White Paper Abstract This white paper discusses how to configure SRDF/Metro on a VMware Metro Storage Cluster (vMSC) configured with an Oracle Applications environment running on Oracle Extended RAC. May 2016 VMAX Engineering USING SRDF/METRO IN A VMWARE METRO STORAGE CLUSTER RUNNING ORACLE E-BUSINESS SUITE AND 12C RAC DEMONSTRATING INTEROPERABILITY OF SRDF/METRO AND VMWARE, USING ORACLE APPLICATIONS RUNNING ON AN EXTENDED RAC CLUSTER

Upload: dinhhanh

Post on 05-Jun-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

White Paper

Abstract

This white paper discusses how to configure SRDF/Metro on a VMware Metro Storage Cluster (vMSC) configured with an Oracle Applications environment running on Oracle Extended RAC.

May 2016

VMAX Engineering

USING SRDF/METRO IN A VMWARE METRO STORAGE CLUSTER RUNNING ORACLE E-BUSINESS SUITE AND 12C RAC DEMONSTRATING INTEROPERABILITY OF SRDF/METRO AND VMWARE, USING ORACLE APPLICATIONS RUNNING ON AN EXTENDED RAC CLUSTER

Page 2: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Copyright © 2016 EMC Corporation. All Rights Reserved. EMC believes the information in this publication is accurate of its publication date. The information is subject to change without notice. The information in this publication is provided “as is.” EMC Corporation makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. VMware, ESXi, vMotion, and vSphere are registered trademarks or trademarks of VMware, Inc. in the United States and/or other jurisdictions. All other trademarks used herein are the property of their respective owners. Part Number h14577.2

2 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 3: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Table of Contents

Executive summary.................................................................................................. 5 Audience ............................................................................................................................ 5 Document scope and limitations ........................................................................................ 6

Introduction ............................................................................................................ 6

VMAX3 with HYPERMAX OS 5977 ............................................................................. 6

EMC Unisphere for VMAX ......................................................................................... 7

Fully Automated Storage Tiering (FAST) .................................................................... 8

SRDF/Metro ............................................................................................................. 9 Bias and Witness .............................................................................................................. 10 SRDF/Metro limitations .................................................................................................... 13

VAAI support ................................................................................................................ 14

VMware Metro Storage Cluster (vMSC) ................................................................... 15 VMware vMSC and SRDF/Metro ........................................................................................ 16 Uniform and Nonuniform vMSC ........................................................................................ 16 SRDF/Metro Witness in vMSC ........................................................................................... 17

SRDF/Metro and vMSC Failure Handling ....................................................................... 19

Setting up SRDF/Metro .......................................................................................... 20 SRDF group creation ......................................................................................................... 20 SRDF/Metro pair creation ................................................................................................. 24

Oracle Applications 12 .......................................................................................... 32 Applications Architecture ................................................................................................. 32 Working with FAST and Oracle Applications ...................................................................... 33

FAST elements .............................................................................................................. 34 Oracle Applications Tablespace Model ......................................................................... 35

Oracle Applications implementation ................................................................................. 36 Oracle Applications deployment ................................................................................... 36 Hardware layout ........................................................................................................... 38 FAST configuration for Oracle Applications ................................................................... 38

Oracle Real Application Clusters (RAC) on SRDF/Metro ........................................... 40 Extended RAC and Oracle Clusterware .............................................................................. 40 Oracle RAC and Oracle E-Business Suite ........................................................................... 41 Oracle Real Application Clusters (RAC) on VMFS ............................................................... 41

Oracle Clusterware deployment .................................................................................... 42 Oracle Extended RAC installation ...................................................................................... 42

3 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 4: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Procedure ..................................................................................................................... 42 Networking ................................................................................................................... 44

VMware Cluster Configuration with SRDF/Metro ..................................................... 45 vSphere HA ...................................................................................................................... 46

Heartbeating ................................................................................................................ 47 Polling time for datastore paths.................................................................................... 50

All Paths Down (APD) and Permanent Data Loss (PDL) ...................................................... 51 VMCP ........................................................................................................................... 51 PDL VMCP settings ....................................................................................................... 53 vMSC recommendations for PDL ................................................................................... 53 APD VMCP settings ....................................................................................................... 55 vMSC recommendations for APD .................................................................................. 57

VMware VM/Host Groups and VM/Host Rules .................................................................. 57 Best practices with VMware HA and SRDF/Metro .............................................................. 61

Viewing VMAX3 in vSphere .................................................................................... 62 EMC Virtual Storage Integrator .......................................................................................... 62

Conclusion ............................................................................................................ 64

References ............................................................................................................ 65 EMC .................................................................................................................................. 65 VMware ............................................................................................................................ 65 Oracle .............................................................................................................................. 66

Appendix A ........................................................................................................... 67 SRDF/Metro maintenance ................................................................................................. 67

Adding new pairs ......................................................................................................... 67 VM mobility ...................................................................................................................... 68

Appendix B – SRDF/Metro with VMware Site Recovery Manager .............................. 71 VMware vCenter Site Recovery Manager 6.1 ..................................................................... 72 Environment ..................................................................................................................... 72 Configuration ................................................................................................................... 75

SRDF SRA 6.1 ............................................................................................................... 75 Stretched Storage - Tags, Categories and Storage Policies ............................................ 77 Stretched Storage - Protection Group ............................................................................ 85 Stretched Storage - Recovery Plan ................................................................................ 88 Stretched Storage - Known Issue .................................................................................. 90 Cross-vMotion - Known Limitation ................................................................................ 91

SRDF Adapter Utilities 6.1 ................................................................................................. 91

4 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 5: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Executive summary The EMC® VMAX™ family provides disaster recovery and mobility solutions through its remote replication technology SRDF® (Symmetrix Remote Data Facility). SRDF has the capability to replicate between multiple sites, co-located or even thousands of miles apart depending on the type of replication desired.

Beginning with HYPERMAX OS 5977 Q3 2015 Service Release and Solutions Enabler and Unisphere for VMAX 8.1, EMC offers SRDF/Metro®, an active/active version of SRDF. In a traditional SRDF device pair relationship, the secondary device, or R2, is write disabled. Only the primary device, or R1, is accessible for read/write activity. With SRDF/Metro the R2 is also write enabled and accessible by the host or application. The R2 takes on the personality of the R1 including the WWN. A host, therefore, would see both the R1 and R2 as the same device.

As both devices are simultaneously accessible, the hosts in a cluster, for example, can read and write to both the R1 and R2. The SRDF/Metro technology ensures that the R1 and R2 remain current and consistent, addressing any conflicts which might arise between the pairs.

When SRDF/Metro is used in conjunction with VMware vSphere® across multiple hosts, a VMware Metro Storage Cluster (vMSC) is formed. At its core, a VMware vMSC infrastructure is a stretched cluster. The architecture is built on the idea of extending what is defined as “local” in terms of network and storage. This enables these subsystems to span geographies, presenting a single and common base infrastructure set of resources to the vSphere cluster at both sites. In essence, it stretches network and storage between sites.

With vMSC customers acquire the capability to migrate virtual machines between sites with VMware vSphere vMotion® and vSphere Storage vMotion, enabling on-demand and nonintrusive mobility of workload.

Combining these technologies together with an enterprise ERP and CRM software solution like Oracle Applications running on Oracle Extended RAC, provides a highly available enterprise solution.

Audience

This white paper is intended for VMware administrators, Oracle DBAs, server administrators, and storage administrators responsible for creating, managing, and using VMware, as well as their underlying storage devices, for their VMware vSphere environments attached to a VMAX3 storage array running HYPERMAX OS 5977 and SRDF/Metro. The white paper assumes the reader is familiar with Oracle databases and applications, VMware environments, VMAX3 and the related software.

5 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 6: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Document scope and limitations

This document applies to EMC SRDF/Metro configured with a Witness, VMware vSphere and Oracle Applications on Oracle Extended RAC. The details provided in this white paper are based on the following software and hardware:

• EMC SRDF/Metro with HYPERMAX OS 5977.691.684 plus the ePack for ESXi support

• 2 VMAX3 arrays that are part of the SRDF/Metro cluster are within 5 milliseconds (ms) of each other to allow for VMware HA

• SRDF/Metro Witness is deployed to a third VMAX3 array also in metro distance

• Solutions Enabler/Unisphere for VMAX 8.1

• vSphere 6.0 U1 (vCenter, ESXi) using NMP

• EMC VSI 6.7

• Oracle Applications Release 12

• Oracle RAC 12c

Introduction The purpose of this paper is not to present performance results or scalability tests of the various products included, but rather to lay out how these different technologies can be integrated and will work together to provide a robust High Availability solution.

This document, therefore, will present the best practices for the various components involved in the solution. Even were this lab environment to adhere perfectly to the physical requirements, it may not replicate a particular customer’s environment. By including the best practices, however, a customer can use the information and the resources at hand to design the best possible environment for their needs.

The details around setting up the physical hardware will only be mentioned as necessary to the solution, e.g. sufficient disk technologies to meet SLOs. Customers are advised to work with EMC to ensure their physical hardware for VMAX3 is properly setup and configured to take advantage of solutions such as the one presented in this white paper.

The following sections provide a brief introduction to the EMC technologies most involved in this solution: VMAX3, Unisphere for VMAX, and FAST.

VMAX3 with HYPERMAX OS 5977 The VMAX3 Family 100K, 200K, 400K arrays provide unprecedented performance and scale. Ranging from the single or dual-engine VMAX 100K up to the eight engine VMAX 400K, these new arrays offer dramatic increases in floor tile density with

6 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 7: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

engines and high capacity disk enclosures for both 2.5" and 3.5" drives consolidated in the same system bay.

The VMAX3 arrays support the use of native 6 Gb/s SAS 2.5” drives, 3.5” drives, or a mix of both drive types. Individual system bays can house either one or two engines and up to six high-density disk array enclosures (DAEs) per engine available in either 3.5” (60 slot) or 2.5" (120 slot) formats. Each system bay can support up to 720 2.5" drives or 360 3.5" drives, or a mix of the two.

The Dynamic Virtual Matrix architecture allows scaling of system resources through common and fully redundant building blocks called VMAX3 engines. VMAX3 engines provide the complete foundation for high-availability storage arrays.

The VMAX3 utilizes Virtual Provisioning (VP), a type of host-accessible device called a thin device, or virtual device, which can be used in many of the same ways that regular, host-accessible VMAX devices have traditionally been used. VP offers storage efficiency/flexibility that traditional thick volumes cannot. Unlike thick devices, thin devices do not need to have physical storage completely allocated at the time the devices are created and presented to a host. The physical storage that is used to supply drive space for a thin device comes from a shared Storage Resource Pool, or SRP. An SRP is comprised of data pools which in turn are made up of internal VMAX3 devices called data devices.

