voorblad. afbeelding aan te leveren door marketing. tekst
TRANSCRIPT
Voorblad. Afbeelding aan te leveren door Marketing. Tekst voor afbeelding plaatsen “productname”. Let op dat de versie overeenkomt met het revisienummer uit EPDM (voettekst document)
ID:
020624
Revision: 10-01 1
© Avantes BV www.avantes.com [email protected]
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, by any means, electronic, mechanical, photocopying, recording, or otherwise, without
written permission from Avantes bv. This manual is sold as part of an order and subject to the condition that it shall not, by way of trade
or otherwise, be lent, re-sold, hired out or otherwise circulated without the prior consent of Avantes bv in any form of binding or cover other than that in which it is published.
Every effort has been made to make this manual as complete and as accurate as possible, but no warranty or fitness is implied. The information provided is on an “as is” basis. Avantes bv shall have neither liability nor responsibility to any person or entity with respect to any loss or damages arising
from the information contained in this manual.
ID:
020624
Revision: 10-01 2
© Avantes BV www.avantes.com [email protected]
Table of Content
1 Introduction ................................................................................................... 3
2 Quick Start .................................................................................................... 5
2.1 Installing the AvaSpec Software ...................................................................... 5
2.2 Launching the Software ............................................................................... 7
2.3 Quick Start: Measuring and saving a spectrum ..................................................... 8
2.4 Measurement Setups ................................................................................... 9
3 Miniature Fiber Optic Spectrometers ..................................................................... 11
3.1 AvaSpec-RS (Replaceable-Slit)....................................................................... 11
3.2 Spectrometer connections USB3.0/Ethernet platform ........................................... 12
3.2.1 StarLine AvaSpec-ULS……-EVO ................................................................. 12
3.2.2 SensLine AvaSpec-ULS……-EVO................................................................. 13
3.2.3 SensLine AvaSpec-HS2048XL-EVO ............................................................. 14
3.2.4 SensLine AvaSpec-ULS2048x64TEC-EVO ...................................................... 15
3.2.5 SensLine AvaSpec-HSC1024x58TEC-EVO ...................................................... 16
3.2.6 NIRLine AvaSpec-NIR256/512-1.7-EVO ....................................................... 17
3.2.7 NIRLine AvaSpec-NIR256/512-……-HSC-EVO .................................................. 18
3.2.8 AvaSpec LED indicators and I/O connectors ................................................. 19
3.3 Spectrometer connections USB2 platform ......................................................... 22
3.3.1 CompactLine AvaSpec-Mini MK-II series ...................................................... 22
3.3.2 StarLine AvaSpec-ULS…….-USB2 ............................................................... 24
3.3.3 SensLine AvaSpec-ULS2048x16-USB2 ......................................................... 25
3.3.4 SensLine AvaSpec-ULS2048L-TEC-USB2 ....................................................... 26
3.3.5 Dual Channel AvaSpec-USB2 ................................................................... 27
3.3.6 Multichannel connections USB2 platform .................................................... 28
3.3.7 AvaSpec-UV/VIS/NIR ............................................................................ 30
3.3.8 AvaSpec LED indicators and I/O connectors ................................................. 31
4 AvaSoft manual .............................................................................................. 33
ID:
020624
Revision: 10-01 3
© Avantes BV www.avantes.com [email protected]
1 Introduction
Thank you for purchasing an AvaSpec Avantes Fiber Optic Spectrometer System. The latest version of this manual can also be downloaded from our website www.avantes.com under the section downloads. This manual provides users with directions for configuring your AvaSpec with your computer and operating of the AvaSpec:
AvaSpec CompactLine
MK-II series: AvaSpec-Mini2048CL AvaSpec-Mini4096CL AvaSpec-Mini-NIR256-1.7
AvaSpec StarLine AvaSpec SensLine AvaSpec NIRLine
AvaSpec-ULS2048(L)-USB2 AvaSpec-ULS3648-USB2 AvaSpec-FAST series AvaSpec-ULS2048L-EVO AvaSpec-ULS2048CL-EVO AvaSpec-ULS4096CL-EVO
AvaSpec-ULS2048x16-USB2 AvaSpec-ULS2048LTEC-USB2 AvaSpec-ULS2048XL-EVO AvaSpec-ULS2048x64-EVO AvaSpec-HS2048XL-EVO AvaSpec-ULS2048x64TEC-EVO AvaSpec-HSC1024x58TEC-EVO
AvaSpec-NIR256/512-1.7-EVO AvaSpec-NIR256/512-1.7 HSC-EVO AvaSpec-NIR256/512-2.5-HSC-EVO
For abbreviated directions on setting up your system, turn to the instructions beginning in chapter 2: Quick Start. This manual describes the installation and operation for USB2.0 and USB3.0/Ethernet platform spectrometers. If applicable, separate manuals are available and supplied with the light sources, fiber optics and accessories. There is a separate manual for AvaSoft version Spectrometer Software as a PDF document which can be downloaded from the Avantes website. A separate manual is available for OEM customers. Contents of shipment In your shipment box you will find the following, please check carefully if all items are present:
• AvaSpec spectrometer • Wavelength Calibration Data Sheet • USB cable
AvaSpec Spectrometer All electrical connectors are located on the backside; on the front side the optical entrance connector can be found. On the bottom or backside, a label is located with spectrometer type, serial number, installation options, date and the customer’s name. Please follow instructions in chapter 1 or 2 for installation. Power Supply PS-12VDC/2.08A (optional for SPU-2 and StarLine/SensLine EVO) The PS-12V/2.08A power supply is standard equipped with a CEE 7/16 Euro plug connector and is suitable for 100-240 VAC. If you need different socket connection, please contact us for the US, UK or Australian power supply. Please follow instructions in chapter 3 before connecting the power supply.
