vlt microseries - tecdriver.com.br micro catalog.pdf · ® microseries drives solutions. tel....

16
VLT ® 2800 Series: VLT ® MICRO Series Drives Solutions

Upload: others

Post on 24-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

VLT® 2800 Series:

VLT®

MICRO S e r i e s

Drives Solutions

Page 2: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

tel. 800.432.6367

ContentsA 2 Overview and Features

A 6 Performance Data

A 8 General Technical Data

A 10 Dimensions and Mounting

A 12 Options

A 16 Ordering Information

The Ideal Drive for Limited Space

The VLT® MICRO is the perfect drive for OEMs andpanel builders needing a small AC motor control in the1/2 to 2 HP, 230 VAC and 1 to 3 HP, 460 VAC range. Itoffers a small footprint, sophisticated control and a userfriendly keypad. To top it off, it has excellent reliabilityand simple functionality ... all at a low price!

VLT MICRO (230 VAC 3Ø) shown actual size

VLT® MICRO Series Overview

Page 3: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

Drives Solutionstel. 800.432.6367

VLT

® MIC

RO

A

VLT MICRO Features and Benefits• Simple installation

• Panel or optional DIN rail mount

• Optional remote keypad mounting kit

• Compact overall size saves space and installation cost

• Designed for: 1/2 to 2 HP, 230 VAC constant torque applications

and 1 to 3 HP, 460 VAC constant torque applications

• Programmable DC braking makes it easier to adapt the unit to

various applications

• All models are enclosed in a protected chassis (IP 20) and are UL

and cUL listed

• Easy access to all terminal connections

• Programmable digital inputs and outputs

• Forced air-cooled

• Low noise operation

• Provides DC performance from a low cost and low maintenance AC

motor

• Overload current — 150% of rated current for 1 minute

• Automatic voltage regulation

• S-curve or linear ramp profiles

• Momentary power failure restart

• Parameter lock/reset

Protection Features• Self-testing

• Over-voltage

• Over-current

• Under-voltage

• Overload

• Over-heating

• External fault

• Electronic thermal

• Ground fault

Applications• Conveyors

• Pumps

• Fans

Application photo

Application photo

Application photo

Options• Remote keypad kit

• Din rail adaptor kit

• Brake resistors

• EMC filters

Page 4: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

tel. 800.432.6367

Features – Keypad and Display Functions

Built-in software eliminates the needfor additional hardware — savingspace, time and money

ENTER

MODE

RUN

STOPRESET

RUN STOP

FWD REV

DIGITAL KEYPAD

VLT® MICRO

FREQ. SET0 100

50

RUN

STOPRESET

RUN FWD REVSTOP

ENTER

MODE

Digital Controls Make Operating a Breeze

The digital keypad/display module comes mounted on the front panel

of the VLT MICRO. This module has two functions: display and control.

Display shows the current status of the drive. Control provides the

programming interface. As you'll see, running the VLT MICRO couldn't

be easier!

Function/Program Mode

Pressing the “MODE” key repetitively displays the status,

such as the reference frequency, output frequency, or

output current.

Enter

Pressing the “ENTER” key stores the parameters in

memory.

Run

This key is used to start operation. It has no effect when

the drive is controlled by the external control terminals.

Stop/Reset

This stops and resets the parameter after faults occur

with the drive.

Up/Down

Press the “Up” or “Down” keys momentarily to change

parameter settings. These keys may also be used to scroll

through different operating values or parameters.

LED Indicators

These indicators light up during RUN, STOP,

FWD and REV operations.

Page 5: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

Drives Solutionstel. 800.432.6367

VLT

® MIC

RO

A

Features – Installation and Start-up

Parameter SettingsSet the following parameters according to the motor nameplate:

Maximum motor frequency ................................................. Parameter 04

Maximum motor voltage ..................................................... Parameter 05

Motor rated current .............................................................. Parameter 52

Set the ramp times:

Accel time ....................................................................... Parameter 10

Decel time ...................................................................... Parameter 11

Set ramp selection:

d00 linear accel/decel .................................................. Parameter 101

Motor StartPress the Run key to start the motor. Adjust desired speed using the Up

and Down arrow keys.

