vacuum air tube 42 - diebold.com · by the owner's e.c. for vat 42 (1) 25mm (1") conduit...
TRANSCRIPT
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
PA
GE 1 O
F 7
L1128
(DIM
EN
SIO
NS I
N F
EE
T A
ND I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
CALL 1-800-999-3600
FIL
E N
O. 178-2
100 R
EV. 5
15163 OPERATOR UNIT
SEND RECALL
SYSTEM SWITCHED "ON"
PLAN VIEW
FRONT VIEW SIDE VIEW
98
")8
7(3
270
")16
5(2
59
")8
5(1
0
83
")41(3
83
")41(3
165
")21(6
")8
5(1'-8
524
")4
1(1
32
(3'-2")
965
")85(10
270")85(
16
")165(2
59
CONTROL BOX PLUG IS NOT A SUITABLE DISCONNECT.
(1) RECEPTACLE REQUIRED FOR EACH OPERATOR UNIT.
SINGLE-PHASE, 20 AMP DEDICATED BRANCH CIRCUIT.
"SWITCHED" DUPLEX OUTLET ON 120 VAC, 60HZ,
OWNER'S ELECTRICAL CONTRACTOR TO PROVIDE
PERSPECTIVE
FRONT COVER
REMOVABLE
"RECALL" BUTTON"SEND" BUTTON
98
")87(3
OPERATOR UNIT CONTROL BOX
LE
VE
LIN
G A
DJ
US
TM
EN
T 0"
TO 2
5m
m (1")
SEND BUTTON
RECALL BUTTONTYPICAL TRANSACTION
BLOWERS DE-ENERGIZE AND CUSTOMER UNIT DOOR OPENS
BLOWERS ENERGIZE. THE CARRIER ARRIVES AT THE CUSTOMER UNIT,
IN THE TELLER UNIT AND THE TELLER PRESSES THE SEND BUTTON, THE
WHEN THE TELLER COMPLETES TRANSACTION, THE CARRIER IS PLACED
AND OPERATOR UNIT DOOR OPENS.
CARRIER ARRIVES AT THE TELLER UNIT, THE BLOWERS DE-ENERGIZE
CUSTOMER UNIT DOOR CLOSES AND THE BLOWERS ENERGIZE. THE
INSIDE CARRIER, THEN PLACES CARRIER INTO CUSTOMER UNIT. THE
AND THE CARRIER PRESENT. THE CUSTOMER PLACES TRANSACTION
CUSTOMER ARRIVES AT THE CUSTOMER UNIT, WITH DOOR OPEN
OPERATOR PRESSES SEND TO DELIVER CARRIER TO CUSTOMER UNIT.
CUSTOMER UNIT DOOR OPENS AND CLOSES, AND UNIT IS READY.
COUNTERTOP
UNIT AND
ATTACHED TO
SUPPORT ANGLE
POWER CORDS
1829mm (6-0") LONG
CCTV CABLES
BY THE OWNER'S E.C. FOR OPTIONAL
(1) 25mm (1") CONDUIT IF REQUIRED
CONTROL AND AUDIO CABLES, AND
BY THE OWNER'S E.C. FOR VAT 42
(1) 25mm (1") CONDUIT IF REQUIRED
COUNTERTOP
LISTINGS AND APPROVALS
GENERAL REQUIREMENTS (CANADA)
INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1:
CAN/CSA-C22.2 NO. 60950-1
GENERAL REQUIREMENTS (UNITED STATES)
INFORMATION TECHNOLOGY EQUIPMENT-SAFETY-PART 1:
ASNI/UL 60950-1
NORTHBROOK, IL 60062-2096
333 PFINGSTEN ROAD
CORPORATE HEADQUARTERS
UNDERWRITERS LABORATORIES (UL)
329
")16
15
(1'-0
256
")8
7(2'-0631
")16
1(1
0
INSTALLATION BASE DETAILS
15163 OPERATOR UNIT DETAILS
VACUUM AIR TUBE 42 - 114mm (4.5") DIA. TUBE SYSTEM
**
*
PR
OJE
CTIO
N
THIR
D A
NG
LE
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PA
GE 2 O
F 7
(DIM
EN
SIO
NS I
N F
EE
T A
ND I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
FIL
E N
O. 178-2
100 R
EV. 5
OPERATOR CONTROL PANEL:
INSTALLATIONS UNLESS DICTATED BY CODE
ARE NOT REQUIRED FOR CULVERT
BURIED TUBING INSTALLATIONS. CONDUITS
OWNER'S E.C. TO PROVIDE CONDUITS FOR
SEND RECALL
OPERATOR POWER :
CONTROL BOX PLUG IS NOT A SUITABLE DISCONNECT.