ID:
020624
Revision: 10-01 4
© Avantes BV www.avantes.com [email protected]
PS-12VDC/5.0A for HSC NIRLine and SensLine TEC-EVO The PS-12V/5.0A power supply is standard equipped with a CEE 7/16 Euro plug connector and is suitable for 100-240 VAC. If you need different socket connection, please contact us for the US, UK or Australian power supply. Please follow instructions in chapter 3 before connecting the power supply.
Interface Cables The standard USB interface cable is included in the shipment. EVO systems are shipped with a USB3.0 cable. For connection to an RS-232 interface, an IC-DB26/DB9-2 is needed, the cable should be ordered separately with the instrument. Ethernet cable is not included in standard delivery.
Wavelength Calibration Data Sheet This calibration sheet is unique to your spectrometer; it includes the wavelength calibration coefficients, installed grating, wavelength range and options as well as the spectrometer serial number. Please make sure to save this document in a secure place.
Upgrades Sometimes an upgrade or a change to your system is desired. For Avantes to make these changes, the customer should first contact us and obtain a Return to Manufacturer Authorization (RMA) number. Please contact Avantes Technical Services for specific instructions when returning a product. You can send an email to [email protected]
If you have problems with your installation, please do not hesitate to contact us:
Avantes Technical Support Oude Apeldoornseweg 28
NL-7333 NS Apeldoorn The Netherlands
Tel. +31-(0) 313-670170, Fax. +31-(0) 313-670179 www.avantes.com [email protected]
ID:
020624
Revision: 10-01 5
© Avantes BV www.avantes.com [email protected]
2 Quick Start
Before you connect the AvaSpec spectrometer to the USB port of your computer, you need to install the AvaSoft software first. AVASOFT version 8 is a 32-bit application that can be installed under the following operating systems: • 32 bit Windows 7/Windows 8/Windows 10 • 64 bit Windows 7/Windows 8/Windows 10
2.1 Installing the AvaSpec Software Browse to www.avantes.com/gettingstarted and download the Quick Start Guide and latest software. Registration is required. Installation Dialogs The setup program will check the system configuration of the computer. If no problems are detected, the first dialog is the “Welcome” dialog with some general information. In the next dialog, the destination directory for the AvaSoft software can be changed. The default destination directory is C:\Program Files (x86)\AvaSoft8. If you want to install the software to a different directory, click the Browse button, select a new directory and click OK. If the specified directory does not exist, it will be created.
After this, the “Start Installation” dialog is shown. After clicking the “Next” button, the installation program starts installing files. During the installation, the install program will check if the WinUSB driver has been installed on the PC. In some earlier AvaSoft versions, an Avantes kernel USB driver was installed for AS5216 spectrometers on 32bit versions of Windows.
ID:
020624
Revision: 10-01 6
© Avantes BV www.avantes.com [email protected]
The Device Driver Installation Wizard will be launched automatically. The last dialog in the Device Driver Installation Wizard displays whether the WinUSB driver has been installed correctly.
After all files have been installed, the “Installation Complete” dialog shows up. Click Finish. Connecting the hardware Connect the USB connector to a USB port on your computer with the supplied USB cable (this can be USB2.0 or USB3.0), wait until the green LED is ON before you start AvaSoft. USB with external power supply Connect power supply to spectrometer, then connect the USB cable between the spectrometer and computer, wait until the green LED is ON, then start AvaSoft. Note: USB3.0 speed requires USB3.0 cable and USB3.0 port on the computer. Ethernet with external power supply (only applicable for EVO spectrometers) Connect the power supply to the spectrometer and connect the Ethernet cable between the spectrometer and LAN. Default a new spectrometer is delivered with DHCP enabled. The green LED is blinking during request of the IP address, when the green LED remains ON, the spectrometer is ready for use.
