Test PD type regulators• Robust and stackable metal box • Universal tester adapter plus VRC2010-002
(included)• Additional tester adapter plugs available for
testing Bosch, Denso, Ford, Mando, Marelli, Mitsubishi, Valeo type voltage regulators
VRC2010-003
VRC2010-001VRC2010-005
VRC2010-002
VRC2010-004VRC2010-006
Voltage Regulator Tester & Harnesses
VRC2010
![Page 3: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/3.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsCHRYSLER
VOLTFLD SET POINTPART NO.
C8312
C8313
C8315
A
A
A
12
12
12
14.3
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
N/A
11/21/2014Revision: Date :C-01Product Group1Page
![Page 4: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/4.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsCHRYSLER
VOLTFLD SET POINTPART NO.
C8010
C8012
B
B
12
12
14.3
14.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
N/A
11/21/2014Revision: Date :C-02Product Group 3/12/19992Page
![Page 5: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/5.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsC.A.V.
VOLTFLD SET POINTPART NO.
CE520
CE520
CE520
A
A
A
24
24
24
HI 28.8
MID 27.8
LO 26.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :CE-01Product Group 3/10/19993Page
![Page 6: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/6.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsC.A.V.
VOLTFLD SET POINTPART NO.
CE301 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :CE-03Product Group 3/8/19994Page
![Page 7: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/7.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDAEWOO
VOLTFLD SET POINTPART NO.
D403 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
D403 Special Note: POWER ON field lamp may blink or illuminate steady-on to indicate a functional circuit.
D403 Special Note: POWER ON field lamp may blink or illuminate steady-on to indicate a functional circuit.
11/21/2014Revision: Date :DA-01Product Group 10/22/19075Page
![Page 8: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/8.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D32S
D10SE6
D105
D105HD
A
A
A
A
32
6
12
12
37.5
7.7
14.8
14.8
VOLTFLD SET POINTPART NO.
D10SE12
D101
D101HD
A
A
A
12
12
12
14.8
14.8
14.8
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-02Product Group6Page
![Page 9: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/9.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D17SE
D102HD
D30S
D27
A
A
A
A
12
12
24
12
14.2
13.7
27.5
13.7
VOLTFLD SET POINTPART NO.
D27S A 12 14.0
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-03Product Group7Page
![Page 10: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/10.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D9212
D9212S
D9212C
D6374
B
B
B
B
12
12
12
12
14.2
14.2
14.2
14.6
VOLTFLD SET POINTPART NO.
D6378
D6377
D518
B
B
B
12
12
24
14.6
14.6
27.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
On all above parts numbers except D6377, disconnect red test lead from the terminal marked with "S" Indicatorlight should turn on and the meter will indicate set point voltage.
11/21/2014Revision: Date :D-06Product Group 5/1/19978Page
![Page 11: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/11.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D443
D447
D551
D597
B
B
B
B
12
24
12
24
14.2
27.5
14.2
27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-07Product Group 5/1/19979Page
![Page 12: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/12.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D551P
D597P
B
B
12
24
14.2
27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-08Product Group 5/1/199710Page
![Page 13: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/13.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D443P
D447P
B
B
12
24
14.2
27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-09Product Group11Page
![Page 14: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/14.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D437P
D559P
A
A
24
12
27.5
12.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-10Product Group12Page
![Page 15: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/15.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D437
D559
A
A
24
12
27.5
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked with (*) . Field lamp should turn off and the meter will indicate lowvoltage.
11/21/2014Revision: Date :D-11Product Group13Page
![Page 16: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/16.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D408XHD
D411XHD
*D440G
B
B
B
12
12
12
14.8
14.8
14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "STATOR". The indicator light will turn on, field lamp will stay on and meter willindicate approximately 12V. Disconnect the test lead from "L" terminal. Regulator will turn off and the meter will indicate 12V.To check for over Voltage, push the “Over Voltage” switch and the “Lamp Indicator” will turn on between 16.0V and 17.1V.Push the choke drive and the “Choke Drive Indicator Lamp” will turn on, if present.
NOTE: On D440 regulator, both of the "L" and "I" terminals must be connected in order to conduct the test.
11/21/2014Revision: Date :D-13Product Group 4/26/190514Page
![Page 17: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/17.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D412 *
D413
D440 **
D425
B
B
B
B
12
12
12
12
14.2
14.7
14.7
14.2
VOLTFLD SET POINTPART NO.
D446
D411SE
B
B
12
12
14.6
14.7
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "STATOR". The indicator light will turn on, field lamp will stay onand meter will indicate approximately 12V. Disconnect the test lead from "L" terminal. Regulator will turn off andthe meter will indicate 12V. On "I" type voltage regulators, connect the regulators as per diagram below except donot connect the indicator light to the "L" terminal. Connect red test lead to the terminal marked "I/F" and sameresults as step number 2 should be noticed.
*NOTE: On D412 regulator , an 1800 OHM pull-up resistor is required between "S" terminal of regulator and thetesters battery POS.**NOTE: On D440 regulator, both of the "L" and "I" terminals must be connected in order to conduct the test.
11/21/2014Revision: Date :D-14Product Group 4/26/190515Page
![Page 18: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/18.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D812
D817
D824
A
A
A
12
12
24
14.2
14.2
27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from the regulator's yellow wire. Field lamp should turn off and the meter will indicate lowvoltage. Also, connection the red test lead to "NO CONNECTION" terminal instead of regulator's red wire willresult in the same test data.
11/21/2014Revision: Date :D-15Product Group16Page
![Page 19: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/19.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D710
D713
D173L
B
B
B
6
12
12
7.8
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "stator". Field lamp should turn off and the meter will indicate lowvoltage. On D713L regulator, removal of white test leads will also cause indicator light to turn on.
11/21/2014Revision: Date :D-16Product Group 5/1/199717Page
![Page 20: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/20.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D590S
D591S
D593S
B
B
B
12
24
32
14.2
27.5
37.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-17Product Group18Page
![Page 21: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/21.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D812
D812HD
D813
D813HD
A
A
A
A
12
12
12
12
14.2
14.2
14.2
14.2
VOLTFLD SET POINTPART NO.
D824
D824HD
D832
A
A
A
24
24
32
27.5
27.5
37.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-18Product Group 5/1/199719Page
![Page 22: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/22.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D817
D817HD
A
A
12
12
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-19Product Group20Page
![Page 23: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/23.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D7018
D7019
A
A
12
24
14.2
27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from regulator's wire marked "stator". Field lamp should turn off and the meter willindicate low voltage.
11/21/2014Revision: Date :D-20Product Group 11/2/190321Page
![Page 24: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/24.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
DE606
DE607
A
A
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-21Product Group22Page
![Page 25: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/25.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D424 B 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "stator". The indicator light will turn on, field lamp will stay on andmeter will indicate approximately 12V. Disconnect the test lead from "L" terminal . Regulator will turn off and themeter will indicate 12V.
11/21/2014Revision: Date :D-23Product Group 3/8/199923Page
![Page 26: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/26.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D9206
D9207
B
B
6
6
7.8
7.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
On D9207, remove test lead from the terminal marked "STA". Field lamp will turn off , indicator light will turn on,and the meter will indicate low voltage.
11/21/2014Revision: Date :D-25Product Group24Page
![Page 27: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/27.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
DE611
DE615
A
A
12
12
14.7
14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-26Product Group 8/5/199725Page
![Page 28: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/28.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D7050 B 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "stator". Regulator will turn off and the meter will indicate 12V.
11/21/2014Revision: Date :D-27Product Group 9/12/199726Page
![Page 29: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/29.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
DE701
DE701HD
A
A
12
12
14.7
14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-28Product Group 10/20/199727Page
![Page 30: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/30.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D702XHD
D703XHD
D705XHD
D706XHD
B
B
B
B
12
12
12
12
14.5
14.5
14.7
14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "stator". The indicator light will turn on, field lamp will stay on andthe meter will indicate approximately 12 volts.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :D-29Product Group 4/26/190528Page
![Page 31: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/31.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D33
D22
A
A
12
12
14.1
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-30Product Group 10/26/190029Page
![Page 32: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/32.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D401 A 24 27.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-31Product Group 4/22/190330Page
![Page 33: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/33.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D698
D699
B
B
12
24
14.2
27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-32Product Group 11/28/190031Page
![Page 34: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/34.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D445 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "stator. The indicator light will turn on, field lamp will stay on andthe meter will indicate approximately 12 volts.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :D-33Product Group 4/26/190532Page
![Page 35: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/35.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D10AC
D22AC
B
B
12
12
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-37Product Group 11/27/190033Page
![Page 36: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/36.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D712
D718
D719
D729
B
B
B
B
12
12
12
12
14.6
14.7
14.75
14.75
VOLTFLD SET POINTPART NO.
D734
D749
D748
D752
B
B
B
B
12
12
12
12
14.6
14.6
14.8
14.7
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "stator". the indicator light will turn on, field lamp will stay on andmeter will indicate approximately 12v. Disconnect the test lead from "L" terminal. Regulator will turn off and themeter will indicate 12v. On "I" type voltage regulators, connect the regulators as per diagram below except do notconnect the indicator light to the "L" terminal. Connect red test lead to the terminal marked "I/F" and same resultsas step number 2 should be noticed.
11/21/2014Revision: Date :D-34Product Group 4/26/190534Page
![Page 37: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/37.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D198XHD
D200XHD
D201XHD
D202XHD
B
B
B
B
12
12
12
12
14.8
14.8
14.8
14.8
VOLTFLD SET POINTPART NO.
D203XHD B 12 14.8
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove Stator terminal, field light stays on voltage reads 12 volts and lamp light comes on. Remove lightterminal (and "I" terminal on PLIS type), voltage regulator turns off.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :D-35Product Group 4/26/190535Page
![Page 38: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/38.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F540
F540HD
F540S
F540SLD
B
B
B
B
12
12
12
12
14.3
14.2
14.3
14.2
VOLTFLD SET POINTPART NO.
F540SP
F540XHD
F782
F783
B
B
B
B
12
12
12
12
14.2
14.2
14.2
14.3
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red lead from terminal marked "S". Indicator light should turn on and meter will still indicate set pointvoltage. Removal of test lead from "S" and "I" terminal will result in the field lamp turning off and the meterreading 12V. On Mechanical type regulators (F8512M), the "short circuit" light will also turn on due to theregulator's internal circuitry. Limit this test to a short time.
11/21/2014Revision: Date :F-01Product Group36Page
![Page 39: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/39.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F784
F784HD
F794
F784B
A
A
A
A
12
12
12
12
14.6
14.6
14.6
14.6
VOLTFLD SET POINTPART NO.
F785
F786
F794B
F795
A
A
A
A
12
12
12
12
14.6
14.6
14.6
14.6
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Indicator light should turn on and the meter will still indicate theset point voltage. Removal of test of leads from "S" and " I" will result in field lamp turning off and the meterreading 12V.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
NOTE: On Transpo's F786 & F795 connect white test lead to terminal marked "S".
11/21/2014Revision: Date :F-03Product Group 4/26/190537Page
![Page 40: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/40.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F733L B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "stator". Field lamp should turn off and the meter will indicate lowvoltage. On F733L regulator, removal of white test lead will result in indicator light turning on.
* NOTE: No Yellow wire for F733
11/21/2014Revision: Date :F-05Product Group38Page
![Page 41: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/41.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
FB123
FB303
FB309
B
B
B
12
12
12
14.2
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from blue wire of the regulator. Field lamp should turn off and the meter will indicate 12V.
11/21/2014Revision: Date :F-06Product Group39Page
![Page 42: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/42.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F7078 B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked " Stator". Field lamp should turn off, indicator light will turn on andthe meter will indicate low voltage.
11/21/2014Revision: Date :F-07Product Group40Page
![Page 43: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/43.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F796 A 12.0 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :F-08Product Group 4/26/190541Page
![Page 44: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/44.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F600 A 12.0 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked “Stator”, field light stays on, voltage remains at 14.3 volt andindicator light turns on. Remove green test lead from “Light” terminal, field light and 12.0 volt light turn off.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :F-09Product Group 4/26/190542Page
![Page 45: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/45.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F798 A 12.0 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from stator and voltage will remain the same and 12 volt lamp will come on.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :F-10Product Group 4/26/190543Page
![Page 46: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/46.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F602
F603
F605
F606
A
A
A
A
12.0
12.0
12.0
12.0
14.4
14.4
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked “Stator”, field light stays ON. On F602 voltage drops to 12.0 volts and indicatorlight turns ON. On F603 voltage stays at 14.4 volts and lamp turns ON. Remove green test lead from “Light” terminal, fieldlight and lamp turn OFF.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V and 17.1V.Note: F605 Disconnect sense terminal, regulator should read aproximately 14.8V.
11/21/2014Revision: Date :F-11Product Group 8/30/190644Page
![Page 47: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/47.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHARLEY
VOLTFLD SET POINTPART NO.
H0478
H0482
A
A
12
12
15.1
15.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :H-01Product Group45Page
![Page 48: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/48.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHARLEY
VOLTFLD SET POINTPART NO.
H606
H614
A
A
6
12
7.5
15.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :H-02Product Group 5/28/190446Page
![Page 49: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/49.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB371 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-01Product Group 5/18/190547Page
![Page 50: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/50.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB8315 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-03Product Group48Page
![Page 51: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/51.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB303
IB303A
B
B
12
12
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-05Product Group49Page
![Page 52: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/52.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB375
IB376
IB377
IB378
A
A
A
A
12
24
12
12
14.4
27.5
14.4
14.4
VOLTFLD SET POINTPART NO.
IB379
IB374
A
A
24
24
28.1
27.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-06Product Group 10/20/199750Page
![Page 53: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/53.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB380
IB383
IB384
IB385
A
A
A
A
12
12
12
12
14.4
14.4
14.4
14.5
VOLTFLD SET POINTPART NO.
IB387 A 12 14.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-07Product Group 1/7/190251Page
![Page 54: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/54.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB033A B 24 28.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-08Product Group52Page
![Page 55: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/55.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB305
IB306
B
B
12
12
14.8
14.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
NOTE: IB306 Superseded by IB305-1
11/21/2014Revision: Date :IB-09Product Group 3/15/190253Page
![Page 56: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/56.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB308 B 24 28.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-10Product Group 5/20/190754Page
![Page 57: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/57.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB343 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "STA"; meter will indicate set point and lamp light will come on. Reconnect thewhite test lead. Remove red test lead from the terminal marked "SENSE", the meter will indicate 12V, field lamp will stay onand lamp light will come on. Remove green test lead; field and lamp light will turn off.To check for over Voltage, push the “Over Voltage” switch and the “Lamp Indicator” will turn on between 16.0V and 17.1V.
11/21/2014Revision: Date :IB-11Product Group 4/26/190555Page
![Page 58: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/58.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB348
IB350
IB351
IB352
A
A
A
A
12
12
12
12
15.0
14.1
14.5
14.1
VOLTFLD SET POINTPART NO.
IB353
IB354
IB355
IB356
A
A
A
A
12
12
12
12
14.5
14.1
14.5
14.8
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-12Product Group 3/26/190456Page
![Page 59: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/59.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB370
IB370A
A
A
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-13Product Group 3/26/190257Page
![Page 60: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/60.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB365 A 24 28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-14Product Group58Page
![Page 61: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/61.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB386 A 28 28
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-15Product Group59Page
![Page 62: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/62.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB398 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-16Product Group 10/20/199760Page
![Page 63: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/63.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB382
IB381
IB316
A
A
A
24
24
24
28.8
28.1
28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-17Product Group 8/30/190661Page
![Page 64: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/64.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB511 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-18Product Group 3/10/199962Page
![Page 65: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/65.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB512 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-19Product Group 3/9/199963Page
![Page 66: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/66.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB388 A 12 14.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-20Product Group 3/10/199964Page
![Page 67: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/67.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB501 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-21Product Group 12/3/199965Page
![Page 68: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/68.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB399 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-22Product Group 11/28/190066Page
![Page 69: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/69.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB400 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-23Product Group 11/28/190067Page
![Page 70: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/70.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB360
IB368
IB362
IB363
A
A
A
A
12
12
24
24
14.1
14.1
28.00
28.5
VOLTFLD SET POINTPART NO.
IB364
IB369
IB366-1
A
A
A
24
24
24
29.0
28.0
28.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-25Product Group 4/22/190368Page
![Page 71: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/71.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB225
IB247
A
A
12
12
14.5
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.• Push the Choke switch and the "Choke Drive" will turn on.• Remove white test lead from terminal marked "Stator" - the Field light and Lamp will come on and
Voltage will show 12 volts.• Remove green test lead from "light" terminal , field light will go out and voltage stays at 12 volts.
• To check IB247 for Over Voltage using VRC2010, push the “Over Voltage” switch and the “Lamp Indicator” willturn on between 16.0V and 17.1V.• L-FR Terminals • With LRC and Soft Start • Active Lamp Circuit - with OutputNOTE: VRC101-34 adapter shown for enhance stator signal, not all late model regulators need enhance signal
11/21/2014Revision: Date :IB-26Product Group 11/2/200369Page
![Page 72: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/72.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB392
IB391
A
A
12
12
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove Red test lead from terminal marked "STA". lamp comes on and the meter will indicate set point voltage.Reconnect the white test lead. Remove red test lead from the terminal marked "S", field lamp will turn on, theindicator light will turn on and the meter will indicate 12V.
11/21/2014Revision: Date :IB-04Product Group 4/26/190570Page
![Page 73: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/73.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO STAR II & STAR
VOLTFLD SET POINTPART NO.
D7011
D7012
D7014
D7016
B
B
B
B
6
8
12
24
7.8
9.6
14.2
27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect white test lead (Stator) from regulator's yellow wire. Field lamp should turn "OFF" and the meter willindicate the original voltage range in step one.
Note: Indicator light will turn "ON" on part numbers: D7011, D7014, D7016, D7041.
Regulator Wire Test Lead Wire FunctionRed Red Battery PositiveBlack Black Battery NegativeGreen Yellow FieldYellow White Stator
11/21/2014Revision: Date :ST-D-42Product Group71Page
![Page 74: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/74.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO STAR II & STAR
VOLTFLD SET POINTPART NO.
D7044
D7024
B
B
12
12
14.7
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect white test lead (Stator) from regulator's yellow wire. Field lamp should turn "OFF" and the meter willindicate the original voltage range in step one.
Note: Indicator light will turn "ON" on part numbers: D7044, D7021, D7024, D7026.
Regulator Wire Test Lead FunctionRed Red Battery PositiveBlack Black Battery NegativeGreen Yellow FieldYellow White Stator
11/21/2014Revision: Date :ST-D-43Product Group72Page
![Page 75: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/75.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB241 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "Stator" volts will drop to 12 volts; field light and lamp light willcome on. Remove green test lead from terminal marked "light", field and lamp light will go out and voltageremains at 12 volts.To check for over Voltage, push the “Over Voltage” switch and the “Lamp Indicator” will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IB-27Product Group 4/26/200573Page
![Page 76: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/76.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDUCELLIER
VOLTFLD SET POINTPART NO.
ID1006
ID1010
A
A
12
12
14.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from the blue wire of the regulator. Indicator light should turn on and the meter will stillindicate the set point voltage.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :ID-01Product Group 4/26/190574Page
![Page 77: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/77.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDUCELLIER
VOLTFLD SET POINTPART NO.
