CopyrightCopyrightCopyrightCopyright CCCC 2005200520052005bybybyby Osstem Implant Co.,LtdOsstem Implant Co.,LtdOsstem Implant Co.,LtdOsstem Implant Co.,Ltd.
This user guide and the V-cephTM program are
protected by Copyright Laws and Program Protection
Regulations.
OSSTEM IMPLANT Co,.Ltd.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
2/151
2222 VVVV----cephcephcephceph
V-ceph Key Features.
IBM-PC Based Operating System
Vceph is compatible with Ms Windows operating systems. Unlike many other existing programs,no other hardware is required to operate Vceph for PC users. Users can operate the software on
a single PC. In addition, this software is compatible with almost all the peripherals and doesn't
need any special devices.. We recommend 1G RAM and an IBM compatible PC with a Intel@
Core 2 Duo CPU or higher and 100GB hard drive or higher .
Easy Transfer of Patient Data
You might have difficulty in transferring patients' data to another PC. But this is not a problem any
more if you use Vceph by using its powerful database function .
User-friendly Interface on Windows Basis
The familiar user-interface of Vceph allows clinicians to use it quite easily.
Image Enhancement
There are some special functions that only Vceph has. An old and/or obscure Ceph film may
have annoyed you. How about using the unique "Image enhancement" function of Vceph?
Certainly you will feel better with Vceph.
Image FusionTM
Experience the Image Processing Technology unique to V-ceph. You can maximize the effect of
patients consultation by showing them the pre and post-operation images gradually.
Exporting the process of image changes to video clip.
You can save as AVI video clip the process of comparing images made by Image Fusion.
Gallery Format
You can view and print and save the patient images using the Gallery Format(Total number of
formats is 23). Image Format, moreover, is very useful for patient consultations.
Simplified Line Drawing
You can input the Upper/Lower Profile precisely by clicking only Soft tissue landmarks. You can
draw all the lines by point click or mouse drag. In addition to that, V-ceph presents Undo/Redo
function for the users convenience.
Exporting Analysis results to Microsoft Excel format
You can save in the form of Microsoft Excel a variety of measurements and mean values.
Simple Image Editing
tng thch vi he ieu hanh Ms Windows. Khong nh nhieu chng trnh ang s dung khac, Vcephkhong yeu cau mot phan cng rieng e s dung. Ngi s dung co the van hanh phan mem nay tren mot maytnh rieng le. Them na, phan mem nay tng thch vi hau het tat ca cac thiet b ngoai vi va khong can bat kymot thiet b ac biet nao. Chung toi khuyen dung may vi tnh Ram 1G va mot may tnh tng thch IBM co n vx ly trung tam Core 2 Duo hoac cao hn va o cng 100GB hoac cao hn.
- He ieu hanh da tren IBM-PC
- De dang chuyen oi thong tin benh nhan
Ban co thegap kho khan trong viec chuyen d lieu benh nhan sang may tnh khac. Nhng khong conla van e khi ban s dung Vceph nh chc nang c s d lieu (database) hu dung cua no.
Giao dien-ngi s dung quen thuoc cua Vceph cho phep nha s s dung phan mem nay rat de dang
Co mot so chc nang ac biet ma ch Vceph mi co. Film chup cu va/hoac m co the gayphien toai cho ban. Con s dung chc nang oc ao "Image enhancement" cua Vceph th nhthe nao? D nhien, ban se cam thay tot hn nhieu khi s dung Vceph.
Xuat quy trnh sa hnh anh qua video clip
Ban co the lu di dang AVI quy trnh so sanh hnh anh c lam bi chc nang ImageFusion
Ban co the xem, in va lu hnh anh benh nhan bang cach s dung chc nang Gallery Format(Tong so kho la 23). Hn na, Image Format la mot chc nang rat hu dung cho nhng lan
tham van benh nhan.
Ban co the them Profile pha tren hay di mot cach chnh xac bang cach click vao moc momem. Ban co the o hoa tat ca cac ng bang cach click tng iem hay keo chuot. Themvao o, Vceph gii thieu chc nang Undo/Redo tao s thuan tien cho ngi s dung.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
- Bien tap hnh anh n gian
-Cai thien hnh anh
Trai nghiem Cong nghe X ly Hnh anh oc ao vi Vceph. Ban co the toi a hoa hieu qua cua viectham van benh nhan bang cach dan dan ch cho ho nhng hnh anh trc va sau phau thuat.
- Viec ve ng vach c n gian hoa
Ban co the lu dang Excel mot loat cac so o va tr so trung bnh
-
8/22/2019 Vceph6.0 Manual Viet Osstem
3/151
3333 VVVV----cephcephcephceph
You can control the position of the scanned image input in slide view by using the rotation, and get
the necessary part of the image by cropping.
Digitizing with Magnifier Cursor
You can magnify some part of X-ray film image by mouse cursor and then, find Landmarks more precisely
and easily.
Easy Morphing
With just a few mouse clicks you can perform powerful Morphing techniques to graphically display
surgery and Growth Forecast. This visual representation is a powerful tool for both patients and
internal use.
Report System
V-ceph report system simplifies and automates generating referral and patient letters. Every letter
can now include patient's pictures and data. You can customize your own report templates about
diagnosis and treatment plan.
Auto Tracing
Basic structures such as maxilla, symphysis, mandible, extra outline are drawn automatically when
you digitize.
Contact Sheet
Set the layout and make several photos into one photo you need. Save the file or use it for your
brief slide show to your patient.
X-Ray Superimposition
Superimpose 2 X-rays of before and after treatment. Immediate comparison of treatment is possible with this
function.
< DISCLAIMER >
Presentation from this program is an only simulation and is not designed to guarantee the actual surgical or
Ban co the kiem soat v tr cua hnh anh scan them vao trong khung hnh bang cach xoay, valay phan can thiet bang chc nang cat xen hnh anh
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Ban co the phong to mot so phan cua hnh chup phim X-quang bang con tro chuot va sau o, tmmoc chnh xac va de dang hn.
Ch vi mot vai cai click chuot, ban co the thc hien cac ky thuat Morphing (bien oi hnh anh)hu hieu e hien th phau thuat mot cach sinh ong va d oan s phat trien. S trnh bay trcquan la mot cong cu hu hieu cho ca benh nhan va bac s s dung.
-He thong bao cao
He thong bao cao V-ceph lam n gian va t ong hoa d lieu phat sinh va th benh nhan.Moi la th co the bao ham hnh anh va thong tin cua benh nhan. Ban co the tuy chnh maubao cao cua rieng mnh ve ke hoach chan oan va ieu tr.
-o hoa t ong
Cau truc c ban nh ham tren, hien tng dnh cau truc, ham di, ng phac hoa them cve t ong khi ban so hoa.
Sheet lien lac
Thiet lap s o bo tr va bien mot vai anh thanh mot anh ban can. Lu thanh file hay s dung no etrnh chieu slide show ngan cho benh nhan xem.
-Bien oi hnh de dang
-So hoa bang con tro phong to
Xep chong 2 hnh anh X-quang trc va sau ieu tr. Viec so sanh ket qua ieu tr tc th la co the vi
chc nang nay.
-Xep chong hnh anh X-quang
han trnh bay t chng trnh nay ch la s mo phong va khong c thiet ke nham am bao nhng ketua chnh nha.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
4/151
4444 VVVV----cephcephcephceph
orthodontic results.
< Analysis>
The allowable margin of error of each of measured values is less than 1. 5 degree or 1mm
V-cephTM is a program for orthodontist, oral and maxillofacial surgeon andplastic surgeon to aid in diagnosis, treatment planning, etc.
This software has been developed with many specialists consultations and this helps in
many clinical situations such as diagnosis, establishing treatment plan, growth forecast,
orthognathic surgery simulation, etc.
[-Enter all the digital film images such as lateral film and frontal film into Vceph software
-Digitize all the required landmarks on the film shown on the monitor
-Automatically Vceph measures the angle, distance, added value and percentage value
of the landmarks digitized.
- It is possible to visualize the soft-tissue change by simulating the original lateral photo.
- By presenting original and predicted photo simultaneously on the screen.]
Vceph helps to plan treatment procedure and consult patients effectively.
VVVV----ceph Key Features.ceph Key Features.ceph Key Features.ceph Key Features. ________________________________________________________________________________________________________________________________________________________________________________________ 2222
1111 InstallationInstallationInstallationInstallation ________________________________________________________________________________________________________________________________________________________________________________________________________________ 12121212
2222 Running ProgramRunning ProgramRunning ProgramRunning Program ________________________________________________________________________________________________________________________________________________________________________________________ 14141414
2.1 Main Screen Layout ___________________________________________________________ 14
2.1.1 Set a working directory path ________________________________________________________ 14
2.1.2 Make Directory ___________________________________________________________________ 15
2.1.3 New_____________________________________________________________________________ 17
With this icon, you can register a new patient. ____________________________________________________ 17
2.1.4 Search___________________________________________________________________________ 17
With this icon, you can search or sort out existing patients with specific conditions or key-words. ___________ 17
Vi bieu tng nay, ban co the ang ky benh nhan mi.