ProgrammingThe VLT MICRO is programmed by means of the digital keypad. In

order to operate in the Quick Set-Up Mode the Pin Header/Jumpers

(located next to the input terminals) should all be set in the up

position.

Note: Speed reference is controlled by the Up and Down arrow keys. If a

potentiometer is to be used as the speed reference parameter, Parameter

00 will need to be programmed to d01.

Parameter 52 = x 100Motor Full Load Amps

Drive Max Cont. Amps

J5J6J7

WiringThere are two wiring systems in

an AC motor drive: the power

wiring and the control circuit.

The power wiring terminals are

located at the top of the drive.

Control Circuit terminals are

located at the bottom of drive.

All terminals blocks are covered

by a plastic housing, which can

be lifted to gain access to the

terminals. When no connections

are made to the control

terminals, the drive can be

operated by the digital keypad/

display.

R

S

T

GND

MO

M1

M2

M3

M4

M5

U

V

W

B1 B2

AFM

RB

RA

RC

MO

MCM

GND

3

2

1GND

+

-

Forward/Stop

Reverse/Stop

Reset

Multi-Step 1

Multi-Step 2

Multi-Step 3

Signal Common

200-240 VAC 50/60 Hz(Select each two terminals asinput for single or three phase power input models)

380-480 VAC 50/60 Hz

Braking Resistor (Option)

ACMotor

AnalogFrequency/CurrentMeter

Alarm Output Contacts30 VDC 2A Max250 VAC 2A Max

Multi-function PHC output48 V/250mA Max

Digital Signal Input Terminals

Frequency Setting0~10 VDC 1k - 5k Current Input 4-20 mA

Analog/Digital Signal Common

Power forspeed setting

+10 V 10mA(max.)

AVI

RS-485

Page 6: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

tel. 800.432.6367

Performance Data – 1Ø or 3Ø 200-240 VAC

VLT Order Number 1/3Ø UL 176F7300 176F7301 176F7302

1/3Ø UL/CE 176F7306 176F7307 176F7308

Output

Output Current

Continuous (200-240 VAC) [A] 2.5 5.0 7.0

Intermittent (200-240 VAC) [A] 3.7 7.5 10.5

Continuous KVA (200-240 VAC) [KVA] 1.0 1.9 2.7

Typical Shaft Output [HP] 0.5 1.0 2.0

Max. Motor Cable Size [AWG] 14 14 14

[mm2] 2 2 2

Input

Max. Input Current (1Ø, 200-240 VAC) [A] 6.3 11.4 15.7

(3Ø, 200-240 VAC) [A] 2.9 6.3 8.8

Max. Power Cable Size [AWG] 14 14 14

[mm2] 2 2 2

Max. Pre-Fuses1) [A] 10 20 25

Environment

Estimated Power Loss at Rated Max. Load (240 VAC) [W] 34 61 94

Enclosure Protected Chassis (IP 20)

Weight 1Ø [lbs.] 1.75 2.0 2.25

3Ø [lbs.] 1.75 1.75 2.0

1) 200-240 VAC; Bussmann JJN type or exact equivalent

Recommended Bussman

Type JJN or JJS Input Fuses Part Number

0.5 HP 230 VAC 1Ø JJN 10

1 HP 230 VAC 1Ø JJN 20

2 HP 230 VAC 1Ø JJN 25

0.5 HP 230 VAC 3Ø JJN 10

1 HP 230 VAC 3Ø JJN 20

2 HP 230 VAC 3Ø JJN 25

Page 7: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

Drives Solutionstel. 800.432.6367

VLT

® MIC

RO

A

Performance Data – 3Ø 380-480 VAC

VLT Order Number 3Ø UL/CE 176F7312 176F7313 176F7314

Output

Output Current

Continuous (380-480 VAC) [A] 3.0 4.0 5.0

Intermittent (380-480 VAC) [A] 4.8 6.1 8.1

Continuous KVA (380-480 VAC) [KVA] 2.3 3.1 3.8

Typical Shaft Output [HP] 1.0 2.0 3.0

Max. Motor Cable Size [AWG] 14 14 14

[mm2] 2 2 2

Input

Max. Input Current (380-480 VAC) [A] 4.2 5.7 7.0

Max. Power Cable Size [AWG] 14 14 14

[mm2] 2 2 2

Max. Pre-Fuses1) [A] 10 15 20

Environment

Estimated Power Loss at Rated Max. Load (460 VAC) [W] 59 82 113

Enclosure Protected Chassis (IP 20)

