village of lemont historic preservation commission sion

6
HISTORIC PRESERVATION COMMISSION AGENDA SPECIAL MEETING November 19, 2015 6:30 p.m . LEMONT VILLAGE HALL 418 MAIN STREET I. CALL TO ORDER II. ROLL CALL III. APPROVAL OF MINUTES: Meeting September 3, 2015 IV. CHAIRMAN’S REPORT V. PUBLIC HEARINGS VI. APPLICATIONS A. Certificate of Appropriateness for addition to La Dolce Vita restaurant, 107 Stephen Street. VII. NEW BUSINESS VIII. PLANNING & ECONOMIC DEVELOPMENT DIRECTOR COMMENTS A. National Register Application: Commercial District update. B. St. Patrick School Building IX. AUDIENCE PARTICIPATION X. ADJOURN Village of Lemont Historic Preservation Commission 418 Main Street · Lemont, Illinois 60439 phone 630-257-1595 · fax 630-257-1598

Upload: others

Post on 19-Mar-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

HISTORIC PRESERVATION COMMISSION

AGENDA

SPECIAL MEETING

November 19, 2015 – 6:30 p.m.

LEMONT VILLAGE HALL

418 MAIN STREET

I. CALL TO ORDER

II. ROLL CALL

III. APPROVAL OF MINUTES: Meeting September 3, 2015

IV. CHAIRMAN’S REPORT

V. PUBLIC HEARINGS

VI. APPLICATIONS

A. Certificate of Appropriateness for addition to La

Dolce Vita restaurant, 107 Stephen Street.

VII. NEW BUSINESS

VIII. PLANNING & ECONOMIC DEVELOPMENT DIRECTOR

COMMENTS

A. National Register Application: Commercial District

update.

B. St. Patrick School Building

IX. AUDIENCE PARTICIPATION

X. ADJOURN

Village of Lemont

Historic Preservation Commission sion

418 Main Street · Lemont, Illinois 60439 phone 630-257-1595 · fax 630-257-1598

SH

EE

T N

o.

NB

RE

VIS

ION

SP

LAN

No.

DA

TE:

DR

AW

N B

Y:

SC

ALE

:

AP

PR

OV

ED

BY

:

n. b

atis

tich,

arc

hitec

tsM

EA

DO

WB

RO

OK

OFF

ICE

CE

NTE

R16

W4

75 S

. FR

ON

TAG

E R

D.,

SU

ITE

20

1B

UR

R R

IDG

E, I

L 6

05

27

(63

0) 9

86

-177

3

DO

NO

T S

CA

LE D

RA

WIN

GS

CO

NTR

AC

TOR

SH

ALL

VE

RIF

Y A

LL P

LAN

A

ND

DIM

EN

SIO

NS

AN

D C

ON

DIT

ION

S O

N

THE

JO

B A

ND

SH

ALL

IMM

ED

IATE

LY N

OTI

FY

THE

AR

CH

ITE

CTS

, IN

WR

ITIN

G, O

F A

NY

D

ISC

RE

PA

NC

IES

BE

FOR

E P

RO

CE

ED

ING

W

ITH

WO

RK

OR

BE

RE

SP

ON

SIB

LE F

OR

SA

ME

.

I HE

RE

BY

CE

RTI

FY T

HA

T TH

ES

E P

LAN

S W

ER

E

PR

EP

AR

ED

BY

ME

OR

UN

DE

R M

Y S

UP

ER

VIS

ION

AN

D T

HA

T TH

EY

CO

MP

LY T

O T

HE

BE

ST

OF

MY

KN

OW

LED

GE

AN

D B

ELI

EF

WIT

H T

HE

R

EQ

UIR

EM

EN

TS O

F TH

E B

UIL

DIN

G C

OD

E.

STON E VENEER TO MATCHTHE EXISTING STONE

340 # T EXTURED ASPHALTSHINGLES

COPP ER FLASHING

LIMESTON E SILL TO MATCHTHE EXISTING SILL

FIBE R CEMENT PANELS.FAST EN TO STEEL STUDS

1" L OW- E INSULATED GLASSTRANSOM

12MATCH W/EXISTING

7'-6"