The VMAX3 arrays come fully pre-configured out of the factory to significantly shorten the time to first I/O during installation.

EMC Unisphere for VMAX EMC Unisphere™ for VMAX (Unisphere) is EMC’s VMAX array management software which offers big-button navigation and streamlined operations to simplify and reduce the time required to manage a data center. Unisphere for VMAX simplifies storage management under a common framework, incorporating Symmetrix Performance Analyzer which previously required a separate interface.

In addition, with the Performance monitoring option, Unisphere for VMAX provides tools for performing analysis and historical trending of VMAX system performance data.

The default Storage Groups Dashboard is presented in Figure 1.

7 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 8: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 1. Unisphere for VMAX – Default Storage Groups Dashboard

Unisphere for VMAX, shown in the preceding figure, can be run on a number of different kinds of open systems hosts, physical or virtual. Unisphere for VMAX is also available as a virtual appliance for ESXi in VMware vSphere and as an embedded guest OS on the VMAX3 array. For more details please visit support.EMC.com.

Fully Automated Storage Tiering (FAST) EMC Fully Automated Storage Tiering (FAST) provides automated management of VMAX3 array disk resources on behalf of thin devices. FAST automatically configures disk groups to form a Storage Resource Pool (SRP) by creating thin pools according to each individual disk technology, capacity and RAID type. FAST technology moves the most active parts of your workloads (hot data) to high-performance flash disks and the least-frequently accessed storage (cold data) to lower-cost drives, leveraging the best performance and cost characteristics of each different drive type. FAST delivers higher performance using fewer drives to help reduce acquisition, power, cooling, and footprint costs. FAST is able to factor in the RAID protections to ensure write heavy workloads go to RAID 1 and read heavy workloads go to RAID 6. This process is entirely automated and requires no user intervention.

8 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 9: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

SRDF/Metro SRDF/Metro is a new feature available on the VMAX3 which provides active/active access to the R1 and R2 of an SRDF configuration. In traditional SRDF, R1 devices are Read/Write accessible while R2 devices are Read Only/ Write Disabled. In SRDF/Metro configurations both the R1 and R2 are Read/Write accessible. The way this is accomplished is the R2 takes on the personality of the R1 in terms of geometry and most importantly the WWN. By sharing a WWN, the R1 and R2 appear as a shared virtual device across the two VMAX3 arrays for host presentation. A host or typically multiple hosts in a cluster can read and write to both the R1 and R2. SRDF/Metro ensures that the each copy remains current and consistent and addresses any write conflicts which might arise. A simple diagram of the feature is available in Figure 2.

Figure 2. SRDF/Metro

SRDF/Metro is supported on VMAX3 arrays running HYPERMAX OS 5977 Q3 2015 SR1 or higher. This feature provides the following advantages:

• A high availability solution at Metro distances by leveraging and extending SRDF/S functionality.

• Active-Active replication capabilities on both the source and target sites.

• Witness support to enable full high availability, resiliency, and seamless failover.2

1 See E-Lab™ for the currently supported hosts and multi-pathing software. The E-Lab Interoperability Navigator can be found at this address: https://elabnavigator.emc.com. 2 The SRDF SRA only supports the use of Bias with VMware SRM.

9 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 10: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Bias and Witness

SRDF/Metro maintains consistency between the R1 and R2 during normal operation. If, however, a device or devices go not ready (NR) or connectivity is lost between the arrays, SRDF/Metro selects one side of the environment as the “winner” and makes the other side inaccessible to the host(s). There are two ways that SRDF/Metro can determine a winner: bias or SRDF/Metro Witness (Witness). The bias or Witness prevents any data inconsistencies which might result from the two arrays being unable to communicate.

Bias is a required component of SRDF/Metro, with or without Witness. Witness builds upon the bias functionality – in essence bias becomes the failsafe in case Witness is unavailable or fails. The initial createpair operation of SRDF/Metro will assign bias to the R1 site though it is possible to change it to the R2 after initial synchronization. Note changing the bias turns the R2 into the R1. In the event of a failure, SRDF/Metro makes the non-biased side inaccessible to the host(s) while the bias side (R1) survives. Bias is denoted by the state of “ActiveBias” on a device pair or SRDF group as in Figure 3. Note the Bias Location is “Local”, meaning this is the R1 side.

Figure 3. ActiveBias state for SRDF/Metro

If the bias side (R1) experiences the failure, then the entire SRDF/Metro cluster becomes unavailable to the hosts and will require user intervention to rectify. To avoid these types of failures, EMC offers the Witness. The Witness is an external arbiter running on a separate VMAX or VMAX3 with the proper code. A separate SRDF group is created from each SRDF/Metro array (R1, R2) to the Witness array and marked as witness or quorum groups. The use of the Witness supersedes the bias functionality. If the SRDF groups to the Witness are present before the createpair command is executed, the device pair(s) will automatically enter a “Witness Protected” state upon synchronization and the state will be “ActiveActive.” The ActiveActive state for SRDF/Metro can be seen in Unisphere in Figure 4.

10 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 11: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 4. ActiveActive state for SRDF/Metro

Alternatively if the groups are added after synchronization, at the next re-establish the Witness will take effect. It is also possible to configure multiple Witnesses if multiple arrays are available. In such cases the SRDF/Metro handles the use of multiple Witnesses so if the initial one fails, no user intervention is required to enable a secondary one.

The following screenshot in Figure 5 obtained from Solutions Enabler, provides an example of a failure of the Witness. Note that for the SRDF group the configured type(C) is Witness, but the effective type(E) is Bias. This is due to the Witness status(S) being Failed.

11 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 12: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 5. An SRDF/Metro group with a failed Witness

Once the issue with the Witness is resolved, the group automatically is returned to an effective Witness state and a Normal status as in Figure 6.

12 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 13: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 6. Restoring the Witness

As this whitepaper will not detail all failure scenarios of an SRDF/Metro configuration, please see the References section for the Technical Note EMC VMAX3 SRDF/Metro Overview and Best Practices if more information is desired.

SRDF/Metro limitations

As SRDF/Metro (active mode) is a different type of SRDF implementation, there are some restrictions which do not exist for other SRDF modes. As such they are included here for reference. Note that this list is based on HYPERMAX OS 5977 Q1 2016 SR release of SRDF/Metro. Many restrictions will be lifted in future releases.

• Both the source (R1) and target (R2) arrays must be running HYPERMAX OS 5977 Q3 2015 SR or higher.

• Existing SRDF device pairs that participate in an SRDF mode of operation cannot be part of an SRDF/Metro configuration; SRDF device pairs that participate in an SRDF/Metro configuration cannot participate in any other SRDF mode of operation.

• Concurrent or Cascaded SRDF devices are not supported.

• The R1 and R2 must be the same size.

• Devices cannot have Geometry Compatibility Mode (GCM) set.

13 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 14: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

• Devices cannot have User Geometry set.

• Controlling devices in an SRDF group that contain a mixture of source (R1) and target (R2) devices is not supported.

• The following operations must apply to all devices in the SRDF group: createpair –establish, establish, restore, and suspend

Note that SRDF/Metro supports all of the vSphere Storage APIs for Array Integration (VAAI) commands save for Full Copy (XCOPY).

VAAI support

As noted above, SRDF/Metro does not support the VAAI primitive, XCOPY. However as support is disabled in the code, VMware will report that the primitive is supported. In the vSphere Web Client VAAI support is represented only as a single capability called “Hardware Acceleration.” Figure 7 is the datastore and SRDF/Metro device, DATA_1, which reports support for VAAI.

Figure 7. Checking VAAI support in the vSphere Client

The CLI, on the other hand, details the status for each of the 4 primitives for the same device backing datastore DATA_1. In Figure 8 note that Clone Status (XCOPY) shows as supported.

14 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 15: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 8. Checking VAAI support in the CLI

So though VMware will still issue the commands if required, they will not be accepted for SRDF/Metro devices. As with all VAAI integration, however, the user is not required to make any changes and therefore the fact that XCOPY is supported will not be readily apparent to the end user.

VMware Metro Storage Cluster (vMSC) A VMware vSphere Metro Storage Cluster configuration is a VMware vSphere 5 or 6 certified solution that combines synchronous replication with array-based clustering. These solutions typically are deployed in environments where the distance between datacenters is limited, often metropolitan or campus environments. EMC SRDF/Metro represents one of those certified solutions.

A VMware vMSC requires what is in effect a single storage subsystem that spans both sites. In this design, a given datastore must be accessible (able to be read and written to) simultaneously from both sites. Furthermore, when problems occur, the ESXi hosts must be able to continue to access datastores from either array, transparently and without impact to ongoing storage operations.

The storage subsystem for a VMware vMSC must be able to be read from and write to the two locations simultaneously. All disk writes are committed synchronously at the two locations to ensure that data is always consistent regardless of the location from which it is being read. This storage architecture requires significant bandwidth and very low latency between the sites involved in the cluster. Increased distances or latencies cause delays writing to disk, making performance suffer dramatically, and prevent vMotion activities between the cluster nodes that reside in different locations.

VMware (and therefore SRDF/Metro on VMware) supports 32 hosts in a cluster in vSphere 5 and 64 hosts in a cluster in vSphere 6.

15 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 16: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

VMware vMSC and SRDF/Metro

EMC SRDF/Metro breaks physical barriers of data centers and allows users to access data at different geographical locations concurrently. This functionality in a VMware context enables functionality that was not available previously. Specifically, the ability to concurrently access the same set of devices independent of the physical location enables geographically stretched clusters based on VMware vSphere – in other words vMSC. This allows for transparent load sharing between multiple sites while providing the flexibility of migrating workloads between sites in anticipation of planned events such as hardware maintenance. Furthermore, in case of an unplanned event that causes disruption of services at one of the data centers, the failed services can be quickly and easily restarted at the surviving site with minimal effort. Nevertheless, the design of the VMware environment has to account for a number of potential failure scenarios and mitigate the risk for services disruption.

Uniform and Nonuniform vMSC

There are two types of configurations available for vMSC: uniform and nonuniform (Figure 9). VMware defines them as such:

• Uniform host access configuration – When ESXi hosts from both sites are all connected to a storage node in the storage cluster across all sites. Paths presented to ESXi hosts are stretched across distance.

• Nonuniform host access configuration – ESXi hosts in each site are connected only to storage node(s) in the same site. Paths presented to ESXi hosts from storage nodes are limited to the local site.

The environment detailed in this paper is a nonuniform configuration for vMSC with SRDF/Metro so each host only sees its respective VMAX3 array. EMC also supports using a uniform (also known as cross-connect) configuration.3 SRDF/Metro maintains the cache state on each array, so an ESXi host in either datacenter detects the “virtual” device as local. Even when two virtual machines reside on the same datastore but are located in different datacenters, they write locally without any performance impact on either of them. Each host accesses and is served by its own array with SRDF/Metro ensuring consistency. If a Witness is not in use, there is site bias, meaning that one site will be the winner in the event of failure.

