15
UHDE-STANDARD UN 2004-06 (M) Vessels and equipment INSULATION CLIPS FOR VERTICAL STEEL VESSELS Page 2 of 2 3 Clips for cold insulation rated down to -140°C All dimensions in mm Figure 2. 4 Requirements 4.1 Design Clips shall be attached to the shell by circumferential fillet welds (a = 3 mm). Clips and rings shall not be welded onto longitudinal and circumferential welds. Rings across longitudinal welds shall be cut out appropriately. Clips and rings shall not be welded at the same level as nozzles, openings and platform supports. Partly insulated vessels shall be equipped with a circumferential 6 mm thick flat bar ring at the upper end (width = insulation thickness). 4.2 Materials Clips welded to the vessel shall be made of the same material as the vessel. Clips welded to other components of the vessel, such as the skirt, shall be made of the same material as the component.

Upload: buidung

Post on 06-Feb-2018

240 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement

UHDE-STANDARD UN

2004-06 (M)

Vessels and equipment

INSULATION CLIPS

FOR VERTICAL STEEL VESSELS Page 2 of 2

3 Clips for cold insulation rated down to -140°C All dimensions in mm

Figure 2.

4 Requirements

4.1 Design Clips shall be attached to the shell by circumferential fillet welds (a = 3 mm).

Clips and rings shall not be welded onto longitudinal and circumferential welds. Rings across longitudinal welds shall be cut out appropriately.

Clips and rings shall not be welded at the same level as nozzles, openings and platform supports.

Partly insulated vessels shall be equipped with a circumferential 6 mm thick flat bar ring at the upper end (width = insulation thickness).

4.2 Materials Clips welded to the vessel shall be made of the same material as the vessel. Clips welded to other components of the vessel, such as the skirt, shall be made of the same material as the component.

Page 2: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement
Page 3: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement
Page 4: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement
Page 5: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement
Page 6: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement
Page 7: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement
Page 8: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement

UHDE-STANDARD UN

2000-07 Part 1 (M)

Vessels and Equipment

LIFTING LUGS AND LIFTING TRUNNIONS for erection of steel vessels Page 1 of 5

[Modified On: 29/08/2008]

© 2008 UHDE INDIA Technical discipline: MQ

Dimensions in mm

1 Lifting Lugs

1) The welds shall be arranged in such manner that the entire cross-section of the web is attached to the vessel wall. Weld craters are inadmissible.

Figure 1

Table 1

The load per lug shall be based on force F1 at an angle of β = 0° to180° in direction of lug according to figure 1. The admissible forces are approximate values. The manufacturer shall submit stress analysis documents reflecting the required dimensions and loads for the vessel or item of equipment. Materials: Killed carbon steel. If vessel is of high-alloy steel, the web and reinforcement plate shall be of the same material.

Page 9: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement

UHDE-STANDARD UN

2000-07 Part 1 (M)

Vessels and Equipment

LIFTING LUGS AND LIFTING TRUNNIONS for erection of steel vessels Page 2 of 5

2 Lifting Lugs Type A without reinforcement plate Type B with reinforcement plate

Reinforcement plates are required in the following cases:

a) Vessels with a wall thickness of <6mm b) Vessels of fine grained steels c) Vessels of austenitic steels

d) Vessels susceptible to denting e) Vessels with brittle linings such as ebonite,

enamel, ceramic lining, etc.

Figure 2

Figure 3 Arrangement

Table 3

Page 10: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement

UHDE-STANDARD UN

2000-07 Part 1 (M)

Vessels and Equipment

LIFTING LUGS AND LIFTING TRUNNIONS for erection of steel vessels Page 3 of 5

The admissible forces are approximate values and shall only be transmitted in the direction of lug by means of shackles. The manufacturer shall submit stress analysis documents reflecting the required dimensions and loads for the vessel or item of equipment.

Materials: Killed carbon steel. If vessel is of high-alloy steel, the web and reinforcement plate shall be of the same material.

3 Lifting Trunnions

Figure 4

Page 11: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement

UHDE-STANDARD UN

2000-07 Part 1 (M)

Vessels and Equipment

LIFTING LUGS AND LIFTING TRUNNIONS for erection of steel vessels Page 4 of 5

The admissible forces are approximate values. The manufacturer shall submit stress analysis documents reflecting the required dimensions and loads for the vessel or item of equipment.

Materials: Killed carbon steel. If vessel is of high-alloy steel, the web and reinforcement plate shall be of the same material.

4 Lifting Trunnions, long type

2) l2 may be smaller but the min. length shall be the length of nozzle or clip above the trunnion plus 50mm

Figure 5

Page 12: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement

UHDE-STANDARD UN

2000-07 Part 1 (M)

Vessels and Equipment

LIFTING LUGS AND LIFTING TRUNNIONS for erection of steel vessels Page 5 of 5

Table 5

The admissible forces are approximate values. The manufacturer shall submit stress analysis documents reflecting the required dimensions and loads for the vessel or item of equipment.

Materials: Killed carbon steel. If vessel is of high-alloy steel, the web and reinforcement plate shall be of the same material.

Page 13: Vessels and equipment UN 2004-06 INSULATION CLIPS …pvtools.weebly.com/uploads/3/7/9/4/37946983/part_2.pdf · 4.1 Design Clips shall be ... 2 Lifting Lugs Type A without reinforcement