VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 1
VMP Pump Modules
TSi-Vc
Zaxis, Inc.
2442 S. 2570 W.
Salt Lake City, Utah 84119
Phone: (801) 264-1000, Fax: (801) 265-8413
Email: [email protected]
Web address: www.zaxisinc.com
VMP-OEM, VMP Micro, VMP500-2
Touch Screen Interface, Teach Pendant.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 2
Table of Contents:
Item Description Page
1. Introduction and Overview ..................................................................................................................................................................... 3
1.1. Safety Instructions ...................................................................................................................................................................... 4
1.2. Theory of Operation………………………………………………………….………………………………………...………….5
1.3. Metering Head Features………………………………………………………………………………………………………… 5
2. System Components ............................................................................................................................................................................... 6
2.1. TSi Controller with 8 Pin Cable (RS485 1/2 Duplex) ................................................................................................................. 6
2.2. “Q” Style Metering Head with Couplers ..................................................................................................................................... 7
2.3. Split Body Style Metering Head (SBSMH) ................................................................................................................................ 8
3. Getting Started ........................................................................................................................................................................................ 9
3.1. General Set-up ............................................................................................................................................................................ 9
3.2. Cables and Connectors…………………………………………………………………………….………………………………10
3.3. TSi Teach Pendant Navigation ................................................................................................................................................... 11
3.4. Mounting the Pump………………………………………………………………………………………….…………………….12
3.5. Start from PLC…………………………………………………………………………………………………………………….13
3.6. Start without PLC…………………………………………………………………………………………………………………14
4. Touch Screen Navigation ....................................................................................................................................................................... 15
4.1. HOME ........................................................................................................................................................................................ 16
4.2. TOOLS…………………………………………………………………………………………………….………………………20
4.3. CLIPBOARD…………………………………………………………………………………………….………………………..21
4.4. Set Pump Number…………………………………………………………………………………………………………………24
4.5. Set Pump PIN (Lock TSi)………………………………………..………………………………………………………………..25
5. Outline Specifications (Electrical and Physical) ..................................................................................................................................... 27
5.1 TSi-Vc……………………………………………………………………….………………………..…………………..…………27
5.2 VMP-OEM “Q Heads”……………………………………………………………………………….……………………………28
5.3 VMP-OEM……………………………………………………………………………...………....………………………………..30
5.4 VMP-Micro………………………………………………………………………………………………………………………….31
5.5 VMP500-2………………………………………………………………………………………………………...…………………33
6. Dispense Volumes .................................................................................................................................................................................. 36
7. Warranty and Spare Parts ....................................................................................................................................................................... 37
8. RS485 and Ethernet Commands……………………………………………………………………………………………………………38
9. Technical Support…………………………………………………………………………………………………………………………..40
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 3
1. Introduction
The Patented VMP system is a precision metering and fluid dispenser combined with a Touch Screen Interface (TSi) for simple
programming and immediate teach and control. This pump technology combines precision ceramic pump components and an
electronically controlled linear stepper actuator to make ultra-fine adjustments to pump angle position, thereby changing the volume
of metered liquid. This allows the VMP system to provide dynamic fluid displacement to overcome variations in viscosity and
surface tension. One of the many attributes of this pump is that it has no valves and has only one moving part, the ceramic piston.
This will provide millions of maintenance free cycles (approximately 84,000,000).
The pump head used in the VMP system is a rotating and reciprocating ceramic piston design. The ceramic piston and the liner
are precision matched sets and the assembly is manufactured to extremely tight tolerances, ensuring the best accuracy and
repeatability. This pump design eliminates the need for external supply and discharge valves. The intake port of the pump is never
connected to the discharge port. The VMP is the latest in fluid metering and dispense technology
Overview
The V-Series:
VMP: A smart Zaxis system with an embedded micro-controller. This unit will communicate directly to a host device
(Computer or PLC) via a serial port, or Ethernet connection. No other controls are needed. The host can be disconnected
and the pump and it will continue its current program.