ID4009 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :ID-02Product Group 6/25/199875Page
![Page 78: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/78.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDUCELLIER
VOLTFLD SET POINTPART NO.
ID1015 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :ID-03Product Group 5/1/199776Page
![Page 79: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/79.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDUCELLIER
VOLTFLD SET POINTPART NO.
ID1004
ID1016
A
A
14
14
14.3
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect red test lead from stator (blue) wire indicator lamp will come on regulator will continue to read14.4/14.5 volts. Reconnect stator lead and lamp will go out.
11/21/2014Revision: Date :ID-04Product Group 5/1/199777Page
![Page 80: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/80.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDUCELLIER
VOLTFLD SET POINTPART NO.
ID1007 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect red test lead from stator (blue) wire indicator lamp will come on regulator will continue to read14.4/14.5 volts. Reconnect stator lead and lamp will go out.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :ID-05Product Group 4/26/190578Page
![Page 81: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/81.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDUCELLIER
VOLTFLD SET POINTPART NO.
ID1011 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect red test lead from stator (blue) wire indicator lamp will come on regulator will continue to read14.4/14.5 volts. Reconnect stator lead and lamp will go out.
11/21/2014Revision: Date :ID-06Product Group 5/1/199779Page
![Page 82: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/82.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDUCELLIER
VOLTFLD SET POINTPART NO.
ID1018 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from the blue wire of the regulator. Indicator light should turn on the meter will still indicatethe set point voltage.
11/21/2014Revision: Date :ID-07Product Group 5/1/199780Page
![Page 83: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/83.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFEMSA
VOLTFLD SET POINTPART NO.
IF8603
IF8607
A
A
12
12
14.7
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IF-01Product Group 5/1/199781Page
![Page 84: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/84.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFEMSA
VOLTFLD SET POINTPART NO.
IF5442 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red lead from terminal marked stator. Indicator light will come on, reconnect. Light shuts off.
11/21/2014Revision: Date :IF-02Product Group 3/12/199982Page
![Page 85: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/85.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFEMSA
VOLTFLD SET POINTPART NO.
IF1692 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IF-03Product Group 3/8/199983Page
![Page 86: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/86.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH605 B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from the terminal marked "STA". Warning light will turn on and meter should set pointvoltage.
11/21/2014Revision: Date :IH-01Product Group84Page
![Page 87: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/87.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH209
IH210
IH210HD
IH211
A
A
A
A
12
12
12
12
14.7
14.3
14.2
14.7
VOLTFLD SET POINTPART NO.
IH212
IH213
A
A
12
12
14.3
14.3
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IH-02Product Group85Page
![Page 88: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/88.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH201
IH202
IH203
A
A
A
12
12
12
14.3
14.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IH-03Product Group86Page
![Page 89: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/89.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH214
IH215
IH707
A
A
A
12
12
24
14.4
14.2
28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IH-04Product Group 10/27/190087Page
![Page 90: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/90.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH811
IH814
IH820
B
B
B
12
12
12
14.3
14.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove test lead from terminal marked "STA" Indicator light should turn on and the meter will still indicate theset point voltage.
11/21/2014Revision: Date :IH-05Product Group88Page
![Page 91: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/91.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH237
IH238
IH239
A
A
A
12
12
12
14.6
14.6
14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 15.5V.
11/21/2014Revision: Date :IH-06Product Group 10/27/190089Page
![Page 92: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/92.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH833 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove test lead from terminal marked "STA". Indicator light should turn on and the meter will still indicate theset point voltage.
11/21/2014Revision: Date :IH-07Product Group 10/20/199790Page
![Page 93: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/93.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH815
IH816
IH830
B
B
B
12
12
12
14.3
14.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove test lead from terminal marked "STA" Indicator light should turn on and the meter will still indicate the setpoint voltage.
11/21/2014Revision: Date :IH-08Product Group91Page
![Page 94: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/94.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH240 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S" Field lamp should still blink and the meter will indicateapproximately 15.5V.
11/21/2014Revision: Date :IH-09Product Group92Page
![Page 95: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/95.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH245 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal "S" Field lamp should still blink and the meter will indicate approximately 15.5V.
11/21/2014Revision: Date :IH-10Product Group93Page
![Page 96: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/96.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH241
IH244
A
A
12
12
14.6
14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 15.5V.
11/21/2014Revision: Date :IH-11Product Group94Page
![Page 97: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/97.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH243
IH246
A
A
12
12
14.6
14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 15.5V.
11/21/2014Revision: Date :IH-12Product Group95Page
![Page 98: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/98.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH242 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 15.5V.
11/21/2014Revision: Date :IH-13Product Group96Page
![Page 99: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/99.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH247 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "STA". Indicator light should turn on, field lamp will remain on andmeter will indicate approximately 12V. Remove red test lead from terminal marked "IG". Field lamp should turnoff.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IH-14Product Group 4/26/190597Page
![Page 100: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/100.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH248 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 15.5V.
11/21/2014Revision: Date :IH-15Product Group98Page
![Page 101: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/101.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH832 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove black test lead from terminal marked "STA". Indicator lamp should turn on and the meter will still indicatethe set point voltage.
11/21/2014Revision: Date :IH-16Product Group99Page
![Page 102: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/102.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH717 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IH-17Product Group 8/19/1902100Page
![Page 103: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/103.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH250 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 1 volt higher than set point.
11/21/2014Revision: Date :IH-18Product Group101Page
![Page 104: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/104.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH708 A 24 28.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect a red test lead to the terminal marked "C". The field lamp should still blink and the meter will indicateapproximately 26.3 V.
11/21/2014Revision: Date :IH-19Product Group102Page
![Page 105: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/105.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH760 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Filed lamp should still blink and the meter will indicateapproximately 15.5 volts.
11/21/2014Revision: Date :IH-20Product Group 9/1/1998103Page
![Page 106: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/106.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH761 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "Stator". 12V lamp should illuminate and the meter will indicateapproximately 12.0 V.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IH-21Product Group 4/26/1905104Page
![Page 107: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/107.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH249 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should blink and the meter will indicate approximately15.5V.
11/21/2014Revision: Date :IH-22Product Group 10/20/1997105Page
![Page 108: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/108.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH251 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should blink and the meter will indicate approximately15.5V.
11/21/2014Revision: Date :IH-23Product Group106Page
![Page 109: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/109.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH252 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove sense. Voltage goes to 15.6V and field light stays on.
11/21/2014Revision: Date :IH-24Product Group 9/1/1998107Page
![Page 110: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/110.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH762 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "STA". Field lamp will remain fully on and the meter should indicate12V.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IH-25Product Group 4/26/1905108Page
![Page 111: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/111.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH765
IH767
A
A
12
12
14.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "Stator". 12V lamp should illuminate and the meter will indicateapproximately 12 volts.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IH-26Product Group 4/26/1905109Page
![Page 112: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/112.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH205 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove (Red) Sense lead, voltage should go to 15.5V.
11/21/2014Revision: Date :IH-27Product Group 8/23/1999110Page
![Page 113: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/113.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH254 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove (Red) lead from sense , Field lamp will stay on, voltage will rise between 15.5V and 15.9V.
11/21/2014Revision: Date :IH-28Product Group 8/24/1999111Page
![Page 114: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/114.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH766 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect "S", Voltage stays the same , 12V lamp comes on and field lamp continues to be on and field lampcontinues to be on.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IH-29Product Group 4/26/1905112Page
![Page 115: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/115.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH770 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect "S", voltage goes to approximately 15.2V Field lamp stays on.
11/21/2014Revision: Date :IH-30Product Group 11/28/1900113Page
![Page 116: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/116.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH776 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white lead from stator, field circuit lamp will stay on. 12V lamp will come on and voltage will drop to 12V.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IH-31Product Group 4/26/1905114Page
![Page 117: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/117.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH782 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect (white ) lead from stator, voltage drops to 12V and lamp comes on. Disconnect (Red) lead fromsense, lamp comes on and rises to 15.5V.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IH-32Product Group 4/26/1905115Page
![Page 118: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/118.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH763 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red lead from terminal marked "S" and voltage will rise to approximately 15.5V. Remove stator and lampcomes on and voltage drops to 12V.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IH-33Product Group 4/26/1905116Page
![Page 119: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/119.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH772 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove stator and lamp comes on. Apply ground to "C" Terminal and voltage will drop to 12.5 volts.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.
11/21/2014Revision: Date :IH-34Product Group 4/26/1905117Page
![Page 120: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/120.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsISKRA
VOLTFLD SET POINTPART NO.
IK404 A 24 28.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IK-01Product Group 3/12/1999118Page
![Page 121: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/121.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsISKRA
VOLTFLD SET POINTPART NO.
IK401 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IK-02Product Group 3/12/1999119Page
![Page 122: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/122.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLUCAS
VOLTFLD SET POINTPART NO.
IL211
IL213
IL217
A
A
A
12
12
12
14.2
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IL-01Product Group 5/1/1997120Page
![Page 123: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/123.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLUCAS
VOLTFLD SET POINTPART NO.
IL214
IL215
IL216
IL218
A
A
A
A
12
12
12
12
14.2
14.2
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IL-02Product Group 5/1/1997121Page
![Page 124: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/124.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLUCAS
VOLTFLD SET POINTPART NO.
IL223
IL225
IL223CN-B128
A
A
A
12
24
12
14.3
28.1
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IL-03Product Group 5/1/1997122Page
![Page 125: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/125.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLUCAS
VOLTFLD SET POINTPART NO.
IL224 A 12 12.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IL-04Product Group 5/1/1997123Page
![Page 126: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/126.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLUCAS
VOLTFLD SET POINTPART NO.
IL219
IL220
IL221
IL222
A
A
A
A
12
12
12
12
14.3
14.3
12.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IL-05Product Group124Page
![Page 127: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/127.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLUCAS
VOLTFLD SET POINTPART NO.
IL1292 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IL-06Product Group 11/29/1900125Page
![Page 128: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/128.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM204
IM204HD
IM205
IM225
A
A
A
A
12
12
12
12
14.6
14.6
14.6
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
On IM225 regulator, remove red test lead from terminal marked "*". Field lamp should still blink and the meterwill indicate approximately 15.4V.
11/21/2014Revision: Date :IM-01Product Group 8/15/1997126Page
![Page 129: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/129.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM224 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect another black test lead to terminal marker "Quick Start". Field lamp should still blink and the meter willindicate approximately 13.0V.
11/21/2014Revision: Date :IM-02Product Group127Page
![Page 130: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/130.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM216
IM216HD
IM289
IM217HD
A
A
A
A
12
12
12
12
14.5
14.5
14.5
14.3
VOLTFLD SET POINTPART NO.
IM217 A 12 14.3
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
On IM217 Regulator, remove red test lead from terminal marked "*". Field lamp should still blink and the meterwill indicate approximately 15.4V.
11/21/2014Revision: Date :IM-03Product Group 8/7/1998128Page
![Page 131: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/131.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM268
IM270
A
A
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
On IM268, removal of red test lead from terminal marked "A" should result in the indicator light to turn on and themeter will indicate approximately 15.7V. On IM270, Removal of test lead "A" terminal should result in the meterto indicate approximately 15.7V.
11/21/2014Revision: Date :IM-04Product Group129Page
![Page 132: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/132.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM542
IM951
IM954
IM952
B
B
B
B
12
12
12
12
14.3
14.3
14.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove Red test lead from terminal marked "STA". Indicator light should turn on and the meter will indicate theset point voltage.
11/21/2014Revision: Date :IM-05Product Group130Page
![Page 133: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/133.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM261
IM269
A
A
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
On IM261, remove red test lead from the terminal marked "*". Field lamp should still blink and the meter willindicated approximately 15.4 v.
IM261: S-L TerminalsIM269: R-L Terminals
11/21/2014Revision: Date :IM-06Product Group131Page
![Page 134: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/134.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM604 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "STA". Indicator light should turn on and the meter will indicate setpoint voltage.
11/21/2014Revision: Date :IM-07Product Group 10/20/1904132Page
![Page 135: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/135.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM262
IM263
IM265
IM265HD
A
A
A
A
12
12
12
12
14.5
14.5
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 1.5V above the set point voltage.
11/21/2014Revision: Date :IM-08Product Group133Page
![Page 136: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/136.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM266
IM266HD
A
A
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-09Product Group134Page
![Page 137: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/137.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM267 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "C" and connect a black test lead to it . Field lamp should still blinkand the meter will indicate approximately 12.5V.
11/21/2014Revision: Date :IM-10Product Group135Page
![Page 138: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/138.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM271 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink, indicator light turn on and the meterwill indicate approximately 15.5V.
11/21/2014Revision: Date :IM-11Product Group136Page
![Page 139: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/139.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM272 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "A". Field lamp should still blink , indicator light will turn on and themeter will indicate approximately 15.5V.
11/21/2014Revision: Date :IM-12Product Group137Page
![Page 140: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/140.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM274 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 15.5V.
11/21/2014Revision: Date :IM-13Product Group138Page
![Page 141: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/141.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM277
IM278
IM279
A
A
A
12
12
12
14.5
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 15.5V. (on IM277 & IM279 indicator light will turn on.)
11/21/2014Revision: Date :IM-14Product Group139Page
![Page 142: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/142.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM226 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-15Product Group140Page
![Page 143: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/143.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM215 A 24 28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-16Product Group141Page
![Page 144: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/144.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM227 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-17Product Group142Page
![Page 145: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/145.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM207
IM213
A
A
12
24
14.5
28.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-18Product Group143Page
![Page 146: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/146.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM212
IM208
A
A
24
12
28.4
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-19Product Group144Page
![Page 147: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/147.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM214 A 24 28.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-20Product Group145Page
![Page 148: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/148.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM206 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-21Product Group146Page
![Page 149: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/149.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM273
IM839
IM835
A
A
A
12
12
12
14.4
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "TRIO". field lamp should still blink indicator light will turn on andmeter will indicate the set point voltage.
Reconnect red test lead to terminal marked "Trio". Connect black test lead to "C" terminal. Field lamp should stillblink and meter will indicate approximately 12.5V.
11/21/2014Revision: Date :IM-22Product Group 4/26/1905147Page
![Page 150: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/150.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM282
IM281
A
A
12
12
14.4
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". field lamp should still blink and the meter will indicatedapproximately 15.5V.
11/21/2014Revision: Date :IM-23Product Group148Page
![Page 151: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/151.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM280
IM837
A
A
12
12
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S" Indicator lamp should turn on, will still blink, and the meter willindicate approximately 15.5V.Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.
11/21/2014Revision: Date :IM-24Product Group 4/26/1905149Page
![Page 152: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/152.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM209 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S" field lamp will still blink, and the meter will indicate approximately15.5V.
11/21/2014Revision: Date :IM-26Product Group150Page
![Page 153: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/153.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM210 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp will still blink, and the meter will indicateapproximately 15.5V.
11/21/2014Revision: Date :IM-27Product Group151Page
![Page 154: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/154.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM276 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Indicator light will turn on, Field lamp will still blink, and themeter will indicate approximately 15.5V.
11/21/2014Revision: Date :IM-28Product Group152Page
![Page 155: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/155.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM287 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". The meter will indicate approximately 15.5V.
11/21/2014Revision: Date :IM-29Product Group153Page
![Page 156: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/156.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM283 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-30Product Group 3/8/1999154Page
![Page 157: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/157.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM829 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Indicator lamp should turn on, field lamp will still blink, and themeter will indicate approximately 15.5V.
11/21/2014Revision: Date :IM-31Product Group 6/8/1999155Page
![Page 158: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/158.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM830 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Indicator lamp should turn on, field lamp will still blink, and themeter will indicate approximately 15.5V. and the lamp will turn on.
11/21/2014Revision: Date :IM-32Product Group 10/27/1900156Page
![Page 159: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/159.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM285 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 15.5 volts.
11/21/2014Revision: Date :IM-33Product Group 10/27/1900157Page
![Page 160: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/160.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM288 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 15.5V.
11/21/2014Revision: Date :IM-34Product Group158Page
![Page 161: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/161.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM291 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S" Indicator lamp should turn on, field lamp will still blink, and themeter will indicate approximately 15.5V.
11/21/2014Revision: Date :IM-35Product Group159Page
![Page 162: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/162.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM292 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S" field lamp will still blink, and the meter will indicate approximately15.5V.
11/21/2014Revision: Date :IM-36Product Group 12/12/1900160Page
![Page 163: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/163.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM832 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Indicator lamp should turn on, field lamp will still blink, and themeter will indicate approximately 15.5V.
11/21/2014Revision: Date :IM-37Product Group161Page
![Page 164: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/164.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM275
IM834
A
A
12
12
14.7
14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-38Product Group 8/24/1999162Page
![Page 165: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/165.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM836 A 14 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "A". Field lamp should still blink, indicator light will turn on and themeter will indicate approximately 15.5V.
11/21/2014Revision: Date :IM-39Product Group 8/6/1999163Page
![Page 166: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/166.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM290 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-40Product Group 8/31/1999164Page
![Page 167: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/167.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM830HD A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink, indicator light will turn on and themeter will indicate approximately 15.5 volts.
11/21/2014Revision: Date :IM-41Product Group 8/6/1999165Page
![Page 168: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/168.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM840 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red sense lead & indicator light will turn on & Voltage will rise to 15.5 volts.
11/21/2014Revision: Date :IM-42Product Group 10/1/1998166Page
![Page 169: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/169.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM293 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-43Product Group 3/8/1999167Page
![Page 170: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/170.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM831 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicateapproximately 15.5 volts.
11/21/2014Revision: Date :IM-44Product Group 3/9/1999168Page
![Page 171: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/171.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM845 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect sense & voltage should rise to approximately 15.5 volts and light come on. Reconnect sense.Connect black test lead to "C", voltage should drop to approximately 12.5 volts.Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.
11/21/2014Revision: Date :IM-45Product Group 4/26/1905169Page
![Page 172: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/172.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM286
IM294
A
A
24
12
28.7
14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-46Product Group 8/25/1999170Page
![Page 173: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/173.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM318 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.
11/21/2014Revision: Date :IM-47Product Group 4/26/1905171Page
![Page 174: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/174.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM850 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect "C" terminal to tester, push Computer button and voltage will drop to approximately 12.5V. field lampstays on.Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.
11/21/2014Revision: Date :IM-48Product Group 4/26/1905172Page
![Page 175: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/175.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM232 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-49Product Group 11/22/1900173Page
![Page 176: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/176.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM211 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-50Product Group 12/15/1999174Page
![Page 177: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/177.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM381 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead and lamp comes on, voltage drops to 12.0 volts and field light stays on . Remove greentest lead from light and field light goes off.Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.
11/21/2014Revision: Date :IM-51Product Group 4/26/1905175Page
![Page 178: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/178.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN209
IN210
A
A
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-01Product Group 3/26/1998176Page
![Page 179: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/179.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN234 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp will still blink, and the meter will indicateapproximately 15.0V.
11/21/2014Revision: Date :IN-02Product Group177Page
![Page 180: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/180.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN229
IN229HD
A
A
12
12
14.1
14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
NOTE: When testing the Transpo IN229 or the Original Equipment voltage regulators, the short circuit light mayflash and the meter will indicate the set point voltage.
