USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO
REGIME AT PALOMAR: LESSONS LEARNED
D. Mawet, R. Burruss, G. Serabyn,Jet Propulsion Lab - California Institute of Technology
5+ years effort:B. Mennesson, S. Bikkannavar, J. Crepp, E. Bloemhof, P. Haguenauer, J. Hickey, J.
Roberts, K. Rykoski, M. Troy, K. Wallace.
![Page 2: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/2.jpg)
Recipe for high contrast imaging from the groundHigh Strehl Ratio => Extreme AO
![Page 3: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/3.jpg)
Extreme AO
• Keep pupil location at DM
• Magnify pupil (by f1/f2)
• Center sub-pupil on DM
• Maintain F# to AO system ⇒ post-AO optics unchanged
Adaptive Optics Camera
Subaperture reimager
Existing TelescopeOptics:
DM
!
Result: >90% SR, best image quality ever on a ground-based telescope
![Page 4: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/4.jpg)
Recipe for high contrast imaging from the groundHigh Strehl Ratio => Extreme AO
Pointing stabilization => new SSM
✓
![Page 5: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/5.jpg)
New SSMSSM are responsible for pointing
accuracy and stability (≠ tip-tilt), which is the most fundamental requirement in
high contrast imaging:
- Old SSM had 20 mas accuracy, and intrinsic drifts.- New SSM have mas-level pointing accuracy and very little drift.- Are now commanded with feedback from the science image.
- Dynamic tip-tilt is fundamentally limited by the tip-tilt mirror inertia, but can be specifically addressed by fine tuning the tip-tilt loop gain in real time. !
![Page 6: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/6.jpg)
Recipe for high contrast imaging from the groundHigh Strehl Ratio => Extreme AO
Pointing stabilization => new SSM
Low-order aberration (focus) => pupil imaging
✓✓
![Page 7: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/7.jpg)
Fine focus tuning
Pupil imagingcapability
No control loop correction, one time fine tuning. Then relying on AO to keep it steady
![Page 8: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/8.jpg)
Recipe for high contrast imaging from the groundHigh Strehl Ratio => Extreme AO
Pointing stabilization => new SSM
Low-order aberration (focus) => pupil imaging
Quasi-static aberrations measurement and correction => Modified Gerchberg Saxton phase-retrieval
✓✓
✓
![Page 9: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/9.jpg)
Autonomous Phase Retrieval Calibration
Modified Gercherg-Saxton (MGS):
takes out-of-focus pairs of images with science camera (sense aberrations down to the final focal plane).
Off-line process (internal white light of the AO bench).
Performed for each new target.
![Page 10: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/10.jpg)
APRC
!
Best result: 11.71 nm rms within the DM bandwidth
![Page 11: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/11.jpg)
APRC limitationTurbulence on the AO bench itself !
APRC only senses and correct phase aberrations...
![Page 12: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/12.jpg)
Recipe for high contrast imaging from the groundHigh Strehl Ratio => Extreme AO
Pointing stabilization => new SSM
Low-order aberration (focus) => pupil imaging
Quasi-static aberrations measurement and correction => Modified Gerchberg Saxton phase-retrieval
Small Inner Working Angle Coronagraph => Vector Vortex Coronagraph
✓✓
✓
✓
![Page 13: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/13.jpg)
Vector Vortex CoronagraphPhase
“Phase screw disloca/on” at focal plane
€
eilθ
Intensity
Clears out the relayed pupil
FT
l = topological charge
from telescope
Coronagraph at focal plane Lyot stop detector
Selling points: small IWA (~1 λ/d), efficiency, clear 360º off-axis discovery space, rapid implementation
![Page 14: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/14.jpg)
Recipe for high contrast imaging from the ground
High Strehl Ratio => Extreme AO
Pointing stabilization => new SSM
Low-order aberration (focus) => pupil imaging
Quasi-static aberrations measurement and correction => Modified Gerchberg Saxton phase-retrieval
Small Inner Working Angle Coronagraph => Vector Vortex Coronagraph
Observing strategy oriented towards speckle calibration => RDI
✓✓
✓✓✓
![Page 15: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/15.jpg)
The good ol’ RDI with GOCI
![Page 16: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/16.jpg)
Observing strategy based on speckle decorrelation
1 ppm / min
Extreme AO on sky data !
![Page 17: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/17.jpg)
Strategy - RDI
MGS1-3 iter. Target Ref Target Ref ...
10-30 min ~ 10 min ~ 10 min ~ 10 min ~ 10 min
Reference chosen with: - same Vmag, K/H mag as the target.
- same dec, ΔRA ~ 10 min
<30 secMinimize overheads
What is the best on can do without a CAL system and(quasi)simultaneous differential imaging?
![Page 18: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/18.jpg)
Recipe for high contrast imaging from the ground
High Strehl Ratio => Extreme AO
Pointing stabilization => new SSM
Low-order aberration (focus) => pupil imaging
Quasi-static aberrations measurement and correction => Modified Gerchberg Saxton phase-retrieval
Small Inner Working Angle Coronagraph => Vector Vortex Coronagraph
Observing strategy oriented towards speckle calibration => RDI
Smart data reduction method => GOCI & LOCI
✓✓
✓✓
✓✓
![Page 19: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/19.jpg)
A few results
!
![Page 20: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/20.jpg)
Contrast analysis
!
![Page 21: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/21.jpg)
Recipe for high contrast imaging from the ground
High Strehl Ratio => Extreme AO
Pointing stabilization => new SSM
Low-order aberration (focus) => pupil imaging
Quasi-static aberrations measurement and correction => Modified Gerchberg Saxton phase-retrieval
Small Inner Working Angle Coronagraph => Vector Vortex Coronagraph
Observing strategy oriented towards speckle calibration => RDI
Smart data reduction method => LOCI
✓✓
✓✓
✓✓
✓
![Page 22: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/22.jpg)
FutureP3K - P1640 - Pharo/Vortex: finest ExAO system in the world (64x64 DM for a 5 m aperture), only one in the Northern hemisphere, best correction and largest outer working angle !
WCS at Keck (18 x 18 DM on a 3.6-meter off-axis portion of Keck)
!!
![Page 23: USING THE VECTOR VORTEX CORONAGRAPH IN THE EXAO …authors.library.caltech.edu/57862/1/Lyot2010proc_s8_talk... · 2015-05-27 · New SSM SSM are responsible for pointing accuracy](https://reader036.vdocuments.us/reader036/viewer/2022070703/5e77aca0964f7c77b05a36aa/html5/thumbnails/23.jpg)
Wanna know more about the vortex ? Come see my posters !