CIRCUIT. (1) RECEPTACLE REQUIRED FOR EACH OPERATOR UNIT.
OUTLET ON 120 VAC, 60HZ, SINGLE-PHASE, 20 AMP DEDICATED BRANCH
OWNER'S ELECTRICAL CONTRACTOR TO PROVIDE "SWITCHED" DUPLEX
RECALL CARRIER BUTTON (RED):
SEND CARRIER BUTTON (GREEN):
FLOOR OPENING DETAILS
(6")
152 318
")21(1'-0 (1'-7")
483
(8")
203
(5")
127
(3")
76
PLAN VIEW PLAN VIEW PLAN VIEWTWO OPERATOR UNITS THREE OPERATOR UNITSSINGLE OPERATOR UNIT
USE OF VIDEO IS OPTIONAL, AND MAY NOT BE REQUIRED.
TYPICAL 25mm (1") CONDUIT FOR VIDEO CABLES.
CONTROL AND AUDIO CABLES
TYPICAL 25mm (1") CONDUIT FOR VAT 42
UNIT DOOR SLIDES TO THE OPEN POSITION TO PRESENT THE CARRIER.
THE CUSTOMER UNIT. UPON ARRIVAL AT THE OPERATOR UNIT, THE OPERATOR
WHEN PRESSED, THE CARRIER IS BROUGHT TO THE OPERATOR UNIT FROM
PRESSED TO RETURN CARRIER TO THE CUSTOMER UNIT.
THE CARRIER IS RETURNED TO OPERATOR UNIT AND THE SEND BUTTON IS
(4")
102
FLOOR OPENING
(8")
203DETERMINED BY COUNTERTOP DEPTH
") FROM EDGE OF COUNTERTOP 4132mm (1
LOCATE FRONT EDGE OF FLOOR OPENING
SIDE VIEW - FLOOR OPENING
(3")
76
(3")
76
(3")
76
")21(6
165
(3")
76
(3")
76
")21(6
165
")21(6
165
(3")
76
M2 ELITE
PNEUMATIC TUBE SYSTEM
MODEL ELCP - PTD
120 VAC 3 AMP 60HZ
POWER TELLER DOOR
CONTROL UNIT with
WIRING DIAGRAM E-12648
WIRING DIAGRAM E-12650
WIRING DIAGRAM E-12658
FOR SERVICE CALL 800-237-8261
Eagle Pneumatic, Inc. Lakeland, Florida 33811
ES
UF ES
UF
ESUF
GR
EE
N
GR
OU
ND
TE
LLE
R
BL
OW
ER
RE
MO
TE
CO
NT
RO
L
TE
LLE
R
MO
TO
R
DO
OR
CU
ST
OM
ER
MO
TO
R
DO
OR
TE
LLE
R
CO
NT
RO
L
CU
ST
OM
ER
MAX 3 AMP
TOP
BACK
FRONT
BOTTOM
SIDESIDE
79
")81(3
3 AMP FUSE
165
")21(6
159
")41(6
79
")8
1(3
271
")16
11
(10
")16
13
(
21
")2
1(9
241
")8
3 (
10
159
")41(6
")167(1
36
")83(3
86")167(1
36
")85(
16
")81(2
54")85(
16
259
")16
3(1
0271
")16
11
(10
")8
3 (
10
")2
1(9
241
")16
13
(
21
(11")
279
NOTE:
LOCATE OUTLET WITHIN 1829mm (6'-0") OF CONTROL BOX.