11/21/2014Revision: Date :IN-03Product Group 3/12/1999178Page
![Page 181: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/181.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN218
IN217
A
A
12
24
14.2
27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "B+.". The meter should indicate approximately 17V on the IN218regulator and 28V on the IN236 regulator.
11/21/2014Revision: Date :IN-04Product Group179Page
![Page 182: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/182.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN235 A 12 14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-05Product Group 3/12/1999180Page
![Page 183: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/183.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN231
IN232
A
A
12
12
14.4
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-06Product Group181Page
![Page 184: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/184.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN223 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove test lead from terminal marked "P" Indicator light should turn on, field lamp will remain on, and the meterwill indicate approximately 12.0V.
11/21/2014Revision: Date :IN-07Product Group182Page
![Page 185: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/185.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN550 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-08Product Group183Page
![Page 186: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/186.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN551
IN558
IN560
IN562
B
B
B
B
12
12
12
12
14.3
14.3
14.3
14.3
VOLTFLD SET POINTPART NO.
IN822
IN579
B
B
12
12
14.3
14.3
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove black test lead from terminal marked "STA". Indicator light should turn on and the meter will indicate theset point voltage.
11/21/2014Revision: Date :IN-09Product Group 10/20/1997184Page
![Page 187: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/187.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN569
IN578
IN589
B
B
B
12
12
12
14.3
14.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove black test lead from terminal marked "STA". Indicator light should turn on and the meter will indicate theset point voltage.
11/21/2014Revision: Date :IN-10Product Group185Page
![Page 188: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/188.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN233 A 24 28
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-11Product Group186Page
![Page 189: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/189.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN441 A 14 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked Stator. Indicator light will turn on and meter will indicate 12V; Fieldcircuit light stays on. Reconnect. Remove red test lead from terminal marked "IG"; field lamp should turn offmeter will indicate 12V.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
NOTE on Stator: Transpo (White test lead) / OE (Red test lead)
11/21/2014Revision: Date :IN-12Product Group 4/26/1905187Page
![Page 190: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/190.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN442 A 12 14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked stator. Indicator light will come on.
11/21/2014Revision: Date :IN-13Product Group 10/20/1997188Page
![Page 191: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/191.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN601 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-15Product Group189Page
![Page 192: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/192.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN602 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove black test lead from terminal marked "STA". Indicator light turn on and the meter will indicator lightshould turn on and the meter will indicate the set point voltage.
11/21/2014Revision: Date :IN-16Product Group190Page
![Page 193: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/193.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN567 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-20Product Group191Page
![Page 194: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/194.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN8315 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-21Product Group192Page
![Page 195: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/195.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN554 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-22Product Group193Page
![Page 196: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/196.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN228 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-23Product Group194Page
![Page 197: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/197.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN230 A 12 14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Indicator light will come on and voltage will rise to approximately16 volts.
NOTE: When testing the Transpo IN230 or the Original Equipment voltage regulators, the short circuit light mayflash and the meter will indicate the set point voltage.
11/21/2014Revision: Date :IN-24Product Group195Page
![Page 198: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/198.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN568 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-25Product Group196Page
![Page 199: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/199.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN821 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove black test lead from the terminal marked "STA". The indicator light should turn on and the meter willindicate the set point voltage.
11/21/2014Revision: Date :IN-26Product Group197Page
![Page 200: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/200.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN220
IN226
IN250
IN256
A
A
A
A
12
12
12
12
14.4
14.4
14.4
14.4
VOLTFLD SET POINTPART NO.
IN436
IN437
IN439
IN444
A
A
A
A
12
12
12
12
14.0
14.4
14.4
14.4
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove test lead from the terminal marked "*". The indicator light will turn on and the meter will indicateapproximately 12V and the field lamp will remain fully on (this is the soft start mode of the regulator).To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.
NOTE on Stator: Transpo (White test lead) / OE (Red test lead)
11/21/2014Revision: Date :IN-27Product Group 4/26/1905198Page
![Page 201: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/201.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN434
IN438
A
A
12
12
14.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove test lead from the terminal marked "*". The indicator light will turn on and the meter will indicateapproximately 12V and the field lamp will remain fully on (this is the soft start mode of the regulator).To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
NOTE on Stator: Transpo (White test lead) / OE (Red test lead)
11/21/2014Revision: Date :IN-28Product Group 4/26/1905199Page
![Page 202: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/202.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN920 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove the white test lead from the terminal marked stator, the indicator light will turn on and the meter willindicate approximately 12V. The field lamp will remain fully on . (This is the soft -start mode of the regulator)
NOTE: Transpo (White test lead) / OE (Red test lead)
11/21/2014Revision: Date :IN-30Product Group200Page
![Page 203: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/203.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN555 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove the white test lead from the terminal marked stator, The indicate approximately 12V. The field lamp willremain fully on, (This is the soft-start mode of the regulator.)
11/21/2014Revision: Date :IN-31Product Group 10/20/1997201Page
![Page 204: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/204.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN220E A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove test lead from the terminal marked "*". The indicator light will turn on and the meter will indicateapproximately 14.6v. and the field lamp will remain fully on.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.
11/21/2014Revision: Date :IN-32Product Group 4/26/1905202Page
![Page 205: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/205.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN450 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
* NOTE: On OE Regulator connect a Red test lead to stator (STA)
11/21/2014Revision: Date :IN-34Product Group 3/5/2010203Page
![Page 206: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/206.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN445 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
* With regulator ‘ON’, connect "C" terminal to tester, push Computer button on tester and Voltage should drop to12.5 volts.To check for over Voltage, push the "Over Voltage" button and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IN-35Product Group 4/26/1905204Page
![Page 207: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/207.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN453 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white lead from stator and voltage should drop to 12.0V and 12V lamp should come on. Field circuitlamp stays on.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IN-36Product Group 4/26/1905205Page
![Page 208: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/208.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN455 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S" and lamp turns on and voltage remains the same.
11/21/2014Revision: Date :IN-37Product Group 11/28/1900206Page
![Page 209: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/209.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN277 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect “Stator” terminal, “Light” comes on, voltage goes to 12 Volts and field light stays on. Remove “Light”terminal, Volts will read 12 Volts and field light will go off.
11/21/2014Revision: Date :IN-39Product Group 5/2/1905207Page
![Page 210: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/210.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPARIS RHONE
VOLTFLD SET POINTPART NO.
IP125
IP126
IP955
IP125NV
A
A
A
A
12
24
24
12
14.6
28.4
28.4
14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IP-01Product Group 7/8/1998208Page
![Page 211: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/211.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPARIS RHONE
VOLTFLD SET POINTPART NO.
IP127 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IP-02Product Group209Page
![Page 212: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/212.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPARIS RHONE
VOLTFLD SET POINTPART NO.
IP135
IP135B
IP129B
A
A
A
12
12
24
14.3
14.3
27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IP-03Product Group210Page
![Page 213: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/213.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPARIS RHONE
VOLTFLD SET POINTPART NO.
IP122
IP152
IP1639
IP1655
A
A
A
A
12
12
12
12
14.4
14.2
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove black test lead from the blue wire of the regulator . Indicator light should turn on and meter will stillindicate the set point voltage.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IP-04Product Group 4/26/1905211Page
![Page 214: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/214.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPARIS RHONE
VOLTFLD SET POINTPART NO.
IP137
IP1903
IP2700
A
A
A
12
12
12
14.6
14.6
14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IP-05Product Group212Page
![Page 215: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/215.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPARIS RHONE
VOLTFLD SET POINTPART NO.
IP735B
IP729B
A
A
12
12
14.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IP-06Product Group 10/10/1902213Page
![Page 216: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/216.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPARIS RHONE
VOLTFLD SET POINTPART NO.
IP130 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from the stator wire of the regulator. indicator light should turn on and meter will stillindicate the set point voltage.
11/21/2014Revision: Date :IP-07Product Group214Page
![Page 217: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/217.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPARIS RHONE
VOLTFLD SET POINTPART NO.
IP1926 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IP-08Product Group 3/8/1999215Page
![Page 218: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/218.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPARIS RHONE
VOLTFLD SET POINTPART NO.
IP736 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IP-09Product Group 3/10/1999216Page
![Page 219: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/219.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPARIS RHONE
VOLTFLD SET POINTPART NO.
IP123 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove black test lead from blue wire. Indicator light should turn on and voltage will remain the same.
11/21/2014Revision: Date :IP-10Product Group 4/14/1999217Page
![Page 220: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/220.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPARIS RHONE
VOLTFLD SET POINTPART NO.
IP1652 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from the blue wire of the regulator. Indicator light should turn on and meter will readapproximately 12 volts.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IP-11Product Group 4/26/1905218Page
![Page 221: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/221.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLADA
VOLTFLD SET POINTPART NO.
IR674 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IR-01Product Group219Page
![Page 222: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/222.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsSEV MARCHAL
VOLTFLD SET POINTPART NO.
IS219
IS219A
B
B
12
12
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IS-01Product Group220Page
![Page 223: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/223.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsSEV MARCHAL
VOLTFLD SET POINTPART NO.
IS222 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IS-02Product Group 10/27/1900221Page
![Page 224: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/224.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsSEV MARCHAL
VOLTFLD SET POINTPART NO.
IS301 B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IS-03Product Group222Page
![Page 225: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/225.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsSEV MARCHAL
VOLTFLD SET POINTPART NO.
IS223 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IS-04Product Group 10/27/1900223Page
![Page 226: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/226.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI-MARELLI
VOLTFLD SET POINTPART NO.
IX106
IX107
IX108
IX109
A
A
A
A
12
12
24
24
14.2
14.2
28.0
28.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IX-01Product Group 11/22/1900224Page
![Page 227: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/227.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI-MARELLI
VOLTFLD SET POINTPART NO.
IX110
IX111
A
A
12
24
14.5
28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IX-02Product Group225Page
![Page 228: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/228.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI-MARELLI
VOLTFLD SET POINTPART NO.
IX4004 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IX-03Product Group 3/8/1999226Page
![Page 229: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/229.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI-MARELLI
VOLTFLD SET POINTPART NO.
IX121 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from stator terminal. Indicator light will come on. Field light will stay on and meter willread approximately 12 volts.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IX-04Product Group 4/26/1905227Page
![Page 230: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/230.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI-MARELLI
VOLTFLD SET POINTPART NO.
IX127
IX128
A
A
12
12
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from stator terminal . Indicator light will come on. Field light will stay on and meter willread approximately 12 volts.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IX-05Product Group 4/26/1905228Page
![Page 231: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/231.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI-MARELLI
VOLTFLD SET POINTPART NO.
IX123
IX123S-B64
A
A
12
12
14.1
14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from stator terminal. Indicator light will come on. Field light will stay on and meter willread approximately 12 volts.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.
11/21/2014Revision: Date :IX-06Product Group 2/14/1906229Page
![Page 232: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/232.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI-MARELLI
VOLTFLD SET POINTPART NO.
IX118 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red lead from stator and voltage will remain the same. Field lamp will flicker and 12V lamp come on.
11/21/2014Revision: Date :IX-07Product Group 4/14/1999230Page
![Page 233: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/233.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMANDO
VOLTFLD SET POINTPART NO.
IY785
IY786
A
A
12
12
14.6
14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IY-01Product Group231Page
![Page 234: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/234.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMANDO
VOLTFLD SET POINTPART NO.
IY510 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IY-02Product Group 3/9/1999232Page
![Page 235: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/235.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMANDO
VOLTFLD SET POINTPART NO.
IY422 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect sense (Red) lead, voltage should go to 15.5V.
11/21/2014Revision: Date :IY-03Product Group 8/25/1999233Page
![Page 236: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/236.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMANDO
VOLTFLD SET POINTPART NO.
IY058 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from "S" terminal. Voltage will go up to approximately 15.5V.
11/21/2014Revision: Date :IY-04Product Group 2/20/1902234Page
![Page 237: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/237.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIKKO
VOLTFLD SET POINTPART NO.
IZ226
IZ227
A
A
24
12
27.5
14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IZ-01Product Group235Page
![Page 238: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/238.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE NEVILLE
VOLTFLD SET POINTPART NO.
L79000
L79000HD
L79000HDP
L79000LH
A
A
A
A
12
12
12
12
14.2
14.2
14.2
14.2
VOLTFLD SET POINTPART NO.
L79000S
L79000X
L95019
L96852
A
A
A
A
12
12
12
24
14.2
14.2
14.2
27.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from regulator wire marked "TRIO". Filed lamp should turn off and the meter will indicatelow voltage.
11/21/2014Revision: Date :L-01Product Group 10/30/1900236Page
![Page 239: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/239.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE NEVILLE
VOLTFLD SET POINTPART NO.
L79350S
L97050S
A
A
24
32
27.5
37.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from regulator wire marked "TRIO". Filed lamp should turn off and the meter will indicatelow voltage.
11/21/2014Revision: Date :L-02Product Group 10/30/1900237Page
![Page 240: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/240.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE NEVILLE
VOLTFLD SET POINTPART NO.
L79000AC
L96345AC
A
A
12
12
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from regulator wire marked "Stator". Filed lamp should turn off and the meter will indicatelow voltage.
11/21/2014Revision: Date :L-03Product Group238Page
![Page 241: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/241.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE NEVILLE
VOLTFLD SET POINTPART NO.
L95300S
L99500S
L99825S
L99850S
A
A
A
A
24
12
24
32
28.0
14.2
27.5
37.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
NOTE: Connect B+ to the three stator Terminals if no IGN terminal is used
11/21/2014Revision: Date :L-04Product Group239Page
![Page 242: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/242.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE NEVILLE
VOLTFLD SET POINTPART NO.
L77973AC
L97300AC
A
A
12
12
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from the regulator's stud marked "Stator". Field lamp should turn off and the meter willindicate low voltage.
11/21/2014Revision: Date :L-05Product Group240Page
![Page 243: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/243.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE NEVILLE
VOLTFLD SET POINTPART NO.
L77973S
L78855S
L78935S
L97300S
A
A
A
A
12
24
32
12
14.2
27.5
37.5
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from regulator's stud marked "TRIO" or "IGN". Field lamp should turn off and the meterwill indicate low voltage.
11/21/2014Revision: Date :L-06Product Group241Page
![Page 244: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/244.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE NEVILLE
VOLTFLD SET POINTPART NO.
L5022
L5042
L5062
L5078
A
A
A
A
12
24
32
12
14.2
27.5
37.5
14.2
VOLTFLD SET POINTPART NO.
L5042HD A 24 27.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :L-07Product Group242Page
![Page 245: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/245.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE NEVILLE
VOLTFLD SET POINTPART NO.
L5016
L5028
B
B
12
12
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :L-08Product Group243Page
![Page 246: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/246.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE NEVILLE
VOLTFLD SET POINTPART NO.
L5003 B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :L-10Product Group244Page
![Page 247: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/247.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE NEVILLE
VOLTFLD SET POINTPART NO.
L99920
L99920HD
A
A
12
12
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from “Stator” terminal and regulator turns off.
11/21/2014Revision: Date :L-11Product Group 11/22/1900245Page
![Page 248: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/248.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-156A
M5-157A
M5-161A
M5-163A
B
B
B
B
12
24
24
24
14.2
29.2
28.4
28.0
VOLTFLD SET POINTPART NO.
M5-177A
M5-191A
M5-211A
M5-232A
B
B
B
B
24
12
12
12
28.0
14.2
14.2
14.4
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-02Product Group246Page
![Page 249: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/249.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-239A
M5-274A
B
B
12
36
13.8
38.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-03Product Group247Page
![Page 250: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/250.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-130A
M5-130
B
B
12
12
15.2
15.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
NOTE: * Regulators with One (1) yellow wire: M5-30A, M5-42A, M5-130A, M5-135, M5-141A** Regulators with Two (2) yellow wires: M5-28A, M5-50A
11/21/2014Revision: Date :M5-04Product Group248Page
![Page 251: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/251.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-143A
M5-150A
M5-206A
M5-218A
B
B
B
B
12
12
12
12
14.2
14.2
15.3
15.3
VOLTFLD SET POINTPART NO.
M5-222A
M5-185A
B
B
12
24
15.3
29.2
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
NOTE: * Regulators with One (1) Yellow wire: M5-143A, M5-150A, M5-206A, M5-218A, M5-222A, M5-185A
11/21/2014Revision: Date :M5-05Product Group249Page
![Page 252: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/252.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-137A
M5-142A
M5-184A
B
B
B
12
12
24
15.2
14.2
29.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-07Product Group250Page
![Page 253: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/253.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-113A
M5-122A
M5-216A
B
B
B
12
12
12
14.2
14.4
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from yellow wire of the regulator. Indicator light should turn on and the meter will indicatethe set point voltage.
11/21/2014Revision: Date :M5-08Product Group251Page
![Page 254: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/254.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-204A B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked with "*". Field lamp should still blink and the meter will indicateapproximately 15.3 v.
11/21/2014Revision: Date :M5-09Product Group252Page
![Page 255: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/255.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-228A
M5-138A
M5-174A
M5-205A
B
B
B
B
12
12
12
12
14.1
15.2
14.1
14.1
VOLTFLD SET POINTPART NO.
M5-223A B 12 13.8
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-10Product Group253Page
![Page 256: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/256.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-230A B 12 14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-11Product Group254Page
![Page 257: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/257.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-196A B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-12Product Group255Page
![Page 258: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/258.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-159A
M5-227A
B
B
24
12
29.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-13Product Group256Page
![Page 259: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/259.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-146
M5-146A
B
B
12
12
15.2
15.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-16Product Group257Page
![Page 260: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/260.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-197A
M5-207A
M5-250A
B
B
B
12
12
12
15.0
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-19Product Group258Page
![Page 261: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/261.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-198A
M5-200A
M5-244A
B
B
B
12
12
12
15.0
14.2
13.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-20Product Group259Page
![Page 262: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/262.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-200SA6
M5-200SA8
M5-200SA12
M5-200SA24
B
B
B
B
6
8
12
24
7.8
9.5
14.2
27.5
VOLTFLD SET POINTPART NO.
M5-200SA32 B 32 37.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from the yellow wire of the regulator marked "Stator ". Field lamp should turn off and themeter will indicate low voltage. On regulators with indicator light, light should also turn on when stator is removedfrom the regulator.
* NOTE: Not used on 24V & 32V Regulators
11/21/2014Revision: Date :M5-21Product Group260Page
![Page 263: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/263.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-226A A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-22Product Group261Page
![Page 264: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/264.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-208A
M5-209A
B
B
24
24
29.2
28.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Measure between regulator's yellow and red wire using an ohm meter (without a connection to the voltageregulator tester). Approximately 150 Ohms must be measured.
11/21/2014Revision: Date :M5-23Product Group262Page
![Page 265: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/265.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-225A
M5-225
A
A
12
12
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-24Product Group 7/29/1997263Page
![Page 266: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/266.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-217A B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-25Product Group264Page
![Page 267: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/267.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-203A B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-26Product Group265Page
![Page 268: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/268.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-233A B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and themeter will indicate low voltage.
11/21/2014Revision: Date :M5-27Product Group 9/12/1994266Page
![Page 269: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/269.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-224A
M5-245A
B
B
12
12
14.4
13.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and themeter will indicate low voltage.
11/21/2014Revision: Date :M5-28Product Group 9/12/1997267Page
![Page 270: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/270.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-181A
M5-192A
M5-201A
B
B
B
12
12
12
15.0
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-29Product Group268Page
![Page 271: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/271.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-172A
M5-169A
B
B
12
12
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-30Product Group269Page
![Page 272: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/272.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-149A B 24 28.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". field lamp should still blink and the meter will indicateapproximately 29.5v.