3 EMC supports uniform configurations with an RPQ. If using uniform with RR PSP it is essential to leave the IOPS setting at the default of 1000.

16 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 17: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 9. vMSC nonuniform configuration with SRDF/Metro

SRDF/Metro Witness in vMSC

As noted in the previous paragraph, SRDF/Metro by default uses site bias to define how a site or link failure should be handled in a SRDF/Metro configuration. If two clusters lose contact, the bias defines which cluster continues operation and which suspends I/O. Bias is defined at the SRDF group level. The use of bias to control which site is a winner, however, adds unnecessary complexity in case of a site failure since it may be necessary to manually intervene to resume I/O to the surviving site. SRDF/Metro has the capability to use a Witness, instead of bias. The SRDF/Metro Witness is available through a third VMAX or VMAX3 array4. The VMAX can reside in a physically separate failure domain to either VMAX3 arrays in the metro configuration if desired.

It provides the following features:

• Active/active use of both data centers

4 See SRDF/Metro product documentation for the exact Enginuity or HYPERMAX OS supported versions.

17 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 18: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

• High availability for applications (no single points of storage failure, auto-restart)

• Fully automatic failure handling

• Better resource utilization

• Lower capital expenditures and lower operational expenditures as a result

Note: Fault domain is decided by the customer and can range from different racks in the same datacenter all the way up to a 5ms of distance away from each SRDF/Metro cluster (5ms measured latency or typical synchronous distance).

A configuration that uses SRDF/Metro with Witness allows both sides to provide coherent read/write access to the same virtual volume. That means that on the remote site, the paths are up and the storage is available even before any failover happens. When this is combined with host failover clustering technologies such as VMware HA, one gets a fully automatic application restart for any site-level disaster. The system rides through component failures within a site, including the failure of an entire array.

In this scenario, a virtual machine can write to the same virtual device from either cluster. In other words, if the customer is using VMware Distributed Resource Scheduler (DRS), which allows the automatic load distribution on virtual machines across multiple ESXi servers, a virtual machine can be moved from an ESXi server attached to the R1 array to an ESXi server attached to R2 array without losing access to the underlying storage. This configuration allows virtual machines to move between two geographically disparate locations with up to 5 ms of latency, the limit to which VMware vMotion is supported.

In the event of a complete site failure, shown in Figure 10, SRDF/Metro Witness automatically assigns the R2 array as the winner, rather than following the R1 site bias. VMware HA detects the failure of the virtual machines and restarts the virtual machines automatically at the surviving site with no user intervention.

18 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 19: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 10. vMSC with SRDF/Metro Witness

SRDF/Metro and vMSC Failure Handling

There are EMC and VMware documents available that cover all the various failure scenarios that can impact a SRDF/Metro and vMSC environment. As this paper is not specifically addressing those scenarios, they are included in the References section so the customer may review them before deployment.

19 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 20: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Setting up SRDF/Metro SRDF/Metro can be configured with Solutions Enabler (CLI) or with Unisphere for VMAX. EMC recommends using Unisphere to configure SRDF/Metro to reduce complexity. This section details the setup and includes those tasks directly related to SRDF/Metro setup. In this example, the following objects are assumed to already exist as their creation is independent of SRDF/Metro:

• Initiator groups for each site

• Port groups for each site

• Devices on each site created and placed in a single storage group on each array

• A masking view exists for the R1 array, but NOT for the R2

SRDF group creation

SRDF/Metro is a feature of SRDF and therefore the same basic process is followed when setting up device pairs. Initially, an SRDF group is required on each VMAX3 array. Within Unisphere for VMAX navigate to array -> Data Protection -> Replication Groups and Pools -> SRDF Groups as in Figure 11.

Figure 11. SRDF group creation in Unisphere for VMAX

Enter the required information, and select OK to save as in Figure 12. This will create an SRDF group on each array. Be sure not to check the box labeled “SRDF/Metro Quorum Group” as that refers to the Witness which will be covered next. Therefore

20 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 21: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

note that there is no distinction between a Metro group and an SRDF group for another mode such as async.

Figure 12. SRDF group creation for Metro

In the environment detailed in this whitepaper, a Witness is being utilized. SRDF/Metro defaults to the bias option unless there is another SRDF group on a third site (VMAX or VMAX3 array) to which each Metro array is configured. In such cases, when creating device pairs in the group, the witness option will be specified which will supersede the bias, though it remains as part of the configuration in case the Witness fails.

Create a group from each Metro array to the third Witness array, which is demonstrated in Figure 13 and Figure 14. A Witness group is designated by checking the box “SRDF/Metro Quorum Group.”

If a Witness group already exists to the remote array, the setting for SRDF/Metro Quorum Group will be grayed-out.

21 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 22: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 13. Creating the SRDF group from R1 to Witness array in Unisphere

22 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 23: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 14. Creating the SRDF group from R2 to Witness array in Unisphere

To add an SRDF group for the Witness using Solutions Enabler, specify the “–witness” flag to a standard SRDF group creation statement shown in Figure 15.

23 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 24: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 15. Creating SRDF groups for the Witness through CLI

If a Witness group already exists, whether or not it is in use, Solutions Enabler will return the following error: A Witness RDF group already exists between the two Symmetrix arrays.

SRDF/Metro pair creation

The Protection Dashboard in Unisphere provides an easy-to-use wizard to enable SRDF/Metro on a storage group. Before starting the wizard, it is important to remember that though this is an active-active device configuration, the R2 should NOT be presented to the hosts until all devices are fully synchronized.

Start by navigation to the Protection Dashboard seen in Figure 16 and selecting “Total” in step 1 to see all the storage groups available for protection.

24 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 25: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 16. Protection Dashboard in Unisphere

In step 2, Figure 17, highlight the desired storage group for protection and select the button “Protect” at the bottom of the screen.

Figure 17. Storage group selection for SRDF/Metro setup

25 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 26: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

With the storage group selected, Unisphere provides the available protection types on the array. Select “High Availability Using SRDF/Metro” radio button and then “Next.” This step is shown in Figure 18.

Figure 18. Protection Type in protection wizard

In step 4, Figure 19, Unisphere will select “Auto” for the SRDF Group. As the groups were created in a previous step, in this example the SRDF Group is changed to “Manual” and the correct selection made. Similarly the remote storage group name will be automatically generated, though it can be altered as in this case. Note, too that if a Witness group exists, Unisphere will select “Quorum” but it can be overridden to “Bias” if so desired.

26 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 27: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 19. SRDF/Metro Connectivity in in protection wizard

Finally review the proposed changes in step 5 in Figure 20 and run the task.

27 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 28: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 20. Complete protection wizard

Once completed, the SRDF/Metro dashboard in Figure 21 will show the group syncing.

Figure 21. SRDF/Metro dashboard

The user should wait until the State in Figure 21 reads “ActiveActive” before creating a masking view for the R2 devices. That will mean the synchronization is complete. Alternatively if using bias, the synchronized state is “ActiveBias.” Solutions Enabler may also be used to verify the state of the RDF group (Figure 22).

28 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 29: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 22. Verify SRDF/Metro state in CLI

Once the state is in the proper active state, the R2 devices can be presented to the R2 host(s) using the masking view wizard in Unisphere, displayed in Figure 23.

29 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 30: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 23. Create R2 masking view

As shown above, when setting up SRDF/Metro pairs, Unisphere for VMAX wizards work at the storage group level. If the devices are not already in a storage group, Unisphere can still be utilized in more of a manual fashion. For instance, pairs can be created in the “Replication Groups and Pools” screen in the Data Protection area of

30 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 31: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Unisphere. Here use the SRDF Mode “Active” to denote SRDF/Metro pairs. The ability to set a Witness and add devices to storage groups is available and seen in Figure 24.

Figure 24. Creating SRDF/Metro pairs in Unisphere without a storage group

In Unisphere, any storage groups in an SRDF/Metro relationship will appear in the High Availability protection group that is part of the Protection Dashboard. Figure 25 shows the R2 side of the SRDF/Metro group created in this section.

31 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 32: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 25. Unisphere Protection Dashboard - High Availability

Though EMC recommends using Unisphere, it is possible to setup SRDF/Metro using Solutions Enabler. In general, setting up SRDF/Metro is akin to any SRDF configuration, save for during the createpair command when the switch –rdf_metro should be specified for an SRDF/Metro pair.

Oracle Applications 12 Oracle Applications, or Oracle E-Business Suite, is a tightly integrated family of Financial, ERP, CRM, and manufacturing application products that share a common look and feel. Using the menus and windows of Oracle Applications, users have access to all the functions they need to manage their business information. Oracle Applications is highly responsive to users, supporting a multi-window GUI that provides users with full point-and-click capability. In addition, Oracle Applications offers many other features such as field-to-field validation and a list of values to help users simplify data entry and maintain the integrity of the data they enter.

Applications Architecture

The Oracle Applications Architecture is a framework for multi-tiered, distributed computing that supports Oracle Applications products. In this model, various servers or services are distributed among three levels, or tiers.

A tier is a logical grouping of services, potentially spread across more than one physical or virtual machine. The three-tier architecture that comprises an Oracle E-Business Suite installation is made up of the database tier, which supports and manages the Oracle database; the application tier, which supports and manages the

32 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 33: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

various Applications components, and is sometimes known as the middle tier; and the desktop tier, which provides the user interface through an add-on component to a standard web browser.

The simplest architecture for Oracle Applications is to have all tiers, except the desktop tier, installed on a single server. This configuration might be acceptable in a development environment, but for production environments scaling would quickly become an issue. In order to mimic a more realistic production environment, therefore, the architecture of the testing environment is built with two physical application tiers and two database tiers. The architectural components of Oracle Applications are seen in Figure 26.

Figure 26. Oracle Applications architecture

Working with FAST and Oracle Applications

Because of the diversity of Oracle Applications, in that there are hundreds of different modules within a single product, deploying them appropriately on the right tier of storage is a daunting task. Implementing them in a VMware environment that utilizes

33 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 34: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

VMAX3 with FAST technology will enable how a customer can achieve proper performance and cost savings at the same time.

FAST provides the ability to deliver variable performance levels through Service Level Objectives (SLO). Thin devices can be added to a storage group and the storage group can be assigned a specific Service Level Objective to set performance expectations. FAST monitors the storage group’s performance relative to the Service Level Objective and automatically and non-disruptively relocates data to maintain a consistent performance level.

FAST runs entirely within HYPERMAX OS, the storage operating environment that controls components within the array.