CIRCUIT (RECOMMENDED).
SINGLE-PHASE, 20AMP DEDICATED SWITCHED BRANCH
OWNER'S E.C. TO PROVIDE (1) 120V., 50/60 Hz.,
POWER CORD 1829mm (6'-0") LONG.
COLOR/MATERIAL :
STAINLESS STEEL
BRACKET AND FRONT COVER
TWO PIECE CONTROL BOX CONSISTS OF BACK MOUNTING
BACK MOUNTING BRACKET
STAINLESS STEELFRONT COVER
POWER CORD 1829mm (6'-0") LONG.
SPECIFICATIONSONE CONTROL BOX REQUIRED FOR EACH OPERATOR UNIT
CABLE CONNECTIONS AND SERVICE)
ADEQUATE SPACE AROUND OR BETWEEN CONTROL BOXES FOR
WALL (IF POSSIBLE) IN AREA BEHIND KNEE SPACE PANEL. (ALLOW
RECOMMENDED LOCATION OF CONTROL BOX TO BE MOUNTED ON
THE CONTROL BOX.
CONSTRUCTION AND ADEQUATE TO SUPPORT WEIGHT OF
MOUNTING HARDWARE TO BE COMPATIBLE WITH WALL
1.8kg (4 LBS.)
WEIGHT (APPROXIMATE):
LOCATE OUTLET WITHIN 1829mm (6'-0") OF CONTROL BOX.
CIRCUIT (RECOMMENDED).
SINGLE-PHASE, 20AMP DEDICATED SWITCHED BRANCH
OWNER'S E.C. TO PROVIDE (1) 120V., 50/60 Hz.,
35
")83(1
35
")21(3
89
")83(1
")1611(
17")81(2
54
")1611(
17
(91-200189-0062) OPERATOR CONTROL
8 CONDUCTORS, FOIL SHIELD, PLENUM
#22 GAUGE STRANDED BARE COPPER, OPERATOR GROUND
PLENUM, RED JACKET (91-200204-0062)
14 GA., 2 CONDUCTOR. COPPER, SOLID,
(91-200189-0062) CUSTOMER CONTROL
8 CONDUCTORS, FOIL SHIELD, PLENUM
#22 GAUGE STRANDED BARE COPPER,
15164 VAT 42 CONTROL BOX
CUSTOMER CONTROL
UNSHIELDED, CMR (41-027368-0-00-A)
#16 GAUGE - 3 CONDUCTOR, BC,
CUSTOMER CONTROL
UNSHIELDED, CMR (41-027368-0-00-A)
#16 GAUGE - 3 CONDUCTOR, BC,
FIL
E N
O. 178-2
100 R
EV. 5
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
PA
GE 3 O
F 7
(DIM
EN
SIO
NS I
N F
EE
T A
ND I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
CALL 1-800-999-3600
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
PA
GE 4 O
F 7
(DIM
EN
SIO
NS I
N F
EE
T A
ND I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
CALL 1-800-999-3600
AS R
EQ
UIR
ED
(2'-6")
762 M
INIM
UM
llaC
COLOR DISPLAY AND MOUNTING
OUTLINE OF OPTIONAL 380mm (15")
835 SHOWN
")87(2'-8
CAN VARY
CAN VARY
NOTES:
1.
DISTRIBUTION GUIDELINES.
FOR POWER CONSOLIDATION AND
SEE CUT SHEET FILE NUMBER 178-1953
2.
3.