11/21/2014Revision: Date :M5-31Product Group270Page
![Page 273: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/273.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-215A A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-32Product Group271Page
![Page 274: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/274.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-193A
M5-214A
M5-240A
B
B
B
12
12
12
14.4
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-33Product Group 8/23/1999272Page
![Page 275: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/275.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-237A B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from stator wires. The field lamp should stay on and the meter will indicate high voltage.Connect red test lead to the post marked "no connection". Regulator will regulate at the specified set pointvoltage.
11/21/2014Revision: Date :M5-34Product Group 9/12/1997273Page
![Page 276: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/276.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-292A A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "Stator". Field lamp should turn off and the meter will indicateapproximately 12v.
11/21/2014Revision: Date :M5-35Product Group 3/12/1999274Page
![Page 277: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/277.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-329A A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-36Product Group 8/25/1998275Page
![Page 278: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/278.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-247A B 24 27.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and themeter will indicate low voltage.
NOTE: Original Equipment Regulator no. 5-247 is an "A" circuit compared to Transpo's "B" circuit.
11/21/2014Revision: Date :M5-37Product Group276Page
![Page 279: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/279.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-249A B 24 28.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and themeter will indicate low voltage.
NOTE: Original Equipment Regulator no. 5-249 is an "A" circuit compared to Transpo's "B" circuit.
11/21/2014Revision: Date :M5-38Product Group277Page
![Page 280: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/280.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-050A A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and themeter will indicate low voltage.
11/21/2014Revision: Date :M5-39Product Group 9/1/1998278Page
![Page 281: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/281.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-280A A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and themeter will indicate low voltage.
11/21/2014Revision: Date :M5-40Product Group 1/7/1999279Page
![Page 282: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/282.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-29A
M5-48A
M5-63A
M5-151A
B
B
B
B
12
24
24
12
15.0
29.2
29.2
15.0
VOLTFLD SET POINTPART NO.
M5-152A
M5-182A
M5-242(A)
M5-248A
B
B
B
B
12
24
12
24
14.2
29.2
14.2
28.4
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-41Product Group280Page
![Page 283: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/283.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-151SA6
M5-151SA8
M5-151SA12
M5-151SA24
B
B
B
B
6
8
12
24
7.8
9.6
14.2
27.5
VOLTFLD SET POINTPART NO.
M5-151SA32 B 32 37.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove the white test lead from the yellow wire of the regulator marked "stator". Field lamp should turn off andthe meter will indicate low voltage. On models with indicator light connection, removal of stator lead formregulator should cause the light to turn on and meter indicates low voltage.
NOTE * Not used for 24V and 32V
11/21/2014Revision: Date :M5-42Product Group281Page
![Page 284: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/284.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-26A
M5-27A
M5-92A
M5-93A
B
B
B
B
12
24
12
24
15.2
29.2
15.2
29.2
VOLTFLD SET POINTPART NO.
M5-153A
M5-183A
B
B
12
24
15.0
29.2
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-43Product Group282Page
![Page 285: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/285.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-104A
M5-121A
M5-179A
A
A
A
12
12
24
14.2
14.2
28.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
NOTE:The above are "SCR" type regulators. They cannot be tested on Transpo's regulator tester due to a requirementof an adapter. To test them simply install them in the appropriate alternator and check for regulation.
11/21/2014Revision: Date :M5-44Product Group283Page
![Page 286: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/286.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-164A
M5-167A
B
B
24
12
28.4
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-45Product Group284Page
![Page 287: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/287.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-265
M5-266
M5-269
M5-270
A
A
A
A
12
12
24
24
14.4
14.4
28.4
28.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-46Product Group285Page
![Page 288: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/288.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-123A
M5-128A
M5-234A
A
B
B
24
32
12
28.0
38.4
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-47Product Group286Page
![Page 289: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/289.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-158A
M5-162A
M5-166A
B
B
B
24
24
24
29.2
28.4
28.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-48Product Group287Page
![Page 290: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/290.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-160A B 24 29.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
REGULATOR CONNECTION TEST LEAD FUNCTIONBLACK BLACK BATTERY NEGATIVERED RED TRIO, IGNITION, AUXGREEN YELLOW FIELDYELLOW NO CONNECTION
11/21/2014Revision: Date :M5-49Product Group288Page
![Page 291: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/291.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-165A B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-50Product Group289Page
![Page 292: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/292.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M5-508 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M-01Product Group 10/20/1997290Page
![Page 293: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/293.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M5-509 B 12 14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M-02Product Group 12/15/1999291Page
![Page 294: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/294.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M5-515 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove black test lead from terminal marked "D+". Indicator will come on.
11/21/2014Revision: Date :M-03Product Group 10/20/1997292Page
![Page 295: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/295.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M5-170A
M5-742A
B
B
12
12
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M-04Product Group293Page
![Page 296: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/296.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M5-762 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M-05Product Group294Page
![Page 297: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/297.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M5-180A
M5-241A
M5-763A
M5-764A
B
B
B
B
12
12
12
12
14.2
14.2
14.1
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M-06Product Group295Page
![Page 298: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/298.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M5-768 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "D+". Indicator light will come on.
11/21/2014Revision: Date :M-07Product Group 9/6/1997296Page
![Page 299: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/299.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M506
M508
A
A
12
12
14.1
15.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :M-08Product Group 7/29/1997297Page
![Page 300: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/300.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M507 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M-09Product Group298Page
![Page 301: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/301.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M509
M510
A
A
12
12
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M-10Product Group 11/28/1900299Page
![Page 302: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/302.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M511 A 14 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M-11Product Group300Page
![Page 303: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/303.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M512 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white lead from stator and voltage should drop to 12.0v. lamp should come on. Field circuit lamp stayson.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :M-12Product Group 4/26/1905301Page
![Page 304: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/304.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M513 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white lead from stator and voltage should drop to 12.0v and 12V lamp should come on. Field circuit lampstays on.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :M-13Product Group 4/26/1905302Page
![Page 305: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/305.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M5-036 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M-14Product Group 5/1/1997303Page
![Page 306: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/306.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIEHOFF
VOLTFLD SET POINTPART NO.
NA2-101
NA2-102
NA2-103
A
A
A
24
12
32
27.5
14.2
37.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :N-01Product Group304Page
![Page 307: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/307.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIEHOFF
VOLTFLD SET POINTPART NO.
N9013
N9015
A
A
12
24
14.3
27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from blue wire of the regulator. Field lamp should turn off and the meter will indicate lowvoltage.
11/21/2014Revision: Date :N-02Product Group 5/1/1997305Page
![Page 308: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/308.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIEHOFF
VOLTFLD SET POINTPART NO.
N9014 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from blue wire of the regulator. Field lamp should turn off and the meter will indicate lowvoltage and indicator light will turn on.
11/21/2014Revision: Date :N-03Product Group 5/1/1997306Page
![Page 309: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/309.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIEHOFF
VOLTFLD SET POINTPART NO.
NA2-111
NA2-110
A
A
24
12
28.0
14.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from the terminal marked "IGNITION". Field lamp should turn off and the meter will indicateapproximately 12V. For NA2-111. For NA2-110.
11/21/2014Revision: Date :N-10Product Group 5/1/1997307Page
![Page 310: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/310.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETON-PAL
VOLTFLD SET POINTPART NO.
MP293
MP291
A
A
14
12
28.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :PAL-01Product Group 8/22/1902308Page
![Page 311: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/311.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETON-PAL
VOLTFLD SET POINTPART NO.
MP417 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :PAL-02Product Group 9/1/1998309Page
![Page 312: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/312.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETON-PAL
VOLTFLD SET POINTPART NO.
MP419 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :PAL-03Product Group 9/1/1998310Page
![Page 313: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/313.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPRESTOLITE
VOLTFLD SET POINTPART NO.
P8-328
P8-328A
P8-379
P8-379A
B
B
B
B
12
12
12
12
14.2
14.2
15.0
15.0
VOLTFLD SET POINTPART NO.
P8-407
P8-407A
P8-406
P8-406A
B
B
B
B
12
12
12
12
15.0
15.0
15.0
15.0
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :P8-01Product Group 5/1/1997311Page
![Page 314: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/314.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPRESTOLITE
VOLTFLD SET POINTPART NO.
P8-403
P8-403A
P8-404
P8-404A
B
B
B
B
12
12
12
12
14.2
14.2
14.2
14.2
VOLTFLD SET POINTPART NO.
P8-410
P8-410A
P8-343
P8-343A
B
B
B
B
12
12
12
12
14.2
14.2
15.0
15.0
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :P8-02Product Group 5/1/1997312Page
![Page 315: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/315.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPRESTOLITE
VOLTFLD SET POINTPART NO.
P8-354
P8-354A
P8-355
P8-355A
B
B
B
B
12
12
12
12
14.2
14.2
14.2
14.2
VOLTFLD SET POINTPART NO.
P8-357
P8-357A
P8-352
P8-352A
B
B
B
B
12
12
12
12
14.2
14.2
14.2
14.2
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :P8-03Product Group 5/1/1997313Page
![Page 316: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/316.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsPRESTOLITE
VOLTFLD SET POINTPART NO.
P8-368
P8-368A
P8-405
P8-405A
B
B
B
B
12
12
12
12
15.0
15.0
14.2
14.2
VOLTFLD SET POINTPART NO.
P8-393
P8-393A
B
B
24
24
27.5
27.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :P8-04Product Group 5/1/1997314Page
![Page 317: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/317.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI100
TRI110
A
A
12
12
14.6
14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :TRI-01Product Group315Page
![Page 318: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/318.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI400R
TRI400S
TRI405
TRI406
A
A
A
A
12
12
12
12
14.5
14.5
14.4
14.4
VOLTFLD SET POINTPART NO.
TRI410
TRI420
TRI421
A
A
A
12
12
12
14.6
14.6
14.6
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
TESTER CONNECTION CHART B ... RED TEST RED (B+) S ... RED TEST LEAD (SENSE)R ... RED TEST LEAD (IG) T ... RES TEST LEAD (TRIO) F ... YELLOW TEST LEAD (FLD)L ... RED TEST LEAD (INDICATOR LIGHT) E ... BLACK TEST LEAD (GROUND)
NOTE: Regulators shown with circuit up (Epoxy side)NOTE: After repair circuit installation, refer to complete regulator assembly procedure.
REFER TO PRODUCT GROUP TRI-04, PAGE 376-A, FOR REGULATOR'S DIAGRAM
11/21/2014Revision: Date :TRI-02Product Group 6/2/1905316Page
![Page 319: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/319.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI422
TRI430
A
A
12
12
14.6
14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
TESTER CONNECTION CHART B ... RED TEST RED (B+) S ... RED TEST LEAD (SENSE)R ... RED TEST LEAD (IG) T ... RED TEST LEAD (TRIO) F ... YELLOW TEST LEAD (FLD)L ... RED TEST LEAD (INDICATOR LIGHT) E ... BLACK TEST LEAD (GROUND)
NOTE: Regulators shown with circuit up (Epoxy side)NOTE: After repair circuit installation, refer to complete regulator assembly procedure.
REFER TO PRODUCT GROUP TRI-04, PAGE 376-A, FOR REGULATOR'S DIAGRAM
11/21/2014Revision: Date :TRI-03Product Group317Page
![Page 320: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/320.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI219
TRI220
TRI221
TRI222
A
A
A
A
12
12
12
12
14.5
14.5
14.5
14.5
VOLTFLD SET POINTPART NO.
TRI224
TRI225
TRI226
TRI227
A
A
A
A
12
12
12
12
14.5
14.5
14.5
14.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.
NOTE: Regulators shown with circuit up (Epoxy side)NOTE: After repair circuit installation, refer to complete regulator assembly procedure.
REFER TO PRODUCT GROUP TRI-07, PAGE 378-A, FOR REGULATOR'S DIAGRAM
11/21/2014Revision: Date :TRI-05Product Group 4/26/1905318Page
![Page 321: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/321.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI250
TRI251
TRI252
TRI253
A
A
A
A
12
12
12
12
14.5
14.5
14.5
14.5
VOLTFLD SET POINTPART NO.
TRI254
TRI255
A
A
12
12
14.5
14.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.
NOTE: Regulators shown with circuit up (Epoxy side)NOTE: After repair circuit installation, refer to complete regulator assembly procedure.
REFER TO PRODUCT GROUP TRI-07, PAGE 378-A, FOR REGULATOR'S DIAGRAM
11/21/2014Revision: Date :TRI-06Product Group 4/26/1905319Page
![Page 322: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/322.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI10DN B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from regulator's connection marked "STA". Field lamp should turn off and the meter willindicate 12V.
11/21/2014Revision: Date :TRI-08Product Group320Page
![Page 323: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/323.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI268
TRI270
A
A
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
TESTER CONNECTION CHART NOTE: This instruction does not apply to TRI270B ... RED TEST RED (B+) I ... GREEN TEST LEAD (I.L.) T ... RED TEST LEAD (TRIO)E ... BLACK TEST LEAD (B-) F ... YELLOW TEST LEAD (FLD) A ... RED TEST LEAD (SENSE)Remove the red test lead from the wire marked "sense". The field light will still blink, the meter will indicate from15v to 16v and the indicator lamp will remain on.
NOTE: Instruction #3 Does not apply to TRI270
11/21/2014Revision: Date :TRI-09Product Group 9/16/1998321Page
![Page 324: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/324.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI247 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from wire marked "STA". Indicator light should turn on, field lamp will remain on and themeter will indicate 12V. Remove red test lead from wire marked "IG". Field lamp should turn off.Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V.
11/21/2014Revision: Date :TRI-10Product Group 4/26/1905322Page
![Page 325: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/325.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI248 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :TRI-11Product Group 9/29/1998323Page
![Page 326: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/326.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI275
TRI285
A
A
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :TRI-12Product Group 9/17/1998324Page
![Page 327: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/327.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI278 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from the wire marked as "S". Field lamp should still blink and the meter will indicateapproximately 15.5V.
11/21/2014Revision: Date :TRI-13Product Group325Page
![Page 328: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/328.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI233 A 24 27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :TRI-14Product Group326Page
![Page 329: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/329.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI267 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from the wire marked as "C" and connect a black test lead to the "C" terminal. Field lampshould still blink and the meter will indicate approximately 12.5v.
11/21/2014Revision: Date :TRI-15Product Group327Page
![Page 330: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/330.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI839
TRI273
TRI835
A
A
A
12
12
12
14.4
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Remove red test lead from terminal marked "TRIO". Field lamp should still blink, the meter will indicate the setpoint voltage and the indicator light will turn on.2. Reconnect red test to "TRIO". Connector a black test lead to terminal marked "C". Field lamp should still blinkand the meter will indicate approximately 12.5v.
11/21/2014Revision: Date :TRI-16Product Group328Page
![Page 331: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/331.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI423 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "TRIO". Field lamp should still blink and the meter will indicateapproximately 15.5v.
11/21/2014Revision: Date :TRI-17Product Group329Page
![Page 332: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/332.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI271
TRI276
TRI836
TRI837
A
A
A
A
12
12
12
12
14.5
14.4
14.4
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove the red test lead from the wire marked as "SENSE". The field light will still blink the meter will indicatefrom 15V. to 16V, and the indicator lamp will remain on.Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V.
11/21/2014Revision: Date :TRI-19Product Group 4/26/1905330Page
![Page 333: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/333.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI257 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white lead from terminal marked "stator". The indicator light will turn on and the meter will indicateapproximately 12 volts and the field lamp will remain fully on.Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.
11/21/2014Revision: Date :TRI-20Product Group 4/26/1905331Page
![Page 334: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/334.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI232 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :TRI-21Product Group 10/20/1904332Page
![Page 335: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/335.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F8512
F8512M
F8512S
B
B
B
12
12
12
14.2
14.3
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Indicator light should turn on meter will still indicate set pointvoltage. Removal of test lead from "S" and "I" terminal will result in the field lamp turning off and the meterreading 12v. On mechanical type on due to the regulator's internal circuitry. Limit this test to a short time.
11/21/2014Revision: Date :F-02Product Group333Page
![Page 336: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/336.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM284 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Field lamp will still blink, and the meter will indicateapproximately 15.5V.
11/21/2014Revision: Date :IM-25Product Group334Page
![Page 337: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/337.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN449
IN440
A
A
12
12
14.5
14.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V.
11/21/2014Revision: Date :IN-33Product Group 4/26/1905335Page
![Page 338: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/338.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE NEVILLE
VOLTFLD SET POINTPART NO.
L1666280 A 12 13.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :L-09Product Group336Page
![Page 339: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/339.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM345 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Caution - Note:• Connect DRIVER to tester “PD”• IM345 has D-P terminal functions: D=Drive, P=Phase.• D-P Type Regulators are immediately damaged if tested using procedure typical to common S-L typeregulators, where B+ Voltage would be applied to the D terminal position.
11/21/2014Revision: Date :IM-52Product Group 10/22/1907337Page
![Page 340: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/340.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH758 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Caution - Note:• IH758 has D-P terminal functions: D=Drive, P=Phase.• D-P Type Regulators are immediately damaged if tested using procedure typical to common S-L typeregulators, where B+ Voltage would be applied to the D terminal position.
11/21/2014Revision: Date :IH-41Product Group 10/22/1907338Page
![Page 341: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/341.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB392BG A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "STA". Field lamp remain fully on and the meter will indicateapproximately 12V. Reconnect the white test lead. Remove red test lead from the terminal marked "S", field lampwill turn off, the indicator light will turn on and the meter will indicate 12V.Using VRC2010: To check for over Voltage, push the “Over Voltage” switch and the “Lamp Indicator” will turn onbetween 16.0V and 17.1V.
NOTE: Connect B- (black) test lead last, already having turned on the tester "ON" switch.• 20 ampere 60 volt field transistor voltage saturation test @ 5 amps 13.50 volts = 150 to 250 milli-volts• Undervoltage Lamp Indication = 8.50 volts to 10.00 volts• Overvoltage Lamp Indication = 16.00 volts to 17.10 volts• Current Leakage = 2.0 milli-amps
11/21/2014Revision: Date :IB-28Product Group 4/26/1905339Page
![Page 342: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/342.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D3101 B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove WHITE TEST LEAD from terminal marked "STATOR", 12 volt Lamp will turn on and Field light will turnoff.
11/21/2014Revision: Date :D-36Product Group340Page
![Page 343: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/343.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH258 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IH-35Product Group341Page
![Page 344: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/344.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH769 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white lead from stator; 12 volt lamp will come on and voltage will read 12.0 volts. Field lamp will be on.
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V.
11/21/2014Revision: Date :IH-36Product Group 4/26/1905342Page
![Page 345: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/345.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM843 A 24 28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-53Product Group 9/25/2002343Page
![Page 346: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/346.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM369 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "Stator" field and lamp light comes on. Remove green test leadfrom terminal marked "Light" field and lamp light goes off.
Using VRC2010: Connect external 3 Watt Lamp from Tester Battery Positive to the Voltage Regulator lampconnection. Do not use the VRC2010 Lamp connection.