ID:
020624
Revision: 10-01 7
© Avantes BV www.avantes.com [email protected]
2.2 Launching the Software AvaSoft can be started in the Windows Start Menu. Under ‘Start’, ‘All Programs’, a group “AVANTES Software” has been added, which has an entry for the AvaSoft 8 program and an entry for the AvaSoft 8 help file. There will also be an AvaSoft 8 icon on the desktop that you can click. After starting the AvaSoft 8 software, a welcome window will be displayed that will show the spectrometers that are connected. The AvaSoft 8 windows will be displayed next. Refer to section 3 for a description of the different windows. A “Quick Start” can be found in the section below, if you want to start measuring immediately. Detailed information about the menu options can be found in the separate AvaSoft manual. Depending on the AvaSoft version (Basic or Full) and the extra add-on modules that were ordered for your spectrometer, more applications are available in AvaSoft Full, which are described in the separate AvaSoft manual:
• Wavelength Calibration (needs AvaSoft Full) • Time Series (works in AvaSoft Basic) • Process Control (included in Time Series) • Excel Output (works in AvaSoft Basic) • Chemometry (needs AvaSoft Full & CHEM) • Color Measurement (needs AvaSoft Full & COL)) • Irradiance Measurement (needs AvaSoft Full & IRRAD) • Raman (needs extra hardware) • Thin Film (needs AvaSoft Full)
Start AvaSoft with Ethernet spectrometers. At the startup, AvaSoft searches only for USB devices by default. To use Ethernet, settings in ‘options’ menu of AvaSoft have to be changed, see AvaSoft manual. If no DHCP server is available in your network, you can change the IP settings of spectrometer to fixed IP. Please use the IP_Settings_AS7010 utility. This utility can be found in the Avantes software folder in the Windows start menu.
ID:
020624
Revision: 10-01 8
© Avantes BV www.avantes.com [email protected]
2.3 Quick Start: Measuring and saving a spectrum 1. After starting AvaSoft, the Start button in the upper left corner of the screen needs to be
clicked to start measuring. 2. Connect a fiber or probe to the light source and to the spectrometer input port(s) and set up
the experiment for taking a reference spectrum. 3. Optimal smoothing is preset and stored on board in the EEPROM. 4. Now turn on the light source. Usually some sort of spectrum may be seen on the screen, but it
is possible that too much or too little light reaches the spectrometer with the present data collection settings. Too much light means that, over a certain wavelength range, the signal is saturated; this is shown as a straight line at the maximum counts and the appearance of the label “saturated” in the spectrometer window of the channel. This can usually be solved by a shorter integration time. The integration time can be changed in the spectrometer window (by pressing the cogwheel icon, by directly changing the ms value, or by pressing the Auto-configure Integration time button. Try to adjust the integration time, such that the maximum count over the wavelength range is around 90% of the full ADC scale (59000 counts for a 16bit ADC). When at minimum integration time the signal is still too high, an attenuator, a neutral density filter or fibers with a smaller diameter may be used. When not enough light reaches the spectrometer, likewise a longer integration time should be entered.
5. When a good spectrum is displayed, turn off the light source. 6. Now save the Dark data. This can be done by clicking the dark bulb icon in the spectrometer
window, or the one on the left top of the screen with the mouse. Always use Save Dark after the integration time has been changed.
7. Turn on the light source again. Save the present spectrum as a reference by clicking the bright bulb icon (next to the dark one). Always use Save Reference after the integration time has been changed. Now the measure mode can be changed to e.g. Absorbance (A button) or Transmittance (T button). To have a better look at the amplitude versus wavelength, the Assign Cursor button can be clicked in the Tools menu. A vertical line is then displayed in the graph. If the mouse cursor is placed nearby this line, the shape of the mouse cursor changes from an arrow to a ‘splitter’ shape. If this shape is displayed, the left mouse button can be used to drag (keep left mouse button down) the line with the mouse towards a new position. Moving this line shows the corresponding values of wavelength and amplitude in the status line of the screen. By clicking the stop button, the data acquisition is stopped and the last acquired spectrum is shown in static mode. The data acquisition can be started again by clicking the same button, which now displays ‘Start’.
8. To save the spectrum (in the mode chosen before), choose ‘File’-‘Save’ from the menu. 9. To improve the Signal/Noise ratio, a number of spectra may be averaged. To do this, the value
in the spectrometer window (below the integration time) can be increased. The new value will take effect when you press the ‘Set’ button.
ID:
020624
Revision: 10-01 9
© Avantes BV www.avantes.com [email protected]
2.4 Measurement Setups On the following pages the typical configurations for absorbance, transmission, irradiance, and reflection experiments can be found. UV/VIS Absorbance/Transmission Setup
Irradiance Setup
ID:
020624
Revision: 10-01 10
© Avantes BV www.avantes.com [email protected]
Reflection Setup
Fluorescence Setup
ID:
020624
Revision: 10-01 11
© Avantes BV www.avantes.com [email protected]
3 Miniature Fiber Optic Spectrometers
The technical specifications and product information, on the separate spectrometer products, can be found in the latest Avantes Catalog as well as on our website. In the following paragraphs specific product information regarding interface signals, pin-outs, etc. is given for the different platforms.