327
")87(1'-0
334
")81(1'-1
260
")4
1(1
0
124
")2
1(1'-5
445
")8
7(4
SPEAKER
MICROPHONE
769
")4
1(1
0260
")4
1(2'-6
TRAFFIC FLOW
0000000
PLAN VIEW
FRONT VIEWSIDE VIEW
124
")87(4
relleT
(4'-4")
1321 R
EC
OM
ME
ND
ED
CUSTOMER UNIT TEMPLATE / INSTALLATION BASE DETAILS
15160, 15161 & 15162 CUSTOMER UNIT DETAILS - DOWNSEND
VACUUM AIR TUBE 42 - 114mm (4.5") DIA. TUBE SYSTEM
15160 CUSTOMER UNIT
WITH INSTALLATION/SERVICE AREA.
BY OWNER. BOLLARDS SHOULD NOT INTERFERE
OF VAT UNIT. SIZE AND LOCATION AS REQUIRED
(2) BOLLARDS RECOMMENDED ON APPROACH SIDE
15161 CUSTOMER UNIT WITH CAMERA
15162 CUSTOMER UNIT WITH CAMERA & 254mm (10.4") DISPLAY
15162 UNIT ONLY
DISPLAY PANEL
STEEL TEMPLATE/INSTALLATION BASE
EDGE OF ISLAND TO FRONT FACE OF
164
")167
(6
164
")167
(6
149
(1'-3")
381
")87
(5
(1")
25
(11")
279(1")
25
THESE CODES.
FOR ANY CHANGES NECESSARY TO COMPLY WITH
ELECTRICAL CONTRACTOR TO BE RESPONSIBLE
CODES WHICH MAY BE APPLICABLE. OWNER'S
THE NATIONAL, ALL STATE, AND LOCAL ELECTRICAL
ALL WORK AND MATERIALS SHALL CONFORM TO
ELECTRICAL CONTRACTOR.
BE PROVIDED AND INSTALLED BY THE OWNER'S
AND OVERLOAD PROTECTION DEVICES, ARE TO
ALL CONDUIT, POWER WIRES, JUNCTION BOXES,
UNITS ONLY
IN 15161 AND 15162
CAMERA SUPPLIED
SEE PAGE 5 OF 5
CUSTOMER CONTROLS
(1'-10")
559
(1")
25
(2'-0")
610
MINIM
UM IS
LA
ND
INSTALL AND SERVICE UNIT
CLEAR AREA REQUIRED TO
SEE FILE #178-2111 FOR DETAILS
WITH 15160 CUSTOMER UNIT
COLOR DISPLAY AND MOUNTING USED
OUTLINE OF OPTIONAL 380mm (15")
(3'-5")
1041
")4
3(4'-6
1391
(6")
152
OF O
PTIO
NA
L 3
80
mm (15") C
OL
OR DIS
PL
AY
MA
XIM
UM B
OLL
AR
D H
EIG
HT I
N F
RO
NT
*
*
(10")
254 SHOWN
")87(1'-0
327
(10")
254
MINIMUM
OF VAT UNIT BY THE OWNER.
OPTIONAL BOLLARDS ON EXIT SIDE
WHEN 380mm (15") DISPLAY IS INSTALLED.
OPTIONAL BOLLARDS BY THE OWNER
DISPLAY IS INSTALLED.
380mm (15") COLOR
BY THE OWNER WHEN
OPTIONAL BOLLARDS
937
(3")
76
")8
7(3'-0
NEPO
ROOD
reirraC
dneS
1276
")4
1(4'-2
254mm (10") - PART #15183
178mm (7") - PART #15182
INCREASE VAT 42 CUSTOMER UNIT HEIGHT:
OPTIONAL TRUCK BASES AVAILABLE TO
INSTALLATIONS.
(SEE DETAILS). REQUIRED FOR ALL NEW
BY OWNER'S GENERAL CONTRACTOR
DIEBOLD NIXDORF, LOCATED AND INSTALLED
INSTALLATION BASE FURNISHED BY
CUSTOMER UNIT STEEL ISLAND TEMPLATE /
BASE
UNIT
UNIT BASE
")161(1
27
")21(9
241
")161(1
27
TEMPLATE
FIL
E N
O. 178-2
100 R
EV. 5
**
*
PR
OJE
CTIO
N
THIR
D A
NG
LE
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PA
GE 5 O
F 7
(DIM
EN
SIO
NS I
N F
EE
T A
ND I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
FIL
E N
O. 178-2
100 R
EV. 5
CUSTOMER CONTROL PANEL
OPERATOR MUST SEND THE CARRIER TO THE CUSTOMER UNIT.