RADIU

S

EXIST ING ADJACENT BUILDING

3'- 6" H IGH METAL GUARDRAILINGSYSTEM

1 1/ 2" D IAMET ER STEEL RAILINGS

1" X 1" STEEL SP IND LES A T 4 3/4" O.C. SPINDLES SHALL BE SPACEDSO T HAT A 4 " ROUND OBJECT CANNOT PASS THROUGH

NEW STO NE VENEER TO MATCHTHE EXISTING

SING LE PLY ROOFING

EXIST ING ADJACENT BUILDING

ALUM INUM G RAVEL STOP. COLOR IS TO MATC H T HAT OF THE ALUMINUMGUTTERS

3'- 0" H IGH METAL RAILING SYSTEMWITH 1 1/2" DIA. RAILS

PROV IDE AN EXPANSION JOINT IN BETWEENTHE NEW AN D EXISTING MASONRY WALL

4" LIMESTONE SILL

SEAML ESS A LUMINUM GUTTERS ANDALUM INUM DOWNSPOUTS

340 # T EXTU RED ASPHALT SHINGLES

ALUM INUM VE NTS. ALSO PLASTIC FLASH AROU ND THE ROOF VENTS

REMOV E TH E EX ISTING GUTTERS AND DOWNSPOUTS AND INST ALL NEW SEAMLESS ALUMINUM GUTTERS AND ALUM INUM DOWNSPOUTS

1212

EXIST ING STONE IS TO REMAIN

LINE OF NEW BUILDINGLINE OF EXISTING BUILDING

ALUMI NUM DRIP CAP. MATCH COLOR WITH TH AT OF THE GUTTERS

NEW STO NE VENE ER IS TO MATCH THE EXISTINGSTON E. ALI GN NEW STONE WITH THAT OF THEEXIST ING STONE

NEW LIME STON E SIL L. MATCH WITH THE EXISTINGLIMES TONE SILL

3'-0"

RADIU

S

EXPOSED COPPER FLASHING

NEW STO NE T O MATCH THE EXISTINGSTONE

EXTERIOR DOORS AND WINDOWS

DOORS:PROV IDE "P ELLA " O R EQ UAL ALUMINUM CLAD FULL LITE COMMERCIAL DOORDOO RS W ITH ALU MINU M CLA D FULL LITE SIDELITES. PROVIDE 1" LOW- ETEMP ERED INSULA TED GLASS FOR THE DOORS AND SIDELITES.

EXTERIOR DOORS AND WINDOWS

VIN YL SIDING

VIN YL SIDING

ALUM INUM CLAD FULL LITECOMMER CIAL DOOR 3'-0" X 7'-0"WIT H ( 2 )- 1'-6" X 7'-0" ALUMINUMCLAD FULL LITE SIDELITES.PROVID E 1" LOW- E TEMPEREDINSU LATE D GLASS FOR THE DOORAND THE SIDELITES.

REUSE TH E EX ISTING WINDOWS THAT WERE REMOVEDFROM THE EXI STING BUILDING IN THE NEW ADDITION

ALL WIN DOW S IN THE EXISTING BUILDINGARE TO REMAIN

LINE OF NEW BUILDING LINE OF EXISTING BUILDING

VERIF Y THE D IMENSION S OF IN- PLACE AND SUBSEQUENT CONSTRUCTION ANDACCUR ATEL Y FI T THIS PART OF THE WORK TO OTHER CONSTRUCTION

PROV IDE TIG HT JOIN TS A ND EFFECTIVELY SEAL THE COMPONENT PARTS OF THEWIN DOW S AN D T HEIR JO INTS TO OTHER WORK AGAINST WATER LEAKAGE ANDAIR IN FILTRATION.

WINDOWSREUSE TH E EX ISTIN G W IND OWS THAT WERE REMOVED FROM THE EXISTING BUILDINGIN THE NEW ADDITION

DOORS:MINU MUM U- FACTOR= .32

REUSE TH E EXISTING WINDOWSTHA T W ERE REMOVED FROMTHE EXISTING BUILDING INTHE NEW ADDITION

EXISTING BUILDING ISTO REMAIN

6" X 6" P RESSURE TREATEDWOO D P OSTS ( 3 TOTAL )COVE RED WITH WOOD 2-PIECECOLUMN

2- 2' -0" X 2'-6" STEELSERVI CE DOORS

EXPA NSIO N J OINT IN BETWEEN THE NEWAND EXI STING MASONRY WALLS

WEST ELEVATION

EAST ELEVATIONSCALE 1/4"- 1'-0"

SCALE 1/4"- 1'-0"

NEW MET AL AWNING IS TO MATCHTHE EXIST ING METAL AWNINGS

SOUTH ELEVATION

NORTH ELEVATIONREMOV E TH E EX ISTING SHINGLES AND FELT PAPER AND IN STALL N EW 30 # FELT PAPER AND NEW 340 #TEXT URED ASP HALT SHINGLES OVER THE EXISTING SHEATHING

1/2" PREMO ULDED EXPANSION JOINT

SEALANT

EXIST ING STONE WALL

CONT INUO US 4" X 4" X 1/4" STEELANG LE W ITH 3/8" DIA. EXPANSIONANCH ORS AT 4'-0" O.C.