VMP + TSi Interface will setup up to 32 pumps. All parameters, Volume, speed, number cycles, are all programmed
from the TSi. This system needs an external 24 VDC, 2 amp power source which is available with all VMP Pump
Modules.
System Attributes.
Ceramic and Teflon fluid path available
No valves
0.01 uL resolution
Programmable Stroke adjustment
Embedded micro-controller
100 stored programs
Computer interface, RS485, PLC and Ethernet
Color Touch-Screen Interface
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 4
1.1. Safety Instructions (please read before operating pump and controller)
SAFETY INSTRUCTIONS
Caution: Before using any equipment read the following safety instructions as well as specific
product specifications and operating instructions.
Warning! Fire, Electrical shock or explosion may occur if used near combustibles, explosive
atmosphere, corrosive air, wet environment or submerged in fluid.
Turn off electrical power before checking pump for any problems. Caution! Fire, electrical shock, injury and damage may occur if not
used in accordance with VmP specifications and operation instructions.
Do not operate drive assemblies that require a hard mount (to be bolted
down) unless they are mounted per VmP specifications; if not, injury may occur and/or damage to unit.
Connect motor, controller or any other electrical devices based on VmP
specifications. Any unauthorized work performed on the product by the purchaser or by third parties can impair product functionality and thereby
relieves VmP of all warranty claims or liability for any misuse that will cause
damage to product and/or injury to the individual.
Power cables and leads should not be bent, pulled or inserted by excessive
force. Otherwise there is a threat of electrical shock of fire.
Do not touch any rotating pump or motor components, injury may occur.
Replace any inline fuses only with fuse rating as specified by Zaxis for the VmP
When pump/drive is under operation, never point discharge tubing into face
or touch any rotating components of pump. In a power down thermal
overload cut-in condition, unplug or turn off power to pump. Always allow a cool down period before restarting: otherwise, injury or damage may occur.
Do not run pump dry, unless designed for that service. Running dry is harmful to the pump, and will cause excessive heating due to internal
friction.
Fittings screwed too tightly into stainless steel pump heads will contact port
seals and may cause piston/cylinder damage. Use extra layers of Teflon tape
on threads when necessary to avoid such excessive fitting penetration.
For 30 seconds after power is removed from pump/drive: do not touch any output terminals. Electrical shock may occur because of residual voltage.
Check pump rotation and inlet/outlet pump port orientation before connecting power to pump. If not, injury may occur.
Do not operate with wet hands.
When pulling cords from outlets do not pull cord, grasp plug to prevent plug
damage or electrical shock.
VmP drive motors become HOT and can cause a burn.
DO NOT TOUCH!
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 5
The piston rotates and reciprocates. As the piston is pulled back and the piston flat opens to the inlet port, suction is created and fluid fills the pump chamber. As the piston reaches the highest point in the reciprocation cycle, the pump chamber is now at its maximum volume capacity. Continuing the rotation, the inlet port is then sealed
and crossover occurs. As the inlet port is sealed and the pump chamber is full, the outlet port opens up. Only one port is open at any time and at no time are both ports interconnected.
Continuing the rotation and reciprocation, the piston is forced down and the piston flat opens to the outlet port. Discharge is created and fluid is pumped out. The piston bottoms for maximum fluid and bubble clearing. Continuing the rotation, the outlet port is then sealed
and crossover occurs. As the outlet port is sealed and the pump chamber is empty, the inlet port opens to start another suction stroke. Only one port is open at any time and at no time are both ports interconnected.
1.2. Theory of Operation
The valveless pumping function is accomplished by the synchronous rotation and reciprocation of the ceramic piston in a
precisely mated ceramic cylinder liner. One complete piston revolution is required for each suction and discharge cycle as shown.
The piston always bottoms for maximum fluid and bubble clearing. Moving the pump head position changes the piston stroke
length, varying dispense volume and flow rate. Flow rate indication through the TSi allows for accurate and simple linear
calibration.