AND ACCESSIBLE. IF THE CARRIER IS AT THE OPERATOR STATION, THE
AN ARRIVING CUSTOMER WILL USUALLY FIND THE CARRIER VISIBLE
WISHES TO COMMUNICATE.
THE OPERATOR STATION TO ALERT THE OPERATOR THAT A CUSTOMER
MAY PRESS THE "CALL" BUTTON. THIS ACTIVATES AN AUDIO CHIME AT
WHEN A CUSTOMER ARRIVES AT THE CUSTOMER UNIT, THE CUSTOMER
CUSTOMER UNIT AND IS SENT AND DELIVERED TO THE OPERATOR UNIT.
PRESSES THE "SEND" BUTTON. THE CARRIER IS PULLED UP INTO THE
CARRIER, THE CUSTOMER RETURNS THE CARRIER TO THE CRADLE AND
AFTER THE CUSTOMER PLACES THE TRANSACTION MATERIALS INTO THE
TRAFFIC
FLOW
PERSPECTIVE
NOTE:
L TUBE
") DIA. PNEUMATIC 21
C 114mm (4
(3")
76
(7")
178
FRONT VIEW SIDE VIEW
(2")
51
(5")
127
149
(1'-3")
381
")87(5
(2'-0")
610
MINIMUM ISLAND
(BY OWNER'S E.C.) FOR CCTV CABLES.
OPTIONAL 25mm (1") DIA. CONDUIT
FOR CONTROL AND AUDIO CABLES.
25mm (1") DIA. CONDUIT (BY OWNER'S E.C.)
OWNER'S GENERAL CONTRACTOR
SUPPORTS AS REQUIRED BY
FORMS AND STEEL TEMPLATE
INSTALLATIONS UNLESS DICTATED BY CODE
ARE NOT REQUIRED FOR CULVERT
BURIED TUBING INSTALLATIONS. CONDUITS
OWNER'S E.C. TO PROVIDE CONDUITS FOR
SIDE OF ISLAND
"FRONT" AND IS TO BE INSTALLED FACING TRAFFIC
STEEL TEMPLATE/INSTALLATION BASE IS MARKED
CALL TELLER BUTTON:
OPEN DOOR / SEND CARRIER BUTTON:
ISLAND RECOMMENDED
610mm (2'-0") MINIMUM
SINGLE-PHASE, 20 AMP DEDICATED BRANCH CIRCUIT
TO PROVIDE 25mm (1") DIA. CONDUIT AND (1) 120 VAC, 60 HZ.,
ELECTRICAL POWER-(1 PER CUSTOMER UNIT) OWNER'S E.C.
(1'-3")
381
(11")
279
(2")
51
CUT SHEET FILE NO. 178-2105
TWO-WAY CCTV SYSTEM
SEE VAT 42 TYPICAL SCHEMATIC WITH
PLAN VIEW
111 ")8
3(4
")161(1
27
")21(9
242")161(1
27
TU
BE S
TU
B O
UT
MA
XIM
UM
260
")41(10
PART NUMBER 00-155865-000A
CUSTOMER UNIT TEMPLATE / INSTALLATION BASE
ISLAND
TOP OF
TO SETTING UNIT.