SEALANT

NEW MASONRY WALL

EXPANSION JT. DETAILSCALE 1 1 /2" - 1'-0"

SCALE 1/4"- 1'-0"

JUNE

29, 2

015

NB 0

629-

15

A - 3

107 S

tephen

St._

__Lem

ont, IL

Addit

ion to

:La

Dolc

e Vita

SH

EE

T N

o.

NB

RE

VIS

ION

SP

LAN

No.

DA

TE:

DR

AW

N B

Y:

SC

ALE

:

AP

PR

OV

ED

BY

:

n. b

atis

tich,

arc

hitec

tsM

EA

DO

WB

RO

OK

OFF

ICE

CE

NTE

R16

W4

75 S

. FR

ON

TAG

E R

D.,

SU

ITE

20

1B

UR

R R

IDG

E, I

L 6

05

27

(63

0) 9

86

-177

3

DO

NO

T S

CA

LE D

RA

WIN

GS

CO

NTR

AC

TOR

SH

ALL

VE

RIF

Y A

LL P

LAN

A

ND

DIM

EN

SIO

NS

AN

D C

ON

DIT

ION

S O

N

THE

JO

B A

ND

SH

ALL

IMM

ED

IATE

LY N

OTI

FY

THE

AR

CH

ITE

CTS

, IN

WR

ITIN

G, O

F A

NY

D

ISC

RE

PA

NC

IES

BE

FOR

E P

RO

CE

ED

ING

W

ITH

WO

RK

OR

BE

RE

SP

ON

SIB

LE F

OR

SA

ME

.

I HE

RE

BY

CE

RTI

FY T

HA

T TH

ES

E P

LAN

S W

ER

E

PR

EP

AR

ED

BY

ME

OR

UN

DE

R M

Y S

UP

ER

VIS

ION

AN

D T

HA

T TH

EY

CO

MP

LY T

O T

HE

BE

ST

OF

MY

KN

OW

LED

GE

AN

D B

ELI

EF

WIT

H T

HE

R

EQ

UIR

EM

EN

TS O

F TH

E B

UIL

DIN

G C

OD

E.

2'-0" 5'-6" 5'-5" 1'-0"

5"9'-

0"10

'-7"

4'-4"

1'-7" 3'-9"

4'-5 1

/2"8'-

3"4'-

5 1/2"

1'-10"

2'-4"

7"15'

-7"

7" 7'-0" 5"

5" 13'-0"

5" 9'-0" 5" 3'-6"5" 7'-6"

1'-0"

6'-6"

7"3'-

10"

5'-8"

7"

7" 5'-10" 5" 5'-4" 1'-0"

2'-0"1'-0"

1'-0"

3'-8"

5"8'-

4"5"

3'-9"

7"13'

-0"

1'-2"

8'-2"

5" 11'-0" 5'-6" 6'-7" 1'-0"

2'-0" 5'-6" 5'-0"

7'-6"

5'-6"

1'-0"

1'-0"

26'-8" 1'-0"

27'-8"

8"8'-

3"

15'-0" 3'-10" 5" 7'-5" 1'-0"

32'-4

"

4'-0" 18'-8"

22'-8" 5'-0"

17'-2"

15'-2

"

2'-0" 5"

32'-4

"

7'-10" 5" 8'-3" 5" 9'-9"

5" 1'-2" 12'-7" 1'-0"

4'-0" 13'-9" 4'-6"

27'-8"

17'-2"

15'-2

"

5'-6" 5'-9"

2'-0" 5"

7"13'

-0"

1'-'2"

1'-0"

5'-2"

6'-5"

5'-0"

7"

5'-4" 1'-0"7" 5'-10" 5"

1'-0"

3'-8"

5"8'-

4"5"

3'-9"

5'-0"22'-8"

4'-9"

5"7'-

10"

9'-10

"3'-

2"

1'-0"

A6

R

BANQUET ROOM LEVEL FLOOR PLANSCALE 1/4"- 1'-0"

NOTE

104

A7

A6

WAIT STATION

A6 NOTECOM PLETE KITCHEN DRAWINGS TOBE S UBMIT TED FOR APPROVAL BY"TR IMARK" F OOD SERVICE EQUIPTMENT SUPPLI ES AND DESIGN