3.1 AvaSpec-RS (Replaceable-Slit)
For most customers the choice between throughput and resolution is not an easy one. Avantes offers the possibility for end-users to easily replace a slit through the introduction of our replaceable-slit feature. The replaceable slit option is available for the following spectrometers:
AvaSpec StarLine AvaSpec SensLine AvaSpec NIRLine
AvaSpec-ULS2048(L)-USB2 AvaSpec-ULS3648-USB2 AvaSpec-ULS2048L-EVO AvaSpec-ULS2048CL-EVO AvaSpec-ULS4096CL-EVO
AvaSpec-ULS2048x16-USB2 AvaSpec-ULS2048LTEC-USB2 AvaSpec-ULS2048XL-EVO AvaSpec-ULS2048x64-EVO AvaSpec-ULS2048x64TEC-EVO AvaSpec-HSC1024x58TEC-EVO
AvaSpec-NIR256/512-1.7-EVO AvaSpec-NIR256/512-1.7-HSC-EVO AvaSpec-NIR256/512-2.5-HSC-EVO
Slit Kit To fully utilize your AvaSpec-RS series spectrometer with replaceable slit, the Slit Kit is available. It features a complete set with four slits, of 25, 50, 100, 200 and 500 μm (any combination possible). Also included in the kit are the tools to easily change the slit in the spectrometer. The Slit Kit is available in SMA and FC/PC versions. Both kits can be used on any spectrometer with the replaceable slit option installed. No recalibration of the spectrometer is needed when changing slit because of the high-precision slit positioning.
SMA-RS entrance
ID:
020624
Revision: 10-01 12
© Avantes BV www.avantes.com [email protected]
3.2 Spectrometer connections USB3.0/Ethernet platform
3.2.1 StarLine AvaSpec-ULS……-EVO
Specifications of connections and LEDs see section: 3.2.8 AvaSpec LED indicators and I/O connectors. Power connector (only needed if not USB-powered or Ethernet operation) The power connector is a Low power DC connector with GND on outer contact and +12VDC typical on inner contact. The outside diameter is 5.5mm, the inside diameter is 2.1mm. The electrical circuit accepts voltages between 5 and 15V. Note: Please use Avantes PS-12VDC/2.08A power supply or 12VDC battery pack only. Serious
damage to the electronics may occur, when other power supplies with different polarity and/or Voltage ratings are used.
Power LED Green
SMA entrance
Scan LED Yellow
External IO
26 pole
Synchronization connector
USB 3.0 Connector
Ethernet connector
Power connector
ID:
020624
Revision: 10-01 13
© Avantes BV www.avantes.com [email protected]
3.2.2 SensLine AvaSpec-ULS……-EVO
Specifications of connections and LEDs see section: 3.2.8 AvaSpec LED indicators and I/O connectors. USB-powered When the AvaSpec-ULS2048XL-EVO gets USB-powered it will only starts-up when connected to an USB3.0 port. When powered from an USB2.0 port the spectrometer will not start-up due to the lower available current with USB2.0. Note: Please use Avantes IC-USB3-2 cables, to guarantee the working at USB power.
When other USB cables are used the working is not guaranteed. Power connector (only needed if not USB-powered or Ethernet operation) The power connector is a Low power DC connector with GND on outer contact and +12VDC typical on inner contact. The outside diameter is 5.5mm, the inside diameter is 2.1mm. The electrical circuit accepts voltages between 5 and 15V. Note: Please use Avantes PS-12VDC/2.08A power supply or 12VDC battery pack only. Serious
damage to the electronics may occur, when other power supplies with different polarity and/or Voltage ratings are used.
Power LED Green
SMA entrance
Scan LED Yellow
External IO
26 pole
Synchronization connector
USB 3.0 Connector
Ethernet connector
Power connector
ID:
020624
Revision: 10-01 14
© Avantes BV www.avantes.com [email protected]
3.2.3 SensLine AvaSpec-HS2048XL-EVO
Specifications of connections and LEDs see section: 3.2.8 AvaSpec LED indicators and I/O connectors. USB-powered When the AvaSpec-HS2048XL-EVO gets USB-powered it will only starts-up when connected to an USB3.0 port. When powered from an USB2.0 port the spectrometer will not start-up due to the lower available current with USB2.0. Note: Please use Avantes IC-USB3-2 cables, to guarantee the working at USB power.
When other USB cables are used the working is not guaranteed. Power connector (only needed if not USB-powered or Ethernet operation) The power connector is a Low power DC connector with GND on outer contact and +12VDC typical on inner contact. The outside diameter is 5.5mm, the inside diameter is 2.1mm. The electrical circuit accepts voltages between 5 and 15V. Note: Please use Avantes PS-12VDC/2.08A power supply or 12VDC battery pack only. Serious
damage to the electronics may occur, when other power supplies with different polarity and/or Voltage ratings are used.
Power LED Green
SMA entrance
Scan LED Yellow
External IO
26 pole
Synchronization connector
USB 3.0 Connector
Ethernet connector
Power connector
ID:
020624
Revision: 10-01 15
© Avantes BV www.avantes.com [email protected]
3.2.4 SensLine AvaSpec-ULS2048x64TEC-EVO
Specifications of connections and LEDs see section: 3.2.8 AvaSpec LED indicators and I/O connectors. 12VDC Power connector The power connector is a 4pins power DC connector with GND and +12V contacts. Note: Please use Avantes PS-12VDC/5.0A power supply only.
The power supply is supplied as standard with the AvaSpec NIRLine. Serious damage to the electronics may occur, when other power supplies with different polarity and/or Voltage ratings are used.