1.3. Metering Head Features and Components
Valveless operation with ceramic Piston and Liner.
One moving part in contact with fluid.
Variable Displacement.
Embedded micro-controller and dual amplifier.
Low dead volume.
Low liquid shear.
Self-priming.
Flow Direction Reverse
Panel mounting provisions.
Self-sealing design.
Durability.
Chemically inert.
Autoclavable.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 6
2. System Components.
2.1. VMP-OEM and VMP Micro (VMP Micro in photo below)
1. 24 vdc, 2 amp power supply kit, Zaxis P/N VMP-PSK
2. Foot Switch (Dry Contact), Zaxis P/N VMP-FS
3. Touch Screen Interface, Zaxis P/N TSi-Vc (complete with 8 Pin RS485 Cable)
4. VMP Micro, Zaxis P/N VMP-MOEM
3
2
1
4
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 7
2.2. “Q” Style Metering Heads with Couplers.
Item No. Component Description:
1 Piston
2 Gland Nut
3 Gland Washer
4 Lip Seal
5 Cylinder Liner
6 Cylinder Head Seal
7 Cylinder Port Seal
8 Cylinder Case
9 Coupling Screw, 8-32 x 3/4" Lg. PPH
10 CKC Coupler
Item No. Component Description:
11 CKC Pump
12 CSC Coupler
13 CSC Pump
14 CSCWT Coupler
15 CSCWT Pump
16 WT Coupling Screw
17 Pump Coupler Anchor Screw
18 Pump Coupler Anchor Screw Flat Washer
19 Coupler Knob
20 Coupling Screw, 8-32 x 3/4" Lg. SHCS
21 Universal Coupler
1
8
7
6
2 3
4 5
CKCST Coupling Kit
( V-BRK-CKC )
9
10
11
CSC Coupling Kit
( V-BRK-CSC )
13
9
12
CSCWT Coupling Kit
( V-BRK-CHC )
16
14
15 18
17
CSC/CKC Universal
Coupling Kit
( V-BRK-CSKC )
13
19
20
11
21
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 8
2.3. Split Body Style Metering Head
Item No. Component Description:
1 Piston
2 Cylinder Plate
3 Gland Washer
4 Lip Seal
5 Cylinder Liner
6 Cylinder Head Seal
7 Fitting
8 Cylinder Case
9 Cylinder Port Seal
10 Cylinder Head Seal Comp. Nut
11 Cylinder Head Bolts
12 Cylinder Case Bolts
13 Chromatography Fitting
14
1
2
3
4
5
6
7
9 8
10
11
12
13
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 9
3. Getting Started
Unpack inspect all the components to make sure they are all present and that no damage has occurred.
3.1. General Set-up
Connect the VMP to an appropriate power source (24 VDC) through the 12 Pin I/O Cable. Connect the 8 Pin
RS485 from the TSi to the RS485 receptacle. For VMP500-2 a separate 110/220VAC will power the unit; see page 10
and 29 for details of PLC connection.
See rear of VMP Modules below:
12 and 8 Pin Cables (straight or 90 degree)
110/220 VAC Power Cord
VMP-OEM and VMP Micro --
VMPXXX-2 ----
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 10
3.2 Cable and Connector Specifications:
AC Power, for VMP500-2
Specification Sheets
Output connector Product Contacts 3+PE, 4 x 1.5 PVC: female cable
connector injection-moulded cable
Pole 3+PE
Area RD24 Power Series 692/693
Article number 79 0232 20 04
Common values Connector Design Female cable connector
Connector locking system screw
Termination crimp, injection-moulded cable
Wire gauge (mm) 1.50 mm²
Wire gauge (AWG) 16
Cable outlet -
Upper temperature 80 °C
Lower temperature -25 °C
Cable data material housing PVC black
Insulation single lead PVC sw 1, sw 2, sw 3,
green/yellow
Single lead structure 28x0.25 mm
Cable sheath Ø 8.6
Conductor resistance –
Bending radius cable fixed 120 mm
Bending radius cable movable 60 mm
Approval UL, CSA
Electrical values Rated voltage 400 V
Rated impulse voltage 6000 V
Pollution degree 3
Overvoltage category III
Material group III
Rated current (40°C) 16 A
Volume resistivity ≤ 5 mΩ
EMV compliance not shielded
Degree of protection IP67
Mechanical operation > 500 mating cycles
Material Material of contact CuZn (Brass)
Contact plating Ag (Silver)
Material of contact body PA 12
Material of housing PUR
Contacts 3+PE, 4x1.5 PVC: female cable connector injection-moulded cable, cable length 2 m