11/21/2014Revision: Date :IM-54Product Group 4/26/1905344Page
![Page 347: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/347.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM851 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked "Stator" field and lamp light comes on and voltage will indicate 12 volts.Remove green test lead from terminal marked "Lamp" and lamp light goes off. Remove red test lead from terminal marked"Ignition" and field light goes off.* Connect black lead to "C" computer terminal and field lamp will stay on and voltage will read approximately 12.7 voltsUsing VRC2010: Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.
11/21/2014Revision: Date :IM-55Product Group 4/26/1905345Page
![Page 348: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/348.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D432 B 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove the white test lead from terminal marked "STATOR". The indicator light will turn on, field lamp will stay on and meterwill indicate approximately 12V. Disconnect the test lead from "L" terminal. Regulator will turn off and the meter will indicate12V.Using VRC2010: To check for over Voltage, push the “Over Voltage” switch and the “Lamp Indicator” will turn on between16.0V and 17.1V. Push the choke drive and the “Choke Drive Indicator Lamp” will turn on, if present.
11/21/2014Revision: Date :D-24Product Group 4/26/1905346Page
![Page 349: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/349.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN219
IN221
IN222
IN224
A
A
A
A
12
12
12
12
14.5
14.5
14.5
14.5
VOLTFLD SET POINTPART NO.
IN225
IN227
IN251
IN252
A
A
A
A
12
12
12
12
14.5
14.5
14.5
14.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IN-17Product Group 4/26/1905347Page
![Page 350: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/350.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN253
IN254
IN255
IN429
A
A
A
A
12
12
12
12
14.5
14.5
14.5
14.5
VOLTFLD SET POINTPART NO.
IN431
IN435
IN254CN
IN255CN
A
A
A
A
12
12
12
12
14.5
14.5
14.5
14.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IN-18Product Group 4/26/1905348Page
![Page 351: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/351.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM757 A 12 14.70
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-56Product Group 7/24/2002349Page
![Page 352: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/352.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH744 A 12.0 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove sense lead and voltage rises to approximately 15.5 volts, reconnect sense lead. Remove white test leadfrom stator, 12 volt lamp comes on, voltage drops to 12 volts and field LED stays on (soft start).
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V.
11/21/2014Revision: Date :IH-37Product Group 4/26/1905350Page
![Page 353: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/353.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH738 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove sense lead and voltage rises to approximately 15.5 volts, reconnect sense lead. Remove white test leadfrom stator, 12 volt lamp comes on, voltage drops to 12 volts and field LED stays on (soft start).
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V.
11/21/2014Revision: Date :IH-38Product Group 4/26/1905351Page
![Page 354: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/354.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D404 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-38Product Group352Page
![Page 355: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/355.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM848 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove sense lead and voltage rises to approximately 15.4 volts, reconnect sense lead. Remove white test leadfrom stator, 12 volt lamp comes on, voltage drops to 12 volts and field LED stays on (soft start). Remove Lightlead field light and Lamp light turn off.
11/21/2014Revision: Date :IM-57Product Group353Page
![Page 356: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/356.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M519 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove “White” lead from “Stator”, meter will read 12.0 volts field light will come on and 12 volt lamp will comeon. Remove “Lamp” terminal and field light will go out and lamp light will go out.
11/21/2014Revision: Date :M-15Product Group 7/28/1904354Page
![Page 357: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/357.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH774 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white lead from stator, field circuit lamp will stay on. 12V lamp will come on and voltage will drop to 12V.
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V.
11/21/2014Revision: Date :IH-39Product Group 4/26/1905355Page
![Page 358: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/358.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH742 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove sense lead and voltage rises to approximately 15.5 volts, reconnect sense lead. Remove white test leadfrom stator, voltage remains the same and lamp comes on.
Using VRC2010:To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V.
11/21/2014Revision: Date :IH-40Product Group 4/26/1905356Page
![Page 359: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/359.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM350 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove sense lead and voltage rises to approximately 15.4 volts, reconnect sense lead. Remove white test leadfrom stator, 12 volt lamp comes on, voltage drops to 12 volts and field LED stays on (soft start).
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V.
11/21/2014Revision: Date :IM-58Product Group 4/26/1905357Page
![Page 360: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/360.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM341 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove sense lead and voltage rises to approximately 15.4 volts, reconnect sense lead. Connect C terminal ofregulator to C terminal on tester, and press Computer button, Voltage drops to 13.1 volts. Remove white test leadfrom stator, 12 volt lamp comes on, voltage drops to 12 volts and field LED stays on (soft start). Remove Lightlead field light and Lamp light turn off.
11/21/2014Revision: Date :IM-59Product Group 9/28/1904358Page
![Page 361: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/361.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN215
IN452
A
A
12
12
14.6
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect C terminal of regulator to C terminal on tester, and press Computer button, Voltage will read 12.6V.Remove white test lead to confirm charge indicator light function.To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0Vand 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.IN452 - No connection on black test lead labeled “C” on IN215, “D” on IN452.
11/21/2014Revision: Date :IN-38Product Group 12/29/1906359Page
![Page 362: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/362.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM358 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
No additional test required.
11/21/2014Revision: Date :IM-60Product Group 5/2/1905360Page
![Page 363: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/363.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D751 A 12 15.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
IMPORTANT ... Tester FIELD LOAD Switch Must Be Set to 0.5 AMP !
Remove "White" test lead from terminal marked "Stator". The indicator light will turn on, field lamp will stay on andthe meter will indicate approximately 12 volts. Remove red test lead from Sense and light will come on. Remove"Green" test lead, lamp will go off and field lamp will go off.
IMPORTANT ... Tester FIELD LOAD Switch Must Be Set to 0.5 AMP !
11/21/2014Revision: Date :D-40Product Group 4/7/2008361Page
![Page 364: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/364.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM853 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove white test lead from terminal marked “Stator” field, lamp light comes on and Voltage will incate 12 Volts.Remove green test lead from terminal marked “Lamp” and lamp light goes off. Remove red test lead fromterminal marked “Ignition” and the field light goes off.
11/21/2014Revision: Date :IM-61Product Group 5/3/1905362Page
![Page 365: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/365.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D10SE132
D10SE138
A
A
12
12
14.8
14.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-39Product Group 5/3/1905363Page
![Page 366: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/366.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMANDO
VOLTFLD SET POINTPART NO.
IY903 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from "S" terminal. Voltage will go up to approximately 15.5V.
11/21/2014Revision: Date :IY-05Product Group 5/3/1905364Page
![Page 367: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/367.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM465 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• IM465 has D-P terminal functions: D=Drive, P=Phase.• D-P Type Regulators are immediately damaged if tested using procedure typical to common S-L typeregulators, where B+ Voltage would be applied to the D terminal position.
• IM465 field brush is top / outer brush; (unlike many other Mitsubishi regulators).
11/21/2014Revision: Date :IM-62Product Group 10/22/1907365Page
![Page 368: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/368.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F797
F797HD
A
A
12
12
*14.0
*14.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect RC terminal of regulator to RCV regulator on tester. Connect LI terminal of regulator to LI terminal on tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.* The 14.0V Set Point indicated above is the 'default VSet' (no vehicle PCM input).
11/21/2014Revision: Date :F-13Product Group 11/4/1905366Page
![Page 369: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/369.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F601
F601HD
A
A
12
12
14.0*
14.0*
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.* The 14.0V Set Point indicate above is the 'default VSet' (no vehicle PCM input).
• AS-RC-LI Terminals• Regulation Voltage Controlled by Vehicle PCM
11/21/2014Revision: Date :F-12Product Group 11/4/1905367Page
![Page 370: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/370.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI-MARELLI
VOLTFLD SET POINTPART NO.
IX131
IX131HD
A
A
12
12
*14.0
*14.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect RC terminal of regulator to RCV terminal on tester. Connect LI terminal of regulator to LI terminal on tester1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.* The 14.0V Set Point indicated above is the 'default VSet' (no vehicle PCM input).
11/21/2014Revision: Date :IX-08Product Group 4/7/2008368Page
![Page 371: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/371.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-251 A 24 26.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
DO NOT CONNECT BOTH SENSE LEADS AT THE SAME TIME.
• VSET1: Disconnect Sense (Purple Lead Wire) ... Voltage Regulation 28.00V +/- 0.5V
• VSET2: Connect Regulator as shown; Use Resistor 5K Ohm... Voltage Regulation 26.5V +/- 0.5V
NOTE: THE VOLTAGE IS BELOW METER RANGE WITHOUT USING A RESISTOR ON YELLOW WIRE.REGULATOR IS FACTORY SET AT 26.5V. WE DO NOT RECOMMEND TURNING VARIABLERESISTOR UNTIL INSTALLED ON VEHICLE.
11/21/2014Revision: Date :M5-51Product Group 11/8/1905369Page
![Page 372: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/372.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI845 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect Computer (C) to Black (B-), voltage will read 12.5 voltsRemove Sense (Red), Lamp light will turn on.
* Connect only for Computer (C) function test
11/21/2014Revision: Date :TRI-22Product Group 11/21/1905370Page
![Page 373: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/373.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM846 A 24 28.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IM-63Product Group 1/25/1906371Page
![Page 374: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/374.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M517 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove “White” lead from “Stator”, meter will read 12.0 volts field light will come on and 12 volt lamp will comeon. Remove “Lamp” terminal and field light will go out and lamp light will go out.
11/21/2014Revision: Date :M-16Product Group 2/9/1906372Page
![Page 375: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/375.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB251 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Power On: Field light should blink and meter will indicate approximately the set point voltage indicated in the above table.Remove white test lead from terminal marked "Stator" field light and "Lamp" light will come on and voltage will show 12 volts.Reconnect "Stator" wire;Remove green test lead from "Light" terminal, field light will continue to blink and meter will indicateapproximately the set point voltage indicated in the above table. Reconnect "Lamp" wire;Remove ignition, field light willcontinue to blink, "Lamp" light will turn on and meter will indicate approximately the set point voltage indicated in the abovetable.
11/21/2014Revision: Date :IB-29Product Group 3/13/2006373Page
![Page 376: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/376.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
DE604
DE605
DE609
A
A
A
12
12
12
14.8
14.8
14.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-05Product Group374Page
![Page 377: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/377.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
DE708 B 12 14.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove "White" test lead from "Stator" lamp will come on and voltage will go to 12 volts.Reconnect "White" test Lead.Remove "Green" Lead from "Light" terminal regulator will go to 12 volts and "Field" light will stop blinking.
11/21/2014Revision: Date :D-41Product Group 7/26/1906375Page
![Page 378: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/378.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB229 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove White Test lead from Stator Terminal, Lamp will come on, display will show 12 volts and field light willstay on. Remove Green Test lead and field light will turn off.
11/21/2014Revision: Date :IB-30Product Group 8/11/2006376Page
![Page 379: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/379.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB235 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove White Test Lead from Stator, Lamp Light comes on and Field Light stay on.Remove Green Test Lead from Light terminal, Lamp Light and Field Light turn off.
The voltage will drop when remove the stator lead.
11/21/2014Revision: Date :IB-31Product Group 8/25/2006377Page
![Page 380: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/380.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-61A
M5-74A
M5-79A
M5-94A
B
B
B
B
24
32
12
32
28.0
39.2
14.2
38.4
VOLTFLD SET POINTPART NO.
M5-136A
M5-147A
M5-148A
M5-154A
B
B
B
B
12
12
24
12
14.2
15.00
28.0
14.2
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M5-01Product Group378Page
![Page 381: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/381.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB298 B 24 28.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove White test Lead from Stator Light comes on. Reconnect Stator.Remove Green test Lead from Lamp, voltage remains same. Reconnect Light.Remove White test Lead from Stator, Light and Ignition voltage goes to 24 volts.
• Note: IB298 without Loss of Sense Lamp Indication• W-L-15-S-DFM Terminals • OE Compliant Circuit Protection & Functions... 'With Stator Start,
11/21/2014Revision: Date :IB-32Product Group 11/6/2006379Page
![Page 382: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/382.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsSAWAFUJI
VOLTFLD SET POINTPART NO.
IW700
IW701
A
A
24
12
28.5
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove test lead from Stator terminal and light will come on; reconnect test lead to Stator terminal. Remove testlead from Ignition terminal, field light will stop flashing and voltage goes to default. (see note)
Note: Remove test lead from Ignition terminal, field light will stop flashing and voltage goes to 12V for (IW701)and 24V (IW700).
11/21/2014Revision: Date :IW-01Product Group 10/29/1907380Page
![Page 383: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/383.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO / MOTOROLA
VOLTFLD SET POINTPART NO.
M515 B 12 14.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :M-17Product Group381Page
![Page 384: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/384.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM529 A 12 *14.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Use VRC2010 tester to complete RC voltage setpoint testing, Connect RC terminal to VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.* The 14.0V Set Point indicate above is the 'default VSet' (no vehicle PCM input).
11/21/2014Revision: Date :IM-64Product Group382Page
![Page 385: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/385.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D3587 B 12 13.8*
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect RVC terminal of D3587 to RCV terminal on tester. Connect FR terminal of D3587 to LI terminal ontester.2. Adjust Comm Voltage switch to position 13, Setpoint is 11.8V.3. Adjust Comm Voltage switch to position 14, Setpoint is 13.3V.4. Adjust Comm Voltage switch to position 15, Setpoint is 14.7V.
• This is GM RCV type, ‘Regulated Voltage Control’ system regulator.• Regulated Voltage Control is provided by the vehicle’s PCM / ECU or GBCM (Generator Battery ControlModule) via a digital ‘PWM’ signal applied to the regulator L-terminal.
11/21/2014Revision: Date :Product Group383Page
![Page 386: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/386.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN369 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
The FR terminal is not connected.Disconnect the Sense terminal, the light should be ON, and the set point will read approximately 14.5 volts.Push the Over Voltage button, the set point should read approximately 17.3 volts.
11/21/2014Revision: Date :Product Group384Page
![Page 387: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/387.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN317 A 12 14.35
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
No connection to the FM Out terminal.Push Over Voltage button, Light should turn ON, set point is approximately 17.2 volts.Push Choke button, Choke Light should turn ON.
11/21/2014Revision: Date :Product Group385Page
![Page 388: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/388.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM545 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Disconnect the Stator terminal and the Light should turn ON.Reconnect the Stator terminal, push the Over Voltage button, the light should turn ON, the set point will beapproximately 17.2 volts.
11/21/2014Revision: Date :Product Group386Page
![Page 389: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/389.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO MOTOROLA
VOLTFLD SET POINTPART NO.
M526 B 12 14.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
After applying power part requires about 10 seconds to start regulating.Must install a 1.5uF capacitor betweenStator terminal #2 and B-. Attach VRC2010 Stator lead to Stator terminal #1.Disconnect Sense lead and light turns ON.Push Choke button, choke light will turn ON.Reconnect Sense lead and push Over Voltage button, light should turn ON, set point is approximately 17.3 volts.
11/21/2014Revision: Date :Product Group387Page
![Page 390: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/390.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB206 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect FR terminal.Push Choke button and Choke light should be ON.
11/21/2014Revision: Date :Product Group388Page
![Page 391: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/391.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM476 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect Sense lead and Light should turn ON. Set Point will be approximately 15.6 volts.Reconnect the Sense lead and press the Over Voltage button. The light should be ON, and the set point will beapproximately 17.3 volts.
11/21/2014Revision: Date :Product Group389Page
![Page 392: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/392.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN258 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• When Ignition wire is disconnected from the regulator, VSet reading drops to default 12V.• When both the Field and Stator connections are disconnected from regulator, lamp illuminates.
Note: This regulator’s light circuit functions when a combined condition exists ... Loss of the Stator signal and B+Voltage drops below 14.0V (approx).
• IN258 is an "A" circuit, low side drive regulator.• D-IG-L Terminals (D = dummy / no function)• VSet 14.4V (+/- 0.2V).• Field rating 5-Amps.• Ignition activated.
11/21/2014Revision: Date :Product Group390Page
![Page 393: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/393.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
in257 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove test lead from the terminal marked "*". The indicator light will turn on and the meter will indicateapproximately 12V and the field lamp will remain fully on (this is the soft start mode of the regulator).Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn onbetween 16.0V and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.
NOTE on Stator: Transpo (White test lead) / OE (Red test lead)REFER TO PRODUCT GROUP IN-29, PAGE 341-A FOR REGULATOR'S DIAGRAM
11/21/2014Revision: Date :Product Group391Page
![Page 394: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/394.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB558 B 24 25.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Power On: Note Set Point on VRC2010 digital display;Disconnect Sense terminal and note set point readingshould rise to approximately 28.5 volts.
11/21/2014Revision: Date :Product Group392Page
![Page 395: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/395.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6002 B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• Set Field Load Switch to 0.5 Amp only.• Disconnect the Sense Lead and verify Light Turns On.• No over voltage lamp
• S-IG-L Terminals• Ignition Activated• Without LRC• Standard Lamp – No Output
11/21/2014Revision: Date :Product Group393Page
![Page 396: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/396.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6001 B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• Set Field Load Switch to 0.5 Amp only.• Disconnect the Sense Lead and verify Light Turns On.
• S-IG-L Terminals• Ignition Activated.• Without LRC• Active Lamp – With Output
11/21/2014Revision: Date :Product Group394Page
![Page 397: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/397.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6301
IN6301CN
B
B
12
12
14.1
14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• Set Field Load Switch to 0.5 Amp only.
• IG-S-L-M(FR) Terminals• Ignition Activated• LRC 6-Seconds, Full Range• Multi-Step TempCo• Standard Lamp – No Output
11/21/2014Revision: Date :Product Group395Page
![Page 398: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/398.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6335 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• Set Field Load Switch to 0.5 Amp only• Connect the C Terminal to B-, the set point should drop to 12.7 Volts• Remove Stator wire and the Light should turn ON
• IG-C-L-FR Terminals• Ignition Activated• LRC 11-Seconds (to 400HZ)• Standard Lamp – No Output• Due to the long delay, automatic spin bench testers should be setup to be in the ‘Wait Always’ mode. Not doingso may result in an inaccurate performance reading.
11/21/2014Revision: Date :Product Group396Page
![Page 399: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/399.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI-MARELLI
VOLTFLD SET POINTPART NO.
IX110CN A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group397Page
![Page 400: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/400.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M3118C
M3118
A
A
24
24
28.5
28.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group398Page
![Page 401: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/401.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB236 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove White Test Lead from Stator, Lamp Light comes on and Field Light stay on.Remove Green Test Lead from Light terminal, Lamp Light and Field Light turn off.
•IG-S-L-DFM Terminals • With LRC 5-Seconds • External Sense(EXTS) • Ignition Activated but will Lamp Activateand Stator Start • Active Lamp Function -With Output • Field, Lamp, Choke Short Circuit Protection
11/21/2014Revision: Date :IB-Product Group 3/6/2009399Page
![Page 402: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/402.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6004 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• Set Field Load Switch to 0.5 Amp only* Connect C terminal to B-, verify Set-Point is 12.8 V +/- 0.2V
• IG-C-L-FR Terminals• Standard Lamp Function - No Output• No Output LRC
11/21/2014Revision: Date :Product Group400Page
![Page 403: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/403.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6302 B 12 14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1.Set Field Load Switch to 0.5 Amp only.2.This regulator is not tested for Over Voltage Lamp or Loss of Sense3.The RLO Function is similar to the RC control function found in PCM controlled Ford 6G systems and GM RVCsystems.When the vehicl ECM takes command of the regulator’s RLO circuit,the alternator Voltage follows the PWM signalduty cycle;the regulation Voltage will range between 11.80V and 14.99V as needed
• IG-RLO-L-M Terminals• Ignition Activated• LRC 6-Seconds, Full Range• Multi-Step TempCo (unless in RLO mode)
11/21/2014Revision: Date :Product Group401Page
![Page 404: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/404.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D4476 B 24 28.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect Sense Lead, verify the setpoint is 28.0+/-0.2v, also verify the the Light is on.Disconnect Stator Lead, verify the Light is on and the part stops function.Push the OVER VOLTAGE button and verify the Light is on.
