vp40 nd 2 textfile/06standardpk.com/en_ds/valves/en_6.6.020.pdf · 2012. 12. 17. · vp40 nd 2 n/**...
TRANSCRIPT
11/99 N/** 6.6.020.01Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
VP40
3 Way Proportional Pressure Control Valve
Nominal diameter 2Direct operated poppet valves
Flange design
Low hysteresis
Good repeatability
High flow capacity at exhaust port
Manifold mountable system
Compact design
Technical DataMedium:
Filtered air, lubricated or unlubricated,Filter 50 µm
Operation:Proportional solenoid
Connection:Flange, subplate
Flow direction:Fixed
Operating pressure p1:16 bar max.
Pressure setting p2:0 to 16 bar
Ambient temperature:-10 to +40 °C
Hysteresis:< 3 % (IN, p2 max)
Repeatability: *< 1 % (p2 max)
Linearity: *See characteristic curve
Response sensitivity: *≤ 1 % (p2 max)
Degree of protection:IP 65 with connector
Mounting:Any position
Materials:Body aluminium alloySeals NBR (Perbunan)
*Values referred to 20 °C with dither 20 % IN, 50 Hz
Ordering Information3 way proportional pressure control valve, ND 2,pressure setting 0 to 10 bar,Type: 4090020.7093.012.00
Subplate must be ordered separately.
2
3 1
ConnectorsSee data sheet 7503364
Symbol
VP40 ND 2
N/** 6.6.020.02 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
General Information
Type Nominal diameter Connection Pressure Max. Operating Rated Current Drive WeightSetting p2 (bar) Pressure p1 (bar) (mA) Electronics (kg)
4090021.7093.012.00 2 Flange 0 to 6 7 805 pQ11, pQ12, pQ04 0,28
4090020.7093.012.00 2 Flange 0 to 10 12 1050 pQ11, pQ12, pQ04 0,28
4090022.7093.012.00 2 Flange 0 to 16 16 1500 pQ11, pQ12, pQ04 0,28
Voltage 12 V DC
Limiting current IN 1930 mA
Rated power PN 25 W
Resistance R20 6,3 Ω +3%
Duty cycle 100 %
Electrical Information for Proportional Solenoids
Drive ElectronicspQ11
Type Rated Current Electrical connection Remarks Description(mA)
5980083 0 to 1000 Connector acc. to DIN 43651 Suitable for 4090020.70935980087 0 to 1000 2 m Cable and 4090021.7093 valves
5980118 0 to 2400 Connector acc. to DIN 43651 Suitable for 4090022.7093 valve
5980119 0 to 2400 2 m Cable
Plug-in type amplifier with constant currentregulator PDM. Degree of Protection: IP 65.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Mounting: Any position
Type Rated Current Remarks Description(mA)
5980126 0 to 2400 Suitable for 4090020.7093and 4090021.7093 valves
5980127 0 to 1000 Suitable for 4090022.7093 valve
Amplifier module with constant current regulatorPDM. Degree of Protection: IP 20.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Mounting: Any position.For attachment on mounting rail acc. to EN 50022
pQ12
Type Description Specification
0680003 Connector DIN 43650 Form B small
0014400 Silencer M5
Accessories
Data sheet 6.6.030
Data sheet 6.6.031
Type Rated Setpoint Ramps PID-controller for Remarks DescriptionCurrent (mA) Input closed loop contr.
