vp40 nd 2 textfile/06standardpk.com/en_ds/valves/en_6.6.020.pdf · 2012. 12. 17. · vp40 nd 2 n/**...

8
11/99 N/** 6.6.020.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. VP40 3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis Good repeatability High flow capacity at exhaust port Manifold mountable system Compact design Technical Data Medium: Filtered air, lubricated or unlubricated, Filter 50 μm Operation: Proportional solenoid Connection: Flange, subplate Flow direction: Fixed Operating pressure p 1 : 16 bar max. Pressure setting p 2 : 0 to 16 bar Ambient temperature: -10 to +40 °C Hysteresis: < 3 % (IN, p 2 max) Repeatability: * < 1 % (p 2 max) Linearity: * See characteristic curve Response sensitivity: * 1 % (p 2 max) Degree of protection: IP 65 with connector Mounting: Any position Materials: Body aluminium alloy Seals NBR (Perbunan) *Values referred to 20 °C with dither 20 % IN, 50 Hz Ordering Information 3 way proportional pressure control valve, ND 2, pressure setting 0 to 10 bar, Type: 4090020.7093.012.00 Subplate must be ordered separately. 2 3 1 Connectors See data sheet 7503364 Symbol

Upload: others

Post on 22-Apr-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VP40 ND 2 textfile/06standardpk.com/en_ds/Valves/en_6.6.020.pdf · 2012. 12. 17. · VP40 ND 2 N/** 6.6.020.06 Our policy is one of continued research and development. We therefore

11/99 N/** 6.6.020.01Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

VP40

3 Way Proportional Pressure Control Valve

Nominal diameter 2Direct operated poppet valves

Flange design

Low hysteresis

Good repeatability

High flow capacity at exhaust port

Manifold mountable system

Compact design

Technical DataMedium:

Filtered air, lubricated or unlubricated,Filter 50 µm

Operation:Proportional solenoid

Connection:Flange, subplate

Flow direction:Fixed

Operating pressure p1:16 bar max.

Pressure setting p2:0 to 16 bar

Ambient temperature:-10 to +40 °C

Hysteresis:< 3 % (IN, p2 max)

Repeatability: *< 1 % (p2 max)

Linearity: *See characteristic curve

Response sensitivity: *≤ 1 % (p2 max)

Degree of protection:IP 65 with connector

Mounting:Any position

Materials:Body aluminium alloySeals NBR (Perbunan)

*Values referred to 20 °C with dither 20 % IN, 50 Hz

Ordering Information3 way proportional pressure control valve, ND 2,pressure setting 0 to 10 bar,Type: 4090020.7093.012.00

Subplate must be ordered separately.

2

3 1

ConnectorsSee data sheet 7503364

Symbol

Page 2: VP40 ND 2 textfile/06standardpk.com/en_ds/Valves/en_6.6.020.pdf · 2012. 12. 17. · VP40 ND 2 N/** 6.6.020.06 Our policy is one of continued research and development. We therefore

VP40 ND 2

N/** 6.6.020.02 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

General Information

Type Nominal diameter Connection Pressure Max. Operating Rated Current Drive WeightSetting p2 (bar) Pressure p1 (bar) (mA) Electronics (kg)

4090021.7093.012.00 2 Flange 0 to 6 7 805 pQ11, pQ12, pQ04 0,28

4090020.7093.012.00 2 Flange 0 to 10 12 1050 pQ11, pQ12, pQ04 0,28

4090022.7093.012.00 2 Flange 0 to 16 16 1500 pQ11, pQ12, pQ04 0,28

Voltage 12 V DC

Limiting current IN 1930 mA

Rated power PN 25 W

Resistance R20 6,3 Ω +3%

Duty cycle 100 %

Electrical Information for Proportional Solenoids

Drive ElectronicspQ11

Type Rated Current Electrical connection Remarks Description(mA)

5980083 0 to 1000 Connector acc. to DIN 43651 Suitable for 4090020.70935980087 0 to 1000 2 m Cable and 4090021.7093 valves

5980118 0 to 2400 Connector acc. to DIN 43651 Suitable for 4090022.7093 valve

5980119 0 to 2400 2 m Cable

Plug-in type amplifier with constant currentregulator PDM. Degree of Protection: IP 65.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Mounting: Any position

Type Rated Current Remarks Description(mA)

5980126 0 to 2400 Suitable for 4090020.7093and 4090021.7093 valves

5980127 0 to 1000 Suitable for 4090022.7093 valve

Amplifier module with constant current regulatorPDM. Degree of Protection: IP 20.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Mounting: Any position.For attachment on mounting rail acc. to EN 50022

pQ12

Type Description Specification

0680003 Connector DIN 43650 Form B small

0014400 Silencer M5

Accessories

Data sheet 6.6.030

Data sheet 6.6.031

Type Rated Setpoint Ramps PID-controller for Remarks DescriptionCurrent (mA) Input closed loop contr.