FAST elements

There are five main elements that comprise FAST on VMAX3 arrays. These are graphically depicted in Figure 27. These are:

• Disk groups

• Data pools

• Storage Resource Pools (SRP)

• Service Level Objectives (SLO)

• Storage groups

Figure 27. FAST elements

• SLO — defines an expected average response time target for an application.

34 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 35: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

• Storage group — a logical collection of VMAX3 devices that are to be managed together, and may constitute a single application. Storage group definitions are to be shared between FAST and auto-provisioning groups.

• SRP — a collection of data pools constituting a FAST domain.

• Data pool — a collection of data devices of identical emulation and protection type, all of which reside on disks of the same technology type and speed. The disks in a data pool are from the same disk group.

• Disk group— a collection of physical drives within the array that share the same performance characteristics, which are determined by rotational speed (15K, 10K, and 7.2K), technology (SAS, flash SAS), and capacity.

Storage groups can be created, managed and assigned an SLO by using either Unisphere or the Solutions Enabler Command Line Interface (SYMCLI). The other FAST elements, including the available SLOs, are factory configured and cannot be modified by the user.

FAST manages the allocation of new data within the SRP by automatically selecting a SRP based on available disk technology, capacity and RAID type. If a storage group has a SLO, FAST automatically changes the ranking of the SRPs used for initial allocation. If the preferred drive technology is not available, allocation reverts to the default behavior and uses any available SRP for allocation.

FAST enforces SLO compliance within the SRP by restricting the available technology allocations. For example, the Platinum SLO cannot have allocations on 7K RPM disks within the SRP. This allows FAST to be more reactive to SLO changes and ensure critical workloads are isolated from lower performance disks.

Note: For more information on FAST and SLOs see EMC VMAX3 Service Level Provisioning with Fully Automated Storage Tiering (FAST) on support.EMC.com.

Oracle Applications Tablespace Model

For this paper, the latest Oracle Applications release 12 was installed and configured. There are a few benefits to using the latest release but most importantly, unlike previous Oracle Application releases, Oracle no longer uses two tablespaces, and hence at least two datafiles, per application. Prior to release 12, each Applications module had its own set of tablespaces and datafiles, one for the data and one for the index. With over 200 schemas, managing a database of over 400 tablespaces and datafiles was, and is, a sizable undertaking. The new approach that Oracle uses in release 12 is called the Oracle Applications Tablespace Model, or OATM.

OATM is similar to the traditional model in retaining the system, undo, and temporary tablespaces. The key difference is that Applications products in an OATM environment share a much smaller number of tablespaces, rather than having their own dedicated tablespaces.

Applications schema objects are allocated to the shared tablespaces based on two main factors: the type of data they contain, and I/O characteristics such as size, life

35 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 36: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

span, access methods, and locking granularity. For example, tables that contain seed data are allocated to a different tablespace from the tables that contain transactional data. In addition, while most indexes are held in the same tablespace as the base table, indexes on transaction tables are held in a single tablespace dedicated to such indexes.

As will be explained, OATM is a perfect match for the FAST technology because despite the data being consolidated into less datafiles, FAST is able to separate it on the backend based on how it is accessed.

Oracle Applications implementation

A customer implementation of Oracle Applications is not a quick process. The installation itself is only the first part of what can be an endeavor lasting many months or longer. Although there are almost 200 application modules in the Oracle Applications, customers rarely, if ever, use all of them. They use a selection of them, or perhaps a bundle such as Financials, or CRM. These modules are then implemented (typically) in a phased approach. The transition from an existing applications system or implementation of a new system takes time. How that system eventually will be used, and more importantly how that database will be accessed, presents a real challenge for the system administrator and database administrator. These individuals are tasked with providing the right performance for the right application at the right price. In other words, both performance optimization and cost optimization are extremely important to them; however, obtaining the balance between the two is not an easy task. This is made even more difficult under the new Oracle Applications Tablespace Model. Oracle’s new model certainly does a good job at high-level database object consolidation – less tablespaces and less datafiles – but since the application modules are no longer separated into individual tablespaces and datafiles, there really is no practical way to put different modules on different tiers of storage – until now. FAST is the perfect complement to the manner in which Oracle implements the database in release 12 of the Oracle application suite. In fact, the entire database of user data can be placed on a single mount point on a VMware virtual disk and yet still be spread over the appropriate disk technologies that match the business requirements. The simplicity of this deployment model is enabled by FAST and Service Level Objectives.

Oracle Applications deployment

The Oracle Applications’ VMware environment deployed in this study consists of two ESXi 6.0 U1 servers with a total of five virtual machines listed in Table 1. The environment is managed by a VMware vCenter Server. Figure 28 is a high-level visual representation of the environment. Note not all hardware components are included.

36 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 37: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Table 1. Example environment

Virtual Machine Name Model OS & Version

CPUs RAM (GB)

Disk

RAC Database Tier Node 1

dsib2233 VMware VM

OEL 6.7 64-bit

4 16 SAN

RAC Database Tier Node 2

dsib2234 VMware VM

OEL 6.7 64-bit

4 16 SAN

Applications Tier 1 dsib0242 VMware VM

OEL 6.7 64-bit

4 12 SAN

Applications Tier 2 dsib0243 VMware VM

OEL 6.7 64-bit

4 12 SAN

Production vCenter dsib2113 VMware VM

Win2008 64-bit

2 12 SAN

EMC VMAX3 HK000196700535 VMAX 200K

5977.691.684 microcode R1 SATA,FC,

EFD

EMC VMAX3 HK000196700536 VMAX 200K

5977.691.684 microcode R2 SATA,FC,

EFD EMC VMAX3 HK000197200056 VMAX

400K 5977.691.684

microcode Witness SATA,FC,EFD

37 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 38: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Hardware layout

Figure 28. Physical/virtual environment diagram

FAST configuration for Oracle Applications

In each VMAX3 array there are 3 disk technologies: EFD, FC, and SATA. The disks are automatically configured in the factory into disk groups and then thin pools. The disks together comprise a Storage Resource Pool:

• Group 1: FC – RAID 1

• Group 2: SATA – RAID-6 (6+2)

• Group 3: EFD – RAID-5 3+1

The screen capture in Figure 29 shows the content of the Storage Resource Pool.

38 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 39: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 29. Disk group configuration for the SRP

The 3 disk technologies enable the use of all the SLOs seen in Figure 30.

Figure 30. Service Level Objectives

Because of the varied workloads that an Oracle Applications environment may experience, from order entry to running reports, the assigned SLO is Optimized. Optimized SLO offers an optimal balance of resources and performance across the whole SRP, based on I/O load, type of I/O, data pool utilization, and available

39 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 40: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

capacities in the pools. It will place the most active data on higher performing storage and least active data on the most cost-effective storage. If data pools’ capacity or utilization is stressed it will attempt to alleviate it by using other pools.

FAST and SRDF/Metro

FAST shares performance statistics across the arrays in a typical active/passive SRDF configuration to ensure the workload is properly represented on the remote site (R2) in case of failover. This statistic sharing has been extended to an SRDF/Metro configuration, with both the R1 and R2 sending statistics across to the other array. This sharing is particularly important since the R1 and R2 are both in an active state and users accessing the same application may be balanced across hosts on each side of the cluster. The sharing ensures that the whole workload (R1+R2) is represented.

The sharing of statistics has no bearing on the SLO selection for storage groups that are participating in an SRDF relationship. Even in an SRDF/Metro configuration, the R1 and R2 devices can be in different SLOs.

While it is possible to have a different SLO for each site in an SRDF/Metro configuration, as the Oracle Applications are balanced across both application and database nodes, and thus sites, it is recommended that both storage groups have the same SLO of Optimized. This will ensure a balanced performance experience whether the user is executing I/O against the R1 or R2.

Oracle Real Application Clusters (RAC) on SRDF/Metro Oracle deployments on virtual hardware should essentially be no different than physical hardware. In other words you can achieve all the scaling benefits of the hypervisor without being concerned that Oracle will run differently than when run on a physical host. Like its physical host counterpart virtual deployments should follow best practices for Oracle databases. Other recommendations mirror physical deployments and can be found at the VMware website. The References section includes some of these documents.

Extended RAC and Oracle Clusterware

Oracle Extended RAC is a deployment model for Oracle Real Application Clusters in which the server nodes reside in physical separate locations. Such a deployment has strict software and hardware requirements but can be enabled with such advanced technologies as SRDF/Metro. Extended RAC maintains the strict latency requirements and disk sharing. Such a deployment is typically in a metro or campus environment. SRDF/Metro provides the perfect solution for Extended RAC and is fully supported by Oracle.

One of the benefits of SRDF/Metro is the avoidance of a third site for the Oracle voting disks which is usually a requirement of Extended RAC. A third site prevents a split-brain situation where the Oracle nodes are unaware there has been an interconnect

40 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 41: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

issue and both sides continue to receive I/O. A SRDF/Metro does not need the third site because it uses a Witness in a third site fault domain as discussed previously in this paper. The behavior of Extended RAC with an SRDF/Metro Witness is as follows:

• If there is an interconnect failure between Oracle RAC nodes that is unrelated to SRDF, Oracle Clusterware will reconfigure based on majority rules and access to the voting disk.

• If there is an SRDF link failure or a site failure, SRDF will initiate bias preference rules with witness guidance and continue I/O at the designated site. The Oracle RAC node(s) accessing storage at the surviving SRDF/Metro site will still have access to the voting disks and therefore Oracle Clusterware will reconfigure the cluster in accordance with this.

Oracle RAC and Oracle E-Business Suite

The Oracle E-Business Suite implementation (default demo database VIS) used in this paper installs as a single instance on a single node. If the user desires to use RAC, he must convert the database from single to multiple instances. For standalone databases, this is not a trivial task but for E-Business Suite environments it is even more complicated. Oracle provides a number of support notes to guide the user through the implementation. There are two components involved – the applications and the database. Because Oracle Applications is integrally tied to the database, it requires an upgrade just like the database. There are numerous patches and configuration changes that must be completed before the database can be moved to RAC. The Oracle notes are extensive and detailed and version specific for the applications and the database. They are also frequently updated with new information. It is therefore impossible to properly explain the process used in this environment beyond the high-level one already mentioned. The support notes used in this upgrade are included in the References for the user’s reference.

The focus here will be on one possible upgrade path to RAC in an Oracle E-Business Suite Environment. Oracle provides for the conversion to RAC on a number of different paths. The one used in this paper was a separate install of the 12.1.0.2 binaries (grid and database), a conversion to ASM, and an upgrade of the applications database both to the new database version and to Extended RAC. The paper will address the pertinent component which is the installation of RAC on VMware with VMAX3.