Vi bieu tng nay, ban co the tm kiem nay sap xep nhng benh nhan hien tai vi iem ac biethay t khoa.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Gii han loi cho phep cua moi tr so c o la t hn 1,5 o hoac 1mm.
la chng trnh danh cho bac s chnh nha, bac s phau thuat ham-mat va mieng va bac sphau thuat tao hnh e ho tr viec chan oan, lap ke hoach ieu r, v.v.Phan mem nay a c phat trien vi nhieu tham van t pha cac chuyen gia va phan memnay giup ch trong nhieu tnh huong lam sang nh chan oan, thiet lap ke hoach ieu tr, d
oan s phat trien, mo phong phau thuat ho mom, v.v.(-Nhap tat ca cac hnh anh film ky thuat so nh film mat ben va film mat trc vao phan memVceph- So hoa tat ca cac moc c yeu cau tren film c the hien tren man hnh- Vceph t ong o goc, khoang cach, tr so bo sung va tr so phan tram cua cac moc c sohoa- Co the hien th s thay oi mo mem bang cach mo phong anh mat ben goc.- Bang cach trnh bay anh goc va c d oan trc mot cach ong thi tren man hnh.)Vceph giup lap ke hoach quy trnh ieu tr va tham van benh nhan mot cach hieu qua.
Gii han loi cho phep cua moi tr so c o la t hn 1,5 o hoac 1mm.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
5/151
5555 VVVV----cephcephcephceph
2.1.5 Delete ___________________________________________________________________________ 17
With this icon, you can delete existing patient information and relevant images __________________________ 17
2.1.6 Select ___________________________________________________________________________ 172.1.7 Export __________________________________________________________________________ 17
2.1.8 Import __________________________________________________________________________ 18
2.1.9 View Info ________________________________________________________________________ 18
2.1.10 Print ____________________________________________________________________________ 18
2.1.11 Excel____________________________________________________________________________ 18
2.1.12 List Setting_______________________________________________________________________ 18
2.2 Patient Information Window ____________________________________________________ 19
2.2.1 New (Making new Data-Set) ________________________________________________________ 20
2.2.2 Edit (Data-Set Edit) ______________________________________________________________ 20
2.2.3 Delete ( delete Data-Set) ____________________________________________________________ 21
2.2.4 Hanaro DB Search ________________________________________________________________ 21
2.2.5 Appointment _____________________________________________________________________ 21
2.2.6 SMS ____________________________________________________________________________ 22
2.2.7 Select ( open Data-Set) _____________________________________________________________ 23
2.2.8 Advanced Info ____________________________________________________________________ 23
2.3 Slide Window _________________________________________________________________ 242.3.1 Input Images _____________________________________________________________________ 25
) Scan (Scanning Image by Scanner) _________________________________________________ 26
) Import___________________________________________________________________________ 26
) Import Manager __________________________________________________________________ 26
) Export Manager (Image Export Manager) ____________________________________________ 27
) Delete___________________________________________________________________________ 28
2.3.2 Calibration / Crop / Adjusting Image Angle____________________________________________ 29
) Set Image Size (Calibration)________________________________________________________ 29
) Image Size Definition______________________________________________________________ 30
) Crop ____________________________________________________________________________ 31
) Rotate Image ____________________________________________________________________ 32
) Window Width & Level_____________________________________________________________ 32
2.3.3 Rotation / Flip ____________________________________________________________________ 33
) 90 CW Rotation__________________________________________________________________ 33
) 90 CCW Rotation ________________________________________________________________ 33
) Arbitrary Rotation _________________________________________________________________ 33
) Horizontal Flip____________________________________________________________________ 34
Vi bieu tng nay, ban co the xoa thong tin benh nhan hien tai va hnh anh lien quan
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
6/151
6666 VVVV----cephcephcephceph
) Vertical Flip ______________________________________________________________________ 34
2.3.4 Change Image Modality ____________________________________________________________ 34
2.3.5 Image Contact Sheet_______________________________________________________________ 352.3.6 Image OverLay ___________________________________________________________________ 36
2.3.7 Image location (Data-Set Rearrangement) _____________________________________________ 36
2.3.8 Image Process ____________________________________________________________________ 37
2.3.9 Additional Menu in Main Menu _____________________________________________________ 38
) Measure_________________________________________________________________________ 38
) Analysis _________________________________________________________________________ 39
) Preference_______________________________________________________________________ 39
) Briefing__________________________________________________________________________ 48
2.4 Print ________________________________________________________________________ 49
3333 Main FunctionsMain FunctionsMain FunctionsMain Functions ________________________________________________________________________________________________________________________________________________________________________________________________ 51515151
3.1.1 Toolbar & Icon reference Icon _______________________________________________ 51
) Digitize __________________________________________________________________________ 51
) Correction _______________________________________________________________________ 52
) Align to Photo ____________________________________________________________________ 52
) Click Zoom ______________________________________________________________________ 52
) Rect Zoom_______________________________________________________________________ 52
) Actual Size ______________________________________________________________________ 52
) Pan _____________________________________________________________________________ 52
) Image Enhancement ______________________________________________________________ 52
) Axis Change _____________________________________________________________________ 52
) Toggle Tracing ___________________________________________________________________ 52
) Frontal Film ______________________________________________________________________ 52
) Frontal Photo ____________________________________________________________________ 52
) Lateral Film ______________________________________________________________________ 53
) Lateral Photo_____________________________________________________________________ 53
) Panorama _______________________________________________________________________ 53
16) Model Photo _____________________________________________________________________ 53
17) IntraOral Photo ___________________________________________________________________ 53
3.1.2 Toolbar__________________________________________________________________________ 53
) VTO / STO_______________________________________________________________________ 53
) Growth Forecast__________________________________________________________________ 53
-
8/22/2019 Vceph6.0 Manual Viet Osstem
7/151
7777 VVVV----cephcephcephceph
) Superimposition __________________________________________________________________ 53
) Gallery __________________________________________________________________________ 53
) Chart ___________________________________________________________________________ 53
) Image Fusion ____________________________________________________________________ 53
3.2 How to Digitize ________________________________________________________________ 54
3.2.1 Select a mode _____________________________________________________________________ 54
3.2.2 Determine Landmarks on Lateral View _______________________________________________ 56
3.2.3 Lateral Trace Guide Window________________________________________________________ 58
3.2.4 Digitize Window Digitizing Toolbar reference_________________________________________ 58
) Back ____________________________________________________________________________ 59
) Cancel __________________________________________________________________________ 59
) Restart __________________________________________________________________________ 59
) Save & Finish ____________________________________________________________________ 59
) Image Enhancement One-click Image Enhancement_________________________________ 59
3.2.5 Drawing Upper & Lower Profiles by Digitizing Points ___________________________________ 59
3.2.6 Auto Tracing _____________________________________________________________________ 60
3.2.7 Drawing Extra Line _______________________________________________________________ 61
3.3 How to Correct _______________________________________________________________ 63
3.3.1 Correction Helper Window _________________________________________________________ 63
) Undo____________________________________________________________________________ 63
) Redo____________________________________________________________________________ 63
) Add _____________________________________________________________________________ 63
) Erase ___________________________________________________________________________ 63
) Erase & Redraw __________________________________________________________________ 64
) Image Enhancement ______________________________________________________________ 64
3.3.2 Correct the landmark point / Select Profile to be Corrected ______________________________ 64
3.3.3 Correcting Profile : moving correction points or whole profile ____________________________ 65
3.3.4 Insert & Delete correction points_____________________________________________________ 66
3.3.5 Matters that require attention, When Correct Upper / Lower Profile_______________________ 67
3.3.6 Arrange measurement position ______________________________________________________ 67
3.3.7 Save ____________________________________________________________________________ 68
3.4 Align Cephalogram(tracing) to Photo _____________________________________________ 68
3.4.1 Select a mode _____________________________________________________________________ 68
3.4.2 Align to photo ____________________________________________________________________ 69
) Movement _______________________________________________________________________ 69
-
8/22/2019 Vceph6.0 Manual Viet Osstem
8/151
8888 VVVV----cephcephcephceph
) Resizing & Rotation _______________________________________________________________ 69
3.4.3 Save ____________________________________________________________________________ 70
3.4.4 Correct Profile on Photo____________________________________________________________ 71
3.5 How to Analyze _______________________________________________________________ 72
3.5.1 Select Analysis Method_____________________________________________________________ 73
3.5.2 Polygonal Chart __________________________________________________________________ 73
3.6 VTO / STO ___________________________________________________________________ 74
3.6.1 Treatment Control Window _________________________________________________________ 76
) Apply ___________________________________________________________________________ 77
) Undo____________________________________________________________________________ 77
) Redo____________________________________________________________________________ 77
) Reset ___________________________________________________________________________ 77
) Morph___________________________________________________________________________ 77
) Compare Photos _________________________________________________________________ 77
) Compare Lines ___________________________________________________________________ 80
) Auto Rotate ______________________________________________________________________ 80
3.6.2 Profile Correction during treatment simulation ________________________________________ 80
