    Vindon Stability Storage Rooms provide a large volume controlled environment at a cost

    effective price. Modular construction ensures that all panels will pass through a standard

    doorway so installation and any future re-location is straightforward. Both the insulating

    foam and the refrigerant are CFC free.

    All rooms are built and pre-wired at our factory where customers are encouraged to witness

    the final testing. Once approved the rooms are dismantled and delivered to site where our

    own engineers will re-assemble and commission in the shortest possible time.

    The design and build of Environmental Rooms is covered by our ISO 9001 registered quality

    system..

    Walk-in stability storage rooms

  • 8/4/2019 Vindon Stabilty Rooms

    3/4

    Room ShellThe rooms are constructed from self supporting pre-fabricated,

    60mm or 100mm thick panels, which lock together by a cam-

    lock system. The panels comprise of two steel skins that are

    injected with a high pressure, CFC free, polyurethane foam,

    thus creating an insulated sandwich panel.

    The external face of the panels is finished in white 9002 (RAL)

    epoxy coating and the internal skin is finished in grade 316

    stainless steel. This provides a surface that will withstand the

    specified temperature and humidified environments, will not

    rust over time and is easy to clean.

    Room dimensions can be altered in size increments of 300mm

    with regard to height, width and depth.

    Room FlooRThe floor panels are 60mm or 100mm thick, which have been

    injected with CFC polyurethane foam. Floors are finished with

    a layer of anti-slip polyester.

    DooRSThe doors are manufactured from the same materials that are

    used on the wall and ceiling panels. The standard size door

    opening is 650mm wide and 2000mm high, although larger

    dimensions are available. Doors can be either left hand or right

    hand hinge, dependent upon customer specification.

    The doors are fitted with a key operated lock on the outside

    handle of the room. In the event of a person being accidentally

    locked inside, an internal push button device can be operated

    to allow the person to over-ride the door lock and exit the

    room

    Shelving SyStemOur rooms incorporate a bespoke shelving system that is

    designed to fit around our floor mounted ducting system.

    The entire shelving system is manufactured from grade 304

    stainless steel. Shelving uprights are securely fastened in

    place, providing a strong and stable racking design. Perforatedshelving is supported on rods which sit in holes machined into

    the uprights on a 50mm pitch. The height of each shelf can be

    adjusted by placing the support rods in the required position of

    the holes on the uprights. The shelves are perforated to allow

    air to pass through them and onto stored product.

    opeRating ConDitionSVindon Scientific stability storage rooms are generally specified

    to cover the ICH conditions of 25c/60%RH, 30c/65%RH &

    40c/75%RH. Rooms will operate with in the limits of 2c

    and 5%RH. This gives users the flexibility of changing the set

    point of the room should future requirements ever change. We

    can however extend both the temperature and humidity range

    based upon customer specification. We also manufacture 5c

    cold rooms which use direct refrigeration systems rather than

    indirect ones.

    inDiReCt ReFRigeRationOur standard ICH - type stability storage rooms use an indirect

    refrigeration system to help control the internal temperature of

    the room. An ex ternal chiller uses a direct refrigeration system

    to cool a tank of water to a specific temperature directly related

    to the operating set point of the room. This cooled water isthen pumped to a cooling coil that is located in a stainless steel

    plenum at the rear of the room and works together with the

    heaters to provide accurate temperature control.

    The temperature of the coolant is monitored by a sensor and

    controller that switches on the fridge to maintain the required

    water temperature.

    DuCting SyStemWe control the environment of our stability storage room by

    use of a ducting system. This is manufactured from grade

    304 stainless steel. The ducting system comprises of a vertical

    plenum located at the rear of the room within the corridor. Air

    is attracted at high level through this plenum by the fan(s).

    That air is then passed down over the cooling coils and over the

    heaters to floor mounted horizontal ducts where it passes into

    the room through adjustable vents. The floor mounted ducts

    are situated beneath our shelving system

    ConDenSate pumpThe condensate pump is located in the base of the main control

    tower at the front of the room. It collects any condensate that

    has dripped off the coiling coils within the room and also

    any reject water that has been drained from the humidity

    generator. As the water in the pump reaches a float switch, the

    pump is activated and the water is sent to drain.

    light(S)Stability storage rooms are fitted with a fluorescent light(s)

    within the corridor of the room which are activated by an

    on/off switch on the face of the main control tower. A neon

    light on the switch indicates that the light inside the room is

    turned on.

    In the event of mains power failure to the room, the light

    fitting closest to the door is activated via a battery back up

    providing approximately one third of the units normal light

    output. This is sufficient to allow a person within the room to

    exit safely.

    humiDity geneRatoROur stability storage rooms are fitted with a humidity generator

    to provide a controlled level of humidity inside the room.