Weight [lbs.] 2.25 2.5 2.75

1) 380-480 VAC; Bussmann JJN type or exact equivalent

Recommended Bussman

Type JJN or JJS Input Fuses Part Number

1 HP 460 VAC 3Ø JJS 10

2 HP 460 VAC 3Ø JJS 15

3 HP 460 VAC 3Ø JJS 20

Page 8: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

tel. 800.432.6367

General Technical Data

AC Line Supply (R, S, T):Supply voltage single-phase 200-240 V units ................................................................................................................... 1 x 200/208/220/230/240 V ±10%

Supply voltage three-phase 200-240 V units .................................................................................................................... 3 x 200/208/220/230/240 V ±10%

Supply voltage 380-480 V units .................................................................................................................................. 3 x 380/400/415/440/460/480 V ±10%

Supply frequency ......................................................................................................................................................................................................... 50/60 Hz

Max. imbalance of supply voltage ............................................................................................................................................... ±2% of rated supply voltage

Power factor .............................................................................................................................................................................................0.90/1.0 at rated load

Switching on supply input L1, L2, L3 ........................................................................................................................................................ max. 100 times per

Max short circuit rating .................................................................................................................................................................................................. 5000 A

Efficiency .............................................................................................................................................................................................................................. 0.95

VLT Output Data (U, V, W):Output voltage ................................................................................................................................................................................... 0-100% of supply voltage

Output frequency .................................................................................................................................................................................................... 0.1 - 400 Hz

Rated motor voltage, 200-240 V units ................................................................................................................................................ 200/208/220/230/240 V

Rated motor voltage, 380-480 V units ........................................................................................................................................ 380/400/415/440/460/480 V

Rated motor frequency ................................................................................................................................................................................................ 50/60 Hz

Switching on output .................................................................................................................................................................................................. Unlimited

Ramp times .............................................................................................................................................................................................................. 0.1-600 sec.

Torque Characteristics:.Starting torque ................................................................................................................................................................................................. 150% for 1 min.

Starting torque ....................................................................................................................................................................................................200% for 5 sec.

Acceleration torque ............................................................................................................................................................................................................ 100%

Overload torque ............................................................................................................................................................................................... 150% for 1 min.

Control Card, Digital Inputs:Number of programmable digital inputs ................................................................................................................................................................................ 6

Terminal nos. .................................................................................................................................................................................... M0, M1, M2, M3, M4, M5

Control Card, Analog Inputs:No. of programmable analog inputs (selectable voltage or current) .................................................................................................................................... 1

Terminal number ................................................................................................................................................................................................................ AV 1

Voltage level ............................................................................................................................................................................................................... 0 - 10 VDC

Input resistance, Ri............................................................................................................................................................................................ approx. 47 kΩ

Current range .............................................................................................................................................................................................................. 4 - 20 mA

Input resistance, Ri............................................................................................................................................................................................ approx. 250 Ω

Resolution ..............................................................................................................................................................................................................10 bit + sign

All analog inputs are galvanically isolated from the supply voltage.

Control Card Analog Outputs:Number of programmable analog outputs ............................................................................................................................................................................. 1

Terminal numbers ............................................................................................................................................................................................................... AFM

Voltage range at analog output ................................................................................................................................................................................0 - 10 VDC

All digital and analog outputs are galvanically isolated from the supply voltage.