WAIT STATION105

KITCHEN103

KITCHEN

A7

NOTE

RESTAURANT LEVEL FLOOR PLAN

"B"

"B"

ENTRY

WAIT STATION

EXIST ING STAIR TO REMAIN

EXIST ING BAR IS TO REMAIN

101 102FOYER

RESTAURANT SEATING AREA

EXISTING

EXIST ING IS TO REMAIN

BAREXIST ING IS TO REMAIN

EXIST ING STAIR TO REMAIN"A"

EXIST

ING

2,500 lb.ELEVATOR

DN 22RWOOD

BAREXIST ING IS TO REMAIN

EXIST ING BAR IS TO REMAIN

BANQUET ROOMEXIST ING IS TO REMAIN

EXIST ING STAIR TO REMAIN

ALL EXI STING BE AMS AND COLUMNSARE TO REMAIN

SMOOT H FI BERG LASS ( F.R.P.) .030"LAMIN ATED TO 5/8" GYPSUM BOARD TOGO OVER THE EXISTING WALL

ALIGN NEW WALLW/ E XISTING WALL

PATCH STONEWALL AS REQUIRED

EXIST

ING S

TRUC

TURE

A6

DUCTCHASE

HOSTESS

PATCH STONEWALL AS REQUIRED

EXPOSED STONEWALL I S TO REMAIN

DUCTCHASE

EXPOSED STONEWALL I S TO REMAIN

BANQUET RM.ENTRANCE

201

FINAL PREP

204

3'-0" HIGH X 7'-0" HIGHCASE D OPENING

EXIST

ING S

TRUC

TURE

IS TO

REMA

INEXISTING

IS TO

REMA

INEX

ISTING

STR

UCTU

REIS

TO RE

MAIN

4-YARDDUMPSTERENCLOSURE

SCALE 1/4"- 1'-0"

2,500 lb.ELEVATOR

A4 A4

P

A5A5

DN 12

R

A6

1-1

LEGEND

5/8 " GYPSUM BOARD2X 4 WO OD STUDS AT 16" O.C. OR2 X 6 W OOD STUDS AT 16" O.C.5/8 " GYPSUM BOARD

5/8 " FI RECODE GYPSUM BOARD2 X 4 W OOD STUDS AT 16" O.C. OR2 X 6 W OOD STUDS AT 16" O.C.5/8 " FI RECODE GYPSUM BOARD

1 HO UR R ATED PARTITION WALLU.L. DESIGN NO. U 305

EXPANS ION JOINT

SMOOTH FIBERGLASS ( F.R.P.) .030"LAMINAT ED T O 5/ 8" GYPSUM BOARD TOGO O VER THE EXISTING WALL

PRIVATE ROOM106

COMP LETE DRAW INGS FOR THE PREP AREA ( 104 )AND DIS HWASHI NG ARE A ( 10 8 ) ARE TO BE SUBMITTEDFOR APPRO VAL BY "TR IMARK" FOOD SERVICE EQUIPTMENTSUPPLI ES AND DESIGN

PREP AREA

DISHWASHING AREA108

107CORRIDOR

( F.R. P.) .0 30" L AMINATED TO 5/8" GYPS UM BOARD TO GO OVERTHE EXI STING WALL

PRO VIDE A NE W PARTITION WALL INTHE VOI D WHERE THE DOOR WAS REMOVED

4" C ONCRETESLAB

3'- 0" HIGH METALRAILI NG SYSTEM

"B"

UP 22R

"C"

O

5'- 0" CASED OPENING IN TH E EXISTING WALL

3'-6" HIGH GUARDRAILINGSYSTEM

5'- 0" X 7'-0" CASEDOPENING

WOMEN'S TOILET RM MEN'S TOILET RM203 202

STON E IS TO B E SET BT THE MASON CONTRACTOR IN ACCORDANCEWITH SH OP AND SETTING DRAWINGS.

ALL ANCH ORS A ND ANCH ORING DEVICES SHALL BE FURNISHED BY THE MASON CON TRACT OR AS SHOWN ON THE APPROVED SHOP DRAWINGS

SMOOT H FI BERG LASS ( F.R.P.) .030"LAMIN ATED TO 5/8" GYPSIM BOARD

4" STON E TO MATCH EXISTING8" CONC RETE CLOCKDUR - O - WAL TRUSS TYPE WALLREINF ORCEM ENT AT 16" O.C.2 X 3 W OOD STUDS AT 16" O.C.2 1/2 " TH ICK EXTRUDED POLYSTYRENE RIGIDFOAMBOARD WITH A VAPOR BARRIERTO THE ROOM SIDE ( R- 13.4 )5/8 " GYPSUM BOARD