AND TUBES. REMOVE PRIOR
INSTALLATION OF TEMPLATE
STEEL TEMPLATE DURING
ANGLES USED TO SUPPORT0
0
dneS
reirraC
NEPO
ROOD
llaC
relleT
296
")85(11
llaC
relleT
NEPO
ROOD
reirraC
dneS
121
")43(4
121
")43(4
")161(1
27
")21(9
242")161(1
27
CLEAR SERVICE AREA
OUTLINE OF REQUIRED
CLEAR SERVICE AREA
OUTLINE OF REQUIRED
MINIM
UM R
EC
ES
S
REQUIRED ABOVE CURB LEVEL
1576mm (5-6") MINIMUM CLEARANCE HEIGHT
FIL
E N
O. 178-2
100 R
EV. 5
FIRST LANE OR WALL RECESS INSTALLATION
15160, 15161 & 15162 CUSTOMER UNIT DETAILS
VACUUM AIR TUBE 42
00000
TRAFFIC FLOW
00000
PLAN VIEW - FIRST LANE MINIMUM CURB
PLAN VIEW - MINIMUM WALL RECESS
MINIMUM
CAN VARY
CAN VARY
000
TRAFFIC FLOW
000
(10")
254
")87(1'-0
327
(10")
254
835
")87(2'-8
MINIMUM
164
")167(6
164
")167(6 (3'-2")
965
164
")167(6
164
")167(6
MINIMUMMINIMUM
(5'-9")
1753
(1'-11")
583
(1")
25
260
")4
1(1
0
460
(3'-2")
965
")87(1'-0
327
")81(1'-6
CAN VARY
260
")4
1(1
0
124
")2
1(1'-5
445
")8
7(4
OWNER'S GENERAL CONTRACTOR TO PROVIDE SMOOTH AND LEVEL ISLAND IN AREA OF CUSTOMER UNIT
TO CLEAR UNDERGROUND PNEUMATIC TUBES
VAT 42 UNIT INSTALLED AT A BUILDING WALL MAY REQUIRE MODIFICATION TO THE FOUNDATION
SEE CUT SHEET FILE NO. 178-2102 FOR TYPICAL DRIVE-UP SCENARIOS.
BEFORE INSTALLATION
DETAILS SHOWN ARE FOR ILLUSTRATION ONLY AND ACTUAL SITE CONDITIONS MUST BE VERIFIED
THE CUSTOMER UNIT POSITIONED IN THE FIRST LANE AND/OR AGAINST THE BUILDING WALL.
DETAILS SHOWN ARE FOR VAT 42 INSTALLATIONS WHERE CUSTOMER'S SITE CONDITIONS REQUIRE
NOTE:
FOR NEW CONSTRUCTION.
RECOMMENDED LOCATIONS SHOWN
LOCATION AS REQUIRED BY OWNER'S G.C.
(2) BOLLARDS RECOMMENDED. SIZE AND
BY OWNER'S G.C.
SIZE AND LOCATION AS REQUIRED
(2) BOLLARDS RECOMMENDED.
(2'-0")
610
(2'-0")
610
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
PA
GE 6 O
F 7
(DIM
EN
SIO
NS I
N F
EE
T A
ND I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
CALL 1-800-999-3600
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
PA
GE 7 O
F 7
(DIM
EN
SIO
NS I
N F
EE
T A
ND I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
CALL 1-800-999-3600
NOT INTERFERE WITH INSTALLATION/SERVICE AREA.
SIZE AND LOCATION AS REQUIRED BY OWNER. BOLLARDS SHOULD
(2) BOLLARDS RECOMMENDED ON APPROACH SIDE OF VAT UNIT.
COLOR DISPLAY AND MOUNTING
OUTLINE OF OPTIONAL 380mm (15")
835 SHOWN
")87(2'-8
CAN VARY
CAN VARY
")2
1(2'-5
749
(1")
25
NOTES:
1.
DISTRIBUTION GUIDELINES.
FOR POWER CONSOLIDATION AND
SEE CUT SHEET FILE NUMBER 178-1953
2.
5.
124
")16
15
(2'-0633
")8
7(4
")4
3(4'-6
1391
(6")
152
TRAFFIC FLOW0000000
PLAN VIEW
FRONT VIEWSIDE VIEW
124
")87(4
ELECTRICAL CONTRACTOR.