Scan LED Yellow
Synchronization connector
12VDC Power connector
SMA entrance
Ethernet connector
External IO 26 pole
USB 3.0 connector
Power LED Green
ID:
020624
Revision: 10-01 16
© Avantes BV www.avantes.com [email protected]
3.2.5 SensLine AvaSpec-HSC1024x58TEC-EVO
Specifications of connections and LEDs see section: 3.2.8 AvaSpec LED indicators and I/O connectors. 12VDC Power connector The power connector is a 4pins power DC connector with GND and +12V contacts. Note: Please use Avantes PS-12VDC/5.0A power supply only.
The power supply is supplied as standard with the AvaSpec NIRLine. Serious damage to the electronics may occur, when other power supplies with different polarity and/or Voltage ratings are used.
Scan LED Yellow
Synchronization connector
12VDC Power connector
SMA entrance
Ethernet connector
External IO 26 pole
USB 3.0 connector
Power LED Green
ID:
020624
Revision: 10-01 17
© Avantes BV www.avantes.com [email protected]
3.2.6 NIRLine AvaSpec-NIR256/512-1.7-EVO
Specifications of connections and LEDs see section: 3.2.8 AvaSpec LED indicators and I/O connectors. USB-powered When the AvaSpec-NIR256/512-1.7-EVO gets USB-powered it will only starts-up when connected to an USB3.0 port. When powered from an USB2.0 port the spectrometer will not start-up due to the lower available current with USB2.0. Note: Please use Avantes IC-USB3-2 cables, to guarantee the working at USB power.
When other USB cables are used the working is not guaranteed. Power connector (only needed if not USB-powered or Ethernet operation) The power connector is a Low power DC connector with GND on outer contact and +12VDC typical on inner contact. The outside diameter is 5.5mm, the inside diameter is 2.1mm. The electrical circuit accepts voltages between 5 and 15V. Note: Please use Avantes PS-12VDC/2.08A power supply or 12VDC battery pack only. Serious
damage to the electronics may occur, when other power supplies with different polarity and/or Voltage ratings are used.
Scan LED Yellow
Synchronization connector
12VDC Power connector
SMA entrance
Ethernet connector
External IO 26 pole
USB 3.0 connector
Power LED Green
ID:
020624
Revision: 10-01 18
© Avantes BV www.avantes.com [email protected]
3.2.7 NIRLine AvaSpec-NIR256/512-……-HSC-EVO
Specifications of connections and LEDs see section: 3.2.8 AvaSpec LED indicators and I/O connectors. 12VDC Power connector The power connector is a 4pins power DC connector with GND and +12V contacts. Note: Please use Avantes PS-12VDC/5.0A power supply only.
The power supply is supplied as standard with the AvaSpec NIRLine. Serious damage to the electronics may occur, when other power supplies with different polarity and/or Voltage ratings are used.
Scan LED Yellow
Synchronization connector
12VDC Power connector
SMA entrance
Ethernet connector
External IO 26 pole
USB 3.0 connector
Power LED Green
ID:
020624
Revision: 10-01 19
© Avantes BV www.avantes.com [email protected]
3.2.8 AvaSpec LED indicators and I/O connectors
Power LED green and scan LED yellow The green and yellow LEDs act as status LEDs for the spectrometer with following meaning:
Connection USB Ethernet
DHCP
Ethernet
Fixed IP
Green LED = off No power No power No power
Green LED = on Power is on,
spectrometer ready
Power is on
spectrometer ready
Power is on
spectrometer ready
Green LED = blinking
fast
Error detected by spectrometer
Error detected by spectrometer
Error detected by spectrometer
Green LED = blinking
Slow (1Hz)
N/A Requesting IP address N/A
Yellow LED = on scanning in progress scanning in progress scanning in progress
USB 3.0 connector The USB interface has the following physical characteristics:
• USB version 3.0 • Super Speed, 4.8 Gbit/s • endpoint node, no HUB function • 5VDC power supply
Note: Please use Avantes IC-USB3-2 cables, to guarantee the working at USB power.
When other USB cables are used the working is not guaranteed. Ethernet Connector RJ45 The RJ45 connector has the following physical characteristics:
• Gigabit Ethernet • 1 Gbit/s • TCP/IP protocol
Synchronization connector SMB miniature 50R coax synchronization connector, to synchronize to other AvaSpec-EVO (or USB2) spectrometers only, order code for SMA cables is IC-COAX-SMB-0,25 for 250mm coax cable (included in dual channel spectrometers)
ID:
020624
Revision: 10-01 20
© Avantes BV www.avantes.com [email protected]
External IO 26 pole The external I/O connector is a female high density 26 poles Sub-D connector.