3.6.3 Simulation Handler________________________________________________________________ 81
3.6.4 Save Treatment Simulation Result ___________________________________________________ 82
3.7 Growth Forecast ______________________________________________________________ 83
3.7.1 Save Growth Forecast Result________________________________________________________ 84
3.8 Superimposition _______________________________________________________________ 84
3.8.1 Select Data _______________________________________________________________________ 84
3.8.2 Select Superimposition _____________________________________________________________ 85
3.8.3 Superimposition fine adjustment_____________________________________________________ 87
3.8.4 X-Ray Superimposition ____________________________________________________________ 87
3.8.5 Superimposition Setting ____________________________________________________________ 90
3.9 Gallery ______________________________________________________________________ 93
3.9.1 Select Gallery Format______________________________________________________________ 93
3.9.2 Back to previous Window / Print / Save as image file / Capture____________________________ 94
3.10 Image Fusion _________________________________________________________________ 95
3.10.1 Photo Film Fusion _______________________________________________________________ 95
) Mode 1__________________________________________________________________________ 95
) Mode 2__________________________________________________________________________ 96
-
8/22/2019 Vceph6.0 Manual Viet Osstem
9/151
9999 VVVV----cephcephcephceph
) Mode 3__________________________________________________________________________ 96
3.10.2 Original Morph Photo Fusion______________________________________________________ 97
4444 PA AnalysisPA AnalysisPA AnalysisPA Analysis ____________________________________________________________________________________________________________________________________________________________________________________________________________ 98989898
4.1 How to Digitize ________________________________________________________________ 98
4.1.1 Select a mode _____________________________________________________________________ 98
4.1.2 Determine Landmarks on Frontal View ______________________________________________ 100
4.1.3 Frontal Trace Guide Window ______________________________________________________ 101
4.1.4 Digitize Window Toolbar reference ________________________________________________ 101
) Back ___________________________________________________________________________ 102
) Cancel _________________________________________________________________________ 102
) Restart _________________________________________________________________________ 102
) Save & Finish ___________________________________________________________________ 102
) Image Enhancement One-click Image Enhancement________________________________ 102
4.2 Continue Digitizing ___________________________________________________________ 102
4.3 View Tracing Result __________________________________________________________ 104
5555 Model AnalysisModel AnalysisModel AnalysisModel Analysis ____________________________________________________________________________________________________________________________________________________________________________________________ 105105105105
5.1 Set Image Size (Calibration) ____________________________________________________ 105
5.2 How to Digitize _______________________________________________________________ 105
5.2.1 Upper / Lower Trace Guide Window ________________________________________________ 106
5.2.2 Digitize Window Toolbar reference ________________________________________________ 107
) Back ___________________________________________________________________________ 107
) Cancel _________________________________________________________________________ 107
) Restart _________________________________________________________________________ 107
) Finish __________________________________________________________________________ 107
5.3 Continue Digitizing ___________________________________________________________ 107
5.4 View Tracing Result __________________________________________________________ 109
6666 SMV AnalysisSMV AnalysisSMV AnalysisSMV Analysis ____________________________________________________________________________________________________________________________________________________________________________________________________ 110110110110
6.1 How to Digitize _______________________________________________________________ 110
6.1.1 Select a mode ____________________________________________________________________ 110
6.1.2 SMV Trace Guide Window ________________________________________________________ 111
-
8/22/2019 Vceph6.0 Manual Viet Osstem
10/151
10101010 VVVV----cephcephcephceph
6.1.3 Digitize Window Toolbar reference ________________________________________________ 112
) Back ___________________________________________________________________________ 112
) Cancel _________________________________________________________________________ 112
) Restart _________________________________________________________________________ 112
) Finish __________________________________________________________________________ 112
) Image Enhancement One-click Image Enhancement________________________________ 112
6.2 Continue Digitizing ___________________________________________________________ 112
6.3 View Tracing Result __________________________________________________________ 114
7777 Customized AnalysisCustomized AnalysisCustomized AnalysisCustomized Analysis ________________________________________________________________________________________________________________________________________________________________________ 115115115115
7.1 Landmark and line ___________________________________________________________ 115
7.1.1 New____________________________________________________________________________ 116
7.1.2 Edit____________________________________________________________________________ 117
7.1.3 Delete __________________________________________________________________________ 117
7.1.4 Change the order to input _________________________________________________________ 118
7.2 Calculated Landmark_____________________________________________________________ 118
7.2.1 New____________________________________________________________________________ 119
) Set Type________________________________________________________________________ 120
) Set Parameter according to Type __________________________________________________ 125
7.2.2 Edit____________________________________________________________________________ 125
7.2.3 Delete __________________________________________________________________________ 125
7.3 Analysis _____________________________________________________________________ 126
7.3.1 New____________________________________________________________________________ 127
7.3.2 Edit____________________________________________________________________________ 127
7.3.3 Delete __________________________________________________________________________ 127
7.3.4 Measure ________________________________________________________________________ 128
) New ___________________________________________________________________________ 128
) Delete__________________________________________________________________________ 129
) Analysis Item Setting _____________________________________________________________ 129
) Insert Existing Measure___________________________________________________________ 135
) Data Setting ____________________________________________________________________ 135
) Location On Cephalogram ________________________________________________________ 136
7.3.5 Plane___________________________________________________________________________ 137
) New Plane______________________________________________________________________ 138
) Edit Plane ______________________________________________________________________ 138
-
8/22/2019 Vceph6.0 Manual Viet Osstem
11/151
11111111 VVVV----cephcephcephceph
) Delete Plane ____________________________________________________________________ 138
7.4 Reset _______________________________________________________________________ 139
7.5 Close _______________________________________________________________________ 139
8888 VVVV----ReportReportReportReport ________________________________________________________________________________________________________________________________________________________________________________________________________________ 139139139139
8.1 Main Screen Layout __________________________________________________________ 139
8.2 Main Functions ______________________________________________________________ 140
8.2.1 New Document __________________________________________________________________ 140
8.2.2 DB Read________________________________________________________________________ 140
8.2.3 Report file open / save ____________________________________________________________ 141
8.2.4 Template file open / save___________________________________________________________ 141
8.2.5 Printing ________________________________________________________________________ 141
8.2.6 Text input_______________________________________________________________________ 141
) Text input _______________________________________________________________________ 141
) Input Patient Info ________________________________________________________________ 143
8.2.7 Image Input _____________________________________________________________________ 144
) DB linked image input ____________________________________________________________ 145
8.2.8 Zoom In / Out ___________________________________________________________________ 146
8.2.9 Grid ___________________________________________________________________________ 146
8.2.10 Page ___________________________________________________________________________ 146
) Add page _______________________________________________________________________ 146
) Delete page_____________________________________________________________________ 146
) Delete a Contents of Current page _________________________________________________ 146
) Movement from page to page _____________________________________________________ 146
8.2.11 Select multiple DB________________________________________________________________ 147
8.2.12 Slide-show Presentation with full screen. _____________________________________________ 150
Hellman Dental AgeHellman Dental AgeHellman Dental AgeHellman Dental Age ________________________________________________________________________________________________________________________________________________________________________________________ 151151151151
-
8/22/2019 Vceph6.0 Manual Viet Osstem
12/151
12121212 VVVV----cephcephcephceph
1 Installation
In order to install V-ceph, Insert V-ceph CD in your CD/DVD-ROM on your PC and run Setup.exe
file. And then enter user name and company name that you already informed us. Then click Next
as below. And the installation will start.
When the installation is finished, V-ceph icon will be automatically generated. Double-click it to run
the V-ceph.
Cai at
e cai at Vceph, bo a V-ceph CD vao trong o CD/ DVD ROM tren may tnh ,chay file setup.exe
Va sau o ien ten ngi s dung (user) va ten cong ty a khai bao cho chung toi. Sau o, an "Next"nh di ay. Va chng trnh bat au c cai at.
Khi cai at xong, bieu tng V-ceph se t ong hien len. Nhap Double-click e chaychng trnh
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
13/151
13131313 VVVV----cephcephcephceph
Install Test
No. Test Item Test Method Test Standard Test Result
1 Open V-Ceph
Open V-Ceph on desktop orchoose from All Programs
in start menu.
V-Ceph in proper versionshould be started without
error occuring in any sort.
Pass/Fail
2 Check
registered
key
Check the identity of
hospital/clinic name on the
top of the main screen.
If identified as the same
name as key registry book,
it is regarded as the properly
registered key.
Pass/Fail
3 Open V-
Report
Open V-Report on desktop
or choose from All
Programs in start menu.
V-Report should be started
without error occuring in any
sort.
Pass/Fail
4 Open V-
Analysis
Open V-Analysis on desktop
or choose from All
Programs in start menu.
V-Analysis should be started
without error occuring in any
sort.
Pass/Fail
5 Share
Data
Folder
Click Set Directory option
from the client computer and
search for the data folder in
server computer.