BE PROVIDED AND INSTALLED BY THE OWNER'S
AND OVERLOAD PROTECTIONDEVICES, ARE TO
ALL CONDUIT, POWER WIRES, JUNCTION BOXES,
AND SERVICE UNIT
AREA REQUIRED TO INSTALL
15167 CUSTOMER UNIT15168 CUSTOMER UNIT WITH CAMERA
15169 CUSTOMER UNIT WITH CAMERA & 254mm (10.4") DISPLAY
164
")167
(6
164
")167
(6
260
")4
1(5
133
")4
1(1
0
136
")83
(5
266
")21
(10
MAXIMUM OFFSET
394
")2
1(1'-3
RESPONSIBILITY OF THE OWNER'S G.C.
MODIFICATION TO EXISTING ISLAND WILL BE THE
RANGE MAY REQUIRE ISLAND MODIFICATION.
OFFSET CUSTOMER UNIT. PNEUMATIC TUBES OUTSIDE THIS
FROM FRONT EDGE OF ISLAND REQUIRED TO INSTALL THE
MAXIMUM DISTANCE FOR CENTERLINE OF EXISTING TUBE
UNIT PER OWNER.
ON EXIT SIDE OF VAT
OPTIONAL BOLLARDS
4.
FOR RETRO FIT TO EXISTING PNEUMATIC TUBE SYSTEMS
15167, 15168, OR 15169 EXTENDED DEPTH CUSTOMER UNIT
VACUUM AIR TUBE 42 - 114mm (4.5") DIA. TUBE SYSTEM
") PNEUMATIC TUBE SYSTEMS.21(4
FOR USE AS A RETROFIT UNIT FOR EXISTING 114mm
THE EXTENDED DEPTH CUSTOMER UNIT IS INTENDED
APPROPRIATE FOR INSTALLATION ON EXISTING ISLAND
ISLAND WILL DICTATE WHETHER THE RETROFIT UNIT IS
LOCATION OF THE TUBE FROM THE FRONT EDGE OF THE
3.
WILL BE THE RESPONSIBILITY OF THE OWNER'S G.C.
ALL WORK AND MATERIALS TO MODIFY EXISTING ISLANDS
6.
NECESSARY TO COMPLY WITH THESE CODES.
CONTRACTOR TO BE RESPONSIBLE FOR ANY CHANGES
WHICH MAY BE APPLICABLE.OWNER'S ELECTRICAL
NATIONAL, ALL STATE, AND LOCAL ELECTRICAL CODES
ALL WORK AND MATERIALS SHALL CONFORM TO THE
(10")
254 SHOWN
")87(1'-0
327
(10")
254
AS R
EQ
UIR
ED
(2'-6")
762 M
INIM
UM
llaC
SPEAKER
MICROPHONE
relleT
(4'-4")
1321 R
EC
OM
ME
ND
ED
15169 UNIT ONLY
DISPLAY PANEL
SEE PAGE 5 OF 5
CUSTOMER CONTROLS
937
(3")
76
")8
7(3'-0
NEPO
ROOD
reirraC
dneS
1276
")4
1(4'-2
327
")87(1'-0
334
")81(1'-1
UNITS ONLY
IN 15168 AND 15169
CAMERA SUPPLIED
(3'-5")
1041
769
")4
1(1
0260
")4
1(2'-6 (3'-5")
1041
SEE FILE #178-2111 FOR DETAILS
WITH 15167 CUSTOMER UNIT
COLOR DISPLAY AND MOUNTING USED
OUTLINE OF OPTIONAL 380mm (15")
MINIMUM
WHEN INSTALLED WITH 15" DISPLAY
OPTIONAL BOLLARDS BY THE OWNER.
OF O
PTIO
NA
L 3
80
mM (15") C
OL
OR DIS
PL
AY
MA
XIM
UM B
OLL
AR
D H
EIG
HT I
N F
RO
NT
FIL
E N
O. 178-2
100 R
EV. 5