Pin Name Connect to Comment
1 GND GND (DB15-p10 or DB9-p1)
2 DO2 Disable (DB15-p11) general purpose TTL output, max 25 mA*, or used to disable the AvaLight-HAL-(S)-Mini
3 DO5 BSC-DA (Binder768-p1) general purpose TTL output, PWM, max 25 mA*, or used to control the BSC-DA
4 DO8 FOS (DB15-p15)
BSC-DA (Binder768-p3)
general purpose TTL output, max 25 mA*, or used to control the FOS or BSC-DA
5 STROBE AVALIGHT-XE (DB15-p1) Output, one or more TTL pulses per scan, max 50 mA*
6 Trig In External trigger TTL Input, external hardware trigger
7 DI2 TTL input, AvaSoft-Save spectrum
8 GND GND
9 AI1 Analog input, 0-5VDC
10 Reserved
11 DO1 AvaLight-LED (DB15-p2) general purpose TTL output, PWM, AvaSoft-PWM, max 25 mA*
12 DO4 Shutter(DB15-p13) general purpose TTL output , max 25 mA*, or used to close shutter for AvaLight-HAL-S-Mini, AvaLight-DHc and AvaLight-DHS
13 DO7 general purpose TTL output, PWM, max 25 mA*
14 GND GND
15 5VDC DB15-p3 5VDC output, max 25 mA*
16 DI3 TTL input, AvaSoft-Save reference
17 AO1 Analog output, 0-5VDC
18 AI2 Analog input, 0-5VDC
19 Reserved
20 DO3 general purpose TTL output, PWM, max 25 mA*
21 DO6 Long life general purpose TTL output , max 25 mA*, or used for long life mode of the AvaLight-HAL-(S)-Mini
22 DO9 High power general purpose TTL output , max 25 mA*, or used for high power mode of the AvaLight-HAL-(S)-Mini
23 LASER OUT
LASER TTL for LIBS TTL output, AvaSoft programmable delay and duration, max 50 mA*
24 DI1 TTL input, AvaSoft-Save dark
25 DO10 general purpose TTL output, max 25 mA*
26 AO2 Analog output, 0-5VDC
* All DO’s combined cannot supply more than 150 mA
ID:
020624
Revision: 10-01 21
© Avantes BV www.avantes.com [email protected]
Ordering Information Interface cables IC-DB26-2 Interface cable AvaSpec for all Avantes light sources with a DB15
connector IC-DB26-FOS2-2 Interface Y-cable AvaSpec to FOS-2 and all Avantes light sources with a
DB15 connector IC-USB3-2 Interface cable AvaSpec to USB3.0 port on PC, 2m IC-Extrig-USB2 Interface cable AvaSpec to External trigger pushbutton, 2m IC-DB26-Extrig-USB2 Interface Y-cable AvaSpec to External trigger pushbutton and all Avantes
light sources with a DB15 connector IC-DB26-EXTRIG-BNC-2 Interface cable AvaSpec platform to BNC plug External trigger, 2 m IC-COAX-SMB-0.25 Synchronization coax cable with 2 SMB connectors 0.25m for AvaSpec IC-DB26-BEAM-2 Interface cable AvaSpec to BSC-DA, 2m
ID:
020624
Revision: 10-01 22
© Avantes BV www.avantes.com [email protected]
3.3 Spectrometer connections USB2 platform
3.3.1 CompactLine AvaSpec-Mini MK-II series
Models: o AvaSpec-Mini2048CL-xxx o AvaSpec-Mini4096CL-xxx o AvaSpec-Mini-NIR256-1.7
Power LED green and scan LED yellow The green and yellow LEDs act as status LEDs for the spectrometer with following meaning:
connection USB
Green LED = off No power
Green LED = on Power is on,
spectrometer ready
Green LED = blinking Error detected by spectrometer
Yellow LED = on scanning in progress
USB-A cable connector The USB interface has the following physical characteristics:
• USB version 2.0 • high speed, 480 Mbit/s • endpoint node, no HUB function • fixed cable length 50 cm
SMA entrance Scan LED Yellow
Power LED Green
USB-A connector
External I/O Würth WTB10
ID:
020624
Revision: 10-01 23
© Avantes BV www.avantes.com [email protected]
External I/O Würth WTB 10
Pin Name Connect to Comment
1 DIO1 External trigger General purpose TTL input/output , max 25 mA*, or external hardware trigger, or AvaSoft Save Dark
2 DIO2 General purpose TTL input/output , max 25 mA*, or synchronization with another spectrometer, or
AvaSoft Save Spectrum
3 DIO3 General purpose TTL input/output , max 25 mA*, or AvaSoft Save Reference
4 DIO4 Shutter (DB15-p2) General purpose TTL input/output , max 25 mA*, or used to close shutter for AvaLight-HAL-S-Mini,
AvaLight-DHc and AvaLight-DHS when selected in AvaSoft
5 DIO5 AVALIGHT-XE (DB15-p1) General purpose TTL input/output , max 25 mA*, or strobe control for one or more TTL pulses per scan
6 5VDC DB15-p3 5VDC output, max 25 mA*
7 GND GND
8 AI1 Analog Input, 0 – 5VDC
9 AO1 Analog output, 0 – 5VDC
10 GND GND
* All DIO combined cannot supply more than 150 mA
Note: The Digital IO can only support one function at the time.
ID:
020624
Revision: 10-01 24
© Avantes BV www.avantes.com [email protected]
3.3.2 StarLine AvaSpec-ULS…….-USB2
Specifications of connections and LEDs see section: 3.3.8 AvaSpec LED indicators and I/O connectors. Power connector (only needed if not USB-powered) The power connector is a Low power DC connector with GND on outer contact and +12VDC typical on inner contact. The outside diameter is 5.5mm, the inside diameter is 2.1mm. The electrical circuit accepts voltages between 5 and 15V. Note: Please use Avantes PS-12VDC/2.08A power supply only. Serious damage to the electronics
may occur, when other power supplies with different polarity and/or Voltage ratings are used.