4" STON E VE NEER TO MATCH EXISTING1" A IR SPACETYV EK COM MERCIALWRAP1/2" EXTE RIOR PLYWOOD SHEATHING2 X 6 W OOD STUDS AT 16" O.C.R- 1 9 B ATT INSULATION WITH A VAPORBARR IER O N THE WARM SIDE5/8 " GYPSUM BOARD

EXIST ING STO NE WALLS ARE TO REMAIN2" X 2" W OOD FUR RING STRIPS AT 16" O.C.SMOOT H FI BERG LASS ( F.R.P.) .030"LAMIN ATED TO 5/8" GYPSUM BOARD

EXIST ING STO NE WALLS ARE TO REMAIN

"D"

UP 7R

"D"

N

K J

O

Q

M L 6" X 6" P RESSURE TREATEDWOO D P OSTS ( 3 TOTAL )COVE RED WITH WOOD 2-PIECECOLUMN

JUNE

29, 2

015

NB 0

629-

15

A - 2

107 S

tephen

St._

__Lem

ont, IL

Addit

ion to

:La

Dolc

e Vita

SH

EE

T N

o.

NB

RE

VIS

ION

SP

LAN

No.

DA

TE:

DR

AW

N B

Y:

SC

ALE

:

AP

PR

OV

ED

BY

:

n. b

atis

tich,

arc

hitec

tsM

EA

DO

WB

RO

OK

OFF

ICE

CE

NTE

R16

W4

75 S

. FR

ON

TAG

E R

D.,

SU

ITE

20

1B

UR

R R

IDG

E, I

L 6

05

27

(63

0) 9

86

-177

3

DO

NO

T S

CA

LE D

RA

WIN

GS

CO

NTR

AC

TOR

SH

ALL

VE

RIF

Y A

LL P

LAN

A

ND

DIM

EN

SIO

NS

AN

D C

ON

DIT

ION

S O

N

THE

JO

B A

ND

SH

ALL

IMM

ED

IATE

LY N

OTI

FY

THE

AR

CH

ITE

CTS

, IN

WR

ITIN

G, O

F A

NY

D

ISC

RE

PA

NC

IES

BE

FOR

E P

RO

CE

ED

ING

W

ITH

WO

RK

OR

BE

RE

SP

ON

SIB

LE F

OR

SA

ME

.

I HE

RE

BY

CE

RTI

FY T

HA

T TH

ES

E P

LAN

S W

ER

E

PR

EP

AR

ED

BY

ME

OR

UN

DE

R M

Y S

UP

ER

VIS

ION

AN

D T

HA

T TH

EY

CO

MP

LY T

O T

HE

BE

ST

OF

MY

KN

OW

LED

GE

AN

D B

ELI

EF

WIT

H T

HE

R

EQ

UIR

EM

EN

TS O

F TH

E B

UIL

DIN

G C

OD

E.

NORTH

32'-4

"

27'-8" 10"

EXIST ING 2 STORY BUILDINGW/ BASEMENT

S T E

P H

E N S

T R E

E T

T A L C O T T A V E N U E

100.00'

100.00'

32.34

'

32.34

'

20 FT.PUBLICALLEY

GUARDRAIL

TRASHENCL.

PROPOSED 2 STORY ADDITIONW/ BASEMENT

SITE PLAN SCALE : 1/16" = 1-0"

LIST OF DRAWINGS

C1 SITE PLAN

D1 DEMOLITION PL AN AND NOTES

A1 FOUNDATION AND BASEMENT PLANS

A2 RESTAURANT LEVEL AND BANQUET LEVEL FLOO R PLANS

A3 ELEVATIONS

A4 WALL SECTIONS

A5 WALL SECTIONS

A6 WALL SECTIONS

A7 WALL SECTIONS AND TOILET ELEVATIONS

A8 DOOR SCHEDULE AND ROOM FINISH SCHEDULE

S1 STRUCTURAL PLANS

S2 STRUCTURAL DETAILS

P1 PLUMBING P LAN

P2 PLUMBING DIAGRAMS AND NOTES

E1 ELECTRICAL PLAN

E2 ELECTRICAL NOTES

M1 MECHANICAL PLAN

M2 MECHANICAL NOTES

EXIT DOOR NOTETHE EGR ESS SIDE O F THE EXI T DOORS ARE TO OPERATE WITHOUT THE USE OF A KEY, TOOL, SPECIAL KNOW LEDGE , OR EFFO RT FOR OPERATION FR OM THE INSIDE OF THE BUILDING. EGRESS DOORS SHALL BEOPERABLE WIT H NO MOR E THAN ONE RE LEASI NG OP ERATION. THUMBTURN DEAD BOLTS ARE NOT PERMITTED.