Oracle Real Application Clusters (RAC) on VMFS

RAC on VMware can be configured with either Raw Device Mappings (RDMs) or vmdks. For this solution vmdks were chosen to reduce complexity.

As VMware is moving away from RDMs, given the advent of Virtual Volumes (VVols) in vSphere 6, VMFS was used. VMFS has the added benefit of simplified management. Using RAC on VMware requires that certain steps are taken to enable the virtual machines running as RAC nodes to access the same vmdks. Oracle has a clustering technology, Oracle Clusterware5, which contains the intelligence to ensure that two or

5 In 12c, the Oracle Clusterware and Automatic Storage Management (ASM) form the Oracle Grid Infrastructure.

41 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 42: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

more RAC nodes can access the same disk without causing data issues. While VMware will allow multiple VMs to access the same vmdk when used for such technologies as VMware Fault Tolerance (FT) where only one VM is writing, by default it does not permit multiple virtual machines to write to the same vmdk. If such a restriction were not in place, VMware could not guarantee any order of writes coming from the virtual machines which could very easily lead to data corruption and loss.

VMware provides the means to override this protection through the multi-writer flag that is set on a vmdk by vmdk basis. The process for this can be found in VMware KB article 1034165. VMware specifically calls out third-party clustering software like RAC for this type of change. One of the pre-requisites for setting the flag is that the Oracle vmdks designated for the database need to be created as type eagerzeroedthick. This is in line with VMware’s best practices for Oracle databases on VMware.

Oracle Clusterware deployment

Oracle Clusterware and Automatic Storage Management (ASM) are deployed on SRDF/Metro devices and, as previously discussed, without the need for a third site for the voting disks. EMC recommends deploying the Clusterware files, OCR and voting, on their own ASM disk group using “Normal” redundancy, while using “External” redundancy for the other disk groups.

Oracle Extended RAC installation

The following are the basic steps undertaken when configuring Oracle RAC on VMware for this environment. These steps were taken on each of two nodes in the RAC environment. As this is being done on a SRDF/Metro environment, it is by default an Extended RAC configuration. The steps below assume that SRDF/Metro devices have been presented to both ESXi hosts in the HA cluster, after full synchronization.

Note that in the environment in this paper two RAC nodes were used and that they were installed independently and with independent software homes. There are a number of options available when installing RAC nodes, particularly on VMware. Users may choose to install some components on a single node (e.g. OS, disks, etc.) and then create a template from it. Using that template they can create multiple RAC nodes. At that point they may choose to use a shared home for the Oracle binaries. These options are strictly preferences of the user doing the install and do not impact the functionality of the cluster, though they can make patching easier. Create VMFS on each of the devices presented from the VMAX3. There will be some for the OS and binaries and others for the ASM setup for the Oracle RAC database. Though SRDF/Metro makes it perfectly possible to use a shared home for Oracle, in this installation separate homes were configured, providing redundancy for each node independently since each host sees the datastores in use.

Procedure

1. Configure an NTP client for use in the environment.

42 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 43: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

2. Create a VM with Guest OS set to Oracle Linux 4/5/6 (64-bit). Create a single vmdk to hold the OS, and another vmdk to hold the Oracle Application binaries. In this setup, these vmdks reside on separate datastores on SRDF/Metro.

3. Add a second NIC. Be sure both NICs are set to VMXNET3. These NICs should be on VMware networks configured on their own physical adapter.

4. Install the OS and all necessary packages. Note Oracle now offers an E-Business Suite Pre-Install RPM which contains all the necessary packages to run Oracle E-Business Suite.

5. Install Oracle Enterprise Linux, VMware tools and the ASMLIB components. Configure ASMLIB.

6. Configure NTP on the node.

7. Create vmdks for the Oracle database and CRS/voting disks. The configurations may vary. For this environment multiple disks (TDEVs) were created for the cluster files, data, redo, and archive (FRA). All vmdks need to be eagerzeroedthick (EZT), otherwise there will be issues such as an inability to restart the VM. The disks should be assigned to a Paravirtual SCSI controller. Be sure the controller is set to the default of “None” for SCSI Bus Sharing or vMotions will not be possible.

8. Use VMware KB article 1034165 to set the multi-writer flag on the vmdks, allowing more than one node to access the disk.

9. Using fdisk configure a single partition on all the disks. It is important to align the partition on the disk since neither Oracle nor VMware will do this automatically. VMware ensures the VMFS is aligned but not the file systems on vmdks. On the VMAX3, a 128 KB offset should be utilized as in this environment.

10. Use oracleasm to create the ASM disks on one of the hosts. Then use oracleasm to rescan on the second host and discover the ASM disks.

11. Install and configure Oracle Grid Infrastructure 12.1.0.2. There are many prerequisites that must be completed before installation. Oracle uses the Cluster Verification Tool (CVU) to ensure the nodes are ready for installation. The Clusterware install will use a single ASM disk group during installation. Set this disk group to “Normal” redundancy which will ensure multiple voting disks as Oracle automatically determines the number of files based on redundancy. This ASM disk group need not be large as the Clusterware files are small.

12. Create the remaining ASM disk groups using the ASM GUI or ASM CLI, being sure to set redundancy to “External.” Oracle and EMC both recommend using this redundancy due to the superior availability of the VMAX3. The Clusterware disk group is the only one requiring a “Normal” redundancy for previously noted reasons.

13. Install Oracle database binaries on both nodes at once through the installer.

14. Following the various Oracle technical notes, take the following steps:

a. Upgrade the E-Business Suite database from 11g to 12c.

43 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 44: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

b. Convert the E-Business Suite database from file to ASM

c. Upgrade the E-Business Suite database to RAC

Networking

The network configuration used in this environment was limited to two physical NICs on the ESXi hosts. A best practice would be to separate the management network, vMotion network, Oracle public and private networks. Figure 31 shows the configuration with just two NICs:

Figure 31. vSphere networking for Oracle RAC

After the Oracle Applications’ database is converted to RAC, the database administrator will be able to run a successful status check that should yield results similar to Figure 32. It displays the status of an Extended RAC node after installation and conversion.

44 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 45: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 32. Oracle RAC status on production node

VMware Cluster Configuration with SRDF/Metro This section will specifically focus on the best practices when running a vMSC with SRDF/Metro.

Figure 33 shows the recommended cluster configuration for VMware deployments that leverage devices presented through EMC SRDF/Metro with a Witness employed. It can be seen from the figure that VMware vSphere consists of a single VMware cluster. The cluster includes two VMware ESXi hosts with one at each physical data center (referred to here as New York and New Jersey). If site HA is also desired, two or more ESXi hosts could be configured at each site. Also shown in the figure, as an inset, are the settings for each cluster. The inset shows that VMware DRS and VMware HA are active in the cluster and that VM Monitoring is activated.

45 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 46: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 33. Setting vSphere DRS and HA services

vSphere HA

As the main business driver of SRDF/Metro and vSphere Metro Cluster is high availability, it is important to ensure that server resources exist to failover to a single site. Therefore the Admission Control policy of vSphere HA should be configured for 50% CPU and 50% memory. This is demonstrated in Figure 34.

46 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 47: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 34. vSphere HA Admission Control

Both VMware and EMC recommend using a percentage-based policy for Admission Control with HA as it is flexible and does not require changes when additional hosts are added to the cluster.

Heartbeating

vSphere HA uses heartbeat mechanisms to validate the state of a host. There are two different types of heartbeating:

• network (primary)

• datastore (secondary)

If vSphere HA fails to determine the state of the host with network heartbeating, it will then use datastore heartbeating. If a host is not receiving any heartbeats, it uses a fail-safe mechanism to detect if it is merely isolated from its master node or completely isolated from the network. It does this by pinging the default gateway. It is possible to configure additional isolation addresses in case the gateway is down. VMware recommends specifying a minimum of two additional isolation addresses, with each address site local. This is configured in the Advanced Options of vSphere

47 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 48: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

HA using the option name das.isolationAddress.x (‘x’ is incremented for each address):

Figure 35. Adding network isolation addresses for vSphere HA

For the heartbeat mechanism, the minimum number of heartbeat datastores is two and the maximum is five. VMware recommends increasing the number of heartbeat datastores from two to four in a stretched cluster environment. This provides full redundancy for both data center locations. Defining four specific datastores as preferred heartbeat datastores is also recommended. To increase the minimum heartbeat datastores, in the Advanced Options of vSphere HA add a new option named das.heartbeatDsPerHost, depicted in Figure 36.

48 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 49: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 36. Change minimum heartbeating datastores

Once the minimum heartbeat datastores are configured, under “Datastore for Heartbeating” select the radio button “Use datastores from the specified list and complement automatically if needed.” Then select the four specific datastores to use in the configuration. The recommended setup is depicted in Figure 37.

49 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 50: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 37. Modify heartbeat datastore selection policy

Polling time for datastore paths

By default, VMware polls for new datastore paths every 300 seconds. In an SRDF/Metro environment using NMP, EMC recommends changing this to 30 seconds to avoid the need to manually rescan after presenting the R2 devices. The value that requires changing is Disk.PathEvalTime and it must be changed on each ESXi host as demonstrated in Figure 38.

50 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 51: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 38. Changing path evaluation time

All Paths Down (APD) and Permanent Data Loss (PDL)

An additional, important feature that should be addressed when enabling vSphere HA is Host Hardware Monitoring or VM Component Protection. This relates to the conditions All Paths Down and Permanent Data Loss and will now be discussed before detailing affinity rules.

All paths down or APD, occurs on an ESXi host when a storage device is removed in an uncontrolled manner from the host (or the device fails), and the VMkernel core storage stack does not know how long the loss of device access will last. VMware, however, assumes the condition is temporary. A typical way of getting into APD would be if the zoning was removed.

Permanent device loss or PDL, is similar to APD (and hence why initially VMware could not distinguish between the two) except it represents an unrecoverable loss of access to the storage. VMware assumes the storage is never coming back. Removing the device backing the datastore from the storage group would produce the error.

VMCP

vSphere 6 offers some new capabilities around APD and PDL for the HA cluster which allow automated recovery of VMs. The capabilities are enabled through a new feature in vSphere 6 called VM Component Protection or VMCP. When VMCP is enabled, vSphere can detect datastore accessibility failures, APD or PDL, and then recover affected virtual machines. VMCP allows the user to determine the response that vSphere HA will make, ranging from the creation of event alarms to virtual machine restarts on other hosts.

VMCP is enabled in the vSphere HA edit screen of the vSphere Web Client shown previously in Figure 33. Check the box for “Protect against Storage Connectivity Loss” demonstrated in Figure 39.

51 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 52: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 39. Enabling VMCP

Once VMCP is enabled, storage protection levels and virtual machine remediation can be chosen for APD and PDL conditions as shown in Figure 40.