Scan LED Yellow
SMA entrance
Power LED Green
External IO 26 pole
Synchronization connector
Power connector
USB2 connector
ID:
020624
Revision: 10-01 25
© Avantes BV www.avantes.com [email protected]
3.3.3 SensLine AvaSpec-ULS2048x16-USB2
Specifications of connections and LEDs see section: 3.3.8 AvaSpec LED indicators and I/O connectors. Power connector (only needed if not USB-powered) The power connector is a Low power DC connector with GND on outer contact and +12VDC typical on inner contact. The outside diameter is 5.5mm, the inside diameter is 2.1mm. The electrical circuit accepts voltages between 5 and 15V. Note: Please use Avantes PS-12VDC/2.08A power supply only. Serious damage to the electronics
may occur, when other power supplies with different polarity and/or Voltage ratings are used.
SMA entrance
Scan LED Yellow
Power LED Green
USB2 connector
External IO 26 pole
Power connector
Synchronization connector
ID:
020624
Revision: 10-01 26
© Avantes BV www.avantes.com [email protected]
3.3.4 SensLine AvaSpec-ULS2048L-TEC-USB2
Specifications of connections and LEDs see section: 3.3.8 AvaSpec LED indicators and I/O connectors. Power connector with double Fuse and switch The power connector for 100-240 VAC is located on the rear of the AvaSpec. Be careful to use it with a designated power range only, please use the included power cord with the instrument. For UK, US and Australian power cords, contact Avantes Technical Support. The 2 Fuses are 1A slow blowing Fuses.
Disconnect power before opening housing or replace Fuse.
The installation category for this equipment is Class 2.
ID:
020624
Revision: 10-01 27
© Avantes BV www.avantes.com [email protected]
3.3.5 Dual Channel AvaSpec-USB2
Specifications of connections and LEDs see section: 3.3.8 AvaSpec LED indicators and I/O connectors. Power connector (only needed if not USB-powered) The power connector is a Low power DC connector with GND on outer contact and +12VDC typical on inner contact. The outside diameter is 5.5mm, the inside diameter is 2.1mm. The electrical circuit accepts voltages between 5 and 15V. Note: Please use Avantes PS-12VDC/2.08A power supply only. Serious damage to the electronics
may occur, when other power supplies with different polarity and/or Voltage ratings are used.
SMA entrance
External IO 26 pole
Scan LED Yellow
Power LED Green
USB2 connectors
Synchronization connector to be connected together
Power connectors
ID:
020624
Revision: 10-01 28
© Avantes BV www.avantes.com [email protected]
3.3.6 Multichannel connections USB2 platform
All spectrometer channels in the Multichannel instrument are internally synchronized. The spectrometer on the far left, as seen from the front, is the master spectrometer, which provides the synchronization signal. This master spectrometer is connected to the HD-26 connector on the backside of the spectrometer.
ID:
020624
Revision: 10-01 29
© Avantes BV www.avantes.com [email protected]
Specifications of connections and LEDs see section: 3.3.8 AvaSpec LED indicators and I/O connectors. Power connector with double Fuse and switch The power connector for 100-240 VAC is located on the rear of the AvaSpec. Be careful to use it with a designated power range only, please use the included power cord with the instrument. For UK, US and Australian power cords, contact Avantes Technical Support. The 2 Fuses are 1A slow blowing Fuses.
Disconnect power before opening housing or replace Fuse.
The installation category for this equipment is Class 2.
ID:
020624
Revision: 10-01 30
© Avantes BV www.avantes.com [email protected]
3.3.7 AvaSpec-UV/VIS/NIR
Specifications of connections and LEDs see section: 3.3.8 AvaSpec LED indicators and I/O connectors. Power connector (only needed if not USB-powered) The power connector is a Low power DC connector with GND on outer contact and +12VDC typical on inner contact. The outside diameter is 5.5mm, the inside diameter is 2.1mm. The electrical circuit accepts voltages between 5 and 15V. Note: Please use Avantes PS-12VDC/2.08A power supply only. Serious damage to the electronics
may occur, when other power supplies with different polarity and/or Voltage ratings are used.
Scan LED Yellow
Power LED Green
USB2 connectors
Synchronization connector to be connected together
SMA entrance External IO 26 pole
Power connector
ID:
020624
Revision: 10-01 31
© Avantes BV www.avantes.com [email protected]
3.3.8 AvaSpec LED indicators and I/O connectors
Power LED green and scan LED yellow The green and yellow LEDs act as status LEDs for the spectrometer with following meaning:
Connection USB
Green LED = off No power
Green LED = on Power is on, spectrometer ready
Green LED = blinking Error detected by spectrometer
Yellow LED = on scanning in progress
External IO 26 pole The external I/O connector is a female high density 26 poles Sub-D connector.