ALL EXI STING EXI T DOO RS ARE TO REMAIN WITH NO CHANGES

THE NEW AD DITI ON IS TO BE E QUIPPED W ITH AN APPRO VED FIRE ALARM SYSTEM THAT SHALL BE CONNECTED TO THE EXISTING FIR E ALAR M PANE L. FIR E ALAR M SYS TEM IS T O INCLUDE PULL BOXES AT EXIT DOOR, AUDIO VISUAL FIRE ALARMSIGNALLING D EVI CES AS NE EDE D. SYS TEM IS T O BE DES IGNED IN ACCORDANCE WITH N.F.P.A. 72 CODE REQUIREMENTS.THE I NSTALLI NG CO NTRAC TOR SHALL S UBMIT PLANS T O THE LOCAL FIRE PROTECTION DISTRICT FOR APPROVAL PRIORTO INS TALLATION.

THE P LANS AND S PEC IFIC ATIONS OF THE AUTOMATIC SPRI NKLE R FOR THE NEW ADDITION SHALL BE SUBMITTED TO THE LOCALFIRE PRO TEC TION DIST RIC T FOR APPRO VAL PR IOR TO INSTALLATION BY THE INSTALLING CONTRACTOR. THE SUBMITTALSHALL BE IN ACC ORDANCE W ITH N.F .P.A. 13, CHAPTER 13.

PROVIDE AN APPR OVE D CO MPLIMENT O F 40 BC FI RE EXTINGUISHERS WITH 10 BC EXTINGUISHERS POSITIONED EVERY 50 FEET THE LOCATIONS SHALL BE APPRO VED BY THE LOCAL FIRE PROTECTION DISTRICT.

MEANS OF E GRE SS, I NCLUDI NG THE EXI T DIS CHARGE, S HALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVEDBY ME ANS OF EGR ESS IS O CCUP IED . IN T HE E VENT OF POWER FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMAT ICALLY ILLUMI NATE T HE MEANS OF E GRESS FOR NOT LESS THAN 90 MINUTES.

FIRE NOTES

ALL FLOO R FI NISHES SHALL HAVE A FLOOR SPREAD RATING OF 75 OR LESS

ALL INTE RIO R FINISHE S ON ALL EX TER IOR SURFACES ARE TO HAVE A SMOKE DEVELOPED RATING OF LESS THAN 450WHEN TEST ED I N ACCO RDANCE WITH ASTM E84.

ALL WO RK IS TO CO NFOR M TO THE REQ UIRE MENT S WI THIN C URRENT EDITIONS OF ALL LOCAL, STATE, AND FEDERAL APPLICABLECODES ADOPTED B Y THE LOCAL JURISDICTION.

EACH TRAD E SHALL BE HELD RE SPON SIBLE FOR THE KNOWLEDGE OF THE CONSTRUCTION DOCUMENTS AND THEAPPLICABLE BUILDING CODES.

ALL EXI T AND E MER GENC Y LIGHT ING AR E TO REMAIN THROUGHOUT THE BUILDING

ALL EXI STING POR TABLE F IRE EXTI NGUIS HER S ARE TO REMAIN THROUGHOUT THE BUILDING

GENERAL NOTESVER IFY ALL DI MENS IONS AND CO NDITI ONS I N THE FIELD AND NO TIFY THE ARCHITECT OF ANY DISCREPANCIES WITH THE EXISTINGBEFO RE THE CONT RACTOR PROCEEDS WITH THE WORK

ALL INTE RIO R FINISHES FOR THE W ALLS AND CEI LING ARE TO HAVE A FLAME SPREAD RATING OF 26 TO 75

THE CONT RACT OR SHALL I NCLUDE ALL OW NER FURNI SHED AND INSTALLED ITEMS AND OWNER FURNISHED AND CONTRACTORINSTALLED I TEMS IN THE CO NSTR UCTION AND SHALL COORDINATE WITH THE OWNER TO ACCOMODIATE THESE ITEMS

ALL HAZAR DOUS MATE RIALS THAT ARE STORED ON T HE PREMISES NEEDS TO PROVIDE THE AMOUNTS AND MATERIAL DATA FOR EACH

PROJECT SUMMARY TABLE

REAR 2 S TOR Y ADDIT ION PLUS A BASEMENTSCOPE OF WORK

USE GROUPGRO UP A- 2

CLASS II

FIRE SUPPRESSION/ DETECTION SYSTEM

OCCUPANT LOAD

FIRE SUPPR ESS ION / DETECTION SYSTEM / FIRE ALARM

TYPE V - B

CLASSIFICATION OF INTERIOR FINISHES

CONSTRUCTION TYPE

PROJECT LOCATION

AREA OF ALTERATIONS

107 STEPHEN S T. LEMONT, IL.

EXIS TING AR EA 6,206 SQ. FT.PROP OSE D ADDIT ION 2,434 SQ. FT.TOTAL BUILDI NG ARE A 8,640 SQ. FT.