    The generator is comprised of a stainless steel tank containing

    approximately litre of laboratory grade II water. At the base

    of the generator are two ultrasonic transducers that operate

    at the resonant frequency of water. When the room requires

    humidity, the transducers are energised by the humidity

    control circuit causing the water just below the surface to break

    into tiny droplets forming a cloud above the surface of the

    water. An air supply is taken from the room via flexible tubing

    and passed over the sur face of the water, collecting the cloud

    of water on the way. This humidified air is then returned to

    the room thereby raising the level of humidity inside.

    In order to keep the system working to optimum levels, the

    water inside the generator is rejected down to the condensate

    pump approximately every 6 hours preventing cardboard

    spores carried in the air supply from the room settling in the

    water and causing the equipment to malfunction.

    tempeRatuRe alaRmEach stability storage room is fitted with a temperature alarm

    circuit consisting of an independent controller and sensor.

    The controller is programmed with the high and low alarm

    points for the room. In the event of a temperature alarm, the

    controller will activate both audible and visual alarm indicators

    on the main control tower and will activate a set of volt free

    contacts located within the control tower which can be linked

    to a BMS. Once any fault has been cleared, the circuit will re-set

    automatically. The audible alarms may be muted.

    humiDity alaRmTotally independent alarm system from the temperature alarm

    but operates in exactly the same way

    paniC alaRmOur stability storage rooms are fitted with a panic alarm circuit

    that is activated by one or more push buttons inside the room.

    If an operator were to get into difficulty inside the room, they

    could press the button which would activate an extremely loud

    warning siren and flashing alarm beacon outside the room

    to attract the attention of people in the area. In addition, a

    further set of volt free contacts will be activated which can be

    linked to BMS.

    aSSembly & FaCtoRy aCCeptanCe teSt

    Stability storage rooms are specifically designed to meetcustomer requirements. Each room is designed and

    manufactured at our site in Oldham. Each room is fully

    assembled and tested thoroughly at our premises prior to

    installation. The room is not dismantled until it has passed ou r

    factory qualification requirements. This testing reduces the

    site build time significantly, which in turn reduces the impact

    our work has on our customers day to day business

    We will then make the necessary arrangements to have

    the room dismantled, delivered and installed using our own

    suitably trained staff.

    WaRRantyAll rooms carry a full 12 month parts warranty. After this

    period, we offer a preventative maintenance contract or

    emergency call out assistance.

    Specification

  • 8/4/2019 Vindon Stabilty Rooms

    4/4

    Vindon Scientific Limited

    John Boyd Dunlop Drive, Kingsway Business Park, Rochdale, OL16 4NG

    Tel: +44 (0)1706 716710 Fax: +44 (0)1706 716740 Email: [email protected] Web: www.vindon.co.uk

    Validation

    Stability Storage Rooms

    At a glance

    Vindon Scientific Ltd also offers a comprehensive validation

    package both on newly installed equipment and existing

    equipment. Our service comprises four main areas:-

    is Qfc iQ:- consisting of electrical

    safety inspection and testing, mechanical inspection and

    component checklists.

    or Qfc oQ:- consists of a single-

    point calibration, recording of all controller settings and

    programming, functional testing o f environmental chambers.IQ & OQ are not required on environmental chambers that are

    already in use.

    Cr Qfc CQ:- is the calibration of the data

    logger and probe set to be used in completion for PQ. The test

    probes are placed around the traceable reference probe in the

    middle of the chamber and allowed to settle. After a period

    of time, readings from the traceable probe are compared

    with those from the data logger and test probes. Any error

    of the test probes against the traceable probe is corrected via

    software on the data logger. After the correction the results are

    monitored for a short while to confirm accuracy.

    prfrc Qfc pQ:- consist of multiple-point

    performance mapping of the environmental chambers and

    normally include unloaded, loaded and door open recovery

    tests for new equipment or just loaded (as found) testing of

    existing environmental chambers. The corrected probes from

    the CQ procedure are placed in recorded positions throughout

    the chamber and the data is collected of the performance of

    the chamber at these points. If out of specification readings

    are discovered during the PQ, the validation engineer may

    make mechanical or electrical changes to the equipment toresolve the issue.

    TemperaTure/HumidiTy conTrol

    Accuracy:

    Temperature validatable to +/- 2C

    Humidity validatable to +/- 5%RH

    Alarms:

    Independent alarms for out of spec temperature & humidity

    Volt free contacts for remote alarm notification

    Internal panic alarm

    Build

    Design:

    Custom turnkey solutions to your requirements and room layouts

    Construction:

    Stainless steel interior panel surface & shelving

    Epoxy coated metal exterior

    Self-extinguishing polyurethane insulated panels

    Anti-slip polyester floors

    Lighting:

    Internal occupancy lightingEmergency lighting

    daTa logging:

    Standard strip chart recorder

    21 CFR part 11 compliant data logger (multi-channel)

    insTallaTion and service

    Installation & Validation

    Pre-fabricated panels for quicker setup

    IQ/OQ/PQ/CQ provided upon request

    Care & Assurance:

    Long term maintenance contracts designed to specific client requirements