52 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 53: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 40. Storage and VM settings for VMCP

In vMSC Fibre Channel configurations, the Host isolation setting should remain as “Disabled” which means the VMs remain powered on. If iSCSI is being used then VMware recommends setting Host isolation to power off the VMs.

PDL VMCP settings

The PDL settings are the simpler of the two failure conditions to configure. This is because there are only two choices: vSphere can issue events, or it can initiate power off of the VMs and restart them on the surviving host(s).

vMSC recommendations for PDL

As the purpose of HA is to keep the VMs running, the default choice should always be to power off and restart. Once the option is selected, the table at the top of the edit settings is updated to reflect that choice. This is seen in Figure 41.

53 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 54: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 41. PDL datastore response for VMCP

PDL AutoRemove

PDL AutoRemove is a feature that was first introduced in vSphere 5.5. This feature automatically removes a device from a host when it enters a PDL state. Because vSphere hosts have a limit of 255 disk devices per host, a device that is in a PDL state can no longer accept I/O but can still occupy one of the available disk device spaces. Therefore, it is better to remove the device from the host.

PDL AutoRemove occurs only if there are no open handles left on the device. The auto-remove takes place when the last handle on the device closes. If the device recovers, or if it is re-added after having been inadvertently removed, it will be treated as a new device. In such cases VMware does not guarantee consistency for VMs on that datastore.

In a vMSC environment, such as with SRDF/Metro, VMware recommends that AutoRemove be left in the default state, enabled. In an SRDF/Metro environment this

54 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 55: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

is particularly important because if it is disabled, and a suspend action is taken on a metro pair(s), the non-biased side will experience a loss of communication to the devices that can only be resolved by a host reboot.

For more detail on AutoRemove refer to VMware KB 2059622.

APD VMCP settings

As APD events are by nature transient, and not a permanent condition like PDL, VMware provides a more nuanced ability to control the behavior within VMCP. Essentially, however, there are still two options to choose from: vSphere can issue events, or it can initiate power off of the VMs and restart them on the surviving host(s) (aggressively or conservatively). The output in Figure 42 is similar to PDL.

Figure 42. APD datastore response for VMCP

55 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 56: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

If issue events is selected, vSphere will do nothing more than notify the user through events when an APD event occurs. As such no further configuration is necessary. If, however, either aggressive or conservative restart of the VMs is chosen, additional options may be selected to further define how vSphere is to behave. The formerly grayed-out option “Delay for VM failover for APD” is now available and a minute value can be selected after which the restart of the VMs would proceed. Note that this delay is in addition to the default 140 second APD timeout. The difference in approaches to restarting the VMs is straightforward. If the outcome of the VM failover is unknown, say in the situation of a network partition, then the conservative approach would not terminate the VM, while the aggressive approach would. Note that if the cluster does not have sufficient resources, neither approach will terminate the VM.

In addition to setting the delay for the restart of the VMs, the user can choose whether vSphere should take action if the APD condition resolves before the user-configured delay period is reached. If the setting “Response for APD recovery after APD timeout” is set to “Reset VMs”, and APD recovers before the delay is complete, the affected VMs will be reset which will recover the applications that were impacted by the I/O failures. This setting does not have any impact if vSphere is only configured to issue events in the case of APD. VMware and EMC recommend leaving this set to disabled so as to not unnecessarily disrupt the VMs. Figure 43 highlights the additional APD settings.

Figure 43. Additional APD settings when enabling power off and restart VMs

56 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 57: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

vMSC recommendations for APD

As previously stated, since the purpose of HA is to maintain the availability of VMs, VMware and EMC recommend setting APD to power off and restart the VMs. Depending on the business requirements, the 3 minute default delay can be adjusted higher or lower.

If either the Host Monitoring or VM Restart Priority settings are disabled, VMCP cannot perform virtual machine restarts. Storage health can still be monitored and events can be issued, however.

VMware VM/Host Groups and VM/Host Rules

To take full advantage of the HA cluster failover capability in a SRDF/Metro cluster that employs a Witness, it is necessary to create Groups and then Rules that will govern how the VMs will be restarted in the event of a site failure. Setting these up is a fairly simple procedure in the vSphere Web Client. This will allow restarting of VMs in the event of a failure at either New York or New Jersey.

To access the wizards to create Host Groups and Rules, highlight the cluster (SRDF_Metro_Cluster) and navigate to the Manage tab and then Settings sub-tab. This is shown in Figure 44. Note that as required the DRS automation level is already configured as “Fully automated” to permit VMware to move the virtual machines as necessary as previously seen in Figure 33.

57 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 58: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 44. Locating DRS Groups and Rules

For VM/Host Groups, one should create two VM Groups and two Host DRS Groups. In Figure 45 four groups have been created. New_York_VM_Group contains those VMs associated with host 10.108.245.131 and New_York_Host_Group contains that single host. The New Jersey setup is similar.

58 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 59: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 45. Creation of groups for hosts and virtual machines

Hosts and VMs are added respectively to each group and this is seen in Figure 46.

59 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 60: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 46. Adding hosts and virtual machines to appropriate groups

Now that the groups are in place, rules need to be created to govern how the groups should behave when there is a site failure. There are two rules, one that applies to New York and one that applies to New Jersey. The rule New_York_VM_Rule, seen in Figure 47, dictates that the VMs associated with New York (through the group) “should run” on the hosts associated with New York (again through the group) – vice-versa for New Jersey’s VMs. It is important that the condition for both rules is “should run” and not “must run” since this gives flexibility for the VMs to start-up on the other node if needed. Each rule will permit the VMs associated with the failing cluster to be brought up on the two hosts that are part of the site that did not fail, and most importantly, to automatically migrate back to their original hosts when the site failure is resolved. Also note that by default, vSphere HA ignores the rules during failover – if these are not left to ignore (default) then vSphere would not bring up the failed site’s VMs on the surviving host.

60 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 61: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 47. Creation of VM/Host rules for groups

These configurations along with SRDF/Metro Witness will ensure that a site failure will not completely bring down the environment.

Best practices with VMware HA and SRDF/Metro

Follow these best practices when configuring a SRDF/Metro in a campus:

• Configure the front end with a stretched layer-2 network so that when a virtual machine moves between sites, its IP address can stay the same.

61 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 62: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

• Use host affinity rules. Host affinity rules keep virtual machines running in the preferred site as long as the virtual machines can, and only moves the virtual machines to the non-preferred site if they cannot run in the preferred site.

• Use a Witness with SRDF/Metro and not bias to provide the best availability.

Viewing VMAX3 in vSphere When the environment is fully configured, EMC provides the capability to get detailed information about the VMAX3 devices that back the VMware datastores. This is accomplished through EMC Virtual Storage Integrator.

EMC Virtual Storage Integrator

The mapping of the VMware canonical device and VMFS to EMC VMAX devices are critical components when using EMC VMAX-based storage software. To aid in this, EMC provides a plug-in called EMC Virtual Storage Integrator for VMware vSphere, also known as VSI. This free tool, available to download at support.EMC.com, enables additional capabilities to the vSphere Web Client, so that users may view detailed storage-specific information. The VSI Web Client runs as a virtual appliance and a VSI plug-in is installed in the vSphere Web Client and is thus accessible from any browser.

The VSI Web Client provides simple, storage mapping functionality for EMC storage-related entities including datastores, RDMs, SCSI and iSCSI targets. The storage information is displayed within the various panels of the vSphere Web Client.

VSI provides a view at the datastore level and for a more global view, at the host level.

The host level, seen in Figure 48, has important mapping information such as the runtime name of the device that is mapped to a particular datastore, along with the array SID, model, HYPERMAX OS version and pathing ownership.

62 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 63: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 48. VSI host level view

By selecting any datastore, the hyperlink will bring the user to the datastore detail where the SLO, storage group, device ID, SRP, and device type are available, among other fields. An example from the datastore DATA_1 is shown in Figure 49.

63 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 64: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 49. VSI datastore view

Conclusion EMC SRDF/Metro running the HYPERMAX operating system is an enterprise-class technology that dissolves distance by providing active/active access to dispersed VMAX3 arrays enhancing availability and mobility. Using SRDF/Metro in conjunction with VMware and Oracle availability technologies, VMware HA and RAC, provides new

64 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 65: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

levels of availability suitable for the most mission critical environments without compromise.

These technologies provide the basis by which a customer can ensure high availability at both the hardware and software level – through the nature of SRDF/Metro, vSphere HA and Oracle Extended RAC.

References

EMC • Using EMC Symmetrix Storage in VMware vSphere Environments TechBook

http://www.emc.com/collateral/hardware/solution-overview/h2529-vmware-esx-svr-w-symmetrix-wp-ldv.pdf

• Deployment Best Practice for Oracle Database with VMAX3 Service Level Objective Management

https://support.emc.com/docu59498_Deployment-Best-Practice-for-Oracle-Database-with-VMAX3-Service-Level-Objective-Management.pdf

• SRDF/Metro vMSC support VMware KB article

http://kb.vmware.com/selfservice/microsites/search.do?cmd=displayKC&docType=kc&externalId=2134684

• EMC VMAX3 SRDF/Metro Overview and Best Practices

http://www.emc.com/collateral/technical-documentation/h14556-vmax3-srdf-metro-overview-and-best-practices-tech-note.pdf

• Using EMC SRDF Adapter for VMware vCenter Site Recovery Manager

http://www.emc.com/collateral/software/technical-documentation/h10553-sra-vmware-tb.pdf

The following are available on Support.EMC.com website:

• Oracle Databases on EMC Symmetrix Storage Systems TechBook

• VSI Product Guide Product Guide

• Unisphere for VMAX Product Guide

VMware • vSphere Storage ESXi 6.0

http://pubs.vmware.com/vsphere-60/topic/com.vmware.ICbase/PDF/vsphere-esxi-vcenter-server-60-storage-guide.pdf

• vSphere Installation and Setup Guide

65 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 66: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

http://pubs.vmware.com/vsphere-60/topic/com.vmware.ICbase/PDF/vsphere-esxi-vcenter-server-60-installation-setup-guide.pdf

• Virtual Machine Administration Guide

http://pubs.vmware.com/vsphere-60/topic/com.vmware.ICbase/PDF/vsphere-esxi-vcenter-server-60-virtual-machine-admin-guide.pdf

The following are available at the VMware.com website:

• Oracle Databases on VMware Best Practices Guide

• VMware vSphere Metro Storage Cluster Recommended Practices

Oracle

The following are available at support.oracle.com website:

• Oracle Applications Installation Guide: Using Rapid Install Release 12

• Oracle Applications Concepts Release 12

• Oracle E-Business Suite Installation and Upgrade Notes Release 12 (12.2) for Linux x86-64 (Doc ID 1330701.1)

• Oracle Database 12c Upgrade Guide

• Oracle E-Business Suite Release Notes, Release 12.2 (Doc ID 1320300.1)

• Database Initialization Parameters for Oracle E-Business Suite Release 12 [ID 396009.1]

• Using Oracle 12c Release 1 (12.1) Real Application Clusters with Oracle E-Business Suite Release R12.2 (Doc ID 1626606.1)

• Interoperability Notes Oracle EBS 12.2 with Oracle Database 12c Release 1 (Doc ID 1926201.1)

66 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 67: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Appendix A This appendix contains procedures which can be referenced for future use once a vMSC with SRDF/Metro is operational.