RES TAURANT 170 OCCUPANTSKITC HEN/ D ISHW ASHING 4 OCCUPANTSSTORAGE 6 OCCUPANTSTOTAL 1 80 OCCUPANTSFINAL O CCUPANT LO AD IS TO BE POSTED

AN ADDITION TO:

107 Stephen St. Lemont, IL

La Dolce Vita

ADOPTED BUILDING CODES FOR L EMONT200 6 INT ERNATIONAL BUILDING CODE200 5 NATI ONAL ELECTRICAL CODE200 6 INT ERNATIO NAL MECHANICAL CODE201 4 ILLI NOIS PLUMBING CODE200 6 INT ERN ATIO NAL PROPERTY MAINTENANCE CODE1997 ILLINO IS ACCESSIBILITY CODE 201 2 IN TER NATIO NAL ENERGY CONSERVATION CODELEMO NT UNI FIED DEVELOPMENT ORDINANCE

CONTRACTORS USE OF THE SITEASSUME FULL R ESPO NSIBI LITY FO R PR OTE CTIO N AND SAFEKEEPING OF PRODUCTS THAT WILL BE STORED ON THE PREMISES.

THE C ONTR ACTOR SH ALL MAINT AIN ADE QUATE SER VIC E PAR KING , AND ACCESS TO THE TENANT SPACE AND THE ADJACENT SPACES.

THE CONT RACTO R SH ALL TAKE ALL PE RCAUT IONS TO PROTECT THE OWNERS PROPERTY FROM DAMAGE DURING THE PROGRESS OF THE WOR K. AN Y DAMAGE TO THE OWNE RS PROP ERT Y SHALL BE R ESTORED OR REPLACED BY THE CONTRACTOR AT HIS OWN EXPENSE ANDIN A MANN ER S ATISFACTORY TO THE OWNER.

CLEAN UPTHE P REM ISE S AND THE JO B SIT E SHALL BE M AINTAI NED I N A RE ASONABLY NEAT AND ORDERLY CONDITION, AND KEPT FREE FROMACCUMULATIO NS OF WASTE MATERI ALS AND R UBBIS H DURI NG THE ENTIRE CONSTRUCTION PERIOD. REMOVE CRATES, CARTONS,AND OT HER FLAMMABL E W ASTE MATE RIALS FRO M THE WORK AREA AT THE END OF EACH WORKING DAY.

NOTESALL EXI TS AND T HEIR CO MPONE NTS S HALL BE PRO PER LY IDE NTIFI ED BY ILLUMINATED SIGNS WITH EMERGENCY BATTERY BACKUP CAPABI LITI ES. ADDIT IONAL DEV ICE S MAY B E REQU IRE D DEP ENDING ON THE FINAL FLOOR LAYOUT. THESE SHALL BE FIELD VERIFIED.

EME RGE NCY LIGHTING UNITS SHALL BE PROV IDED FOR ALL EXI TS AND THEIR COMPONENTS THROUGHOUT THE ENTIRE SPACE. ADDITIONAL DEV ICE S MAY BE R EQU IRE D DEPENDI NG ON THE FINAL FLOOR LAYOUT. THESE SHALL BE FIELD VERIFIED.

ALL EXI T DOO RS AR E TO BE E QUIPPRD W ITH HARDWARE THAT I S EASILY OPENABLE FROM THE DIRECTION OF EXIT TRAVEL WITHOUT THE USE OF K EYS OR SPEC IAL KNOWLE DGE. ANY DE ADBOLT LOCK S MUS T BE EQUIPPED WITH THUMBTURNS ON THE INSIDE OF THE DOOR. THE HARDW ARE SHALL HAV E A S HAPE T HAT IS EASY TO G RASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWIS TING O F THE WRIST TO OPERATE.