Page 9: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

Drives Solutionstel. 800.432.6367

VLT

® MIC

RO

A

General Technical Data

Control Card, 10 VDC Supply:Terminal number .............................................................................................................................................................................................................. +10V

Max. load .......................................................................................................................................................................................................................... 10 mA

Digital OutputNumber of programmable optocoupler outputs ..................................................................................................................................................................... 1

Terminal numbers .................................................................................................................................................................................................... MO1-MCM

Max. output ...................................................................................................................................................................................................... ≤48 VDC, 50 mA

Control Card, RS485 Serial Communication:Terminal number ............................................................................................................................................................................................................. RJ -11

Relay Outputs:No. of programmable relay outputs ........................................................................................................................................................................................ 1

Terminal numbers ......................................................................................................................................................... RA-RC (N.O.), RB-RC (N.C.) Form C

Max. terminal load rating ........................................................................................................................................................................ 120 VAC/28 VDC, 5 A

240 VAC, 2.5 A

Brake Resistor Terminals:Terminal numbers ........................................................................................................................................................................................................... B1, B2

Cable Lengths and Cross-Sections:Use 75°C copper wire minimum

Max. motor cable length .....................................................................................................................................................................................165 ft. (50 m)

Max. cable cross-section for line, motor and brake ...................................................................................................................................14 AWG (2.0 mm2)

Max. cross-section for control terminals .................................................................................................................................................... 14 AWG (2.0 mm2)

Control Characteristics:Frequency range ..................................................................................................................................................................................................... 0.1 - 400 Hz

Resolution on output frequency ...................................................................................................................................................................................±0.1 Hz

Speed, control range (open loop) .......................................................................................................................................................... 1:20 of synchro. speed

Speed, accuracy (open loop) ........................................................................................................................................................ < 1800 rpm: max. error 2%

> 1800 rpm: max. error of 0.5% of actual speed

All control characteristics are based on a 4-pole asynchronous motor

Environment:Enclosure ......................................................................................................................................................................................... Protected Chassis (IP 20)

Vibration test ..................................................................................................................................................................... 1 g less than 20 Hz, 0.6 G 20-50 Hz

Max. relative humidity ......................................................................................................................................................... less than 90% (non-condensing)

Ambient temperature ............................................................................................................................................................................................ –10 - +50°C

Temperature during storage/transport ................................................................................................................................................................ –20 - +60°C

Max. altitude above sea level ........................................................................................................................................................................ 3300 ft. (1000 m)

VLT MICRO Series Protection:• Self-testing, over-voltage, over-current, under-voltage, overload, over-heating, external fault, electronic thermal, ground fault

Page 10: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

tel. 800.432.6367

Mechanical Dimensions and Mounting Requirements

VLT MICRO Order Numbers

176F7300, 176F7301, 176F7302 (1/2-2 HP) 200-240 VAC

1/3Ø 200-240 VAC in (mm)

1 HP/ 0.75 KW230V 3PHASE

WARNING:Do not connect AC power tooutput terminals (U,V,W).Do not inspect componentsuntil LEDs are turned offfor at least 1 min.

DIGITAL KEYPAD

VLT® MICRO

FREQ. SET0 100

50

RUN

STOPRESET

RUN FWD REVSTOP

ENTER

MODE

MOTOR

V WU B1 B2

0.47(12)

4.45(113)

4.72(120)

0.47(12)

5.57(141.5)

3.35(85)3.13

(79.5)

Ø0.196(5) 0.216

(5.5)

0.216(5.5)

0.216(5.5)

AIR

1.97(50)

or more

1.97(50)

or more

4.72 (120)or more

4.72 (120)or more

1 HP / 0.75 KW230V 3 PHASE

WARNING:Do not connect AC power tooutput terminals (U,V,W).Do not inspect componentsuntil LEDs are turned offfor at least 1 min.

DIGITAL KEYPAD

VLT-MICRO

FREQ. SET0 100

50

RUN

STOPRESETENTER

MODE

RUN FWD REVSTOP

Mounting RequirementsInstallation of the VLT MICRO is simple! The drive should be installed

vertically to provide proper ventilation with adequate space between the

drive and a wall or other equipment, and should be mounted in an

enclosure appropriate for the application environment.

Page 11: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

Drives Solutionstel. 800.432.6367

VLT

® MIC

RO

A

in (mm)

WARNING:Do not connect AC power tooutput terminals (U,V,W).Do not inspect componentsuntil LEDs are turned offfor at least 1 min.