Pin Name Connect to Comment
1 GND GND (DB15-p10 or DB9-p1)
2 DO2 Disable (DB15-p11) general purpose TTL output, max 25 mA*, or used to disable the AvaLight-HAL-(S)-Mini
3 DO5 BSC-DA (Binder768-p1) general purpose TTL output, PWM, max 25 mA*, or used to control the BSC-DA
4 DO8 FOS (DB15-p15)
BSC-DA (Binder768-p3)
general purpose TTL output, max 25 mA*, or used to control the FOS or BSC-DA
5 STROBE AVALIGHT-XE (DB15-p1) Output, one or more TTL pulses per scan, max 50 mA*
6 Trig In External trigger TTL Input, external hardware trigger
7 DI2 TTL input, AvaSoft-Save spectrum
8 GND GND
9 AI1 Analog input, 0-5VDC
10 RX RS-232-TX (DB9-p3) Connect RX to TX of computer
11 DO1 AvaLight-LED (DB15-p2) general purpose TTL output, PWM, AvaSoft-PWM, max 25 mA*
12 DO4 Shutter(DB15-p13) general purpose TTL output , max 25 mA*, or used to close shutter for AvaLight-HAL-S-Mini, AvaLight-DHc and AvaLight-DHS
13 DO7 general purpose TTL output, PWM, max 25 mA*
14 GND GND
15 5VDC DB15-p3 5VDC output, max 25 mA*
16 DI3 TTL input, AvaSoft-Save reference
17 AO1 Analog output, 0-5VDC
18 AI2 Analog input, 0-5VDC
19 TX RS-232-RX (DB9-p2) Connect TX to RX of computer
20 DO3 general purpose TTL output, PWM, max 25 mA*
21 DO6 Long life general purpose TTL output , max 25 mA*, or used for long life mode of the AvaLight-HAL-(S)-Mini
22 DO9 High power general purpose TTL output , max 25 mA*, or used for high power mode of the AvaLight-HAL-(S)-Mini
23 LASER OUT
LASER TTL for LIBS TTL output, AvaSoft programmable delay and duration, max 50 mA*
24 DI1 TTL input, AvaSoft-Save dark
25 DO10 general purpose TTL output, max 25 mA*
26 AO2 Analog output, 0-5VDC
* All DO’s combined cannot supply more than 150 mA
ID:
020624
Revision: 10-01 32
© Avantes BV www.avantes.com [email protected]
USB connector The USB interface has the following physical characteristics:
• USB version 2.0 • high speed, 480 Mbit/s • endpoint node, no HUB function
Synchronization connector SMB miniature 50R coax synchronization connector to synchronize to other AvaSpec-USB2 (or EVO) spectrometers only, order code for SMA cables is IC-COAX-SMB-0,25 for 250mm coax cable. Power switch (-SPU2 version only) Manual switch for power selection for the AvaSpec-SPU2 Left : external power 12VDC, connect external power supply PS-12V/1.0A or 12 VDC Battery pack Middle : OFF Right : USB powered, no additional power supply required Ordering Information Interface cables IC-DB26-2 Interface cable AvaSpec for all Avantes light sources with a DB15
connector IC-DB26/DB9-2 Interface cable AvaSpec to RS232 DB9 cable IC-DB26/DB9/DB15-2 Interface Y cable AvaSpec to RS-232 (DB9) and all Avantes light sources
with a DB15 connector IC-DB26-FOS2-2 Interface Y-cable AvaSpec to FOS-2 and all Avantes light sources with a
DB15 connector IC-USB2-2 Interface cable AvaSpec to USB port on PC, 2m IC-Extrig-USB2 Interface cable AvaSpec to External trigger pushbutton, 2m IC-DB26-Extrig-USB2 Interface Y-cable AvaSpec to External trigger pushbutton and all Avantes
light sources with a DB15 connector IC-DB26-EXTRIG-BNC-2 Interface cable AvaSpec to BNC plug External trigger, 2 m IC-COAX-SMB-0.25 Synchronization coax cable with 2 SMB connectors 0.25m for AvaSpec IC-DB26-BEAM-2 Interface cable AvaSpec to BSC-DA, 2m
ID:
020624
Revision: 10-01 33
© Avantes BV www.avantes.com [email protected]
4 AvaSoft manual
The AvaSoft-Basic software is available for every Avantes spectrometer. The AvaSoft-Full version software contains many additional features and applications. Please see the software section in the Avantes Catalogue for an overview of the extra functionality in AvaSoft-Full. A detailed description about all features in the full version can be found in the help menu. AvaSoft-Basic features are user friendly; it works through mouse oriented pull down menus. The mouse controls movements of a data cursor for instantaneous readout of wavelength, pixel and y-axis magnitude. Mouse dragging is a fast and elegant way to zoom in both x and y direction at the same time. Buttons in the main window are available for on-line/off-line spectral analyses (start/stop), for easy saving of reference, dark and experiment spectra, printing, changing the view to absorbance, transmittance, irradiance or raw scope data, rescaling the y-axis and set scale for x- and y-axis. A spectrum that was saved before can be displayed graphically and compared to other saved spectra, or to the online measured spectra. The user can set the data collection parameters, such as CCD detector integration time, auto-dark correction, signal averaging and spectral smoothing in common dialog boxes. For your AvaSoft manual please refer to:
• Avantes website at the download section www.avantes.com/gettingstarted
• Or the help menu in AvaSoft