D4476 is Stator Activated.Load AMP switch is 0.5 position only.
11/21/2014Revision: Date :Product Group402Page
![Page 405: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/405.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D4152 B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect Sense Lead and verify the setpoint is 14.2+/-0.2v.Disconnect Stator Lead and verify the Light is on.Push the OVER VOLTAGE button and verify the Light is on.
D4152 is Stator Activated.Load AMP switch is 0.5 position only.
11/21/2014Revision: Date :Product Group403Page
![Page 406: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/406.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB520 A 12 14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect Stator Lead and verify the Light is on.Push the CHOKE DRIVE button and verify the CHOKE DRIVE lamp is on.
IB520 is Stator Activated.Load AMP switch is 0.5 position only.
11/21/2014Revision: Date :Product Group404Page
![Page 407: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/407.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMANDO
VOLTFLD SET POINTPART NO.
IY028 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group405Page
![Page 408: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/408.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM854 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnecting Sense turns light on.
11/21/2014Revision: Date :Product Group406Page
![Page 409: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/409.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D840 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the part stops regulating and the voltage goes down to 12.0v.
11/21/2014Revision: Date :Product Group407Page
![Page 410: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/410.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6322 B 12 14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• Set Field Load Switch to 0.5 Amp only.• No Over Voltage Lamp• No RLO terminal test default voltage test only
• IG-RLO-L-M Terminals• Ignition Activated• LRC 6-Seconds, Full Range• Multi-Step TempCo (unless in RLO mode)
11/21/2014Revision: Date :Product Group408Page
![Page 411: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/411.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6304 B 12 14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• Set Field Load Switch to 0.5 Amp only.• Disconnect the Sense Lead and verify Light Turns On (slight delay), reconnect Sense Lead.• Disconnect Ignition Lead, voltage goes to 12 volts, Field Light turns off and Lamp Light turns off.
• IG-S-L-M(FR) Terminals• Ignition Activated• LRC 6-Seconds, Full Range• Multi-Step TempCo• Standard Lamp – No Output
11/21/2014Revision: Date :Product Group409Page
![Page 412: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/412.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6003 B 12 15.0V
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• Set Field Load Switch to 0.5 Amp only• Disconnect the Sense Lead and verify Light Turns On with Delay• This Regulator without Over Voltage Lamp Indication
• S-F-L Terminals• Stator Activated.• LRC 9-Seconds (to 400HZ)• Standard Lamp – No Output
11/21/2014Revision: Date :Product Group410Page
![Page 413: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/413.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6009 B 12 14.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• Set Load Amperage Switch to 0.5 Position Only• No over voltage lamp• Regulator without Over Voltage Lamp Indication
• F-L Terminals• Lamp Activated.• LRC 2-Seconds (to 400HZ)• Standard Lamp Function – No Output
11/21/2014Revision: Date :Product Group411Page
![Page 414: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/414.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6304 B 12 14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• Set Field Load Switch to 0.5 Amp only.• Disconnect the Sense Lead and verify Light Turns On
... Need to verify all !!!!
• IG-S-L-M(FR) Terminals• Ignition Activated• LRC 6-Seconds, Full Range• Multi-Step TempCo• Standard Lamp – No Output
11/21/2014Revision: Date :Product Group412Page
![Page 415: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/415.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB314
IB696
B
B
12
12
13.8*
13.8*
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 11.8V.2. Adjust Comm Voltage switch to position 14, Setpoint is 13.3V.3. Adjust Comm Voltage switch to position 15, Setpoint is 14.4V.Note: The Voltages listed above are approximate and may not exactly match your meter read out.
• This is an RVC type, ‘Regulated Voltage Control’ system regulator.• Regulated Voltage Control is provided by the vehicle’s PCM / ECU or GBCM (Generator Battery ControlModule) via a digital ‘PWM’ signal applied to the regulator L-terminal.
11/21/2014Revision: Date :Product Group413Page
![Page 416: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/416.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB231 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
VRC2010 Tests:• To check for presence of Active Lamp function - Press ‘Choke Drive’ button, choke lamp will illuminate• To check for presence of Over Voltage function - Press ‘Over Voltage’ button, indicator lamp will illuminate
IB231• With LRC and Soft Start• L (D+) Terminal M5
11/21/2014Revision: Date :IB-Product Group 11/2/2003414Page
![Page 417: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/417.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
D907 B 12 14.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect Stator Lead and verify the Light is on.
B-Circuit, Volt Set 14.0V• S-F-L-P Terminals• Stator Activated• Full Short Circuit Protection• Excellent Choice for 1-Wire System
11/21/2014Revision: Date :Product Group415Page
![Page 418: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/418.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO MOTOROLA
VOLTFLD SET POINTPART NO.
M523 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ
• Terminal Designation 16E-15 (Lamp-Ignition) • Stator Activated • LRC 5-Seconds • OE Compliant SoftStart • Lamp-Choke, Field Short Circuit Protection
11/21/2014Revision: Date :Product Group416Page
![Page 419: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/419.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB286 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• To check for presence of Active Lamp function - Press ‘Choke Drive’ button, choke lamp will illuminate
• L-DFM Terminals • LRC 2.5 Seconds, w/ Soft Start • Active Lamp Function – With OutputNOTE: VRC101-34 adapter shown for enhance stator signal, not all late model regulators need enhance signal
11/21/2014Revision: Date :IB-Product Group 11/2/2003417Page
![Page 420: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/420.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB261
IB261S-B40
B
B
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.• Push the Choke switch and the "Choke Drive" will turn on.• Remove white test lead from terminal marked "Stator" - the Lamp will come on and
Voltage will show 12 volts.• Remove green test lead from "light" terminal, field light will go out and voltage stays at 12 volts.
• L-FR Terminals • Stator Activated• With Soft Start & LRC• TC -10mV/C• Active Lamp Circuit -With Output
11/21/2014Revision: Date :IB-26Product Group 11/2/2003418Page
![Page 421: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/421.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB201 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1 Remove white test lead from terminal marked "Stator" - the Field light and Lamp will come on andVoltage will show 12 volts.
2 Remove green test lead from "light" terminal , field light will go out and voltage stays at 12 volts.3 No Over Voltage and Lamp.4 Push choke drive button and choke drive lamp should be on.
• VSet 14.4 +/- 0.2• L-DFM Terminals• 2.5 Second LRC• Active Lamp Circuit - With Output• Ref. F-00M-225-401, 0-122-1AA-5BO, 0-122-9AA-0X0
11/21/2014Revision: Date :IB-26Product Group 11/2/2003419Page
![Page 422: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/422.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO MOTOROLA
VOLTFLD SET POINTPART NO.
M520 B 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ
11/21/2014Revision: Date :Product Group420Page
![Page 423: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/423.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO MOTOROLA
VOLTFLD SET POINTPART NO.
M524 B 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ
• F-L terminals• Lamp Activated• With FR Resistor
11/21/2014Revision: Date :Product Group421Page
![Page 424: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/424.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO MOTOROLA
VOLTFLD SET POINTPART NO.
M536 B 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ
11/21/2014Revision: Date :Product Group422Page
![Page 425: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/425.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB252 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove White test Lead from Stator Light comes on. Reconnect Stator.Remove Red test Lead from Sense, Light comes on. Reconnect Sense.Remove Green test Lead from Lamp, voltage remains same. Reconnect Light.Remove White test Lead from Stator, Light and Ignition voltage goes to 12 volts.
• L-Terminal M5• Active Lamp Function - With Output• Lamp, Field, Choke Drive Short Circuit Protection
11/21/2014Revision: Date :IB-32Product Group 11/6/2006423Page
![Page 426: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/426.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO MOTOROLA
VOLTFLD SET POINTPART NO.
M528 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ
Stator Activated • OE Compliant Soft Start • Under Voltage Lamp • Field, Lamp, Choke - Short CircuitProtection
11/21/2014Revision: Date :Product Group424Page
![Page 427: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/427.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB226 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group425Page
![Page 428: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/428.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB297 B 24 28.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect FR to tester “LI”, Grey.
Remove White test Lead from Stator Light comes on. Reconnect Stator.Remove Red test Lead from Sense, Light comes on. Reconnect Sense.Remove Green test Lead from Lamp, voltage remains same. Reconnect Light.Remove White test Lead from Stator, Light and Ignition voltage goes to 12 volts.• W-L-15-S-DFM Terminals • OE Compliant Circuit Protection & Functions... 'With Stator Start,
11/21/2014Revision: Date :Product Group426Page
![Page 429: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/429.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F610 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
To Check for presence of over voltage function-Press “over-voltage button”
• S-D-L Terminals (Sense-N/C-Light)• M3 Field Post• F610 noted to replace OE regulators having a white insert surrounding the heat sink.
11/21/2014Revision: Date :F-12Product Group 11/4/1905427Page
![Page 430: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/430.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F613 A 12 14.45
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
To check presence of over voltage function- Press O.V. button
• AS-FR-IL Terminals• Soft Start• Over-Voltage Lamp Function• F613 noted to replace OE regulators having a green insert surrounding the heat sink.
11/21/2014Revision: Date :F-12Product Group 11/4/1905428Page
![Page 431: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/431.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH768 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked "S". Filed lamp should still blink and the meter will indicateapproximately 15.5 volts.
11/21/2014Revision: Date :Product Group429Page
![Page 432: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/432.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN460 A 24 28.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
• Remove white lead from stator connection and note the following:... Indicator lamp should light and voltage stay the same
• Using VRC2010 to check for ‘Over Voltage’:... Push the ‘Field Diode’ switch and the ‘Field Diode Lamp’ will turn on.
• Ignition (IGN) activated.• Stator input turns off the Light.• Standard Lamp Circuit - No Output• Field Rating 3-Amps.• Typical Vsat 1.20-Volts, @ 3-Amps, 24-Volts.
11/21/2014Revision: Date :Product Group430Page
![Page 433: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/433.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6324 B 12 13.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 11.8V.2. Adjust Comm Voltage switch to position 14, Setpoint is 13.3V.3. Adjust Comm Voltage switch to position 15, Setpoint is 14.4V.* The 13.8V Set Point indicate above is the 'default VSet' (no vehicle PCM input).
Stator or RVC Activated.
11/21/2014Revision: Date :Product Group431Page
![Page 434: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/434.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-313 A 12V 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
disconnect Sense, check the secondary voltage, it is 15.4+/-0.2V.
Light Activated.
11/21/2014Revision: Date :Product Group432Page
![Page 435: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/435.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN447HD A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect stator, the light is ON and the regulator is function.2. Push the Over Voltage Button on the pannel, the light will be ON.3. Push the Field Diode Button on the pannel, the field diode LED will be ON.
Ignition Activated.
11/21/2014Revision: Date :Product Group433Page
![Page 436: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/436.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN453HD A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect stator, the field light is ON and the regulator goes to 12V. Reconnect stator.2. Disconnect Sense, the setpoint is 14.5+/-0.2V and light comes on. Reconnect Sense.3. Push the Over Voltage Button on the pannel, the light will be ON.4. Push the Field Diode Button on the pannel, the field diode LED will be ON.
Ignition Activated. Remove Ignition, voltage goes to 12V and light is off.
11/21/2014Revision: Date :Product Group434Page
![Page 437: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/437.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM342 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect SENSE, the set point is 15.6+/-0.2V.2. Disconnect Stator, the lamp light comes on, field light stays on and volts go to 12 volts..3. Disconnect Light, the part stops regulation.4. Push the Field Diode Button on the panel, the Field Diode LED is on.
Light Activated.
11/21/2014Revision: Date :Product Group435Page
![Page 438: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/438.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsCS130D
VOLTFLD SET POINTPART NO.
D9715 B 12 14.70
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1.POWER OFF: Set “Voltage Range” and “FLD” switches to desire settings; Connect the voltage regulatoras indicated in the diagram below, except for the “Computer” terminals.
2.POWER ON: Field lamp should blink and meter will indicate approximately the set point voltageindicated in the above table.
3.Connect black test lead to “Computer” terminal voltage goes to approx. 13.2 volts, Disconnect black test lead from“Computer” terminal. Disconnect “Stator” terminal, light comes on and voltage reads 12.0 volt and field light stays on.
11/21/2014Revision: Date :D-34Product Group436Page
![Page 439: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/439.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN3054 B 12 14.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the field lamp should blink, check the reading on the meter, it should be 13.9+/-0.2v.2. Disconnect Stator, the light should be ON, and voltage reads 12.0 volt and field light stays on.3. Disconnect Ignition, the part should stop regulation.4. Push the Field Diode Button on the panel, the Field Diode lamp should be on.
Ignition Activated.
11/21/2014Revision: Date :Product Group437Page
![Page 440: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/440.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN302 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove red test lead from terminal marked “S”, lamp turns on and voltage remains the same. Reconnect.Remove white test lead from terminal marked stator, lamp light turns on an voltage goes to 12 volts with field lighton.
11/21/2014Revision: Date :Product Group438Page
![Page 441: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/441.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-313CN A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the set point should be 15.4+/-0.2V.
Light Activated.
11/21/2014Revision: Date :Product Group439Page
![Page 442: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/442.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6315 B 12 14.35
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Connect C terminal to the B- of VRC2010, the set point should be 12.7+/-0.2V.2. Remove C, disconnect Stator, the Light should be on, the regulator continues regulating.3. Connect Stator, disconnect Ignition, the regulator stops regulating.
Ignition Activated.
11/21/2014Revision: Date :Product Group440Page
![Page 443: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/443.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN9252 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
D+ Activated/Excited.
11/21/2014Revision: Date :Product Group441Page
![Page 444: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/444.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D2198 A 12 14.35
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group442Page
![Page 445: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/445.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH701
IH701V
A
A
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect Stator, the light should comes on.
Light Activated
11/21/2014Revision: Date :Product Group443Page
![Page 446: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/446.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
TRI744 A 12 14,4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the set point should be 15.3+/-0.2v.2. Reconnect Sense, remove Stator, the Lamp comes on and the voltage goes to 12.0V.3. Reconnect Stator and push the ‘Over Voltage’ button on the panel, the Lamp comes on.
Stator Activated
11/21/2014Revision: Date :Product Group444Page
![Page 447: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/447.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM498 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp comes on.2. Reconnect Stator, push the ‘Choke Drive’ button on the panel, the Lamp comes on.
Light Activated.
11/21/2014Revision: Date :Product Group445Page
![Page 448: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/448.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsTE REPAIR CIRCUIT
VOLTFLD SET POINTPART NO.
TRI341 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the set point should be 15.5+/-0.2v.2. Reconnect Sense, remove Stator, the Lamp comes on and the voltage goes to 12.0V.3. Reconnect Stator and push the ‘Over Voltage’ button on the panel, the Lamp comes on.
*Connect Black Test Lead to terminal marked “C”, voltage will drop to approximately 12.5v.
11/21/2014Revision: Date :Product Group446Page
![Page 449: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/449.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB248 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove White Test lead from Stator Terminal, Lamp will come on, display will show 12 volts and field light willstay on. Remove Green Test lead and field light will turn off.
11/21/2014Revision: Date :Product Group447Page
![Page 450: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/450.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM480 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect SENSE, the set point should be 15.6 +/- 0.2V, and the Light comes on.2. Reconnect SENSE, disconnect STATOR, the Light comes on.
Light Activated.
11/21/2014Revision: Date :Product Group448Page
![Page 451: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/451.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6343 B 12 13.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect Sense, the setpoint should be 13.85+/-0.2V, then reconnect.Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.* The 13.5V Set Point indicate above is the 'default VSet' (no vehicle PCM input).
RC or STATOR activated
11/21/2014Revision: Date :Product Group449Page
![Page 452: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/452.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IN6349 B 12 13.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect Sense, the setpoint should be 13.85+/-0.2V, then reconnect.Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.* The 13.5V Set Point indicate above is the 'default VSet' (no vehicle PCM input).
RC or STATOR activated
11/21/2014Revision: Date :Product Group450Page
![Page 453: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/453.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
DE1650 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Push the Over Voltage button on the panel, the Lamp Light comes on.2. Push the Choke Drive button on the panel, the Choke Light comes on.
Stator Activated.
11/21/2014Revision: Date :Product Group451Page
![Page 454: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/454.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN248 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Push the Choke Drive button on the panel, the Choke light comes on.
Ignition Activated
11/21/2014Revision: Date :Product Group452Page
![Page 455: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/455.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO 5si
VOLTFLD SET POINTPART NO.
D850
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group453Page
![Page 456: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/456.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMANDO
VOLTFLD SET POINTPART NO.
IY146 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect SENSE, the setpoint should be 15.3+/-0.2V,2, Reconnect SENSE, then connect C terminal to the B-, the setpoint should be 12.7+0.2v/-0.3v.
Light Activated.
11/21/2014Revision: Date :Product Group454Page
![Page 457: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/457.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN330 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Ignition Activated.
11/21/2014Revision: Date :Product Group455Page
![Page 458: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/458.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D1332 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the set point should be 14.5 +/-0.2V.2. Reconnect Sense and disconnect Stator, the Light Lamp comes on, and the Field Lamp dims.3. Reconnect Stator, push the Over Voltage button on the panel, the Light Lamp comes on.4. Push the Choke Drive button on the panel, the Choke Lamp comes on.
• Stator Activated• Over Voltage Lamp• Under Voltage Lamp• Field, Lamp short circuit protection• Active Lamp – With Output
11/21/2014Revision: Date :Product Group456Page
![Page 459: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/459.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB5369 B 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Push the Choke Drive button on the panel, the Choke Light comes on.2. Disconnect Stator, the Lamp Light comes on, the Field Lamp is dim.
Stator Activated
11/21/2014Revision: Date :Product Group457Page
![Page 460: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/460.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6015 B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should be 13.9+/-0.2V and the Lamp Light comes on.2. Reconnect Sense, and disconnect Stator, the Lamp Light comes on, and the field Light is dim.
Ignition Activated.
11/21/2014Revision: Date :Product Group458Page
![Page 461: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/461.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN9254 A 24 27.9
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
D+ Activated/Excited.
11/21/2014Revision: Date :Product Group459Page
![Page 462: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/462.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB200 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator comes on and the Field Circuit LED should be dim.2. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.3. Push the Choke Drive button on the panel, the Choke Drive Indicator comes on.
• VSet 14.4 +/- 0.2• 15-61E Terminals (15=IGN, 61E=IL/Lamp)• With Soft Start & LRC• Ignition, Lamp, or Stator Activated• Active Lamp – With Output
11/21/2014Revision: Date :Product Group460Page
![Page 463: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/463.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN209
IN210
A
A
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IN-01Product Group 3/26/1998461Page
![Page 464: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/464.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB390 A A 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :IB-24Product Group 11/28/1900462Page
![Page 465: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/465.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D2295 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the set point should be 15.55+/-0.2V.