DIGITAL KEYPAD

VLT® MICRO

FREQ. SET0 100

50

RUN

STOPRESET

RUN FWD REVSTOP

ENTER

MODE

MOTOR

V WU B1 B2

0.39(10)

4.55(115.5)

4.86(123.5)

0.39(10)

5.94(151)

3.94(100)3.72

(94.5)

Ø0.196(5) 0.216

(5.5)

0.216(5.5)

0.216(5.5)

VLT MICRO Order Numbers

176F7306, 176F7307, 176F7308 (1/2-2 HP) 200-240 VAC

176F7312, 176F7313, 176F7314 (1-3 HP) 380-480 VAC

1/3Ø 200-240 VAC CE Models3Ø 380-480 VAC CE Models

AIR

1.97(50)

or more

1.97(50)

or more

5.91 (150)or more

5.91 (150)or more

1 HP / 0.75 KW230V 3 PHASE

WARNING:Do not connect AC power tooutput terminals (U,V,W).Do not inspect componentsuntil LEDs are turned offfor at least 1 min.

DIGITAL KEYPAD

VLT-MICRO

FREQ. SET0 100

50

RUN

STOPRESETENTER

MODE

RUN FWD REVSTOP

Mounting RequirementsInstallation of the VLT MICRO is simple! The drive should be installed

vertically to provide proper ventilation with adequate space between the

drive and a wall or other equipment, and should be mounted in an

enclosure appropriate for the application environment.

Mechanical Dimensions and Mounting Requirements

Page 12: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

tel. 800.432.6367

Options – Brake Resistors

200-240 VAC VLT MICRO Brake Resistors

HP VAC Ohms Pmax (W) Order Number Duty Cycle

0.5 200-240 330 250 (A) 175U1003 30%

0.5 200-240 160 175U0900 40%

0.75 200-240 220 250 (A) 175U1004 20%

0.75 200-240 250 (A) 175U0901 40%

1 200-240 150 250 (A) 175U1005 14%

1 200-240 150 250 (A) 175U0989 30%

1 200-240 320 175U0902 40%

2 200-240 72 500 (B) 175U0992 15%

2 200-240 850 175U0903 40%

380-2480 VAC VLT MICRO Brake Resistors

1 380-460 620 250 (A) 175U1001 10%

1 380-460 620 500 (B) 175U0982 30%

1 380-460 320 175U0910 40%

2 380-460 310 500 (B) 175U0984 15%

2 380-460 850 175U0912 40%

3 380-460 210 500 (B) 175U0987 5%

3 380-460 1000 175U0913 40%

Drawing A: 250 W Resistors Drawing B: 500 W Resistors VLT MICRO Brake Resistor Mounting Brackets

Mounting Bracket Dim A Part Number

For 250 W Resistors 4.34 (110) 175U0011

For 500 W Resistors 8.52 (216) 175U0009

4.33(110)

3.15(80)

0.59(15)

8.50(216)

3.15(80)

0.59(15)

0.2(5)

0.79(20)

A

1.22(31)

0.71(18)

0.79(20)

in (mm)

in (mm)

Page 13: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

Drives Solutionstel. 800.432.6367

VLT

® MIC

RO

A

Options – Remote Keypad Kit

D I G I T A L K E Y P A D

STOPRESETENTER

MODE RUN

FREQ. SET

50

1000

RUN STOP FWD REV

1.44(36.5)0.14

(3.5)

0.12(3.0)

2.76(70.0)

1.30(33.0)

0.12(3.0)

0.53(13.5)

1.50(38.0)

0.63(16.0)

0.77(19.5)

Dimensions for Remote Mounting ofDigital Keypad/Display

0.55(14.0)

1.02

(26.

0)

A1.09

(27.8)1.04

(26.5)1.44

(36.5)

1.43

(36.

4)

0.65(16.4)

Dimension A Value Part Number

6 ft. (2 m) 176F7310

15 ft. (5 m) 176F7325

The VLT MICRO provides a removable Keypad/Display that may be

mounted remotely using one of the optional cables (6 ft. or 15 ft.). This

is particularly helpful in providing access to unit parameters or

monitoring operation when the Keypad/Display is mounted on a

control panel’s cover.

in (mm)

Page 14: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

tel. 800.432.6367

Options – RFI Filter

Part Number

200-240 1Ø 176F7327

200-240 3Ø 176F7328

380-480 3Ø 176F7326

Dimensions for Model 176F7328

The optional RFI Filters provide compliance to Class 1A EMC Emission

Standards when used with a VLT MICRO.