SRDF/Metro maintenance

Adding new pairs

If maintenance is required on the existing SRDF/Metro configuration, for example adding new pairs to the group, there are restrictions in the GA release which prevent doing this online. For example, once an SRDF group has Metro pairs, one cannot simply add another pair to the group. The group must first be suspended.6 If it is determined that changes are needed, the following steps should be followed in the vMSC environment. Use of the vSphere Web Client and Unisphere for VMAX is recommended, however it is possible to use command line interfaces such as Solutions Enabler.

Note that during the maintenance procedure, one side of the HA environment is unavailable, i.e. there is no HA. If the business cannot tolerate any potential disruption to the HA environment, it is advisable to create a new SRDF/Metro group with the new pairs. This avoids any downtime for one side of the Metro.

Before beginning the maintenance procedure, be sure to check on which array the bias resides. The bias will always be the R1. This can be determined through Unisphere or Solutions Enabler.

1. If necessary, change the bias to the non-maintenance site.

2. Change DRS Automation to “Manual” to prevent automatic movement of VMs to the R2.

3. Move all VMs from the maintenance side (R2) to the R1 hosts.

4. Unmount the datastores on the R2 ESXi hosts. Although this step is not required, it is recommended to ensure no VMs are still running on the datastores. Note that if any of the datastores are being used for the HA heartbeat, a warning will be shown which can be ignored. In order to avoid this warning, alternative datastores can be specified for the HA heartbeat before unmounting.

5. Delete the masking view for the R2. The devices should be unmapped/unmasked from the hosts before suspending the group.

6. Rescan the R2 ESXi hosts so they no longer see the devices.

7. Suspend the devices in the SRDF group.

6 If expanding a device, however, the pair must be removed after suspension. This is not unique to Metro as any SRDF mode requires the pair to first be dissolved and the R1, R2 expanded independently.

67 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 68: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

8. Add pairs to the SRDF group (NR device, suspended link state) and the R1 and R2 storage groups.

9. Re-establish pairs.

10. Once synchronized (ActiveBias or ActiveActive state) re-create the R2 view.

11. Rescan the R2 ESXi hosts which will automatically discover the datastores and mount them or wait for them to be recognized.

12. Move VMs back to R2 hosts manually and enable DRS or allow DRS to move VMs automatically based on rules.

VM mobility

One of the benefits of vMSC is VMs can be moved from one site to the other by simply relocating compute resources since the virtual device is the same on both sides of the cluster. Although DRS will automatically handle the placement and movement of VMs based upon resources as well as any host rules in place (see VMware VM/Host Groups and VM/Host Rules), it may be necessary to manually relocate VMs. The process of migration is no different in a Metro cluster than a typical VMware cluster. Though migration is a common task documented by VMware, in the interest of completeness it is included here in a series of steps.

1. Start by setting DRS from Fully Automated to Manual so that the VMs will not be re-migrated.

2. Select the VM for migration, and choose “Migrate.”

68 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 69: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

3. Select “Change compute resource only”

4. Select the host in the other metro site.

69 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 70: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

5. Review the network map.

6. Select the priority.

70 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 71: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

7. Complete the migration.

As VMware does not have to change the storage of the VM, the migration completes relatively quickly.

Appendix B – SRDF/Metro with VMware Site Recovery Manager This appendix covers using SRDF/Metro with VMware Site Recovery Manager (SRM) in a stretched storage configuration. It is included here as it is based upon the environment in this paper with minor adjustments to meet the requirements of SRM stretched storage setup. The example below assumes a detailed knowledge of using the SRDF SRA with SRM and therefore will only cover the new stretched storage capability available with VMware SRM 6.1 in conjunction with SRDF SRA 6.1. If additional information on the workings of VMware SRM with the SRDF SRA is required, please refer to the following TechBook: Using EMC SRDF Adapter for VMware vCenter Site Recovery Manager.

71 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 72: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

VMware vCenter Site Recovery Manager 6.1

With the release of VMware vCenter Site Recovery Manager 6.1, VMware adds a new type of functionality to their disaster recovery software, support of stretched storage. At a high level, the VMware SRM software handles the orchestration/automation of disaster recovery between two sites.

In a typical disaster recovery configuration, one site is active while the other is passive, and the distance between those sites might be significant (i.e. hundreds of miles or more). By contrast, in a stretched storage configuration, both sites are active and while the distance between the sites can approach 60 miles or more depending on the network, more commonly the sites are located within a campus (e.g. campus cluster).

What SRM 6.1 offers, in conjunction with the SRDF SRA 6.1, is the same capability it offers today but with a stretched storage deployment. Each of the existing SRM functions is supported: Test, Planned Migration, and Disaster Recovery. The rationale for using SRM in stretched storage may be different than a traditional implementation where the secondary site is passive and at a distance that makes clustering impossible. With stretched storage, SRM may be particularly useful in avoiding manual intervention during site maintenance. SRM, in conjunction with the SRDF SRA, provides complete automation during the planned migration. At a high level this involves vMotioning the VMs from one site to the other, suspending the RDF link, and changing the bias to the other site. After maintenance is complete, reprotection is run, followed again by a planned migration if maintenance is required on the other site.

In a disaster recovery (DR) event, SRM can again complete the tasks necessary to bring up all VMs on the surviving site. What is most beneficial in a SRM stretched storage configuration is of course the active shared storage. An active/active cluster means in a planned migration or DR, the datastores are already mounted and available, saving costly time. This is particularly important in a DR scenario where the recovery time object (RTO) may be very low. As the RTO approaches zero, it is ever more critical to introduce the type of automation SRM offers to avoid human error.

Environment

In order to use the environment detailed in this paper with SRM and stretched storage, two changes are required. Firstly, the SRDF SRA 6.1 does not support the Witness functionality of SRDF/Metro. All SRDF/Metro pairs must use Bias, and therefore the state of the pairs will be ActiveBias. The second requirement is one that all SRM environments share, and that is the need for 2 vCenters, not one. SRM must have a protection and recovery site. With stretched storage those vCenters must also be in Enhanced Linked Mode (ELM).

The details provided in this appendix are based on the environment in this paper, along with the following additions/updates:

• HYPERMAX OS 5977 Q1 2016 SR

72 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 73: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

• SRDF/Metro with Bias

• SRDF SRA 6.1

• Solutions Enabler/Unisphere for VMAX 8.2

• vSphere 6.0 U2 (vCenters, ESXi) in Enhanced Linked Mode using NMP

• VMware SRM 6.1

As mentioned above, in order to use this environment with SRM and stretched storage, the ESXi hosts that comprised the vCenter were split apart and each added to their own vCenter in Enhanced Linked Mode. As this effectively removed VMware HA from the solution, a second ESXi host was added to each vCenter with both environments using the same HA setup previously outlined in the paper (vSphere HA).

To support the second change, the use of Bias and not Witness, the third array was removed from the original configuration which resulted in the SRDF/Metro pairs defaulting to bias. The updated environment is shown in Table 2.

Table 2. Example environment

Virtual Machine Name Model OS & Version CPUs RAM (GB)

Disk

RAC Database Tier Node 1

dsib2233 VMware VM

OEL 6.7 64-bit

4 16 SAN

RAC Database Tier Node 2

dsib2234 VMware VM

OEL 6.7 64-bit

4 16 SAN

Applications Tier 1 dsib0242 VMware VM

OEL 6.7 64-bit

4 12 SAN

Applications Tier 2 dsib0243 VMware VM

OEL 6.7 64-bit

4 12 SAN

Production vCenter NY

dsib2116 [ESXi hosts

dsib1131, 1139]

VMware VM

Win2012 64-bit

2 12 SAN

Production vCenter NJ

dsib2117 [ESXi hosts

dsib1132, 1140]

VMware VM

Win2012 64-bit

2 12 SAN

EMC VMAX3 HK000196700535 VMAX 200K

HYPERMAX OS 5977 Q1

2016 R1

SATA,FC,EFD

EMC VMAX3 HK000196700536 VMAX 200K

HYPERMAX OS 5977 Q1

2016 R2

SATA,FC,EFD

Figure 50 demonstrates the Enhanced Linked Mode (ELM) setup, where both vCenters are visible from a single pane. ELM allows cross-vCenter migrations of virtual machines, and hence why it is required for the stretched storage SRM setup. The way ELM is configured is as such: With vSphere 6 vCenter there are two components – a Platform Service Controller (PSC) and the vCenter itself. The PSC contains the Single Sign-On (SSO) domain. Each vCenter in a SRM setup that supports stretched storage must share a PSC. While there are a number of supported topologies for deployment,

73 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 74: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

VMware recommends that the PSC is separate from either vCenter.7 Please refer to the VMware documentation in the References section for detailed installation instructions of ELM.

Figure 50. Updated vMSC environment for SRM

Figure 51 is an updated visual representation of the environment originally presented in Figure 28. Again, not all hardware components are included.

7 VMware publishes a list of recommended topologies which can be found in KB 2108548.

74 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 75: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 51. Physical/virtual environment diagram for SRDF/Metro with SRM

Configuration

SRDF SRA 6.1

The SRDF SRA version 6.1 is required for stretched storage with SRM. Once the sites are paired in SRM, as depicted in Figure 52, install the SRDF SRA on both SRM servers.

75 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 76: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 52. SRM paired sites

Within a site in SRM, under the Monitor tab and sub-tab SRA, all installed adapters are listed. Note that in SRM 6.1 there is a new row called “Stretched Storage” for each SRA. In Figure 53, one can see that the SRDF SRA 6.1 supports stretched storage. Be aware that if the sites are not paired, the Status row will indicate SRM is unable to find the SRDF SRA at the remote site, rather than the “OK” demonstrated in the figure.

76 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 77: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 53. SRDF SRA 6.1

Stretched Storage - Tags, Categories and Storage Policies

Tag and Category

Configuring SRM proceeds as normal for most inventory mappings, despite the use of stretched storage. Setup the following mappings along with their reciprocals, just as in any SRM configuration:

• Network Mappings

• Folder Mappings

• Resource Mappings

• Placeholder Datastores

The SRM setup to this point, as one can see, is no different than a typical configuration. Normally the next logical step, therefore, is to create the protection group and then the associated recovery plan. Here, however, is where the paradigm changes and important configuration changes are required for stretched storage.