Light or Ignition Activated.
11/21/2014Revision: Date :Product Group463Page
![Page 466: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/466.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
TRI851HD A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not conncet FR and C.1. Disconnect Stator, the Lamp Indicator comes on and the Field Circuit LED should be dim.2. Reconnect Stator, and connect the C terminal to B-, the set point should be 12.6+/-0.2V.3. Disconnect C terminal, push the Over Voltage button on the panel, the Lamp Indicator comes on.
• Lamp Activated• With soft start and LRC• Over Voltage Lamp function
11/21/2014Revision: Date :Product Group464Page
![Page 467: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/467.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN373 A 24 28.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator comes on, and the Field Circuit LED comes dim.2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indicator comes on.
Ignition ActivatedActive Lamp -- With OutputWith Soft Start
11/21/2014Revision: Date :Product Group465Page
![Page 468: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/468.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D10
D10SE8
D10SE24
DE608
A
A
A
A
12
8
24
12
14.8
9.6
27.5
14.7
VOLTFLD SET POINTPART NO.
D21
DE610
D30
A
A
A
12
12
24
14.0
14.7
27.5
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :D-01Product Group466Page
![Page 469: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/469.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IY145 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should be 15.3+/-0.2v.
Light Activated.
11/21/2014Revision: Date :Product Group467Page
![Page 470: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/470.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB5353 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Remove test lead from terminal marked "Stator" - the Field light and Lamp will come on andVoltage will show 12 volts.
Push the Choke Drive button on the panel, the Choke Drive Indicator will come on.
• L-FR Terminals• With LRC and Soft Start• Active Lamp Circuit - with Output• VRC101-34 adapter shown for enhance stator signal, not all late model regulators need enhance signal
11/21/2014Revision: Date :Product Group468Page
![Page 471: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/471.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6308 B 12 14.45
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator comes on and the Field Circuit LED will dim.
Light ActivatedSoft Start2.2s LRC
11/21/2014Revision: Date :Product Group469Page
![Page 472: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/472.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M512HD A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Push the Over Voltage button on the panel, the Lamp Indicator comes on.2. Disconnect Stator, the Lamp Indicator comes on.
Ignition ActivatedWith Soft StartOver Voltage and Under Voltage lamp
11/21/2014Revision: Date :Product Group470Page
![Page 473: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/473.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN348 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator comes on.2. Reconnect Stator, Push the Choke Drive button on the panel, the Choke Drive Indicator should be on.
Ignition ActivatedSoft StartUnder Voltage LampP-IG-L Terminal FunctionActive Lamp -- With Output
11/21/2014Revision: Date :Product Group471Page
![Page 474: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/474.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMANDO
VOLTFLD SET POINTPART NO.
IY289 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should be 15.6+/-0.2V.
Ignition Activated.
11/21/2014Revision: Date :Product Group472Page
![Page 475: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/475.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IB347 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group473Page
![Page 476: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/476.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH743 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint is 15.3+/-0.2V2. Reconnect Sense, connected C to B-, the setpoint should be 12.75+0.25/-0.15V.3. Disconnect C, disconnect Stator, the Lamp Indicator comes on.4. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.
Lamp Activated.Over Voltage, Under Voltage Lamp.
11/21/2014Revision: Date :Product Group474Page
![Page 477: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/477.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM844 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Connect C to B-, the setpoint should be 12.6-0.5/+0.4V.
Ignition Activated.Trio input turns off charge indicator lamp.
11/21/2014Revision: Date :Product Group475Page
![Page 478: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/478.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN454 B 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the Lamp Indicator comes on.
Stator or Light Activated.Under Voltage LampSoft Start & LRC function.
11/21/2014Revision: Date :Product Group476Page
![Page 479: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/479.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M527 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.1. disconnect Stator, the Lamp Indicator comes on, and the Field Circuit led should be dim.2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indicator comes on.
Stator Activated.Soft Start & LRC functionActive Lamp -- With Output
11/21/2014Revision: Date :Product Group477Page
![Page 480: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/480.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6329 B 12 13.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Use VRC2010 tester to complete RC voltage setpoint testing:1. Connect RC terminal to VRC2010 tester.2. Adjust Comm Voltage switch to position 13, Setpoint is 11.8.3. Adjust Comm Voltage switch to position 14, Setpoint is 13.3V.4. Adjust Comm Voltage switch to position 15, Setpoint is 14.4V.* The 13.8V Set Point indicate above is the 'default VSet' (no vehicle PCM input).
Stator or RVC Activated
11/21/2014Revision: Date :Product Group478Page
![Page 481: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/481.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D2206 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator comes on.2. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator should be on.3. Push the Field Diode button on the panel, the Field Diode LED should be on.
Soft Start & LRC functionIgnition or Light ActivatedOver Voltage and Under Voltage LampStandard Lamp -- Without output
11/21/2014Revision: Date :Product Group479Page
![Page 482: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/482.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB861 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator comes on.2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indicator comes on.
Stator or Light Activated.Soft Start & LRC functionActive Lamp -- With Output
11/21/2014Revision: Date :Product Group480Page
![Page 483: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/483.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM472HD A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should be 15.6+/-0.2V.2. Reconnect sense, and connect C to B-, the setpiont should be 12.7+/-0.2V.3. Disconnect C, Disconnect Stator, the Lamp Indicator comes on.4. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator should be on.
Light ActivatedSoft Start & LRC functionWith C-functionOver Voltage LampStandard Lamp -- Without Output
11/21/2014Revision: Date :Product Group481Page
![Page 484: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/484.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB677 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator comes on.2. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.3. Push the Choke Drive button on the panel, the Choke Drive Indicator comes on.
Light or Stator ActivatedSoft Start2 seconds LRCOver Voltage LampActive Lamp -- With Output
11/21/2014Revision: Date :Product Group482Page
![Page 485: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/485.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D3232 B 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should be 14.2+/-0.2V.2. Reconnect Sense,disconnect Stator, the Lamp Indicator comes on.3. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.
Light ActivatedSoft Start2.5s LRC functionOver Voltage, Under Voltage LampStandard Lamp -- Without Output
11/21/2014Revision: Date :Product Group483Page
![Page 486: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/486.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB307BZ B 24 28.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Trio Excited.Trio connected to Light
11/21/2014Revision: Date :Product Group484Page
![Page 487: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/487.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB308BZ B 24 28.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Trio Excited.Trio connected to Light.
11/21/2014Revision: Date :Product Group485Page
![Page 488: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/488.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH741 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect the C terminal to VRC2010,push the COMPUTER button to check the C function.1. Disconnect Sense, the setpoint should be 15.2+/-0.2V2. Reconnect Sense, disconnect Stator, the Lamp Indicator comes on.3. Reconnect Stator, connect C to VRC2010, the setpoint should be 13.0+/-0.2V.
Light Activated.Soft start9s LRCField, Lamp short circuit protectionStandard Lamp, without output
11/21/2014Revision: Date :Product Group486Page
![Page 489: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/489.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM545 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator comes on.2. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.
Soft Start2.5s LRCLight ActivatedOver Voltage, Under Voltage LampStandard Lamp -- Without Output
11/21/2014Revision: Date :Product Group487Page
![Page 490: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/490.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM564 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should be 15.6V+/-0.2v, the Lamp Indicator comes on.2. Reconnect Sense, disconnect Stator, the Lamp Indicator should be on.3. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.
Light Activated.Soft Start function5.5s LRCOver Voltage LampStandard Lamp -- Without output
11/21/2014Revision: Date :Product Group488Page
![Page 491: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/491.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH737 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should be 15.3+/-0.2V.2. Reconnect Sense, disconnect Stator, the Light should be on.
Light Activated.Soft Start9.2 seconds LRCStandard Lamp -- Without Output
11/21/2014Revision: Date :Product Group489Page
![Page 492: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/492.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH745 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should be 15.3+/-0.2V.2. Reconnect Sense, disconnect Stator, the Light should be on.
Light Activated.Soft Start9 seconds LRCStandard Lamp -- Without Output
11/21/2014Revision: Date :Product Group490Page
![Page 493: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/493.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHARLEY
VOLTFLD SET POINTPART NO.
H8615 A 12 15.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group491Page
![Page 494: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/494.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB227 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Push the Over Voltage button on the panel, the Lamp Indicator comes on.2. Disconnect Stator, the Lamp Indicator comes on.
Light ActivatedSoft Start3 seconds LRCOV, UV Lamp
11/21/2014Revision: Date :Product Group492Page
![Page 495: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/495.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM547 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should me 15.5+/-0.2V.2. Reconnect Sense, connect C to B-, the setpoint should be 13.1+/-0.2V.3. Disconnect C, disconnect Stator, the Lamp Indication comes on.4. Reconnect Stator, the Lamp Indication comes on
Light Activated.Soft Start function.6 seconds LRCField, Lamp short circuit protectionStandard Lamp -- Without Output
11/21/2014Revision: Date :Product Group493Page
![Page 496: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/496.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M550 B 12 14.45
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.1. Disconnect Stator, the Lamp Indicator comes on.
Stator or Light Activated.Soft Start function.4 seconds LRCUnder Voltage LampStandard Lamp -- Without Output
11/21/2014Revision: Date :Product Group494Page
![Page 497: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/497.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M511V A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Trio Excited.
11/21/2014Revision: Date :Product Group495Page
![Page 498: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/498.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6365 B 12 14.35
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator comes on.2. Reconnect Stator, connect C terminal to B-, the setpoint should be 12.7+/-0.2V.
Ignition Activated.C functionStandard Lamp Function -- Without Output.
11/21/2014Revision: Date :Product Group496Page
![Page 499: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/499.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6366 B 12 14.46
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator comes on.2. Reconnect Stator, connect C terminal to B-, the setpoint should be 12.8+/-0.2V.
Ignition Activated.C function12 seconds LRCStandard Lamp -- Without Output
11/21/2014Revision: Date :Product Group497Page
![Page 500: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/500.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN332 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indication comes on.
Ignition Activated.Soft start.9 seconds LRC.Under voltage Lamp
11/21/2014Revision: Date :Product Group498Page
![Page 501: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/501.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB313 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indication comes on.2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indication comes on.
Soft Start function2 seconds LRCStator or Light ActivatedActive Lamp function -- With Output
11/21/2014Revision: Date :Product Group499Page
![Page 502: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/502.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M544 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.1. Disconnect stator, the Lamp Indication comes on.
Stator Activated.Soft Start FunctionUnder Voltage Lamp.
11/21/2014Revision: Date :Product Group500Page
![Page 503: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/503.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN265 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indication comes on.
Ignition Activated.
11/21/2014Revision: Date :Product Group501Page
![Page 504: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/504.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM505 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect DRIVER to tester “PD”
11/21/2014Revision: Date :Product Group502Page
![Page 505: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/505.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IL7020JMP A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
TRIO Excited.
11/21/2014Revision: Date :Product Group503Page
![Page 506: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/506.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M564 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.1. Disconnect Stator, the Lamp Indication comes on.2. Reconnect Stator, Push “Choke Drive” on the panel, the Choke Drive Indication comes on.
Stator or Light ActivatedSoft Start Function5 seconds LRCUnder Voltage LampActive Lamp -- With Output
11/21/2014Revision: Date :Product Group504Page
![Page 507: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/507.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M546 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.1. Disconnect Stator, the Lamp Indication comes on.2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indication comes on.
Stator or Light Activated.Soft Start Function9 seconds LRCUnder Voltage LampActive Lamp -- With Output
11/21/2014Revision: Date :Product Group505Page
![Page 508: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/508.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH784 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
TRIO EXCITED
11/21/2014Revision: Date :Product Group506Page
![Page 509: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/509.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M6120 A 12 14.65
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
TRIO excited.
11/21/2014Revision: Date :Product Group507Page
![Page 510: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/510.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M6132 A 12 14.65
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
TRIO excited
11/21/2014Revision: Date :Product Group508Page
![Page 511: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/511.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN266 A 24 28.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Ignition Activated.
11/21/2014Revision: Date :Product Group509Page
![Page 512: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/512.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M549 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.1. Disconnect Stator, the Lamp Indication comes on.2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indication comes on.
Stator or Light Activated.Soft Start Function9 seconds LRCUnder Voltage LampActive Lamp -- With Output
11/21/2014Revision: Date :Product Group510Page
![Page 513: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/513.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
TRI738 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should be 15.3+/-0.2V.2. Reconnect Sense, disconnect Stator, the Lamp Indication should be on.3. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indication should be on.
Soft Start Function3 seconds LRCOver Voltage, Under Voltage Lamp.
11/21/2014Revision: Date :Product Group511Page
![Page 514: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/514.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M564 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.1. Disconnect Stator, the Lamp Indication comes on.2. Reconnect Stator, Push “Choke Drive” on the panel, the Choke Drive Indication comes on.
Stator or Light ActivatedSoft Start Function5 seconds LRCUnder Voltage LampActive Lamp -- With Output
11/21/2014Revision: Date :Product Group512Page
![Page 515: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/515.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLUCAS
VOLTFLD SET POINTPART NO.
IL7044JMP A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Trio Excited.
11/21/2014Revision: Date :Product Group513Page
![Page 516: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/516.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLUCAS
VOLTFLD SET POINTPART NO.
IL217 A 12 14.25
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Trio Excited.
11/21/2014Revision: Date :Product Group514Page
![Page 517: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/517.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M534 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.1. Disconnect Sense, the set point should be 14.3V, the Lamp Indication should be on.2. Reconnect Sense, Disconnect Stator, the Lamp Indication should be on.
Stator ActivatedSoft Start Function6s LRCUnder Voltage Lamp
11/21/2014Revision: Date :Product Group515Page
![Page 518: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/518.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M540 B 12 13.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RVC terminal to VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 11.8V.2. Adjust Comm Voltage switch to position 14, Setpoint is 13.3V.3. Adjust Comm Voltage switch to position 15, Setpoint is 14.4V.
RC or Stator Activated.Soft Start FunctionVSet controlled by vehicle RVC system
11/21/2014Revision: Date :Product Group516Page
![Page 519: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/519.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M558 B 12 14.65
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.1. Disconnect Stator, the Lamp Indication should be on.
•B-Circuit, High side drive regulator•Stator or Lamp Activated•Soft Start•3 seconds LRC•Under Voltage Lamp
11/21/2014Revision: Date :Product Group517Page
![Page 520: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/520.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB680 B 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Push the Choke Drive button on the panel, the Choke Drive Indicator comes on.2. Disconnect Stator, the Lamp Light comes on, the Field Lamp is dim.
soft start function8 seconds LRCActive Lamp function -- With OutputStator or Light Activated.
11/21/2014Revision: Date :Product Group518Page
![Page 521: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/521.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI MARELLI
VOLTFLD SET POINTPART NO.
IX124 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator should be on.2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indicator should be on.
IL or Stator Activated.Active Lamp -- With Output
11/21/2014Revision: Date :Product Group519Page
![Page 522: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/522.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M531 B 12 14.45
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.1. Disconnect Stator, the Lamp Indicator should be on.
Soft Start Function5 seconds LRCUnder Voltage LampStator Activated.
11/21/2014Revision: Date :Product Group520Page
![Page 523: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/523.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D104HD-264 A 24 26.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :1Product Group521Page
![Page 524: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/524.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M5-332 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. test with VRC2010 disconnect sense, the set point(DMM) is about 15.4V, the Lamp indicator is on
A circuit
11/21/2014Revision: Date :Product Group522Page
![Page 525: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/525.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH746 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should be 15.3+/-0.2V.2. Reconnect Sense, disconnect Stator, the Light should be on.
Light Activated.Soft Start9 seconds LRCStandard Lamp -- Without Output
11/21/2014Revision: Date :Product Group523Page
![Page 526: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/526.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM264-2 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
disconnect the SENSE, the setpoint(DMM reading) is about 15.2V
11/21/2014Revision: Date :Product Group524Page
![Page 527: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/527.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN289 A 12 13.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Sense, the setpoint should be about 14.5V. lamp on2. Reconnect Sense, disconnect Stator, the Light should be on.
A circuit, low side drivewith softstartwith LRCIGN actived
11/21/2014Revision: Date :Product Group525Page
![Page 528: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/528.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH747 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
disconnect the SENSE, the setpoint is about 15.2V, lamp is on
A circuit, low side drivelight activatedwith LRCwith soft startwith C function
11/21/2014Revision: Date :Product Group526Page
![Page 529: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/529.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M557 B 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
disconnect the stator, lamp is on
B circuit, high side drivewith soft startwith under voltage
11/21/2014Revision: Date :Product Group527Page
![Page 530: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/530.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB389 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
A circuitwith LRC
11/21/2014Revision: Date :Product Group528Page
![Page 531: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/531.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB160 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
B circuit,low side driveSTA activated and light activated to softstartwithout LRCwith softstartwith F function
11/21/2014Revision: Date :Product Group529Page
![Page 532: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/532.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IX597 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
A circuitwithout LRCwith choke drive
11/21/2014Revision: Date :Product Group530Page
![Page 533: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/533.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
M5-2471 A 24 27.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
A circuit,low side driveSTA actived
11/21/2014Revision: Date :Product Group531Page
![Page 534: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/534.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M556 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
disconnect the SENSE,the setpiont is about 15.0V.
B circuit,high side drivelight/stator activatedwith LRCwith C functionwith soft start
11/21/2014Revision: Date :Product Group532Page
![Page 535: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/535.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB266
IB266V
A
A
12
12
14.2
14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.
A circuit,low side driveLight/Stator activatedwith softstartwith LRCwith FR function
11/21/2014Revision: Date :Product Group533Page
![Page 536: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/536.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsFORD
VOLTFLD SET POINTPART NO.
F611 A 12V 14.0*
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Use VRC2010 tester to complete RC voltage setpoint testing:1. Connect RC terminal to VRC2010 tester.2. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.3. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.4. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.* The 14.0V Set Point indicate above is the 'default VSet' (no vehicle PCM input).
11/21/2014Revision: Date :F-12Product Group534Page
![Page 537: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/537.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB5300 B 24 25.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
B circuit,high side driveIgnition activatedwith softstartwith FR function
11/21/2014Revision: Date :Product Group535Page
![Page 538: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/538.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN249 A 12 14.65
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
A circuit,low side drive
11/21/2014Revision: Date :Product Group536Page
![Page 539: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/539.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
M552 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Disconnect the Stator terminal and the Lamp should turn ON.
B circuit, high side drivewith softstartwith LRCwith FR
11/21/2014Revision: Date :Product Group537Page
![Page 540: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/540.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
DE708HD
DE708HD-B-V1
B
B
12
12
14.7
14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
B circuit, high side driveLight activedwith softstartwith LRC
11/21/2014Revision: Date :Product Group538Page
![Page 541: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/541.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D2262 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group539Page
![Page 542: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/542.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN462 A 24 28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Stator terminal and the Light should turn ON.Reconnect the Stator terminal, push the Over Voltage button, the light should turn ON.
11/21/2014Revision: Date :Product Group540Page
![Page 543: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/543.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB9028 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group541Page
![Page 544: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/544.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMOTOROLA
VOLTFLD SET POINTPART NO.
M5-050AHD A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the Choke switch and the "Choke Drive" will turn on.
11/21/2014Revision: Date :Product Group542Page
![Page 545: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/545.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLEECE
VOLTFLD SET POINTPART NO.