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 11
3.3 Cables and Connectors
8 Pin and 12 Pin I/O and RS485 Cables, available with straight and right angle connectors, and wire only leads.
Specifications
Locking System: M12 A-Coding
Number of Contacts: 12
Gender: Male
Shell Material: Plastic
Maximum Diameter (mm): 14.5
Mounting Style: Cable-mounted
Termination: Overmolded
Protection: IP 68
Shielding: non-shielded
Contact Plating: Gold
Rated Voltage (V): 30
Rated Current (A): 1
Cable Length (M): 2
Form: Straight
Series 763: Single-ended cordset, male plug, 2m PUR cable
Part # 79 3495 32 12
Overmolded
non-shielded
Contacts: 12
Contact Plating: Gold
IP 68
M12 A-Coding
Specifications
Locking System: M12 A-Coding
Number of Contacts: 8
Gender: Male
Shell Material: Plastic
Maximum Diameter (mm): 14.5
Mounting Style: Cable-mounted
Termination: Overmolded
Protection: IP 68
Shielding: non-shielded
Contact Plating: Gold
Rated Voltage (V): 60
Rated Current (A): 2
Cable Length (M): 2
Wire Gauge (max AWG): 24
Form: Right-angle
Series 763: Single-ended cordset, 90° male plug, 2m PUR cable
Part # 79 3477 32 08
Overmolded
non-shielded
Contacts: 8
Contact Plating: Gold
IP 68
M12 A-Coding
This is for the VMP-
OEM only. For VMP
Dual or VMP500-2 12
Pin Cable please see
page 35
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 12
3.4 Mounting the Pump
When mounting the pump to the drive, the pump must be oriented as shown in the illustration below. Note: Pump damage will
occur if the pump is mounted incorrectly. Once the pump is mounted, the tubing can be connected. For the Inlet (Suction) side of
the pump (preferably the lower side), use tubing with the largest inside diameter that your application will allow. This will
minimize the chance for cavitation. For the Outlet (Discharge) side of the pump, use tubing with an inside diameter equal to or
smaller than the inlet tubing. This will result in best metering performance and minimize fluid variation from the dispensing tip.
Revs Per Minute (RPM) recommendations: For fluids of 500cps viscosity or less a stroke rate of 120-350 RPM
maximum is ideal. For fluids with greater than 500cps a slower rate is recommended.
Correct Mounting Orientation Incorrect Mounting Orientation
X
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 13
3.5 Start the Pump from PLC
Start the VMP-OEM from PLC:
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 14
3.6 Start the Pump
Start the VMP-OEM from power supply kit- (3 Pump version below as reference)
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 15
4.0 Touch Screen Navigation
TSi-Vc Teach-Pendant Navigation - Navigating around the TSi Touch-Screen is quite simple.
The TSi-Vc information screen provides
the TSi’s and VMP’s firmware revisions
as well as the serial number. You can
always contact Zaxis direct for technical
support.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 16
4.1 Home Screen
[ Home 1 ] Screen Tab: These are the control buttons of the VMP pump
[ = ]: Stroke Adjustment will move to ZERO then to program setting.
[ Pump# ] Program number of the pump. The Display will communicate to 32 pumps
concurrently. A host CPU will communicate with many more
[ Program Name ] You can name a program by selecting this field.
Run =The current program will run at the current settings.