5.12 ± 0.08(130.0 ± 2.0)

8.66 ± 0.08(220.0 ± 2.0)

7.8 ± 0.04(198.0 ± 1.0)

1.77 ± 0.08(45.0 ± 2.0)

3.94 ± 0.04(100.0 ± 1.0)

0.028(0.7)M4x (3x)

7.87± 0.39(200.0 ± 10.0)

5.12 ± 0.08(130.0 ± 2.0)

8.66 ± 0.08(220.0 ± 2.0)

7.8 ± 0.04(198.0 ± 1.0)

1.77 ± 0.08(45.0 ± 2.0)

3.94 ± 0.04(100.0 ± 1.0)

0.028(0.7)M4x (3x)

7.87± 0.39(200.0 ± 10.0)

5.12 ± 0.08(130.0 ± 2.0)

8.66 ± 0.08(220.0 ± 2.0)

7.8 ± 0.04(198.0 ± 1.0)

1.77 ± 0.08(45.0 ± 2.0)

3.94 ± 0.04(100.0 ± 1.0)

0.028(0.7)M4x (3x)

7.87± 0.39(200.0 ± 10.0)

in (mm)

Dimensions for model 176F7327

Dimensions for model 176F7326

in (mm)

in (mm)

Page 15: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

Drives Solutionstel. 800.432.6367

VLT

® MIC

RO

A

Options – DIN Rail Adapter Bracket Kit

Part Number

230 VAC 176F7311

460 VAC and 230 VAC 1Ø 176F7315

Mounting Screw

Hex NutDin Rail Clip

Adapter

DIN Rail

Hex Nut

Mounting Screw

DIN Rail mounting of the RFI MICRO provides both a secure method of

mounting, as well as easy interchangeability.

Page 16: VLT MICROSeries - tecdriver.com.br MICRO CATALOG.pdf · ® MICROSeries Drives Solutions. tel. 800.432.6367 Contents A 2 Overview and Features A 6 Performance Data A 8 General Technical

tel. 800.432.6367

VLT MICRO Ordering Information

VLT MICRO Model Number

0.5 HP 230 VAC 1Ø UL 176F7300

1 HP 230 VAC 1Ø UL 176F7301

2 HP 230 VAC 1Ø UL 176F7302

0.5 HP 230 VAC 1Ø UL/CE 176F7306

1 HP 230 VAC 1Ø UL/CE 176F7307

2 HP 230 VAC 1Ø UL/CE 176F7308

1 HP 460 VAC 3Ø UL/CE 176F7312

2 HP 460 VAC 3Ø UL/CE 176F7313

3 HP 460 VAC 3Ø UL/CE 176F7314

Options and Accessories Part Number

Remote Keypad Kit

Includes all hardware and 2 m cable 176F7310

Includes all hardware and 5 m cable 176F7325

DIN Rail Adaptor

DIN Rail Adaptor Bracket Kit (230 VAC) 176F7311

DIN Rail Adaptor II Bracket Kit 176F7315

(230 VAC 1Ø CE & 460 VAC)

RFI Filters

200-240 1Ø 176F7327

200-240 3Ø 176F7328

380-480 3Ø 176F7326

Brake Resistors – 230 VAC

0.5 HP 30% Duty Cycle 175U1003

0.5 HP 40% Duty Cycle 175U0900

0.75 HP 20% Duty Cycle 175U1004

0.75 HP 40% Duty Cycle 175U0901

1 HP 14% Duty Cycle 175U1005

1 HP 30% Duty Cycle 175U0989

1 HP 40% Duty Cycle 175U0902

2 HP 15% Duty Cycle 175U0992

2 HP 40% Duty Cycle 175U0903

Brake Resistors – 460 VAC

1 HP 10 or 14% Duty Cycle 175U1001

1 HP 30 or 40% Duty Cycle 175U0982

1 HP 40% Duty Cycle 175U0910

2 HP 15 or 16% Duty Cycle 175U0954

2 HP 40% Duty Cycle 175U0912

3 HP 5 or 9% Duty Cycle 175U0987

3 HP 40% Duty Cycle 175U0913