virtopsy- a review

14
VIRTOPSY- A REVIEW VIRTOPSY- A REVIEW Dr. Arvind Kumar Dr. Arvind Kumar Senior Demonstrator Deptt. Of Forensic Medicine UCMS DELHI-110095

Upload: doria

Post on 20-Jan-2016

25 views

Category:

Documents


0 download

DESCRIPTION

VIRTOPSY- A REVIEW. Dr. Arvind Kumar Senior Demonstrator Deptt. Of Forensic Medicine UCMS DELHI-110095. VIRTOPSY. Coined by Dr. Michael J Thali et al VIRTOPSY= virtual + Autopsy. Essentials of virtopsy. Multi-slice Computed Tomography (MSCT) Magnetic Resonance Imaging (MRI) - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: VIRTOPSY- A REVIEW

VIRTOPSY- A VIRTOPSY- A REVIEWREVIEW

Dr. Arvind KumarDr. Arvind Kumar

Senior Demonstrator

Deptt. Of Forensic Medicine

UCMS

DELHI-110095

Page 2: VIRTOPSY- A REVIEW

VIRTOPSYVIRTOPSY

Coined by Dr. Michael J Thali et al

VIRTOPSY= virtual + Autopsy

Page 3: VIRTOPSY- A REVIEW

Essentials of virtopsyEssentials of virtopsy

Multi-slice Computed Tomography (MSCT)

Magnetic Resonance Imaging (MRI)

Magnetic Resonance Spectroscopy

3-D/ CAD Photogrammetry

Page 4: VIRTOPSY- A REVIEW

Application of VirtopsyApplication of Virtopsy

Atrium Mortis

Relevant forensic patho-morphologic findings

Forensic Vital reactions

Reconstruction of Injuries

Recapitulation and Visualization

Page 5: VIRTOPSY- A REVIEW

Varying density values in a 3D MSCT reconstruction in a case of blunt trauma to the head.

 

Page 6: VIRTOPSY- A REVIEW

3D reconstruction of a skull fracture system from the MSCT data in a case of a motor vehicle accident with the victim

having been run over by a car

Page 7: VIRTOPSY- A REVIEW

Coronal T2 weighted MR image showing wound track

(arrows) through the brain in a suicidal gunshot case

Page 8: VIRTOPSY- A REVIEW

Gadolinium enhanced MRI of patient with lateral wall myocardial infarction. Four chamber view of heart with

bright signal in lateral wall of left ventricle (LV).

Page 9: VIRTOPSY- A REVIEW

Figure showing comparison of spectrum from a human brain with a PMI of about 520 hours (a) and one with a PMI of 57 hours (b)

Page 10: VIRTOPSY- A REVIEW

Merits and DemeritsMerits and DemeritsMerits

* observer independent* reproducible* non invasive* illustrative visualization* forensic telemedicine

consultation

Page 11: VIRTOPSY- A REVIEW

Demerits* MRI was unable to

# image coronary artery lesions # differentiate thrombus from postmortem clot# differentiate pulmonary oedema from pneumonic exudates# detect perinatal cardiac malformations

Page 12: VIRTOPSY- A REVIEW

* lack of validation* interpretative problems in

advanced decomposition

* considerably high costs* time consuming

Page 13: VIRTOPSY- A REVIEW

ConclusionConclusion

The conventional method of Autopsy is still the gold standard

The use of imaging technology should be an autopsy adjunct rather than a replacement

Page 14: VIRTOPSY- A REVIEW

Thank Thank youyou