All the patients list in server
computers data folder
should be seen on the client
computer
Pass/Fail
6 Open V-
Ceph from
Net-key
Open V-Ceph from several
networked computers and
check the number of
simultaneous users.
The number of simultanous
users should be according
to the purchased licenses.
If opening V-Ceph fails on
the computer over the limit,
it is regarded as the proper
installation of network
version.
Pass/Fail
M V-Ceph
K iem tra cai at
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Nhap vao bieu tng V-Cephtren desktop hoac chon t "AllPrograms" trong start menu.
Kiem trakeyang ky
Kiem tra danh tnh cua nhakhoa/ benh vien phan trencung cua man hnh chnh
M V-
Report
M V-Report tren desktophay chon t "All Programs"tren start menu.
M V-Analysis
M V-Analysis tren desktophay chon t "All Programs"tren start menu.
Chia seth mucd lieu
Click tuy chon "SetDirectory" tmay khach va tm thmuc d lieu tren may
M V-Ceph t mot vaimay tnh ket noi va kiemtra so ngi s dungong thi
oi tng Phng phap Tieu chuan Ket qua
V-Ceph phien ban unganse bat au ma khong co batky loai loi g xay ra
Neu c nhan dien la cungten nh key a ang ky, thno c xem la key a cang ky mot cach ung an
V-Report can phai c khiong ma khong co bat ky loinao xay ra
V-Analysis can phai ckhi ong ma khong co batky loi nao xay ra
M V-ceph tNet-key
Tat ca cac benh nhan trongdanh sach trong th muc dlieu may chu can phai cnhn thay tren may khach.
Con so ngi s dung ongthi can phai theo cac giayphep a mua. Neu viec mV-ceph that bai tren may tnhvt gii han nay, th noc xem la s cai at ungan phien ban mang
c/Khongc
c/Khongc
c/Khong
c
c/Khongc
c/Khongc
c/Khongc
-
8/22/2019 Vceph6.0 Manual Viet Osstem
14/151
14141414 VVVV----cephcephcephceph
2 Running Program
2.1 Main Screen Layout
When you start V-ceph, the main screen layout is as below, where the registered patient list is displayed. In
this window, you have to set a working directory path, and you can register new patients, or search / sortexisting patient data. Also, it is possible to exchange the information about patient between Users.
2.1.1 Set a working directory path
Set up the directory to save patient information.
To set up directory, choose Set Directory in the menu bar
Chay chng trnhBo cuc man hnh chnh
Khi khi ong V-ceph, man hnh chnh giong ben di, mot list benh nhan a ang ky se hien ra. Trongca so nay, ban phai cai at ng dan th muc lam viec, va ban co the ang ky benh nhan mi, hoactm kiem thong tin benh nhan. ong thi, co the trao oi thong tin benh nhan gia cac ngi s dungvi nhau
Cai at ng dan th muc lam viec
Thiet lap ng dan danh muc e lu thong tin benh nhan
e cai at ng dan, chon 'Set Directory' tren thanh cong cu
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
15/151
15151515 VVVV----cephcephcephceph
When the Dialog Box appears, select a working directory path folder where you can save the patient data. In
this folder, mdb files (Patientinfo / Tabinfo) must be included. It is indispensable to run V-ceph.
2.1.2 Make Directory
In case there is no directory to save patient data, make a new directory.
To make a new directory, choose Make Directory in the menu bar.
Khi hop thoai xuat hien, chon folder ng dan th muc lam viec ni ma ban se lu d lieu benh nhan.Trong th muc nay, file mdb (Patientinfo/ Tabinfo) phai co. No la file khong the thieu c e khi ong V-ceph
Tao th muc
Trong trng hp khong co th muc e lu thong tin benh nhan, tao mot th muc mi.
e tao mot th muc mi, chon 'Make Directory' tren thanh cong cu.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
16/151
16161616 VVVV----cephcephcephceph
When the Dialog Box appears as below, create a new directory.
New directory will be automatically set as default working directory.
.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Khi hop oi thoai xuat hien nh ben di, tao mot th muc mi.
Th muc mi se t ong tr thanh th muc lam viec mac nh.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
17/151
17171717 VVVV----cephcephcephceph
2.1.3 New
With this icon, you can register a new patient.
2.1.4 Search
With this icon, you can search or sort out existing patients with specific conditions or key-
words.
2.1.5 Delete
With this icon, you can delete existing patient information and relevant images
2.1.6 Select
With this icon, you can execute the patient data that you select.
2.1.7 Export
With this icon, you can save the patient data that you select to a file. This file could be exchange
via Internet or E-mail between users.
Mi
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Vi bieu tng nay, ban co the ang ky benh nhan mi.
Tm kiemVi bieu tng nay, ban co the tm kiem hay sap xep benh nhan vi ieu kien ac biethay t khoa
Xoa
Vi bieu tng nay, ban co the xoa thong tin benh nhan hien co va hnhanh lien quan.
Chon la
Vi bieu tng nay, ban co the the hien d lieu benh nhan maban la chon.
Trch Xuat
Vi bieu tng nay, ban co the lu d lieu benh nhan ma ban chon thanh dang file. File nayco the c trao oi thong qua Internet hoac E-mail gia nhng ngi s dung
-
8/22/2019 Vceph6.0 Manual Viet Osstem
18/151
18181818 VVVV----cephcephcephceph
2.1.8 Import
With this icon, you can add the patient data that you received to own list.
2.1.9 View Info
With this icon, you can identify the patient data that you received.
2.1.10 Print
With this icon, you can print a current patient list.
2.1.11 Excel
With this icon, you can convert a current patient list to MS-Excel file.
2.1.12 List Setting
With this icon, you can configure the item list of your patient information as you like.
(Chart Number, Name, Etc).
Nhap
Vi bieu tng nay, ban co the them d lieu benh nhan ma bannhan c vao list rieng
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Xem thong tin
Vi bieu tng nay, ban co the nhan dien d lieu benh nhan ma bannhan
In
Vi bieu tng nay, ban co the in danh sach benh nhanhien tai
Vi bieu tng nay, ban co the chuyen oi danh sach benh nhanhien tai sang file Excel.
Thiet lap danh sachVi bieu tng nay, ban co the nh dang cac muc danh sach benh nhan nh ban muon.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
19/151
19191919 VVVV----cephcephcephceph
2.2 Patient Information Window
In Patient Information Window, you can input and manage basic information about patients.
(ATTENTION : You must input Patient No, Name, Birth, Gender, Hellman Dental Age, Classification)
And you can manage the details related to diagnosis in Advanced info
You can make new patient records and can classify them into many levels according to the times or
treatment levels. And you can manage photos and diagnosis data separately in terms of the pre / mid/ post-
treatment.
Ca so thong tin benh nhan
Trong ca so thong tin benh nhan, ban co the nhap va quan ly cac thong tin c ban ve benh nhan.
CHU Y: Phai ien ay u
Va ban co the quan ly cac chi tiet lien quan en chan oan trong Advanced info
Ban co the tao ho s benh nhan mi va phan loai theo nhieu cap o da theo thi gian hay mc o ieutr. Va ban co the quan ly hnh anh va d lieu chan oan mot cach rieng biet ve thong tin trc/ trong/saugiai oan ieu tr.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
20/151
20202020 VVVV----cephcephcephceph
2.2.1 New (Making new Data-Set)
With this icon, you can register a new Data-Set as below.
2.2.2 Edit (Data-Set Edit)
With this icon, you can alter the Date or Description
W h e n m a k i n g a r e c o r d , c o n s e c u t i v e
n u m b e r s i s g e n e r a t e d a u t o m a t i c a l l y f r o m
0 0 0 t o 9 9 9 .
Mi (Tao Data-set mi)
Vi bieu tng nay, ban co the ang ky mot Data-set mi nh ben di
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Chnh sa (Chnh sa Data-set)
Vi bieu tng nay, ban co the thay oi ngay thang hoac phan mo ta.
Khi tao mot ho s, so em senhay t ong t 000 en 999.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
21/151
21212121 VVVV----cephcephcephceph
2.2.3 Delete ( delete Data-Set)
With this icon, you can delete corresponding images as well as patient data
2.2.4 Hanaro DB SearchIf you use Hanaro Practice Management Software, integration with Vceph is possible. You can import the
patient data you need from Hanaro software.
Click Search button and all the patient lists of Hanaro appear. Select the patient you need to import and
click OK.
2.2.5 Appointment
If you are a Hanaro software user, make a next appointment with your patient with this function. Click
Xoa (xoa Data-set)Vi bieu tng nay, ban co the xoa thong tin hnh anh cung nh d lieu benh nhan.
Tm kiem Hanaro DBNeu ban s dung phan mem quan ly thc hanh Hanaro, co the tng thch vi V-ceph. Ban co thenhap d lieu benh nhan ban can t phan mem Hanaro.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
An 'Search' va tat ca list benh nhan Hanaro xuat hien. Chon benh nhan ban can va an'OK'.