Direction of pumping. Piston flat is towards inlet and arrow indicates flow direction
[ MAX ] This function is to automatically adjust to full stroke, (purge). By pushing the equals (=) button, the pump
will return to program volume.
This allows the pump to pump continuous.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 17
[ Home 1 ] Screen Tab Continued-
This allows the pump to perform a dispense. Dispense can be multiple revolutions.
[ Prog ] This allows the user to being up a keypad to select a stored program.
[ Volume ] This allows the user to being up a keypad to select Volume in milliliters. The pump is repeatable to .2
microliter.
[ Current Volume ] This is the actual volume of the pump. Only after the run button is selected
[ RPM ] Speed can be controlled from 60 to 1000 RPM, and while in continuos mode, you can adjust speed up or
down without stopping the pump. There are limitations to speed and pressure, based on the fluidic system.
[ Revolutions ] This allows the user to being up a keypad to select the number of Cycles. The pump rotates 360
Degrees per cycle. If pullback is used, then the pump makes up the pullback, then rotates 360 degrees.
[Total] number is the product of the Volume and the Revs.
This allows the user to stop the dispensing. Used when large volume is being dispensed.
Program Linking is factory set to OFF. See Home Screen 2 for details
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 18
[ Home 2 ]Link Screen Tab
These buttons are extended functions.
[ Pullback ] This allows the user to reverse the pump direction for suck-back. It is in percentage of rotation, for
example 100 would be one rotation. Then the pump makes up the suck back and dispenses the next shot.
[ Linked Prog# ] This allows the user to link to another program.
[ Delay ] This allows the user to select the delay time in seconds before the next linked program runs.
[ Cycles ] LOOP CYCLES This allows the user to enter the number of loops to the next program. This is not the
same as REVS. The pump will perform the REVS, in a saved program, then the link occur and repeat as programmed
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 19
[ Home 2 ] Advanced Motor Controls –
[ Acceleration ] This allows the user to modify the VMP acceleration
[ Deceleration ] This allows the user to modify the VMP deceleration
[ Approx. Time ] This field displays the time for a full revolution
[ Motor Current ] This allows for the user to adjust motor current, saving power, or to reduce heat
[ RPM ] This allows for change to RPM, same as Home screen page 1
[ Initial RPM ] This allows the user to adjust the initial RPM
[ Final RPM ] This allows the user to adjust the final RPM
Please consult the factory before changing any default settings. Advanced
controls are useful for special applications that need to optimize pumping
performance. For example, high and low viscosity fluid.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 20
4.2 Tools
[ Tools ] Screen Tab
[ Bore ] This is the bore size of the piston in inches. VMP pump heads are interchangeable and the new bore size can
be entered if a different pump piston size is used.
[ Cal Factor ] This is determined by the factory for each model of VMP pump
The radial buttons are used to select pump model and type, including the the pitch
screw of the stroke volume adjustment motor. These are factory settings and you
should consult the factory before changing anything. On pages 25 and 26 there is a
procedure for locking this part of the controller.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 21
4.3 Clipboard
[Clipboard] Ethernet Settings
Select the Ethernet Settings button and you will see the below screen with factory defaults for TCP/IP
Settings. The VMP pump can be controlled by Ethernet commands on pages 39 and 40. The most basic
way to use Ethernet is through a terminal emulation program like HyperTerminal, and a crossover
Ethernet cable.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 22
[Clipboard Continued] Set Pump Number
To change a pump number, select the radial button for the number of the pump you want it to be. Now
select the “Send Change Command top Pumps” . You now have 10 seconds to push the pump set button
on the VMP drive. See photo below. You will know the selection is complete after the serial number of the
pump is now located at the radial button and pump number you have selected.
Pump Set button
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 23
[Clipboard Continued] Ready Input and Touchscreen Calibration
The ready is factory closed (OFF). Ready can be used a safety interlock before a pump start signal
can be allowed. Please see the start diagram below for reference and page 13 for PLC control.