L105746 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group543Page
![Page 546: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/546.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN373HD A 24 28.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
1. Disconnect Stator, the Lamp Indicator comes on.2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indicator comes on.
Ignition Activated
11/21/2014Revision: Date :Product Group544Page
![Page 547: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/547.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO/MOTOROLA
VOLTFLD SET POINTPART NO.
M516SC-2 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the "Over Voltage" switch and the "Lamp Indicator" will turn on.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group545Page
![Page 548: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/548.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM688 A 24 28.45
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the choke drive and the "Choke Drive Indicator Lamp" will turn on.Disconnect the SENSE, Lamp will turn on.Reconnect SENSE, Lamp will turn off, disconnect the Stator, Lamp will turn on.
11/21/2014Revision: Date :Product Group546Page
![Page 549: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/549.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsValeo
VOLTFLD SET POINTPART NO.
M561 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the choke drive and the "Choke Drive Indicator Lamp" will turn on,Disconnect the Stator terminal, the Lamp should turn ON.
11/21/2014Revision: Date :Product Group547Page
![Page 550: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/550.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI MARELLI
VOLTFLD SET POINTPART NO.
IX135 B 12 13.5*
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Use VRC2010 tester to complete RC voltage setpoint testing,Connect C terminal to RCV of VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 13.0V.2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.3. Adjust Comm Voltage switch to position 15, Setpoint is 15.0V.* The 13.5V Set Point indicate above is the 'default VSet' (no vehicle PCM input), disconnect the Sense, the set point will be13.9V +/-0.2V, and the Lamp Indicator comes on.
11/21/2014Revision: Date :Product Group548Page
![Page 551: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/551.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMANDO
VOLTFLD SET POINTPART NO.
IY116 A 12 14.45
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect Sense, the Lamp Indicator comes on, and the set point will be 15.4V +/-0.2V.
11/21/2014Revision: Date :Product Group549Page
![Page 552: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/552.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM558 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect IGNITION with B+, Connect COMPUTER terminal to C of VRC2010 tester. don’t connect FR.Push the "Over Voltage" switch and the "Lamp Indicator" will turn on.Push the "COMPUTER" switch and the Setpoint drops to 12.6V.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group550Page
![Page 553: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/553.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsHITACHI
VOLTFLD SET POINTPART NO.
IH748 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Sense, the set point will be 15.4V +/-0.2V.Reconnect Sense, disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group551Page
![Page 554: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/554.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM622 A 12 13.45
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect RC.Disconnect the Sense, the set point will be 14.0V +/-0.2V.Connect RC terminal to RCV of VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 13.0V.2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.3. Adjust Comm Voltage switch to position 15, Setpoint is 15.0V.
11/21/2014Revision: Date :Product Group552Page
![Page 555: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/555.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB6024 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group553Page
![Page 556: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/556.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB321 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group554Page
![Page 557: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/557.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM992 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Sense, the set point will be 15.5V +/-0.3V.
11/21/2014Revision: Date :Product Group555Page
![Page 558: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/558.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMANDO
VOLTFLD SET POINTPART NO.
IY727 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO and SENSE to B+.Disconnect the Sense, the set point will be 15.5V +/-0.3V.
11/21/2014Revision: Date :Product Group556Page
![Page 559: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/559.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB362CN-2 A 24 28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group557Page
![Page 560: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/560.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6601 A 12 13.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to RCV of VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 13.0V.2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.3. Adjust Comm Voltage switch to position 15, Setpoint is 15.0V.
11/21/2014Revision: Date :Product Group558Page
![Page 561: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/561.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M530 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group559Page
![Page 562: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/562.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M560 B 12 14.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group560Page
![Page 563: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/563.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IN6315T B 12 14.35
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal C with B-, Setpoint drops to 12.7+/-0.2V.
11/21/2014Revision: Date :Product Group561Page
![Page 564: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/564.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLingshan
VOLTFLD SET POINTPART NO.
IP129BCN A 24 28.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group562Page
![Page 565: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/565.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
M524T B 12 14.65
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group563Page
![Page 566: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/566.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsGauss
VOLTFLD SET POINTPART NO.
PG102
PG126
A
A
12
12
14.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Sense, the set point will be 16.2V +/-0.3V.
11/21/2014Revision: Date :Product Group564Page
![Page 567: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/567.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDenso
VOLTFLD SET POINTPART NO.
IX137 B 12 13.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to RCV of VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 13.0V.2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.3. Adjust Comm Voltage switch to position 15, Setpoint is 15.0V.
11/21/2014Revision: Date :Product Group565Page
![Page 568: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/568.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIKKO
VOLTFLD SET POINTPART NO.
IZ228 A 24 28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect Sense, B+ and Trio to VRC B+.
11/21/2014Revision: Date :Product Group566Page
![Page 569: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/569.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBosch
VOLTFLD SET POINTPART NO.
IB381HD A 24 28.05
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group567Page
![Page 570: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/570.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPON Denso
VOLTFLD SET POINTPART NO.
IN6003SE B 12 15.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Stator terminal and the Lamp should turn ON.Reconnect the Stator terminal, disconnect the Sense, the set point will be 15.15V +/-0.2V, and the Lamp shouldturn ON.
11/21/2014Revision: Date :Product Group568Page
![Page 571: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/571.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB368SE A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group569Page
![Page 572: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/572.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO MOTOROLA
VOLTFLD SET POINTPART NO.
M562 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group570Page
![Page 573: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/573.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB6026
IB6026CN
IB6026V
B
B
B
12
12
12
14.5
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the choke drive and the "Choke Drive Indicator Lamp" will turn on.Disconnect the Stator terminal and the Light should turn ON.
Switch the STATOR to 450Hz.
11/21/2014Revision: Date :Product Group571Page
![Page 574: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/574.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M571 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch "COMMVOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group572Page
![Page 575: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/575.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI MARELLI
VOLTFLD SET POINTPART NO.
IX594 A 12 14.45
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group573Page
![Page 576: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/576.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M574 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group574Page
![Page 577: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/577.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsGauss
VOLTFLD SET POINTPART NO.
PG103 A 24 29.1
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect IGN, the setpoint should be 29.1+/-0.3V.Reconnect the IGN terminal, and disconnect TRIO, the setpoint will rise a little bit.
11/21/2014Revision: Date :Product Group575Page
![Page 578: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/578.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsGauss
VOLTFLD SET POINTPART NO.
PG101 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect IGN, the setpoint should be 14.6+/-0.3V.Reconnect the IGN terminal, and disconnect TRIO, the setpoint will rise a little bit.
11/21/2014Revision: Date :Product Group576Page
![Page 579: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/579.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsGauss
VOLTFLD SET POINTPART NO.
PG133 A 24 28.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect IGN, the setpoint should be 28.6+/-0.3V.Reconnect the IGN terminal, and disconnect TRIO, the setpoint will rise a little bit.
11/21/2014Revision: Date :Product Group577Page
![Page 580: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/580.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB6056 B 12 13.9*
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to LIN of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.* The 13.9V Set Point indicate above is the 'default VSet' (no LIN input).
11/21/2014Revision: Date :Product Group578Page
![Page 581: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/581.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB5356 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Booting time is 12.6s.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group579Page
![Page 582: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/582.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB387CN-B160 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group580Page
![Page 583: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/583.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6011 B 12 14.45
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the "Over Voltage" switch and the "Lamp Indicator" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.Reconnect the Stator terminal, disconnect the Sense, the set point will be 14.45V +/-0.2V.
11/21/2014Revision: Date :Product Group581Page
![Page 584: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/584.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB238 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group582Page
![Page 585: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/585.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
PG104 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+ of VRC2010.Disconnect the Sense, the set point will be 15.7V +/-0.2V.
11/21/2014Revision: Date :Product Group583Page
![Page 586: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/586.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM295
IM295CN
A
A
12
12
14.8
14.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO and IGN to B+.
11/21/2014Revision: Date :Product Group584Page
![Page 587: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/587.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB003 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+ of VRC2010.
11/21/2014Revision: Date :Product Group585Page
![Page 588: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/588.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN372 A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Connect IGN and SENS to B+, the setpoint is 14.2+/-0.2V.Disconnect SENS, the setpoint goes to 14.5+/-0.2V and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group586Page
![Page 589: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/589.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB313
IB313S
A
A
12
12
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group587Page
![Page 590: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/590.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB6037 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to LIN of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group588Page
![Page 591: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/591.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M543 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch "COMMVOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group589Page
![Page 592: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/592.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D411HD-HM B 12 14.8
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the "Over Voltage" switch and the "Lamp Indicator" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.Reconnect the Stator terminal, disconnect the Sense, the set point will be 14.8V +/-0.25V.
11/21/2014Revision: Date :Product Group590Page
![Page 593: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/593.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB293 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch "COMM
VOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group591Page
![Page 594: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/594.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB6132 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch "COMM
VOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group592Page
![Page 595: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/595.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM473 A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect SENSE, the Setpoint should be 15.6 +/-0.2V and the Lamp turn ON.Reconnect the SENSE terminal, disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group593Page
![Page 596: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/596.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M573 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to LIN of VRC2010, the SET POINT is adjustable and goes with the switch "COMMVOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group594Page
![Page 597: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/597.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
P8-393HD B 24 27.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group595Page
![Page 598: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/598.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M579 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group596Page
![Page 599: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/599.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
M5-329AHD A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Stator terminal, the regulator should stop works.
11/21/2014Revision: Date :Product Group597Page
![Page 600: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/600.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IN437SERP A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group598Page
![Page 601: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/601.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB6197 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to LIN of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group599Page
![Page 602: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/602.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M576 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to LIN of VRC2010, the SET POINT is adjustable and goes with the switch "COMMVOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group600Page
![Page 603: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/603.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB5378 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to LIN of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group601Page
![Page 604: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/604.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
M5-280AHD A 12 14.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Stator terminal, the regulator should stop works.
11/21/2014Revision: Date :Product Group602Page
![Page 605: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/605.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB6135 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group603Page
![Page 606: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/606.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDenso
VOLTFLD SET POINTPART NO.
IX136 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the IGN terminal, the regulator should stop works.
11/21/2014Revision: Date :Product Group604Page
![Page 607: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/607.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M575 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group605Page
![Page 608: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/608.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M572 B 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group606Page
![Page 609: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/609.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
M5-338 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Stator terminal, the regulator should stop works.
11/21/2014Revision: Date :Product Group607Page
![Page 610: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/610.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM362 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the "Over Voltage" switch and the "Lamp Indicator" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.Reconnect the Stator terminal, disconnect the Sense, the "Lamp Indicator" will turn on and the set point will be15.5V +/-0.2V.
11/21/2014Revision: Date :Product Group608Page
![Page 611: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/611.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB885 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to LIN of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group609Page
![Page 612: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/612.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB059 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Stator terminal and the Lamp should turn ON.Reconnect the Stator terminal, disconnect the Sense, the Lamp should turn ON and set point will be 14.5V +/-0.2V.
11/21/2014Revision: Date :Product Group610Page
![Page 613: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/613.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IZ229 A 24 28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group611Page
![Page 614: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/614.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB5289 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group612Page
![Page 615: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/615.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IP2700V A 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group613Page
![Page 616: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/616.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M568 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to LIN of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group614Page
![Page 617: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/617.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
D940-132 A 12 13.2
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect SENSE and TRIO to B+.
11/21/2014Revision: Date :Product Group615Page
![Page 618: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/618.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM849 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Sense, the set point will be 15.7V +/-0.3V.
11/21/2014Revision: Date :Product Group616Page
![Page 619: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/619.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M566 A 12 13.6*
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.1. Adjust Comm Voltage switch to position 13, Setpoint is 13.0V.2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.3. Adjust Comm Voltage switch to position 15, Setpoint is 15.0V.* The 13.6V Set Point indicate above is the 'default VSet' (no vehicle PCM input).
11/21/2014Revision: Date :Product Group617Page
![Page 620: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/620.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M591 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to LIN of VRC2010, the SET POINT is adjustable and goes with the switch ‘COMMVOLTAGE’ to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group618Page
![Page 621: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/621.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M542 B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group619Page
![Page 622: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/622.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IP1903
IP1903V
A
A
12
12
14.6
14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group620Page
![Page 623: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/623.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN6335CN B 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Connect C to B-, the setpoint should be 12.85+/-0.2V.Disconnect C, disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group621Page
![Page 624: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/624.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN393 A 12 14.25
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.Reconnect the Stator, disconnect Sense, the Lamp should turn ON and the set point will be 14.6V +/-0.2V.
11/21/2014Revision: Date :Product Group622Page
![Page 625: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/625.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsNIPPONDENSO
VOLTFLD SET POINTPART NO.
IN456 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR and C terminal.Push the Choke switch and the "Choke Drive" will turn on.Push the "Over Voltage" switch and the "Lamp Indicator" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.Reconnect Stator, connect C with GND, the set point will be 12.6V +/-0.2V.
11/21/2014Revision: Date :Product Group623Page
![Page 626: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/626.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO MOTOROLA
VOLTFLD SET POINTPART NO.
M578 B 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.
11/21/2014Revision: Date :Product Group624Page
![Page 627: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/627.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB6066 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch "COMMVOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group625Page
![Page 628: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/628.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM691 A 24 28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Sense, the set point will be 28.5V +/-0.2V.Reconnect Sense, disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group626Page
![Page 629: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/629.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB6011 B 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group627Page
![Page 630: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/630.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M521 B 12 14.45
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group628Page
![Page 631: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/631.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM847 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Sense, the set point will be 15.5V +/-0.3V.
11/21/2014Revision: Date :Product Group629Page
![Page 632: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/632.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB276 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.Disconnect the Stator terminal and the Lamp should turn ON.
11/21/2014Revision: Date :Product Group630Page
![Page 633: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/633.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB678 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch "COMMVOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group631Page
![Page 634: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/634.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB510 A 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.Disconnect the Sense, the set point will be 14.5V +/-0.3V.
11/21/2014Revision: Date :Product Group632Page
![Page 635: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/635.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M547 B 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.Push the Choke switch and the "Choke Drive" will turn on.
11/21/2014Revision: Date :Product Group633Page
![Page 636: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/636.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB262 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch "COMMVOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group634Page
![Page 637: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/637.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB6866 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch "COMMVOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group635Page
![Page 638: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/638.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsLUCAS
VOLTFLD SET POINTPART NO.
IL225 A 24 28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group636Page
![Page 639: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/639.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M545 B 12 14.6
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch "COMMVOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group637Page
![Page 640: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/640.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D805 B 24 28.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Sense, the set point will be 28.3V +/-0.3V.Disconnect the IGN, the regulator should stop works.
11/21/2014Revision: Date :Product Group638Page
![Page 641: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/641.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IP135BNV
IP135BN
A
A
12
12
14.3
14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group639Page
![Page 642: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/642.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsVALEO
VOLTFLD SET POINTPART NO.
M511V-G64 A 12 14.15
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group640Page
![Page 643: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/643.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IP729BNV
IP729BN
A
A
24
24
28.5
28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group641Page
![Page 644: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/644.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulators
VOLTFLD SET POINTPART NO.
IP129BNV
IP129BN
IP129BN-285V
IP129BN-285
A
A
A
A
24
24
24
24
27.5
27.5
28.5
28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group642Page
![Page 645: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/645.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB5881 B 12 14.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to BSS of VRC2010, the SET POINT is adjustable and goes with the switch "COMMVOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group643Page
![Page 646: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/646.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB6150 B 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal to LIN of VRC2010, the SET POINT is adjustable and goes with the switch "COMMVOLTAGE" to 13V, 14V or 15V, range is +/-0.2V.
11/21/2014Revision: Date :Product Group644Page
![Page 647: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/647.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB363T A 24 28.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group645Page
![Page 648: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/648.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB351T A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group646Page
![Page 649: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/649.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB387T A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group647Page
![Page 650: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/650.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB385T A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect TRIO to B+.
11/21/2014Revision: Date :Product Group648Page
![Page 651: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/651.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB350T
IB353T
IB355T
A
A
A
12
12
12
14.2
14.5
14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group649Page
![Page 652: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/652.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB388T A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group650Page
![Page 653: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/653.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBOSCH
VOLTFLD SET POINTPART NO.
IB5225 A 12 14.5
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Do not connect the FR terminal.• Push the Choke switch and the "Choke Drive" will turn on.• Remove white test lead from terminal marked "Stator" - the Field light and Lamp will come on and
Voltage will show 12 volts.• Remove green test lead from "light" terminal , field light will go out and voltage stays at 12 volts.
11/21/2014Revision: Date :Product Group651Page
![Page 654: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/654.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsBosch
VOLTFLD SET POINTPART NO.
IB543 B 24 28.3
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Stator terminal and the Lamp should turn ON.Reconnect the Stator terminal, disconnect the Sense, the Lamp should turn ON.
11/21/2014Revision: Date :Product Group652Page
![Page 655: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/655.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsDELCO
VOLTFLD SET POINTPART NO.
D10ACBD B 12 14.0
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Disconnect the Stator terminal, the regulator should stop works.
11/21/2014Revision: Date :Product Group653Page
![Page 656: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/656.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMAGNETI MARELLI
VOLTFLD SET POINTPART NO.
IX491 A 12 14.4
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
11/21/2014Revision: Date :Product Group654Page
![Page 657: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/657.jpg)
for
TRANSPO TESTER INSTRUCTIONStype regulatorsMITSUBISHI
VOLTFLD SET POINTPART NO.
IM569 A 12 14.7
VOLTFLD SET POINTPART NO.
3. Amendments or Additional Tests:
1. POWER OFF:
2. POWER ON:
Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulatoras indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
Tester field lamp should blink and tester meter should indicate the approximiate Set PointVoltage noted in the table above.
Connect terminal COMPUTER with B-, Setpoint drops to 12.8V.
11/21/2014Revision: Date :Product Group655Page
![Page 658: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/658.jpg)
Notes
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
![Page 659: VRC2010 Tester Manual 2015](https://reader031.vdocuments.us/reader031/viewer/2022012301/584c30c71a28ab85738e516d/html5/thumbnails/659.jpg)
CANADAMontréal4711 Boul. CoutureMontréal (St-Léonard), Québec, H1R 3H7 Tel: 514.324.7922Toll Free: 800.661.2962Fax: 514.328.1535
Toronto34 Alex AvenueVaughan, OntarioL4L 5X1 Tel: 416.740.9200Toll Free: 800.387.2807Fax: 416.740.5348
EUROPE WAI Europe b.v.Klappolder 2252665 MR BleiswijkThe NetherlandsTel: 31(0)10.524.1980Fax: 31(0)10.524.1981
CHINATranspo Electronics, Shanghai, LTDBuilding No. 32 215 De Bao RdWai Gao Qiao Free Trade ZonePudong, Shanghai 200131 Peoples Republic of ChinaTel: 86.21.5048.2700Fax: 86.21.5048.2722
USAWAIglobal USA411 Eagleview Blvd., Suite 100, Exton, PA 19341Tel: 484.875.6600Toll Free: 800.877.3340 Fax: 800.948.6121
BRAZIL WAIglobal Brazil Ltda Av. Coronel Marcos Konder, 1207-Sala 7088.301-303, Itajai-SCTel/Fax: (47)3046.1600
ww
w.w
aiglobal.comC
M
Y
CM
MY
CY
CMY
K