5988020 0 to 2400 0 to ±10 V 4 no Suitable for valves4090XXX, 4088XXX
5988022 0 to 2400 0 to ±10 V 4 yes Suitable for valves4090XXX, 4088XXX
Digital amplifier module with constant currentregulator PDM.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Weight: 0,4 kg
pQ04
Data sheet 7503188
VP40 ND 2
11/99 N/** 6.6.020.03Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
Characteristic curves Flow characteristic for 7 bar operating pressure
6,0
p2 (bar)
(mA)
(mA)
(mA)
p2 = f (W)
5,4
4,8
4,2
3,6
3,0
2,4
1,8
1,2
0,6
0 115 230 345 460 575 690 805
0 150 300 450 600 750 900 1050
1400 15001000 1200800200 400 6000
10
9
8
7
6
5
4
3
2
1
0
16
14
12
10
8
6
4
2
0
p2 (bar)
Q (l/min)
p2 = f (Q) at p1 = 7 bar
6
5
4
3
2
1
0 80 160 240
Flow characteristic for 12 bar operating pressure Flow characteristic for 16 bar operating pressurep2 (bar)
Q (l/min)
p2 = f (Q) at p1 = 16 bar16
14
12
10
8
6
4
2
0 80 160 240 320 400 480
p2 (bar)
Q (l/min)
p2 = f (Q) at p1 = 12 bar10
8
6
4
2
0 80 160 240 320 400
VP40 ND 2
N/** 6.6.020.04 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
General Dimensions, Valve
16
25 36
12,5
19,5
32
75
244
32
4,3
424
M54,
23,8
2 1,1
5
27
1
2
1
2
3
Ø 6
,4 7,5
7,5
14
1 1(3) (3)
2
13Ø 7
,27
G1/8
8M
5
4,3
172432
24
32
M4x6 deep
G1 /
8
10
8
2,5
General Dimensions, Subplate
G 1/8 SubplateType: 0601740 to be ordered separately
Screw plug for open portType: 0568384 to be ordered separately
VP40 ND 2
11/99 N/** 6.6.020.05Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
22222
1(3) 1(3)
C4 C
B
A
16 33
Typ Description Weight (kg)
0601740 Single Subplate Assembly 0,04
0601741 Manifold bar – 2 Valves 0,08
0601742 – 3 Valves 0,13
0601743 – 4 Valves 0,17
0601744 – 5 Valves 0,21
0601745 – 6 Valves 0,24
0559301 Nipple -
0602005 Blind Plate Assembly 0,22
0568384 Screw Plug G 1/8 -
Components
Manifold system
3
2
2
2
2
1
Manifold bar
Blind plate
Nipple
Single subplate
Manifold bar, basic dimensions
Type No. of valves A B C
0601741 2 65 57 -
0601742 3 98 90 -
0601743 4 131 123 -
0601744 5 164 156 57
0601745 6 197 189 57
VP40 ND 2
N/** 6.6.020.06 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
21,5
G1 /
8
1824
26
3
9
7 32
24
32,2
6,5
G1/4
M4
Type Description Weight (kg)
0541070 Stacking plate (without valve) 0,04supplied with 2 brackets and1 O-ring
0657380 Screw plug G 1/4 -
0660835 Sealing ring for 0657380 -
0663083 O-ring -
0541281 Bracket for stacking plates -
Components
Stacking system
3
2
2
2
1
O-ring
Bracket for stacking plate
Stacking plate
Stacking Plate Dimensions
Warning. Bores of mounting bracket must not be used for fastening of stacking system.
64,4
96,6
VP40 ND 2
11/99 N/** 6.6.020.07Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
Type Description Weight (kg)
0543862 Flange assembly 0,1supplied with screw, G 1/8
Components
Flanged System
Flange Assembly Dimensions
2 1
G1 /
8
G1 /
8
20
7
48
8
M4
7
10
9,5
2432 3
14,5 7
24
32
These products are intended for use in industrial compressed air systems only. Do notuse these products where pressures and temperatures can exceed those listed under‘Technical Data’.Before using these products with fluids other than those specified, for non-industrialapplications, life-support systems, or other applications not within publishedspecifications, consult NORGREN.Through misuse, age, or malfunction, components used in fluid power systems canfail in various modes. The system designer is warned to consider the failure modes of
all component parts used in fluid power systems and to provide adequate safeguardsto prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the systeminstructional manual if protection against a failure mode cannot be adequatelyprovided.System designers and end users are cautioned to review specific warnings found ininstruction sheets packed and shipped with these products where applicable.
Warning
VP40 ND 2
N/** 6.6.020.08 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.