VMware uses VM Storage Policies when setting up the protection groups for stretched storage, not datastore groups which is the normal practice when using the SRDF SRA. Storage policies are most commonly associated with VASA, particular in conjunction

77 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 78: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

with VMware Virtual Volumes (VVols). When used with VASA, storage policies are created based on data services. With SRM, however, these storage policies are tag-based. The first requirement therefore is to create a tag. There are 2 steps involved with creating and applying the tag:

1. Create tag and category

2. Assign newly created tag to SRDF/Metro datastores at protection and recovery site

Only a single tag is used in a stretched storage configuration. When creating a tag, a new category should be created and associated with that tag as in Figure 54.

78 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 79: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 54. Tag and category for SRM stretched storage configuration

Once created, the tag needs to be applied to each SRDF/Metro datastore. This can be done in bulk, by highlighting the vCenter on the left and selecting the Related Objects tab and then Datastores sub-tab, and then completing the 3 easy steps as shown in Figure 55.

79 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 80: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 55. Assign tag to SRDF/Metro datastores

80 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 81: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

The tag should be applied on both the protection site and the recovery site. After the tag is successfully applied to the datastores, a storage profile can now be created.

VM Storage Profile

Each vCenter in SRM must have a separate VM storage policy. The process of creation is the same on each vCenter. Start by accessing the storage policies screen through the VMware menu “Policies and Profiles.” Steps 1 through 4 are demonstrated in Figure 56. Select the protection vCenter, a name and a description. In step 3 the storage profile is defined by a tag-based rule, in this case the tag previously created in Figure 55. In step 4 select Next to move to the next screen.

81 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 82: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 56. Creating a Storage Policy - Steps 1-4

In step 5 in Figure 57 the wizard will list all the compatible datastores. All previously tagged datastores should appear as compatible.

82 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 83: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 57. Creating a Storage Policy - Step 5

After each storage profile is created, a final mapping is required in SRM. If, as in this case, the storage profiles have different names then a manual mapping is required. The mapping appears in Figure 58. If the mapping does not exist, SRM will be unable to fail over correctly.

Figure 58. Create Storage Policy Mapping

This constitutes the components of the SRM setup. In order for a VM to be part of a protection group, however, it must be assigned the recently created storage profile.

83 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 84: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Applying a Storage Policy to a VM

Since a SRM stretched storage protection group relies on storage policies to decide which VMs to include in a protection group, it is necessary to apply that storage policy to the VMs. This is a relatively straightforward process which can be accomplished in any number of screens in vSphere. Figure 59 shows the 3 steps necessary to apply the storage policy to VM dsib0242.

In step 1 highlight the VM, select the Manage tab and Policies sub-tab. Here choose the “Edit VM Storage Policies” button which will bring up another dialog box. In step 2 use the drop-down box and select the newly created storage policy and select “Apply to all.” In step 3 the policy is applied to all aspects of the VM. Repeat this for the other VMs at the protection site. This process should also be repeated on the recovery site, applying the storage policy created on the recovery site to the VMs running there. This will ensure those VMs will be included in the protection group when a reprotect is run after a planned migration.

84 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 85: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 59. Applying a storage policy to a VM

It is a best practice to create device groups for those devices involved in the SRM stretched storage configuration. Failure to create the groups may result in configuration errors in the protection group for the VMs. Note that consistency groups are not supported with the SRDF SRA 6.1.

Stretched Storage - Protection Group

The protection group for stretched storage is created in the same manner as a traditional protection group. Here are the 4 steps:

85 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 86: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Step 1 - Name and location

Type in a name and description for the protection group as in Figure 60.

Figure 60. Protection group creation - step 1

Step 2 - Protection group type

In the second step choose the direction of protection and then select “Storage policies” which is the group type for stretched storage. This is demonstrated in Figure 61.

Figure 61. Protection group creation - step 2

86 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 87: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Step 3 - Storage policies

When the storage policies type is selected in step 2, step 3 will allow for selection of the previously created storage policy. Check the box as in Figure 62.

Figure 62. Protection group creation - step 3

Step 4 - Review

Step 4 is a review screen where the selections can be double-checked. Once satisfied, select Finish and complete creation. Step 4 is seen in Figure 63.

87 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 88: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 63. Protection group creation - step 4

Stretched Storage - Recovery Plan

The recovery plan for stretched storage is created in the same manner as a traditional recovery plan. Here are the 5 steps:

Step 1 - Name and location

Type in a name and description for the recovery plan as in Figure 64.

Figure 64. Recovery plan creation - step 1

88 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 89: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Step 2 - Protection group type

In the second step choose the recovery site. This is demonstrated in Figure 65.

Figure 65. Recovery plan creation - step 2

Step 3 - Protection groups

From the drop-down, select the “Storage policy protection groups.” This will result in showing the previously created protection group. Check the box, as in Figure 66, and move to the next step.

Figure 66. Recovery plan creation - step 3

Step 4 - Test networks

In a recovery plan there is an additional step to setup test networks. Leave the mapping to Auto* for all recovery networks. In this example in Figure 67 there are 2 networks.

89 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 90: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 67. Recovery plan creation - step 4

Step 5 - Review

Step 5 is a review screen where the selections can be double-checked. Once satisfied, select Finish and complete creation. Step 5 is seen in Figure 68.

Figure 68. Recovery plan creation - step 5

The environment is now ready for testing, planned migration, or disaster recovery.

Stretched Storage - Known Issue

There is a known VMware bug with cross-vCenter migrations that impact planned migrations with stretched storage on SRM. Although there is no impact to the test functionality, if a test is run SRM will warn the user that if a planned migration is run, it will fail.

The bug concerns free space in the datastore. Before SRM vMotions a VM during a planned migration, it checks whether the shared datastore has enough space for 2x the size of the vmdks (in other words another copy). If there is insufficient space, the vMotion will not proceed and the planned migration will fail. As this is shared storage VMware should not be conducting this test. If a test is run, the following warning in Figure 69 will be issued.

90 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 91: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 69. VMware bug - insufficient disk space

VMware has no plans to address this issue so it is critical that the datastores being used in the SRDF/Metro/SRM environment have sufficient space beyond the 2x size of the vmdks.

Cross-vMotion - Known Limitation

This limitation concerns the ability to vMotion a VM across vCenters, also known as a cross vCenter vMotion. The issue arises if the VM to be vMotioned has vmdks in more than one shared (e.g. SRDF/Metro) datastore. When the vMotion is attempted, VMware will fail to recognize the remote cluster/ESXi hosts as compatible, despite the fact that all datastores are shared.

VMware indicates this is as designed. vSphere will only allow you to migrate a VM (compute resource) if it is on a single datastore. In the case of multiple datastores the computation is too difficult and therefore vSphere cannot process the request. In order to do the vMotion, therefore, the user must select “Change both compute resource and storage” when doing a cross vCenter vMotion with multiple datastores, even if those datastores are shared (SRDF/Metro). This means that when migrating from one vCenter to the other, the user must employ the advanced mapping capability in the migrate wizard to map each vmdk to a target datastore that is the same as the source datastore.

Fortunately this issue does not arise in SRM when doing a planned migration, but many customers do use cross vCenter vMotion to distribute resources across their SRM environment so it is important to be aware of this limitation.

SRDF Adapter Utilities 6.1

To aid in managing the XML files associated with the SRDF SRA 6.1, EMC offers the SRDF Adapter Utilities 6.1 (SRDF-AU). The SRDF-AU 6.1 supports SRDF/Metro stretched storage configuration in SRM 6.1. This section will discuss SRDF-AU only in relation to SRDF/Metro, but detailed product documentation can be reviewed here.

The SRDF-AU is installed on the Windows vCenter host. While it is possible to install it on one site (typically recovery), EMC recommends installing SRDF-AU on both the protection and recovery sites for redundancy. Once installed, the SRDF-AU is available as an icon in the Home page of the vSphere Web Client which is shown in Figure 70.

91 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 92: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 70. EMC SRDF Adapter Utilities

While SRM supports the use of the vCenter appliance (VCSA), the SRDF Adapter Utilities do not. Therefore if use of the SRDF-AU is desired8, the vCenters must be installed on Windows.

As mentioned, the SRDF-AU provides a GUI interface to modify the XML files that the SRDF SRA utilizes. In order to query information about the SRDF pairs, SRDF-AU requires a connection to an SMI-S Provider for the recovery site. That SMI-S Provider can be a part of the same Solutions Enabler installation that is used as an SRM array manager.

In the Settings tab in Figure 71, supply this information, testing both the vCenter and SMI-S connection before saving. Note for SRDF/Metro it is unnecessary to supply an SMI-S Provider to the protection site as consistency groups are not supported with the SRDF SRA 6.1.

8 The SRDF-AU is an optional software and is not required by the SRDF SRA.

92 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 93: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 71. SRDF-AU Settings

The SRDF-AU offers the following tabs:

• Global Options – used to change values in the EmcSrdfSraGlobalOptions.xml file.

• FailoverTest/GoldCopy – used to set pairs for the R2 device.

• RDF Device Masking – used to configure masking that the SRDF SRA can perform. SRDF/Metro does not support this functionality.

93 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 94: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

• Test Replica Masking – used to configure masking and unmasking of test devices.

• Create CGs – used to create consistency groups. SRDF/Metro does not support this functionality.

In stretched storage the most useful of these tabs is the FailoverTest/GoldCopy. It eliminates the need to manually pair the R2 devices with TimeFinder devices. Any SRDF/Metro pair will show an SRDF Mode of “Active” as in Figure 72.

Figure 72. FailoverTest/GoldCopy tab

Under the TimeFinder Replications sub-tab one can set the appropriate replication type and then run Auto Set Replicas which will apply all available TimeFinder devices to the appropriate R2. An example is provided in Figure 73.

94 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC

Page 95: Using SRDF/Metro in a VMware Metro Storage ... - china.emc… · Executive summary The EMC® ™VMAX family provides disaster recovery and mobility solutions through its remote replication

Figure 73. TimeFinder Replications - Auto Set Replicas

After setting the replicas, the file can be saved to the SRDF-AU default location of C:\ProgramData\EMC\SRAUtilities\<user> on the installed system. Once saved the file can then be downloaded to a local directory if desired. Note that as the SRDF-AU has no direct relationship with the SRDF SRA, the files it modifies are not those used by the SRDF SRA. It is still necessary to copy any modified files with the SRDF-AU over to the SRDF SRA location of C:\ProgramData\EMC\EmcSrdfSra\Config in order for the SRDF SRA to use it during any SRM function.

95 Using SRDF/Metro in a VMware Metro Storage Cluster running Oracle E-Business Suite and 12C RAC