5988020 0 to 2400 0 to ±10 V 4 no Suitable for valves4090XXX, 4088XXX

5988022 0 to 2400 0 to ±10 V 4 yes Suitable for valves4090XXX, 4088XXX

Digital amplifier module with constant currentregulator PDM.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Weight: 0,4 kg

pQ04

Data sheet 7503188

Page 3: VP40 ND 2 textfile/06standardpk.com/en_ds/Valves/en_6.6.020.pdf · 2012. 12. 17. · VP40 ND 2 N/** 6.6.020.06 Our policy is one of continued research and development. We therefore

VP40 ND 2

11/99 N/** 6.6.020.03Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

Characteristic curves Flow characteristic for 7 bar operating pressure

6,0

p2 (bar)

(mA)

(mA)

(mA)

p2 = f (W)

5,4

4,8

4,2

3,6

3,0

2,4

1,8

1,2

0,6

0 115 230 345 460 575 690 805

0 150 300 450 600 750 900 1050

1400 15001000 1200800200 400 6000

10

9

8

7

6

5

4

3

2

1

0

16

14

12

10

8

6

4

2

0

p2 (bar)

Q (l/min)

p2 = f (Q) at p1 = 7 bar

6

5

4

3

2

1

0 80 160 240

Flow characteristic for 12 bar operating pressure Flow characteristic for 16 bar operating pressurep2 (bar)

Q (l/min)

p2 = f (Q) at p1 = 16 bar16

14

12

10

8

6

4

2

0 80 160 240 320 400 480

p2 (bar)

Q (l/min)

p2 = f (Q) at p1 = 12 bar10

8

6

4

2

0 80 160 240 320 400

Page 4: VP40 ND 2 textfile/06standardpk.com/en_ds/Valves/en_6.6.020.pdf · 2012. 12. 17. · VP40 ND 2 N/** 6.6.020.06 Our policy is one of continued research and development. We therefore

VP40 ND 2

N/** 6.6.020.04 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

General Dimensions, Valve

16

25 36

12,5

19,5

32

75

244

32

4,3

424

M54,

23,8

2 1,1

5

27

1

2

1

2

3

Ø 6

,4 7,5

7,5

14

1 1(3) (3)

2

13Ø 7

,27

G1/8

8M

5

4,3

172432

24

32

M4x6 deep

G1 /

8

10

8

2,5

General Dimensions, Subplate

G 1/8 SubplateType: 0601740 to be ordered separately

Screw plug for open portType: 0568384 to be ordered separately

Page 5: VP40 ND 2 textfile/06standardpk.com/en_ds/Valves/en_6.6.020.pdf · 2012. 12. 17. · VP40 ND 2 N/** 6.6.020.06 Our policy is one of continued research and development. We therefore

VP40 ND 2

11/99 N/** 6.6.020.05Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

22222

1(3) 1(3)

C4 C

B

A

16 33

Typ Description Weight (kg)

0601740 Single Subplate Assembly 0,04

0601741 Manifold bar – 2 Valves 0,08

0601742 – 3 Valves 0,13

0601743 – 4 Valves 0,17

0601744 – 5 Valves 0,21

0601745 – 6 Valves 0,24

0559301 Nipple -

0602005 Blind Plate Assembly 0,22

0568384 Screw Plug G 1/8 -

Components

Manifold system

3

2

2

2

2

1

Manifold bar

Blind plate

Nipple

Single subplate

Manifold bar, basic dimensions

Type No. of valves A B C

0601741 2 65 57 -

0601742 3 98 90 -

0601743 4 131 123 -

0601744 5 164 156 57

0601745 6 197 189 57

Page 6: VP40 ND 2 textfile/06standardpk.com/en_ds/Valves/en_6.6.020.pdf · 2012. 12. 17. · VP40 ND 2 N/** 6.6.020.06 Our policy is one of continued research and development. We therefore

VP40 ND 2

N/** 6.6.020.06 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

21,5

G1 /

8

1824

26

3

9

7 32

24

32,2

6,5

G1/4

M4

Type Description Weight (kg)

0541070 Stacking plate (without valve) 0,04supplied with 2 brackets and1 O-ring

0657380 Screw plug G 1/4 -

0660835 Sealing ring for 0657380 -

0663083 O-ring -

0541281 Bracket for stacking plates -

Components

Stacking system

3

2

2

2

1

O-ring

Bracket for stacking plate

Stacking plate

Stacking Plate Dimensions

Warning. Bores of mounting bracket must not be used for fastening of stacking system.

64,4

96,6

Page 7: VP40 ND 2 textfile/06standardpk.com/en_ds/Valves/en_6.6.020.pdf · 2012. 12. 17. · VP40 ND 2 N/** 6.6.020.06 Our policy is one of continued research and development. We therefore

VP40 ND 2

11/99 N/** 6.6.020.07Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

Type Description Weight (kg)

0543862 Flange assembly 0,1supplied with screw, G 1/8

Components

Flanged System

Flange Assembly Dimensions

2 1

G1 /

8

G1 /

8

20

7

48

8

M4

7

10

9,5

2432 3

14,5 7

24

32

These products are intended for use in industrial compressed air systems only. Do notuse these products where pressures and temperatures can exceed those listed under‘Technical Data’.Before using these products with fluids other than those specified, for non-industrialapplications, life-support systems, or other applications not within publishedspecifications, consult NORGREN.Through misuse, age, or malfunction, components used in fluid power systems canfail in various modes. The system designer is warned to consider the failure modes of

all component parts used in fluid power systems and to provide adequate safeguardsto prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the systeminstructional manual if protection against a failure mode cannot be adequatelyprovided.System designers and end users are cautioned to review specific warnings found ininstruction sheets packed and shipped with these products where applicable.

Warning

Page 8: VP40 ND 2 textfile/06standardpk.com/en_ds/Valves/en_6.6.020.pdf · 2012. 12. 17. · VP40 ND 2 N/** 6.6.020.06 Our policy is one of continued research and development. We therefore

VP40 ND 2