Neu ban la mot ngi s dung phan mem Hanaro, at cuoc hen ke tiep vi benh nhan bang chc nangnay. An 'Appointment'
Hen
-
8/22/2019 Vceph6.0 Manual Viet Osstem
22/151
22222222 VVVV----cephcephcephceph
Appointment.
2.2.6 SMS
If you are a Hanaro software user, you can improve customer satisfaction and appointment-observance rate
by sending SMS.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Neu ban la ngi s dung phan mem Hanaro, ban co the cai thien mc o hai long cuakhach hang va ty le am bao cuoc hen bang cach gi SMS.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
23/151
23232323 VVVV----cephcephcephceph
2.2.7 Select ( open Data-Set)
With the icon, you can see the corresponding Data-Set.
2.2.8 Advanced Info
Record the advanced information of your patient in detail. Make it sure to click Update button whenever
there is a modification.
La chon (m Data-Set)
Vi bieu tng nay, ban co the thay Data-Set tng ng
Thong tin chuyen sau
Ghi lai mot cach chi tiet ve thong tin chuyen sau cua benh nhan. Hay am bao chac chan la an nut
'Update' bat c khi nao co s thay oi.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
24/151
24242424 VVVV----cephcephcephceph
2.3 Slide Window
When you input images, they are automatically renamed in data folder.You have to input image in the designated location to use Gallery function provided by V-ceph. When you
need to input special reference images besides the designated, you can add maximum 100 extra Images.
Doubleclick the record you need to import images
Ca so trt (slide)
Khi ban nhap hnh anh vao, chung se t ong oi ten trong th muc d lieu.Ban phai at hnh anh vao v tr a c ch nh e s dung chc nang 'Gallery function' do Vceph mang lai. Khiban can at hnh anh tham chieu ac biet ngoai v tr ch nh, ban co the them toi a la 100 hnh anh.
vao ho s ban can e nhap hnh anh
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
25/151
25252525 VVVV----cephcephcephceph
Changing the name of slide : Double-click the name of extra slide and rename it.
2.3.1 Input Images
Clicking the right button on the location for image input, Pop-Up menu will appear as below. With these pop-
up menus, you can input or edit image. And you can also edit by using Edit in main menu. 1024 X 768
pixel image size is recommended for V-ceph.Although there is no limit to image size, there can be need
for higher PC specifications or slower operating speed for bigger image size. For the smooth operation of
Vceph, we recommend that you reduce an image size before import to Vceph.
Thay oi ten slide: Double-click vao ten cua slide phu them va oi ten no.
Nhap hnh anh vao
Nhap chuot phai vao v tr hnh anh, xuat hien mot menu nh ben di. Vi menu so nay, ban co the nhaphay chnh sa hnh anh. Va ban co the chnh sa bang cach s dung chc nang 'Edit' tren menu chnh.Hnh anh 1024 x 768 pixel c khuyen dung cho Vceph. Mac du khong co gii han ve kch thc hnhanh, nhng can nhng PC manh va toc o phan tch cham cho nhng hnh anh co kch thc ln hn. echo viec phan tch bang Vceph nhe nhang, chung toi khuyen ban nen giam bt kch thc trc khi nhapvao Vceph.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
26/151
26262626 VVVV----cephcephcephceph
) Scan (Scanning Image by Scanner)
Scan and input images with imaging device installed in Windows. Use the Film scanner or Digital cameradirectly connected to your PC. You can use any device compatible to Windows(OS).
With digital camera, 1024 by 768 pixel image size is recommended.
When you input film image with scanner, select UTA Transport orPositive film and input 100~150dpi &
100% scale. If you input 35mm slide film, 400 dpi or higher is recommended.
) Import
Import each image(such as JPG, BMP, TIF, DICOM) saved in hard disk, or Memory Card Reader of Digital
Camera. When you would like to import several images at a time, use Import Manager.
) Import Manager
You can input several images at a time simply by Drag & Drop at designated location. When you finish
image input, just click to complete.
Scan (Scan hnh anh bang may Scan)
Scan va nhap hnh anh bang thiet b tao hnh anh c cai at trong Windows. S dung Film scaner hay camera kythuat so ket noi trc tiep vi may tnh. Ban co the s dung bat ky thiet b nao tng thch vi he ieu hanh Windows.
Vi camera ky thuat so, hnh anh kch thc 1024x768 c khuyen dung.
Khi nhap hnh anh bang may scan, chon UTA Transport hay Positive film va nhap 100~150dpi & tyle 100%. Neu ban nhap slide 35mm, th mc 400dpi hay cao hn c khuyen dung
Nhap hnh anh
Nhap moi hnh anh (nh JPG, BMP, TIF, DICOM) a c lu vao trong o cng, hay bo oc the nh cuacamera ky thuat so. Khi ban muon nhap nhieu hnh anh cung mot thi iem, s dung chc nang quan lynhap
Quan ly nhapBan co the nhap nhieu hnh anh cung mot thi iem bang cach keo va tha vao v tr la chon.
Khi nhap hnh anh xong, an e hoan tat.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
27/151
27272727 VVVV----cephcephcephceph
) Export Manager (Image Export Manager)
With export manager, you can send images by e-mail and save them in a file form.
Quan ly trch xuat (Quan ly trch xuat hnh
Vi phan quan ly trch xuat, ban co the gi hnh anh bang e-mail va lu chung dang file.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
28/151
28282828 VVVV----cephcephcephceph
) Delete
Delete the input image in Data-Set.
If you click Yes, the image is deleted.
XoaXoa hnh anh a nhap trong Data-Set
Neu chon 'Yes', th hnh anh se b xoa
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
29/151
29292929 VVVV----cephcephcephceph
2.3.2 Calibration / Crop / Adjusting Image Angle
) Set Image Size (Calibration)
There is no length information in image taken by Digital Camera. In this case, you can input lengthinformation by clicking two points on the image taken by Digital Camera as below. To reduce error, draw
the line diagonally. (For example, From Top-right corner to Down-left cornet)
To set the whole image size, Input real length to Marked logical lengthfield.
nh kch thc hnh anh (Calibration)
Khong co thong tin chieu dai hnh anh c chup bi camera ky thuat so. Trong trng hp nay, banco the at thong tin chieu dai bang cach click 2 iem tren hnh anh nh ben di. e giam bt loi, vemot ng cheo. (V du: T goc tren ben phai en goc di ben trai)
e thiet lap kch thc toan hnh, nhap chieu dai that vao o 'Marked logical length'
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
30/151
30303030 VVVV----cephcephcephceph
) Image Size Definition
In a situation you get the film with wrong length from a particular X-ray machine, click Set Default Size to
set it as a default enlargement rate. It means you will get the same size of film from the same machine everytime once you carry out manual calibration only one time.(eg. 100% 110%)
After the setting completed, go to Default Setting(MenuPreferenceDefault Setting) and check the box.
M a k e u s e o f m a g n i f i e r f o r
m o r e p r e c i o u s c a l i b r a t i o n
nh ngha kch thc hnh anh
Trong trng hp ban co mot tam hnh vi kch thc sai t may X-Quang cu the, click "Set Default Size"
e thiet lap no ve dang ty le phong mac nh. ieu o co ngha la ban co nhng hnh anh co cung kchthc t cung mot may moi khi ban thc hien hieu chnh bang tay ch 1 lan. (VD 100% -> 110%)
Sau khi thiet lap hoan tat, vao va kiem tra hop
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
31/151
31313131 VVVV----cephcephcephceph
) Crop
Crop the image as you wish.
nhan hnh anh nh ban mong muon
Nhan hnh anh
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
32/151
32323232 VVVV----cephcephcephceph
) Rotate Image
Modify image angle simply by dragging your mouse when the photo taken is oblique as below.
) Window Width & Level
Change Brightness & Contrast of image.
Xoay hnh anh
Thay oi goc hnh anh mot cach n gian bang keo re chuot khi anh chup b chech nh hnh ben di
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Mc & Chieu rong ca so
Chnh o sang va o tng phan hnh anh
-
8/22/2019 Vceph6.0 Manual Viet Osstem
33/151
33333333 VVVV----cephcephcephceph
2.3.3 Rotation / Flip
It sometimes happens that the input image is reversed up to down or left to right. In this case, you can modify
it directly in Data-Set without rescanning again.
) 90 CW Rotation
Rotate the image at 90 clockwise
) 90 CCW Rotation
Rotate the image at 90 counter-clockwise.
) Arbitrary Rotation
Rotate the image in detail by inputting the number of angle.
Xoay hnh/ ao hnh
oi khi hnh anh at vao b ao ngc tren xuong di hay trai thanh phai. Trong trng hp nay, ban cansa oi no trc tiep trong Data-set ma khong can scan lai.
Xoay hnh anh mot goc theo chieu kim ong ho
Xoay hnh anh mot goc ngc chieu kim ong ho
Xoay hnh anh theo y bang cach nhap goc can xoay
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
34/151
34343434 VVVV----cephcephcephceph
) Horizontal Flip
Reverse the image horizontally.
) Vertical FlipReverse the image vertically.
