vi-116

Upload: ufuk-akguel

Post on 04-Apr-2018

223 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/30/2019 vi-116

    1/9

    Unicont SPb Ltd

    VDR/SVDR VHF-station interfaceVI-116

    Technical Documentation

    (116-1-24012011)

    St. Petersburg2011

  • 7/30/2019 vi-116

    2/9

    Unicont SPb Ltd Technical Documentation VI-116

    Page 2

    Table of Contents

    1. PURPOSE..........................................................................................................................3

    2. DELIVERY SET...............................................................................................................3

    3. SPECIFICATIONS ..........................................................................................................3

    4. DEVICE INSTALLATION.............................................................................................3

    5. PRINCIPLE OF DEVICE OPERATION ......................................................................5

    6. DEVICE SETTING..........................................................................................................6

    7. VI-116 CONNECTION TO SCANTY VHF STATIONS .............................................7

    8. WARRANTY ....................................................................................................................8

    9. DATE OF PACKING.......................................................................................................9

    10. ACCEPTANCE DETAILS..............................................................................................9

    11. DATE OF COMMISSIONING .......................................................................................9

  • 7/30/2019 vi-116

    3/9

    Unicont SPb Ltd Technical Documentation VI-116

    Page 3

    1.Purpose

    Device VI-116S/F is intended for connection of voyage data recorder or simplifiedvoyage data recorder with the VHF stations types Sailor RT-2048 (Debeg 6348, Husun 2048),

    Sailor RT-4822 (Debeg 6322, Husun 4822, Sperry 4822, Scanti VHF 1000 DSC), Furuno FM-

    8500.

    2.Delivery Set

    1. VI-116 1 piece2. Operation manual 1 piece3. Cable:

    VI-116S (Sailor)VI-116F (Furuno)

    3.Specifications

    Supply voltage 10..36 VDC

    Power consumption 500 mW

    Maximum analog output power 100 mW

    Maximum analog output amplitude 10 V

    Reproducible frequency band 100 Hz 15 kHzOverall dimensions (casing) 104,5 x 178,5 x 48,5 mm

    Working temperature range -20...70

    VI-116S/F passed all tests for compliance with the standard IEC 60945 (test protocols

    No. 0212/1- of 12.02.07, No. 0302/1- of 02.03.07) and is considered as meeting the

    requirements of IEC standard 60945 and resolution of International Maritime Organization

    .694 (17)

    4.Device installation

    The device is made in a metallic ase for the installation on a vertical vessel bulkhead

    or chassis. The special holes in the case is inteded for the device installation (see Figure 1).

    It is recommended to install the device in the following sequence:

    1) prepare the place for installation on the vessel bulkhead or chassis according to the

    outline device drawing near the VHF station (see Figure 1);

    2) remove the cover of device and fasten the case on the vessel bulkhead or chassis;

    3) disconnect the cable of a handset from radio station and connect it with the terminal

    PHONE on a PCB of VI-116;4) connect the cable with a free terminal on the station instead of hand set; the other

    cable end is to be connected with the terminal RT on the PCB of VI-116;

  • 7/30/2019 vi-116

    4/9

    Unicont SPb Ltd Technical Documentation VI-116

    Page 4

    5) when using the device with the radio station RT-4822/FM-8500, supply the power

    from 10 to 36 VDC to the slot +12 V on the board VI-116. When connected to the radio

    station RT-2048, the external current source is not required;

    6) connect the cable from voyage data recorder with the slot Audio Out of the board

    VI-116, at that the positive lead is to be connected to the outlet +, and the negative lead to

    the outlet - or GND depending on the required signal amplitude (when connected to the

    outlet GND the output signal amplitude becomes two times less than the amplitude set by thejumpers J6, J7, J8 and J9);

    7) set the jumpers in accordance with the connected radio station (see Section 6) and

    supply the power;

    8) check the serviceability of VI-116 and install the cover.

    Figure 1 Outline drawing.

  • 7/30/2019 vi-116

    5/9

    Unicont SPb Ltd Technical Documentation VI-116

    Page 5

    Figure 2 VI-116 connection drawing and location of jumpers on PCB.

    5.Principle Of Device Operation

    The device receives the audio signals from the inputs PHONE and RT, then the

    received signals are amplified by a built-in analog amplifier and are transferred to the output

    AUDIO OUT.