OCC UPANT LO ADS SHALL BE POSTED

ALL RO OMS AND AREAS S HALL BE ADEQ UATELY PROTEC TED BY THE BUILDI NG'S AUTOMATIC SPRINKLER SYSTEM. CONTRACTOR SHALL SUBMIT PLANS, HYDRAUL IC C ALCULATI ONS AND CUT SHE ETS TO BOTH AGENCIES FOR REVIEW AND APPROVALS.

BUILDI NG FIR E ALAR M AND DE TEC TION SYSTEM SHALL BE UPGRADED W ITH THE PROPER NUMBER OF DEVICES. CONTRACTOR SHALL SUBMITPLANS, B ATTER Y CALC ULATIO NS, AND CUT S HEE TS TO BOTH AGENCIES FOR REVIEW AND APPROVALS.

A FIXE D EXT INGUI SHING SYS TEM SHALL BE PRO VIDED FO R ALL C OOKING SURFACES AS SPECIFIED BY THE INTERNATIONAL FIRE CODE CHAPTE R 9, NFPA ST ANDARD 96, AND U.L. 30 0. PLAN S AND C UT SHE ETS SHALL BE SUBMITTED TO BOTH AGENCIES FOR REVIEW AND APPROVAL.

A CLASS "K " PO RTABLE FIRE E XTINGU ISHE R SH ALL BE PROVIDED IN THE KITCHEN "PREP" AREA.

PORTABLE FIRE EXTI NGUISHERS WI TH A 4A60BC SHALL BE PROVIDE D AND PROPERLY HUNG WITHIN 5 FEET OF A DESIGNATED EXIT DOOR. ADDITI ONAL UNI TS MAY BE R EQU IRE D DEP ENDING ON THE FINAL FLOOR LAYOUT.

ALL ACCE SSIBLE S IGNAGE SHALL B E IN ACCO RDANC E WI TH A.N.S .I. 4 - 28 - 5 AND THE ILLINOIS ACCESSIBILITY CODE. ACCESSIBLE SIGNAGE

FIRESTOPPING NOTESSEAL ALL PENE TRATI ONS IN THE 1 HO UR R ATED F IRE BARR IER WALL AFTER INSTALLATION OF CONDUIT BOXES, ETC. WITH ANAPPRO VED FIRE- S TOP C OMPO UND. "H ILTI" FS- ONE FLEXI BLE FIRESTOP SEALANT, U.L. SYSTEM NO. W-L- 1054 OR SIMILAR.

JUNE

29, 2

015

NB 0

629-

15

C - 1

107 S

tephen

St._

__Lem

ont, IL

Addit

ion to

:La

Dolc

e Vita

Planning & Economic Development Department Form 210 1

TO: Historic Preservation Commission FROM: Adewale Adetunji, Village Intern THRU Charity Jones, AICP, Planning & Economic Development Director SUBJECT: Nomination for Registration of Historic Places DATE: November 6, 2015 SUMMARY

Staff have been working on an application to the National Register of Historic Places. While the full Lemont Historic District would not qualify for National Register listing, it appears that a portion of the current Lemont Historic District would qualify because the smaller area has enough historical integrity and is locally significant for its commercial history and as well as its full collection of commercial architecture. The purpose of nominating our historic district to the National Register is to give our property owners within the historic district financial benefits and incentives for being in the district. Owners of properties within a listed National Register district may be eligible for a 20% investment tax credit for the certified rehabilitation of income-producing certified historic structures. Federal tax deductions will also be available for charitable contributions for conservation purposes of partial interests in historically important land areas or structures. There will also be opportunities for the village to apply for federal grants for historic preservation.

Additionally, National Register listing means that state or federally permitted/ funded/ licensed projects would be required to examine alternatives before potentially damaging or destroying registered places. The following page contains a map of the area to be included in the National Register application.

Village of Lemont Planning & Economic Development Department

418 Main Street · Lemont, Illinois 60439 Phone 630-257-1595 · fax 630-257-1598

Planning & Economic Development Department Form 210 2

Now that the area for nomination in the National Register has been established, the next step in the application process is to gather information on the individual buildings within the nominated area. To clarify the exact buildings that are being nominated, the village intern recorded pictures of each building being considered. 64 buildings are currently under consideration for inclusion in the district nomination. These photographs will also be added to the application’s required photo log section. Information on the latitude and longitude will be added after receiving the information from the resources of “Google Earth”. Finally, the total area the district needs to be provided as well as a clearly defined boundary description. At the HPC meeting staff will present photos of each building to be included in the nomination package, and the corresponding historical and architectural information for each from the Granacki survey. Any additional information that the HPC can provide related to the buildings will assist staff in the application process.

Figure 1: Area Proposed for National Register Nomination