2.3.4 Change Image Modality
Swap image location as you wish just by Drag & Drop in Data-Set.
ao ngc hnh anh theo chieu ngang
ao ngc hnh anh theo chieu doc
Thay oi v tr hnh anh nh mong muon ch bang cach keo va tha trong Data-Set
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
35/151
35353535 VVVV----cephcephcephceph
2.3.5 Image Contact Sheet
Contact Sheet produces a series of thumbnail previews on a single sheet from the files in the selected record.
By displaying a series of thumbnail previews on a single page, Contact Sheets let you easily preview andcatalog groups of images. You can easily place thumbnails on a page by dragging image. You can select any
image size and layout as you want.
Contact Sheet tao mot loat hnh anh xem trc dang nho tren mot trang t cac file trong ho s c chon.
Bang cach the hien mot loat hnh anh nho tren mot trang, Contact Sheet giup ban de dang xem trc va lammuc luc cac nhom hnh anh. Ban co the de dang at cac hnh nay len mot trang bang cach keo hnh. Ban cothe chon la bat ly kch thc va dang bo tr ma ban muon.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
36/151
36363636 VVVV----cephcephcephceph
2.3.6 Image OverLay
Image OverLay produces a thumbnail previews on a single sheet from any different two images. For
example, By clicking Move/Rotate/Zoom button, you can adjust images size.
2.3.7 Image location (Data-Set Rearrangement)
Swap image location as you wish just by drag&drop in Data-Set.
Image OverLay tao ra mot hnh anh xem trc tren mot trang t 2 hnh anh khac nhau bat ky. V du, bang
cach click nut Move/Rotate/Zoom, ban co the ieu chnh kch thc hnh anh
Thay oi v tr hnh anh ma ban muon bang cach keo va tha trong Data-Set
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
37/151
37373737 VVVV----cephcephcephceph
2.3.8 Image Process
) As shown in the picture below, right-click the image you want to revise and select Image Process.
The following window appears:
Nh hnh ben di, nhap chuot phai vao hnh can chnh sa va chon cach Image Process
X ly hnh anh
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
u n c a ssau:
-
8/22/2019 Vceph6.0 Manual Viet Osstem
38/151
38383838 VVVV----cephcephcephceph
(Morph button): This button lets you revise any part of the image randomly (nose, jaw, lips, forehead, etc.).
When the window opens, proceed in sequence.
(Clone Button): Right-clicking allows the duplication of the target color (color of the circle), whereas left-
clicking lets you indicate the cloned color so that you can revise the image.
(Blur Button): It enables blurring and smoothing the revised parts in
.
(Zoom Button): It allows the magnification and shrinkage of the image prior to starting work.
(# Revision occurs when overwriting during saving. Saving under another name is enabled)
2.3.9 Additional Menu in Main Menu
When Data-Set window is opened, Analysis and Preference menus are added to file menu.
) Measure
You can simply measure length, angle, and area without tracing.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Menu phu them trong Menu chnh
(Morph Button): Not nay cho phep ban chnh sa bo phan bat ky cua hnh anh mot cach ngau nhien (mui,ham, moi, tran, v.v.). Khi ca so nay m ra, th tien hanh theo trnh t.
Cho phep lam m va nhan phan c chnh sa
(Clone Button): Viec click chuot phai cho phep nhan mau ch len (mau cua vong tron), trong khi click chuottrai cho phep ban the hien mau c nhan len sao cho ban co the chnh sa hnh anh.
Cho phep phong ai va thu nho hnh anh trc khi bat au cong viec.
(So lan chnh sa xuat hien khi ghi chong trong suot qua trnh lu. Cho phep lu di ten khac)
Khi ca so Data-Set c m, menu phan tch va menu tham chieu c bo sung vao menu file.
Ban co the o o dai, goc va die tch mot cach n gian ma khong can phai ke
-
8/22/2019 Vceph6.0 Manual Viet Osstem
39/151
39393939 VVVV----cephcephcephceph
) Analysis
Analysis menu is not activated in this stage. It becomes activated when you open an image record.
V-ceph provides Ricketts / Steiner / McNamara / Downs / Jarabak / Kims / Burstone as Lateral analysiss
default method. And it also provides PA / SMV / Model Analysis.
) Preference
Preference is menu for preferences about V-ceph.
V-ceph cung cap nh la phng phap
phan tch ben mac nh. Va no cung cung cap phep phan tch PA/ SMV/ Model
-Tham chieu
Phan tham chieu la menu dung cho cac lan tham chieu ve V-ceph
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Menu phan tch cha c khi ong giai oan nay. No se c khi ong khi ban m ho s hnh anh.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
40/151
40404040 VVVV----cephcephcephceph
A. Default Setting
Image Format
Determine the image format used in program. Now, V-ceph 5.5 supports BMP / JPEG image formats.
Jpeg Quality
Determine the image compression ratio used in program.
Log File / Detail Level
In case of problems occurred during using Vceph, use this option to figure out the cause of problem.
Image Size
As Digital X-ray machine has been prevalent these days, Enlargement rate problem of films between
previous and recent has become an issue. With manual calibration performed one time, you set the
enlargement rate as a default. After the calibration, click Set Default Size and check the box at Default
Setting.
Extra Image Count
You can add 100 extra images to each Data-Set.
ETC
Extra image Count You can add up to 100 extra images
Print Hospital Logo Hospital/Clinic logo when you print gallery
Print Tail String The phrase which will appear on every print
-Thiet lap mac nh
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Xac nh nh dang hnh anh c s dung trong chng trnh. Bay gi, V-ceph 5.5 ho tr nh dang hnh BMP/JPEG.
Trong hp co cac van e xay ra trong qua trnh s dung Vceph, hay s dung tuy chon nay e tm ra nguyen nhan.
Xac nh ty le nen hnh anh c s dung trong chng trnh.
Khi ma may X-quang ky thuat so a tr nen pho bien ngay nay, van e ty le phong ai cua film gia lantrc va lan gan ay a tr thanh van e. Bang chc nang nh c bang tay c thc hien mot lan, ban
thiet at ty le phong to la mac nh. Sau khi nh c, click "Set Default Size" va kiem tra hop "DefaultSetting"
Ban co the bo sung 100 hnh anh phu them vao moi Data-Set
Ban co the bo sung len en 100 hnh anh phu them
Behj
Logo benh vien/phong kham khi ban in tap anh
Cum t se xuat hien moi lan in
-
8/22/2019 Vceph6.0 Manual Viet Osstem
41/151
41414141 VVVV----cephcephcephceph
Patient Directory The folder location all the data are stored
Use Digitaize Check the box if you are a tablet user
Ruler Check the box and ruler is visible on the frame of filmMedian Filter Check the box to smooth the rough image
Use Today Check the box to get Today Pop Up
B. Analysis Setting
To set the analysis.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
V tr th muc ma tat ca d lieu c lu tr
Kiem tra hop neu ban la ngi s dung bang
anh dau vao hop va thc th hien th tren khung cua film
anh dau hop va thc th hien th tren khung cua film
anh dau vao hop e lam nhan hnh anh tho rap
anh dau vao hop e co "Ngay nay so xuong"
Thiet lap phan tch
Thiet lap phep phan tch
-
8/22/2019 Vceph6.0 Manual Viet Osstem
42/151
42424242 VVVV----cephcephcephceph
C. Chart Setting
To set the line color or font of chart.
D. VTO/STO Setting
During VTO/STO setting, the color of the structure displayed on the screen can be selected. The coloring of
the inside teeth and tracing can also be decided.
Trong khi thiet lap VTO/STO, co the chon c mau sac cua cau truc hien th tren man hnh. Cung co the
quyet nh mau sac cua rang va vet ben trong.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Thiet lap bieu o
Thiet lap ma vach hoac font cua bieu o
Thiet lap VTO/
-
8/22/2019 Vceph6.0 Manual Viet Osstem
43/151
43434343 VVVV----cephcephcephceph
E. Gallery Format Setting
You can easily make gallery format for consult to your patient or for presentation on the basis of the images
input in Data-Set. You can select gallery format just by clicking it.
When you need your customized gallery form beyond 23 galleries, you can make it easily with Report
system.
On Gallery button click right button on mouse, you can open Gallery Format Setting with popup menu.
Ban co the de dang lam nh dang trng bay e benh nhan cua ban tham khao hay e trnh bay nhng hnh
anh c ban trong Data-Set. Ban co the chon nh dang phong trng bay bang cach nhap chuot vao no.
Tren nut Gallery, bam phai chuot, ban co the m Gallery Format Setting bang menu so xuong.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Thiet lap nh dang tap anh
khi ban can tap anh tuy chnh rieng t hn 23 tap anh, ban co the lam de dang bang Report
-
8/22/2019 Vceph6.0 Manual Viet Osstem
44/151
44444444 VVVV----cephcephcephceph
F. Superimposition Setting
6 kinds of Superimposition are provided as Default. In need, you can make your own Superimposition in
Superimposition Setting.