    10..36VDC

  • 7/30/2019 vi-116

    6/9

    Unicont SPb Ltd Technical Documentation VI-116

    Page 6

    6.Device Setting

    Before the first device switch on it is necessary to select a type of radio station to be

    toggled on using the jumpers J1, J2, J3, J4, J5, J10, J11, J12.

    Set the jumpers according to the following table:

    Group MIC Group TLF

    J1 J2 J3 J4 J5 J10 J11 J12J13

    RT-4822 (Sailor) X X 4822

    RT-2048 (Sailor) X X 2048

    FM-8500 (Furuno) X X

    X jumper is set, empty cell jumper is not set.

    2048 4822 position of jumper according to the mark on the board.

    For usage with the different types of voyage data recorders (simplified voyage data

    recorders) a possibility of stepped adjustment of output signal level of -6 dB, 0dB, +6dB is

    realized in VI-116. The required jumpers position is to be selected after verification with the

    documentation for voyage data recorders (simplified voyage data recorders) (parameters).

    10..36VDC

  • 7/30/2019 vi-116

    7/9

    Unicont SPb Ltd Technical Documentation VI-116

    Page 7

    7.VI-116 Connection To SCANTY VHF Stations

    There is additional audio output on the bottom of SCANTY VHF station handset. Toconnect VI-116 execute following operations:

    1. Connect VI-116 to SCNATY additional audio output with shielded wire (see.

    diagram)

    2. Jumper of the MIC group set to position J3.

    3. Short 1-st and 2-nd pins of the RT terminal.

    Holdertube

    TubeRadio station

    Power10/36 VDC

  • 7/30/2019 vi-116

    8/9

    Unicont SPb Ltd Technical Documentation VI-116

    Page 8

    8.Warranty

    The manufacturer guarantees the unit VI-116 complies with this manual provided thatthe operation, transportation and storage conditions are adhered to during the warranty period.

    The units warranty period expires 24 months from the date of its shipping from the

    manufacturers storehouse.

    Within the warranty period, the owner is entitled for a free repair, or a replacement of a

    separate part, provided that the malfunction occurred through the manufacturers fault.

    Warranty repair is provided if the unit is submitted with the manufacturers label and a

    legible serial number available on it, as well as this operating manual.

    The manufacturer is not responsible and cannot guarantee the units operation:

    1. After the warranty period is over;

    2. In case of the failure to observe the units operation, transportation, storage andinstallation rules and conditions;

    3. If the unit is in an unmarketable condition, or has a damaged body, and other causes

    beyond the manufacturers control;

    4. If self-made electrical devices were used.

    5. If there was an attempt to repair the unit by a person who is not an authorized

    representative of the manufacturer.

    If the owner loses this operating manual or the manufacturers label with a serial

    number, the manufacturer shall not provide their copies, and the owner shall be divested of the

    right for a free repair during the warranty period.

    Upon the warranty expiry, the manufacturer shall facilitate the repair of the unit at the

    owners expense.

    Note: in case of warranty repair, the units disassembling from the installation site and

    its delivery to the manufacturers service center are done at the owners expense.

    Visit the manufacturers website www.unicont.spb.ru (section support/warranty) to

    find:

    forms to fill in claims, full warranty description; full description of the warranty service rendering procedure.

    The manufacturer service centers address and contact details:

    Unicont SPb, Ltd.

    Bld. 26 Kibalchich Str., Saint Petersburg, 192174, Russia

    tel.: + 7 (812) 622 23 10, +7 (812) 622 23 11

    fax: +7 (812) 362 76 36

    e-mail: [email protected]

  • 7/30/2019 vi-116

    9/9

    Unicont SPb Ltd Technical Documentation VI-116

    Page 9

    9. DATE OF PACKING

    VDR/SVDR VHF-station interface VI-116 name of article designation serial number

    Packed Unicont SPb Ltd., Russia.Manufacturer

    according to the requirements of the current technical documentation.

    post signature clarification of signature

    year, month, day

    10. ACCEPTANCE DETAILS

    VDR/SVDR VHF-station interface VI-116 name of article designation serial number

    was manufactured and accepted in accordance with the regulatory requirements of the

    state standards and applicable technical documentation, and is suitable for operation.

    Quality control representative

    Stamp

    here signature clarification of signature

    year, month, day

    11. DATE OF COMMISSIONING

    VDR/SVDR VHF-station interface VI-116 name of article designation serial number

    The unit has been put into operation.

    Date of installation: _________________________________________

    Place of installation: _________________________________________

    Person in charge of installation: _________________________________________