Use this button to calibrate the TSi-Vc
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 24
4.4 [ Pump# ] Set Pump Number Screen Tab
The radial buttons for pump# allows you to view and select which pump you want to
program. The pump’s serial number will appear if it is in serial connection (RS485) to
the TSi. Up to 32 VMP pumps can be connected to one TSi. If you select ALL, the TSi
will communicate and run every pump on the RS485 connection. Select the Pump#
button to return to the HOME screen to run selected pump(s)
[ Lock TSi ] Screen Tab 1
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 25
4.5 [ PIN] Set and Enter PIN
Press the LOCK button to assign a PIN to the TSi
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 26
[ Lock TSi ] Screen Tab 2
If you entered a PIN, the lower right hand corner will change to lock position and color blue.
To unlock, press the blue button (in locked positon) and enter your PIN. The factory default
is NO pin, just select ENTER . PIN must be four numbers.
To change PIN, go to CLIPBOARD and select Change Pin. You will need to enter your old PIN
then assign a new PIN, re-enter, then proceed.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 27
5.1 Outline Specifications
Touch Screen Interface, TSi-Vc Electronic Controller
Material of Construction: Painted Polyvinyl Chloride (PVC).
Physical Specifications: Dimensions: 7.5” x 5” x 1” Weight: 12 oz.
Electrical Specifications: Power: 5 VDC, 1/2 Duplex RS485 (Typical power received from VMP module)
.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 28
Panel Cut-out Dimensions
5.2 VMP OEM (Q Pump) Motor Module
Mounting: The motor module can be bulkhead or panel mounted. It also has an optional stand that allows it to set on a bench or
tabletop.
Materials of Construction: Piston and cylinder lining are sapphire hard (fused crystalline alumina, 99% Aluminum Oxide).
The motor module body is constructed from 6061 aluminum with surface black anodizing.
Physical Specifications:
Dimensions: 9 ” x 4.44” x 3.0” Weight: 4 lbs.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 29
17
5.3 VMP OEM Motor Module
Mounting: The motor module can be bulkhead or panel mounted. It also has an optional stand that allows it to set on a bench or
tabletop.
Materials of Construction: Piston and cylinder lining are sapphire hard (fused crystalline alumina, 99% Aluminum Oxide).
The motor module body is constructed from 6061 aluminum with surface black anodizing.
Physical Specifications:
Dimensions: 9 ” x 4.44” x 3.0” Weight: 4 lbs.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 30
5.4 VMP Micro
Mounting: The motor module can be bulkhead or panel mounted. It also has an optional stand (shown with stand below) that
allows it to set on a bench or tabletop.
Materials of Construction: Piston and cylinder lining are sapphire hard (fused crystalline alumina, 99% Aluminum Oxide).
The motor module body is constructed from 6061 aluminum with surface black anodizing.
Physical Specifications: Dimensions: 208 x 75 x 101 (mm) Weight: 7 lbs.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 31
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 32
5.5 VMP500-2
Mounting: The VMP500-2 is a dual channel filling and metering system. It is typically mounted on a shelf, rack, or cart system,
It comes complete with mounting provision front and back, as well as rubber feet.
Materials of Construction: Piston and cylinder lining are sapphire hard (fused crystalline alumina, 99% Aluminum Oxide).
The Pump wetted path is Ceramic, Teflon, and 316LSS, including a IP45 SS Enclosure intended for Food and Pharma
GMP applications. Product shown with V3SAN pump head module
Physical Specifications: Dimensions: 400 x 191 x 186 (mm) Weight: 23 lbs.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 33
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 34
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 35
VMP500 External Wiring, PLC and DC Power
Start In
Ready In
Busy Out
Count Out
1. I/O + Brown
2. I/O - Blue
3. Busy A (out) White
4. Count A (out) Green
5. Start A (In) Pink
6. Ready A (In) Yellow
7. Busy B (out) Black
8. Count B (out) Grey
9. Start B (in) Red
10. Ready B (in) Purple
11. Not used Grey /Pink
12. Not Used Red/blue
Pin No. Label Pump Receptacle P/N
Mating Cable: Right angle flying leads:
77-3427-3427-50712-0022
Straight cable: 79 3495 32 12
VMP-500, Dual VMP rear 12 pin
Connector
24 VDC & Input/Ouput
Series 763: Female receptacle,
rear-mounted, PCB solder,
6mm contact length
Part # 09-3492- 500-12
PCB solder
non-shielded
Contacts: 8
Contact Plating: Gold
IP 68
M12 A-Coding
Warning!