6 loai Xep chong c cung cap mac nh. Khi can, ban co the tao mot phan xep chong rieng cuamnh trong Superimposition Setting.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
45/151
45454545 VVVV----cephcephcephceph
G. Magnify Setting
Magnifier helps your digitizing on film. You can locate landmarks more easily and accurately with magnified
image of region you are interested in.
Mode 1 Mode 2 Mode 3
magnified area follow mouse cursors
position
magnified area is on the corner of the
window
magnified area will be shown on
a separate window
H. Set Landmark Activation
For tracing, the sequence of the landmark to be inputted can be set.
May phong ai giup s so hoa cua ban tren phim. Ban co the nh v cac moc mot cach de dang va chnh
xac vi hnh anh c phong ai cua vung ban thch.
Khu vc c phong ai pha div tr con tro
Khu vc c phong ai tren goc caso
Khu vc c phong ai se hientren mot ca so rieng biet
e ve o lai, co the thiet lap chuoi cot moc se c nhap vao
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
46/151
46464646 VVVV----cephcephcephceph
-
8/22/2019 Vceph6.0 Manual Viet Osstem
47/151
47474747 VVVV----cephcephcephceph
I. Change Axis Option
The film is slanted; thus, if the baseline of the tracing is inappropriate, revision can be done with just a simple
click. FH and SN-7 are basically provided as baseline. Based on the two points designated by the user, abaseline can be simply set as well.
J. Setting the Soft Tissue Ratio
The user can randomly set the ratio of soft tissue movement according to the movement of the handler.
Hnh anh b xeo; do o, neu ng ranh gii cua hnh khong thch hp, th can phai xem xet lai ch bang 1 cai
click n gian. Ve c ban, FH va SN-7 c bo tr dang nhng ng chuan. Da tren 2 iem c ch nhbi ngi s dung, mot ng chuan cung c thiet lap mot cach n gian.
Ngi s dung co the thiet lap ngau nhien ty le dch chuyen cua mo mem theo s dch chuyen cua ngi ieu khien.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
48/151
48484848 VVVV----cephcephcephceph
) Briefing
The Pen function on the screen can be used for consulting with patients or presentations.
Once activated, the Briefing function can be used anytime.
Pressing and holding this button causes the following screen to appear:
Pen: It allows writing and indicating on the main screen. (the color and font are changeable)
Highlighter : It enables writing and indicating on the main screen with highlight color. (the color and font
are changeable)
Chc nang viet tren mang hnh co the c s dung e tham van benh nhan hoac cac dang trnh bay.
Mot khi c kch hoat, chc nang Briefing co the c s dung bat ky luc nao.
An va gi nut nay th man hnh se xuat hien nh di ay:
Cho phep viet va bieu th len man hnh chnh. (Mau sac va font ch la co the thay oi)
Co the viet va bieu th len man hnh chnh co mau sac c to noi bat. (Mau sac vafont co the thay oi)
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
49/151
49494949 VVVV----cephcephcephceph
Option: It allows color and thickness change.
Pressing this button disables the briefing function.
The text and marks written on the screen during briefing are not saved to the Vceph program.
2.4 Print
In V-ceph 4.0, you can print the screens, part of them, or slides that you see. As V-ceph enables 100% scale
printing of tracing data, you can compare a printing with its film.
Chu y: Cho phep thay oi mau va be day
An va gi nut nay e tat chc nang briefing.
Van ban hoac dau hieu tren man hnh trong qua trnh briefing khong c lu vao chng trnh V ceph.
Trong chng trnh V-ceph 4.0, ban co the in toan bo hay mot phan man hnh, hay in 1 slide. V V-ceph
co ty le in 100% hnh anh, ban co the so sanh ban in vi film cua no
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
50/151
50505050 VVVV----cephcephcephceph
The use of Batch Print enables repetitive printing for every patient.
1 0 0 % S c a l e
O p t i o n f o r p r i n t i n g
La chon in theoty le 100%
S dung chc nang Batch Print e in lap i lap lai cho moi benh nhan.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
51/151
51515151 VVVV----cephcephcephceph
3 Main Functions
3.1.1 Toolbar & Icon reference Icon
) Digitize
With the icon, you can trace with mouse or digitizer.
-Chc nang chnh
Thanh cong cu va bieu tng tham chieu
So hoa
Vi bieu tng nay, ban co the o hoa bang chuot hoac so hoa.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
52/151
52525252 VVVV----cephcephcephceph
) Correction
With the icon, you can correct Tracing.
) Align to Photo
With the icon, you can align Cephalogram to photo.
) Click Zoom
With the icon, you can zoom in by clicking mouse.
) Rect Zoom
With the icon, you can zoom in by dragging rect.
) Actual Size
With the icon, you can reset the magnified image.
) Pan
With the icon, you can move the location within the magnified image. When the curser changes to
a hand shape, you can move the location as you wish with clicking the left mouse button on.
) Image Enhancement
With the icon, you can adjust the brightness and contrast of film image. This function is necessary
when you trace on the faint film.
) Axis Change
This button allows the modification of the X axis of X-ray. The default value is FH line, and it can
be revised using the Change Axis option.
) Toggle Tracing
With the icon, you can make tracing line visible or invisible.
) Frontal Film
With the icon, you can see Frontal Film on the activated window. With one more click, only tracing
line is shown with the image invisible.
) Frontal Photo
With the icon, you can see Frontal Photo on the activated window. With one more click, only
tracing line is shown with the image invisible.
Vi bieu tng nay, ban co the o hoa ng vach lai cho chnh xac.
Vi bieu tng nay, ban co the thay oi kch thchnh anh bang chuot.
Vi bieu tng nay, ban co the thay oi kch thc bangcach keo hnh ch nhat
Vi bieu tng nay, ban co the thiet lap lai hnh anh c phong ai
Vi bieu tng nay, ban co the ieu chnh o sang va o tng phan cua hnh anh film. Chc nang nayla can thiet khi ban ra tren film m nhat.
Bieu tng nay cho phep cai bien truc X cua tia X-Quang. Gia tr mac nh la ng FH, va no cothe chnh sa bang cach s dung tuy chon Change Axis.
Vi bieu tng nay, ban co the truy tm ng nhn thay hay khong nhn thay.
Vi bieu tng nay, ban co the thay Frontal Film tren ca so c kch hoat. Bang 1 cai click na, chco nhng ng vien tm kiem mi the hien ra vi hnh anh bien mat.
Vi bieu tng nay, ban co the thay Frontal Photo tren man hnh c kch hoat. Vi 1 cai clickna, ch co nhng ng vien tm kiem mi the hien ra vi hnh anh bien mat.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
Vi bieu tng nay, ban co the xep thang hangbieu o chup au vi hnh anh
Vi bieu tng nay, ban co the di chuyen v tr trong pham vi hnh anh c phong ai. Khi con trochuyen sang hnh ban tay, ban co the di chuyen v tr nh ban muon bang cach nhap chuot trai len no.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
53/151
53535353 VVVV----cephcephcephceph
) Lateral Film
With the icon, you can see Lateral Film on the activated window. With one more click, only tracing
line is shown with the image invisible.
) Lateral Photo
With the icon, you can see Lateral Photo on the activated window. With one more click, only tracing
line is shown with the image invisible.
) Panorama
With the icon, you can see Panorama film on the activated window.
16) Model Photo
With the icon, you can see a Model Photo automatically made into 5 image set in Data-Set.
17) IntraOral Photo
With the icon, you can see an Intraoral Photo automatically made into 5 image set in Data-Set.
3.1.2 Toolbar
With Toolbar you can easily operate functions for diagnosis and counsel
) VTO / STO
With the icon, you can simulate the process of treatment. And also you can
show your patient the simulated image before treatment
) Growth Forecast
With the icon, you can forecast a patients features after he/she grows.
) Superimposition
With the icon, you can compare data. V-ceph provides six Superimpositions of
Ricketts analysis as a default. And also you can compose your own
Superimposition in Option mode.
) Gallery
With the icon, you can see the selected gallery in Gallery Format Setting.
) Chart
With the icon, you can see the Polygonal Chart. If you change Analysis, the
chart changes according to analysis method.
) Image Fusion
With the icon, you can see the Film overlapped with Photo
Vi bieu tng nay, ban co the thay Lateral Film tren man hnh c kch hoat. Vi 1 cai click
na, ch co nhng ng vien tm kiem mi the hien ra vi hnh anh bien mat.
Vi bieu tng nay, ban co the thay Lateral photo tren man hnh c kch hoat. Vi 1 cai clickna, ch co nhng ng vien tm kiem mi the hien ra vi hnh anh bien mat.
Vi bieu tng nay, ban co the thay Panorama Film tren ca so c kch hoat.
Vi bieu tng nay, ban co the thay mot Model Photo c chuyen mot cach t ong thanhbo 5 hnh anh trong Data-set
Vi bieu tng nay, ban co the thay mot Intraoral Photo (anh trong mieng) c chuyenmot cach t ong thanh bo 5 hnh anh trong Data-set
Vi thanh cong cu, ban co the de dang thc hien chc nang chan oan va t van.
Vi bieu tng nay, ban co the mo phong qua trnh ieu tr. Va ban cungco the cho benh nhan xem hnh anh c mo phong trc khi ieu tr.
Vi bieu tng nay, ban co the d oan cac ac iem cua benh nhan sau khi ho
ln len
Vi bieu tng nay, ban co the so sanh d lieu. V-ceph cung cap 6 hnh anh xepchong cua phep phan tch Rickett dang mac nh. Va ban cung co the soan ranhng hnh anh xep chong cua rieng mnh trong phan Option.
Vi bieu tng nay, ban co the thay tap anh c chon trong Gallery Format
Vi bieu tng nay, ban co the thay bieu o nhieu canh. Neu ban thay oicach phan tch, bieu o cung thay oi theo.
Vi bieu tng nay, ban co the thay Film e len Photo
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
54/151
54545454 VVVV----cephcephcephceph
3.2 How to Digitize
You can digitize directly with X-ray Film on monitor screen. Or by using digitizer (tablet), you can input thetracing data drawn in hand.
The length information is accurate when you input the image from scanner at 100% scale. But when you take
a picture by Digital Camera, you have to input image length with Set Image Size function.
With the icon, start Digitizing.
3.2.1 Select a mode
Select Digitize with X-ray Film, then Digitizing starts as below.
* Digitize with X-ray Film : the mode that you trace directly on film image on your monitor.* Digitize using tablet without X-ray film : the mode that you trace with digitizer without x-ray image.
Cach so hoa
Ban co the so hoa vi Film X-Quang tren man hnh chnh. Hay s dung bo so hoa (bang), ban co thethem vao d lieu tm kiem c ve bang tay.
Thong tin o dai la chnh xac khi ban nhap hnh anh t may scan ty le 100%. Nhng khi ban chup hnhbang may anh ky thuat so, ban phai nhap chieu dai hnh anh bang chc nang Set Image Size
Vi bieu tng nay, bat au so hoa.
La chon sau o, s so hoa bat au nh ben di
phng thc ma ban co the ve trc tiep len hnh anh film tren man hnhphng thc ma ban co the truy tm vi bo so hoa makhong can hnh chup X-Quang
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
55/151
55555555 VVVV----cephcephcephceph
For more accurate tracing, V-ceph 5.5 provides magnify cursor function.
Mode 1 Mode 2 Mode 3
magnified area follow mouse cursors
position
magnified area is on the corner of the
window
magnified area will be shown on a
separate window
e viec vach, ke chnh xac hn, V-ceph 5.5 cung cap chc nang con tro phong ai
Khu vc phong ai pha di v trcon tro
Khu vc phong ai nam goc cuaca so
Khu vc phong ai se xuat hien mot ca so tach biet.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
56/151
56565656 VVVV----cephcephcephceph
3.2.2 Determine Landmarks on Lateral View
0 Sella Center of Sella Turica
1 PorionThe midpoint of the upper edge of the porus augusticus externus located by means
of the metal rods on the cephalogram
2 Basion Most inferior point of the Occipital bone
3 Hinge Axis Center of rotation of the Condyle
4 Pterygoid Eleven oclock position of the Pterygoid fissure
5 Nasion V notch of frontal, and nasal bones
6 Orbital Most inferior point of the Orbital contour
7 ANS Tip of the anterior nasal spine
8 PNS Tip of the posterior nasal spine
9 A-point Deepest point between ANS, and the upper incisal alveolous
10 B-point Deepest point between Pogonion, and lower incisal alveolus
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
57/151
57575757 VVVV----cephcephcephceph
11 PM Point where cuvature changes between B-point and Pogonion
12 Pogonion Most anterior point of the Symphysis
13 Menton Most inferior point on the symphyseal outline
14 Corpus left Left point of a tangent of the inferior border of the Corpus
15 Ramus down Lower point of a tangent of the posterior border of the Ramus
16 Articulare Intersection of inferior cranial base surface and posterior surface of Condyle
17 R3 Most inferior point of the Sigmoid notch of the Ramus
18 R1 Deepest point on the curve of the anterior border of the Ramus
19 Mx 1 crown Tip of the crown of the upper incisor
20 Mx 1 root Tip of the root of the upper incisor
21 Md 1 crown Tip of the crown of the lower incisor
22 Md 1 root Tip of the root of the lower incisor
23 Occl. Plane Midpoint between upper, and lower 1st
Bicuspids or Incisors
24 Mx 6 distal Distal contract point of maxillary first molar
25 Mx 6 root Distal buccal root of maxillary first motar
26 Md 6 distal Distal contact point of mandibular first molar
27 Md 6 root Distal root of mandibular first molar
-
8/22/2019 Vceph6.0 Manual Viet Osstem
58/151
58585858 VVVV----cephcephcephceph
3.2.3 Lateral Trace Guide Window
The below is Guide window, which shows standard landmark position. Trace according to red point on the
Guide window.
3.2.4 Digitize Window Digitizing Toolbar reference
The below window shows the buttons for digitizing.
L a n d m a r k t o b e m a r k e d
Ben di la ca so ch dan, no the hien v tr moc c ban. Ve theo iem mau o tren ca so hngdan
Ca so ben di the hien cac nut e so hoa
Moc se c anh dau
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
59/151
59595959 VVVV----cephcephcephceph
) Back
With the icon, you can cancel just digitized point and go back to previously digitized point. Byclicking the right mouse button, you can do the same Back function.
) Cancel
With the icon, you can cancel all tracing and then go out of this tracing window.
) Restart
With the icon, you can trace newly.
) Save & Finish
With the icon, you can stop tracing in the middle of work. In order to complete tracing, add
remained landmarks and profiles in Correction mode.
) Image Enhancement One-click Image Enhancement
With the icon, you can enhance film image with Soft-Tissue outstanding. With
one more clicking, you can reset to the original image.
3.2.5 Drawing Upper & Lower Profiles by Digitizing Points
Even for a person used to computer, it is difficult to draw a curved line on the screen. So, V-ceph 5.5
provides you with easy method for drawing upper & lower profile by digitizing several points.
Vi bieu tng nay, ban co the huy iem so hoa va quay tr lai iem so hoa trc o.Bang cach nhap chuot phai, ban co the lam tng t chc nang Back.
Vi bieu tng nay, ban co the huy tat ca ng ve va sau o thoat khoi ca so
Vi bieu tng nay, ban co the phac hoa mi.
Vi bieu tng nay, ban co the dng ve khi ang lam viec. e hoan tat viec phac hoa, themmat va moc con lai trong phng thc Correction.
Vi bieu tng nay, ban co the lam cai thien hnh anh film vi s noi bat cuamo mem. Vi viec them 1 cu nhap chuot, ban co the quay lai hnh anh goc.
Tham ch vi ngi a quen s dung may tnh, rat kho e co the ve c nhng ng cong tren man hnh.V vay, V-ceph 5.5 cung cap cho ban phng phap de dang cho viec ve mat ham tren va ham di bangmot vai iem so hoa
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
60/151
60606060 VVVV----cephcephcephceph
Digitizing points on the soft-tissue are shown on Trace Guide.
When digitizing points is finished, the profiles are created automatically as below.
3.2.6 Auto Tracing
Structures such as Maxilla, Symphysis, Mandible etc are drawn automatically during digitizing. You can turn
this function off by unchecking Auto Tracing(Preference
Analysis Setting) option.
iem so hoa tren mo mem c the hien tren Trace Giude.
Khi cac iem so hoa ket thuc, be mat c tao ra mot cach t ong nh ben di.
Nhng cau truc nh ham tren, khp ban ong, ham di... c ve mot cach t ong trong suot qua trnh sohoa. Ban co the tat chc nang nay bang cach bo dau kiem tuy chon "Auto Tracing" (Preference -> AnalysisSetting)
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
61/151
61616161 VVVV----cephcephcephceph
3.2.7 Drawing Extra Line
You can draw three extra lines when you need. If no need, just click Finish button on Digitize Window. And
then tracing will be completed.
Whenever you want to input Extra Line again, you can re-start clicking ADD in Correction mode.
* You can draw 3 extra lines as default. If you want, use V-analysis to add other lines.
Ban co the ve 3 ng phu them neu ban can. Neu khong can, ch can click nut 'Finish' tren ca soDigitize. Va sau o viec ve hoan tat.
Bat c khi nao ban muon nhap lai ng phu them, ban co the bat au lai bang cach nhap ADD trongphng thc Correction.
Ban co the ve 3 ng phu them dang mac nh. Neu muon, ban co the s dung V-analysis e them cac ng khac.
Edited by Foxit ReaderCopyright(C) by Foxit Software Company,2005-2008For Evaluation Only.
-
8/22/2019 Vceph6.0 Manual Viet Osstem
62/151
62626262 VVVV----cephcephcephceph
-
8/22/2019 Vceph6.0 Manual Viet Osstem
63/151
63636363 VVVV----cephcephcephceph
3.3 How to Correct