Special
connections
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 36
6.0 Dispense and Metering Volumes
Below are the maximum dispensing volumes for each VMP pump head. It is recommended
to use the pump head max and size that is nearest your dispense volume. If you are
planning to make frequent volume changes and or continuously meter with the VMP pump,
please contact the factory for a suggested pump head size to meet your specific needs.
Each VMP pump is factory inspected and verified at 100%, 50% and 10% of max volume. If
you require specific calibration process, please contact Zaxis factory.
Metering Volumes
The VMP drive is capable of 1000 RPM in some applications. For continuous metering volumes
please see the chart above. For applications of 500mL or higher you will require a minimum of 1/2” ID
tubing. Low flow applications that require a flow rate of less than 50 mL/min should consider low flow
options from Zaxis. Please contact Zaxis factory for any questions.
VMP Pump Heads
Pump Bore Volume (mL) mL/min
1/4" 0.320 320
3/8" 0.720 720
1/2" 1.280 1280
VMP Micro Pump Heads
1/4" 0.100 100
3/16" 0.050 50
1/8" 0.025 25
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 37
ONE YEAR LIMITED WARRANTY
Zaxis, Inc. Limited Warranty ZAXIS INC. products are manufactured to a high level of mechanical precision from materials that are resistant to attack by
many corrosive chemicals. These products, however, may be self-destructive when used with non-compatible fluids or when
located in physically hostile environments or when operated under non-specification voltage or pressure conditions.
ZAXIS INC., therefore, warrants only as follows:
Each metering head has been test operated with water to rated pressure prior to shipment from the factory. The qualifying
performance of each metering head is recorded by serial number in a permanent record of the company. If at any time with-in
the first year after any ZAXIS INC. product has been shipped to a customer (user), it fails to perform according to ZAXIS
INC. literature, the product, with written explanation of the problem, may be returned, freight prepaid, to ZAXIS INC. for
examination, repair or replacement at ZAXIS INC. expense (labor and material). All such returns must have prior ZAXIS
INC. customer service authorization before returning. If, upon examination, ZAXIS INC. determines that abusive practices,
non-compatible fluids or destructive environment of operation or a combination of these factors is responsible for improper
performance of the product, all labor and materials costs involved shall be at the expense of the customer.
ZAXIS INC. is not liable for special, indirect or consequential damages that may result from use, failure or malfunction of the
product, and any recovery against ZAXIS INC. may not be greater than the purchase price paid for the product.
No person is authorized to change the terms of this warranty.
6. Warranty
7.1 Recommended Spare Parts List
Please contact the factory for recommended spares to your VMP pump model. The VMP pump is designed for millions of
maintenance free cycles. Each application will vary in the basic need for preventive maintenance (PM) . It is common to have a
spare pump head in most applications. Please contact the factory for return authorization if you would like to return a VMP Pump.
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 38
VMP Commands, RS485 (For Ethernet-do not use a preceding number for pump ID
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 39
VMP Commands Continued
VMP Query Commands
VMP Users Manual 2015B
VMP Variable Metering Pump User Manual
US Patent # 7,708,535 40
7. Technical Application Support:
Please call Zaxis and let us know about your application. Zaxis metering and dispense pumps
are the latest in positive displacement technology.
Zaxis, Inc.
2442 S. 2571 S.
Salt Lake City, Utah 84119
Phone: (801) 264-1000, Fax: (801) 265-8413
Email: [email protected]
Web address: www.zaxisinc.com